| Sl. No. | Item Description |
| 1 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm DSR 15.23.1 |
| 2 | Dismantling tile work in wall laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 12 mm to 20 mm M.R. |
| 3 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. DSR 15.25 |
| 4 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (including equivalent design mix DSR 15.2.1 |
| 5 | Demolishing R.C.C./R.B.C work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. DSR 15.3 |
| 6 | Careful removal of existing deteriorated/ damaged/ weathered lime plaster without damaging the surface below it. A.R. |
| 7 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge In cement mortar DSR 15.7.4 |
| 8 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres and below DSR 15.12.1 |
| 9 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area beyond 3 sq. metres DSR 15.12.2 |
| 10 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. DSR 15.18 |
| 11 | Removing white or color wash by scrapping and sand papering without causing damage to the below stone/brick/plastered surface.and preparing the surface smooth including necessary repairs to scratches etc. complete. A.R. |
| 12 | Removal of all old plumbing Internal & External Pipe including wc, washbasin, taps etc. from toilet & stacking servicealble materials within 50 M lead. A.R. |
| 13 | Removal of all Electrical Work (internal & external) including Switches & Wire and cables stacking servicealble materials within 50 M lead. A.R. |
| 14 | Removal of stains, dirt, blackening and other contaminants from Stone by using the solution of Non Ionic soap diluted with water . The soap solution should be mild and the recommeded PH Value is 7. A.R. INTACH 2.3 |
| 15 | Cleaning of enamel/modern/synthetic paint with help of suitable chemical A.R. INTACH 2.9.2 |
| 16 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. DSR 15.57 |
| 17 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: G.S. Sheet DSR 15.28.1 |
| 18 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. Distance upto 25 km DSR 1.1.1 |
| 19 | Providing and laying lime concrete in footings and bases excluding cost of centring and shuttering With graded stone aggregate 40mm nominal size and mortar comprising of 1 lime putty :1 surkhi : 1 coarse sand A.R. 4.1.2 |
| 20 | Providing and fixing Grouting Material with Lime mortar 1:2 (1 Lime : 2 Coarse sand) cost of required centering complete. AR |
| 21 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. (DSR 2.6.1) |
| 22 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) (DSR 4.1.8) |
| 23 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) DSR 6.1.2 |
| 24 | Brick work with bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) DSR 6.4.2 |
| 25 | Brick work in gauged arches in superstructure above plinth level and upto floor five level in cement mortar 1:3 (1 cement : 3 coarse sand) including centering and shuttering complete, for span up to 6 meters with common burnt clay F.P.S. (non modular) bricks of class designation 150 DSR 6.10 |
| 26 | Jack arch roof in Brick Work 1:3 (1 cement :3 Coarse sand ) centering & shuttering including all necessary T&P all complete in direction of engineer in charge A.R. |
| 27 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand) DSR 6.12.1 |
| 28 | Traditional brick masonry in Modular traditional bricks in lime mortar in proportion similar to the existing traditional lime mortar 1:1:1 (lime :1 surkhi: 1 finesand) A.R. |
| 29 | Traditional Brick work in plain arches in lime mortar 1:1:1 (1 lime : 1 coarse sand: 1surkhi) A.R. |
| 30 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mixor bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum DSR 5.33.2 |
| 31 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mixor bear the cost of extra cement All works upto plinth level concrete of m25 grade with minimum cement content of 330 kg /cum DSR 5.33A.1.1 |
| 32 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more DSR 5.22.6 |
| 33 | Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for massconcrete DSR 5.9.1 |
| 34 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and accessplatform DSR 5.9.3 |
| 35 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers andcantilevers DSR 5.9.5 |
| 36 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts DSR 5.9.6 |
| 37 | Preparation the surface and application:- a Through cleaning of the grease residuces dishuttering agent, dust, loose materials etc from the surface. b Loose particle should be cleaned from existing cavities in the concrete. c Existing construction joint should be opened in a “V” shape towards the inside, along their entire length, at a depth of 5 mm andProviding & lying waterproofing treatment on Roof by by way of lime mortar for restoration and waterproofing work:- a) Undulation/pit on the surface will be repaired by Doncrete LM.(Lime based mortar) b) After surface preparation, apply two coats primer Doncrete-MB (Methyl based bonding agent) mixing with Doncrete Lm mixing ratio 1Kg Doncrete MB: 1Kg Doncrete LM @300-400 gm per m² per coat. M.R. |
| 38 | Providing & laying Doncrete LM (Lime Mortar for restoration and building work) conforming to BS:EN:459-1,2, @25 mm thick. Mechanical characteristics :- Compressive strength 2,0 MPa (minimum) 7 days 5,1 MPa (medium)Compressive strength 5 MPa (minimum) 28 days 8,1 (medium) Compressive strength 10 MPa (minimum) 90 days 11,5 MPa (medium)Compressive strength 12 MPa (minimum) 180 days 13,2 MPa (medium) Copilliary Water Absorption (m²) < 1.0 Expansion 0,83 kg/dm³ (Make Doncrete/ Dr. Fixit/ Sikka) M.R. |
| 39 | 30‐40mm lime plaster in two coats with 20mm base coat in lime mortar 1:1:1 (1 lime : 1 Surkhi :1 Coarse Sand) and top coat in lime mortar 1:1:1 (1 lime : 1 Surkhi :1 Fine Sand) A.R. 9.5 |
| 40 | Lime concrete terracing on roofs with 25mm nominal size brick aggregate and 50% lime mortar 1:2 (1 Slaked lime : 2 surkhi) rammed and finished with gur and belgiri treatment complete including rounding of junctions with parpaet wall complete A.R. 4.6 |
| 41 | Providing and fixing chicken wire mesh (6mm x 6mm) of 24 gauge 200 mm wide along the joints of R.C.C. work and brick work with hooks/nails etc. complete so as to receiving the plastering work over chicken mesh as per the direction of Engineer‐in‐charge. A.R. 11.2 |
| 42 | Lime plaster 1:1:1 (1 slaked lime :1 surkhi: 1 fine sand) 20mmThick Double Coat A.R. 9.2.1 |
| 43 | Raking out the joints of brick masonary, scooping out dead and decayed mortar very slowly and carfully with scooping rods, then washing complete with hand spray pump. Preparing the surface for replastering including disposal of rubbish with 250m lead A.R. 12.3 |
| 44 | 40 mm thick rubbed stone flooring over 20 mm (average) thick base of lime mortar 1:3 (1 lime :3 coarse sand) with joints 3 mm thick, side buttered with lime mortar 1:2 (1 lime : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar Chunar Sand stone A.R. 7.8.1 |
| 45 | 50 mm thick rubbed stone flooring over 20 mm (average) thick base of lime mortar 1:3 (1 lime :3 coarse sand) with joints 3 mm thick, side buttered with lime mortar 1:2 (1 lime : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar Chunar Sand stone A.R. |
| 46 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying oftiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of Size of Tile 600 x 600 mm DSR 11.41.A.3.1 |
| 47 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of Size of Tile 600 x1200 mm DSR 11.41.A.3.2 |
| 48 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado andpillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. DSR 11.27 |
| 49 | Supplying, drilling/cleaning hole and fixing appropriate length of ETA Approved HILTI HRD C 10 / RAWLPLUG anchor suitable for fastenings both on concrete & masonary/aerated blocks. Length of anchor should be decided on the basis of embedment depth in base material, total frame thickness & gap between frame and base material. Anchor comprises of 10 mm diameter Polyamide PA 6 grade sleeve and of 7 mm diameter double threaded 6.8 grade countersunk head double threaded screw made of carbon steel galvanized to minimum 5 microns. CF 125 insulation foams should be used to fill the gaps between frame & base material. Fixing methodology to be followed as per manufacturers guidelines M.R.Frame anchor HRD-C 10x140 (a) |
| 50 | Supplying, drilling/cleaning hole and fixing appropriate length of ETA Approved HILTI HRD C 10 / RAWLPLUG anchor suitable for fastenings both on concrete & masonary/aerated blocks. Length of anchor should be decided on the basis of embedment depth in base material, total frame thickness & gap between frame and base material. Anchor comprises of 10 mm diameter Polyamide PA 6 grade sleeve and of 7 mm diameter double threaded 6.8 grade countersunk head double threaded screw made of carbon steel galvanized to minimum 5 microns. CF 125 insulation foams should be used to fill the gaps between frame & base material. Fixing methodology to be followed as per manufacturers guidelines M.R.Frame anchor HRD-C 10x100 (b) |
| 51 | Supplying, drilling/cleaning hole and fixing appropriate length of ETA Approved HILTI HRD C 10 / RAWLPLUG anchor suitable for fastenings both on concrete & masonary/aerated blocks. Length of anchor should be decided on the basis of embedment depth in base material, total frame thickness & gap between frame and base material. Anchor comprises of 10 mm diameter Polyamide PA 6 grade sleeve and of 7 mm diameter double threaded 6.8 grade countersunk head double threaded screw made of carbon steel galvanized to minimum 5 microns. CF 125 insulation foams should be used to fill the gaps between frame & base material. Fixing methodology to be followed as per manufacturers guidelines M.R.Frame anchor HRD-C 10x100 (c) |
| 52 | Lime punning with lime putty mixed with Gur,Bilgri,Urd and other ingredients followed by grinding to fine paste for smooth finish A.R. |
| 53 | Ornamental plaster works to match with the existing design using lime plaster (1lime putty:1surkhi) AR |
| 54 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) DSR 13.4.2 |
| 55 | Providing and mixing water proofing material (chemical) of approved superior quality in Lime concrete work in the proportion recommended by the manufacturers- PWD 599 |
| 56 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emul sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1%concentration DSR 2.35.3.1 |
| 57 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 meter height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 meter centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose.(2) The payment will be made once only for execution of all items for such works. DSR 24.2 |
| 58 | Manually removal of vegetation (major trees, climbing plants, creepers) from walls, columns, arches, floor etc in a skilled and careful manner, using appropriate tools and means and without causing any damage to the adjoining parts, including carrying and stacking the dismantled materials including lift/lower upto 11mtrs and lead upto 50 mtrs as directed by the engineer or architect in charge. The exposed surfaces will be coated with a paste made from ammonium sulphamate crystals or with \\"Tree killer\\"/ Weedicide/ Herbicide available in market. In this condition the root system may be left to absorb and die. Large sections of dead wood must not be left within the core. As they decay they will remove support and create voids and weaknesses in the wall. But pull off a well ‐ established mat of vegetation must be resisted. Tamping, grouting, pointing and resetting of brick / stones especially on wall top, must all be anticipated as remedial work. A.R. |
| 59 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood DSR 9.1.1 |
| 60 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Second class teak wood 35 mm thick shutters DSR 9.5.1.1 |
| 61 | Providing & fixing of 40 mm thick second class teak wood planks frame with louvers and 5.5mm thick glass fixed in frame help of beading, making as per original design all necessary T&P all complete in direction of engineer in charge. M.R. |
| 62 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. DSR 9.48.2 |
| 63 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. DSR 9.82 |
| 64 | Providing and fixing bright finished brass door latch with necessary screws etc. complete : 250x16x5 mm DSR 9.75.2 |
| 65 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete(a) 250 mm x 10mm 9.74.1 |
| 66 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete(a) 200 mm x 10mm 9.74.2 |
| 67 | Providing and fixing bright finished brass handles with screws etc. complete:125 mm DSR 9.81.1 |
| 68 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. DSR 9.83 |
| 69 | Providing and fixing of cast iron Railing With Wooden top rail design as per existing character including fixing in wooden member etc all complete in direction of engineer in charge. AR |
| 70 | Nano technology based protection technology coating lime wash paint coating lime wash paint Sand Stone Surface/ exposed brick work surface / wooden surface with nano technology based paint protection coating to protect porous material against watering staining chlorophyllon aquas based emulsion (Make Killick gaurd /Zycoseal Max /imper guard xp or equivalent) M.R. |
| 71 | Lime wash / Colour wash with matching original character manufacture to give an even shade : Two or more coats on new work M.R. |
| 72 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm DSR 13.46.1 |
| 73 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. DSR 13.80 |
| 74 | French spirit polishing with PU poilish : Two or more coats onold work and new works including a coat of wood filler M.R |
| 75 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture DSR 13.48.3 |
| 76 | Providing & Fixing of Knauf Fibre Glass Acoustical Suspended Ceiling System with 15 mm thick Optra Microlook 90 Edge Tiles with Knauf Suprafine 15mm face exposed grid. The tiles shall have smooth laminated visual with Humidity Resistance (RH) of 95%, NRC 0.85 – 0.95(Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, Light Reflectance ≥88% as per ASTM E-1477, Colour Pebble White/Black, Fire Performance of Class 0/1 as per BS 476 Part 6/7 with 15mm Square Tegular/Microlook 90˚ edge and 8mm drop in module size of 600 x 600mm. It shall be suitable for Green Building application, with Recycled content of 85%. SUSPENSION: The tile shall be laid on Knauf Suprafine 32 with 15 mm wide T - section flanges colour global white having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32mm (all sections). The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability.To ensure specification of tiles, Manufacturers Test Certificate is requiredhavingcomplete site address& duly signed by Manufacturer. INSTALLATION:To comprise main runner spaced at 1200mm securely fixed to the structural soffit using Knauf suspension system (specifications above) at 1200mm maximum. The First/Last Knauf suspension system at the end of each main runner shall not be greater than 450mm from the adjacent wall along with the first and the last main beam shall be at less than 600mm from the wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees.Perimeter trim to be Knauf wall angles of size 3000x19x19mm, secured to walls using screws at 450mm centre to centre maximum. Installation should be carried out as per Knauf recommended procedure and designs approved by the Architect/ Engineer-in-Charge. KNAUF SUSPENSION SYSTEM - accessories supplied by Knauf consisting of M6 Anchor Fasteners with hanger hole, pre-straightened hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum loading strength of 110 kgs. (Optionally, adjustable hook clips made of 0.7mm thick Grade 1 C55 galvanized spring steel of dimension 100 x 20mm and 4 mm aquiline wire to be used for level adjustment during installation purpose in main runners). APPROVED MAKE - Knauf Ceiling Solutions/ SAS International/Linderer M.R. |
| 77 | Providing &Fixing of KCS Mineral Fibre Acoustical Suspended Ceiling System with 15mm thick Sierra OP Tegular 15/90 Edge Tiles with KCS Silhouette 15mm face exposed grid. The tiles shall have smooth laminated visual with Humidity Resistance (RH) of 95%, NRC 0.85 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, CAC of 25db as per ASTM E1414, Light Reflectance ≥86% as per ASTM E-1477, Thermal Conductivity λ = 0.040 W/mK, Colour Global White, Fire Performance of class A2-s1, d0 according to EN 13501-1 with 15mm Tegular 15/90˚ edge and 8mm drop in module size of 600 x 600mm. The scrim on the face of the tile shall be cleanable and classified as ISO 14644-1 cleanroom class 5. It shall be suitable for Green Building application, with Recycled content of 43% VOC Emissions (French) class of A+. The tile shall have Environmental Product Declaration as per ISO 14025 and EN 15804+A2. The tile shall have certifications from GRIHA and GreenPro thereby confirming that it is an environment friendly product. To ensure specification of tiles, Manufacturers Test Certificate is required having complete site address & duly signed by manufacturer. SUSPENSION: The tile shall be laid on KCS Silhouette 38 profile grid system with 15mm white flanges incorporating a 6mm central reveal in white/black colour with mitred ends & “bird’s mouth” notches to provide mitred cruciform junctions colour global white (Matching to tile color).Grid shall have double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 7.9 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 9.5 kg/m. The end details of the cross tee shall be made of pre hardened steel clip fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of 90 gsm as per IS 277 (2003) pre-painted steel with baked polyester paint of 0T bending capability. INSTALLATION: To comprise main runner spaced at 1200mm securely fixed to the structural soffit using KCS suspension system (specifications below) at 1200mm maximum. The First/Last KCS suspension system at the end of each main runner shall not be greater than 450mm from the adjacent wall along with the first and the last main beam shall be at less than 600mm from the wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be KCS wall angles of size 3000x19x19mm, secured to walls using screws at 450mm centre to centre maximum. Installation shall be carried out as per KCS recommended procedure and designs approved by the Architect/ Engineer-in-Charge. Duly signed MTC need to be submitted. KCS SUSPENSION SYSTEM:- accessories supplied by KCS consisting of M6 Anchor Fasteners with hanger hole, pre-straightened hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum loading strength of 110 kgs. (Optionally, adjustable hook clips made of 0.7mm thick Grade 1 C55 galvanized spring steel of dimension 100 x 20mm and 4 mm aquiline wire to be used for level adjustment during installation purpose in main runners). APPROVED MAKE - Knauf (Armstrong)/ SAS International/Linderer. M.R. |
| 78 | Providing and Fixing Knauf SoundScapes Shapes - Acoustical clouds which are 30 mm thick, flat glass fibre panels of Humidity Resistance RH 95%, with embedded frame made of aluminium extruded section of 38X10mm of grade 6063-T6as per dimension mentioned in below table for reinforcement and secured hanging. Embedded extrusion shall have grub slot with pre inserted nut for group hanging and connected using Aluminium die casted corner connector with ¼” – 20 threading for hanging using cable adjuster for independent clouds. The form of SoundScapes Shapes - shall be Hexagon in standard Traffic White color with light reflectance 90% as per ASTM 1477-98 or in the color specified by the Architect / Engineer in charge (Shell / Tangerine / Cranberry / Moss / Kiwi / Reef / Lagoon). The SoundScapes Shape shall be made of Glass fibre panel withdensity of 110-120 Kgs/m3 along with acoustical sound absorbing scrim on the face to achieve sound absorption as per below mentioned table in accordance with EN ISO 354 :2003 (average of 500-4000Hz). The face and edges shall be finished with matching water-based texture paint. Individual Suspension The panel shall be hanged using deck hanging kit comprising of griper structure anchor & cap of dia. 20mm, spring loaded bottom end cable adjuster of dia. 9mm and 2.4m long aircraft cable of 1/16” dia. The number of deck hanger will be as per Table 1 above. Suspension System DetailsComponents 1) Griper structure anchor, 2) Gripper anchor cap 3) Cable adjuster 4) Aircraft Cable Cable adjuster Spring loaded bottom end cable adjuster of dia. 9mm and 45mm long Aircraft cable Material Galvanized Steel Aircraft cable dimension 1/16” Ø x 2.4m Tolerance ±1mm Group Installation Group installation shall be carried out using a secondary structure made of Group framing kit comprising of Aluminiumextruded U-shape section of dimension 25 x 25 x 3658 mm(L) having holes at the bottom at a pitch of 51mm for connecting section to each other in line / perpendicular using frame splice / frame alignment kit respectively. The panel shall be hanged to this secondary frame using panel hook for 50/75mm drop having height of 139 & 165mm / 165 & 190mm respectively. Suspension System Details Base material secondary frame Aluminium extrusion Frame section dimension 25 x 25 x 3658 mm(L) Connecting accessories. Frame splice kit, Frame alignment kit. Panel Hanging accessories Panel hook clip 50mm drop (139 & 165mm height) / Panel hook clip 75 mm drop (165 & 190mm height) Tolerance ±2mmINSTALLATION: Individual Suspension. The panels to be suspended individually using the Knauf SoundScapes Deck hanging kit as per the number specified in above Table 1. Hanger Wire Attachment to Structure: Attach the gripper structure anchor to the true ceiling using an appropriate fastener (1/4\\"-20 Threading) that will carry the full weight of the panels. Insert the end of the cable into the gripper anchor cap. Screw the gripper anchor cap completely into the gripper structure anchor. The panel to be suspended using the aircraft cables from the soffit by fixing the cap end of the cable to gripper structure anchors and the other end passing through the bottom end cable adjuster. The height & level of the panels can be adjusted using the bottom end cable adjusters. Suspend the SoundScapes Shape by locating and screwing the bottom end of the cable adjuster into the threading of the connector. The height & level of the panels can be adjusted using the bottom end cable adjusters. Installation should be carried out as per Knauf recommended procedure& designs as approved by Architect/Site-In-Charge. MTC Need to be submitted against respective supply. Group Installation The secondary frame needs to be constructed using Group Framing Kit by connecting them to each other in line / perpendicular using frame splice / frame alignment kit respectively.The plan of the frame shall be constructed as per the RCP of the SoundScapes Shapes grouping layout. Panel Hook clip need to be fixed to the embedded frame at appropriate marked location. Panel shall then be installed on the frame using the hook clip. Installation should be carried out as per Knauf recommended procedure& designs as approved by Architect/Site-In-Charge. MTC Need to be submitted against respective supply. APPROVED MAKE - Knauf (Armstrong)/ SAS ternational/Linderer. M.R. |
| 79 | Providing & fixing 10.5 mm thick engineerwood flooring american exotic bruce 7 layer construction,top layer of wood veener 2mm ,plank size width 120 mm ,length 400-1200 mm,Lock & fold locking ,premium finish,micro bevel edges/ends with an underlayment made of natural colour foam,with accessories like end profile,transition profile,reducer ,etc.complete.The profiles are 100% matching. profile at door openings Make-Armstrong/FloorMaster M.R. |
| 80 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes DSR 10.16.2 |
| 81 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads, landings etc. of stair cases, includinguse of chequered plate wherever required, all complete DSR 10.25.1 |
| 82 | Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarsesand(zone-III) : 4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits.50 mm thick DSR 5.18.1 |
| 83 | Providing and Fixing of GRC Jali (Glass Fibre Reinforced Jali) 35 mm thick of required size, pattern, design, and colour with 50% area covered to be fixed with structural steel work with Dry Fixing method.The jali shall be made from 53 grade White Portland Cement , Quartz, Fine Silica Sand, Alkali Resistant Glass Fibre , Super Plasticizers and UV Resistant Synthetic inorganic pigments . The material casting should take place in Synthetic Rubber / FRP mould manufactured by RECKLI or equivalent.NOTE : Any MS work for fixing of GRC Jali shall be paid extra. M.R. |
| 84 | Providing & Fixing of Bison Board with High tensity stone texture including all necessary T&P & Required material all complete in direction of Engineer in charge. M.R. |
| 85 | Providing & Fixing of 10mm 4 Wall Opal White Polycarbonate Sheet Weight 1.8 Kg. Per Sqmtr. With 50 Micron Both side UV coated to maintain the yellow Index the sheet manufactured under BIS 14443 Minimum cold bending radius 1500mm, Heat Transfer Coefficient Ug 2.5 w/m2k Coefficient of thermal 0.065 mm/m C Maximum Service temp. without load 120° C, Brand: ULTRALITE/Makrolon/Lexan Sheet fixing with 60mm Aluminium Alcox top & bottom section Minimum weight 1.1 kg. P. Rmtr. with EPDM Rubber Gasket. Over mild steel Pipe parallel to sloping direction, with silicon sealant to avoid leakage. With end profile, Slop over mild steel sectionand all necessary T&P etc all complete in direction of engineer in charge. (Make Ultralite/ Makrolon/ Lexan) M.R. |
| 86 | Providing & filling of Cinder in sunken portion as per drawing etc all complete in direction of engineer In charge. M.R. |
| 87 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. DSR 22.7.1 |
| 88 | Providing and fixing horizontal chajja of stone 40 mm thick and upto 80 cm wide projection in lime mortar 1:2 (1 lime : 2 coarse sand) including pointing in lime mortar 1:2 (1 lime : 2 stone dust) with an admixture of pigment matching the stone shade A. R. 10.13 |
| 89 | Repair of Wooden Door & Window frame including remvoal of doors & window etc all complete in direction of engineer in charge Material & Design as per Orriginal Site Condition M.R. |
| 90 | Repairing of door shutter including necessary Damage wooden member & Panel (Material as per original site condition )& Design as per exisiting woooden doors including door panel removal & after repair Fixing etc all complete in direction of engineer /conservation architect in charge. M.R. |
| 91 | Providing and fixing red sand stone brackets 55x22.5x45 cm sunk and moulded including providing and fixing with 4 Nos gun metal cramp 25x6 mm 30 cm long and dowel bars 7.5 cm long 6 mm dia as per design A.R.10.11 |
| 92 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) 9.72.1 |
| 93 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 100x85x5.5 mm (heavy type 9.72.3 |
| 94 | Providing and fixing brass L- drop includibg brass screw etc M.R |
| 95 | Providing and fixing soil, waste and vent pipes : 100 mm dia Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 100 mm DSR17.35.1.3 |
| 96 | Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe 100 mm diaSS 304 grade coupling with EPDM rubber gasket 17.57A.1.1 |
| 97 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : For 100 mm dia pipe 17.37.1 |
| 98 | Brick work with bricks of class designation 150 in superstructure up to two level Lime mortar 1:1:1 (1 Lime putty:1 surkhi: 1 fine sand) Intach 5.5 |
| 99 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : second class takewood panell DSR 9.7.7.31 |
| 100 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : Float glass panes 5 mm thick glass pane (weight not less than 10kg/sqm) DSR 9.7.7.2 |
| 101 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. DSR 11.4 |
| 102 | Providing and fixing glass strips in joints of terrazo / cement concrete floors - 40mm wide and 4mm thick DSR11.13.1 |
| 103 | Providing and mixing powdered colour oxides in the top 12 mm thick layer of the Cement Hardener. As suggested by the Conservation/Site Architect and Engineer. M.R |
| 104 | Providing and placing of anchors in cored holes of predefinedlengths, diameters & locations obtained as output fromanalysis of the simulated model of the bridge using existingmaterial properties and geometrical conditions Coring shouldbe done by use of high speed low vibratory coring machinewith diamond core bits. It should impart minimal or novibration to the structure being strengthened. The coringmotor & bit should be capable to core at least upto 3m instraight line. Each patented anchor will comprise of threecomponents(Except Cintec RAC anchor which does not containany separate grout delivery pipe) detailed as below:(a) Reinforcing Member:- Stainless steel Rebar/studd/tube ofGrade 304 conforming to BS 6323/6744/6105 & ASTMA554/A312 as per applicability. The diameter and size of thereinforcing members will based upon the structuralrequirement of structure. (b) Presstec Grout:- The Presstec grout is a one component dry powder mix. Its basic ingredient includes natural mineral and portlandproduct with graded aggregates, including sand and lime. The constituents, whenproportioned with water, produce a pumpable, non-shrinking grout. The grout does not contain any epoxy & resin binders. Presstec grout is aproprietary, pure mineral grout, conforming to German DINstandards.(i) DIN 1045(ii) DIN 18200(iii) DIN 18555(iv) DIN 18557(c) Sock:- This should be a specially woven polyester basedtubular sock with expansion properties to suit the diameter ofthe bore hole in the substrate. The sock should have propertto expand in lateral direction only. The mesh of the sock is tobe designed to contain the aggregates of mixed grout whilestill allowing the milk of grout to flow from its pores. Annexure ICintec Anchor Rate List(d) Grout Delivery Pipe:- A 10-12mm dia. PVC hollow pipe fordelivery of grout under pressure inside the sock & around thereinforcing rebar/stud such that the grout inflates the sock allarond the rebar/stud starting from far inside end, movingoutward towards the front & forming mechanical bondbetween rebar/stud & substrate. Inatch Cintec RAC Anchor of 10mm diameter hollow stainless steel tube in cored hole of 32mm diameter and upto maximum length of 1000mm |
| 105 | Providing and placing of anchors in cored holes of predefinedlengths, diameters & locations obtained as output fromanalysis of the simulated model of the bridge using existingmaterial properties and geometrical conditions Coring shouldbe done by use of high speed low vibratory coring machinewith diamond core bits. It should impart minimal or novibration to the structure being strengthened. The coringmotor & bit should be capable to core at least upto 3m instraight line. Each patented anchor will comprise of threecomponents(Except Cintec RAC anchor which does not contain any separate grout delivery pipe) detailed as below:(a) Reinforcing Member:- Stainless steel Rebar/studd/tube ofGrade 304 conforming to BS 6323/6744/6105 & ASTMA554/A312 as per applicability. The diameter and size of thereinforcing members will based upon the structuralrequirement of structure. (b) Presstec Grout:- The Presstec grout is a one component dry powder mix. Its basic ingredient includes natural mineral and portlandproduct with graded aggregates, including sand and lime. The constituents, whenproportioned with water, produce a pumpable, non-shrinking grout. The grout does not contain any epoxy & resin binders. Presstec grout is aproprietary, pure mineral grout, conforming to German DINstandards.(i) DIN 1045(ii) DIN 18200(iii) DIN 18555(iv) DIN 18557(c) Sock:- This should be a specially woven polyester basedtubular sock with expansion properties to suit the diameter ofthe bore hole in the substrate. The sock should have propertto expand in lateral direction only. The mesh of the sock is tobe designed to contain the aggregates of mixed grout whilestill allowing the milk of grout to flow from its pores. Annexure ICintec Anchor Rate List(d) Grout Delivery Pipe:- A 10-12mm dia. PVC hollow pipe fordelivery of grout under pressure inside the sock & around thereinforcing rebar/stud such that the grout inflates the sock allarond the rebar/stud starting from far inside end, movingoutward towards the front & forming mechanical bondbetween rebar/stud & substrate. Inatch Cintec Anchor of 10mm diamter Rebar/studd in cored hole of 32mm diameter. |
| 106 | Providing and placing of anchors in cored holes of predefinedlengths, diameters & locations obtained as output fromanalysis of the simulated model of the bridge using existingmaterial properties and geometrical conditions Coring shouldbe done by use of high speed low vibratory coring machinewith diamond core bits. It should impart minimal or novibration to the structure being strengthened. The coringmotor & bit should be capable to core at least upto 3m instraight line. Each patented anchor will comprise of threecomponents(Except Cintec RAC anchor which does not contain any separate grout delivery pipe) detailed as below:(a) Reinforcing Member:- Stainless steel Rebar/studd/tube ofGrade 304 conforming to BS 6323/6744/6105 & ASTMA554/A312 as per applicability. The diameter and size of thereinforcing members will based upon the structuralrequirement of structure. (b) Presstec Grout:- The Presstec grout is a one component dry powder mix. Its basic ingredient includes natural mineral and portlandproduct with graded aggregates, including sand and lime. The constituents, whenproportioned with water, produce a pumpable, non-shrinking grout. The grout does not contain any epoxy & resin binders. Presstec grout is aproprietary, pure mineral grout, conforming to German DINstandards.(i) DIN 1045(ii) DIN 18200(iii) DIN 18555(iv) DIN 18557(c) Sock:- This should be a specially woven polyester basedtubular sock with expansion properties to suit the diameter ofthe bore hole in the substrate. The sock should have propertto expand in lateral direction only. The mesh of the sock is tobe designed to contain the aggregates of mixed grout whilestill allowing the milk of grout to flow from its pores. Annexure ICintec Anchor Rate List(d) Grout Delivery Pipe:- A 10-12mm dia. PVC hollow pipe fordelivery of grout under pressure inside the sock & around thereinforcing rebar/stud such that the grout inflates the sock allarond the rebar/stud starting from far inside end, movingoutward towards the front & forming mechanical bondbetween rebar/stud & substrate. Inatch Cintec Anchor of 10mm diamter Rebar/studd in cored hole between 32mm and 40mm diameter. |
| 107 | Providing and placing of anchors in cored holes of predefinedlengths, diameters & locations obtained as output fromanalysis of the simulated model of the bridge using existingmaterial properties and geometrical conditions Coring shouldbe done by use of high speed low vibratory coring machinewith diamond core bits. It should impart minimal or novibration to the structure being strengthened. The coringmotor & bit should be capable to core at least upto 3m instraight line. Each patented anchor will comprise of threecomponents(Except Cintec RAC anchor which does not containany separate grout delivery pipe) detailed as below:(a) Reinforcing Member:- Stainless steel Rebar/studd/tube ofGrade 304 conforming to BS 6323/6744/6105 & ASTMA554/A312 as per applicability. The diameter and size of thereinforcing members will based upon the structuralrequirement of structure. (b) Presstec Grout:- The Presstec grout is a one component dry powder mix. Its basic ingredient includes natural mineral and portlandproduct with graded aggregates, including sand and lime. The constituents, whenproportioned with water, produce a pumpable, non-shrinking grout. The grout does not contain any epoxy & resin binders. Presstec grout is aproprietary, pure mineral grout, conforming to German DINstandards.(i) DIN 1045(ii) DIN 18200(iii) DIN 18555(iv) DIN 18557(c) Sock:- This should be a specially woven polyester basedtubular sock with expansion properties to suit the diameter ofthe bore hole in the substrate. The sock should have propertto expand in lateral direction only. The mesh of the sock is tobe designed to contain the aggregates of mixed grout whilestill allowing the milk of grout to flow from its pores. Annexure ICintec Anchor Rate List(d) Grout Delivery Pipe:- A 10-12mm dia. PVC hollow pipe fordelivery of grout under pressure inside the sock & around thereinforcing rebar/stud such that the grout inflates the sock allarond the rebar/stud starting from far inside end, movingoutward towards the front & forming mechanical bondbetween rebar/stud & substrate. Inatch Cintec Anchor of 12mm diamter Rebar/studd in cored hole of 32mm |
| 108 | Providing and Fixing 10 mm thick false ceiling with plaster of paris with murga jali in true horizontal level, suspended on interlocking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid , resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I.slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mmdia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods withgalvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. MR |
| 109 | Extra for providing plaster of Paris (Gypsum anhydrous) ceiling above 5 metres height from floor level. MR |
| 110 | Providing and fixing of metal framework for curved/designer false ceiling, including GI perimeter channels (0.5mm thick) fixed to walls/partitions, intermediate channels at 1200mm c/c, and ceiling sections at 450mm c/c. The framework shall be bent and shaped to achieve the desired radius/curvature as per architectural drawings, suspended from the RCC slab using GI hangers and expansion fasteners, perfectly leveled and braced for structural stability.\\" MR |
| 111 | Providing and executing fresco painting artwork on curved ceiling surface using natural dye colours, over properly prepared lime plaster base, adopting traditional fresco technique, including surface preparation, scaffolding, detailing and final finishing, complete in all respects as per approved drawings, specifications and directions of Engineer-in-Charge.” MR |
| 112 | Providing & fixing of Beveled Glass as per drawing & design etc all complete in direction of engineer in charge M.R. |
| 113 | Providing & Fixing of beamsinlcuiding hosting, fixing in position and applying wood preservative for the unexposed surfaces etc. Complete with sal wood DSR 9.54.1 |
| 114 | Providing and installing stone finials on roof dome and grouting with S.S. pins. M.R. |
| 115 | Shifting of almirah from Ground Floor to First Floor by manual or machine, including loading, unloading and proper handling, ensuring safe transfer without any damage, complete. M.R. |
| 116 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.Two coats 13.82.2 |
| 117 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matchingpigment etc, complete. DSR 11.37 |
| 118 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottlegreen, black of any size as approved by Engineer-in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. DSR 8.31 |
| 119 | Creating a HeliBeam using Helibars 6mm: Providing and fixing of Helifix make Hi-fin reinforcement Helibars of 6mmdia, double bars in one slot, MOC austenitic stainless steelas per ASTM 304, having cross-section area of 8 sq.mm,pitch 29/30, with UTS 980 N, shear strength 5.5 kN, along with Helibond grout, a special cementitious grout with lowexpansion, non-gassing and injectable with exceptionalthixotropic properties. Including chasing of bed joints forHeliBars in brick/stone/block masonry, cleaning anddampening with water to achieve good bonding of HeliBar with HeliBond grout in the slot of masonry ensuring that it remains tight at the joint after curing as per instructionS provided by Structure Engineer / Helifix, excluding Staging& Scaffolding, at places wherever necessary Inatch |
| 120 | Crack stitching using HeliBar 6mm: Providing and fixing of Helifix make Hi-fin reinforcement Helibars of 6mm dia, single bar in one slot, MOC Austenitic stainless steel as per ASTM 304, having cross section area of 8 sq.mm , pitch 29/30, with UTS 9.8 kN, shear strength 5.5 kN, along with Helibond grout, a special cementitious grout with low expansion, non gassing and injectable with exceptionalthixotropic properties. Including chasing of bedjoints for HeliBars in brick/stone/block masonry, cleaning anddampening with water to achieve good bonding of HeliBarwith HeliBond grout in the slot of masonry ensuring that it remains tight at the joint after curing as per instructionsprovided by Structural Engineer / Helifix, all aboveexcluding staging & scaffolding, at places wherevernecessary. |
| 121 | Pinning using CemTie 8mm: Providing and fixing of Helifix make Hi-Fin reinforcement pins - CemTie having 8mm Dia and specified length. MOC. austenitic stainless steel as per ASTM 304, having cross section area of 10.5 mm², pitch 38/40, with UTS 13.7 KN as per structural drawing & design in the brick/stone masonry wall. Drilling a 16 to 18mm dia hole by mechanical means at marked positions at the required angle and to the specified depth from the outer face of the wall. Cleaning out all dust from the hole and thoroughly flushing with water, ensuring the hole is damp or primed prior to inserting the nozzle. Attach the required length of CemTie pinning Nozzle to the gun and grout the same with Helifix make Helibond grout, a special cementious grout with low expansion, non-gassing and injectable with exceptional thixotropic properties having compressive strength of 45 N/mm² at 28 days, is to be used to bond the stainless steel Hi-fin reinforcement bars and pins with the help of pressure gun to be injected in the drilled holes of masonry, ensuring that it remains tight after setting as directed by structural engineer / Helifix. All above excluding taging/scaffolding, at places wherever necessary. MR |
| 122 | CrackBond TE 250: Providing & fixing of CrackBond TE250ml an injectable special purpose non shrink thixotropic epoxy resin with the help of manual pressure applicator and nozzle, including opening of crack, cleaning and ensuring sealing of cracks of 2mm - 12mm width upto a maximum depth of 150mm. |
| 123 | Providing and fixing decorative wooden display stand / lectern made of seasoned hardwood, duly carved and polished, complete with adjustable book holding arrangement, sturdy base, all fittings and accessories, finished with melamine / PU polish, complete in all respects as directed by Engineer-in-Charge. MR |
| 124 | SICT of Touch Kiosk Horizontal 43 inch Digital Standee High-Resolution Screens - 43 Inch IPSA+ Grade Display (Touch)(HDTK43) MR |
| 125 | SICT of MULTIFX Touch Kiosk Horizontal Digital Standee High-Resolution Screens 32 inch with I5 5257U 4GB RAM+128GBSSD MR |
| 126 | Providing and installing one (1) Calligraphy Printer complete in all respects.(Intelligent Automatic DIY XY ploter Writing Robot Automatic Copying Typewriter Writing Lesson Plans Painting Imitation Handwriting Copying CNC Router Drawing Machine Working Area A4) MR |
| 127 | Providing, supplying and fixing floor mounted museum display stand made of MS frame with decorative ornamental border, fitted with framed portrait / information panel, supported on rigid vertical members with heavy duty base, finished with powder coating / enamel paint, complete in all respects as directed by Engineer-in-Charge.” MR |
| 128 | Providing & applying Canvas Painting as direction of E/I MR |
| 129 | Providing, supplying and fixing wall mounted decorative manuscript scroll display made of printed / written parchment look sheet, fitted with wooden rollers at top and bottom, suspended with suitable hooks / fasteners, including complete mounting accessories, finished to approved design and colour, complete in all respects as directed by Engineer-in-Charge.” MR |
| 130 | Providing & Fixing Wooden Podium made by Teak Wood & Natural polish (22”(W) X 17”(D) X 44”(H) MR |
| 131 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings /wooden frames with rawl plugs screws etc. DSR 9.48.2 |
| 132 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. DSR 9.82 |
| 133 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.Two coats 13.82.2 |
| 134 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) 9.72.1 |
| 135 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 100x85x5.5 mm (heavy type 9.72.3 |
| 136 | Wiring point for light with 1.5 sq.mm FRLSH P.V.C. insulated multistrand single core Copper Conductor cable in P.V.C. conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting complete with 1.5 sq mm FR P.V.C. insulated multistrand single core Copper Conductor cable as earth wire drawn inside & modular type switch and ceiling rose/angle/batten holder on 3 mm thick phinolic laminated backelite sheet etc complete in all respects as directed including matching colour wash. UP SOR (ELEC) 2018 - 138 (C)+187(A) |
| 137 | Wiring point for two way light with 1.5 sq.mm FRLSH P.V.C. insulated multistrand single core Copper Conductor cable in P.V.C. conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting complete with 1.5 sq mm FR P.V.C. insulated multistrand single core Copper Conductor cable as earth wire drawn inside & modular type switch and ceiling rose/angle/batten holder on 3 mm thick phinolic laminated backelite sheet etc complete in all respects as directed including matching colour wash. UP SOR (ELEC) 2018 - 139 (C)+187(B) |
| 138 | Wiring point for fan. and light duty exhaust fan with 1.5 sq.mm FRLSH P.V.C. insulated multistrand single core Copper Conductor cable in P.V.C. conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting complete with 1.5 sq mm FR P.V.C. insulated multistrand single core Copper Conductor cable as earth wire drawn inside & modular type switch and ceiling rose/angle/batten holder on 3 mm thick phinolic laminated backelite sheet etc complete in all respects as directed including matching colour wash UP SOR (ELEC) 2018- 140 (C)+187(A) |
| 139 | Wiring point for 5 amp plug point with 1.5 sq.mm FRLSH P.V.C. insulated multistrand single core Copper Conductor cable in P.V.C. conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting complete with 1.5 sq mm FR P.V.C. insulated multistrand single core Copper Conductor cable as earth wire drawn inside & modular type switch and ceiling rose/angle/batten holder on 3 mm thick phinolic laminated backelite sheet etc complete in all respects as directed including matching colour wash UP SOR (ELEC) 2018 - 141 (C)+187(C) |
| 140 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. A.R. DSR - 2018 (E & M) -1.56 |
| 141 | Supply & fixing of power plug with 20 amp 250 volts flush type Modular switch & 5 pin 20 amp 250 volts flush type universal modular socket switch on concealed M.S. box including supply of all material,labour T&P etc. required for proper completion of work. UP SOR (ELEC) 2018 - 1139 (A) |
| 142 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. A.R. DSR - 2018 (E & M) -1.26 |
| 143 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. (GROUP-C) A.R. DSR 2018 (E&M)-1.54.3 |
| 144 | Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc as required Telephone Socket outlet A.R. DSR 2018 (E&M) -1.24.6 |
| 145 | Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc as required TV Antenna Socket outlet A.R. DSR 2018 (E&M) -1.24.7 |
| 146 | Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc as required CAT6 information outlet socket MR-EL-LV-1 |
| 147 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm) A.R. DSR(E&M) 2018 -1.27.1 |
| 148 | Supply & wiring of sub main with FR P.V.C. insulated 1100 volts grade single core copper conductor cable in heavy gauge P.V.C. coduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting complete with FR PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit.2 x 1.5 sq. mm. With 1 x 1.5 sq.mm. Earth wire In 20 mm dia conduit. UP SOR (ELEC) 2018 - 1313 (C) |
| 149 | Supply & wiring of sub main with FR P.V.C. insulated 1100 volts grade single core copper conductor cable in heavy gauge P.V.C. coduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting complete with FR PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit.2 x 4 sq. mm. With 1 x 2.5 sq.mm. Earth wire In 20 mm dia conduit. UP SOR (ELEC) 2018 - 221 (C) |
| 150 | Supply & wiring of sub main with FR P.V.C. insulated 1100 volts grade single core copper conductor cable in heavy gauge P.V.C. coduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting complete with FR PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit.2 x 6 sq. mm. With 1 x 4 sq.mm. Earth wire In 25 mm dia conduit. UP SOR (ELEC) 2018 - 222 (C) |
| 151 | Supply & wiring of sub main with FR P.V.C. insulated 1100 volts grade single core copper conductor cable in heavy gauge P.V.C. coduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting complete with FR PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit.2 x 10 sq. mm. With 1 x 6 sq.mm. Earth wire In 32 mm dia conduit. UP SOR (ELEC) 2018 - 224 (C) |
| 152 | Supply & wiring of sub main with FR P.V.C. insulated 1100 volts grade single core copper conductor cable in heavy gauge P.V.C. coduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting complete with FR PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit.4 x 6 sq. mm. With 2 x 4 sq.mm. Earth wire In 32 mm dia conduit. UP SOR (ELEC) 2018 - 277(C) |
| 153 | Supply & wiring of sub main with FR P.V.C. insulated 1100 volts grade single core copper conductor cable in heavy gauge P.V.C. coduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting complete with FR PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit.4 x 10 sq. mm. With 2 x 6 sq.mm. Earth wire In 32 mm dia conduit. UP SOR (ELEC) 2018 - 278 (C) |
| 154 | Supply & wiring of sub main with FR P.V.C. insulated 1100 volts grade single core copper conductor cable in heavy gauge P.V.C. coduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting complete with FR PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit.4 x 16 sq. mm. With 2 x 10 sq.mm. Earth wire In 40 mm dia conduit. UP SOR (ELEC) 2018 - 279 (C) |
| 155 | Supply and laying of heavy duty PVC conduit complete with bend and other accessories as required and 14 S.W.G. fish steel wire etc. in slab alongwith reinforcement before concreting and plastering complete in all respects.25 mm dia. conduit UP SOR (ELEC) 2018 - 282(A) |
| 156 | Supply and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/recessed steel/PVC conduit as required.1 run of cable A.R. DSR(E&M) 2018-1.53.1 |
| 157 | S/F of surface / flush mounting SPN Distribution board with additional metal door without MCB complete in all respects as directed at site by Engineer-in-charge.12 WAYSCAT A UP SOR (ELEC) 2018 -1025 (A) |
| 158 | S/F of surface/flush mounting TPN distribution board with additional metal door without MCB complete in all respect as directed at site by Engineer-in-charge..4 WAYS CAT A UP SOR (ELEC) 2018 -1026 (A) |
| 159 | S/F of surface/flush mounting TPN distribution board with additional metal door without MCB complete in all respect as directed at site by Engineer-in-charge..6 WAYS CAT A UP SOR (ELEC) 2018 -1027 (A) |
| 160 | Supply & fixing of 6/10/16/20/25/32 amp. SP MCB (10 KA) CAT A UP SOR (ELEC) 2018 -1002 |
| 161 | Supply & fixing of 6 Amp to 32 Amp DP MCB (10 KA) CAT A UP SOR (ELEC) 2018 -1009 |
| 162 | Supply & fixing of 40 Amp DP MCB (10 KA) CAT A UP SOR (ELEC) 2018 -1010 |
| 163 | Supply & fixing of 32 Amp FP MCB (10 KA) CAT A UP SOR (ELEC) 2018 -1019 |
| 164 | Supply & fixing of 40 Amp FP MCB (10 KA) CAT A UP SOR (ELEC) 2018 -1020 |
| 165 | S/F of 63 amp FP MCB (10 K.A.) CAT A UP SOR (ELEC) 2018 -1020 (A) |
| 166 | Supplying & fixing single pole, blanking plate in the existing MCB DB complete etc. as required. UP SOR (ELEC) 2018 -1034 (B) |
| 167 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 Amp. DSR 2018 (E&M)-2.14.2 |
| 168 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB FP complete with connections, testing and commissioning etc. as required. 40 Amp. A.R. DSR 2018 (E&M)-2.15.2 |
| 169 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB FP complete with connections, testing and commissioning etc. as required. 63 Amp. A.R. DSR 2018 (E&M)-2.15.3 |
| 170 | Erection and testing of ceiling fan and regulator etc excluding supply of down rod, complete in all respect. UP SOR (ELEC) 2018 - 1115 |
| 171 | Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc complete in all respects. UP SOR (ELEC) 2018- 1120 |
| 172 | Supply & fixing of Fan regulator, dimmer, 250/300 watt, ISI marked, on the existing switch board including making connections, required material, labour T/P etc. for proper completion of work to the satisfaction of Engineer of work. UP SOR (ELEC) 2018 - 1203 |
| 173 | Supply and burying earth electrode for lightning conductor of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe for watering funnel, 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineerin-charge complete in all respect.UP SOR (ELEC) 2018 - 706 |
| 174 | Supply and fixing of horizontal air termination (roof conductor) of 25mm x 3mm G.I. strip, G.I. clamps on surface complete in all respects as approved by Engineerin-charge. UP SOR (ELEC) 2018 - 710 |
| 175 | Supply and fixing of vertical air termination final rod comprising of 300mm long x 25mm dia. GI rod with one pointed prong and 100mm dia x 3 mm thick base plate etc. complete in all respect. UP SOR (ELEC) 2018 - 712 (A) |
| 176 | Supply and laying of 32 mm x 6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect. UP SOR (ELEC) 2018 - 717 |
| 177 | Supply and fixing of testing joint of G.I. strip 32mm x 6mm and 150mm long with G.I. bolts and nut etc. complete in all respect. UP SOR (ELEC) 2018 - 719 |
| 178 | Design, manufacture, supply, testing and commissioning of Main Panel fabricated out of 14 SWG CRCA sheet steel, IP 42, wall / floor mounting type. The sheet steel shall undergo minimum 9 tank treatment followed by finishing powder coating of min 60 micron thickness. the board includes 415 V electrolitic Aluminium Bus Bar, removable gland plates, cable glands, including connection with outgoing feeders complete in all respect. The incoming MCCB shall be microprocessor based with inbuilt O/L & S/C release with inbuilt E/F protection and all Outgoings MCCB's shall be thermal-magnetic based with inbuilt O/L & S/C release.All MCCB's shall be Ics = 100% Icu, with rotary handle & pad locking arrangement, with adjustable O/L & S/C trip setting as per load requirement. All TP MCCB shall be with solid isolable neutral link. The breaking capacity specified is Ics value. All outgoing MCB's shall be C type with 10 KA breaking capacity.The Panel shall have a provision for AUTOMATIC FIRE DETECTION GAS SUPPRESSION flooding system for complete panel of each compartment / section including gas bank of required capacity (Note - Gas Supression flooding sysytem having seperate item).The above board shall be complete with 3 nos. phase indicating lights, flush mounted Ammeter, Voltmeter, CT's, PT's, selector switches, protective fuses etc. at Incomer with all inter connections by min. 2.5 sq.mm. Copper wires. INCOMER : 630 AMP FP MCCB (25 KA)BUS BAR : 600 AMP, 500 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium bus bar with conductivity of min 57 to 58% of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 1.00 sq mm / amp.The Maximum allowable temperature for the Bus bar to be restricted to 85 deg C. The temperature rise should be restricted to 35 deg C above ambient temperature.OUT GOINGS :42 nos 32 AMP FP MCB (10 KA) 6 nos 32 AMP FP MCB (10 KA) M.R. |
| 179 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sqmm FR PVC insulated copper conductor single core cable in surface wooden Batten, with Traditional switch, Traditional plate, suitable wooden box and earthing the point with 1.5 sqmm FR PVC insulated copper conductor single core cable etc. as required.(Goup C) (Make:- SSK Heritage Series or Equivalent) M.R. |
| 180 | Supply and fixing of suitable size Wooden Box with Traditional plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps. Traditional socket outlet and 5/6 amps. switch, connection, painting etc. as required. (Make:- SSK Heritage Series or Equivalent) M.R. |
| 181 | Supply and fixing of suitable size GI box with Traditional plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6 amps. Traditional socket outlet and 15/16 amps. Traditional switch, connection, painting etc. as required. (Make:- SSK Heritage Series or Equivalent) M.R. |
| 182 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing & fixing 3pin 20 amps modular socket outlet and 20 amps mini SP MCB 3 KA (for ac & gyser), connection, painting etc. as required. M.R. |
| 183 | Supplying & drawing 2 pair, 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing wooden Batten as required. M.R. |
| 184 | Supply and fixing of following sizes of wooden Batten along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required :20 to 40mm M.R. |
| 185 | Supplying and fixing following Traditional switch/ socket with Traditional plate & switch box including connections etc. as required. (Make:- SSK Heritage Series or Equivalent)Telephone socket outlet M.R. |
| 186 | Supplying and fixing following Traditional switch/ socket with Traditional plate & switch box including connections etc. as required. (Make:- SSK Heritage Series or Equivalent) Computer Jack for RJ-45 Socket M.R. |
| 187 | Supply and fixing of Traditional Type stepped type electronic fan regulator on the existing Traditional Type switch box including connections but excluding Traditional Type plate etc. as required. (Make:- SSK Heritage Series or Equivalent) M.R. |
| 188 | Supply and fixing Traditional Type blanking plate on the existing Traditional plate & switch box excluding Traditional plate as required. (Make:- SSK Heritage Series or Equivalent) M.R. |
| 189 | Supply, installation, testing & commissioning of following pairs of IDF having LSA-Plus disconnection module, back mounting frame & wire manager on good quality power coated MS box with lock & keys.10 Pair M.R. |
| 190 | Supply and fixing of recess/ Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect.UP SOR (ELEC) 2018 - 1401 CAT- AAA |
| 191 | Supply and fixing of recess/ Surface/ Pendent mounting round 10 to 15 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect.UP SOR (ELEC) 2018 - 1402 CAT- AAA |
| 192 | Supply and fixing of 55 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing with body with extended heat sink, diffuser of Polycarbonate meterial and driver set complete in all respect. UP SOR (ELEC) 2018 - 1407 CAT- AAA |
| 193 | Supply and fixing of 12 Watt to 15 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing with extended heat sink, diffuser of Polycarbonate meterial and driver set complete in all respect. UP SOR (ELEC) 2018 - 1410 CAT- AAA |
| 194 | Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. UP SOR (ELEC) 2018 - 1413 CAT- AAA |
| 195 | Supplying, installation, testing and commissioning of decorative ceiling-hung chandelier light fitting with metal body and glass shades, complete with chain suspension, ceiling rose, lamp holders, LED lamps, internal wiring, fixing accessories, and making good the surface, as approved by Engineer-in-Charge MR |
| 196 | Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.17.1.1 |
| 197 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.17.1.2 |
| 198 | Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.17.1.4 |
| 199 | Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required17.1.5 |
| 200 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.17.1.7 |
| 201 | Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & peaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required17.1.8 |
| 202 | Supplying, installation, testing & commissioning of maincontrol and indicating panel made out of 16 SWG MS sheetto accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required.10 Zone panel for fire alarm system 250 Watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required - 2 Nos.(one to act as standby)Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set.Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc. complete as required -1 set. Amplifier change over switch for inter changing amplifier -1 No.Monitor panel for loudspeaker complete with output selector, ON/OFF switch, fuse, visual indications etc. complete as required- 1 No.Gooseneck microphone with stand and ON/OFF switch- 1 No.Main ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters, terminal blocks etc. complete as required -1 set.Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos.12 volt, 60 AH each sealed maintenance free batteries -1 set.17.1.10 |
| 203 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm. 1.21.2 |
| 204 | Supplying, receiving, storing, handling, fixing, wiring for fire alarm system wiring using ISI marked (IS 694) 1100 Volts grade, PVC insulated, flexible, flame retardant low smoke (FRLS) copper conductor wire, drawn in existing solid / flexible conduits / casing caping including connections to the detectors, manual call points, hooters, response indicators, accessories, fire alarm control panel etc. including termination with bottle type copper lugs, connectors etc as required to complete the system. 2 x 1.5 sq mmMR |
| 205 | Supply and laying of ISI marked Copper conductor PVC insulated FRLS control cable as per IS 1554 or XPLE insulated as per IS 7098 PVC sheathed 1100 volts grade. On surface the cable run shall be fixed by GI clamps etc. of suitable size or on existing cable tray complete in all respect .The armouring of the cable shall be properly connected with the earth conductor including fixing of palm or pin type copper tin plated cable socket (lug) to the cable leads, glands, connectors, junction box, insulating with tape and making connections complete in all respect including supply of clamps, lugs, glands, JB, tape etc complete upto the satisfaction of Engineer-in-charge. 6 x 1.5 sq mm armouredMR |
| 206 | Providing and fixing of self illuminated / auto glow \\"EXIT\\" signs printed on photoluminescent sheet containing self illuminated base chemical, of appropriate size not less than 300 x 150 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site. MR |
| 207 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern DSR 16.91.2. |
| 208 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. DSR 13.80 |
| 209 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm DSR 13.46.1 |
| 210 | Providing & Fixing of 10mm 4 Wall Opal White Polycarbonate Sheet Weight 1.8 Kg. Per Sqmtr. With 50 Micron Both side UV coated to maintain the yellow Index the sheet manufactured under BIS 14443 Minimum cold bending radius 1500mm, Heat Transfer Coefficient Ug 2.5 w/m2k Coefficient of thermal 0.065 mm/m C Maximum Service temp. without load 120° C, Brand: ULTRALITE/Makrolon/Lexan Sheet fixing with 60mm Aluminium Alcox top & bottom section Minimum weight 1.1 kg. P. Rmtr. with EPDM Rubber Gasket. Over mild steel Pipe parallel to sloping direction, with silicon sealant to avoid leakage. With end profile, Slop over mild steel sectionand all necessary T&P etc all complete in direction of engineer in charge. (Make Ultralite/ Makrolon/ Lexan) M.R. |
| 211 | Supply and fixing of Prefabricated Kiosk M.R. |
| 212 | Supply and fixing of Avika Bamboo Cane Chairs | Kursi | Garden Chairs |Living Room, Dining Room,Cafe Chair,restaurent M.R. |
| 213 | Supply and fixing of Cane Bamboo Round Coffee & Tea Table for Home, Office, Balcony, Room, and Garden M.R. |
| 214 | Supply and fixing of Natural and Handmade Wood, Bamboo, Cane Oval Table, Coffee Table, Center M.R. |
| 215 | Supply & Fixing of’ 5mtr long Antique designed pole with cast aluminium/iron base with galvanized steel pipe and decorative top painted with primer then painted with dull finished polyurethane paint fitted with MCB and connector with decorative bracket single arm for mounting of 1nos drop down lantern with body made out of spun aluminium and fitted with poly carbonate diffuser in 110W with built in surge protector and lumn output>110lmn/watt. Design as per Architect in charge. M.R. |
| 216 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipeof 2.7 metre long etc. with charcoal/ coke and salt as required DSR 5.6 (E&M) |
| 217 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. DSR 5.7 (E&M) |
| 218 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brassnut bolt & spring washer spaced at 50mm) DSR 5.8 (E&M) |
| 219 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 6.00 Sqmm 4 Core PWD 501(g) |
| 220 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 25.00 Sqmm 3.5 Core PWD 501 (J) |
| 221 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 70.00 Sqmm 3.5 Core PWD 501 (M) |
| 222 | Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc. The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp on incoming etc. The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A B & B-II and pedestal type for Cat-B and C only Incoming 200 Amp. TPN-1 No Outgoing 100 Amp. TPN-1 No and 63 Amp. TPN-3 Nos. Cat. B. Cubicle Type PWD 802 C |
| 223 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect.40 A TPN PWD 807 f |
| 224 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) DSR 14.15.1 |
| 225 | Supply and fixing of decorative 8 to 16 Watt LED bollard luminaire with driver set confirming to IP 65 protection complete in all respect.CAT-AAA PWD 1443 |
| 226 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M25 grade with minimum cement content of 330 kg /cum All works above plinth level upto floor V level DSR 5.33.2.2 |
| 227 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). DSR 16.69 |
| 228 | Providing and stacking of Nauclea cadamba (Kadam) of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge. DSR 7.60 |
| 229 | Providing and stacking of Nyctanthes arbor-tristis (Hasingar) of ht. 90-105 cm in Earthen pots of size 20 cm as per direction of the officer-in-charge. DSR 8.54 |
| 230 | Providing and stacking of Terminalia arjuna of height 150-165 cm. in big polybags of size 25 cm as per direction of the officer-in-charge. DSR 7.88 |
| 231 | Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. DSR 7.71 |
| 232 | Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. DSR 7.72 |
| 233 | Providing and stacking of Ficus panda of height 90-105 cm. with 10-12 branches and healthy foliage, well formed in cement pots of size 30 cm as per direction of the officer-in-charge.. DSR 8.28 |
| 234 | Providing and stacking of Ficus reginald well branched, bushy of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.. DSR 8.24 |
| 235 | Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushtyshape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.. DSR 6.12 |
| 236 | Providing and stacking of Tradescantia zebrina having in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. DSR 6.31 |
| 237 | Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size of Poly bags & as per direction of the officer-in-charge. DSR 6.30 |
| 238 | Providing and stacking of Asparagus sprengeri of height 30 cm to 45 cm, full of leafy branches in 15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge.. DSR 6.4 |
| 239 | Providing and stacking of Ophiopogon jaburan ( variegated ), full of variegated leaves in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge. DSR 6.21 |
| 240 | Providing and displaying of Croton Petra Bangalore variety having ht. 60 cm to 75 cm with 4 to 6 branches, well developed, fresh and healthy colorful leaves in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. DSR 3.38 |
| 241 | Supplying and stacking of good earth at site including royalty but including carriage 1km (earth measusred in stacks will be reduced by 20% for payment). DSR 2.2 |
| 242 | Supplying and stacking at site dump manure from approved source,including carriage up to 1 km (manure measured in stacks will be reduced by8% for payment) DSR 2.4.3 |
| 243 | Mixing earth and manure in specified proportion or as directed. DSR 2.9 |
| 244 | Spreading of mixed good earth and manure in specified proportions as above and in required thickness. DSR 2.8 |
| 245 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead 2.25 |
| 246 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) DSR 5.2.2 |
| 247 | Reinforced cement concrete work in lighter beam , including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) DSR 5.3 |
| 248 | Reinforced cement concrete work in footing (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 5.1.2 |
| 249 | Diluting and injecting chemical emulsion for PRE- CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion):Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% DSR 2.35.3.1 |
| 250 | M-150 brick work in 1:4 cement and Coarse sand mortar in superstructure including supply of all material, labour and tools and plants etc required for proper completion of work for wall thickness 12 cms & below 6.4.1 |
| 251 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws DSR 9.21.1 |
| 252 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Sal wood (DSR 9.1.2) |
| 253 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glasspanes (DSR 10.30.1) |
| 254 | Providing and fixing bright finished brass each butt each with necessary screws etc. complete 125x85x5.5mm(heavy type) (DSR 9.72.1) |
| 255 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm (DSR 9.74.1 |
| 256 | Providing and fixing bright finished brass door latch with necessary screws etc. complete. 300x16x5 mm(DSR 9.75.1 |
| 257 | Providing and fixing bright finished brass handles with screws etc. complete. 125 mm (DSR 9.81.1) |
| 258 | Providing and fixing bright finished brass hangging type floor door stoper with necessary screws etc.compelte. (DSR 9.82) |
| 259 | 12 mm cement plaster 1:3( 1 cement: 3 coarse sand) 41456 |
| 260 | Add for plaster drip course/groove in plastered surface or moulding to R.C.C. projections.. 5.3 |
| 261 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. DSR 13.21 |
| 262 | Cement concrete flooring 1:2:4(1 cement:2 coarse:sand:4 graded stone agregate) finished with a floating coat of neat cement including cement slurry, etc. but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate 40603 |
| 263 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacture's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work DSR 13.52.1 |
| 264 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and DSR 13.82.2 |
| 265 | French spirit polishing: Two or more coats on works including a coat of wood filler. (DSR 13.68.1) |
| 266 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid forseparately. For the purpose of measurement the DSR 22.6 |
| 267 | Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete. (DSR 12.20) |
| 268 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Medium shade pigment using 50% white cement 50% Grey cement PWD 11.20.2 |
| 269 | Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge.10 x 60 mm DSR 10.27.1 |
| 270 | Providing and fixing M.S. grills of requirement pattern in frames of windows etc. with M.S. flats, square or round bars etc.all complete Fixed to steel windows by welding(D.S.R.9.48.1) |
| 271 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacture's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work(D.S.R.13.52.1) |
| 272 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper DSR 1.12 |
| 273 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. Earth wire DSR 1.14.1 |
| 274 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire DSR 1.14.4 |
| 275 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required20 mm. DSR 1.21.1 |
| 276 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections DSR 1.31 |
| 277 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. DSR 1.32 |
| 278 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. DSR 1.26 |
| 279 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required 2 Pair DSR 1.18.2 |
| 280 | Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular switches in recess etc as required1 or 2 Module (75 mm x 75 mm) DSR 1.27.1 |
| 281 | Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc asTelephone Socket outlet DSR 1.24.6 |
| 282 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door, horizontal type DSR 2.4.1 |
| 283 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as requiredsingle pole DSR 2.10.1 |
| 284 | Supplying and fixing following rating, four pole, 415 V,isolator in the existing MCB DB complete with connections, testing and commissioning etc. as40 amps. DSR 2.13.1 |
| 285 | Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as DSR 2.19 |
| 286 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. DSR 5.4 |
| 287 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring DSR 5.9 |
| 288 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re- filling etc. as required. DSR 5.11 |
| 289 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm DSR 1.50.1 |
| 290 | Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. CAT- PWD 1413 |
| 291 | Supply and fixing of 12 Watt to 15 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing with extended heat sink, diffuser of Polycarbonate meterial and driver set complete in all respect. CAT- AAA PWD 1410 |
| 292 | Supply and fixing of recess/ Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in PWD 1410 |
| 293 | Supply and fixing of recess mounting round 15 to 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA PWD 1403 |
| 294 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fitting and fixtures completed including cutting and making good the walls and floors wherever required.White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type DSR 42736 |
| 295 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer DSR 17.7A |
| 296 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.32 mm dia (for wash basin) DSR 17.28.2.1 |
| 297 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.40 mm dia (for sink and urinal) DSR 17.28.2.2 |
| 298 | Providing & Fixing 600 X 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. DSR 17.31 |
| 299 | Providing & fixing viterous china toiletpaper holder. DSR 17.34.2 |
| 300 | Providing & fixing white vitreous china water less urinal of size 600 x 330 x 315 mm having antibacterial /germs free ceramic surface, fixed with cartridge having debris DSR 17.79 |
| 301 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finishedsmooth. DSR 8.10.2 |
| 302 | Providing and fixing of 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms DSR 17.73.2 |
| 303 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, DSR 17.71 |
| 304 | Providing and fixing PTMT grating of approved quality and colour. Circular type:125 mm nominal dia with 25 mm waste DSR 18.58.1.2 |
| 305 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work 110 mm O.D |
| 306 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work 160 mm O.D |
| 307 | Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size). Including cost of cutting holes & making good the walls etca) for 100mm dia pipe. DSR 17.37.1 |
| 308 | Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size). Including cost of cutting holes & making good the walls etcb) for 75mm dia pipe. DSR 17.37.2 |
| 309 | Providing & fixing upvc SWR bend confirming to IS -14735110mm dia DSR 17.60.2.1 |
| 310 | Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.a) 100mm DSR 17.38.1.2 |
| 311 | Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.b) 75mm DSR 17.38.2.2 |
| 312 | Providing and fixing centrifugaly cast iron single equal plain junction of required100x100x100mm DSR 17.44.1.2 |
| 313 | Providing and fixing centrifugaly cast iron single equal plain junction of required75x75x75mm DSR 17.44.2.2 |
| 314 | Providing and fixing cast iron terminal100 mm DSR 17.56.1.2 |
| 315 | Providing and fixing cast iron terminal75 mm DSR 17.56.2.2 |
| 316 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm DSR 12.41.2 |
| 317 | Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good walls etc.Internal work-Exposed on wall 15mm dia nominal bore DSR 43374 |
| 318 | Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good walls etc.Internal work-Exposed on wall 20mm dia nominal bore DSR 43375 |
| 319 | Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good walls etc.Internal work-Exposed on wall 25mm dia nominal bore DSR 43376 |
| 320 | Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good walls etc.Internal work-Exposed on wall 32mm dia nominal bore DSR 43377 |
| 321 | Painting GI pipes and fittings with SYNTHETIC enamel paint over a ready mixed priming coat, both of approved quality 15mm dia nominal bore DSR 18.38.1 |
| 322 | Painting GI pipes and fittings with SYNTHETIC enamel paint over a ready mixed priming coat, both of approved quality 20mm dia nominal bore DSR 18.38.2 |
| 323 | Painting GI pipes and fittings with SYNTHETIC enamel paint over a ready mixed priming coat, both of approved quality 25mm dia nominal bore DSR 18.38.3 |
| 324 | Painting GI pipes and fittings with SYNTHETIC enamel paint over a ready mixed priming coat, both of approved quality 32mm dia nominal bore DSR 18.38.4 |
| 325 | Concealed pipe including painting with anticorrosive bitumatic paint, cutting chases and making good the wall.(internal work)Exposed on walla) 15mm dia nominal outer dia pipes DSR 43405 |
| 326 | Concealed pipe including painting with anticorrosive bitumatic paint, cutting chases and making good the wall.(internal work)Exposed on walla) 20mm dia nominal outer dia pipes DSR 43406 |
| 327 | Providing & fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)25 mm nominal bore DSR 18.17.1 |
| 328 | Providing & fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)32 mm nominal bore DSR 18.17.2 |
| 329 | Providing and fixing ball valve (brass) of approved quality complete. (High or low pressure with plastic floats).25 mm nominal bore DSR 18.18.3 |
| 330 | Providing & fixing 15 mm nominal bore 45 cm long unplasticised PVC connection pipe with brass unions. DSR 18.21.2.1 |
| 331 | Providing & fixing 15 mm nominal bore CP brass bib cock of approved quality conforming to IS 8931. DSR 18.49.1 |
| 332 | Providing and fixing 15 mm nominal bore C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. DSR 18.50.1 |
| 333 | Providing & fixing 15 mm nominal bore C.P brass angle valve for basin mixer and geyser points of approved quality conforming to IS DSR 18.53.1 |
| 334 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fitting and base support for tank.750 litres capacity DSR 18.48 |
| 335 | Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soila) Pipes, cables etc. exceeding 80 mm dia.but not exceeding 300 mm dia DSR 2.10.1.2 Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail