| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group C |
| 3 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2-way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 4 | Rewiring for light pt. / fan pt. / exhaust fan pt. / call bell pt. with 1.5 sq mm FRLS PVC insulated copper conductor single core cable and 1.5 sq mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit i/c dismantling etc as reqd. |
| 5 | Group C |
| 6 | Supplying & Drawing of following size of FRLS PVC insulated copper conductor, single core cable in the existing surface / recess steel / PVC conduit as reqd. |
| 7 | 3 x 1.5 sq mm |
| 8 | 3 x 4 sq mm |
| 9 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 10 | 20 mm |
| 11 | 25 mm |
| 12 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC Medium conduit as required |
| 13 | 3 x 1.5 sq mm |
| 14 | 3 x 4 sq mm |
| 15 | 6 x 4 sq mm |
| 16 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 17 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 18 | 5/6 amps switch |
| 19 | 2 way 5/6 amps switch |
| 20 | 15/16 amps switch |
| 21 | 3 pin 5/6 amp socket outlet |
| 22 | 6 pin 15/16 amp socket outlet |
| 23 | Stepped type electronic fan regulator( 2 module) |
| 24 | Blanking plate (modular) |
| 25 | Supplying and fixing following size modular, GI box alongwith modular base & cover plate for modular switches in recess etc as reqd. |
| 26 | 6 Module (200 mm x 75 mm) |
| 27 | 8 Module (125 mm x 125 mm) |
| 28 | 12 module (200mm x150mm) |
| 29 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface / recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted i/c earthing etc complete as reqd. (But without MCB/RCCB/Isolator) |
| 30 | 12 way, Double door |
| 31 | S & F following rating / series 240 volts miniature circuit breaker/Isolator suitable for lighting and other loads / inductive load of following poles in the existing MCB DBcomplete with connections, testing and commissioning etc. as reqd. |
| 32 | 5 to 32 amp Single Pole 'C' Series |
| 33 | 40 Amp Double pole C- Series(Isolator) |
| 34 | Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes incubicle panel, making connections, etc. as required. |
| 35 | 125 Amp, 16 KA, TPMCCB |
| 36 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing alongwith existing surface/recess conduit/submain wiring/ cable as required. |
| 37 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC Medium conduit as required |
| 38 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 39 | Supply, Installation, Testing and Commissioning of 1200 mm sweep Energy Saving 5 Star AC ceiling fan complete with all accessories i/c wiring the down rod with 1.5 sqmm FRLS PVC insulated copper cond. cableand earthing etc as required. |
| 40 | Supplying and fixing 300 mm heavy duty exhaust fan with louver in the existing opening making the hole to suit size of above fan making good the gamageconnection testing etc complete as reqd |
| 41 | SITC of LED batten fitting minimum 2000 lumens, system efficacy 100 Lumens/watt, LED Batten with colour temperature 3000-6500K complete with connection testing etc. as required. |
| 42 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die castaluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P.F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K/6500°K(As per ANSI Bin),SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mmFRLS/HFFR, PVC insulated copper conductor single corecable and earthing etc. as required with Minimum 5 year OEM warranty. and the fixture shall be fixed on the walls with painted MS angle frame with saddle and the fixture shall be provided with toughened glass covering in addition to the lense of the LED with System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCTshall be as approved by Engineer-in-Charge as per requirement .(Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).90Watt |
| 43 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke andsalt as required. |
| 44 | SITC of 1 HP monoblock centrigugal clear water pump (25x25 mm) fitted with motor suitable to operate on 230 V 50 HZ AC supply ,the minimum doscharge shall be 50 Litr/min at 6 mtr Head ,F class copper winding ,carbon steel pump[ shaft ,cast iron impeller ,High quality mechanical seal ,high grade pump castings (FG-200 or equivalent ) wih iron cage i/c complete as required. |
| 45 | SITC of floor/wall mounted control LT feeder pillar cubicle type double door of suitable size duly compartmentalized and with general arrangement made out of 2 MM thick MS CRCA sheet having hinged gasketted cover and screwed knobs with double locking arrangement i/c connections ,inter connections with suitable sixe of FRLS PVC insulated copper conductor using thimbles wherever required as per technical specifications attached i/c supply and fixing of following accessories complete as required- a) 125 A, 36 KA, 415 Volt, FP MCCB - 1 No.(INCOMER)b) 63 A, 10 KA, 415 Volt, FPMCCB - 1 No.(outgoing)c) 32 A DPMCB 10KA -10 Nos d) 200 amp, 4 strip aluminium bus bar - 1 sete) 16 A SPMCB 10 KA . - 05 Nos .f) Volt meter (0-500V) 96 Sq.mm with selector switch – 1 Setg) Ammeter (0-100V) 96 Sq.mm with selector switch – 1 Set. h) Gland plate with gland – 1 seti) Danger Notice plate – 1 No.j) 6 pin 15 Amp switch / socket outlet – 1 Set k) Lighting inside the feeder pillar l) Indication lamp (RYB) LED - 01 Set. m) Outgoing circuit -16 Amp,10KA SP MCB C series -05 sets,32 amp 10 ka DPMCCB C curve - 5 set.o) DOL starter with relay range of 6-10 A suitable for 1 HP single phase motor- 1 set Note: Foundation shall be made as per site requirement for which nothing extra shall be paid. |
| 46 | Fabricating, supplying and fixing of angle iron steel structure frame work fabricated out of 40 mm x 40 mm x 5 mm angle iron and providing and fixing wire mesh of 8 SWG of size 1.5 m length x 1.5 m height x 1 m depth and shall be fixed and supported with 40 mm x 5 mm M.S. flats and the frame is to be grouted with M.S. angle legs not less than 30 Cm in cement concrete 1:2:4 (1 cement :2 course sands and 3 stone aggregate in foundation, painted two armour coat of red wide primer and two coat of synthetic enamel paint and providing leaf door with 12 nos. hinges of size 75x60x3 mm in front and rear with two nos. sliding door and 2 nos. of godown lock for locking arrangement complete etc. required. Please Enable Macros to View BoQ information |