| 1 | Demolition of cement concrete(unreinforced ) in ground floors and pavings not exceeding 15cm thickness(below ;or above ground level) all as specified and directed. |
| 2 | M&L for 75mm thick PCC type D-2 (1:4:8) using 20mm graded aggregate as in sub base etc complete all as specified and directed |
| 3 | M&L For 25 mm thick, type B-1, 1:2:4 (20mm graded aggregate) as in sub base etc complete all as specified and as directed. |
| 4 | M&L Non skid vitrified Ceramic tiles 7 to 8 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.18sqm but not exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and joint free etc complete as directed. |
| 5 | M&L for screed bed or bedding layer of mortar 15 mm thick for laying floor/ wall finishes in CM 1:6. |
| 6 | M& L for rendering 10mm thick cement mortar in 1:4 as in backing coat complete all as specified and directed |
| 7 | M&L for glazed ceramic coloured tiles in vertical surface 350mmx450mmx7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed, |
| 8 | Dismantling stone slab and tiles of any description and thickness as in floor including cement mortar bedding and rubbish off the premises complete all as specified and directed. |
| 9 | S & F powder coated Aluminium sliding windows three track with two glass shutters using 4 mm thick glass tinted Modi guard and one shutter with stainless steel wire gauge wire cloth 0.31mm nominal dia of wire and width of aperture 1.61mm, using Aluminium powder coated sect, Alumini cleat, PVC track, bearing, handle lock rubber beading, etc complete including taking down existing steel/Aluminum windowNote Size of aluminium sections are as under :-(i) Three track top & vertical – Jindal main – 2010 Section No 20621.(ii) Three track bottom - Jindal main – 2010 Section No 20620.(iii) Shutter vertical section - Jindal main – 2010 Section No 20606.(iv) Shutter top & bottom - Jindal main – 2010 Section No 20604(v) Shutter vertical middle (interlock) - Jindal main – 2010 Section No 20605. |
| 10 | S&F 1.25mm thick steel rolling shutters, without ball bearing as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in positionas indicated complete push pull or manual type including locking arrangement(Safety lever locks mild steel with 4 levers for rolling shutters) , two coats of synthetic enamelled paint over a coat of red oxide including taking down old rolling shutter of any description and size complete all as specified and directed. |
| 11 | Demolition of solid blockmasonry , built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed. |
| 12 | M&L precast solid block masonry of block 1:3:6 type C-1 wall exceeding 10 cm in width and built in cement mortar 1:6 complete all as specified and directed. |
| 13 | M & L for complete scraping down of old decorative surface of walls with steel wire brushes of smoke spots, moulds, moss efflorecent salts and applying complete wall with 3mm POP/Birla putty and making smooth surfaces and applying two coats of Oil bound distemper over a coat of alkali resistant primer all as specified and directed by Engineer-in-Charge. |
| 14 | M & L for preparation of plastered or unplastered old decorated surfaces of walls including brooming down or scraping down with steel wire brushes of smoke spots, moulds, moss effloerent salts and treading oil and greasy spots and applyuing two coat of white (lime) wash complete all as spec ified and directed by Engineer-in-Charge |
| 15 | All as specified in Item No 14 above but applying two coat of white wash on ceiling. |
| 16 | All as specified in item No 14 above but applying one coat of Oil Bound distemper on walls complete |
| 17 | M & L for applying two or more coats of 100% premium acrylic emulsion paint having voc less than 50 gm/litre and UV resistance as per IS 15489 : 2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm over new surfaces |
| 18 | Taking down cement plaster on brick or stone walls or concrete surface etc including raking out joints, hacking for key scrubbing down with water all as specified and directed. |
| 19 | M&L 15mm thick cement plastering on stone masonry surfaces in CM (1:6) finishing surfaces even and fair without using extra cement incl preperation of new surface and applying two coats of Oil bound distemper over a coat of alkali resistant primer all as specified and directed by Engineer-in-Charge |
| 20 | Demolition of cement concrete (un-reinforced) in roof/floors other than ground level beam, stair case, landing, chajjas and similar items including water proofing treatment in any layers and removal of debris to distance exceeding 250m and not exceeding 500m from the site complete all as specified and directed. |
| 21 | M&L for 25 mm thick , PCC 1:2:4 (Type B1 using 12.5 mm gdd agg) as in levelling course to match the undulations of roof and in in coping , roof kerbs, fins including benching etc complete all as specified and directed |
| 22 | M&L for roof treatment consists of following steps incld taking down existing membrane complete all as specified and directed:(a) 10mm thick cement plaster 1:3 with integral WPC @3% weight of cement (not measured seperately) to be laid over the RCC roof slab when the concrete is green.(b) Applying a uniform coat of primer at 0.70 kg/sqm over cement plaster.(c) 3mm thick and weighing not less than 3.6kg/sqm Atactic Polypropylene Polymer(APP) modified bitumen-based prefabricated five layer water proofing membrane reinforcement with non woven polyster matt black finished over compatible primer with non woven polyster matt black finished over compatible primer at 0.40ltr/sqm of density at 25 degree centigrade 0.87-0.89 kg/litre and viscosity 70-160 cps or cold sticker and torch application of membrane with 10 cm overlap both ways after necessary preparation of surface complete as per manufacturers instructions.(d) Apply two coats of bitumastic-alumunium paint over the membrane. |
| 23 | M & L machine pressed precast concrete interlocking paver block with grey cement and no pigment, any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade with glossy finish, colour shade as decided by Engineer-in-Charge, |
| 24 | M&L sand filling under floors or in foundation including watering as required. Please Enable Macros to View BoQ information |