| 1 | Extention of the guesthouse dining area by including the adjacent portico area outside the guest house dining hall to increse dining area space at IPR Campus, Bhat, Gandhinagar-382428. |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stoneaggregate 20 mm nominal size derived from natural sources) |
| 5 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form work for :Foundations, footings, bases for columns etc. |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 8 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 9 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing,paneling and dash fasteners to be paid for separately) :NOTE: All fitting works shall be carried out as per I.S specifications including necessary rivets, screws, lugs, scaffolding, etc., complete all generally as per drawings. The sizes of the components should confirm as per details in drawings. The cost also included for sliding arrrangements including locking arrangements of sliding window.For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 10 | Providing and fixing of frame work (Styles and rails) for Doors shuters / window shutters with required sections including providing all items and hinged / pivoted arrangements for operation of shutters and cost for fixing of sliding arrangements etc., complete. (Aluminium beadings and glazing clips measured under this item only). For the detail specifican, you will cansider the spefication of item number 8. |
| 11 | Providing and fixing hinges of Stainless steel of size 100mm*58mm*1.9mm including bolt, SS screw and other necessary connections and as directed by EIC. |
| 12 | Providing and fixing aluminium handles of 200 mm size, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 13 | Supplying and fixing Chromium plated Brass lock 6 levers 100mm of approved quality aluminum door lock with two keys, suitable either to single or double leaf shutters including removing of existing old door lock from existing door frames, making necessary recess in existing aluminum frame and fixing the new door lock with CP. Brass steel screws, etc.; complete as directed by Engineer-in-charge. |
| 14 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 300x10 mm |
| 15 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 16 | Supplying and fixing Heat strengthened, (Toughened) hard coated glass of temperable 5 mm thick heat reflective glass of approved colour including providing and fixing EPDM rubber / neoprene gasket of approved quality and fixing with Aluminium glazing clips / Aluminium beadings (Supply cost of Aluminium clips / Aluminium beadings are measured in separate items mentioned above for DOORS / WINDOWS / PARTITIONS etc., ), scaffolding for any heights, leads and lift. (Measurement will be taken for length and breadth of the fixed glass) |
| 17 | Providing and filling silicon sealant at the joint of aluminum and plaster of size 5 mm x 5 mm in triangle shape to make the surface water leakage proof at periphery of window and others from inside and outside both etc., as directed by EIC. NOTE: Including scaffolding, curing etc. |
| 18 | P/F 50 MM PUF insulated Panel with flat Ribbed sheet at top and bottom side 0.45 mm TCT color Coated GI Sheet with PUF as Insulation Sandwich Panel in between including closing of all the ends of PUF using appropriate GI sheet of required size and shape, the panel should be manufactured by pressure injection of CFC free Polyurethane foam at 38 + 2 Kg/m3 density, in between the outer and inner steel sheet surfaces and should be supplied in single length up to 12.00 meter or as desired by Engineer in charge. The sheet shall be fixed using self-drilling/self-tapping screws of size (5.5 x required length) with EPDM seal, silicon sealant at joints complete up to any pitch in horizontal/vertical or curved surfaces excluding the cost of purlins, rafters and trussed and including cutting to size and shape wherever required including all materials labour, scaffolding, wastage, tools, tackles, equipment, transportation all complete as directed by engineer-in-charge. All overlaps shall be sealed with silicon sealants. Roof should be water tight. The PPGI Sheets shall be of minimum 240 MPA Steel grade & shall have a Zinc Coating of minimum 120 GSM as per IS 277/1992, 5-7 Microns of epoxy primer on both sides of the Sheet & Polyester top Coat of 18-20 microns on one side/outer side. The PPGI Sheets/PUF Panels shall have a protective guard film of minimum 20-25 microns to avoid scratches to finished panel during transportation. |
| 19 | Providing and fixing of full threaded Anchor fastner rod- M10 x 115 (Material-Carbon steel of grade C 4.8 or above and Zinc plated ) with Epoxy resin anchor grout chemical (for RCC-High loading capacity, Non corrosive for rebar element, Approved by European technical assessment, Fire resistance) and for Brick Masonary- (Fire resistance and high corrosion resistance) - HIT-RE-500 Epoxy chemical or equivalent including drilling in R.C.C. etc., for all height and levels etc., The installation and the setting instructions of anchor fastner and chemical should be strictly followed as per the manufacturer’s recommendations. Complete all as instructed and directed by Engineer-in-charge. The Payment shall be made on the actual quantity of bolts fixed at the site. Please Enable Macros to View BoQ information |
| 20 | Providing and fixing of full threaded Anchor fastner rod- M10 x 115 (Material-Carbon steel of grade C 4.8 or above and Zinc plated ) with Epoxy resin anchor grout chemical (for RCC-High loading capacity, Non corrosive for rebar element, Approved by European technical assessment, Fire resistance) and for Brick Masonary- (Fire resistance and high corrosion resistance) - HIT-RE-500 Epoxy chemical or equivalent including drilling in R.C.C. etc., for all height and levels etc., The installation and the setting instructions of anchor fastner and chemical should be strictly followed as per the manufacturer’s recommendations. Complete all as instructed and directed by Engineer-in-charge. The Payment shall be made on the actual quantity of bolts fixed at the site. Please Enable Macros to View BoQ information |