Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Taking down chowkat or frame with shutters (without taking shutter from the frame) exceeding 1.5sqm and not exceeding 4.00 sqm each complete all as specified and directed. |
| 2 | Taking down cement plaster on brick walls or stone walls of any description etc including raking out joints, hacking for key, scrubbing down with water etc, rubbish off the premises, complete all as specified and directed. |
| 3 | Demolition of cement concrete (unreinforced) of any description and in any position not specifically provided for, complete all as specified and as directed. |
| 4 | Demolition of brick work or stone masonay built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework and precast concrete articles and removal of debris/rubbish off the premises etc complete all as specified and directed. |
| 5 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and as directed |
| 6 | Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in any type of soil, complete all as specified and directed. |
| 7 | Excavation in trenches n exc 1.50m wide and n exc 1.50m in depth for foundation etc or for shaft wells, cesspits manholes pier holes etc n. exc 10 sqm on plan and n. exc 1.5m in depth and getting out in any type of soil, complete all as specified and directed. |
| 8 | Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed. |
| 9 | Removing excavated material (soil) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 10 | PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified. |
| 11 | PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified. |
| 12 | PCC 1:2:4 type B-0 ( using 12.5mm graded crushed stone aggregate) padding as roof, surface finished even and smooth without using extra cement, complete all as specified and directed. |
| 13 | RCC M-25 (Design mix) as in foundations including rafts, footings, foundations beams, plinth beams, bases for columns and basement slabs etc complete all as specified and directed. |
| 14 | RCC M-25 (Design mix) as in columns, pillars, piers, posts and struts etc complete all as specified and directed. |
| 15 | RCC M-25 (Design mix) as in beams, cantilever, bressummers, lintels over 1.50m span complete all as specified and directed. |
| 16 | RCC M-25 (Design mix) as in Slabs supported on walls, beams and columns in floors roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed |
| 17 | Hard core of broken stone or boulders of guage n. exc 63mm, deposited, spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surface, complete all as specified and directed. |
| 18 | Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15cm thick, spread, levelled and rammed including watering, complete all as specified and directed. |
| 19 | Brick work with fly ash (Old Size bricks) sub class 'B' bricks straight or curved on plan, exceeding 6m mean radius with old size bricks, built in cement mortar 1:6, complete all as specified and as directed. |
| 20 | Brick work with sub class 'B' bricks straight or curved on plan, exceeding 6m mean radius with old size bricks, built in cement mortar 1:4, complete all as specified and as directed. |
| 21 | Cutting holes for inserting angle iron/Tee into brick/ stone walls into or brickwall not exc 150 sqcm into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required, complete all as specified and as directed. |
| 22 | 5mm thick rendering on concrete surface of ceiling, chajjas, soffits of slabs etc. in CM 1:3 finishing the surfaces even and smooth without using extra cement, complete all as specified and directed. |
| 23 | 10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 finished the surface even and smooth without using extra cement, complete all as specified and directed. |
| 24 | 10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 finished the surface even and smooth without using extra cement including preparation of new plastered surfaces of walls and applying two coats of white wash, complete all as specified and directed. |
| 25 | 15mm thick rendering cement plaster in two layers (10+5mm) on fair faces of brick work or concrete surfaces in cement mortar (1:4) mixed with WPC finished even and smooth without using extra cement & applying two coats of cement base paint, complete all as specified and directed. |
| 26 | 15mm thick rendering cement plaster in two layers (10+5mm) on fair faces of brick work or concrete surfaces in cement mortar (1:4) mixed with WPC finished even and smooth without using extra cement complete all as specified and directed. Note: WPC shall be measured and paid for separately. |
| 27 | 20mm thick cement plaster in cement mortar 1:4 on concrete surfaces, finished even and smooth using WPC liquid as per manufacturer instruction @ 0.200 ltr in 50 Kg of cement, complete all as specified & directed. |
| 28 | 10mm thick rendering on fascia / edging / ceiling of Chajjas, roof projections etc, making the edges in line, in true shape in CM 1:3 and finishing the surface without using extra cement, complete all as specified and directed. |
| 29 | Supply only liquid water proofing compound, complete all as specified and directed. |
| 30 | Preparation of surfaces and applying first coat of fiber reinforced elastomeric liquid water proofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibers with Sun Reflective Index (SRI) of 100-110, having minimum elongation of 300%, tensile strength of 2.9 Mpa and shall have cracks bridging ability upto 2.5mm and shåll resist 10 bars of hydrostatic pressure & reduce surface temperature upto 10 degree Celsius with 33% dilution of priming coat. Laying of fiber mesh of 0.3mm thickness weave in leno pattern having 45 gsm/sqm and pasting it properly with overlap of 50mm and allow it to dry, applying second of undiluted coat @ 0.45 Itr/sqm. Applying third and final coat undiluted @ 0.45 ltr/sqm complete application to be done by the manufacturer or authorised applicator, complete all as specified and directed. |
| 31 | Pressed steel frames for doors/windows of size size 125x60 mm (1.25mm thick MS sheet) with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, duly filling of cement concrete 1:3:6 type C-0 (using 12.50 mm graded crushed stone aggregate) to back of chowkhats, including two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 32 | Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ceosetory windows & other Frames/chowkhat of size 50x100mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 33 | 35mm thick factory made single extruded WPC (Wood Polymer Composite) CNC cutting solid plain flush door shutter comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, WPC to be finished with UV coating minimum 14 microns thick of approved design, complete all as specified and directed. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately). |
| 34 | 35mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, covered with decorative face veneer with lipping/frame to match, complete all as specified and directed. |
| 35 | 35mm thick, 2nd class hardwood (Sal/ Hollock) factory made glazed and skeleton shutters, open rebated and prepared to receive glass or gauge,etc., edges of framing plain, divided into squares with plain chamfered or rounded, mitred and rebated sash bars, any numbers, fitted with cut & mitred beads for securing gauge sizes of members of shutters as specified in SSR Part-I Section-8, clause 8.24 (a) for door shutter supplying and fitted to chowkats, complete all as specified and directed. |
| 36 | Box type Steel windows comprised of tubular frame and shutters made out of 1.25mm thick MS steel tube factory made with double side shutters wire gauged shutter & glass glazed shutter with side hung shutters with steel handle and steel peg stay dovetailed or welded including 2 Nos tower bolts 150mm long for each leaf and 10mm square bar grills at spacing as shown on drg welded to FI frame work, including other fittings, hinges, handles, tarred hold fasts, PCC blocks (1:2:4 type 12.50mm graded crushed stone aggregate) including two coats of synthetic enamel paint over a shop coat of red oxide primer etc. all as shown on drg No CEPZ /TD-354/09 sheet 1/3 to 3/3, complete all as specified and directed. |
| 37 | 4mm thick non-asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws fixed in T-grid/cross-T/Wall angle/level clip & suspenders of standard galvanised sections, complete all as specified and directed. |
| 38 | 300mm size aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy, complete all as specified and directed. |
| 39 | 250mm long stainless steel, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts, complete all as specified and directed. |
| 40 | 100mm long, mild steel cold rolled butt hinges, medium weight, complete all as specified and directed. |
| 41 | 100mm long, stainless steel butt hinges, complete all as specified and directed. |
| 42 | 200mm long, aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed. |
| 43 | 150mm long, stainless steel tower bolts of extruded section, complete all as specified and directed. |
| 44 | 150mm long, extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and directed. |
| 45 | 150mm long, stainless steel handles, fabricated type extruded section ISI marked, complete all as specified and directed. |
| 46 | Floor door stopper of stainless steel body and tongue, anodised, 140mm length of cover plate with hard drawn steel spring, fixed in floor, complete all as specified and directed. |
| 47 | Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tacks or galvanised steel wire staples, fixed in repairs, complete all as specified and directed. |
| 48 | Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples,complete all as specified and directed. |
| 49 | 3mm thick sheet glass ordinary quality, and glazing with oil putty or fixed with bead/glazing pins in squares n.exc 0.50 Sqm in each pane, complete all as specified and directed. |
| 50 | Pre-painted galvalume aluminium zinc coating GI based (AZ150) corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified and directed. |
| 51 | Pre-painted galvalume aluminium zinc coating GI based (AZ150) plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified and directed. |
| 52 | Rolled mild steel as in roof trusses (framed),trussed, purlins, crane girders, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W (Gde-E-250) quality-A, complete all as specified and directed. |
| 53 | Rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe 410-W (Gde-E-250) quality-A, complete all as specified and directed. |
| 54 | Rolled mild steel joist, channel, angle, or tee sections for false ceiling drilled and countershank for screw, including bending and welding angles as necessary conforming to Fe.290.Gde-E-165, complete all as specified and directed. |
| 55 | MS TMT bars 10mm dia and over cut to length, bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not les than 0.9 mm dia or securing with clips quality conforming to complete all as specified and directed. |
| 56 | MS TMT bars bars 5mm dia and over as in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified & directed. |
| 57 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, finishing the concrete surfaces rough, complete all as specified and directed. |
| 58 | Formwork to sides of pillars, posts, struts, piers, columns, and stanchions, square, rectangular or polygonal in shape, finishing the concrete surfaces rough, complete all as specified and directed. |
| 59 | Formwork to sides and soffits of floor or roof beams, haunching, lintels, cantilevers shelved including supports overhangs etc. also splays between floors and beams, etc., finishing the concrete surfaces rough, complete all as specified and directed. |
| 60 | Formwork to sides and soffits of suspended slab such as roof slab, floor slab, shelves and similar works n. exc. 200mm thick (Horizontal or sloping), finishing the concrete surfaces rough, complete all as specified and directed. |
| 61 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floors & roofs n exc 20cm wide & sides of RCC/PCC bands in walls, horizontal or sloping, & similar work exc 10cm but exc 20cm wide, rough finished surfaces of concrete, complete all as specified and directed |
| 62 | 40mm thick sand filling under floors in layers n exc 25mm thick including watering and consolidation, complete all as specified and directed. |
| 63 | PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork, complete all as specified and directed. |
| 64 | 100mm thick cement concrete type C-2 1:3:6 (40mm graded crushed stone aggregate) as in flooring, finished even and smooth without using extra cement, complete all as specified and directed. |
| 65 | 75mm thick cement concrete type C-2 1:3:6 (40mm graded crushed stone aggregate) as in sub floors, sub bases, floors and pavings etc complete all as specified and directed. |
| 66 | 100mm thick lean concrete type C-2 1:3:6 (40mm graded crushed stone aggregate) as in sub floors, sub bases, floors and pavings etc complete all as specified and directed. |
| 67 | PCC type C-1, 1:3:6 (using 20mm graded crushed stone aggregate) as in plinth protection 75mm thick laid in slope finished even and fair including making joints not more than 2.5 m (or as directed) and at corner, filled with bitumen 85/25 and sand in ratio 1:2 by weight complete all as specified and directed. |
| 68 | Non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.18 sqm in floors etc set and jointed (joint free) in neat cement slurry and pointed in coloured cement over 15mm thick screed bed or bedding layer of mortar in CM 1:4 and dismantling floor, hearth or walls tilling and terrazo topping including cement mortar bedding ( but not backing), rubish off the premises, complete all as specified and directed. |
| 69 | Glazed ceramic coloured tiles 300mm x 600mm x 7-8mm thick as in vertical surfaces such as skirting dado etc set and jointed in neat cement slurry, pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 to receive tiles and dismantling floor, hearth or walls tilling and terrazo topping including cement mortar bedding ( but not backing), rubish off the premises, complete all as specified and directed. |
| 70 | 20mm granite work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms etc. including cutting mouling, poishing and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed. |
| 71 | 60mm thick factory made machine pressed precast concrete, coloured interlocking paver block with cement and coloured pigment (topping thickness not less than 5mm thick with white cement and non-fadable epoxy coated colour pigment), any shape, size and design as approved by Engr-in charge confirming to IS 15658-2006, M-35 grade, complete all as specified and directed. |
| 72 | 18-20mm thick machine cut kota stone slab flooring over 20mm thick screed bed in cement mortar 1:6 base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and directed. |
| 73 | 18-20mm thick machine cut kota stone slab in riser of steps, skirting, dado and pillar laid over with 15mm thick screed bed in cement mortar 1:4 base and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and directed. |
| 74 | 15mm bore Steel water tubing, galvanised, \\"medium grade\\" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor including taking down existing steel water tubing, complete all as specified and directed. |
| 75 | 20mm bore Steel water tubing, galvanised, \\"medium grade\\" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor including taking down existing steel water tubing, complete all as specified and directed. |
| 76 | 15mm bore bib tap,chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule, fixed in repair, complete all as specified and directed. |
| 77 | 15mm bore stop valve/angel valve, chromium plated cast copper alloy, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or union (fixed in repairs), complete all as specified and directed. |
| 78 | 15mm bore concealed type stop valve/angel valve, chromium plated cast copper alloy with long shank and cup, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or union (fixed in repairs), complete all as specified and directed. |
| 79 | 15mm bore pillar tap, copper alloy with capstan head, chromium plated screwed down high pressure, with or without lettered hot/cold with long screwed shanks and fly nuts screwed for iron pipe, fixed in repair, complete all as specified and directed. |
| 80 | S&F in repair vitreous China ware Oval counter type wash hand basin of size 560 x 470 x 190 mm incl 32 mm dia CP waste coupling and PVC waste pipe fixing on granite slab complete all as specified and directed. |
| 81 | S&F in repair vitreous china squatting pan water closet, orissa pattern, size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe but including fixing of flush pipe) including cast iron 'P' or 'S' trap, front or back inlet and foot rests, any pattern including cement concrete bedding, complete all as specified and directed. |
| 82 | S & F in repairs vitreous china wash down water closet pan \\"Pedestal\\" coloured including fixing bolts etc including PVC seat & cover, white with flat bottom including MS, CP or aluminium anodised hinge devices & making good to floor in cement mortar M-15 (1:2:4) type B-1 (using 20mm graded crushed stone aggregated, complete all as specified and directed. |
| 83 | S & F in repair 10 litre capacity PVC valveless, low level, synphonic action type, flushing cistern, with inlet, ball valve, float valve, handle including brackets including 32mm dia PVC flush pipe of suitable size and making necessary connections, complete all as specified and directed. |
| 84 | PVC connection 15mm size with PTMT nuts at both ends of length 450mm for hot and cold water, fixed in repair, complete all as specified and directed. |
| 85 | Brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges with side hook fitting with 50mm long SS screws and PVC plug (fixed in repair), complete all as specified and as directed. |
| 86 | S&F in repair 125mm size brass chromium plated shower rose with or without swivel joints, any size including fixing to steel pipe of 15mm dia or union, complete all as specified and as directed. |
| 87 | 600 mm x 450 mm bevelled edge mirror of selected quality glass mounted on 6 mm thick AC building board or BWP commercial plywood and fixed to wooden plugs/PVC rawl plug with chromium plated brass screws and cup washers, complete all as specified and directed. |
| 88 | 110mm bore dia PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed. |
| 89 | 75mm bore dia PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed. |
| 90 | 110mm bore dia PVC (SWR) bends, complete all as specified and directed. |
| 91 | 75mm bore dia PVC (SWR) bends, complete all as specified and directed. |
| 92 | 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement, fixed in repairs, complete all as specified and directed. |
| 93 | 75mm bore pipe PVC (SWR) vent cowl and fixed, complete all as specified and directed. |
| 94 | Preparation of new plastered or unplastered surfaces of wall and applying three coats of white wash,complete all as specified and directed. |
| 95 | Preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white wash,complete all as specified and directed. |
| 96 | Preparation of new plastered or unplastered external surfaces of walls and chajjas and applying two coats of cement base paint over a coat of alkali-resistant priming paint, complete all as specified and directed. |
| 97 | Preparation of new plastered or unplastered external surfaces of wall and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm, complete all as specified and directed. |
| 98 | Preparation of new steel surface any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint, complete all as specified and directed. |
| 99 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and directed. |
| 100 | Point wiring using 3x1.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade (Phase, neutral and earth wire) with proper colour coding drawn through and incl PVC rigid concealed conduit medium grade (ISI Marked) of dia not less than 20mm and 1.5mm thick and connected to common earth dolly with 1.6mm thick MS/GI pressed steel sunken box of adequate size and 3mm thick plastic laminated sheet cover fixed with brass screws complete including cutting chases grooves for concealed wiring for light/fan/bell point controlled by one switch and making good (in CM 1:4) the surface as per existing complete all as specified and directed. |
| 101 | All as per Ser item No 100 here-in-before but for one 5/6 Amp socket outlet points on same board controlled by one switch. |
| 102 | All as per Ser item No 100 here-in-before but for one 5/6 Amp socket outlet points on independent board controlled by one switch. |
| 103 | All as per Srl item No 100 here-in-before but for one 15/16 Amp socket point with 3x2.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor. |
| 104 | Point wiring using 3x1.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade (Phase, neutral and earth wire) with proper colour coding drawn through and incl PVC rigid concealed conduit medium grade (ISI Marked) of dia not less than 20mm and 1.5mm thick and connected to common earth dolly with 1.6mm thick MS/GI pressed steel modular sunken box of adequate size and 3mm thick plastic laminated sheet cover fixed with brass screws complete including cutting chases grooves for concealed wiring for light/fan/bell point controlled by one switch and making good (in CM 1:4) the surface as per existing complete all as specified and directed. |
| 105 | All as per Ser item No 104 here-in-before but for one 5/6 Amp socket outlet points on same board controlled by one switch. |
| 106 | All as per Ser item No 104 here-in-before but for one 5/6 Amp socket outlet points on independent board controlled by one switch. |
| 107 | Modular one way switch 10 Amp, 1 module, complete all as specified and directed. |
| 108 | Modular socket outlet, 6A-2/3 pin combined 2 module, 230 volts complete all as specified and directed. |
| 109 | Switch piano flush button single pole one way 5/6 Amp 240 volts complete all as specified and as directed. |
| 110 | Switch piano flush button with shutters single pole one way 15/16 Amp 240 volts complete all as specified and as directed. |
| 111 | Socket outlet 2 in 1, 3 pin, 5/6 Amps, flush type, 240 volts complete all as specified and as directed. |
| 112 | Socket outlet 2 in 1, 6 pin, 6/16 Amp flush type, 240 volts complete all as specified and as directed. |
| 113 | Ceiling rose 3 terminal bakelite 65mm x50mm surface type, PVC/ Polycarbonate, isolated body, complete all as specified and directed. |
| 114 | 20 Watt 4 feet long batten luminaire with polycarbonate housing, high quality opal finish diffuser. The luminaire should have a CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 2000 nominal lumens and an System efficacy of at least 100 lumen/watt and maximum system wattage of 20 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 and THD <10% and suitable for an operating voltage range of 140-270V AC. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters, complete all as specified and directed. |
| 115 | 10 Watt 2 feet long batten luminaire with polycarbonate housing, high quality opal finish diffuser. The luminaire should have a CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 2000 nominal lumens and an System efficacy of at least 100 lumen/watt and maximum system wattage of 20 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 and THD <10% and suitable for an operating voltage range of 140-270V AC. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters, complete all as specified and directed. |
| 116 | 10W bulk head LED luminaire, surface mounted, with and integrated electronic driver with luminous efficiency ≥ 100 lumens/watt operating voltage 140V-240V, IP 65 protection complete with all accessories internally prewired and including connecting up with suitable size flexible copper conductor cable from ceiling rose to connector of LED fitting and making good disturbed surface of wall with cement mortar 1:4 and finishes to match exisiting surface, complete all as specified and directed. |
| 117 | Replacement of MCB DB, SPN, 8 way sheet metal enclosures double door 230 V AC, 50 Hz AC with IP 54 and IK 09 rating having fully insulated copper busbar of rating 200 Amps, insulated neutral bar, earth bar and cable ties for cable management including polyuthrene gasket complete complete in all respect flushed in wall including cutting chases on wall for taking out old unsv DB and fixing of new DB and making good disturbed surface of wall with cement mortar 1:4 and finishes to match exisiting surface, complete all as specified and directed. |
| 118 | MCB DB, SPN, 8 way sheet metal enclosures double door 230 V AC, 50 Hz AC with IP 54 and IK 09 rating having fully insulated copper busbar of rating 200 Amps, insulated neutral bar, earth bar and cable ties for cable management including polyuthrene gasket complete complete in all respect flushed in wall, complete all as specified and directed. |
| 119 | MCB, SPN, AC, 240 volts \\"B\\" series capacity of 40-63 Amps, 10kA and making connections, complete all as specified & directed. |
| 120 | MCB, SP, AC, 240 volts \\"B\\" series capacity of 6-32 Amps, 10kA and making connections, complete all as specified & directed. |
| 121 | 35 Watt LED wall security lights of having pressure die cast aluminium housing with system lumens efficiency≥100 lumen/W, IP65 protection, IK07 rating, inbuilt electronic driver with PF>0.95 incl GI bracket of suitable dia bend to shape and fixed to wall by means of clamps or nuts bolts and connecting up with three core twisted flexible copper conductor cable, complete all as specified and directed. |
| 122 | 25 Watt LED wall security lights of having pressure die cast aluminium housing with system lumens efficacy≥100 lumen/W, IP65 protection, IK07 rating, inbuilt electronic driver with PF>0.95 incl GI bracket of suitable dia bend to shape and fixed to wall by means of clamps or nuts bolts and connecting up with three core twisted flexible copper conductor cable including taking down old light & fittings, complete all as specified and directed. |
| 123 | Disconneting & taking down ceiling fan/ exhaust fan/ wall fan any type/capacity for servicing, strip opening of fan including servicing and greasing complete. Re-assembling and refixing to the same/other location after replacing rubber reel, fixing bolts and nuts with lock pins, connectors for complete fan as required, testing complete after servicing and fixing for smooth and noise free operation, complete all as specified and directed. |
| 124 | 1100 volt grade heavy duty XLPE cable with PVC insulated aluminium conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 16 sqmm nominal cross section 2.0 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers, complete all as specified and directed. Note- Earth work and protection work shall be measured and paid for separately under respective items of BOQ. |
| 125 | 1100 volt grade heavy duty XLPE cable with PVC insulated aluminium conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 10 sqmm nominal cross section 2.0 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers incl taking down old unsv cable, complete all as specified and directed. Note- Earth work and protection work shall be measured and paid for separately under respective items of BOQ. |
| 126 | Ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including connecting up with three core flexible copper conductor cable of suitable size, nut bolt and other fixing material, complete all as specified and directed. |
| 127 | Sand cushioning to under groudnd cables in layers of sand of 23cm thick (8cm before laying the cable and 15cm thick after laying cable) in trenches complete as specified and directed.Note: Only punned thickness of 18cm shall be measured and paid. |
| 128 | Bricks laid in trenches flat with width equal to length of brick for cable protection well burnt sub class 'B' laid across the cable complete all ad specified and directed. |
| 129 | 40mm dia GI tubing, light grade with all fitting laid in trenches or fixed on wall or along pole complete for protection of electric cable/strip, complete all as specified and directed. |
| 130 | Earthing complete in repair with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead GI wire 4mm dia by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvd iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of 2009.Note : RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy