| Sl. No. | Item Description |
| 1 | Civil Work : Earth work in excavation of foundation in hard soil within 50 m linital lead and 1.50m initial lift including rough dressing breaking clods to maxikum 5cm to 7cm and laying in layers not exceeding 0.3M depth and as per OPWD Specification and direction of the Engineer-In-Charge. |
| 2 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as per OPWD Specification and direction of the Engineer-In-Charge. |
| 3 | Carriage of earth by mechanical means for site leveling, foundation, pits, trenches and other civil works upto and including 1.5 mter lift and stacking the soild upto a lead of 100 meter and including dewatering, removing slush, shorting and shutterng (as required) complete as per specification and as per the OPWD Specification and direction of the Engineer-in-charge. |
| 4 | Filling in foundation and plinth with sand including watering and ramming with cost, conveyance, royalty, taxes of all materials with all labour, T&P etc., complete as per the OPWD Specification and direction of the Engineer-in-charge. |
| 5 | Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the OPWD Specification and direction of the Engineer-in-charge. |
| 6 | Fly Ash Brick masonry in C.M. (1:6) using 9\\" size using of 23cmx11cmx8cm size brick in F&P having a crushing strength of not less than 75 kg per Sq.cm including splays, cuttings, circular moldings, watering & curing for 7 days, cost, conveyance, royalties of all materials, labour with T&P etc. complete in all respect as per the OPWD Specification and direction of the Engineer-in-charge. |
| 7 | Fly Ash Brick masonry in C.M. (1:6) using 9\\" size using of 23cmx11cmx8cm size brick in Super Structure having a crushing strength of not less than 75 kg per Sq.cm including splays, cuttings, circular moldings, watering & curing for 7 days, cost, conveyance, royalties of all materials, labour with T&P etc. complete in all respect as per the OPWD Specification and direction of the Engineer-in-charge. |
| 8 | Ground Floor |
| 9 | First Floor |
| 10 | Second Floor |
| 11 | Head room |
| 12 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 25 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 %) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge.. But excluding cost and conveyance of HYSD bar and binding wires and labour charges for straightening, cutting, bending etc. of HYSD Bar tying the grills and placing in proper position |
| 13 | Column base |
| 14 | Plinth beam |
| 15 | Column S/S & Roof Beam |
| 16 | Ground Floor |
| 17 | First Floor |
| 18 | Second Floor |
| 19 | Head room |
| 20 | RCC Wall for Lift |
| 21 | Ground Floor |
| 22 | First Floor |
| 23 | Second Floor |
| 24 | Lintel |
| 25 | Ground Floor |
| 26 | First Floor |
| 27 | Second Floor |
| 28 | Head room |
| 29 | Chajja |
| 30 | First Floor |
| 31 | Second Floor |
| 32 | Head room |
| 33 | Roof slab |
| 34 | Ground Floor |
| 35 | First Floor |
| 36 | Second Floor |
| 37 | Head room |
| 38 | Staircase |
| 39 | Ground Floor |
| 40 | First Floor |
| 41 | Second Floor |
| 42 | Supplying cutting, bending, binding & straightening coiled or bent up HYSD Bar of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL (grade Fe-500D) etc. including bending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of HYSD Bar and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for HYSD Bar only) etc. complete as per OPWD specification & direction of Engineer-in-charge. |
| 43 | Ground Floor |
| 44 | First Floor |
| 45 | Second Floor |
| 46 | Head room |
| 47 | Providing 6 mm thick C.P. with C.M. (1:4) with screened and washed sharp sand for mortar and finished smooth over RCC surface in all heights including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties and of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge |
| 48 | Ground Floor |
| 49 | First Floor |
| 50 | Second Floor |
| 51 | Providing 12 mm thick C.P. with C.M. (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties and of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge |
| 52 | Ground Floor |
| 53 | First Floor |
| 54 | Second Floor |
| 55 | Head room |
| 56 | Providing 16 mm thick C.P. with C.M. (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge |
| 57 | Ground Floor |
| 58 | First Floor |
| 59 | Second Floor |
| 60 | Head room |
| 61 | Providing 2.5 cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge |
| 62 | Second Floor |
| 63 | Head room |
| 64 | Finishing to exterior wall surface with 2 (two) coats of weather seal coat of approved shade and approved make to give an even shade after scrapping old paint with scrapper, washing with soda water, priming with approved new primer including cost of all material of all materials and labour with T&P etc. complete as per OPWD specification & direction of Engineer-in-charge |
| 65 | Ground Floor |
| 66 | First Floor |
| 67 | Second Floor |
| 68 | Head room |
| 69 | Finishing to interior wall surface with 2 (two) coats of Plastic Emulsion (P.E) Paint including cost of all material of all materials and labour with T&P etc. complete as per OPWD specification & direction of Engineer-in-charge |
| 70 | Ground Floor |
| 71 | First Floor |
| 72 | Second Floor |
| 73 | Head room |
| 74 | Finishing surface of walls with Acrylic putty of approved make and finishing the surface smooth and even by sand papering to receive paint in walls, at all heights with staging for all floors wherever necessary with cost, conveyance, of all materials, cost of all labour, all T&P etc. required for the work complete in all respect as per OPWD specification & direction of Engineer-in-charge for all floors |
| 75 | Priming one coat to the wall surface including cost of all materials and labour with T&P etc. complete as per OPWD specification & direction of Engineer-in-charge |
| 76 | Ground Floor |
| 77 | First Floor |
| 78 | Second Floor |
| 79 | Head room |
| 80 | Supplying, fitting and fixing of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar of 10mm as per approved drawing and design with cost of all labour, materials & T&P, sundries etc. complete in all respect as per OPWD specification & direction of Engineer-in-charge |
| 81 | Enamel painting two coats over a coat of primer to Iron work including cost of all materials and labour with T&P etc complete in all respect as per OPWD specification & direction of Engineer-in-charge |
| 82 | First Floor |
| 83 | Second Floor |
| 84 | Head room |
| 85 | Providing, fitting , fixing of WPC Choukaths 50 x 125 mm door including cost of labour, T&P hire charges of drilling machine labour charges etc complete in all respects as per OPWD specification & direction of Engineer-in-charge |
| 86 | Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. completeas per OPWD specification & direction of Engineer-in-charge |
| 87 | Supply and fitting, fixing of un-plasticised Po+ly Vinyl Chloride (UPVC) (FENESTA / NCL VEKA Ltd) Three Track - Three Panel sliding window - 60 Series duly manufactured using UPVC reinforced profiles of 108mmx45mmx2.5 mm for outer frames, 38mmx58mmx2.5mm capable of mounting single glazing system, structurally reinforced with hot dip galvanished upto 50 microns of minimum thickness of 1.5mm prefebricated and welded through fusion welding the window sash shall be fitted with 6 mm thick clear toughened glass of SAINT - GOBAIN make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminum 1 No per set or sashed and the system is to be installed at the site using Reinforced Large Coupler at the site using anchor fasteners, silicon rubber sealant, easy glazing / deglazing at site etc, including cost and consveyance of all materials accessories labour charges, materialsn and product conforming to ASTM D 638-14, EN-477-95 and other applicable codes and standards as per OPWD specification & direction of Engineer-in-charge |
| 88 | Supply and fitting, fixing of un-plasticised Poly Vinyl Chloride (UPVC) (FENESTA / NCL VEKA Ltd) Ventilator / Top Hung - 60 Series duly manufactured using UPVC reinforced profiles of 60mmx55mmx2.5 mm for outer frames, 75mmx60mmx2.5mm for casement Window Sash Profile capable of mounting single glazing system, structurally reinforced with hot dip galvanished upto 50 microns of minimum thickness of 1.5mm prefebricated and welded through fusion welding the window sash shall be fitted with 6 mm thick clear toughened glass of SAINT - GOBAIN make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminum 1 No per set or sashed and the system is to be installed at the site using Reinforced Large Coupler at the site using anchor fasteners, silicon rubber sealant, easy glazing / deglazing at site etc, including cost and consveyance of all materials accessories labour charges, materialsn and product conforming to ASTM D 638-14, EN-477-95 and other applicable codes and standardsas per OPWD specification & direction of Engineer-in-charge |
| 89 | Supplying, fitting, fixing of Vitrified floor tiles in Floor of premium grade having thickness 8 mm to 10mm confirming to IS 15622:2006 (Group-B la) of 600mmx600mm Coloured / Printed series (Homogeneous) laid on 20mm thick bed of cement mortar (1:4) and filling jointed with white cement of approved quality including cost, conveyance of all materials, cost of all labour, T&P etc. complete as per OPWD specification & direction of Engineer-in-charge |
| 90 | Ground Floor |
| 91 | First Floor |
| 92 | Second Floor |
| 93 | Supplying, fitting, fixing o f Vitrified industrial floor Tile of premium grade having thickness 8mm to 10mm confirming to IS 4457 of size 300mmx300mm tile in Floors laid on 20mm thick bed of cement mortar (1:4) and filling jointed with white cement of approved quality including cost, conveyance of all materials, cost of all labour, T&P etc. complete as per OPWD specification & direction of Engineer-in-charge |
| 94 | Ground Floor |
| 95 | Supplying, fitting, fixing of Granite tile of size above 0.10 Sqm and upto 0.4 sqm (10mm thick) laid on 20 mm thick Cement mortar (1:4) in floors with jointed with neat cement slury mixed with pigment to match the shades of tiles including rubbing and polishing etc complete including cost, conveyance of all materials, cost of all labour, T&P etc. complete as per OPWD specification & direction of Engineer-in-charge |
| 96 | Ground Floor |
| 97 | First Floor |
| 98 | Second Floor |
| 99 | Supplying, fitting, fixing of Vitrified floor tiles of premium grade having thickness 8 mm to 10mm confirming to IS 15622:2006 (Group-B la) of 600mmx600mm Coloured / Printed series (Homogeneous) in Dados on 12mm thick cement plaster (1:3) jointed with neat cement slury mixed with pigments to match the shades of tiles including cost, conveyance of all materials, cost of all labour, T&P etc. complete as per OPWD specification & direction of Engineer-in-charge |
| 100 | Ground Floor |
| 101 | First Floor |
| 102 | Second Floor |
| 103 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand ralling using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm X 32mm X 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm X 32mm X 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes, all materials, labour, T&P etc. required for the complete in all respect.as per OPWD specification & direction of Engineer-in-charge |
| 104 | Ground Floor |
| 105 | First Floor |
| 106 | Second Floor |
| 107 | Providing Antitermite treatments as per ISI specification including makig hols 3'0\\" C/C both ways injecting cemical with water in properation (1:20) or any approved propertion by the Engineer-in-Charge and treatment to choukath sides and wall juction cost and conveyance of all materials, labours, R&P etc completionas per OPWD specification & direction of Engineer-in-charge |
| 108 | Cement concrete of proportion (1:2:4) in F&F using 12mm size crusher broken chips of approved quality including cost, conveyance, royalty of all materials and labour with T&P etc. Complete. as per OPWD specification & direction of Engineer-in-charge |
| 109 | Head Room |
| 110 | E.I. Works : Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.GROUP-A |
| 111 | Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.GROUP-B |
| 112 | Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.GROUP-C |
| 113 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 114 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (flame retradant type)) with suitable size modular box & cover( falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 115 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((flame retradant type)) with suitable size modular box & cover(flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 116 | Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( (flame retradant type) with suitable size modular box & metallic cover plate (both side)( falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 117 | Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( (flame retradant type) with suitable size modular box & metallic cover plate (both side)( falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 118 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 119 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 120 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 121 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5) |
| 122 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4) |
| 123 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6) |
| 124 | Supplying and fixing of following sizes of HMS PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/BEC/Precision/Norpak/Kinjal.(Only for data, telephone, CCTV)20MM |
| 125 | Supplying and fixing of following sizes of HMS PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/BEC/Precision/Norpak/Kinjal.(Only for data, telephone, CCTV)25MM |
| 126 | Supplying and installation of 25A AC starter Modular type, Schneider/Siemens/Legrand coil voltage-230 Volt A.C. on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 127 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make-Schneider (Zencelo)/ legrand( ( Myrius)) /Panasonic (vision)as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 128 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 129 | (Light fitting Fixture & Fan)Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 130 | Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers(Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 131 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. .(With fan Regulator) |
| 132 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 133 | Supplying an fixing of recess/surface mounted 2'x2' 25 W(595mmx595mmx70mm) square shaped LED with lumen efficacy not less than 130lm/W, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 5 years. |
| 134 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 135 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge (Make: legrand Myrius /Schneider(Zencelo)/Panasonic(Vision)) |
| 136 | DBSSupplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years (FOR LIGHT,ComputerDB) |
| 137 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.8 Way(8+24) Way TPN MCB DD DB Horizontal Type suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR POWER & INDOOR AC DB)Warranty on DB is 3 years (CONFERENCE ROOM) |
| 138 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years |
| 139 | MCB AND RCCBSupplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 230 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 year.. |
| 140 | Supplying and fixing 40 amps rating, 415 volts, C series,10KA breaking capacity, FOUR poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 /ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 141 | Supplying and fixing 40 Amps rating, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 142 | Supplying and fixing 63Amps 4P 415 volts MCB 415 volts, C series,10KA breaking capacity, Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB with connections as per direction of Engg.-in-Charge..Warranty on MCB is 1 years. |
| 143 | Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The RCCB should be Replacement Warranty will be 1 year. |
| 144 | Supplying and fixing 40 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 145 | EARTHINGSupplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 146 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. Tapping from 50mm x 6 mm bus bar to all sub panel |
| 147 | Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. 2 runs from main LT room to electrical shaft upto 5th floor |
| 148 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5core x 150 sq mm |
| 149 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5core x 50sq mm FDB POWER |
| 150 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5core x 25 sq mm FDB LIGHT |
| 151 | LAYING OF CABLELaying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 152 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 153 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 154 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 155 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 156 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in open duct etc as required as per direction of Engg.-in -charge. |
| 157 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 158 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 159 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 160 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 400 SQ. MM From 120 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 161 | TERMINATION OF CABLESSupplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 3.5 core x150 sq mm |
| 162 | TERMINATION OF CABLESSupplying and making end termination with brass double compression gland and aluminium lugs for following 3.5 core x50 sq mm |
| 163 | TERMINATION OF CABLESSupplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 3.5 core x25sq mm |
| 164 | MAIN PANELS/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.60X10MM Separate Aluminium Earth bus bar should be installed. |
| 165 | In commer-1-01 number of 200(180-200) 4P Icu=100%Ics,36Ka LSIG MCCB with micro processor based release Electrical locking for normal & DG ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula |
| 166 | In commer-2-01 number of 125A(100-125) 4P Icu=100%Ics,25kA LSIG MCCB with micro processor based release Electrical locking for normal & DG ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula) |
| 167 | In commer-2- 01 no of 125A 4P onload changeover switch (160 KVA DG 01 NO)(Make-C&S/LK(L&T)/Siemens/Schneider/ABB) |
| 168 | Busbar-1&2 04 numbers of 500Amps COPPER busbar with busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) |
| 169 | Out going- 01 numbers of 100A 4P MCCB,,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula) |
| 170 | Out going- 06 numbers of 63A 4P MCCB,,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula) |
| 171 | Out going- 4 numbers of 40-63A rating,10 KA breaking capacity,C series, 4P MCB(Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB sb200) |
| 172 | Outgoing-01 number of 200A(160-200) 4P Icu=100%Ics,25kA LSIG MCCB with TMR Release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula) |
| 173 | Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse. |
| 174 | (ii) 02 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication with RS 485 COMPACTIVITY FOR bms data. |
| 175 | 1 no. 3P+N 65kA type 1+2 SPD with 63A rating,10KA breaking capacity ,4P MCB(Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200) |
| 176 | UPS PANELS/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. BUILDING VRF AC)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. Type 2 SPD 3P+N 40kA shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed. |
| 177 | In commer - 01 no 63A 4P MCCB 16kA, with ROM & S. Link. withTMR based release with adjustable overload ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula) (Icu=100%Ics)with shunt trip. |
| 178 | Busbar- 04 numbers of 250Amps, Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. |
| 179 | Out going- 04 nos 32A 4P MCB 10kA,C series,415V . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200(UPS BDB EACH FLOOR) |
| 180 | Out going- 04 nos 32A 2P MCB 10kA,C ,240V series . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 |
| 181 | Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. |
| 182 | (ii) 01 set of MFM with CTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or equievalant make & model) |
| 183 | CABLE TRAYSupplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 184 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 185 | Supplying,fixing of FLOOR RACE WAY WITH JUNCTION box GALVANIZED(GC) type AS PER EN-ISO-1461 , with internal dimensions of size 38mm(H) x 225mm(W), of MAKE- Profab/OBO/Neidax .(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTOR as required as per direction of Engg.-in-Charge. |
| 186 | GPH works : Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor PVC pipes conforming to pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge(Ashirbad/Supreme/Oripalst) In GF 20mm dia PVC ASTM (Sch-80)Pipe |
| 187 | 25mm diaPVC ASTM (Sch-80)Pipe |
| 188 | 32mm diaPVC ASTM (Sch-80)Pipe |
| 189 | In 1st Floor 20mm dia C-PVC pipe |
| 190 | 25mm dia C-PVC pipe |
| 191 | 25mm dia PVC ASTM (Sch-80)Pipe |
| 192 | 32mm PVC ASTM (Sch-80)Pipe |
| 193 | 2nd Floor 20mm dia C-PVC pipe |
| 194 | 25mm dia C-PVC pipe |
| 195 | 25mm dia PVC ASTM (Sch-80)Pipe |
| 196 | 32mm PVC ASTM (Sch-80)Pipe |
| 197 | 40mm PVC ASTM (Sch-80)Pipe |
| 198 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar ( 1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.F. Floor |
| 199 | 2nd Floor |
| 200 | Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of the Engineer in charge.F. Floor |
| 201 | 2nd Floor |
| 202 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per the direction of the Engineer in chargeF. Floor |
| 203 | 2nd Floor |
| 204 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge250mm to 375mm thick wall F. Floor |
| 205 | 2nd Floor |
| 206 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge15 mm dia CP Long body Bib cock (Jaquar)-CON-CHR-107KN |
| 207 | 15mm dia CP S.B Bib cock (CON-CHR-037KN) |
| 208 | 15mm dia CP angle stop cock (FLR-CHR-5053N Jaquar make) |
| 209 | 15mm dia CP Pillar cock (Jaquar)CON-CHR-021KN |
| 210 | 15mm dia CP two in one bib cock (FLR-CHR-5041N Jaquar make) |
| 211 | 15mm dia CP Health faucet (Jaquar- ALD-CHR-565 |
| 212 | 15mm dia CP concealed stop cock (Jaquar)CON-CHR-087KN |
| 213 | Revolving Shower with arm Jaquar Cat NO--OHS-CHR-1985 + SHA-CHR-477 |
| 214 | 25mm dia brass or gun metal fullway valve(Shakti/Leader / Kriti Make) |
| 215 | 32mm dia brass or gun metal fullway valve(Shakti/Leader / KritiMake) |
| 216 | 40mm dia brass or gun metal fullway valve(Shakti/Leader / Kriti Make) |
| 217 | 15mm dia CP flange |
| 218 | 15mm dia CP extension piece |
| 219 | Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701-1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class Fly ash brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge 2000 litre capacity water storage Sintex tank(3 layer on the roof of 2nd floor.(Supreme/Ashirvad/Oriplast) |
| 220 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge110mm dia U-PVC SWR pipes(Supreme/Ashirvad) |
| 221 | 75mm dia U-PVC SWR pipes(Supreme/Ashirvad) |
| 222 | 50 mm dia UPVC Class-IV Pipe |
| 223 | 100mm dia U-PVC 'P' trap |
| 224 | 110mm dia U-PVC Door Tee |
| 225 | 100mm dia U-PVC Plain Bend |
| 226 | 100mm dia U-PVC Door Bend |
| 227 | 100mm U-PVC Door Cross Tee |
| 228 | 75mm dia U-PVC Door Bend. |
| 229 | 75mm dia U-PVC Plain Bend. |
| 230 | 110x75mm dia Reducer |
| 231 | 110mm dia Vent cowl. |
| 232 | W/C connector |
| 233 | PVC Clamp suitable for 75mm to 110mm dia pipe |
| 234 | 125mm dia CP grating |
| 235 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C. pan) of (Parryware/Hindware/Cera/Somany/Kerovit) with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer-In-Charge.EWC with 'S' trap plain (Parryware/ Hindware/ Cera/ Somany/ Kerovit) |
| 236 | One piece commod(Hindware)ELEMENT Cat No.92084. |
| 237 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make), etc all complete as per specification and direction of the Engineer in chargeHalf pedestal Basin(Hindware)No.91049+91115 |
| 238 | Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in chargeDesign mirror(Parryware) |
| 239 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification and direction of the Engineer in chargeGlass shelf 600mm long(ACN-CHR-1171N) |
| 240 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge25mm x 600mm long CP towel rail (Jaquar) ACN-CHR-1111SM |
| 241 | Towel Ring Round - (As Per Jaquar,Cat no.:ACN-CHR-1121BN) |
| 242 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge CP soap holder AKP-ABR-35731P(Jaquar make) |
| 243 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge F. Floor |
| 244 | 2nd Floor |
| 245 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. F. Floor |
| 246 | 2nd Floor |
| 247 | Supplying the waterproofing material Pidifin 2K of Dr.fixit on equivalent water proofing material and appling in two coat over the concrete floor and dado upto 1\\"-6\\" in wall including cleaning,applying and mending as per specification including all labour charges as per direction of Engineer-in-charge.1st Floor Wall - |
| 248 | 2nd Floor Wall - |
| 249 | Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge Kajaria of size 600 mm x 300 mm Of Durenmarfil or equivalent make.F. Floor |
| 250 | 2nd Floor |
| 251 | Supplying all materials, labour, T&P and providing ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. size 600 x 600 mm Kajaria of Fogparla or equivalent .F. Floor |
| 252 | 2nd Floor |
| 253 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. |
| 254 | Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge |
| 255 | EXTERNAL P.H. WORK. |
| 256 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.110mm all round concrete |
| 257 | 160mm all round concrete |
| 258 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, Fly ash brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge. Inside size 250mmx250mm |
| 259 | Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, Ground class fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm |
| 260 | Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in chargeMan hole chamber Inside size 910mmx910mmx910mm |
| 261 | Cost of R.C.P.C.Cover. |
| 262 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class Fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in chargeBrick masonry soakway pit 1.40m dia x 2.00m deep |
| 263 | Construction 1 nos 20 users RCC Septic tank |
| 264 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge. |
| 265 | - do - with addl. Depth of 1.5 m |
| 266 | Excavation of foundation in laterite rock or any hard rock (other than granite or disintegrated rock) removed by chiselling including dressing and levelling the bed not exceeding 1.50 mtr. in depth and depositing the soil within initial lead of 50 mtr. and as per specification approved by the Department. |
| 267 | Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge |
| 268 | In ground floor |
| 269 | Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. |
| 270 | In ground floor |
| 271 | Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 272 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 273 | Roof Slab- |
| 274 | For RCC wall |
| 275 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 276 | Supplying all materials,labour,T&P and providing 6mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 277 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 278 | Supplying all materials, labour, T&P and fitting and fixing S.W.Tee of size 160mx160mx160m as per P.H.D.specification and direction of the E.I.C. |
| 279 | Supplying all materials, labour, T&P and constructing vent base as per P.H.D specification etc all complete. |
| 280 | Supplying all materials, labour, T&P and fitting and fixing UPVC SWR soil waste ventilating pipes and fittings to walls with nails, bobbins and wooden plugs or laying in trenches including earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. |
| 281 | 110mm diameter U-PVC SWR pipe |
| 282 | 110mm dia U-PVC Plain shoe bend |
| 283 | 110mm dia U-PVC Cowl |
| 284 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 285 | 1 x2 x(3.00+1.50) x 0.15 x 2.00 |
| 286 | Sinking of (200 x150)mm dia bore well - 1 No by DTH method. |
| 287 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below first level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only |
| 288 | Drilling of 200mm dia bore 00 mtr to 45mtr |
| 289 | Drilling of 150mm dia bore 45 mtr to 150mtr |
| 290 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from first level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. |
| 291 | Lowering of 200mm dia P.V.C casing pipes |
| 292 | 00 mtr to 45 mtrs |
| 293 | Cost of 200mm dia PVC (sch-80) pipe |
| 294 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge |
| 295 | By DTH Rig |
| 296 | Supplying all materials, labour, T&P and constructing Bore well protection chamber of the inside size 650x650x1000hight with cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ash brickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:4) inside and outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. |
| 297 | Supply all materials, labour, T&P and providing,fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specifications with suitable control pannel, jointing with GI/PVC/HDPE pipes electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge. 1.00 H.P single phase 3 stage head range 20 to 35 metres, discharge 145 to 110 L.P.M with outlet dia of 25mm |
| 298 | DOL controll pannel |
| 299 | 2.5 Sqmm flat cable |
| 300 | 32mm dia Steel short piece |
| 301 | Steel roop with cover |
| 302 | Well cap |
| 303 | 50mm size CI bracket |
| 304 | 20mm dia rigid UPVC pipe |
| 305 | 32mm Dia brass non return valve(Shakti make) |
| 306 | 32mm dia HDPE pipe |
| 307 | Labour charges for lowering of submesible pumpset with pipes and cables etc. with testing and commissioning at site. |
| 308 | Construction of 6.75mx3.60m x 1.40m(h) Rain water harvesting system 1no |
| 309 | Sinking of tube well through D.T.H.Rig. |
| 310 | 200mm dia- 0.0m to 30.00m |
| 311 | Lowering of PVC casing pipe inside bore. |
| 312 | 200mm dia- 0.0m to 30.00m |
| 313 | Cost.of 200mm dia (Sch.80)Pipe |
| 314 | Cutting slot in casing pipe for recharge of rain water |
| 315 | Labour for packing gravel outside the tube well |
| 316 | 25.0mx22/28{(0.40)²-(0.20)²} |
| 317 | Cost of washed gravel. |
| 318 | Earth work in all kinds of soil within 50 mtr initial lead and 1.5mtr initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3 mtr in depth and as per direction of the Engineer in charge. |
| 319 | Supplying all materials, labour, T&P and providing cement concrete (1:4:8) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 320 | Supplying all materials, labour, T&P and providing brick work with Fly ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:6) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 321 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 322 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 323 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 324 | Roof slab- |
| 325 | Supplying all materials, labour, T&P and providing reinforced cement concrete work of M-25 grade with 20mm and down grade black hard granite crusher broken stone chips including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 326 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 327 | Providing and filling filter media |
| 328 | 40mm size bolder-1x6.0x2.50x0.85= |
| 329 | 20mm size washed gravel-1x6.0x2.50x0.40= |
| 330 | Course sand-1x6.0x2.50x0.30= |
| 331 | Providing fitting and fixing M.S.grill,Jalli cover over the harvesty pindi |
| 332 | CONSTRUCTION OF 10000 LTR RCC SUMP 1nos |
| 333 | Earthwork in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to minimum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer in charge. |
| 334 | Initial lift - |
| 335 | Earthwork in excavation of foundation in stonety earth mixed with gravel within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to minimum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer in charge. |
| 336 | 1st Extra lift - |
| 337 | Supplying all materials, labour, T&P and providing filling sand including watering, ramming and conveyance of all materials to site. |
| 338 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 40mm H.G metal including watering, curing and conveyance of all materials to site. |
| 339 | Supplying all materials, labour,T&P and providing cement concrete (1:1.5:3) for RCC work using 12mm HG chips including hoisting,laying,curring and conveyance of all materials to site etc complete. |
| 340 | Supplying all materials, labour, T&P and providing brick work with Fly ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:3) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 341 | Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage. |
| 342 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor. |
| 343 | RCC walls |
| 344 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:3) including watering,curring and conveyance of all materials to site. |
| 345 | Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site. (1no) |
| 346 | Supplying all materials, labour, T&P and futting and fixing 20mm dia MS/CI step iron including supply of necessary C.C(1:2:4) for fixing etc complete as per P.H.D. specification. (1no) |
| 347 | Supplying all materials, labour, T&P and cleaning of debries,uprooging and disposing at a safe distance all complete as per direction of the Engineer in charge |
| 348 | Sweeper |
| 349 | Supplying all materials, labour, T&P and constructing surface drain of size A-4 type with cement concrete (1:3:6) using 12mm size h.g chips on bed, 1st class Fly ash brickwork in cement mortar (1:3) inside, 12mm thick cement plaster (1:3) finished smooth with cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.Surface drain of size A-4 type |
| 350 | Supplying all materials, labour, T&P and providing fitting and fixing Aquaguard PRO Thermapure 120 PSS RO ACH which gives you Hot,Cold & Ambient purified water.Aquaguard PEO Thermapure 120 PSS RO has built-in-3 stage combinations,Tank Capacity 120Ltr.,Cold Water-80 Ltrs,Hot water-20 Ltrs.,Ambient water-2- Ltrs.,Cooling capacity-60 LPH,Refrigerant-HFC R134a,Cold water temperature-15 Deg.C+/-1*,Heating coil wattage-2000W,Hot water temperature-50 Deg C+/-1,Thermal insulation-PUF,No of Faucets-1 Hot,1 Cold,1 Ambient,Tank,front panel and drain tray MOC-SS304,Other body panels-Powder coated CRCA Steel,No of filtration stages-7,RO Capacity-50 LPH*,RORecovery%-50%*,TDS Reject-90%*,Dimentions(WxDxH)cm-75x72x144,Net weight-92 Kg.etc.all complete as per direction of the Engineer-in-charge. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |