| 1 | Dismantling of existing brick tiles or terracing tiles on roof, grouted in cement mortar and removal of all debris/ surplus materials and soil etc., to a distance 0.5 km complete all as specified and as directed by Engineer-in-Charge. |
| 2 | Demolition of Mud phuska as in roofs, of any thickness, including PCC padding, plastering and leeping (whether full thickness removed or only a part thereof) with and including removal of any existing treatment upto mother slab and removal of all debries/ surplus material and soil etc., to a distance of 2.5 KM complete all as specified and directed by Engineer-in-Charge. |
| 3 | Demolition of PCC of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-Charge. |
| 4 | M&L for PCC 1:2:4, type B-1 (using 20 mm graded stone aggregates) as in padding on roofs, terraces, sunken and similar works complete all as specified and directed by Engineer-in-Charge. |
| 5 | M&L for rendering 10 mm thick on roof slab/ PCC surface in cement mortar 1:4, using water proofing compound including roughening the surfaces as required complete all as specified and directed by Engineer-in-Charge.(NOTE : WPC will be measured and paid for separately) |
| 6 | Taking down cement or cement lime plaster on brick or stone walls & ceilings etc., including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed by Engineer-in-Charge. |
| 7 | M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces including finishing the surfaces even and smooth complete all as specified and as directed by Engineer-in-Charge. (Note: water proofing compound shall be measured and paid for separately) |
| 8 | Supply only liquid water proofing compound, ISI marked, complete all as specified. |
| 9 | Demolition of brick work built in cement mortar including all quoins, arches, pillars etc., including disposal of rubbish not exceeding 1.5 km complete all as specified and as directed by Engineer-in-Charge. |
| 10 | Material and labour for brick work with fly ash bricks (old size), straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge. |
| 11 | Demolition of RCC (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engineer-in-Charge. |
| 12 | M&L for RCC 1:2:4, type B-1 (using 20 mm graded stone aggregates) as in Fins, fascias, louvres, parapets, and railings exceeding 60 cm in height, newels, balustrade and similar work complete all as specified and as directed by Engineer-in-Charge. |
| 13 | M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge. |
| 14 | M&L for Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses and similar works complete all as specified and as directed by Engineer-in-Charge. |
| 15 | M&L for preparation of newly plastered surfaces of walls with wire brush and washing rubbing down with water including applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @0.90 litre/ 10 sqm over new surfaces including 1 mm thick wall care putty on new plastered wall surface and prepare the surface wall even and smooth all as specified and as directed by Engineer-in-Charge. |
| 16 | S&F PVC (SWR) pipe and vent pipe, 110 mm bore, single socketed in any length with rubber ring joints fixed with solvent fixed to walls with and including MS claimps and PCC in hold fast etc. and making good the disturbed surface including taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., complete all as specified and as directed by Engineer-in-Charge. |
| 17 | S&F PVC (SWR) pipe and vent pipe, 150 mm bore, single socketed in any length with rubber ring joints fixed with solvent fixed to walls with and including MS claimps and PCC in hold fast etc. and making good the disturbed surface, including taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., complete all as specified and as directed by Engineer-in-Charge. |
| 18 | S&F 150 mm PVC (SWR) bend complete all as specified and as directed. |
| 19 | S&F 110 mm PVC (SWR) bend complete all as specified and as directed. |
| 20 | M&L for disconnecting existing tanks exceeding 250 litres not exceeding 500 litres, setting aside (or lowering if required) for repairs, cleaning etc., and hoisting if required reconnecting and re-fixing in position (Cleaning repairing etc. shall be measured separately) complete all as specified and directed by Engineer-in-charge. |
| 21 | M&L for disconnecting existing tanks exceeding 500 litres not exceeding 1000 litres, setting aside (or lowering if required) for repairs, cleaning etc., and hoisting if required reconnecting and re-fixing in position (Cleaning repairing etc. shall be measured separately) complete all as specified and directed by Engineer-in-charge. |
| 22 | S&F Rotational moulded PVC, Triple layered, water storage tanks of capacity 500 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position all as specified in SSR Part I, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including 20 mm size Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe including dismantling of existing tank complete all as specified and as directed by Engineer-in-Charge. |
| 23 | S&F Rotational moulded PVC, Triple layered, water storage tanks of capacity 1000 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position all as specified in SSR Part I, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including 20 mm size Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe including dismantling of existing tank complete all as specified and as directed by Engineer-in-Charge. |
| 24 | M&L to RCC sunshades, chajjas, balconies, coloumns, bands, beams and similar RCC work at any position/ height by dismantling loose/ disintegrated portion including necessary scaffolding and safety arrangements and dubbing out with cement concrete 1:2:4, 15 mm to 50 mm thick, B-0 (using 12.5 mm graded stone aggregate) to make up and finished the required shape with and including finishing with 5 mm thick rendering in cement mortar 1:4 finished even and fair without using extra cement complete all as specified and as directed by Engineer-in-Charge. |
| 25 | M&L for 0.56 mm thick, plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) on crumble joints of wall and roof of any places including demolition of old sheet complete all as specified and as directed by Engineer-in-Charge. |
| 26 | S&F Rolled/ tubular sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe-410 W(Gde E-250) quality B complete all as specified and as directed by Engineer-in-Charge. |
| 27 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet, 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge. |
| 28 | S&F 20 mm bore tubes, medium grade, galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete including taking down old GI pipe with all fittings complete all as specified and directed by Engineer-in-charge. |
| 29 | S&F 15 mm bore tubes, medium grade, galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete including taking down old GI pipe with all fittings complete all as specified and directed by Engineer-in-charge. |
| 30 | S&F Gun-metal globe or gate valves, suitable for 20 mm dia GI pipe with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-charge. |
| 31 | S&F Gun-metal globe or gate valves, suitable for 15 mm dia GI pipe with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-charge. |
| 32 | M&L for providing cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges, coping and similar works complete all as specified and as directed by Engineer-in-Charge. |
| 33 | M&L for preperation of new steel surfaces of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge. |
| 34 | Supply and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner complete all as specified and as directed by Engineer-in-Charge. |
| 35 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge. |
| 36 | Excavating in post holes (or similar holes) each not exceeding 0.5 cum, in any type of soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and as directed by Engineer-in-Charge. |
| 37 | M&L for Cement concrete 1:2:4, Type B-2 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and as directed by Engineer-in charge. |
| 38 | S&F 14 mm thick solid WPC Louvers wall paneling (panel size 192 mmx 2900 mm x 14 mm) fixed to walls with necessary clip screw/ adhesive complete all as specified and as directed by Engineer-in-Charge. |
| 39 | S&F 2 mm thick PVC sheet fillet/ angle/ beading of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and as directed by Engineer-in-Charge. |
| 40 | M&L for Anodised aluminium snap grid frame work for false ceiling and Hangers 6 mm dia. G.I. (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia., 40 mm long complete all as specified and as directed by Engineer-in-Charge. |
| 41 | M&L for 4 mm Non asbestos fibre cement building boards fixed or laid/ inserted to timber/ GI/ Aluminium framework with screws complete all as specified and as directed by Engineer-in-Charge. |
| 42 | M&L for Vitrified Ceramic tiles 10 mm thick dark shade (square/ rectangular) polished, area of each tile exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge. |
| 43 | All as per serial item No. 42.00 here-in-hefore but as in skirting over and including 10 mm rendering in cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge. |
| 44 | S&F 12 mm thick Toughened glass as in hinged doors, partitions, automatic doors and similar work including cutting to shape, drilling holes required complete all as specified and as directed by Engineer-in-Charge. |
| 45 | S&F double action floor spring, hydraulically regulated, made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and as directed by Engineer-in-Charge. |
| 46 | Supply and fixing powder coated aluminium powder coated handles for aluminium doors, 'D' type, 150 mm size complete all as specified and as directed by Engineer-in-Charge. |
| 47 | Supply and fixing factory made uPVC any colour fixed glazed partition/ window/ ventilator made of 67 mm x 64 mm & sash 67 mm x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead of appropriate dimension comprising of uPVC multi-chambered frame and mullion (wherever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 mm x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc., profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc., After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality (Glass shall be paid separately), complete all as per approved drawing & direction of Engineer-in-Charge. |
| 48 | Note: 1. for payment pupose, net area of opening shall be measured.2. For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 49 | S&F 10 mm thick Toughened glass as in hinged doors, partitions, automatic doors and similar work including cutting to shape, drilling holes required complete all as specified and as directed by Engineer-in-Charge. |
| 50 | Supply and fixing factory made uPVC coloured sliding window three track made of extruded profile with wall thickness of 2.30 mm, window profile with hollow section with multi chamber frame (88 mm x 52 mm), sliding sash (42 mm x 67 mm), sliding mesh sash (42 mm x 57 mm), sliding interlock (one vertical length in each shutter) (45.50 mm x 28 mm), Glazing bead (24.5 mm x 16 mm) will be mitered cut and fusion welded at all corners including railing of holes for fixing hardware and drainage etc, making arrangement for fixing of hardware, EPDM gasket 1.2 + 0.2 mm thick, galvanized steel frame (30 mm x 18 mm) 02 Nos, sliding sash (30 mm x 18 mm), sliding mesh sash (26 mm x 10 mm) profile to be inserted in required profile, frame will be fixed to wall with 8 mm x 100 mm long fasteners. Hardware touch lock with zinc alloyed (white powder coated), steel roller system, Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm, 8 mm thick tinted float glass and required accessories complete all as specified and as directed by Engineer-in-Charge. |
| 51 | (NOTE : The unit rate quoted by the contractor shall deemed to include the cost of glass, wire cloth and includes all other connected accessories) |
| 52 | M&L for Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exceeding 1.2 metre length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and as directed by Engineer-in-Charge. |
| 53 | S&F Hangers 6 mm dia G.I. (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia., 40 mm long complete all as specified and as directed by Engineer-in-Charge. |
| 54 | M&L for Providing and fixing 10 mm thick plaster of paris ceiling (Gypsum anhydrous) to round and any sunk and raised moulding surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh (fillets, metal frame work and G.I. wire mesh paid separately) complete all as specified and as directed by Engineer-in-Charge. |
| 55 | Material and labour for preparation of new ceiling surface and applying two coats of distempering with 1st quality acrylic distemper of required shade and colour over one coat of primer all as per manufacturer's specification complete all as specified and as directed by Engineer-in-Charge. |
| 56 | Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good distrubed surfaces of wall, floors, etc complete all as specified and as directed by Engineer-in-charge. |
| 57 | Material and labour for point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm, 1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm, 1100 volts grade for earth continuity conductor to common earth and connected to earth dolly drawn in and including concealed PVC conduit of suitable size bore with all fittings terminated on and including new modular GI metal sunken box of thickness not less than 1.2 mm and suitable size of frame, cover for mounting modular switch, socket and regulator fixed on surface flush with wall, for One light/ bell/ buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator, complete all as specified and as directed by Engineer-in-Charge. |
| 58 | All as per serial item No. 55.00 here-in-before but for socket outlet 3 pin 5 Amps on same board complete all as specified and as directed by Engineer-in-Charge. |
| 59 | All as per serial item No. 55.00 here-in-before but for one socket outlet 3/ 5 pin, 5 amps on independent board complete all as specified and as directed by Engineer-in-Charge. |
| 60 | All as per Serial item No 55.00 here-in-before but for one socket outlet 3/5 pin, 15 amps on independent board size of cable 2.5 sqmm for phase, neutral & 2.5 sqmm as earth wire complete all as specified and as directed by Engineer-in-Charge. |
| 61 | S&F modular switch, one way, 6 Amps, one module, 230 volts, single pole complete all as specified and as directed by Engineer-in-Charge. |
| 62 | S&F modular switch, one way, 16 Amps, one module, 230 volts, single pole complete all as specified and as directed by Engineer-in-Charge. |
| 63 | S&F Modular socket outlet, 2 in 1, 3 pin 6 Amps, single pole, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge. |
| 64 | S&F Socket outlet modular type, multipurpose, 2/3 pin, single pole, two module, 6/16 Amps complete all as specified and as directed by Engineer-in-Charge. |
| 65 | S&F Modular fan step regulator, 120 watts, 2 module complete all as specified and as directed by Engineer-in-Charge. |
| 66 | S&F Ceiling rose 3 pin, 230 volts, PVC polycarbonate insulated body complete all as specified and as directed by Engineer-in-Charge. |
| 67 | S&F modular bell push, 6 Amps, 2 module, single pole complete all as specified and as directed by Engineer-in-Charge. |
| 68 | S&F electric bell, multi music type, AC, 230 Volts, single pole complete all as specified and as directed by Engineer-in-Charge. |
| 69 | Disconnecting and taking down old unserviceable DBs/ junction box etc., of any type and size complete along with all MCBs etc., complete all as specified and as directed. |
| 70 | S&F factory made sheet metal enclosure, single door for MCB distribution board, 2 way, SPN, 240 Volts, having IP43 protection without busbar, complete all as specified and directed by Engineer-in-charge. |
| 71 | S&F factory made sheet metal enclosure, double door for MCB distribution board, 4 way, SPN, 240 Volts, having IP43 protection with 200 Amp rated copper bus bar and din rail neutral link, complete all as specified and directed by Engineer-in-charge. |
| 72 | S&F factory made sheet metal enclosure, double door for MCB distribution board, 8 way, SPN, 240 Volts, having IP43 protection with 200 Amp rated copper bus bar and din rail neutral link, complete all as specified and directed by Engineer-in-charge. |
| 73 | S&F MCCB, 4 pole, 3 phase, 415 volts of capacity 125 Amps, 16 KA with adjustable thermal and magnetic release complete with proper cooper thimble connection complete all as specified and as directed by Engineer-in-charge. |
| 74 | S&F Vertical TPN distribution board, 4 Way, double door with IP-43 protection suitable for MCCB as incomer and MCB as outgoing 415 Volts 3 Phase 50 Hz, complete with appropriate size copper bus bar and neutral link complete all as specified and as directed by Engineer-in-charge. |
| 75 | S&F MCB, single pole and neutral (SP&N), 32 Amp, 240 volts, 10 KA, 'C' series with all incoming/ outgoing connections with proper size lugs, complete all as specified and directed. |
| 76 | S&F MCB, single pole and neutral (SP&N), 40-63 Amp, 240 volts, 10 KA, 'C' series with all incoming/ outgoing connections with proper size lugs, complete all as specified and directed. |
| 77 | S&F MCB, single pole (SP), 6 to 32 Amp, 240 volts, 10 KA, 'C' series with all incomming/ outgoing connections with proper size lugs, complete all as specified and directed. |
| 78 | S&F in repair LED light fitting, 1 x 9W/ 1 x 10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-Charge. |
| 79 | Supply and fixing in repair LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engineer-in-Charge. |
| 80 | Supply and fixing in repair LED light fitting, mirror light with high out put diffuser, 2 feet, 10 watt, 220 V, AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-Charge. |
| 81 | Earthing complete with and including galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected with and including galvanised iron or steel earth wire, 4 mm dia (No. 8 SWG) by means bolts, nuts, check nuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25, reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SSR Part-I (2009) complete all as specified and directed by Engineer-in-Charge. |
| 82 | Note : The unit rate includes for protecton pipe 15 mm and GI wire 4 mm dia from top of earth plate upto 7.50 metre. |
| 83 | Supply and fixing exhaust fan, made of sturdy Engineering plastic body complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300 mm complete all as specified and as directed by Engineer-in-Charge. |
| 84 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, BEE 5 star rated with brushless direct current motor (BLDC) including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by engineer-in-charge. |
| 85 | Supply and fixing heavy duty air circulator wall mounted fan, 450 mm sweep, three blades, alloy steel operating voltage at 220-240V with all mounting accessories complete all as specified and as directed by Engineer-in-Charge. |
| 86 | Supply and fixing of electric water heater, storage type, steel body with copper inner tank and heating element upto 2 KW capacity, 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. and including taking down unserviceable water heater and deposit to E/M Store complete all as specified and as directed by Engineer-in-Charge. |
| 87 | Disconnecting and taking down old unserviceable sub main wiring (copper/ aluminium) complete with batten/ conduit of any type and size removing materials and making good disturbed surfaces of walls, floors etc., complete all as specified and directed by Engineer-in-charge. |
| 88 | M&L for Sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLSH) cable of size 4.0 sqmm, LT, 1100 Volts grade, drawn through and including adequate size PVC non metallic conduit of 20 mm/ appropriate dia with accessories and fittings and one run of 4.0 sqmm single core multi stranded copper conductor (FRLSH) cable as earth continuity conductor with accessories and fittings and connecting to existing main switch board/ DB and testing on completion complete all as specified and as directed by Engineer-in-Charge. |
| 89 | M&L for Sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLSH) cable of size 6.0 sqmm, LT, 1100 Volts grade, drawn through and including adequate size PVC non metallic conduit of 20 mm/ appropriate dia with accessories and fittings and one run of 6.0 sqmm single core multi stranded copper conductor (FRLSH) cable as earth continuity conductor with accessories and fittings and connecting to existing main switch board/ DB and testing on completion complete all as specified and as directed by Engineer-in-Charge. |
| 90 | M&L of Sub main wiring with four runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLSH) cable of size 16.0 sqmm, LT, 1100 Volts grade, drawn through and including adequate size PVC non metallic conduit of 32 mm/ appropriate dia with accessories and fittings and one run of 16.0 sqmm single core multi stranded copper conductor (FRLSH) cable as earth continuity conductor with accessories and fittings and connecting to existing main switch board/ DB and testing on completion complete all as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
| 91 | M&L of Sub main wiring with four runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLSH) cable of size 16.0 sqmm, LT, 1100 Volts grade, drawn through and including adequate size PVC non metallic conduit of 32 mm/ appropriate dia with accessories and fittings and one run of 16.0 sqmm single core multi stranded copper conductor (FRLSH) cable as earth continuity conductor with accessories and fittings and connecting to existing main switch board/ DB and testing on completion complete all as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |