| 1 | Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. |
| 2 | Up to 5.5 KW (7.5 HP) & head up to 120 mtr. |
| 3 | Up to 5.5 KW (7.5 HP) & head above 120 mtr. |
| 4 | 7.5 KW (10 HP) & head up to 120 mtr. |
| 5 | 7.5 KW (10 HP) & head above 120 mtr. |
| 6 | 9.3 KW (12.5 HP) & head up to 120 mtr. |
| 7 | 9.3 KW (12.5 HP) & head above 120 mtr. |
| 8 | 11 KW (15 HP) & head up to 120 mtr. |
| 9 | 11 KW (15 HP) & head above 120 mtr. |
| 10 | 13 KW (17.5 HP) & head up to 120 mtr. |
| 11 | 13 KW (17.5 HP) & head above 120 mtr. |
| 12 | 15 KW (20 HP) and above, head up to 120 mtr. |
| 13 | 15 KW (20 HP) and above, head above 120 mtr. |
| 14 | Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. |
| 15 | 3 core 4.0 Sq.mm |
| 16 | 3 core 6.0 Sq.mm |
| 17 | 3 core 10.0 Sq.mm |
| 18 | 3 core 16.0 Sq.mm |
| 19 | S & F of Star delta Starter with MCB, Main and Aux Contactor, O/L Relay, L/R Selector Switch,3 Indicating lamps, Start-Stop Push Button ,Control MCB with panel with all accessories with following rating |
| 20 | 18.5 KW |
| 21 | 22 KW |
| 22 | 30 KW |
| 23 | Providing & Fixing of IP 51 CT operated direct reading type flush mounting Ampere meter of Moving Iron type of class 1.5 accuracy on existing panel as per PWD specification for electrical Works, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 24 | Below 500 A |
| 25 | Above 500 A |
| 26 | Providing & Fixing of (up to 500) V range Volt meter moving iron AC voltmeter of class 1.5 accuracy as per IS : 1248 on existing panel as per PWD specification for electrical Works, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 27 | Analog type ( 96 mm x 96 mm ) flush mounting |
| 28 | Providing & Fixing of thermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 29 | 20 to 33 Amp |
| 30 | 24 to 40 Amp |
| 31 | 36 to 60 Amp |
| 32 | P & F of 240 / 415 V Electronic ON - OFF Timer 3 -30 Sec / 12 - 120 Sec including making Connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 33 | Providing & Fixing of ISO certified company made 240/415 V porcelain kitkat fuse (/HBC type) as per PWD specification for electrical Works conforming to IS:2086,1983 on existing board/ sheet including making connections with lugs, testing etc. as required . Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 34 | 100 A ,415 V |
| 35 | 200 A , 415 V |
| 36 | 320 A , 415 V |
| 37 | Supply & Installation of single phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. |
| 38 | Up to 2.0 KW |
| 39 | Above 2.0 KW |
| 40 | Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. |
| 41 | 10.0 Sq.mm, 4 core |
| 42 | 16.0 Sq.mm, 4 core |
| 43 | 25.0 Sq.mm, 3.5 core |
| 44 | 35.0 Sq.mm, 3.5 core |
| 45 | Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type Non Return Valves (NRV) of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. Epoxy (Non-Toxic & suitable for drinking water) applied on body, cover and disc inside and outside . Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food grade quality) ,Shaft of SS- AISI- 410 ,Hinge Malleable cast iron / SS AISI 316 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, Gasket EPDM/NBR ,Nut-Bolt as per IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 46 | 80 mm dia |
| 47 | 100 mm dia |
| 48 | 125 mm dia |
| 49 | 150 mm dia Please Enable Macros to View BoQ information |