| 1 | 2.6.1 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 2.6.1 All kinds of soil |
| 2 | 16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 3 | 4.1 Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel : 4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived fromnatural sources : 4 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 4 | 5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing andreinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources) |
| 5 | 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in:6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 6 | 5.22 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 7 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns etc. for mass concrete |
| 8 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for : Coulumns, Pillars, Piers, Abutments, Posts and Struts |
| 9 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 10 | 9.7.8 Fly proof stainless steel grade 304 wire gauge with 0.5 mmdia. wire and 1.4mm wide aperture with matching woodbeading |
| 11 | 9.27 Providing and fixing wire gauge shutters using galvanized M.S. wiregauge of average width of aperture 1.4 mm in both directions with wireof dia 0.63 mm, for doors, windows and clerestory windows with hingesand necessary screws :9.27.1.2 With ISI marked stainless steel butt hinges ofrequired size9.27.1.2.1 Second class teak wood |
| 12 | 4.10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 13 | 2.25a Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20cm in trenches, plinth, sides of foundation etc. complete |
| 14 | 6.13.2 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) |
| 15 | 12.45 Providing and fixing false ceiling at all height including providing andfixing of frame work made of special sections, power pressed fromM.S. sheets and galvanized with zinc coating of 120 gms/sqm (bothside inclusive) as per IS : 277 and consisting of angle cleats of size25 mm wide ................12.45.1 12.5 mm thick tapered edge gypsum plain boardconforming to IS: 2095- (Part I) :2011 (Board with BIScertification marks) |
| 16 | 13.80 Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete. |
| 17 | Providing drain all round the building as directed @ 1859.10/3 |
| 18 | 10.16.1 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 19 | 12.1.2 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever |
| 20 | 12.4.1 Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.v0.63 mm thick with zinc coating not less than 275 gm/m² |
| 21 | 13.85 Applying priming coats with primer of approved brand andmanufacture, having low VOC (Volatile Organic Compound ) content.13.85.1 With ready mixed pink or grey primer on wood work(hard and soft wood) having VOC content less than50 grams/ litre |
| 22 | 13.44 Finishing walls with water proofing cement paint of required shade :13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 23 | 13.8.2 Cement plaster skirting up to 30cm ht. with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement finish. 18mm thick |
| 24 | 13.50.1Applying priming coat : With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 25 | 13.48.1 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications 13.48.2 :- Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 26 | 8676 Precoated galvanised steel barge board (upto 300mm ) |
| 27 | 1.1.1 Wiring for light point fan point/call bell point with 1.5 sq.mm FRLS P.V.C insulated cooper conductor single core. Cable in surface/ressed steel conduit with piano type switch ------- single core cable etc.Group A |
| 28 | Wiring for light point fan point/call bell point with 1.5 sq.mm FRLS P.V.C insulated cooper conductor single core. Cable in surface/ressed steel conduit with piano type switch ------- single core cable etc. Gb B |
| 29 | 1.3 Wiring for light point fan point/call bell point with 1.5 sq.mm FRLS P.V.C insulated cooper conductor single core. Cable in surface/ressed steel conduit with piano type switch ------- single core cable etc. Group B |
| 30 | 1.6 Wiring for light/power plug with 4x4 sqmm FRLS P.V.C insulated insulated cooper conductor single core cable in surface recessed steel conduit along with 2 Nos. 4sqmm. FRLS P.V.C insulated copper conductor single core cable for loop earthing as required. |
| 31 | 1.7.1 Wiring for circuit sub main wiring alongwith earth wire with the following size of FRLS P.V.C. insulated copper conductor single core cable in surface/recessed steel conduit as required 2x 1.5sqmm+ 1x1.5sq mm earth wire |
| 32 | 1.7.2 Wiring for circuit sub main wiring alongwith earth wire with the following size of FRLS P.V.C. insulated copper conductor single core cable in surface/recessed steel conduit as required 2x 2.5sqmm+ 1x 2.5 sq mm earth wire |
| 33 | 1.7.4Wiring for circuit sub main wiring alongwith earth wire with the following size of FRLS P.V.C. insulated copper conductor single core cable in surface/recessed steel conduit as required 2x 6 sqmm+ 1x 6sq mm earth wire |
| 34 | Wiring for circuit sub main wiring alongwith earth wire with the following size of FRLS P.V.C. insulated copper conductor single core cable in surface/recessed steel conduit as required 2x 10 sqmm+ 1x 6sq mm earth wire |
| 35 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length up to 30cm with 1.5 sq. mm FRLS PVC insulated copper conductor, single core cable etc. as required. |
| 36 | Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, diA bar, interconnections, powder painted including earthing etc. |
| 37 | Supplying and fixing following rating, double pole, 240V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A |
| 38 | Earthing with copper earth plate 600mm x600mm x 3mm thick including accessories, and providing masonry enclosuer with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. |
| 39 | Supplying, installation, testing and commissioning of 1200mm sweep, BEE 5 star rated ceiling fan with Bruss Less Direct corrent (BLDC) Motor, class of insulation:B, 3 Nos,, blades, 30 cm longdown rod, 2Nos, 2Nos canopies, shackle kit, safety rope-----as required. |
| 40 | ASEB Conection & Load Security (Rs.8000.00/ KVA) |
| 41 | L Hook Please Enable Macros to View BoQ information |