| 1 | Item Name |
| 2 | Supply & Fixing of 11 Meter long Strel Tubular Pole SP-55. (410 SP 55) |
| 3 | Supply & Fixing of 11 KV XLPE insulated armoured AI. Cable of size 3Cx185 sq. mm |
| 4 | Supply & Fixing of 11 KV Polymer Pin Insulators (5KN), pin with N&B |
| 5 | Supply & Fixing of LT Unarmoured Aluminum XLPE Cable 1 Cx400 Sq.mm |
| 6 | Supply & Fixing of Galvanised channel 125x65mm with clamp & nut bolt. |
| 7 | Supply & Fixing of Galvanised channel 100x50mm with clamp & nut bolt. |
| 8 | Supply & Fixing of Galvanised Angle 65x65x6 mm with clamp & nut bolt. |
| 9 | Supply & Fixing of Galvanised Angle 50x50x5 mm with clamp & nut bolt. |
| 10 | Supply & Fixing of Outdoor type 11 KV SF6 type extensible and motorized 3 way smart Ring Main Unit (RMU) complete with One VCB ad two LBS, FPI & FRTU along with supply through 1 KVA auxilliary power transformer 11/0.230 KV as per Discom Specs along with other allied material like cable, ternination kits etc. to connect the same with system Rod Type Earthing complete with GI strip (2 nos) & foundation work |
| 11 | Suplly & Fixing of Outdoor type 11 KV SF6 type extensible and motorized 5 way smart ring Man unit (RMU) complet with three VCB and two LBS, FPI & FRTU along with along with supply through 1 KVA auxilliary power transformer 11/0.230 KV as per Discom Specs along with other allied material like cable, ternination kits etc. to connect the same with system Rod Type Earthing complete with GI strip (2 nos) & foundation work |
| 12 | Supply & Fixing of Fing of Outdoor type LT Disribution Boards with a rupturing capacity of 50KA at 415V or as called for individual items (CPRI Approved manufacturer), openable in front and back suitable for 3 plase, 4 wire, 50Hz AC Supply and and ambient temperature of 45 deg. C. The Cubicle should be weather proof, dust proof, vermin Proof and enclosure protection shall be IP-55 as per IS 2147-1962 and IS: 8623. THE panels/switches boards shall be fabricated out of 14-SWG CRCA sheet steel and provided with 16 SWG hinged doors in. MAIN K LT PANEL AT SUB STATION-630 KVA (Type-A-2) Incomer-1 No. 1250 Amp. TPN ACB with Inbuilt MPR Release with On/off Indicating Light Metering on Incomer-1 SEt of Ditital Ammeter with ASS -1 Set of Digital Voltmeter with VSS -1 Set of LED type Phase Indicating Light (22.5mm.) with Control MCBs Outgoing-4 Set of 400 Amp. TPN MCCB with Spreader & Extended handle -2 Set of 250 Amp. TPN MCCB & 2 Set 100 Amp TPN MCCB with Spreader & Extended handle |
| 13 | Supply & Fixing of Outdoor type LT Distibution Boards with a rupturing capacity of 50KA at 415V or as called for individual items (CPRI Approved manufacturer), openable in front and back suitable for 3 plase, 4 wire, 50Hz AC supply and an ambient temperature of 45 deg. C. The Cubicle should should be weather proof, dust proof, vermin Proof and enclosure protection shall be IP-55 as per IS 2147-1962 and IS: 8623. The panels/switches boards shall be fabricated out of 14-SWG CRCA sheet steel and provided with 16 SWG hinged doors inc. MAIN LT PANEL AT SUB STATION-400 LVA (TypeA-3) Incomer-1 SEt of 800 Amp. TPN MCCB with Spreader & Extended handle Metering on Incomer-1 Set of Digital Ammeter with ASS 1- Set of Digital Voltmeter with VSS -1 Set of LED type Phase Indicating Light (22.5mm.)with Contorl MCBs Outgoing -4 Set of 250 Amp. TPN MCCB with Spreader & Extended handle -2 Set of 100 Amp. TPN MCCB with Spreader & Extended handle. |
| 14 | Supply & Fixing of 9KV 5KA Distribution Class LA. (3Nos-1 Set) |
| 15 | Supply & Fixing of G.I. Barbed Wire. |
| 16 | Supply & Fixing of 110 mm dia. HDPE pipe by Horizontal drilling by HDD method as per site condition, (PE80 PN 6 as per IS: 4984/2026) |
| 17 | Supply & Fixing of G.I. pipe 100 mm dia with clamps, Nut and Bolt. (Medium Duty Class A ) |
| 18 | Supply & Fixing of Heart Shrinkable Termination Ki Outdoor for 11 KV 3x185 sq. |
| 19 | Supply & Fixing of Heat Shrinkable Termination Kit S/T for 11 KV 3x185 sq. mm XLPE Cable |
| 20 | Supply & Fixing of Paniting of Alluminum paint |
| 21 | Supply & Fixing of Paniting of Red Oxide Paint |
| 22 | Supply & Fixing of Al. crimping lugs 400 sq.mm. |
| 23 | Supply & Fixing of Al. crimping lugs 50 sq. mm. |
| 24 | Supply & Fixing of 11 KV MS Danger Board (250x200mm) with clamp and Nuts & Bolts |
| 25 | Supply & Fixing of GI Holding clamps for top channel/Base Channele/AB Switch & fuse set etc. with bolts & nuts. |
| 26 | Supply & Fixing of Double Compression Weatherproof Nickel Plated Brass Cable Glands for Armoured Cable gland of suitable size along with Lugs (4 nos Per Glands) and all accessories |
| 27 | Supply & Fixing of LT Unarmoured Aluminium XLPE insulated Cable of size 1Cx50 Sq. mm |
| 28 | Supply & Fixing of 3 phase 11 KV TPMO with polymer insulator (1 Set=3 Nos) |
| 29 | Supply & Fixing of 3 Phase 11 KV Fuse set (Drop out) with clamps. (1 Set=3 Nos) |
| 30 | Loading Unloading and carriageof 3x185sqmm XLPE Cable from Local central store to site |
| 31 | Loading Unloading and carriage of All Other material from Local central store to site |
| 32 | Concreting of supports with Grounting of 0.44 cum (1:2:4,1-cement, 2-coarse sand, 4-concerate of 20mm size) of 11 mtr STP Pole of depth 1-8 meter with 300 mm Muffing. As per TS. |
| 33 | Laying of Double Circuit 3x185 Sq. mm 11 KV XLPE insulated cable underground in HDPE Pipe by digging of trench or by HDD Methode as found |
| 34 | Hoisting of cable on double pole with the help of cable clamp with N&B of suitable |
| 35 | Plinth & foundation of Outdoor type LT Disribution Boards for 630KVA Transformer |
| 36 | Plinth & foundation of Outdoor type LT Disribution Boardsfor 400 KVA Transormer |
| 37 | Supply & Erection of Chemical pipe Earthing (80 mm dia,3 M long) for T/F Neutral and Body with GI Flat earthing strp my making delta earthing as per State Norms. ( B Type) |
| 38 | Fixing of fitting on newly erected pole for making double pole structure for TF |
| 39 | Dismantling of Old Existing ransformer and shifing to new DP then making connection in all respect. |
| 40 | Construction of elevated T/F plinth and foundation on 2x(9INCH*9INCH) RCC Piller upto the height of 9.8 fit from the ground level. The size of Top T/F plinth will be 1.5 Mtrx1.8Mtr having the sturcute of GI channel of size 125x65x6mm-2500mm for 11KV DO fuse unit including cost of all civil material as TS. |
| 41 | Supply & Erection of 9 KV 5 kA Distribution Class LA(3nos-1 set) |
| 42 | Undergrounding of LT infra in Commissionary Office Premises under the area of UEDD Varanasi |
| 43 | Supply of 3 1/2 Core, 240 sqmm, Armoured AI conductor XLPE insulated 1.1 kV grade armoured Power cable as per Technical specification. |
| 44 | Supply of 3 1/2 Core, 150 sqmm, Armoured AI conductor XLPE insulated 1.1 kV grade armoured Power cable as per Technical specification. |
| 45 | Supply of 3 1/2 Core 95 Sqmm Armoured AI conductor XLPE insulated 1.1 kV grade armoured power cable as per Technical specification. |
| 46 | Supply of 3 1/2 core, 25 sqmm Armoured AI conductor XLPE insulated 1.1 kV grade armoured power cable as per Technical specification. |
| 47 | Supply of GI earthing rod of 20x2500mm (GI solid Rod) |
| 48 | Supply of HDPE Pipe 160 mm Suiitable for 3.5 Cx240 sqmm cable by Open Trench. |
| 49 | Supply of HDPE pipe 110 mm Suitable for 3.5 Cx150 sqmm Cable by Trench. |
| 50 | Supply of HDPE Pipe 50 mm Suitable for 3.5 Cx 25 sqmm cable by Open |
| 51 | Supply & Erection Cable end termination using total double compression brass glands and crimping tpe Aluminium Thimbles (4nos per glands) for Suitable size. |
| 52 | Supply & Erction of outdoor type feeder pillar panel to be made of 2 mm CRCA Sheet and covers will be 1.6 mm CRCA sheet duly powder coated paint with 400 amps AI. Busbar. (Type-B1) Incomer-250 Amp. TPN MCCB-1 No. Outgoing-100 Amp. TPN MCCB-2 Nos. The Cubicle should be weather proof, dust proof, vermin Proof and enclosure protection shall be IP-55 (suitable for outdoor applications) as per IS |
| 53 | Supply & Erection of 3-ph 415 V, Distribution service Piller for LT, 100 Amp MCCB Incoming, 4 nos 32 Amp with Sp MCB, 12 Nos 16 Amp with SP MCB Rating Feeder Type CRCA Distribution Service Piller suitable for Outdoor Installation. At CRCA, as per techincal specification & drawing. |
| 54 | Loading Unloading and carriage of LT XLPE Cable from Local central store to site |
| 55 | Loading Unloading and carriage of All Other material from Local central store to site |
| 56 | Ditting of trench for laying of HDPE Pipe for Cable laying and making of trench for one nos cable with brick on both side, sand filling into the trench and finally trench will be covered with stone after laying of cable into the trench including providing and fixing cable route markert. |
| 57 | Laying of XLPE insulated (3.5x240sqmm, 3.5x150sqmm, 3.5x95 sqmm & 3.5x25 sqmm) cable underground in trenches inside HDPE pipe |
| 58 | Supply & Erection of Chemical pipe earthing of Outdoor type Distribution feeder pillar Box my making delta earthing with gi stripe of size 25x5mm (B Type) (80mm dia, 3 M log) |
| 59 | Construction of Plinth for Outdoor type Distribution feeder ipllar Box (B/c 1 Type) |
| 60 | Erection of GI earthing rod of 20x2500 mm (GI soild Rod). And 6 SWG GI wire etc. together with fixing arrangement as per TS. (C-Type) |
| 61 | Connection of all LT service cable and shifting of meter/reseal of meter |
| 62 | Road Cutting and Reparing Up to Depth 1 Mtr and 0.75 mtr width including GSB grade 2, Wmm, Prime cote, BM Tack cote and BC. Please Enable Macros to View BoQ information |