| 1 | SH:-EARTH WORK) |
| 2 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m |
| 3 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 4 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 5 | SH:-PLAIN CEMENT CONCRETE WORKS:-Providing and laying in foundations and plinth cement concrete 1 : 3 : 6 (1 cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 6 | Providing and laying in foundations and plinth cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering. |
| 7 | SH:-RCC WORKS:-Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in :b) 1 : 1/2 : 3 (1 cement : 1/2 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 8 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.b) 1 :1/ 2 : 3 (1 cement :1/ 2 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 9 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.b)1 :1/ 2 : 3 (1 cement :1/ 2 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 10 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).b)1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size). |
| 11 | Reinforced cement concrete work in stair cases (excluding landing) except spiral cases including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface, preparing of the top surface and finishing, nosing upto floor two level but excluding the cost of centring, shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size). |
| 12 | Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with 1 : 2 : 4( 1 cement: 2 coarse sand : 4 stone aggregate 20 mm nominal size). |
| 13 | Reinforcement of RCC work including bending, binding and placing in position complete.b) Cold twisted bars. |
| 14 | Centring and shuttering including strutting, propping etc and removal of form work for :a) Foundation, footings, bases of columns etc. and mass concrete. |
| 15 | b) Column, pillars, posts and struts etc. |
| 16 | c) Lintels, beams, girders, bressumers and cantilevers etc. |
| 17 | d) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
| 18 | e) in Stair case |
| 19 | SH:-BRICK WORKS:-Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand). |
| 20 | Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level. |
| 21 | Half brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand). |
| 22 | Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level. |
| 23 | SH:-WOOD WORKSProviding approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position. |
| 24 | Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including aluminium butt hinges with necessary screws. |
| 25 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections ofapproved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P.brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) :a)Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)1868,Minimum anodic coating of grade SC 15) |
| 26 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separatelya)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 27 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge. (Cost of aluminium snap beading shall be paid in basic item)a)With float glass panes of 4.0 mm thickness. |
| 28 | Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size). |
| 29 | Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete.a) 300 x 16 mm |
| 30 | Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete.a) 300 x 10 mm |
| 31 | a) 250 x 10 mm |
| 32 | Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete.a) 125 mm |
| 33 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws. |
| 34 | SH:-Flooring:-Providing and laying vitrified floor tiles in defferent size(Thickness to be specified by themanufacturer) with water absorption less then 0.08% and confirming to IS:15622 of approved make in all colours and shade laid on 20mm thick cement mortor1:4 (1cement 4 coarse sand including grouting the joint with white cement and matching pigment etc. complate. |
| 35 | White glazed tiles 5mm.thick in flooring, skirting, risers of step and dado in 12 mm thick cement plaster 1 : 3(1 cement: 3 coarse sand) painted with white cement slurry. |
| 36 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 37 | Chequrred terrazzo tiles 22 mm thick with marble chips of sizes upto 6mm in floors on 25 mm thick bed mortar 1 : 3 (1 cement : 3 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete: |
| 38 | SH:STEEL WORK:-Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete. |
| 39 | SH:FINISHING:-15 mm cement plaster 1 : 4 (1 cement : 4 fine sand) on the rough side of single or half brick wall. |
| 40 | 12 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
| 41 | Providing two coats of acrylic based wall putty/ wall filler of Asian Paits/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing allthe loosely adhering material from the wall/ ceiling surface with the halp of emery stone, puttyblade or wire brush, moistening the wall with the help of sufficient quantity of clear water asspecified and directed by the department |
| 42 | Applying one coat of distemper primer of approved brand and manufacture on wall surface. |
| 43 | Distempering (two or more coats) with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade. |
| 44 | Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete. |
| 45 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade. |
| 46 | SH:-SANITARY WORKS:-Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required.a) Long Pan patten WC Pan |
| 47 | Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required.a) Flat back wash basin size 550x400 mm with single 15 mm CP brass pillar taps of heavy quality. |
| 48 | Providing and fixing in position 32 mm dia galvanized steel telescopic flush pipe complete including cutting and making good the walls and floors. |
| 49 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes.a) 100 mm dia |
| 50 | Providing and fixing sand cast iron heel rest sanitary bend.a) 100 mm dia |
| 51 | WATER SUPPLY (EXTERNAL WORKS):-Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work).d) 32 mm nominal bore |
| 52 | Providing and filling sand all round GI pipes in external work.d) 32 mm dia pipe |
| 53 | WATER SUPPLY (INTERNAL WORKS):-Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work).a) 15 mm nominal bore |
| 54 | Providing and fixing brass bib cock of approved quality.a)15 mm nominal bore |
| 55 | Providing and fixing brass stop cock of approved quality.a) 15 mm nominal bore |
| 56 | Providing and placing on terrace (at all floorlevels) polythylene water storage tank IS:12701 marked with cover and siutable locking arrangement and making necessary holes for inlet,outlet and over flow pipe but with out fitting and base support for tank |
| 57 | SH:-DRAINAGE:-Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete. |
| 58 | SH:-ROOFING:-Providing and fixing on wall face C.I. rain water pipe including filling the joints with spun yarn soaked in neat cement slurry and cement mortar 1 : 2 ( 1 cement : 2 fine sand).b) 100 mm diameter pipe |
| 59 | Providing and fixing M.S. Holder bat clamps of approved design of C.I. or S.C.I. pipes embedded in and including cement concrete block 10 cm x 10 cm x 10 cm of 1 : 2 : 4 mix (1 cement : 2 coarse sand: 4 stone aggregate 20mm nominal size) including cost of cutting holes and making good the wall etc.b) 100 mm diameter |
| 60 | Providing and fixing on wall face C.I. accessories for rain water pipes including filling the joints with spun yarn soaked in neat cement slurry and cement mortar 1 : 2 ( 1 cement: 2 fine sand).(A) CI Plain bendb) 100 mm diameter |
| 61 | (B) CI head flat or corner type bend :b) 100 mm diameter |
| 62 | (C) CI Plain shoes :b) 100 mm diameter |
| 63 | Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design. |
| 64 | Constructing brick masonry manhole with 2nd class bricks in cement mortar 1 : 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design.a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg). |
| 65 | Sh-Miscellenious:-Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth. |
| 66 | Sh-Internal ElectrificationSh-MAIN DISTRIBUTION BOX (MDB)3 Phase Digital Energy Meter, 63A (Three phase kwh meter 63A), Model : EC350, Make : Hager |
| 67 | SUB-HEAD -III(EARTHING):-Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 68 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 69 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 70 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 71 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 72 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/cable as required. |
| 73 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 74 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.a)Group-C |
| 75 | Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 76 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm LS insulated copper conductor single core cable for loop earthing as required |
| 77 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a)2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. |
| 78 | SUPPLYING & FIXING:-Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.a)1 or 2 Module (75 mmX75 mm) |
| 79 | b)3 Module (100mmX75mm) |
| 80 | c)4 Module (125mmX75mm) |
| 81 | d)6 Module (200mmX75mm) |
| 82 | e)8 Module (125mm X 125mm) |
| 83 | f)12 Module (200mmX150mm) |
| 84 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 85 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 86 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 87 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 88 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 89 | INSTALLATION & TESTING :-Erection of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS lamps per fitting, complete with all accessories including connection etc. as required. |
| 90 | Supplying and fixing 5 amp ceiling Fan including connection with Accessorise as required. |
| 91 | MAIN DISTRIBUTION BOX (MDB):-Providing and fixing 250 A rating ,25kA breaking capacity, TP MCCB with thermomagnetic release and terminalspreaders in existing cubicle panel board including drilling holesin cubicle panel, making connections, etc. as required. (a) 4 way (4 + 12), Double door Please Enable Macros to View BoQ information |