Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Demolition of brick work or rubbled stone masonry including all quoins arches , pillars etc built in cement mortar and including removal from the site complete all as specified. |
| 2 | M&L for brick work with sub class 'B' old size brick, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:6 etc complete all as specified. |
| 3 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc and including removal of debris and rubbish from the site complete all as specified. |
| 4 | Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified. |
| 5 | M&L Rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:4) finished fair and even and using WPC, complete all as specified and directed (Note : WPC shall be measured and paid separately. |
| 6 | M&L Rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement, complete all as specified. |
| 7 | M&L Rendering 10 mm thick in cement mortar (1:3), as on concrete surfaces (such as top & sides of chajjas, beams, balcony ceiling etc.) finished even and smooth without using extra cement, complete all as specified. |
| 8 | M&L Preparing of new surface of wall and applying two coats of Cement base paint .Complete all as specified and directed |
| 9 | M & L preparation of newly plastered wall surfaces of wall and applying two coats of OBD over a coat of chalk whiting putty including preparation of surfaces on walls as specified and directed . |
| 10 | M&L for preparation of newly plastered or unplastered/undecorated surface of ceiling and applying two coats of oil bound distemper over one coat of chalk whiting putty complete all as specified |
| 11 | M&L for preparation of plastered or unplastered old decorated surfaces by complete removal of existing treatment by mechanised sander of berger paints or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and filling of holes and cracks with with suitable material like cement or plaster of paris etc and thereafter applying two coat of oil bound distemper on walls. Note : (a) Stage for Preparation of surfaces shall be got approved from Engg-In-Charge before applying the finishes.(b) Material shall be procured from manufacturer. |
| 12 | All as per item No.11 here-in-before but on surfaces of ceiling. |
| 13 | M&L for preparation(complete removal of existing treatment) of old decorated external wall/ceiling surface of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7\\"/9\\" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying Two coats of wheather proofing exterior acrylic emulsion paint over priming coat premium quality on wall/ceiling surface including applying 2mm thick wall care putty over disturbed surface during preparation of any reason, sand papering thus make surface smooth upto 4th storey buildings complete all as specified and directed. Note : (a) Stage for Preparation of surfaces shall be got approved from Engg-In-Charge before applying the finishes.(b) Material shall be procured from manufacturer and work shall be got executed through authorised applicator. |
| 14 | Pressed steel frames made out mild steel sheet 1.25 mm thick, with size of frame 125 mm x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates etc and applying a shop coat of red oxide primer including providing PCC 1:3 :6 type C-0 using 12.5 mm graded crush stone aggregate for filling back of chowkhats complete all as specified and as directed by the Engineer-in-Charge |
| 15 | Pressed steel frames made out mild steel sheet 1.25 mm thick, with size of frame 105 mm x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates etc and applying a shop coat of red oxide primer including providing PCC 1:3 :6 type C-0 using 12.5 mm graded crush stone aggregate for filling back of chowkhats complete all as specified and as directed by the Engineer-in-Charge |
| 16 | S & F 35mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; size of members of shutters as specified in SSR Part – I, Section – 8, clause 8.20 (a) ; supplied and fitted to chowkats all as specified and directed by Engineer - in - Charge |
| 17 | S & F flush shutter 35 mm thick solid core construction with block board core and plywood face panels commercial type on both sides with lipping / frame to match all as specified and directed by Engineer - in - Charge. |
| 18 | S & F mild steel tower bolts, stove enamelled black, with bright bolt and fixed, length of bolt 200mm long all as specified and directed by Engineer - in – Charge . |
| 19 | S&F 300mm Aluminium alloy, anodised,sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed |
| 20 | S & F aluminium handle cast type anodised, 125 mm long all as specified and directed by Engineer - in - Charge . |
| 21 | S & F Stainless Steel butt hinges, medium weight 100mm size all as specified and directed by Engineer - in - Charge . |
| 22 | M&L for providing plain cement concrete (1:2:4) type B0 (using 12.5 mm graded crushed stone aggregate) as in coping or roof kerbs on roof chamfered on edge including trowelling slightly complete all as specified. |
| 23 | Supply only intergral water proofing compound ISI Marked complete all as specified. |
| 24 | Taking down chowkats or frames with shutters (without taking off shutter from frames) not exc. 1.5 sqm each, including cutting holes for removing the hold fast etc (Distrubed surface of wall shall be make good by the contractor. The rate quoted shall be deemed included for the same) complete all as specified. |
| 25 | Taking down chowkats or frames with shutters (without taking off shutter from frames) exc. 1.5 Sqm but n exc 4 Sqm each, including cutting holes for removing the hold fast etc (Distrubed surface of wall shall be make good by the contractor. The rate quoted shall be deemed included for the same) complete all as specified. |
| 26 | Dismantling/removing old damaged worn out APP of any thickness incl screed bed or plastering of any thickness and removing the rubish materials outside MOD land at a dumping place earmarked marked by any state govt/municipalities etc any distance complete all as specified and as directed. |
| 27 | Cleaning the surface and made free of dirt, foreign particles, laitance followed by grinding all protrusions to make surface modulated. Thereafter, inspection for cracks on the surface caused by thermal expantion contraction. Cutting the grooves with suitable cutter machine in \\"v\\" groove filled with Repair mortar/Microconcrete/General purpose grout as recommended proportionaly as per recommendation of manufacturer.Making of Gollas at all the corners with Polymer modified mortar(1:4 Cement:sand with 3.5% Acylic of cement weigth) and \\"Supplying and applying High build elastomeric waterproofing coating based on pure, hydrophobic polyurethane, cold applied of spray / brush applied, membrane with an elongation of 280% and tensile strength of 2.7 N/mm2 as per ASTM D 2370, crack bridging ability of 3mm, no leakage upto 5 bars of water pressure as per DIN 1048, min 88 % solid content. The system includes final base preparation, epoxy primer 1:1(Resin:hardner) application with 100 % water dilution and Pure polyurethane application in 2 coats with a total min consumption of 1.25 Kg per SQM .Application should be done with Graco sprayer by a company authorised applicator. |
| 28 | 15mm thick rendering in cement mortar 1:4 on concrete/brick surfaces and rendering is to be even and fair with water proofing compound as per manufacturers instructions complete all as specified and directed by Engineer-in-Charge. |
| 29 | Dismantling wrought iron or mild steel work of any description |
| 30 | M & L Mild steel work as in roof trusses including special shaped washers etc complete using ERW or induction butt welded tubes coforming to IS 1161-1979 grade st-240 etc including a shop coat of red oxide primer complete all as speciied and directed. |
| 31 | Dismantling Asbestos cement sheet (corrugated, semi corrugated etc), plain or corrugated steel sheet in roof coverings complete all as specified. |
| 32 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 33 | S & F for Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, Fe 410-W (Gde-E-250) quality-A,etc complete all as spd and directed. |
| 34 | Mild steel framed work conforming to Fe-290 Gde E-165 quality-A as in grills, gratings etc. with ends of bars shouldered and/ or rivetted or forged into spikes; framed guard bars, walkways, railing, barred iron doors including side hung gates with pintel hinges, spops, hand made sliding bolts, framed work of water tanks, door chowkats and similar works complete all as specified |
| 35 | M&L for MS plates(plain or Chequered) conforming to Fe-290 Gde E-165 quality-A channels, square cut or notched (ordinary and counter sunked , forming holes and welded to angle/flat sections , complete all as specified and as directed |
| 36 | S&F mild steel plain black sheet 0.80 mm thick as in hearths,covering to door shutters , covering to door chowkat etc cut to size edges beaded if directed, holes punched, etc complete all specified and as directed. |
| 37 | S&F powder coated anodized aluminum frame for partition, doors, windows, ventilations with one or more rebates including joining cleat for fixing etc. complete all as specified. |
| 38 | S & F for Anodised aluminium door shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws, etc complete, as specified and directed. |
| 39 | S&F powder coated Anodised aluminium window and ventilator shutters, fixed/side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified. |
| 40 | S&F Powder coated aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge. |
| 41 | S&F for 4.8/5.0 mm thick sheet glass ordinary quality and glazing each pane n exc 0.50 Sqm fixed with neoprene rubber gasket in aluminium frame work complete all as specified. |
| 42 | S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed to steel frames with tinned tacks, or galvanized wire staples, or fixed to wooden frames with first class hard wood bead, complete all as specified and directed. |
| 43 | S & F for 5-6 mm thick aluminium composite panel sheet as in aluminium partition/aluminium door, fixed with nails to timber framework, etc completed all as specified. |
| 44 | M&L for providing for frameless glazing door including all fitting of shutter i.e handle, lock hinges etc with laminated toughened glass fitted with stainless steel spider fittings (2way/4way) splice plate, fin plate routel and stainless steel fastener etc with 12 mm thick glass support finish complete all as specified and directed. |
| 45 | S & F for Collapsible steel gates, top hung,consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, etc complete all as spd and directed. |
| 46 | M&L prepration of new Steel surfaces of any description, not otherwise described, over 10cm width or girth & applying two coats of synthetic enamel paint complete all as specified |
| 47 | Demolition of stone slabs and tiles of any description or thickness in floors/walls, aprons etc laid bedded and pointed in any mortar. |
| 48 | M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbingand polishing complete all as specified. |
| 49 | M&L Machine cut kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to mtach the shade of the slab including rubbing and polishing complete all as specified. |
| 50 | M & L Granite (of any type) work (table rubbed and polished)25 mm thick in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, etc complete all spd and directed. |
| 51 | Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the permises complete all as specified and as directed |
| 52 | M&L, Non-skid ceramic coloured tiles tiles 7 to 8 mm thick (square/rectangular) of size 400 x 400 mm , in floors etc. set & jointed in neat cement slurry & pointed in white or coloured cement over 15mm thick screed bed in CM (1:6) complete all as specified. |
| 53 | M & L for light shade , Virified Ceramic tiles 8-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 20 mm thick Screed bed or bedding layer of mortar for laying floor finishes in CM 1:6 etc completed all as specified. |
| 54 | M & L for 25mm thick PCC 1:2:4 type BO (using 12.5mm graded stone aggregate) as in sub base floor complete all as specified and directed. |
| 55 | M & L for light shade , Virified Ceramic tiles 8-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. on vertical surface set and over including 10 mm thick rendering with cement mortar (1:4) including pointing in white cement with pigment to match the shade of tiles, complete all as specified. |
| 56 | M & L first quality coloured glazed ceramic, joint free tiles fixed in pattern of different colour including border of size 300x450x7 mm thick as in vertical surfaces such as dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match with colour of tiles laid on and including 10 mm thick rendering in cement mortar (1:3), including pointing in white cement with pigment to match the shade of tiles, complete all as specified and directed. Note :- Pattern of the tiles will be decided by GE at the time of execution. |
| 57 | M&L Plain cement concrete ( 1:2:4), type B-1, (using 20 mm graded stone aggregate) as in surface channels and drains, benching of manholes laid to shape including necessary form works, complete all as specified. |
| 58 | Preparation of new plastered wall surface and applying two coats of synthetic enamel paint over priming paint plaster coat complete all as specified and directed by Engineer-In-Charge. |
| 59 | Taking down steel tubing/ PVC 15mm bore and connections including cleaning for refixing or removing to stores complete all as specified and directed by Engineer - in – Charge. |
| 60 | All as per Srl Item No 58 here in before but 20mm bore all as specified and directed by Engineer - in - Charge. |
| 61 | Supplying and laying of CPVC pipes 20 mm outer diameter SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 62 | Supplying and laying of CPVC pipes 25 mm outer diameter SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 63 | S&F 25mm outer dia Brass TEE for CPVC pipe |
| 64 | S&F 25mm outer dia Brass elbow for CPVC pipe |
| 65 | S&F 25mm outer dia Tank Adaptor |
| 66 | S&F 25mm outer dia union |
| 67 | S&F 25mm outer dia Ball Valve |
| 68 | S&F in repair vitreous wash hand basin (flat back) white of size 550x400mm including one number chromium plated waste fittings, 32 mm dia, brass with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed to be mounted on platform/shelves, with & including 32 mm dia PVC waste pipe with connector, including cutting for and pinning in ends of brackets complete all as specified. |
| 69 | S&F in repairs vitreous china squating pan, 'Orissa' pattern, size 580x440 mm white, with integral foot rests, including 100mm cast iron 'P' or 'S' trap and 100mm cast iron sanitary connection socket to fit WC outlet including connection to trap, to flushing pipe, anti-syphonage pipe etc. complete including making good to floor complete all as specified and directed. |
| 70 | S&F in repairs white vitreous china wash down water closet pan (pedestal pattern) with PVC white seat cover with mild steel chromium plated or aluminised hinging device including connection to drowm pipe PVC connection and flushing pipe all as specified. |
| 71 | S&F in repair, Vitreous China urinals, half stall type , complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (inclusive of fixing supply pipe to flushing cistern, trap and waste pipe), but half stall urinal, etc complete all as specifed and directed. |
| 72 | S & F in repairs 10 litres capacity, PVC valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and suitable flush pipe PVC 32mm dia complete all as specified and directed. |
| 73 | S & F in repairs chromium plated shower rose 125mm size incl shower arm casted 190 mm long flat shape for wall mounted showers with flange incl fixing to steel pipe or union all as specified and directed by Engineer - in - Charge. |
| 74 | S&F in repair health faucet with double lock 1 meter brass plated stainless steel flexible hose and wall hook complete all as specified and directed |
| 75 | S & F in repairs PVC connection 15mm size with PTMT nuts of length 450mm all as specified and directed by Engineer - in – Charge. |
| 76 | S & F in repairs bib taps, long body cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down, screwed for 15 mm bore iron pipe or for brass ferrule complete all as specified. |
| 77 | S&F in repairs fancy type CP pillar tap single leaver basin mixer without popup waste system with 450 mm long braided hoses cat No DRC-37011B make Jaquar or equivalent out of makes spd in list of makes of any colour for basin 15 mm dia screwed down high pressure with long screwed shank sand fly nuts screwed for iron pipe fixed as in repairs complete all as specified and as directed. |
| 78 | S&F in repairs concealed stop cock type CP with long shank cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends of size 15mm bore. complete all as specified and directed. |
| 79 | S & F in repairs angle cock/stop valves, cast copper alloy, chromium plated, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for 15 mm bore iron pipe or for brass ferrule complete all as specified. |
| 80 | S & F in repairs 5-6mm thick beveled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial plywood and fixed with wooden plugs with chromium plated brass screws and cup washers all as specified and directed by Engineer - in - Charge . |
| 81 | S&F in repair SS grating doom 100mm dia size complete all as specified and directed. |
| 82 | Dismantling water tanks of capacity exceeding 500 and not exceeding 1000 ltrs all as specified and directed by Engineer - in - Charge. |
| 83 | S & F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I of capacity 1000 Litres all as specified and directed by Engineer - in - Charge . |
| 84 | M&L ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball with minimum weight 210 gm screwed for 20mm bore dia iron pipe supplied and fixed in repairs complete all as specified and as directed by Engineer-in-charge. |
| 85 | S&F in repair false ceiling with exposed GI system using “SILHOUETTE XL 15 mm (Nominal) designer Grid \\"Armstrong\\" white or Global white with black reveal and 600 x 600 x 15 mm thick prime fine fissured micro look white/coloured tiles (superfine 15mm/silhouette). Making necessary framework for AC ducting, if any and necessary cutouts for diffusers and light fittings, taping and finishing to proper line & level and incl dismantling old undervicable false ceilling complete all as per manufacturer’s instructions and as directed. |
| 86 | Supply and fixing of semi perforated false ceiling 12 mm thick with micro tegular edged at all height with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of size 595 x 595 mm of approved texture, design and pattern having moisutre content less than 2%, humidity resistance of 99%, NRC 0.60 to 0.85 as per IS 8225-1987, non combustible as per BS 476 (Part-4) 1970 and light code description unit code No 429 Sub Head 26. New Technologies and materials reflectance of 85% minimum to be laid in true horizontal level suspended on interlocking metal T -grid of hot dipped galvanised iron section of 0.33 mm thick ( galvanised @ 120 gms/ sqm including both sides) comprising of main T- runners of size 15x 32mm of length 3000mm, cross T of size 15 x32 mm of length 1200mm and secondary intermediate cross T of size 15 x 32 mm of length 600 mm to from grid module of size 600 x 600 mm, suspended form ceiliing using galvanised mild steel items (Galvanised @ 80 gm/sqm) i.e. 50 mm long, 8mm outer diameter M-6 dash fastners, 6mm dia fully threaded hanger rod upto 1000mm length and L shape level adjuster of size 85 x 25 x 2mm. galvanised iron perimeter wall angle of size 24 x 24 x 0.4 mm of length 3000 mm to be fixed on perimeter wall / partition with the help of plastic rawl plugs at 450 mm centre to centre and 40 mm long dry wall SS screws. The work shall be carried out as per specification, drawing and as per direction of the Engineer-in-Charge including dismantling existing asbestos sheet false ceiling textile coverings including frames (if any) and cover fillets complete all as specified and directed.NOTE : -Unit rate quoted against this item shall also include taking down and refixing the same of any electrical board, switch, sockets, light and fittings, fans etc after carrying out necessary relevant work and making good to match with existing surface effected for this area etc complete all as specified and directed. . |
| 87 | Supply and fixing fully perforated wall panelling at all heights with GRG (Glass fibre Reinforced Gypsum) panels/tiles of size 595x595mm of approved texture, design and patterns having moisture content less than 2% humidity resistance of 99% NRC 0.70 to 0.85 as per IS 8225:1097, Non combustible as per BS 476 (Part-4)-1970 and light reflectance of 75% to 85% (Minimum) comprising of a frame made from especially fabricated galvanized mild steel sheet 0.50 mm thick pressed section (galvanizing @ 120 gms per sqm including both sides) i.e vertical studs of size 48 x 34 x 36mm are placed at 600mm center to center in a floor and ceiling channel section of size 50 x 32mm fixed to the floor and soffit at 600mm center using 12mm dia, 50mm long wedge type expanded zinc alloy dash fastener with 10mm bolt. This same channel is then to be fixed in horizontal direction at 600mm center to centers so as to form a grid of 600x600mm. Glass wool of 50mm thickness is then to be inserted in the slots and finally GRG (Glass fibre Reinforced Gypsum) non-combustible panels/tiles are to be screw fixed with self-tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even grooveof 1mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing compound and fiber joint tape roll 50mm wide (90 mtr) roll and two coats of primer suitable for panelling as per manufacturer's specification and as per direction of Engineer-in-Charge completed all as specfied and as directed. |
| 88 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/Disintegrtated rock complete all as specified. |
| 89 | M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete, sub base complete all as specified. |
| 90 | M&L for reinforced concrete pipes 150 mm dia, class NP-2, laid and jointed complete with collars complete all as specified. |
| 91 | M&L cement concrete 1:3:6 type C-2 for 150 mm dia in bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested etc complete all as specified. |
| 92 | S&F SFRC manhole cover 75mm thick factory made with plain surface as per requirement including 75 X1.5 mm flat iron frame all around the cover complete all as specified. |
| 93 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick with soil etc complete all as specified. |
| 94 | Removing excavated material to distance not exc 50 metre and depositing where directed at a level n.exc 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-Charge |
| 95 | Demolition of cement concrete (unreinforced) of any description including cast-in-situ terrazzo (below or above ground level), not exc. 15 cm thickness, including removal of rubbish outside MoD land, complete all as specified. |
| 96 | M & L for 75 mm thick, Cement concrete type D-2, 1:4:8 (40mm graded aggregate), etc completed all as specified. |
| 97 | Providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved design & pattern as in footpath , parks , lawns,drive ways or light traffic parking etc. of required strength , thickness & size/shape, made by table vibratory method using PU mould , laid in required pattern over and including 25 mm thick compacted bed of fine sand , compacting and proper embedding/laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator,filling joints with sand andcutting of paver block as per required size and pattern,finishing and sweeping extra sand. |
| 98 | Chequered cement concrete tiles 30cm x 30cm x 25mm thick in floors / path set, jointed & pointed in neat cement slurry using grey cement and no pigment laid over and including 15mm thick screed bed in cement mortar (1:6) including necessary cutting as per site requirement complete all as specified. |
| 99 | M&L for PCC 1:2:4 Type B-1 (using 20mm stone crushed agg.) as in coping , rounded or chamfered on edges in any description. Complete all as specified |
| 100 | Excavation in post holes (or similar holes) each n. exc 0.5cum, getting out, returning filling in and ramming earth or brocken rubble mixed with earth arround in layers not exc 25cm watering and removing surplus soil to a distance n. exc 50m and making good surfaces etc complete all as specified |
| 101 | M&L Cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified. |
| 102 | M&L Cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate as in coping including necessary formwork complete all as specified. |
| 103 | Mild steel angle iron conforming to FE-290 Gde E-250 as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc. flat iron fillets (for securing wire mesh etc.) including all drilling, bolting or rivetting etc. and similar works and embedding in concrete and screwing etc. complete all as specified |
| 104 | Mild steel bolts (machine made) with screwed on end with hexagonal or square nuts and washer other end 5-10 mm dia of neck and exc 5 cm long but n exc 10 cm long complete all as specified. |
| 105 | Supply only chain link MS hot dipped galvanised coating fencing any size or type as complete all as specified. |
| 106 | Mild steel round bars 10mm dia and over cut to length, bent to shape required including bending spirally , hooking ends and binding with mild steel wire or securing with clips or welded to MS angle conforming to Fe-410 Gde E-250 quality- A etc complete all as specified. |
| 107 | Dismantling of old chain link fencing of any description of weight n exc 4.0 kg/sqm from existing fencing fixed with steel or concrete posts complete all as specified. |
| 108 | Fixing only chain link fencing including line wires any mesh, size and type to any type of standards, rail, straining bolts etc including provision of binding wire etc complete all as specified. |
| 109 | Dismantling posts or struts (wood, steel or RCC) any section including taking out embedded portion (posts embedded in concrete, brick work etc.) and making good the disturbed ground complete all as specified. |
| 110 | Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings withand provision of galvanised mild steel wire, staples or steel pins etc IN REPLACEMENT as directed complete all as specified. |
| 111 | Preparing steel and iron surfaces (new) of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer complete all as specified. |
| 112 | E&M ITEMS |
| 113 | Taking down old point wiring complete for light/fan/socket(5/15 Amps) bell point etc complete with all light fittings accessories, such as switch sockets 5/15 Amps ceiling rose etc including making good to the disturbed surface to match with the existing complete all as specified and directed by Engineer-in-Charge. |
| 114 | Taking down existing ceiling fans any size in position and re-fixing the same after B/R work including painting of the same with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and writing MES Number in black paint with skilled painter, with and including providing three core flexible copper cable for connection from ceiling rose/connector complete all as specified and directed by Engr-in-Charge. |
| 115 | Taking down carefully exsiting ceiling fan /Exhaust fan of any size, sealing cable end, dismantling blades and removing fan and blades and kept aside and deposited to MES yard. |
| 116 | Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. |
| 117 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed. |
| 118 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :- |
| 119 | One light point control by one switch |
| 120 | One ceiling fan/exhaust fan control by one switch |
| 121 | One 3 pin socket outlet, 5 Amps independent |
| 122 | One 3 pin 5 amps socket outlet on the same board with other switches |
| 123 | One bell/buzzer point contolled by one push button independent |
| 124 | ditto as per item No. 6 above but wire 2.5 sq mm cable for switch socket outlet 3 pin 15 Amps with 2.5 sq mm as earth continuity conductor complete all as specified and directed. (FOR 15 Amps socket point) |
| 125 | ditto as per item No. 118 above but wire 4.0 sq mm cable for switch socket outlet 3 pin 15 Amps with 2.5. sq mm as earth continuity conductor complete all as specified and directed. (FOR geyser/AC point) |
| 126 | S & F Modular switch one way 6 Amps, single pole 240 volts, ISI marked complete all as specified and directed. |
| 127 | Supply and fix ceiling rose three terminal surface bakelite 65/25 mm dia complete all as specified and directed. |
| 128 | S & F Modular socket outlet 2 in 1, 3 pin, 6 Amps complete all as specified and directed. |
| 129 | S&F Modular socket outlet 2 in 1, 3 pin, 6 and 16 Amps flush type, 240 Volts, ISI marked complete all as specified and directed. |
| 130 | S&F Modular switch piano, flush type single pole 16 Amps |
| 131 | S&F call bell multi music type, AC 230 Volts, single pole complete all as specified and directed. |
| 132 | Supply and fixing Modular bell push flush type 6 Amps, single pole, ISI marked complete all as specified and directed. |
| 133 | Supply and fixing LED lights fitting 1x 25W, 220V, AC decorative box type with driver, ultra slim polycarbonate LED lighting fixture with high lumen output, environmental friendly, energy efficient ready to use pack with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 134 | S & F LED light fitting 1 x 9 W/ 1 x 10 W bulkhead luminaired including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. Make : Havells/Philips/Crompton/Wipro |
| 135 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) |
| 136 | Supply and fixing modular stepped type electronic fan regulator flush type |
| 137 | Supply and fix in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed. |
| 138 | Supply and Fix in repairs flush mounting factory made Vertical FP DB, IP-43 Protection -IK 09 with metal double door with 200 Amps rated copper busbar with 2 neutral bar, earth bar and cables ties for cable management fully insulated bus bar with set of wires and door earthing with provision of sapce for 100-125 amps MCCB as incomer and SPN/TP MCBs as out going, 4 way (Optium 1+12 Module) including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour complete all as specified and directed by Engr-in-Charge. |
| 139 | S & F for sheet metal enclosure MCB DB SPN 12 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 140 | S&F MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA |
| 141 | S&F MCCB 3 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA |
| 142 | S&F MCCB 3 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 25 KA |
| 143 | Supply and fixing 240V 10KA 'B' SP 6 to 32 Amps curve miniature circuit breake (MCB) and current carrying capacity in the DB complete with connection testing and commissioning |
| 144 | Supply and fixing 32 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of two poles and current carrying capacity in the MCB DB complete with connection testing and commissioning |
| 145 | Supply and fix heavy duty single phase, steel body exhaust fan 450 mm sweep, 900 RPM complete with shutter and louvers and exhaust fan shall be fixed with suitable size of buzzer bolt/hold fastener as approved by Engr-in-charge complete all as specified and directed. |
| 146 | S & F in repair sub main wiring for circuit of size 6 sq mm 2 core (FRLS) alongwith earth wire of 6 sq mm single core of FRLS PVC insulated unsheathed cable, 1100 volts grade with multistranded copper conductor including PVC conduit (conealed wiring) of suitable size complete all as specified and directed by Engr-in-Charge. (FOR SPN DB's & energy meter) |
| 147 | S & F in repair sub main wiring for circuit of size 4 sq mm 2 core (FRLS) alongwith earth wire of 2.5 sq mm single core of FRLS PVC insulated unsheathed cable, 1100 volts grade with multistranded copper conductor including PVC conduit (conealed wiring) of suitable size complete all as specified and directed by Engr-in-Charge. (FOR SPN DB's & energy meter) |
| 148 | Supply and fixing in repair LED bldg security light fitting 35 watts 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including suitable size of GI bracket for mounting of security light to be bend as required shape, pipe bracket shall be made as per direction and site requirement and suitable size 02 Nos MS clamps and nuts and bolts. Make : Havells/Philips/Wirpo |
| 149 | S & F for Modular type TV Socket out let complete all as specified and as directed. |
| 150 | S & F for PVC non-metallic rigid conduit ISI marked heavy duty white/ Ivory colour and its accessories heavy duty ISI marked of size 20 mm dia for telephone and TV connections including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed. |
| 151 | Supply and fix and testing for anti suicide fan road 12 inch if the load on fan exceeds 22 kg , than the smartm rod / pice opens from its centere and spring in the pipe expands. Thus any one trying to hang from fan comes down safely complete all as specified and directed. |
| 152 | Supply and laying in repair and testing cable XLPE insulated, screned, PVC bedded galvanized steel strip or wire amoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core |
| 153 | Supply laying and jointing GI pipe 'light grade' 40 mm bore in trenches/under floors or roads/ along poles/ on wall incl clamps for protection of cables incl fittings complete all as specified and directed. |
| 154 | M&L for earthing to LT panel board/TPN DB with mild steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) connected to galvanised earth lead wire 4.0 mm dia by means of galvanised iron nuts, bolts and washer, earth lead connected to eqpt as directed, earth plate surrounded with adequate quantity of charcoal dust mixed with common salt to a packed thickness of 15 cm all around the plate including necessary earth work, PCC chamber and reinforced PCC cover made by PCC 1:3:6 type C-1 as in pit chamber and RCC pit cover 50 mm thick precast RCC 1:2:4 type B-1 duly reinforced with 6mm dia MS bar at 150mm c/c both ways with 10 mm dia MS round bar as handle, 20 mm bore GI pipe medium grade for watering and 15 mm dia GI pipe light grade for protection of earth lead up to 7.5 mtr with funnel, wire mesh etc with and including testing complete all as specified and as shown in electrical plate No 3 of MES sch Part I. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail