| Sl. No. | Item Description |
| 1 | Building Works incl Internal Water Supply Works |
| 2 | Dismantling PVC sheet/ wooven flooring incl cleaning the surfaces, complete all as specified and directed by Engineer - in - charge . |
| 3 | M&L for synthetic wooven flooring carpet weight 1.5 kg/sm fixed with approved rubber base adhesive as in floors, complete all as specified and directed by Engineer - in - charge . |
| 4 | S&F in repair 2.00mm thick PVC tiles/ sheets, laminated plain coloured, marbled mosaic or mottled finish, laid with approved rubber based adhesive in floors and skirting etc., complete all as specified and directed by Engineer - in - charge . |
| 5 | Demolishing cement concrete of any discription by manually or mechanical means including disposal of material within 50 metres lead, complete all as specified and directed by Engineer - in - charge . |
| 6 | M&L for PCC type 1:3:6 ( using 20 mm nominal size stone aggregate ) as in plinth protection, complete all as specified and directed by Engineer - in - charge . |
| 7 | M&L for providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry, complete all as specified and directed by Engineer - in - charge . |
| 8 | Plain cement concrete 1:7:12 mix, type E-2 (using 40mm graded Brick aggregate) as in filling of sunken portion complete all as specified and directed. |
| 9 | Providing 40 mm dia GI pipe medium grade spouts 60 cm long, complete all as specified and directed. |
| 10 | PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate 25mm thick as in bedding layer under floor tiles etc complete all as specified and directed. |
| 11 | Dismantling tile work of thickness 10 mm to 25 mm, in floors/roofs/Wall laid in cement mortar, including stacking material within 50 metres lead, complete all as specified and directed by Engineer - in - charge . |
| 12 | M&L for coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exce 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20mm thick screed bed in cement mortar 1:4, complete all as specified and directed by Engineer - in - charge . |
| 13 | M&L for Glazed ceramic tiles in vertical surface 450x300x7-8mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick backing coat of cement mortar in 1:3, complete all as specified and directed by Engineer - in - charge . |
| 14 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead, complete all as specified and directed by Engineer - in - charge . |
| 15 | M&L for polished Granite stone flooring of colour Black, Cherry/Ruby Red or approved by AO in required design and patterns, in linear as well as curvilinear portions of the building all with 18-20mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc., complete all as specified and directed by Engineer - in - charge . |
| 16 | Dismantling wooden boardings of thickness above 10 mm up to 25 mm in lining of walls and partitions, excluding supporting members, including stacking within 50 metres lead and, complete all as specified and directed by Engineer - in - charge . |
| 17 | S & F of 18mm thick UV coating, HDHMR board exterior grade, including acrylic high gloss sheet of 3mm thick over HDHMR board,anti fungal,moisture resistence,anti borer, as per IS 14587 for frame and shutter for kitchen cabinets/Cupboards etc.flat pressed hdhmr boards 15380: 2003 marked, having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete all as specified and directed by Engg-in-charge. NOTE:- Sample as approved by AGE (I) . Make:-Action tessa/Greenply/ Century |
| 18 | Providing and fixing 125 mm aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc, complete all as specified and directed by Engineer - in - charge . |
| 19 | Taking out doors, windows and clerestory window shutters (steel or wood) of area up to 3 sq. metres and below including stacking within 50 metres lead complete |
| 20 | Providing and fixing factory made single extruded WPC Size 65 x 125 mm(Wood Polymer Composite) solid door/window/clerestory windows & desertory other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made, complete all as specified and directed by Engineer - in - charge . |
| 21 | Providing and fixing 35 mm thick factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed by Engineer - in - charge . (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 22 | S&F 125x60mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges lock strike plate etc. , complete all as specified and directed by Engineer - in - charge . |
| 23 | S&F 30 mm thick flush shutters , solid core construction with block board core and plywood face panels commercial type both side with lipping/frame to match, complete all as specified and directed by Engineer - in - charge . |
| 24 | S&F for 2nd class hard wood 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc., sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a), supplied and fitted to chowkats, complete all as specified and directed by Engineer-in-Charge. |
| 25 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC Sheet & edges will be painted to match with prelam sheet reinforced with M.S Square tube, in opening , complete all as specified and directed by Engineer - in - charge . |
| 26 | S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & wood grain printed PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of wood grain printed PVC sheet to be fitted in the M.S frame welded/ sealed to the 5mm thick x15mm wide decorative PVC beading of 10mm x 10mm (90 degree) , & joined together with solvent cement, in the frame at site, complete all as specified and directed by Engineer - in - charge . |
| 27 | S&F for 200mm Stainless steel, barrel tower bolts of extruded section and fixed complete all as specified and directed by Engineer-in-Charge. |
| 28 | S&F for 300mm Stainless steel sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed by Engineer-in-Charge. |
| 29 | S&F 100 mm Butt hinges, type C-21, extruded aluminium alloy, with stainless steel hinge pin, anodised and fixed, complete all as specified and directed by Engineer - in - charge . |
| 30 | Providing and fixing Twin rubber stopper aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc., complete all as specified and directed by Engineer - in - charge . |
| 31 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron), complete all as specified and directed by Engineer - in - charge . |
| 32 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not lessthan 10kg/sqm), complete all as specified and directed by Engineer - in - charge . |
| 33 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, and min wt 3kg/sqm with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as specified and directed by Engineer - in - charge . |
| 34 | M&l for fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4 mm wide aperture with matching wood beading in repairs, complete all as specified and directed by Engineer - in - charge . |
| 35 | M&L for renewing glass panes, with putty and nails wherever necessary including racking out the old putty float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm in repairs, complete all as specified and directed by Engineer - in - charge . |
| 36 | Dismantling 15 mm to 40 mm nominal bore G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead, complete all as specified and directed by Engineer - in - charge . |
| 37 | S&F in repairs 3 layer PP-R (Poly propylene Random copolymer) pipes of PN - 16 Pipe, 20mm OD (SDR-7.4) confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases for concealed work and making good the same including testing of joints, complete all as specified and directed by Engineer - in - charge . |
| 38 | S&F in repairs 3 layer PP-R (Poly propylene Random copolymer) pipes of PN - 16 Pipe, 25mm OD (SDR-7.4) confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases for concealed work and making good the same including testing of joints, complete all as specified and directed by Engineer - in - charge . |
| 39 | S&F in repairs 150 mm diameter C.P. brass shower rose with 15 or 20 mm inlet , complete all as specified and directed by Engineer - in - charge . |
| 40 | S&F in repairs 15 mm bore CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge, complete all as specified and directed by Engineer - in - charge . |
| 41 | S&F in repairs White Vitreous China Wash basin of size 550x400 mm with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required, complete all as specified and directed by Engineer - in - charge . |
| 42 | S&F in repairs stainles steel towel rail of 600 mm long with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour, complete all as specified and directed by Engineer - in - charge . |
| 43 | S&F in repairs white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid approved by EIC, complete all as specified and directed by Engineer - in - charge . |
| 44 | S&F in repair sunplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 45 cm length approved by EIC, complete all as specified and directed by Engineer - in - charge . |
| 45 | S&F in repairs 32 mm dia Flexible P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings approved by EIC , complete all as specified and directed by Engineer - in - charge . |
| 46 | S&F in repair stainless steel plate rack of size 90x60x25 cm made with not less than 1.00 mm thick sheet, complete all as specified and directed by Engineer - in - charge . |
| 47 | S&F in repairs 100mm dia Circular type CP grating with or without hole of approved quality and colour approved by EIC, complete all as specified and directed by Engineer - in - charge . |
| 48 | S&F in repairs 15mm bore C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931, complete all as specified and directed by Engineer - in - charge . |
| 49 | S&F in repairs 15mm bore C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931, complete all as specified and directed by Engineer - in - charge . |
| 50 | S&F in repairs 15mm bore C.P. brass bib cock of approved quality conforming to IS:8931, complete all as specified and directed by Engineer - in - charge . |
| 51 | S&F in repairs 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers approved by EIC, complete all as specified and directed by Engineer - in - charge . |
| 52 | S&F in repairs 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., approved by EIC, complete all as specified and directed by Engineer - in - charge . |
| 53 | S&F in repairs stainless soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms, complete all as specified and directed by Engineer - in - charge . |
| 54 | S&F in repairs 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by AO, complete all as specified and directed by Engineer - in - charge . |
| 55 | S&F in repairs C.P. brass toilet paper holderapproved by AO, complete all as specified and directed by Engineer - in - charge . |
| 56 | S&F in repairs Stainless Steel A ISI 304 (18/8) kitchen sink of size 510x1040 mm bowl depth 250 mm with drainboard as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required, complete all as specified and directed by Engineer - in - charge . |
| 57 | S& F in repair 32 mm Waste fittings, brass, chromium plated for basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed approved by EIC, complete all as specified and directed by Engineer - in - charge . |
| 58 | S&F in repair 40 mm Waste fittings, brass, chromium plated for sinks, with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed approved by EIC, complete all as specified and directed by Engineer - in - charge . |
| 59 | Providing and fixing in repairs chromium plated brass curtain rod 25 mm dia having wall thickness of 1.25 mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary, complete all as specified and directed by Engineer - in - charge . |
| 60 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead 100 mm dia pipe, complete all as specified and directed by Engineer - in - charge . |
| 61 | Supply and fixing PVC (SWR) pipes single socketed in any length with rubber ring joints 110 mm dia laid in trenches of fixed to walls, complete all as specified and directed by Engineer-In- Charge. |
| 62 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead 75 to 80 mm dia pipe, complete all as specified and directed by Engineer - in - charge . |
| 63 | Supply and fixing PVC (SWR) pipes single socketed in any length with rubber ring joints 75 mm dia laid in trenches or fixed to walls, complete all as specified and directed by Engineer-In- Charge. |
| 64 | Providing and fixing on wall face unplasticised - PVC moulded bends any radius of 110 mm bore for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, complete all as specified and directed by Engineer - in - charge . |
| 65 | Providing and fixing on wall face unplasticised - PVC moulded bends any radius of 75 mm bore for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, complete all as specified and directed by Engineer - in - charge . |
| 66 | S&F in repair 75 mm dia PVC floor trap plain with grating including jointing with solvent cement , complete all as specified and directed by Engineer - in - charge . |
| 67 | S&F in repair 110 mm dia PVC P/S trap (As per Requirment) incl fixing of trap using PCC 1:2:4(20 mm Garded Stone aggregates) including jointing with solvent cement complete all as specified. |
| 68 | Providing and fixing in repairs 100 mm sand cast Iron grating for gully trap complete all as specified. |
| 69 | Demolishing brick work by manually or mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead , complete all as specified and directed by Engineer - in - charge . |
| 70 | M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 , complete all as specified and directed by Engineer - in - charge . |
| 71 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead, complete all as specified and directed by Engineer - in - charge . |
| 72 | Providing & fixing inter locking metal grid (snap grid for false ceiling) of size 605 mm x 605 mm in true horizontal level, hot dipped galvanized steel sections (galvanized @ 120 grams/sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24 mm X 38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200 mm x 600 mm and secondary cross “T” of length 600 mm and size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200 mm X 600 mm panel to form grids of 600 mm X 600 mm and wall angle of size 24 mm X 24 mm X 0.4 mm. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 mm X 37 mm X 25 mm X 1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 mm X 30 mm X 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, 8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process, complete all as specified and directed by Engineer - in - charge . |
| 73 | M& L for pastered or unplastred old surface walls with two coat of Acrylic Smooth exterior paint of required shade over and incl a coat of primer on existing cement paint surface including scaffolding upto 8mtr, trestles, ladders, cradles and necessary safety measuresetc., complete all as specified and directed by Engineer - in - charge . |
| 74 | Removing dry or oil bound distemper, water proofing cement paintand the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc., complete all as specified and directed by Engineer - in - charge . |
| 75 | M&L for preparing of old plastered or un plastered surfaces applying two coat of distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade and including scaffolding, trestles, ladders, cradles and necessary safety measures, complete all as specified and directed by Engineer - in - charge . |
| 76 | M&L for white wall carfe putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth, complete all as specified and directed by Engineer - in - charge . |
| 77 | M & L for preparation of old or new painted surfaces of wooden work over 10 cm width or girth and applying one coat of synthetic enamel paint (ordinary tint), complete all as specified and directed by Engineer - in - charge . |
| 78 | M & L for preparation of old or new painted surfaces of steel and iron work over 10 cm width or girth and applying one coat of synthetic enamel (ordinary tint) paint, complete all as specified and directed by Engineer - in - charge . |
| 79 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead, complete all as specified and directed by Engineer - in - charge . |
| 80 | M&L for rendering 15 mm thick on fair faces of brick/stone work or concrete surfaces cement mortar 1:6 for rendering is to be finished even and smooth (without using extra lime or cement and walls etc, complete all as specified and directed by Engineer - in - charge . |
| 81 | M&L for rendering 15 mm thick on fair faces of brick/stone work or concrete surfaces cement mortar 1:4 for rendering is to be finished even and smooth (without using extra lime or cement and walls etc, complete all as specified and directed by Engineer - in - charge . |
| 82 | M&L for rendering 5 mm thick on fair faces of brick work/stone or concrete surfaces cement mortar 1:3 rendering is to be finished even and smooth (without using extra cement for roof, soffits of Chajjas, balconies and walls etc., complete all as specified and directed by Engineer - in - charge . |
| 83 | Raking out joints /pointing built in cement mortar to random rubble masonary of wall surface, channels, roofs etc., complete all as specified and directed by Engineer - in - charge . |
| 84 | M&L for raised pointing using cement mortar 1:4 to random rubble masonary wall surface, channels, roofs etc, complete all as specified and directed by Engineer - in - charge . |
| 85 | M& L for pastered or unplastred New surface walls with Acrylic Smooth exterior paint of required shade two coats over incl a coat of primer on existing cement paint surface including scaffolding upto 8mtr, trestles, ladders, cradles and necessary safety measuresetc., complete all as specified and directed by Engineer - in - charge . |
| 86 | M&L for two coats of acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brandon walls on newly plastered surfaces over 1 mm thickness wall care putty including preparation of surfaces by brooming or by steel wire brushing, complete all as specified and directed by Engineer - in - charge . |
| 87 | M&L in repair for Chequred Cement concrete coloured tiles glossy finish, rubber moulded with grey cement and pigments 20cm x 20cm x 25mm thick, machine pressed, set jointed and pointed in neat cement slurry in floors, with and including 20 mm thick screed bed in CM 1:4, complete all as specified and directed by Engineer - in - charge . |
| 88 | Sewage Disposal Works |
| 89 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means for any type of soil as in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm diaincluding dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m., complete all as specified and directed by Engineer - in - charge . |
| 90 | Dismantling of old S.W. pipes up to 150mm diameter including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps, complete all as specified and directed by Engineer - in - charge . |
| 91 | Providing and laying cement concrete 1:5:10 using 40 mm nominal size graded stone aggregate as in haunches of S.W pipe of 150 mm diameter including bed concrete as per standard design, complete all as specified and directed by Engineer - in - charge . |
| 92 | Providing, laying and jointing glazed stone ware pipes 150 mm dia class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 including testing of joints etc. , complete all as specified and directed by Engineer - in - charge . |
| 93 | Returning filling in including spreading leveling watering and well ramming in layers not exc 25 cm in soft/loose soil, complete all as specified and directed by Engineer - in - charge . |
| 94 | Demolition of exisiting damaged stone/Brick/ Concrete Block masonary built in cement mortar including all quoins, arches, pillars etc., complete all as specified and directed by Engineer-In- Charge. |
| 95 | M&L for constructing brick masonry manhole using cement mortar 1:4 with R.C.C. top slab with 1:1.5:3 mix ( graded stone aggregate 20 mm nominal size, foundation concrete 1:4:8 mix graded stone aggregate 40 mm nominal size, inside plastering 12 mm thick with cement mortar 1:3 finished with floating coat of neat cement and making channels in cement concrete 1:2:4 graded stone aggregate 20 mm nominal size finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 and incl demolition in old manholes and required earth work(Incl Excavation, retuirning filling and disposes of remaining material), complete all as specified and directed by Engineer - in - charge . |
| 96 | M&L for constructing brick masonry manhole in cement mortar 1:4 with R.C.C. top slab with 1:1.5:3 mix graded stone aggregate 20 mm nominal size, foundation concrete 1:4:8 mix 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 finished with floating coat of neat cement and making channels in cement concrete 1:2:4 graded stone aggregate 20 mm nominal size finished with a floating coat of neat cement complete as per standard design : Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) With common burnt clay F.P.S. (non modular)bricks of class designation 7.5 and demolition in old manholes and required earth work (Incl Excavation, retuirning filling and disposes of remaining material) complete all as specified |
| 97 | M&L for RCC Septic tank conventional type 50 user designed to carry sewage and sullage water, incl excavation in any type of soil required as per Drg, PCC below foundation as per Drg, RCC M-30 Design Mix (Whatever Showing in Drg ) (in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete all as per Drg No. STD 1320(C) 1/3 to 3/3 |
| 98 | M&L for making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 complete all as per Drg NoSTD 1173 (C) Sheet 1R/2 to 2R/2 and directed by Engr-in-Charge. |
| 99 | Internal Electric Works |
| 100 | Taking down carefully the old u/s Aluminium/ Copper point wiring (light, fan, socket or power) complete fitting such as switches, ceiling roses, pendants, sockets, regulators, etc and making good disturbed surfaces of walls including necessary touch up with the adjoining surface of disturbed area ie with OBD/colour wash/white wash as the existing finish, complete all as specified and directed by Engineer-In- Charge. |
| 101 | M&L for point wiring for One light /fan point controlled by one way switch, complete with single core multi strand copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 Volts grade electrical cable in and including concealed/Surface PVC conduit/casing caping medium grade and Modular sunken pressed steel terminal box 2 mm thick required size including modular plate and modular flush box in different module with all accessories including 1.5 Sqmm single core with multi strand copper conductor PVC unsheathed cable earth and connected to earth dolly , complete all as specified and directed by Engineer-In- Charge. Note 01:- the rate is inclusive of cutting/chasing and making good the disturbed surface with CM 1:3 and the same surface finishes with the adjoining surface of disturbed area with OBD/colour wash/white wash |
| 102 | M&L for point wiring for one 3 pin socket outlet 5 amps independent board, complete with single core multi strand copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 Volts grade electrical cable in and including concealed/Surface PVC conduit/casing caping medium grade and Modular sunken pressed steel terminal box 2 mm thick required size including modular plate and modular flush box in different module with all accessories including 1.5 Sqmm single core with multi strand copper conductor PVC unsheathed cable earth and connected to earth dolly , complete all as specified and directed by Engineer-In- Charge.Note 01:- the rate is inclusive of cutting/chasing and making good the disturbed surface with CM 1:3 and the same surface finishes with the adjoining surface of disturbed area with OBD/colour wash/white wash complete. |
| 103 | M&L for point wiring for one 3 pin socket outlet 5 amps point on same board , complete with single core multi strand copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 Volts grade electrical cable in and including concealed/Surface PVC conduit/casing caping medium grade and Modular sunken pressed steel terminal box 2 mm thick required size including modular plate and modular flush box in different module with all accessories including 1.5 Sqmm single core with multi strand copper conductor PVC unsheathed cable earth and connected to earth dolly, complete all as specified and directed by Engineer-In- Charge.Note 01:- the rate is inclusive of cutting/chasing and making good the disturbed surface with CM 1:3 and the same surface finishes with the adjoining surface of disturbed area with OBD/colour wash/white wash complete. |
| 104 | M&L for point wiring for One 3 pin socket outlet, 15 amps on independent board with cable 2.5 Sqmm for main current and 2.5 sqmm as earth wire as power point. and including concealed/Surface PVC conduit/casing caping medium grade and Modular sunken pressed steel terminal box 2 mm thick required size including modular plate and modular flush box in different module with all accessories including, complete all as specified and directed by Engineer-In- Charge.Note 01:- the rate is inclusive of cutting/chasing and making good the disturbed surface with CM 1:3 and the same surface finishes with the adjoining surface of disturbed area with OBD/colour wash/white wash complete. |
| 105 | M&L for point wiring for One 3 pin socket outlet, 15 amps on independent board with cable 4 Sqmm for main current and 4 sqmm as earth wire as power point and including concealed/Surface PVC conduit/casing caping medium grade and Modular sunken pressed steel terminal box 2 mm thick required size including modular plate and modular flush box in different module with all accessories including, complete all as specified and directed by Engineer-In- Charge.Note 01:- the rate is inclusive of cutting/chasing and making good the disturbed surface with CM 1:3 and the same surface finishes with the adjoining surface of disturbed area with OBD/colour wash/white wash complete. |
| 106 | M&L for point wiring for One 3 pin socket outlet, 16 amps on independent board with cable 2.5 Sqmm for main current and 2.5 sqmm as earth wire as power point. and including concealed/Surface PVC conduit/casing caping medium grade and Modular sunken pressed steel terminal box 2 mm thick required size including modular plate and modular flush box in different module with all accessories including, complete all as specified and directed by Engineer-In- Charge.Note 01:- the rate is inclusive of cutting/chasing and making good the disturbed surface with CM 1:3 and the same surface finishes with the adjoining surface of disturbed area with OBD/colour wash/white wash complete. |
| 107 | M&L for point wiring for One bell / buzzer point controlled by one bell push with cable 2.5 Sqmm for main current and 2.5 sqmm as earth wire as power point. and including concealed/Surface PVC conduit/casing caping medium grade and Modular sunken pressed steel terminal box 2 mm thick required size including modular plate and modular flush box in different module with all accessories including, complete all as specified and directed by Engineer-In- Charge.Note 01:- the rate is inclusive of cutting/chasing and making good the disturbed surface with CM 1:3 and the same surface finishes with the adjoining surface of disturbed area with OBD/colour wash/white wash complete. |
| 108 | S&F in replacement switch 6 Amps modular type,1M with red indication single pole one way, complete all as specified and directed by Engineer-In- Charge. Make : Anchor/Legrand/crabtree |
| 109 | S&F in replacement switch 6 Amps modular type,1M with red indication single pole two way, complete all as specified and directed by Engineer-In- Charge. Make : Anchor/Legrand/crabtree |
| 110 | S&F in replacement socket 6 Amps,2/3 pin combined modular type 2M ,shuttered type, complete all as specified and directed by Engineer-In- Charge. Make : Anchor/Legrand/crabtree |
| 111 | S&F in replacement switch 16 Amps, modular type 1M with red indication single pole one way, complete all as specified and directed by Engineer-In- Charge.Make : Anchor/Legrand/crabtree |
| 112 | S&F in replacement socket 6/16 Amps 2/3 pin combined modular type 2M,shuttered type , complete all as specified and directed by Engineer-In- Charge. Make : Anchor/Legrand/crabtree |
| 113 | S&F of Switch modular type 2M, 16 Amp with light indicator, complete all as specified and directed by Engineer-In- Charge.(i) Electric switch for geyser of 16 Amps shall be provided on main switch board of the bathroom and socket outlet shall be provided near the geyser and will be measured as 16 Amps power point wiring against item No 104 here-in-before. |
| 114 | S&F in replacement Bell Push 6 Amps modular type,1M with single pole one way, complete all as specified and directed by Engineer-In- Charge. Make : Anchor/Legrand/crabtree |
| 115 | S&F in replacement ceiling rose surface Bakelite 60x 25 mm two to three terminals, complete all as specified and directed by Engineer-In- Charge. |
| 116 | S&F of bell Ding dong type 230 volts single phase, complete all as specified and directed by Engineer-In- Charge. |
| 117 | S&F surface mounting LED Integrated Aluminium Batten luminarie Polycarbonate co-extusion tube for not less than 18W LED light(4 ft) housing. Fixture should have minimum efficacy at system level >=120 lumens/Watt, life of fixture not less than 50K Hrs,Ripple<5%,UGR<19,minimum Surge protection level of 4 KV, CCT 4000-6500K with same lumens/w CRI>80, PF>0.95 THD<10% @ 240v Ac. An operating voltage Range of 140-270V including all connection upto ceiling rose , complete all as specified and directed by Engineer-In- Charge. |
| 118 | S&F surface mounting LED Integrated Aluminium Batten luminarie Polycarbonate co-extusion tube for not less than 9W LED light(2ft) housing. Fixture should have minimum efficacy at system level >=120 lumens/Watt, life of fixture not less than 50K Hrs,Ripple<5%,UGR<19,minimum Surge protection level of 4 KV, CCT 4000-6500K with same lumens/w CRI>80, PF>0.95 THD<10% @ 240v Ac. An operating voltage Range of 140-270V including all connection upto ceiling rose , complete all as specified and directed by Engineer-In- Charge. |
| 119 | S &F for wall light ftting complete with LED bulb/lamp of 7/9 Watts Cool/warm white Daylight, complete all as specified and directed by Engineer-In- Charge. |
| 120 | S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed by Engineer-In- Charge. |
| 121 | Supply,installation,testing & comissioning of 300 mm sqweep exhaust fan,having 1400 rpm speed,90 watt,1600 CMH steel body AC single Phase. 230V with, blades, and frame and louvers including making of holes of suitable size if reqd. & taking down old exhaust fan and depositing to MES store yard, complete all as specified and directed by Engineer-In- Charge. |
| 122 | S&F of Metal exhaust fan 225 mm size suitable for 240V, 50 Hz single phase AC supply with, blades, and frame and louvers including nut, washer,ceiling rose etc complete and necessary electrical connection from ceiling rose to fan connecter with three core sheathed wire of required length including making of holes of suitable size if reqd & taking down old exhaust fan and depositing to MES store yard, complete all as specified and directed by Engineer-In- Charge. |
| 123 | S&F of Hot water storage(Geyser)25 Ltrs capacity,BEE 5 star rated,vertical type with suitable size of fastner and incl provision copper element corrosion resistance antiscaling magnesium anode, having adjustable knob for temperature control and inner tank material of superior glass lined tank and outer body material ABS with high pressure with standing capacity upto 8 bar presuure, having heating element 2 KW and minimum two year warranty on product, minimum 3 years warranty on heating element, complete all as specified and directed by Engineer-In- Charge. |
| 124 | M&L in repair of submain wiring with PVC insulated unsheathed copper conductor multi stranded FRLS type 1100V grade 2 x 6 sqmm complete drawn in new PVC concealed conduit and its accessories along with 1x 6 sqmm PVC insulated unsheathed copper conductor multi stranded FRLS type cable for continuous earth wire and duly connected to common earth dolly including taking out of old Unsv submain wiring, complete all as specified and directed by Engineer-In- Charge.Make:-RR/Polycab/Havells |
| 125 | Supply & Fixing in replacement sheet metal enclousure for DB's where MCB's to be used Single pole and Neutral 8 way ,240 volts, double door bus bar neutral link,earth bar and din rail, complete all as specified and directed by Engineer-In- Charge. |
| 126 | S&F 4 way(4+12) Double door, surface/recess mounting,vertical type,415 V,TPN MCB distribution board of sheet steel,dust protected,duly powder painted,inclusive of 200 A tinned copper bus bar,common neutral link,earth bar ,din bar for mounting MCBs(but without MCBs and incomer) as required, complete all as specified and directed by Engineer-In- Charge. |
| 127 | S&F 5A To 32A rating,240/415V,\\"C\\" curve MCB SP suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required, complete all as specified and directed by Engineer-In- Charge. |
| 128 | S&F 40A rating,240/415V,\\"C\\" curve MCB SPN suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required, complete all as specified and directed by Engineer-In- Charge. |
| 129 | S&F 100A rating,240/415V,\\"C\\" curve MCB TPN suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required, complete all as specified and directed by Engineer-In- Charge. |
| 130 | M&L in replacement of earthing complete with galvanised steel earth plate 600X600X6 mm thick buried directly in ground (earth pit not les than 2.25 M deep below GL with top edge of plate not less than 1.50 m below GL) connected with GI earth lead wire 4.0 mm as earthing leads by means of bolts, nuts, check nuts and washers all joints as shown on drawings and including excavation, earth work. GI pipe light grade 15 mm bore for protection of GI earth wire from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt PCC (1:2:4) type B1chamber and MS angle iron frame of 40mmx40mm x3 mmand RCC cover 40 mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No 3 of SSR Part -I and conected to earth test point including testing, complete all as specified and directed by Engineer-In- Charge. |
| 131 | External Electric Works |
| 132 | M & L for laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sqmm x 3.5 core, complete all as specified and directed by Engineer-In- Charge. |
| 133 | M & L for laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm x 4 cor, complete all as specified and directed by Engineer-In- Charge. |
| 134 | Excavation in trenches in hard/dense soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables, complete all as specified and directed by Engineer-In- Charge. |
| 135 | Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required, complete all as specified and directed by Engineer-In- Charge. |
| 136 | Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed by Engineer-In- Charge. |
| 137 | M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable, complete all as specified and directed by Engineer-In- Charge. |
| 138 | Supply and laying sub class ‘B’ bricks well burnt for cable protections laid flat with length equal to width of brick over cable perpendicular to length of cable, complete all as specified and directed by Engineer-In- Charge. |
| 139 | Supply, laying and testing galvanised steel tube (GI) light grade of size 40 mm (1.5\\") bore fixed to walls and ceilings or laid in trenches, complete all as specified and directed by Engineer-In- Charge.Make :- Jindal/Surya/Prakash.Note:-The rate is inclusive of PCC work and making good the disturbed surface of ceiling ,wall, road etc. |
| 140 | Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanised iron strip 25x4 mm by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 5 of SSR 2009 Part-I and connecting to Transformer / Poles all as specified or indicated including testing on , complete all as specified and directed by Engineer-In- Charge. |
| 141 | Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing/connecting as required 25x4 mm galvanised iron strip, complete all as specified and directed by Engineer-In- Charge. |
| 142 | Supply, installing, testing and commissioning factory made LT ( 415 Volts, 50 Hz , 3-phase, 4 wire supply ) CPRI approved, factory assembled Outdoor Feeder Pillar type, weather proof, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated Aluminium bus bars of 300 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, ingress protection class ( IP-54 ) and made of 3.15 mm thick CRCA mild steel sheet and mild steel, Angle iron frame work made out of 40 X 40 X 6 mm ), front and rear opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR wire of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035. embedded in ground with and including bocks of PCC 1:2:4 type B1 of block size 30x30x30 cm comprising of the following:- ( Location :- ) Make of Panel Board:- Adlec/ Schneider / Universal Switch Gear Control. |
| 143 | BUS BAR CHAMBER :- (a) 300 Amps 3 Strips & Neutral Strip 150 Amps, Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.INCOMING SUPPLY :- (i) MCCB 200 Amps 36 KA 4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz,=01 No., Make of MCCB:-L&T/ Schneider / HPL/ Havells.INSTRUMENT FEEDER :- (a) Digital Multi Function Meter with LED display for measurement of Voltage, current, frequency, Power Factor, 96 X 96 mm, 3 Phase- 01 Set. (b) C.T's 200/5 A CL 1.0 Tape Wound- 01 Set. (Set of three)(c) Red, Yellow, Green Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three).(d) Protection MCB 6 A SP C Series- 1 Set. (Set of three). Make of Metering Accessories :-L&T/ AE/ Trinity/ Schneider. |
| 144 | OUTGOING SUPPLY :- (i) MCCB 100 Amps 25 KA 3 Pole with Fixed thermal & magnetic release 415 volts , 50Hz - 04 Nos,Make of MCCB:- L&T/ Schneider / HPL/ Havells.The panel manufacturer should have following Govt. Approved Certificates: 1. Panel should be according to IEC-61439. CPRI Certification Degree of Protection IP-54 (IS/IEC : 61439 (Part-1), 2011 & IS/IEC : 61439 (Part-2) 2011)2. Tempreature Rise (IS/IEC : 61439-1, 2011 & IS/IEC : 61439-2 2011)3. CPRI Short Circuit IEC-61439-1 & 2 withstand strenght should be 70kArms for 1.0 Sec with intial peak of 154kApk4. CPRI Certification IEC-61439-1 & 2 Rated current for short circuit not less than 6300 A with rated insulation voltage 660V5. ISO 9001 CERTIFIED Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail