| Sl. No. | Item Description |
| 1 | BOQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CHIEF ENGINEER (AF) SHILLONG ZONE, SHILLONG. Name of Work: CONSTRUCTION OF DEFICIENT MARRIED ACCOMODATION FOR AIRMEN AT HQ EAC(U) AF UNDER GE(I) AF SHILLONG Contract No: CE(AF)SZ/SHL/ OF 2025-2026 File No: 88993/SHL/E8 Bidder Name : PRICE SCHEDULE : BOQ(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SL No ITEM DESCRIPTION Item Code / Make QTY UNIT ESTIAMTED RATE Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE IN FIGURES TO BE ENTERED BY THE BIDDER RS. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT IN WORDS Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | Sch 'A' Part-I (BUILDING WORK)Details of prepriced Schedule is given in tender documents |
| 3 | Total amount of Such 'A' Part-II (SITE CLEARENCE, SITE DEVELOPMENT AND EARTH WORK)Details of prepriced Schedule is given in tender documents |
| 4 | Total amount of Such 'A' Part-III (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents |
| 5 | Total amount of Such 'A' Part-IV (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents |
| 6 | Total amount of Such 'A' Part-V (ROAD/PATH/CULVERT) Details of prepriced Schedule is given in tender documents |
| 7 | Total amount of Such 'A' Part-VI (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents |
| 8 | Total amount of Such 'A' Part-VII (SEWAGE DISPOSAL)Details of prepriced Schedule is given in tender documents |
| 9 | Total amount of Such 'A' Part-VIII (FENCING) Details of prepriced Schedule is given in tender documents |
| 10 | Total amount of Such 'A' Part-IX (RETAINING WALL) Details of prepriced Schedule is given in tender documents |
| 11 | Total amount of Such 'A' Part-X (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents |
| 12 | Total amount of Such 'A' Part-XI (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents |
| 13 | Total amount of Such 'A' Part-XII (FIRE FIGHTING )Details of prepriced Schedule is given in tender documents |
| 14 | Total amount of Such 'A' Part-XIII (LIGHTENING PROTECTION)Details of prepriced Schedule is given in tender documents |
| 15 | Total amount of Such 'A' Part-XIV (FIRE POINT 02 NOS.)Details of prepriced Schedule is given in tender documents |
| 16 | Total amount of Such 'A' Part-XV (GARBAGE BIN)Details of prepriced Schedule is given in tender documents |
| 17 | Total amount of Such 'A' Part-XVI (DEMOLITION/DISMANTLING/TAKING DOWN)Details of prepriced Schedule is given in tender documents |
| 18 | SCHEDULE \\"A\\" PART -XVII (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under Col.' F ' signifies this fact only. |
| 19 | INTERNAL ELECTRIFICATIONS&F modular TV socket single module, polycarbonate type complete with box all as specified & directed. |
| 20 | S&F LED lamp 10 watt complete all as specified & directed. |
| 21 | Supply and fixing LED light fitting 2 feet, 1x10 watt, 220 V, AC decoratiive type with driver including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all specified and directed. |
| 22 | INTERNAL WATER SUPPLYS&F 20mmbore sink mixer with regular spout for mixing hot & cold water fixed complete all as specified and directed. |
| 23 | S&F central hole basin mixer without pop up waste system with 450mm long braidede hose complete all as specified and directed. |
| 24 | Supply and fix ABS overhead shower round 100mm with brass arm 225mm with flange complete all as specified and directed. |
| 25 | S&F wall mixer 3-in-1 system with provision for bath hand shower and over head shower complete with legs and wall flange ( without hand shower and over head shower) complete all as specified and directed. |
| 26 | S&F ABS hand shower with SS shower tube 1.5m length complete all as specified and directed. |
| 27 | S & F 20 mm dia angle cock with wall flange concealed type screwed down for iron pipe or for unions complete all as specified and directed. |
| 28 | S & F 20 mm two way angle cock with wall flange concealed type screwed down for iron pipe or for unions complete all as specified and directed |
| 29 | SEWAGE DISPOSALM&L for construction of RCC Septic tank conventional designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and RoofSlab including beams etc with Vent shaft , manhole openings with cover connection etc. with effective depth of 1.5 mtr and overall depth of 3.0 mtr complete for 150 users including RFR, removal complete all as directed and shown in drawings. |
| 30 | M&L for construction of soakage wells ,excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.6 mtr dia x 3.0 mtr effective depth complete all as directed and shown in drawings. |
| 31 | EXTERNAL WATER SUPPLYSupply and laying ductile iron PIPE 100mm bore SPIGT SOCKET JOINT type including special class , class K-9, for pumpimg line/ gravity line / coloumn pipe for suction complete for the following sizes including jointing materials all as specified and direceted |
| 32 | M & L for valvepit & Construction of brick masonary valve pit size 90x 90x 90 cm (internal dimension) one brick thick wall in cm 1:4 and 100 mm thick PCC 1:4:8 in foundation and 15 mm thick MS sheet/plate welded with 40x40x6 mm angle iron frame fixed or top of valve pit by means of hold fast 150mm long, embedded in PCC 1:2:4 type B1, bricks of size 230x110x75 including two coat of anticorrsive paint over a coat of red oxide primer and necessary earth work in soft/ loose soil complete all as specified and as directed. |
| 33 | Labour only for cutting, screwing without taking down existing galvanised steel water tubing of size 150/100mm bore, connected all items for addition/alteration complete all as specified and directed. |
| 34 | M&L for ductile iron pipes fittings both flanged & socket type i.e. socket,bend, nipple,Y & tail piece flange etc and incl all jointing materials (rubber joint for tyton joint) of pipes complete all as specified and directed |
| 35 | EXTERNAL ELECTRIFICATIONSupply, install, testing and commissioning of outdoor type transformer step down, copper wounded having primary side for HT Three Phase 11 KV & secondary for 3 phase 433 Volts, 4 wire, 50 Hz of capacity 160 KVA as per IS-1180-2014 Part-I or as per latest IS amendment Level-II with and including the following specification:-(i) No load voltage ratio-11KV/ 0.433 KV, (ii) Nos of phase-Three (iii) Type of cooling- ONAN (iv) Frequency- 50 Hz (v) Vector group-DYN 11 (vi) Two earthing terminals for body earthing and two additional for neutral (vii) Oil level gauge indicating oil level with minimum and maximum indication (viii) Lifting lugs rollers and MS terminal box on both HT and LT side (ix) Rating and terminal marking plates (x) Dehydrating breathing device which would not permit ingress of moisture, rain water and insects (xi) Drain-cum-sampling valve preferably steel with plug (xii) Off load tap changar (+5% to -10% in steps of 2.5% with 7 position) (xiii) Oil filling hole with cover (transformer wih conservator) (xiv) Connection-Delta/Star (xv) Temperature rise in oil-40 deg celcius (xvi) Temperature rise in windings- 45 deg Celcius (xvii) Material winding-Copper wound (xviii) High voltage/low voltage with cable termination box (xix) Service-Outoor type (xx) Neutral- Internally conneted with earthing lead and bush (xxi) First filling of new dehydrated transformer oil upto recommended level.Note:- (i) Contractor shall submit the general arrangement drawing and details for approval to GE (I) AF before placing order. (ii) Factory test carried out by testing officer nominated by AO.(iii) Pre commissioning test shall be carried out by SEI/EI. (iv) Plinth foundation for the transformer as recommended by manufacture OEM or as directed by Engr-in-Charge is deemed to be include in quoted rate including necessary earth work. |
| 36 | M&L for horizontal Boring for passing GI protection pipe up to 100 mm bore (dia), under road / foot path, not exc. 10.00 metre in a single length, complete all as specified and as directed. |
| 37 | M&L for weather proof IP-66 cable junction box of size 200x 160x098 mm for outdoor installations with terminals set of 10 Sqmm 4 Pole-01 mounting bracket and polyamide cable gland with lock nut (Type-KF PV-0500) and manking provision and including of an MCB SPN of suitable size including internal connetion by proper sizes copper/aluminium lugs/thimble all as specified and directed. |
| 38 | Suppy/install, testing, commissioning LT feeder pillar box outdoor type vermin /weather proof of overall dimension as suitable size required at site (leg of the feeder pillar not less than 300 mm in length) made out of 3.0 mm thick CRCA sheet supported on structural frame of angle iron (50x 50x 6)mm incl canopy type roof 10cm extended in all sides and two part hinged door in front side with locking & gasket arrangement (incl one Pad lock of 7 lever with 03 keys) duly two coats of powder coated paint internally/externally on the surface incl provn of 04 Nos 500Amps Aluminium Bus Bar strip (covered with PVC insulated sleeves) fixed on PVC insulators and internal connections with required rating of Aluminium cable and terminals, grouting on PCC foundation as per site requirement as directed by Engr-in Charge. The FP box consisting the following accessories:- Main Incoming : (i) MCCB 320 amp 4 Pole, 35 KA-1 No Main Outgoing : (i) MCCB 200 Amp 4 Pole-35 KA-02 (1x No working + 1 No s/by) (ii) MCCB 100 Amp 4 Pole-25 KA-02(1x No working + 1 No s/by) (iii) MCCB 63 Amp 4 Pole-25 KA-01 (iv) Phase indication lamp RYB -03 Nos (v) Ammeter-03 No (vi) Volt meter-01 No (vii) Digital multimeter |
| 39 | Suppy/install, testing, commissioning LT feeder pillar box outdoor type vermin /weather proof of overall dimension as suitable size required at site (leg of the feeder pillar not less than 300 mm in length) made out of 3.0 mm thick CRCA sheet supported on structural frame of angle iron (50x 50x 6)mm incl canopy type roof 10cm extended in all sides and two part hinged door in front side with locking & gasket arrangement (incl one Pad lock of 7 lever with 03 keys) duly two coats of powder coated paint internally/externally on the surface incl provn of 04 Nos 300Amps Aluminium Bus Bar strip (covered with PVC insulated sleeves) fixed on PVC insulators and internal connections with required rating of Aluminium cable and terminals, grouting on PCC foundation as per site requirement as directed by Engr-in Charge. The FP box consisting the following accessories:- Main Incoming : MCCB 200 amp 4 Pole, 35 KA-1 No Main Outgoing : (i) MCB TPN 40 Amp -09 (ii) Phase indication lamp RYB -03 Nos (iii) Ammeter-03 No (iv) Volt meter-01 No (v) Digital Multimeter |
| 40 | Suppy/install, testing, commissioning LT feeder pillar box outdoor type vermin /weather proof of overall dimension as suitable size required at site (leg of the feeder pillar not less than 300 mm in length) made out of 3.0 mm thick CRCA sheet supported on structural frame of angle iron (50x 50x 6)mm incl canopy type roof 10cm extended in all sides and two part hinged door in front side with locking & gasket arrangement (incl one Pad lock of 7 lever with 03 keys) duly two coats of powder coated paint internally/externally on the surface incl provn of 04 Nos 200Amps Aluminium Bus Bar strip suitable size (covered with PVC insulated sleeves) fixed on PVC insulators and internal connections with required rating of Aluminium cable and terminals, grouting on PCC foundation as per site requirement as directed by Engr-in Charge. The FP box consisting the following accessories:- Main Incoming : MCCB 100 amp 4 Pole, 35 KA-1 No Main Outgoing : (i) MCB 32 Amps TPN-05 (3x Working + 2 S/By) (ii) Phase indication lamp RYB -03 Nos (iii) Ammeter-03 No (iv) Volt meter-01 No |
| 41 | M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6mm thick elecrode and 32mm x 6mm galvanised iron strip as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI strip 32mm x 6mm as earth lead by means of bolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 40mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed.NOTE : (i) The earthing pit should be provided with proper earth pit and pit cover. Pit cover should be painted with synthetic enamel paint of approved colour and pit number to be marked on pit cover as per colour code followed in AF Station.(ii) If the desired earth registance is not achive during testing as per IS the complete earthing shall be carried out by the contractor at his own cost and no extra claim shall be admissable. |
| 42 | M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6mm thick elecrode and 4mm galvanised iron wire as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI wire 4mm as earth lead by means of bolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 20mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed.NOTE : (i) The earthing pit should be provided with proper earth pit and pit cover. Pit cover should be painted with synthetic enamel paint of approved colour and pit number to be marked on pit cover as per colour code followed in AF Station.(ii) If the desired earth registance is not achive during testing as per IS the complete earthing shall be carried out by the contractor at his own cost and no extra claim shall be admissable. |
| 43 | FIRE FIGHTINGSupply and fix Cast Iron Air Release Valves with double air Outlets, conforming to IS 14845 of size 100 mm dia bore and fixing up in Cast Iron Water supply mains of size 100 mm dia complete all as specified and directed. |
| 44 | Supply, instalation, testing and commissioning of RTU logic development for central monitoring through wireless communication at Master control panel including wireless modem suitable for GSM base communication system to be mounted in RTU enclosure and shall be installed in buildings(it should also be used as a GSM based autodialler, to be installed with the main control panel including having minimum 10 mos mobile connection facility and at least memeory for voice recording of minimum minutes dataincluding provision of GSM sim card (including rental and SMS charges for period of one year) in port including TCP/IP card RS232 interfaces for connecting with Graphic Monitor Centre and Defining tool.Modify address of communication card including necessary programming as per site requirement complete all as speicifed and directed. |
| 45 | Supply installation commissioning and testing of first aid fire hose reel wall mounting swinging type complete with drum, bracket, 20 mm dia, 30 m long high pressure hose reel tubing with gun metal shut off nozzel confirming to IS 8090:1976. The hose reel shall be as per IS 884:1985 complete all as specified and directed. |
| 46 | Supply only of fire extinguisher, ISI Marked, Dry Powder ( ABC MAP 90) 6 KG capacity consisting of welded cylinder, fitted with pressure gauge with internal discharge tube, discharge nozzle suspension bracket, confirming to IS: 16018 complete all as specified and directed. |
| 47 | Supply only of fire extinguisher, ISI Marked,,Light weight, squeeze grip type CO2 type fire extinguisher, 4.5 KG capacity confirming to IS: 15683:2006( old IS: 2878) made from seamless cylinder confirming to IS: 7285 duly approved by chief controller of explosives, Nagpur fitted with ISI Marked Controlled Valve confirming to IS: 3224, high pressure, 1 mtr long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket, suitable for operating between 30 degree centigrade to +55 degree centigrade, Fire Rating Class-13B complete all as specified and directed. |
| 48 | Supply only of Fire extinguisher mechanical foam extinguisher as per IS: 15683, 9 ltr capacity complete all as specified and directed. |
| 49 | S&F of glow in dark sign board PVC wall mounted of size 300x100 mm for escape lighting entry/exit signage, no smoking zone complete all as specified and directed. |
| 50 | LIFTSupply, installation, testing and commissioning of lifts suitable to carry 13 passenger ( 884 Kg) at rated speed of 1.5 M/S to serve upto 7th floors (S+6 Floors) , electrically operated micro processror based VVVF drive system and micro processor based simplex selective collective controll with / with out attendent complete with power driven automatic , 3phase AC 415Volts , 50Hz power supply and having SS lift cabin with moon rock finish of dimension 1600 x 1400x 900mm power operated centre opening SS sliding door with moon Rock finish (Two panel enclosure ), ceiling LED light , PVC floor , SS round handle rail in rear side , cross flow fan, 7/7 stop/ opening with floor display charted (at each entrance position) . Car operating panel wich include SS car operating face plate with hair line finish ovel type button , orange square dot matrix scrolling display. Landing indicator include JLLP01 type landing operating panel, OSDM- V type landing display on wall, SS space plate ,material with hair line finish. Call register signal and SS Brallie button having safety feature like over speed governor, door protection, counter weight screen, over load indicator , fire man switch, automatic rescue device , battery operated emergency alarem light and two way intercom with press and speak in car operating panel complete all as specified and directed. |
| 51 | Supply, installation, testing and commissioning lifts suitable to carry 8 passenger ( 544 Kg) at rated speed of 1.5 M/S to serve upto 7th floors (S+6 Floors) , electrically operated micro processror based VVVF drive system and micro processor based simplex selective collective controll with / with out attendent complete with power driven automatic , 3phase AC 415Volts , 50Hz power supply and having SS lift cabin with moon rock finish of dimension 1300 x 1100x 800mm power operated centre opening SS sliding door with moon Rock finish (Two panel enclosure ), ceiling LED light , PVC floor , SS round handle rail in rear side , cross flow fan, 7/7 stop/ opening with floor display charted (at each entrance position) . Car operating panel wich include SS car operating face plate with hair line finish ovel type button , orange square dot matrix scrolling display. Landing indicator include JLLP01 type landing operating panel, OSDM- V type landing display on wall, SS space plate ,material with hair line finish. Call register signal and SS Brallie button having safety feature like over speed governor, door protection, counter weight screen, over load indicator , fire man switch, automatic rescue device , battery operated emergency alarem light and two way intercom with press and speak in car operating panel complete all as specified and directed. |
| 52 | DG SETSupply ,installation, testing & commissioning of silent/containerized diesel engine driven generating set of 58.5KVA capacity approved by CPCB (Central Pollution Control Board) norms IV + for Diesel Generator (DG) sets primarily focus on noise and emission control AC ,415 volts, 50 cycles per second, 3 phase, 4 wire supply with power factor 0.8, 1500 RPM diesel engine mounted on common base plate, anti vibration rubber mounting pad (AVM Pads \\"B\\" series) having AMF Panel with by pass arrangement (change over switch) complete in all respect with and including accessories and components as specified below including S&F sound proof accoustic enclosure for 58.5KVA Gen sets ECO friendly with CPCB norms and as per Ministery of Enviroment, forests notification 17 May 2002 complete including emergency stop button illumination inside canopy, Temprature sensor for high temp safety, exhaust fan etc complete as per IS 4722.(a) DIESEL DRIVEN ENGINE (PRIMEMOVER) :- Multi cylinder, verticla 4 stroke cycle, suitable for 58.5 KVA alternator, water cooled conforming to ISO : 3046/BS 5514 rated for continuous running diesel engine suitable to develop matching BHP at 1500 RPM as per latest ISS/BSS, capable of taking 10 % over load for any one hour in any 12 hour running, completewith and including following accessories:- |
| 53 | i) Fuel filterii) Governeriii) Complete battery set with lead & lugs as reccommended by manufactureriv) Lubricant oil coolerv) Lubricant oil pumpvi) Lubricant oil filtervii) Digital oil pressure gaugevii) Digital Oil pressure gaugeviii) Any other parts as prescribed by manufacturer for making it functionalix) Battery charging alternator of suitable capacityx) Dry type air filterxi) MS Channel fabricated frame rigidly welded suitable for receiving the diesel engine and alternator and anti vibration pads.xii) Coupling Guardxiii) Exhaust pipe fully extended to exhaust gases outside the the generating room including silencer and necessary insulation laggig with minimum 12mm dia asbestos ropexiv) Fuel tank of sheet steel and of capacity for 12 hours running on full load with inlet and outlet connection, filling cap, drain valve, air vent with calibrated scale on outer surface, floor mounted with suitable angle iron supports.xv) Digital type RPM meter with hour meter.xvi) Self starter of suitable size.xvii) Turbo charger |
| 54 | xix) Fuel pumpxx) Digital type coolent temp gaugexxi) Self starter with auto electric starter accessories.xxii) Engine safety low lubricant oil pressure and high coolant temprature.xxiii) Operating manualxxiv) Test certificates.(b) ALTERNATOR:- 58.5 KVA at 0.8 PF self excited, self regulated with fast response thyristor type, 3 phase, 50 Hz, 415 Volts, 1500 RPM, 4 wire alternator, screen protected drip proof free from commutation proble, continuous rating conforming to ISO : 3046/BS : 5514 complete with automatic voltage regulator out put voltage regulated between +_ 1% of set volts from No load to full Load with following accessories:-(i) Volt meter digital type (0-500 Volts) with selector switch-01 Set(ii) Ammeter digital type (0-400) amps with CT's & selector switch-01 Set(iii) Frequency meter digital type-01 No(iv) Indicating lamp LED based with toggle switches-01 set of three(v) Digital type KWH meter three phase-01 No(vi) Digital type PF meter three phase-01 No(vii) Safety alarm against high water temrature and hub oil pressure.(viii) Test of Gen set as specified in PS(ix) Class 'H' insulation limit to temperature rise of class H(c) Foundation complete as per manufacturer's design with anti-vibration pads including necessary excavation & earth work in soft/loose soil, sand cushioning, grouting in foundation etc |
| 55 | (d) ACOUSTIC ENCLOSURE: Supply & install of Acoustic Enclosure as per following:- i) Fabricated out of CRCA sheet of suitable thickness as per manufacturer design. Polyster based powder coated internaly and externaly with lockable type door handle. All nuts and handles shall be zinc coated.ii) The doors are gasketed with EPDM gaskets.iii) Sound proofing with high quality rock wool/mineral wool confirming to IS 8183 of 50 mm thickness and density at 96 Kg/M3 covered with fibre glass cloth and perforated powder coats sheet specialy designed allenuators (Sound controller) at air entry and exit of the container noice level shall be not exceed 75 Db at 1 meter distance as per CPCB normiv) Adequate ventilation to meet air requirement for combustion and heat removal with provn of a blower.v) Emergency stop push button out side the container.vi) Provn of light inside the canopy providing of FTL fitting 1x20 watt with wiring and control switch.vii) 12 V dry batteries with connecting lead and terminals.(e) CONTROL PANEL :- RAL 9003 white powder coated control panel manufactured with CRCA sheet, control panel having following features :-- Water and Lub oil drain outlets located on the outer surface -leading to case of maintainence and cleanliness.-MCCB of suitable rating with short circuit protection.-Controller which displays voltage, current, KW, PF, Frequency, KWh, indication lamp for \\"Load on\\" and \\"Set Running\\"-Current transformers of suitable ratings-Control fuses duly wired and Ferruled. |
| 56 | (f) MOUNTING ARRANGEMENT :- Prime mover and alternator shall be mounted on skid mounting type base frame fabricated from ISMC channel or in sheet metal providing common bed for engine and alternator directly coupled together the base frame has provision for grouting on foundation bolt as well as fixing on vibration mounts provision is made in base frame for tilting arrangement of DG set as recommended by manufacturer the base frame shall have provision for mounting of acoustic enclosure. The base frame to have provision of lifting hook for convenient lifting of complete set i.e. along the canopy engine and alternator.(g) Spares to be supplied :-(i) V-Belt -01 No(ii) Oil temprator gauge -01 No(iii) Bye-pass filter -02 Nos(iv) Fuel pump filter -03 Nos(v) Air filter 01 Set(vi) Flexible pipe (Small & long) -02 Set EachNotes:-(i) The contractor shall get the approval of GE for the make of the DG set before procurement.(ii) Prior to manufacturing the general arrangement drawing design details of the DG Set and AMF panel shall be got approved from GE.(iii) Spares to be provided as per above list.(iv) Operation and maintenance manual/catalogues,operating tools and overhauling manual to be provided. |
| 57 | SIGNAGE BOARDS&F signages board of size exc 0.04 sqm but n.exc 0.06 sqm using photo-luminescent sheet, pasted on thisck aluminium sheet of 2mm thick & inscription (i.e Emergency exit, Fire alarm, Fire point, lift etc) made by the way of computerized Vinyl cutting & lamination, including necessary fittings for fixing the board complete all as specified and directed. |
| 58 | S&F signages board of size exc 0.50 sqm but n.exc 0.60 sqm using photo-luminescent sheet, pasted on thisck aluminium sheet of 2mm thick & inscription (\\"IF FIRE OCCURS\\" necessary data will be given at execution time by Engr-In-Charge) made by the way of computerized Vinyl cutting & lamination, including necessary fittings for fixing the board complete all as specified and directed. |
| 59 | SMART METER Supply, Installation, Testing and commissioning of Single phase, two wire, tamper proof Smart prepaid, system WAN communication based, AC single phase, Two wire, 240 V AC, 50 Hz, current rating 10 -60 Amps having accuracy class 1.0 with tamper proof meter box, conforming to relevant indian standard IS-16444 and relevant IEC standards with dual mode (Credit/Prepay) support. Smart prepaid energy meter must have the following:- (a) Capaciive Touch/Push button keypad in meter, Calibration LED & Load controlling feature and provision of TOD( Time of Day) tariff & R.T.C (Real time clock) (b) Additional bluetooth features must be enabled in meter for manually and remote vending token transfer and ABC( Authenticated Billing Code) reading collection through remotely ( Mobile app suitable for android/Ios/Windows phone) (c) Provided mobile app should have a provision of Offlione & Online vending token process. (d) SMS facility for providing the vending token to consumer mobile number provision should be there. (e) All Prepaid meters should be provided with integrated cloud system for smart prepaid energy meter. |
| 60 | Supply fixing testing and commissioning and configuration of Meter Data Management (MDM) system local server base software with Life time license along with assigned grouping/ user level modules optional web based full fledged utility software with Lifetime license for MDM software with following modules:(i) Meter Data Management ModuleThe meter data management module would be deemed for collecting the data from the meter and sending to DCU/server directly and vice versa , make the data available in bidirectional mode to the currency recharge, online payment gateway, post paid billing modules, scheduling maintenance, low balance warning, quarter wise KVA allocation/tripping, tariff regulations, software customisations etc all as directed by the Engr-in-Charge. (ii) Secured mobile app/PC absed/Swipe machine/Online payment gateway for all users assigned by Engineer-in-charge.(a) 30 min instantenous data from all the meters for minimum seven parameters- Cumulative Energy, Power, Current, Voltage, Power Factor and Frequency.(b) Abstract Download for Monthly and quarterly billing survey data for cumulative energy and max demand and tampering features(iii) Billing Module: The billing module capable to create data sheet for currency recharges, recharge history, maximum demand individually, user complaints registers, cheque/payment reconciliations, fixed charges, energy bill details etc. |
| 61 | (iv) Occupation and Vacation Module: Provision to enter admin controls for transfers/vacations. The system would support occupation/ vacation based on the unit categories. The system would support automatic data capture on occupation and vacation events.(v) Customer Module: The system would include a customer portal for the resident /occupant to log in and view their own energy / billing data. (vi) Energy Accounting ModuleThe system would include features of energy accounting/audit. The system would be able to account for total energy block wise, facility wise and would also allow calculations of unaccounted energy in case tally with incomer EB energy meter. (vii) Communication ModuleThe system would provide communication of energy data and bills via print, email and sms methods. (viii) Meter Master Data: The system would support meter master data repository. The system would support meter replacement process.(ix) Excel Export:The system would support export of metering and billing data in excel format to ERP. |
| 62 | Note:1) Cyber Audit: Audit of Software for Smart Meters will be done by CERT-India Empanelled firm/CERT Auditor of Armed Forces. The cost of Audit shall be borne by the contractor.2) Cyber Security: The following guidelines/strategies shall be taken care of by the AMISP/Contractor for making the entire AMI system including the service provider immune to Cyber Attacks:a) All the hardware, OD and application software shall be hardened.b) Application, scanning and hardware scanning tools shall be provided to identify vulnerability and security threats.c) Data shall be encrypted at system/device/technology level.d) While procuring cyber security items testing must be done and the system must be secure by design.e) Residual information risk shall be calculated by Contractor and same shall be submitted for perusal of Cyber Audit Teams.f) Penetration and vulnerability assesment test from Certified auditors during feild acceptance test (FAT) site acceptance test (SAT) and Operation and Maintenance period. |
| 63 | Supply, instalaltion,testing and commissioning of outdoor DCU (Outdoor Gateway) for long range communication up to 1 km suitable for communicating with Pre paid cum postpaid meter compatible only with LORA communication protocol and the data transfer to the Theiox software complete including hosting, GPRS charges,/communication charge for three years all as specified and directed by engineer in charge. NOTE:-The cost of pole/fixing mounting arrangement on which the accumulator is to be installed and SMPS power supply with power backup for minimum up to 3 hours is deemed to be included in the unit quoted rates. |
| 64 | General Note:Certain DO's and DONT's have to be strictly implemented to ensure Privacy and Security of Consumers: DO's:A) User ID must not reveal identity and loactions.B) User ID to be kept in confidentiality by Competent Authority mantaining the overall system.C) Any breach of information from Server/Cloud should Immidiately be reported to Local Military Authority.D) Sys Logs by Installing SIEM log collectors should be in place to mantain records.E) Regular Change of passwords in Imperative System driven periodic change of passwords to be ab-initio built into the application. DONT's:A) No personal identifiable information (PIIs) to be used in the system.B) Tampering of Meter.C) Disclosure of information of consumer to anybody other than the consumer.D) Access to servers by only authorised person. |
| 65 | M & L Earth continuity conductor galvanised iron strip 32x6mm buried in ground, to be fixed on porcelain insulator with GI nuts, bolts and washers or any other indicated situation with all accessories complete all as specified and as directed. |
| 66 | Note:- Schedule of credit (Sch 'A' Part- XVIII) amount of Rs 2,93,026.30 shall be deducted from the total quoted amount of BOQ. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
| 9 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail