| Sl. No. | Item Description |
| 1 | Sch 'A' Part-I B/R Part:-Taking down chowkats of frames with shutters (without taking off shutters from frames) area exceeding 1.50 Sqm but n exc 4 sq. m each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damages to jambs , walls for taking out hold fast shall be finished idetical to existing finish without any all as specified and directed by Engr- in - charge |
| 2 | Taking down chowkats of frames with shutters (without taking off shutters from frames) area not exceeding 1.50 Sqm each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damages to jambs , walls for taking out hold fast shall be finished idetical to existing finish without any extra cost of Govt) all as specified and directed by Engr- in - charge |
| 3 | S&F for Pressed steel door frame of size 165x60mm, double rebated for doors made out of 1.25mm thick mild steel sheet including necessary fixing lugs, hinges lock strike plate etc, including back filling of hollow portion of frame with cement concrete 1:3:6 type C-0 (using 12.5mm graded crushed stone aggregate) and fixing of hold fast complete all as specified and directed. |
| 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided for |
| 5 | M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 6 | S&F Factory made 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 7 | S&F 35 mm thick, 2nd class hard wood factory made, glazed & skeleton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc. Sizes of members of shutters as specified in SSR Part I, Section 8, Clause 8.24 (a) complete all as specified and directed. |
| 8 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples or using metal nut,bolts, fixed with wooden/MS beads & screws etc complete all as specified and directed. |
| 9 | M&L for preparation of newly steel and iron surface of any description width or girth exc 10 cm and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed complete all as specified and directed. |
| 10 | M&L for preparation of new wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified. |
| 11 | S&F factory made Solid PVC Door Frame of size 50mm x47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and directed. |
| 12 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 13 | S&F 200 mm long aluminium anodised barrel tower bolt of extruded section. |
| 14 | S&F 250 mm long aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of exturded sections or cast aluminium alloy all as specified and directed |
| 15 | S&F 150 mm long aluminium bow handles cast type anodised. |
| 16 | S&F 100 mm size S.S.butt hinges complete all as specified and as directed. |
| 17 | S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring. Fixed in floor Overall length of cover plate 140mm complete all as specified and directed. |
| 18 | S&F in repair 25mm outer dia stainless steel bright finished ,fancy type decorative drapery rod of thickness 20 gauge with ends caps in (pair) fixed to wall with screws ,PVC gully including all necessary fixing arrangement complete all as specified and directed. |
| 19 | S&F windows/ventilators (NCL ECO-4000 Series windows (double rebate windows or equivalent) fabricated from roll framed sections made of galvanised steel colour coated (Base steel as per IS 513 'D' quality galvanised as per IS 277 with zinc of 120gm/sqm) with total coated thickness of 0.58mm. Section of frame should be of 72mmx55xx, section for mullion should be of 72mmx50mm, section of shutter frame should be of 47mmx20mm, section for fixed glass bead should be of 12mmx12mm, and section for fly mesh should be of 40mmx20mm, section for frame glazed shutters and mesh shutters should be cut to length and miter jointed with polyproppylene corner brackets, mullion section should be joined with frame/mullion using mullion cap ethyl propylene diamien monomer (EPDM) gasket should be used all around glass in shutter and fixed glass. Spoon section should be used around fly mesh to fix mesh in mesh shutter including SS pivot hinges-1 set, Seccolor handle & Seccolor stay and 4mm plain float glass and stainless steel 32 gauge fly mesh of 25 holes per Sqcm and powder coated frill made of 10mm Square MS bars welded at 150mm c/c, 6mmx12mm MS flat and fixed to window frame with screws, with provn of suitable opening for AC/Desert cooler where required, including taking down old window/ventilators nay type and description, complete all as specified and as directed. |
| 20 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. |
| 21 | S&F 5.5 mm thick frosted/tinted/ordinary sheet glass figured, pin head type or-dinary quality and glazing with rubber neoprene packing for aluminium door/windows in square n exc 0.5 sq. m in each pane, complete all as specified and as directed. |
| 22 | S&F ACP sheet 4mm thick , for fixing in aluminium frame including necessary fittings and fixtures, complete all as specified and as directed. |
| 23 | M&L 18mm thick Pre-laminated Medium density fibre board, exterior grade, pre-laminated one side with decorative choice lamination & other side balancing white lamination with 3mm thick teak wood lipping fixed with screws to steel/timber frame work as in shutters & shelf of Kitchen cabinet, cupboard, partition & almirahs etc including taking down old shutters & shelf etc complete all as specified and directed. |
| 24 | M&L for 2nd class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed. |
| 25 | M&L for 2nd class hard wood Plain fillets, exc 6 & n exc. 13 Sq.cm, bull nosed, splayed, chamfered or rounded on one edge or face section, clean sawn, secured with nails or brads, complete all as specified and directed. |
| 26 | S&F hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws, Size of hasp and staple in mm 100 complete all as specified and directed by Engr-in-Charge. |
| 27 | S&F Continuous (piano) hinges 30mm Width of flaps (when open) ,mild steel, bright finish or electrogalvanised complete all as specified and directed by Engr-in-Charge. |
| 28 | S&F Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and directed. |
| 29 | Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing) removing serviceable tiles to store and rubbish off the premises and removing the debris outside from defence land complete all as specified and directed . |
| 30 | M&L for 16-18 mm thick granite (pure black) work (table rubbed and polished) in steps, jambs pillars, window cills ,cooking platform and like including pointing in white cement (1:2) using marble dust with admixture of pigments to match with shade or granite over including 20mm thick screed bed or bedding layer in cement mortar 1:4 etc complete all as specified and directed.Note:- The stone slab shall be in one piece over kitchen plateform,window cill and making gas pipe holes 25mm dia with rounded holes and all open edges to be half rounded complete all as specified and directed by Engr-in-Charge. |
| 31 | M&L for coloured Glazed ceramic tiles in vertical surface such as dado etc 450mmX 300mmX 7 to 8mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of the tiles over and including 10mm thick rough cement plaster to receive tiles in CM 1:4 complete all as specified and as directed. Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE and Rates also including in this item for necessary raking circular cutting or notching and waste on tiles. |
| 32 | S&F Vitrified Ceramic tiles 10 mm thick light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed by Engr-in-Charge.Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE and Rates also including in this item for necessary raking circular cutting or notching and waste on tiles. |
| 33 | S&F Vitrified Ceramic tiles 10 mm thick light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm in skirting, dados etc etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles over and including 10mm thick rough cement plaster to receive tiles in CM 1:3 complete all as specified and directed by Engr-in-Charge.Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE and Rates also including in this item for necessary raking circular cutting or notching and waste on tiles. |
| 34 | M&L for non-skid ceramic coloured tiles, area of each tile exceeding 0.18 square metre but not exceeding 0.38 square metre of 7 to 8 mm thick set and jointed in neat cement slurry and pointing in coloured cement to match shade as in skirting/dado including 10mm thick rendering in cement mortar 1:4 complete all as specified and as directed. |
| 35 | Taking down cement plaster of any description and thickness on walls/ceilings etc including racking out joints, hacking for key, scrubbing down with water etc including necessary scaffolding up to four storeys height of bldgs if required and removing of debris out of MoD land complete all as specified and as directed. |
| 36 | M&L for rendering 10 mm thick on other than fair face of brickwork or concrete wall surfaces in cement mortar 1:6 and finished even and smooth without using extra cement, including necessary scaffolding if required, complete all as specified and as directed. |
| 37 | M&L for rendering 15mm thick in CM 1:4 in two layers with backing coat 10mm thick and second coat of 5mm thick WPC (as per manufacturer’s instructions) on fair faces of brick work ,concrete surface of wall, fin, facia, chajjas, parapet and similar article finished surface even and smooth without using extra cement including necessary scaffolding if required, complete all as specified and as directed.(Note:- WPC shall be measured and paid separately) |
| 38 | Supply only `Liquid Water Proofing Compound complete all as specified and as directed . |
| 39 | M&L for rendering 5mm thick on fair faces of brickwork or concrete surfaces in cement mortar 1:3 as on ceiling complete all as specified and directed. |
| 40 | M&L for preparation of newly plastered external surfaces of wall and applying two or more coats of 100% Premium acrylic emulsion paint Apex Ultima (Weather coat) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm (weather proof/weather coat) over and including 1.5mm thick wall care putty without any brush marks on the surface in any colour over including necessary scaffolding up to three storeys height of bldgs,Shade/colour shall be approved by GE, complete all as specified and as directed. |
| 41 | M&L for preparation of newly plastered internally surfaces of wall and applying 1.5mm thick wall care putty on the surfaces & making the surface absolutely smooth surface and applying one coat of primer (as per manufacturer’s recommendations) on the surfaces and applying two coats of distemper oil emulsion, white or tinted, finished without any brush marks on the surface including necessary scaffolding up to four storeys height of bldgs if required, all painted areas site to be cleaned and hand over as earlier without any extra cost to Govt complete all as specified and as directed. Note:- Shade/colour shall be approved by GE. |
| 42 | M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash without any brush marks on the surface including necessary scaffolding if required complete all as specified and as directed. |
| 43 | M&L for complete removal of existing treatment internally surface of wall and applying min 1.5 mm thick wall care putty on the surfaces and making surface absolutely smooth and applying one coat of primer (as per manufacturer’s recommendations) on the surfaces and applying two coats of distemper oil emulsion without any brush marks on the surface in any tint including necessary scaffolding up to four storeys height of bldgs if required ,Shade/colour shall be approved by GE,complete all as specified and as directed. |
| 44 | M&L for complete removal of existing treatment externally surface of wall and applying Two or more coats of 100% Premium acrylic emulsion paint Apex Ultima (Weather coat) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm (weather proof/weather coat) over and including 1.5mm thick wall care putty without any brush marks on the surface in any colour over including necessary scaffolding up to three storeys height of bldgs,Shade/colour shall be approved by GE, complete all as specified and as directed. |
| 45 | M&L for preparing old plastered or unplastered wall surfaces including cornices,pillasters by brooming down with steel wire brushing scrapping down smoke soot,moulds moss and effloresent salts and treating oily and greasy spots etc and as directed and applying two finishing coat of white wash on ceiling, complete all as specified. |
| 46 | M&L for repairing to chajjas, roof projection and facias of exposed reinforcement surface or damaged loose RCC surface including cutting down rusted/exposed reinforcement and applying one coat of cement slurry and filling with cement concrete 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) and finished with cement mortar 1:3 using coarse sand. Thickness of RCC member not exc 150 mm including scaffolding up to 8.0m height complete all as specified and as directed .Note : No extra rates of scafffolding will be paid separately against this item. |
| 47 | M&L for 25mm thick PCC (1:2:4) type B-0 using 12.5mm graded crushed stone aggregate as in padding concrete (levelling course) on roof completed all as specified and directed. |
| 48 | M&L for liquid water proofing treatment to RCC roof slab incld dismantling of existing treatment of any description in following procedure : (a) Laying 10mm thick rendering in Cement mortar 1:4 mixed with WPC 3% by weight of cement on fair faces of concrete roof surfaces , finished even and fair to receive treatment on roof Complete (b) Applying first coat fiber reinforced elastometic liquid water proofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibers with sun reflective index (SRI) of 100-110, having minimum elongation of 350%, tensile strength 2.9 Mpa and shall have reack bridging ability upto 2.5mm and shall resist 10 bars of hydrostatic pressure reduce surface temperature upto 10 degree celsius with 3.3% dilution as priming coat (c) laying of fiber mesh 0.3mm thickness weave in leno pattern having weight 4.5 gm/ Sqm and pasting it properly with overlap of 50mm and allow it to dry (d) Applying second coat undiluted @ 0.45 ltr/ sqm as directed by Engr-in-Charge (e) Applying third and final coat undiluted @ 0.45 ltr/ sqm as directed by Engr-in-Charge. (The rate includes for filling cracks in existing roof with cement putty using suitable bonding agent (shalcrate 42) before laying cement plaster) |
| 49 | Demolition of brick work or stone/ boulder masonry built in cement mortar or cement lime mortar including all quions, wall, arches, pillars, man-holes, drain etc complete all as specified and directed. |
| 50 | M&L for Brick work using sub class 'B' bricks straight or curved on Plan exc 6m mean radius built in CM 1:6 all as specified and directed |
| 51 | M&L for Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 52 | M&L for precast reinforcement cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate, in cover slabs( for manholes etc.) chulla hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar (1:6) complete all as specified and directed. (Reinforcement shall be measured and paid separately). |
| 53 | M&L for Mild steel TMT bar 6 to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 54 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 55 | M&L for providing cement concrete 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in coping, bed blocks including necessary form work, weathering slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 56 | M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped end etc., complete all as specified and as dircted. |
| 57 | Demolition of cement concrete or lime concrete (unreinforced) in ground floors and Pavings not exc 15 cm thick (below or above ground level ) and removing the debris outside from defence land complete all as specified and directed . |
| 58 | Demolition of Lime concrete / Mud phuska / PCC of any description and in any position not otherwise specifically provided for renewal including removal of demolished material beyond the Md land to a distance exceeding 500mtr not exceeding 1.5KM completed all as specified and directed. |
| 59 | M&L for Cement concrete 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection and paving 75mm thick laid in slope finished even and fair including making joints at every 2.5 m and at corner filled with bitumen 85/25 and sand in ratio 1:2 by weight and complete all as specified. |
| 60 | M&L for 75 mm thick Cement concrete 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) as in,sub base, sub floor etc, complete all as specified and directed by Engr-in-Charge. Note:- Finishing surfaces of concrete to be even and rough to receive the topping layer or floor tiles etc. |
| 61 | M&L for non-abrasive paving (endura) tiles 300mm x 300mm x10mm thick (square/ rectangular) polished, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement over & including 15mm screed bed CM 1:4 to match complete all as specified and directed by Engr-in-Charge.Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE and Rates also including in this item for necessary raking circular cutting or notching and waste on tiles and Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.& Brushing neat cement slurry with 3.0kg of cement per sqm. |
| 62 | M&L for precast cement concrete paver block of thickness 60mm with matt finish of M-40 garde, laid in design (as approved and sample kept in GE office) by combination of two size of blocks 8 inch x 4 inch (grey) and 4 inch x 4 inch (coloured) as per the sample kept in GE office, including n exc. 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed by Engr-in-Charge. |
| 63 | S&F Rotational moulded polyethlene water storage tanks three layers of 500 ltrs capacity ISI marked (cylindrical vergical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm thick Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed including Dismantling of old brocken water tanks and refixing of inlet, outlet & over flow pipe etc complete all as specified and as directed. |
| 64 | S&F in repair Gun-metal, globe or gate valves 15mm bore, with iron wheel head, screwed both end for iron pipe complete all as specified and directed |
| 65 | Taking up or down 15mm bore, steel tubing and connection including cleaning for refixing or removal from site complete all as specified and directed. |
| 66 | S&F 15mm bore Steel water tubing 'medium grade', galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed. |
| 67 | Taking up or down 20mm bore, steel tubing and connection including cleaning for refixing or removal from site complete all as specified and directed. |
| 68 | S&F 20mm bore Steel water tubing 'medium grade', galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed. |
| 69 | Cutting chase, pining in making good to facings where required and pointing in cement mortar (1:3) to ends, cutting chases for concealed water tubing ror concealed conduit wiring etc and making good cutting not exc 10cm girth., complete all as specified and directed. |
| 70 | S&F in repair 15 mm bore long body CP Bib taps cast copper alloy fancy type with capstan heads (chromium plated),and cup screwed down, high pressure for iron pipe complete all as specified & directed. |
| 71 | S&F in repair 15mm bore brass chromium plated central hole basin mixer fancy type without popup waste system with 450mm long braided hoses, screwed down complete all as specified and as directed. |
| 72 | S&F in repair of fancy type 15mm bore brass chromium plated wall mixer with provn of overhead shower with 115mm long bend pipe on upper side, connecting legs & wall flanges for mixing hot and cold water, screwed down, high pressure, complete all as specified and as directed. |
| 73 | S&F in repair corner sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard & railing 60cm long fixed with chromium plated brass screws and wooden/plastic cleats complete all as specified and directed. |
| 74 | S&F in repair Tubular towel rail/ring, ISI marked 60cm long between flanges , 20mm dia 'D' type Brass Chromium plated incl brackets, fixed with chromium plated brass screws and wooden/plastic cleats complete all as specified and directed. |
| 75 | S&F in repair CP stop cock/angle valve cast copper alloy screwed down high pressure ,with crutch or butterfly handle screwed both ends for iron pipe or for union of 15 mm bore complete all as specified & directed. |
| 76 | S&F in repair 15mm dia 600 mm long PVC connection including brass check nut at both ends screwed both end for iron pipes complete all as specified and directed |
| 77 | S&F in repair overhead shower 125 x 125 mm with 200mm long shower arm and wall flange including fixing to steel pipe or union, complete all as specified and as directed. |
| 78 | S&F in repair fancy type stainless steel soap dish, any type fixed to plugs chromium plated brass screws complete. Make: Cera or equivalent in any of the make mentioned in list of product. |
| 79 | S&F in repairs PVC Coloured bathroom cabinet looking mirror divided into shelf overall size 622mm x 432mm complete all as specified and as directed by Engr-in-Charge. |
| 80 | S&F in repair fancy type brass chromium plated health faucet ABS body with wall hook and 1m long chrome plated PVC hose pipe, complete all as specified and as directed. |
| 81 | S&F in repair fancy type brass chromium plated toilet roll holder with flap guard complete all as specified and as directed. |
| 82 | S&F in repair single Piece-WC with UF soft close seat cover, Hinges, Fixing Accessories, Accessories Set and Cistern fittings Size: 680 x360 x720 mm, S Trap-220mm white with combined flush tank (Cascade type) incl seat covers complete all as specified and as directed. |
| 83 | S&F in repair vitreous china under counter wash basin with fixing accessories, oval shape snow white of size 560 x 400 x 205 mm, incl 32mm dia brass chromium plated waste coupling, complete all as specified and as directed. |
| 84 | Taking down eaves gutters or SWR pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and as directed. |
| 85 | S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls all as specified and directed. |
| 86 | S&F PVC (SWR) bends any radius 110mm dia all as specified and directed. |
| 87 | Demolition and breaking up drain pipes (Salt glazed ware, PVC/AC or Reinforced concrete) set in cement mortar,and taking out of trenches, if required, Internal dia of pipe in 75mm/100mm complete all as specified and directed |
| 88 | S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors all as specified and directed. |
| 89 | S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors all as specified and directed. |
| 90 | S&F PVC (SWR) bends any radius 75mm dia all as specified and directed. |
| 91 | S&F in repairs 75mm PVC floor trap, ISI marked with CP grating with/without waste pipe hole incl jointing to waste pipe fixed with solvent cement complete all as specified and as directed. |
| 92 | S&F in repairs of PVC (SWR) 75mm bore 'T' equal or unequal complete all as specified and directed. |
| 93 | S&F in repairs of PVC (SWR) 110mm bore vent cowl complete all as specified and directed. |
| 94 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed. |
| 95 | M&L for Cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) in foundations, filling and mass-concrete, complete all as specified and as directed. |
| 96 | M&L for Removing excavated Soils material exc. 1.5 km but n exc. 5 km and depositing where directed complete all as specified and directed. |
| 97 | M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm with any type of soil complete all as specified and directed. |
| 98 | M&L for reinforced concrete pipes, class NP-3, 150 mm dia laid in trenches and jointed complete with collars, complete all as specified and as directed. |
| 99 | M&L for Concrete bed to drain pipes including packing under,and haunching against the sides of pipes after they are laid and tested in Cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate for Bore of pipe 150 mm dia complete all as specified and directed |
| 100 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets |
| 101 | S&F false ceiling with fibre cement designer tiles ivory painted (high pressure steam cured) of 4 mm thickness (as per IS:14862) of size 595x595 mm and any one of the design (oceanic, lake & hill, cascade or electra) in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms, both side inclusive) consisting of main 'T' runnerwith suitably spaced joints to get required length, and 15x32mm made if 0.30 mm sheet and cross 'T' at 600 mm c/c to form a grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main 'T' runners to be suspended from ceiling using GI soffit cleats fixed to existing ragter, purlin, etc with galvanised butterfly level slips, spaced at 1200 mm c/c along main T, bottom exposed width of 15 mm of all T-sections shall be centra black pre-painted with polyester paint, and having a load bearing capacity of 12 KG/spm, and refixed all existing electric wiring and fixture all complete at all heights as per direction of Engineer-in-Charge. |
| 102 | M&L for preparation of old decorated surfaces of walls and cornices, spoiled by smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots by scraping and applying one coat of oil emulsion distemper, complete all as specified and directed by Engr-in-Charge. |
| 103 | Excavation in post holes (or similar holes) each n exc 0.5 cum getting out, returning, filling in and ramming earth and removing surplus soil to a distance n.exc 50 m in any type of soil all as specified & directed. |
| 104 | M&L for treating surfaces of ends of posts, backs , etc., area n exc 0.1 sq. m each, with tar or coal tar black paint |
| 105 | M&L for PCC 1:2:4 , type B-1, using 20mm graded crushed stone aggregate as in post/strut foundation, filling and mass concrete complete all as specified and directed. |
| 106 | M&L for preparation of newly steel and iron surface of any description width or girth exc 10 cm and applying two coats of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and directed. |
| 107 | Dismantling timber scantling 40 Sq cm and over in section, in any position framed work complete all as specified and directed |
| 108 | Dismantling of Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings or PVC sheet in roof including ridges, sunshades or any position etc complete all as specified and directed. |
| 109 | S&F Steel work in tubular trusses/rectangular or square, hollow mild steel sections for structual use, including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed. |
| 110 | S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without anyattachment confirming with Fe 410-W(Gde-E- 250)quality-A complete all as specified and directed. |
| 111 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed by engineer in charge. |
| 112 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) or directed by Engr-in-Charge fixed with self tapping screws as specified |
| 113 | Sch 'A' Part-I E/M Part:-Taking down carefully copper or aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, sockets bulk, head fitting, tube light fitting by unscrewing carefully from boards etc and making good, distrubed surface of walls floors etc. |
| 114 | M&L for modular point wiring for one light/one fan controlled by one switch with 1.5 Sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable with and including PVC rigid concealed conduit heavy duty suitable size with all accessories including modular matallic flush box of suitable way with modular cover plate for modular switches and sockets , including green 1.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS cable as earth continuity conductor connected to comman earth dolly, including cutting chiseling for concealed piping and making good disturbed surface to match with the existing surface complete all as specified and directed. |
| 115 | All as per Srl item No. 114 here-in-before but modular call bell point complete all as specified and directed. |
| 116 | All as per Srl item No. 114 here-in-before but modular 3 pin 5 Amps socket outlet on the same board with other switch complete all as specified and directed. |
| 117 | All as per Srl item No. 114 here-in-before but modular 3 pin 5 Amps socket outlet on the independent board with other switch complete all as specified and directed. |
| 118 | All as per Srl item No. 114 here-in-before but modular 15/16 Amps socket outlet on the independent board with 2.5 Sqmm copper conductor FRLS cable and 2.5 Sqmm PVC insulated unsheathed copper conductor cable FRLS (green colour) as earth lead complete all as specified and directed. |
| 119 | M&L for modular point wiring with 4 Sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable with and including PVC rigid concealed conduit heavy duty suitable size with all accessories including modular matallic flush box of suitable way with modular cover plate for modular switches and sockets , including green 4 sqmm PVC insulated unsheathed multistrand copper conductor FRLS cable as earth continuity conductor connected to comman earth dolly, including cutting chiseling for concealed piping and making good disturbed surface to match with the existing surface complete all as specified and directed. |
| 120 | S&F ceiling rose 65 x 50mm three terminals complete all as specified and directed. |
| 121 | S&F Modular switch 1 way 6 A, 1 module complete all as specified and directed. |
| 122 | S&F Modular switch 1 way 16A, 1 module complete all as specified and directed. |
| 123 | S&F Modular Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed. |
| 124 | S&F Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed. |
| 125 | S&F Modular Fan regulator 6A 1 module , complete all as specified and directed. |
| 126 | S&F Modular Bell push6 amp one module complete all as specified and directed by Engr-in-charge.. |
| 127 | S&F of Bell , AC 230 Volts single Phase complete all as specified and directed by Engr-in-charge. |
| 128 | S&F in replacement sleek LED mirror light fitting 2 feet long 1x10 W including inbuilt ind driver complete with all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of suitable size complete all as required at site or directed. |
| 129 | Supply and installation of the electric water storage heater of ABS body type, 25 ltr capacity with rated power 2KW, 5 star rated, vertical type, thermally insulated mild steel tank with glass line coating inside the tank alongwith glass lined incoloy heating element with anti corrosive magnesium anode, NRV, thermostat, indicators and temperature adjustable knob including steel braided flexible connection for pipe of size 15mm bore with GI hexagonal adopters/nuts on both sides for inlet (cold water supply) & outlet (hot water supply) and including provision of wall mounting arrangements and mounting on wall with suitable size of anchor bolts with complete connection of water including testing after installation complete all as specified and as directed. |
| 130 | S&F in replacement energy saving decorative LED box type 20 W, 6500K, cool white , Lumen efficiency 110 lumen/watt, light fitting PVC housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver complete with all accessories prewired and making connections with twisted flexible copper cable of suitable size from ceilling rose/PVC connector to light fittings complete all as spd and directed by Engr -in -charge. |
| 131 | S&F in replacement decorative Wall mounted LED light in brass finish fixture with cognace hammered glass diffuser suitable for 12W LED lamp B22 base complete including 9 W LED Warm white lamp, connecting up with suitable size flexible copper cable complete all as specified and directed by Engr-in charge. |
| 132 | S&F in repair energy saving surface mounted, Bed Side Lamp luminaire 3 W polycarbonate diffuser with IP 66 protection connecting up with suitable size flexible copper cable complete all as specified and directed by Engr-in charge. |
| 133 | S&F in replacement of 20W LED Post top 360 degree light with aluminium enclosure, IP 65 energy saving, environment friendly, powered with high power LEDs for light source and die casted heat sink exhibits classic Victorian look with symmetrical light distribution having clear cover for bright illumination including connection with copper wire complete all as specified and directed. |
| 134 | M&L for providing/ cutting the round/ square hole of required size in wall finishing the distrubed surfaces as per existing finishes complete all as spd and supply and fixing propeller PVC type AC ventilating fans, Single phase, 230 volts 250 mm sweep complete and supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated copper cable suitable from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed by Engr-in-charge. |
| 135 | S&F & testing ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and connecting with flexible copper conductor of suitable size, 3 core and including writing of MES No with black paint complete all as specified and as directed. |
| 136 | S&F in replacement of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 12 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases in wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. |
| 137 | S&F in replacement of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases in wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed. |
| 138 | S&F in replacement for MCB SP 240 volts any rating from 6 to 40 amps, 'C' cruve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed. |
| 139 | S&F in replacement for MCB SPN 240 volts any rating from 6 to 40 amps, 'C' cruve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed. |
| 140 | S&F in replacement for MCB SPN 240 volts any rating from 63 amps, 'C' cruve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed. |
| 141 | S&F in replacement of existing unsv sheet metal enclosure with sheet metal enclosure MCB distribution board single pole and neutral with a two pin and earth plug and socket 20 amps 240 volts, complete with one single pole MCB of 20 amps 'C' curve complete all as specified and directed . |
| 142 | S&F in replacement sub Main Wiring with two PVC insulated unsheathed multistrand FRLS-H flexible copper conductor cable of size 2x6 sqmm and one PVC insulated multistrand unsheathed FRLS flexible copper conductor cable of size 6 sqmm (green colour) as earthing lead connecting to main earthing dolly drawn in and including non metallic PVC concealed conduit 20mm dia complete and making good to disturbed surface complete of wall/floor with cement mortar and finishes to match the existing surface complete all as specified and directed. |
| 143 | S&F in replacement sub Main Wiring with two PVC insulated unsheathed multistrand FRLS-H flexible copper conductor cable of size 2x4 sqmm and one PVC insulated multistrand unsheathed FRLS flexible copper conductor cable of size 4 sqmm (green colour) as earthing lead connecting to main earthing dolly drawn in and including non metallic PVC concealed conduit 20mm dia complete and making good to disturbed surface complete of wall/floor with cement mortar and finishes to match the existing surface complete all as specified and directed. |
| 144 | S&F in replacement of old unsv sheet metal enclosures distribution boards, double door three phase 415 volts 4 ways vertical TPN DB for comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following (a) MCCB FOUR POLE 100 AMPS AC 415 VOLTS 25 KA=01 NO as incoming . ( (i) MCCB, MCB and DB should be of same make. (ii) The DB shall be flush fixed ,and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost.(iii)connection of theMCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped.(iv) all the vacant holes of the DB shall be provided with blank plates of appropriate size. (v) double continuous earth wire shall be provided for each three phase DB from earthing mains dolly. |
| 145 | S&F in replacement bldg secuirty light fitting energy saving high efficiency LED street light fitting 35 Watts, 5700 K, IP 66, having pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, prismatic polycarbonate cover complete including GI bracket of size 25 mm dia bent to shape having length on less than 0.9 mtr fixing with clamp etc and making connections using suitable size copper cable from ceilling rose/ PVC connector to light fittings or as directed by Engr-in-chrage. |
| 146 | M&L for earthing complete with galvanised steel earth plate electrode , 600 x600 x 6mm thick burried directly in the ground (earth pit not less than 2.25 mtr deep below ground level)with top edge of the plate not less than 1.5mtr below ground level connected to galvanised iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point , GI tubing 15 mm bore light grade protection pipe , GI watering pipe 20mm bore light grade with funnel and wire mesh , charcoal ,salt packed around the earth plate and precast PCC 1:2:4 (Nominal mix ) reinforced with XPM having weight not less than 4 kg /sqm including suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover including earth work in any type of soil , removal of surplus soil to a distance n.exc 50m and connecting , testing on completion complete all as shown on electric plate No 03 of SSR -2009 Part I complete all as specified and directed.(Note: Excavation and earth work is deemed to be included in the rates quoted). |
| 147 | S & F LED luminaire 600 mm X 600 mm , 35/36 watt 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver holder & driver & LED lamp suitable for roof ceiling including connecting up with driver flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-Charge. |
| 148 | Taking down single phase/three phase electric meter by disconnecting the electric connection and removing from meter box by descrewing the nut, bolt etc complete all as specified and directed by Engineer-in-chargeNote:-Meter will be deposited in store yard |
| 149 | Fixing of single phase/three phase electric energy meter and connecting up ncluding provision of PVC insulated and overall sheathed flexible copper conductor cable 3 core, 4Sqmm from main connection to DB complete all as specified and directed by Engineer-in-charge |
| 150 | Supply, laying and testing in replacement LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 16 sq. mm 2 core complete all as specified |
| 151 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil for laying of cable ,pole foundation,stay,laying of pipe etc complete all as specified and directed. |
| 152 | Returning filling in, including spreading ,leveling ,watering and well ramming in layers not exc 25 cm complete all as specified. |
| 153 | Removing excavated soil to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 154 | M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified (Note:-Punned thickness shall be measured and paid) |
| 155 | M&L for brick covering equal to length of bricks as mechanical protection to cable with well burnet sub class ‘B’ bricks laid as directed by the Engr-in-Charge. |
| 156 | S&F GI tubing light grade 50 mm bore for cable protection laid in trenches in road crossing or fixed to wall/Pole including fittings /clamp complete all as specified and directed. |
| 157 | Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 26,769.00 and any other reduction if any from quoted amount. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail