| 1 | Excavation in soil in Hilly area by mechinical /Manual means in all heights and depths all kinds of soil such as a pick work , jumper work , blasting work both in soft and hard rock with chiesling / wedging out rock (where blasting is prohibited ) and other intermediate classification of soil including cutting and trimming of side slopes and disposal unserviceable material by mechnical transport to designated dumping site and stacking the serviceable/ useful material as directed by the Engineer -in - Charge, muttams shall be left at suitable place as directed by Engineer- in - Charge and shall be removed only after attaining the formation level and after final checking of Engineer-in- Charge. The work shall be executed in workman like manner and avoid any damage to the private / Govt. property in the vicinity of work site , if any damage occurs to any property during the course of execution shall be the absolute responsibility of the contractor , which shall have to be duly compensated by him in all cases, including carriage of materials with in all leads, lifts and other incidentals. |
| 2 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation, trenches, drains (Any width or square metre on plan), including dressing of sides and ramming of bottoms, lift upto any height, including getting out the excavated soil and disposal of surplus excavated soil as directed in all kinds of classification, of soils such as pick work, jumper work, blasting work saturated soils including chiseling or any other mixed variety of soils, dewatering and / or removal of slush and other incidentals within all leads and lifts complete in all respect as per direction and satisfaction of Engineer-in-Charge. Any loss to the public or private property during the course of excavation shall be the sole responsibility of the contractor which shall have to be duly compensated by him at his own cost in all cases. |
| 3 | Providing and laying, mechanically mixed and vibrated cement concrete 1:5:10 (one cement : five sand : ten graded crushed stone aggregate 40 mm (forty millimeter) nominal size) in foundation and plinth including curing complete excluding the cost of form work but including carriage of material with in all leads, lift, and other incidentals complete in all respect as per direction and to the entire satisfaction of Engineer-in-Charge. |
| 4 | Providing and laying, mechanically mixed and vibrated cement concrete 1:4:8 (one cement : four sand : eight graded crushed stone aggregate 40 mm (forty millimeter) nominal size) in foundation and plinth including curing complete excluding the cost of form work but including carriage of material with in all leads, lift, and other incidentals complete in all respect as per direction and to the entire satisfaction of Engineer-in-Charge. |
| 5 | Providing and laying, mechanically mixed and vibrated cement concrete 1:3:6 (one cement :three sand : six graded crushed stone aggregate 40 mm (forty millimeter) nominal size) in foundation and plinth including curing complete excluding the cost of form work but including carriage of material with in all leads, lift, and other incidentals complete in all respect as per direction and to the entire satisfaction of Engineer-in-Charge. |
| 6 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) mechanically mixed, vibrated and curing complete as required including carriage of materials with in all leads, lifts and other incidentals or as per the direction and to the entire satisfaction of Engineer-in-Charge. |
| 7 | Reinforced cement concrete work in walls any thickness including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor all level excluding the cost of centering, shuttering, finishing and reinforcement in secified grade of reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) mechanically mixed, vibrated and curing complete as required including carriage of materials with in all leads, lifts and other incidentals or as per the direction and to the entire satisfaction of Engineer-in-Charge. |
| 8 | Reinforced cement concrete work in Beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor all levels excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) mechanically mixed, vibrated and curing complete including carriage of materials with in all leads, lifts and other incidentals or as per the direction and to the entire satisfaction of Engineer-in-Charge. |
| 9 | Providing form work with steel plates 3.15 mm ( three point fifteen millimetre ) thick welded with angle iron in frame 30x30x5 mm (Thirty millimetre x Thirty millimetre x five millimetre) so as to give a fair finish including centering, shuttering, strutting and propping etc. with wooden battens and ballies in all height of propping and centering below supporting floor to ceiling upto floor all level and removal of the same for in-situ reinforced concrete and plain concrete work including carriage of materials with in all leads, lifts and other incidentals or as per direction of Engineer-in-charge in:- |
| 10 | Foundations, footings, bases of columns, etc. for mass concrete |
| 11 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 12 | Suspended floors, roofs, landings, balconies and access platform. |
| 13 | Lintels, beams, plinth beams, girders,bressumers and cantilevers. |
| 14 | Columns, pillars, posts and struts square, rectangular or polygonal in plan as required. |
| 15 | Edges of slab and breaks in floor and walls under 20 cm wide as required. |
| 16 | Providing tor steel reinforcement TMT bars of grade Fe-500 D or more ISI make high yield strength for reinforced cement concrete work including straightening, cutting ,bending, binding and placing in position and cost of binding wire complete up to floor all levels including carriage of material with in all leads, lifts and other incidentals complete as per direction and to the entire satisfaction of Engineer-in-Charge |
| 17 | Random rubble masonry with hard stone of approved quailty in foundation and plinth including levelling up with cement concrete 1:6:12 (one cement : six coarse sand : twelve graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand) including curing complete and carriage of materials with in all leads, lifts and other incidentals, complete as per direction and to the entire satisfaction of Engineer-in-Charge. |
| 18 | Coursed rubble masonry with hard stone (first sort) in superstructure above plinth level and up to floor all levels with Cement mortar 1:6 (1 cement : 6 coarse sand) including curing complete and carriage of materials with in all leads, lifts and other incidentals. |
| 19 | Stone soiling under floor dry hand picked tightly complete in all respect as per direction of Engineer in charge including carriage of material with in all leads, lifts and other incidentals |
| 20 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including carriage of materials with in all leads, lifts and other incidentals as per direction by the Engineer-in-Charge. . |
| 21 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength including carriage of materials with in all leads, lifts and other incidentals. |
| 22 | Providing and fixing ball bearing for rolling shutters including carriage of materials with in all leads, lifts and other incidentals. |
| 23 | Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar 1:4 (1 cement : 4 coarse sand) including filling the joints with same mortar, with common burnt clay non modular bricks including curing complete and carriage of materials with in all leads, lifts and other incidentals. |
| 24 | 6 mm (six millimeter) thick cement plaster to ceiling in cement mortar 1:3 (one cement : three sand) including carriage of material with in all leads, lifts and other incidentals. |
| 25 | 15 mm (fifteen millimeter) thick cement plaster in single coat on rough / fair side of brick /concrete / stone wall for interior plastering for all floors including arises internal rounded angles chafers and / or rounded angles chamfers and / or rounded angles not exceeding 80 mm (eighty millimeters )In girth and finished even and smooth in cement mortar 1:6 (one cement : six sand ) including carriage of material with in all leads, lifts and other incidentals as per direction and to the entire satisfaction of Engineer-in-Charge. |
| 26 | Distempering two coats with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 (fifty) grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. including carriage of material with in all leads, lifts and other incidentals as per direction and to the entire satisfaction of Engineer-in-Charge. |
| 27 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture including carriage of material with in all leads, lifts and other incidentals. |
| 28 | Providing and fixing weepholes 100 mm dia PVC pipe for (D-Plast/Polyplast or equivelent ISI mark 2.50 Kg pressure) Retaining wall/brestwall in CC/RR/SR masonry as per drawing and technical specification including carriage of materials with in all leads, lifts and other incidentals. Please Enable Macros to View BoQ information |