| 1 | Demolation Bricks Tiles (laid flat or on Edge) or brick tiles in floor, roof, channels,kerbs, Aprons, etc.(each layer) all as specified and directed |
| 2 | Demolation mud in Roofs, any thicknes, including plastering and lapping (weather full thickness Removed or only a part there of ) all as specified and directed |
| 3 | Removed Demolished materials exc 1.5 km and Deposting where as Directed at Above the Starting point all as specified and directed |
| 4 | M & L for removal of plants ( area with in n exc 0.50sqm) growth by injection with chemical glyphosphate solution (4 % concentration) @ 20 ml or till refuse by cutting or injection in stem of plants or roots at 30 mm. The area shall then be sprayed with solution 25 ml glyphosphate (4% conc) diluted with 1 ltr of water, including taking out roots from roof / brick work and making good the disturbed surface with plaster and PCC 1 :2:4 type B0 and disposing the rubbish from site (MOD land) of upto G+ 5 storey height complete and as specified |
| 5 | M&L for Cement Concrete 1:2:4 type B1 (Using 12.5mm graded stone aggregates) on roof padding surface finshed even and smooth without using extra cement complete and as specified |
| 6 | M&L for 15mm average thick (average) rendering in cement mortar 1:4 using WPC (@ 3% of cement wt.) on roof surfaces & finished even and smooth with using extra cement in any position upto G+3 storey bldg complete all as specified. Note:- cost of WPC is included. |
| 7 | M&L for applying a coat of bituminous primer conforming to IS - 3384 @ 0.50 Litres/sqm on prepared surfaces of plaster and applying APP based polymeric membrane with plane slate finish @ 4.00 Kg/Sqm and minimum 3mm thick reinforced with polyester non woven fabric and sealing joints by torch application including demolition of existing upto G+5 storey bldg complete all as specified and directed.Note for item Nos 07: (a) The work shall be executed through authorised applicator of manufacturer only.(b) Authrised Applicator shall be approved by GE before starting of work.(c) All materials shall be procured directly form manufacturer. The purchase voucher shall be produced to the Engineer-in-Charge for his verification of material.Engineer-in-Charge shall deface the original purchase vouchers.(d) MOU with authorized applicator will be submitted by contractor within 7 days after opening of Financial Bid.(d) A guarantee amount of 2.5% of contract of work done for item Nos 07 of BOQ will be retained for 10 years of the completion of work. |
| 8 | M&L for applying two coat of silver Shield BITUMINIOUS paint on app membrane complete all as specified and directed by Engr-in-Charge. |
| 9 | Dismatling Water tanks and Removing to store nexc 500 Ltrs Cpacity |
| 10 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. PVC water tanks of exc 250 litres and n.exc 500 litres capacity of any condition or type incl complete all as specified and directed. |
| 11 | S&F 500 ltr capacity rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position with 20mm Ball brass valves,high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule Minimum wt 20mm-210grm and s&f in repair 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed incl Dismantling of PVC water tanks of exc 250 litres and n.exc 500 litres capacity of any condition or type incl complete all as specified and directed. |
| 12 | S&F in repair stop valve cast copper alloy screw down high pressure with crutch or butterfly handel screwed both ends for 20mm dia iron pipes or for unions and fixed complete all as specified and directed by Engineer-in-Charge. |
| 13 | S/F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, soil, waste, vent pipe in any length with or without ears ,110mm bore complete. |
| 14 | S&F for PVC (SWR) bends & tee any radius, 110 mm bore complete. |
| 15 | Demolition of brick work built in cement mortar in any description and position, upto G+5 storey bldg complete all as specified.. |
| 16 | Brick work with old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 (1 cement : 6 coarse sand), upto G+5 storey bldg complete all as specified. |
| 17 | All as per serial item No 9 but except bricks, all as specified. (Servicable bricks retrieved from Serial Item No 08 shall be used).upto G+5 storey bldg complete all as specified. |
| 18 | Taking down cement plaster in any thickness from brick or stone etc including raking out joints, hacking for key, scrubbing down with water etc upto G+5 storey bldg complete all as specified. |
| 19 | M&L for 15 mm thick rendering in cement mortar on fair faces of brick work or concrete surfaces, applied in two layers i.e.. Ist layer of 10 mm thick rendering in cement mortar (1:6 ) and 2nd (top) layer of 5 mm thick rendering in cement mortar (1:4 ) mixed with WPC finished even and fair etc complete all as specified and directed.(Note:- WPC shall be measured and paid separately.) |
| 20 | M&L for Newly plastered or unplastered wall surface and apply 2mm thick wall care putty for smooth surface and applying two coats of weather coat/apex paint on walls/ceilings complete all as specified and directed. |
| 21 | M & L Providing, cement concrete in kerbs, coping to top of wall, rounded or chamfered on edges type C 0 1:3:6 (12.5mm graded stone aggegate) including demolition complete all as specified and as directed |
| 22 | Supply only liquid water proofing compound complete all as specified and directed. |
| 23 | Schedule of Credit Please Enable Macros to View BoQ information |