| 1 | 2.8 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual mean foundation or drains (not exceeding 1.5m in width or 10 Sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. All kinds of soil |
| 2 | 4.1.3 Providing and laying in position cement concrete of specified grade excluding cost of centering and shuttering all works upto plinth level. 1:2:4 (1 cement : 2 coarse sand (Zone - III) derived from natural source : 4 graded stone aggregate 20mm nominal size derived from natural source) |
| 3 | 5.2.2 Reinforced cement concrete in walls (any thickness) including attached plasters, buttresses, plinth and string courses, filters, columns, pillars, piers, abutments, posts and struts etc. above plinth upto floor level excluding the cost of centering, shuttering, finishing and reinforcement.1:1.5:3 (1 cement : 1.5 coarse sand (Zone-III) derive : 3 graded stone aggregate 20mm nominal size derived from natural sources) |
| 4 | 6.1.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in : Cement Mortar 1:4 (1 cement : 4 coarse sand) |
| 5 | 6.13.2 Half brick masonary with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure abopve plinth level upto floor V level. Cement Mortar 1:3 (1 cement : 3 coarse sand) |
| 6 | 16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 7 | 4.1 Providing and laying damp proof course 40mm thick with cement concrete 1:2:4 (1cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 8 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns etc. for mass concrete |
| 9 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 10 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for : Columns, pillars, piers, abutments, posts and struts |
| 11 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for : Weather shade, Chajjas, corbets etc., including edges |
| 12 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick |
| 13 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 14 | 13.1 12mm cement plaster of mix : 1:4 (1 cement : 4 fine sand) |
| 15 | 13.2 15mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement : 4 fine sand) |
| 16 | 11.5 62mm thick cement concrete flooring with concrete hardener topping, under layer 50mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 Kg. of cement or as per manufacture's sprcifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 17 | 9.1 Providing wood work in frames of doors, windows, clerestory windowsand other frames, wrought framed and fixed in position with hold fastlugs or with dash fasteners of required dia & length (hold fast lugs ordash fastener shall be paid for separately).9.1.1 Second class teak wood |
| 18 | Providing construct the Drain around the bilding all composite as directed @4124.5/m |
| 19 | 9.27 Providing and fixing wire gauge shutters using galvanized M.S. wiregauge of average width of aperture 1.4 mm in both directions with wireof dia 0.63 mm, for doors, windows and clerestory windows with hingesand necessary screws9.27.2 30 mm thick shutters9.27.2.1 with ISI marked M.S. pressed butt hinges brightfinished of required size9.27.2.1.1 Second class teak wood |
| 20 | 9.5 Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows, fixing with butt hinges of requiredsize with necessary screws, excluding panelling which will be paid forseparately, all complete as per direction of Engineer-in-charge. (Note:-Butt hinges and necessary screws shall be paid separately)9.5.1 Second class teak wood9.5.1.2 30 mm thick shutters |
| 21 | 13.80 Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete. |
| 22 | 9.9 Providing and fixing glazed shutters for doors, windows and clerestorywindows using 4 mm thick float glass panes, (weight not less than10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges brightfinished of required size with necessary screws.9.9.1 Second class teak wood9.9.1.1 35 mm thick |
| 23 | 10.6 Supplying and fixing rolling shutters of approved make, made of requiredsize M.S. laths, interlocked together through their entire length andjointed together at the end by end locks, mounted on specially designedpipe shaft with brackets, side guides and arrangements for inside andoutside locking with push and pull operation complete, including thecost of providing and fixing necessary 27.5 cm long wire springsmanufactured from high tensile steel wire of adequate strengthconforming to IS: 4454 - part 1 and M.S. top cover of required thicknessfor rolling shutters.10.6.1 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 24 | 9.48.1 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding |
| 25 | 12.45.1 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive)as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200 centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x 10 x 0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45 x 15 x 0.9 mm running at the spacing of 1200mm centre to centre,.....suitable for board, all as per manufacture's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer-in-Charge but excluding the cost of painting with :12.5mm thick tapered edge gypsum plain board conforming to IS:2095 (Part-I) : 2011 (Board with BIS certification marks) |
| 26 | 10.16 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes. |
| 27 | 12.1.3 Providing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead,including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63mm thick with zinc coating not less than 275gm/m2 |
| 28 | 12.4 Providing ridges or hips of width 60cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. 0.63mm thick with zinc coating not less than 275gm/ m2 |
| 29 | 12.45 Providing and fixing false ceiling at all height including providing andfixing of frame work made of special sections, power pressed fromM.S. sheets and galvanized with zinc coating of 120 gms/sqm (bothside inclusive) as per IS : 277 and consisting of angle cleats of size25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at1200 mm centre to entre............12.45.1 12.5 mm thick tapered edge gypsum plain boardconforming to IS: 2095- (Part I) :2011 (Board with BIScertification marks) |
| 30 | 9.7.8 Fly proof stainless steel grade 304 wire gauge with 0.5 mmdia. wire and 1.4mm wide aperture with matching woodbeading |
| 31 | 8676 Precoated galvanised steel barge board (upto 300mm ) |
| 32 | 13.42 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/ litre, of approved manufacturer, of required shade and colour complete, as per manufacture's specification.Two or more coats on new work |
| 33 | 13.44 Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @3.84 Kg/ 10sqm) |
| 34 | 13.48 Finsihing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Painting steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/ 10sqm over an under coat of primer applied @0.80 ltr/ 10sqm of approved brand and manufacture. |
| 35 | 13.50.1Applying priming coat : With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 36 | 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 37 | 1.1.1 Wiring for light/Fan/call bell point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit, with piano type switch phenolic laminated sheet, suitable size M/s box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group A |
| 38 | 1.1.2 Wiring for light/Fan/call bell point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit, with piano type switch phenolic laminated sheet, suitable size M/s box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group B |
| 39 | 1.1.3 Wiring for light/Fan/call bell point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit, with piano type switch phenolic laminated sheet, suitable size M/s box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 40 | 1.3.2 Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group B |
| 41 | Wiring for light point fan point/call bell point with 1.5 sq.mm FRLS P.V.C insulated cooper conductor single core. Cable in surface/ressed steel conduit with piano type switch ------- single core cable etc. |
| 42 | 1.7.5 Wiring for circuit wiring alongwith earth wire with the following size of LRLS PVC insulated copper conductor single core cable in surface/ Recessed steel conduit as require2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 43 | 1.7.4 Wiring for circuit wiring alongwith earth wire with the following size of LRLS PVC insulated copper conductor single core cable in surface/ Recessed steel conduit as required 2x6 sq.mm. + 1x6 sq. mm. earth wire |
| 44 | 2.1.2 Providing and fixing following capacity TP & N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections etc. as required. 63A TP & N |
| 45 | Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, diA bar, interconnections, powder painted including earthing etc. |
| 46 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc. as required. 200 mm width x 50mm depth x1.6mm thickness. |
| 47 | Earthing with copper earth plate 600mm x600mm x 3mm thick including accessories, and providing masonry enclosuer with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. |
| 48 | Supplying, installation, testing and commissioning of 1200mm sweep, BEE 5 star rated ceiling fan with Bruss Less Direct corrent (BLDC) Motor, class of insulation:B, 3 Nos,, blades, 30 cm longdown rod, 2Nos, 2Nos canopies, shackle kit, safety rope-----as required. |
| 49 | Wiring for light/power plug with 4x4 sqmm FRLS P.V.C insulated insulated cooper conductor single core cable in surface recessed steel conduit along with 2 Nos. 4sqmm. FRLS P.V.C insulated copper conductor single core cable for loop earthing as required. |
| 50 | Wiring for circuit sub main wiring alongwith earth wire with the following size of FRLS P.V.C. insulated copper conductor single core cable in surface/recessed steel conduit as required 2x 6 sqmm+ 1x 6sq mm earth wire |
| 51 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. |
| 52 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. |
| 53 | Providing and fixing following capacity TP & N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections etc. as required. 63A TP & N |
| 54 | Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, diA bar, interconnections, powder painted including earthing etc. |
| 55 | ASEB Connection (R.s.8000.00/KV) |
| 56 | Earthing with copper earth plate 600mm x600mm x 3mm thick including accessories, and providing masonry enclosuer with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. |