| Sl. No. | Item Description |
| 1 | Trenching in ordinary soil up to a depth of 60cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly levelling with in a lead of 50m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). |
| 2 | Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment). |
| 3 | Supplying and stacking sludge at site including royalty and carriage up to 1 km (sludge measured in stacks will be reduced by 8% for payment). |
| 4 | Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. |
| 5 | Fine dressing the ground. |
| 6 | Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Officer-in-charge (Cost of sludge, dump manure and / or good earth to be paid separately). |
| 7 | Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.. |
| 8 | Grassing with ‘Doob’ grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for mowing including supplying good earth if needed (the good earth shall be paid for separately). In rows 5 cm apart in either direction. In rows 7.5 cm apart in either direction. |
| 9 | Preparation of beds for hedging and shrubbery by excavating cu.m 60cm deep and trenching the excavated base to a further depth of 30cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water,filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50m lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately). |
| 10 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) Holes 60 cm dia, and 60 cm deep. |
| 11 | Providing and fixing M.S. flat iron tree guard 60 cm dia and 2 m high, above ground consisting 4 nos 25 x 6 mm, 2.25 m long and 8 nos 25 x 3 mm 2 m long verticals M.S. flats, riveted to 3 nos 25 x 6 mm M.S. flat iron rings in two halves, fixing together at site with required six numbers of 8 mm dia. and 30 mm long bolts, including painting two coats with synthetic enamel paint of approved brand and manufacture over a coat of primer. One name plate of 1 mm thick M.S. sheet of size 250x100 mm shall be welded to the tree guard near the middle height and lettered CPWD / PWD/ any other approved name. The tree guard shall be suitably fixed to the ground by embedding four legs of tree guard in pits of suitable dia and to a depth of 25 cm, refilling the pits with soil and ramming, complete in all respect as per satisfaction and direction of Officer-in-charge. |
| 12 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 13 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil |
| 14 | Treatment of soil under floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration |
| 15 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 16 | Supplying and filling in plinth with Local sand under floors, including watering, ramming, consolidating and dressing complete. |
| 17 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 18 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size). |
| 19 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 20 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). Work Up to plinth Level |
| 21 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).. Work above to plinth level upto floor V level |
| 22 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. |
| 23 | Centring and shuttering for foundations, footings, bases of columns, etc. for mass concrete |
| 24 | Centring and shuttering for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 25 | Centring and shuttering for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 26 | Centring and shuttering for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 27 | Centring and Shuttering for Suspended floors, roofs, landings, balconies and access platform |
| 28 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1 :6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1 :6 (1 cement: 6 coarse sand) |
| 29 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 30 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 31 | Half brick masonry with F.P.S. bricks of class designation 75 in superstructure 1:4 (1 cement : 4 coarse sand) |
| 32 | Extra for providing and placing in position 2 Nos. 6mm dia. M.S. sq.m bars at every third course of half brick masonry (with F.P.S. bricks). |
| 33 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth |
| 34 | Brick edging 7cm wide 11.4cm. deep to plinth protection with bricks of class designation 75 including grouting with cement mortar 1:4 (1 cement : 4 fine sand) |
| 35 | 12 mm cement plaster of mix 1:6 (1 cement : 6 fine sand) |
| 36 | 15 mm cement plaster on rough side of single or half brick wall of mix 1: 6 (1 cement: 6 fine sand) |
| 37 | 6 mm cement plaster of mix 1:3 (1 cement: 3 fine sand) |
| 38 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement 12 mm cement plaster |
| 39 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete. |
| 40 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to sq.m IS : 15622 (thickness to be specified by the manufacture ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 41 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 42 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick |
| 43 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 44 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 45 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 46 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab upto 0.50 sqm |
| 47 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. . Marble work |
| 48 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work |
| 49 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. White Agaria Marble Stone |
| 50 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 51 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strikeplate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineerin-charge: Fixing with adjustable lugs with split end tail to each jamb. |
| 52 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 53 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 54 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size Second class teak wood |
| 55 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 56 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 57 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides |
| 58 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 59 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows alll complete. |
| 60 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : (125mm) |
| 61 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete (200X10mm) |
| 62 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete . (150X10mm) |
| 63 | Providing and fixing aluminium sliding door bolts, ISI marked anodised anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm |
| 64 | Providing and fixing aluminium sliding door bolts, ISI marked anodised anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : (250x16 mm) |
| 65 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality). |
| 66 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. |
| 67 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 68 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete :300x16 mm |
| 69 | Providing and fixing ISI marked oxidised M.S. pressed butt hinges with necessary screws etc. complete. 125x65x2.12 mm |
| 70 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (200X10mm) |
| 71 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete. (150X10mm) |
| 72 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete(125mm) |
| 73 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (100 mm) |
| 74 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete. 75mm |
| 75 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (100x10 mm) |
| 76 | Providing and fixing oxidised M.S. casement stays. 200 mm weighing not less than 120 gms |
| 77 | Providing and fixing nickel plated M.S. pipe curtain rods 20 mm dia (heavy type) |
| 78 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 12 mm mild steel U beading |
| 79 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding |
| 80 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes |
| 81 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, kilogram gates |
| 82 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 83 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 84 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including priming coat with cement primer |
| 85 | Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm). |
| 86 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 87 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade |
| 88 | Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50 m x2.00 m made of 40x40x6 mm angle iron or 50x50x3 mm hollow MS tube posts/horizontal members/bracings covered with 1.63 mm thick MS sheet. The sheet shall be fixed with 30x5 mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5 m. MS channel ISLC 75 @ 5.70 kg/m, 50 cm long shall be provided at the bottom having oval shaped holes of size 50x25 mm at both ends with 50 cm long MS barricading to avoid from overturning by providing 250 mm long expansion fasteners at both ends. The work shall be executed as per drawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously including shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. |
| 89 | Stone tile work for wall lining upto 10 m height with special adhesive over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shade. 8 mm thick (mirror polished and machine cut edge) Granite stone of any colour and shade |
| 90 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.. 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. |
| 91 | Grading roof for water proofing treatment with Cement mortar 1:4 (1cement : 4 coarse sand). |
| 92 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams pe sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete . Ridges plain (500 - 600mm) |
| 93 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams pe sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete .Gutter (600 mm over all girth) |
| 94 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 110 mm diameter |
| 95 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories Bend 87.5° 110 mm bend |
| 96 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories 110 mm Shoe (Plain) |
| 97 | Supply and fixing of Bison Board 12 mm thick Over Truss Frame Including all Labours, Material T&P Etc. |
| 98 | Supply and fixing Shingles with Required Overlapping Over Bison Board 12 mm thick with Tarfelt Sheet Including all Labours, Material T&P Etc. |
| 99 | Providing and fixing specified wood frame work consisting of battens 50x25 mm fixed with rawl plug and drilling necessary holes for rawl plug etc. including priming coat complete. Devdore Wood |
| 100 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.. 15 mm dia. nominal bore |
| 101 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.. 20 mm dia. nominal bore |
| 102 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 20 mm dia. nominal bore |
| 103 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 25 mm dia. nominal bore |
| 104 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 32 mm dia. nominal bore |
| 105 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore |
| 106 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore |
| 107 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore |
| 108 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. Flexible pipe 32mm dia |
| 109 | Providing and fixing uplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore |
| 110 | Providing and fixing ball valve (brass) of approved quality complete High or low pressure with plastic floats 20 mm nominal bore |
| 111 | Providing and fixing brass stop cock of approved quality 20 mm nominal bore |
| 112 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) . 25 mm dia. nominal bore |
| 113 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) . 32 mm dia. nominal bore |
| 114 | Providing and fixing white vitreous china pedestal type water = closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 115 | Providing and fixing toilet paper holder :C.P. brass |
| 116 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 117 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass each pillar tap |
| 118 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 119 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm |
| 120 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter |
| 121 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cisternn |
| 122 | Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mmwith 1/2\\" BSP thread and shapes, weighing not less than 60 gms. |
| 123 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shades with 6 mm thick hard board backing: of Rectangular shape 453x357 mm |
| 124 | Providing and fixing 600x120x5mm glass shelf with edges round of supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 125 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 126 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast For 100 mm dia. Pipe |
| 127 | Providing and fixing PTMT towel ring trapezoidal shape 215mm long, 200mm wide with a minimum distances of 37mm from wall face with concealed fittings arrangement of approved quality and colours weighing not less than 80 gms than 106 gms. |
| 128 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 129 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102 mm, height of 75mm with concealed fitting arrangements weighing not less |
| 130 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour 20mm nominal bore. Weighing not less than 40gms. |
| 131 | Providing and fixing PTMT grating of approved quality and colour. Circular type.. 100 mm nominal dia. |
| 132 | Providing and fixing PTMT grating of approved quality and colour. Circular type.. 125 mm nominal dia with 25 mm waste hole |
| 133 | Providing and fixing PVC Coupler (75 mm dia) |
| 134 | Providing and fixing PVC Coupler (110 mm dia) |
| 135 | Providing and fixing PVC Shoe (Plain) (75 mm dia) |
| 136 | Providing and fixing PVC Shoe (Plain) (110 mm dia) |
| 137 | Providing and fixing PVC plain bend of required degree. ( 75 mm dia) |
| 138 | Providing and fixing PVC plain bend of required degree. ( 110 mm dia) |
| 139 | Providing and fixing PVC Single tee with door required degree access door 75x75x75x110mm |
| 140 | Providing and fixing PVC Single tee with door required degree access door 110x110x100x110mm |
| 141 | Providing and fixing on wall face unplasticised Rigid PVC pipes (75 mm dia) |
| 142 | Providing and fixing on wall face unplasticised Rigid PVC pipes (110mm dia) |
| 143 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (110mm dia) For External Work |
| 144 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 19.19.1 L D- 2.5 Square shape 450 mm internal dimensions |
| 145 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey With F.P.S. bricks |
| 146 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement With 20x20 mm square bar |
| 147 | Supplying and Laying at site 90 mm to 45 mm size stone aggregate For Filteratioon Tank including s\upply of all materials T & P etc. Complet. |
| 148 | Providing and fixing trap (75 mm dia) |
| 149 | Providing and fixing trap (110 mm dia) |
| 150 | Supplying & Installation of 3 seater Multiseater Bench with Power Coated Leg and Arm complete in all respect as per site Engineer incharge |
| 151 | Excavation in soil in Hilly Area by mechanical meansExcavation in soil in Hilly Area by mechanical means Without useinng Dozer including cutting and trimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per Technical Specification Clause 1603.1 |
| 152 | Excavation in Hilly Areas in Ordinary Rock by mechanical means not requiring blastingExcavation in hilly area in ordinary rock not requiring blasting by mechanical means including cutting and trimming of slopes and disposal of cut material with a lift upto 1.5 m and lead upto 20 m as per Clause 1603.2 |
| 153 | Excavation in Hilly Areas in Hard Rock requiring blastingExcavation in hilly areas in hard rock requiring blasting, by mechanical means, lift upto 1.5 m and disposal of excavated rock upto a lead of 20 m as per Clause 1603.2. |
| 154 | Construction of Embankment with Material Obtained from Roadway Cutting Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 |
| 155 | Excavation for StructuresEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. |
| 156 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 15 |
| 157 | Brick masonry work in cement mortar in foundation complete bnexcluding pointing and plastering bas per drawing and technical specifications Clauses 600, 1202 & 1203 Brick masonry in 1:4 cement mortar |
| 158 | Brick masonry work in cement mortar in substructure complete excepting pointing and nplastering, as per drawing and technical specification Clauses 602, 603, 604, 1202 & 1204 |
| 159 | Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204 |
| 160 | Random Rubble Stone Masonry laid Dry, in breast walls, retaining walls, etc. nincluding supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction |
| 161 | Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction |
| 162 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 R.C.C. grade M 25 |
| 163 | Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 (The reinforcement steel shall be procured from original (primary) steel producers as per clause no. 2011.3.1 of MORD specifications (First revision'2014) and IS 1786:2008 clause no. 1.6) |
| 164 | Hand Packed stone filling in back of wallls including cost of all materials, royality, T&P etc. complete as per direction of Engineer-in- charge. (As per PWD Uttarakhand specifications) |
| 165 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 |
| 166 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (For height upto 5 m) P.C.C. grade M 20 |
| 167 | Cast in Situ Cement Concrete M20 kerb(Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 bmm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408) Using Concrete Mixer |
| 168 | Cast in Situ Cement Concrete M 20 Kerb with Channel(Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408) Using Concrete Mixer |
| 169 | Granular Sub-base with Well Graded Material (Table 400.1) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. |
| 170 | WBM Grading 3Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. |
| 171 | Cement Concrete PavementConstruction of un-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 Cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days, using curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause 1501 |
| 172 | Providing and Laying of Interlocking Concrete Block (M-35) Pavements having thickness 60 mm as per drawings and Technical Specification Clause 1504. |
| 173 | Footpaths and Separators(Construction of footpath/separator by providing a 150 mm compacted granular sub base as per clause 401 and 25 mm thick cement concrete grade M15, over laid with precast concrete tiles in cement mortar 1:3 including provision of all drainage arrangements but excluding kerb channel..) |
| 174 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1 :3 (1 cement: 3 coarse sand) including pointing in white cement mortar 1 :2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Red sand stone - exposed face fine dressed with rough (30 mm thick) |
| 175 | French spirit polishing : Two or more coats on new works including a coat of wood filler |
| 176 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group - C MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 177 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 178 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire) MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 179 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire) MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 180 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (2 X 4 sq. mm + 1 X 4 sq. mm earth wire).MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 181 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (2 X 6 sq. mm + 1 X 6 sq. mm earth wire) MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 182 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (2 x 10 sq.mm + 1 x 6 sq.mm. earth wire).MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 183 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (4 x 4 sq.mm + 2 x 4 sq.mm. earth wire).MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 184 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (4 x 6 sq.mm + 2 x 6 sq.mm. earth wire).MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 185 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (4 x 10 sq.mm + 2 x 6 sq.mm. earth wire).MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 186 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (4 x 16 sq.mm + 2 x 6 sq.mm. earth wire).MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 187 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required.MAKE:ANCHOR,HAVELLS, ABB |
| 188 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.MAKE:ANCHOR,HAVELLS, ABB |
| 189 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).MAKE:ANCHOR,HAVELLS, ABB |
| 190 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required..MAKE:ANCHOR,HAVELLS, ABB |
| 191 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 192 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 193 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch.MAKE:ANCHOR,HAVELLS, ABB |
| 194 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet.MAKE:ANCHOR,HAVELLS, ABB |
| 195 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 196 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 197 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 198 | Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 199 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 200 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 201 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 510 mm sweep |
| 202 | Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. |
| 203 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 204 | Supply of LED 4ft 36W LED suspended light with main cable & End cap, suitable for 24Hr Continuous Operation, 4000 system lumens, 110lm/W, PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 25000Hrs @L70, complete in all respect.MAKE:-HAVELLS, ,PHILIPS,OSRAM |
| 205 | Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PC diffuser. The total power consumption should not exceed 21W (including driver).MAKE:-HAVELLS, ,PHILIPS,OSRAM |
| 206 | Supply of Surface mounting round 6 Watt 10 Watt , LED Down Lighter, suitable for 24Hr Continuous Operation, 660-1100 system lumens, 110lm/W, PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, complete in all respect.MAKE:-HAVELLS, ,PHILIPS,OSRAM |
| 207 | Supply of Surface mounting round 12 Watt 15 Watt , suitable for 24Hr Continuous Operation, 100lm/W, PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, complete in all respect. MAKE:-HAVELLS, ,PHILIPS,OSRAM |
| 208 | Supply of Surface mounting square 18 to 20 Watt , suitable for 24Hr Continuous Operation, 100lm/W, PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, complete in all respect. MAKE:-HAVELLS, ,PHILIPS,OSRAM |
| 209 | Supply of LED mirror light luminaire with 10W watt complete with electronic ballast, lamp including connection etc. complete as required, MAKE:-HAVELLS, ,PHILIPS,OSRAM |
| 210 | Supply of LED Flood light 50 Watt , suitable for 24Hr Continuous Operation, 110lm/W, PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, CCT 3000K, complete in all respect, MAKE:-HAVELLS, ,PHILIPS,OSRAM |
| 211 | Supply of 9W to 15 W 3 Star LED Wall Light Blub complete in all respect.MAKE:-HAVELLS, ,PHILIPS,OSRAM |
| 212 | Supply of Recessed mounting round 12 Watt 15 Watt , suitable for 24Hr Continuous Operation, 100lm/W, PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, complete in all respect. MAKE:-HAVELLS, ,PHILIPS,OSRAM |
| 213 | Supply of Recessed mounting round 6 Watt 10 Watt , LED Down Lighter, suitable for 24Hr Continuous Operation, 660-1100 system lumens, 110lm/W, PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, complete in all respect.MAKE:-HAVELLS, ,PHILIPS,OSRAM |
| 214 | Supply of Decorative LED Wall Light complete in all respect. MAKE:-HAVELLS, ,PHILIPS,OSRAM |
| 215 | Supply & Fixing of Recessed mounting 2x2 feet 24 to 30W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W, PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, complete in all respect.MAKE:-HAVELLS, ,PHILIPS,OSRAM |
| 216 | Supply of LED 4ft 50W LED suspended light with main cable & End cap, suitable for 24Hr Continuous Operation, 5000 system lumens, 110lm/W, PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 25000Hrs @L70, complete in all respect.MAKE:-HAVELLS, ,PHILIPS,OSRAM |
| 217 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan. MAKE:-HAVELLS, USHA,CROMPTON,BAJAJ. |
| 218 | Supplying of 400 mm Wall Fan complete in all respect. MAKE:-HAVELLS, USHA,CROMPTON,BAJAJ. |
| 219 | Supply of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.300mm EXHAUST FAN MAKE:-HAVELLS, USHA,CROMPTON,BAJAJ. |
| 220 | Supply of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.600mm EXHAUST FAN MAKE:-HAVELLS, USHA,CROMPTON,BAJAJ. |
| 221 | Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double Door. MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 222 | Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)16 way, Double Door. MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 223 | Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double Door. MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 224 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 Way Double door. MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 225 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole. MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 226 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole. MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 227 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral. MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 228 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole . MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 229 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 230 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 231 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 40 A,25KA,FP MCCB. MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 232 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way Double door. MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 233 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way Double door. MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 234 | Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.) 4 way (4 + 12), Double door. MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 235 | Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required Make L&T BB40400C or Eq.63 amps 4P MCB. MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 236 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required.25 amps. MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 237 | Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only..; Note:- All panel will be TTA Panel. INCOMER:-1 No 200 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking Capacity.METERING :-1 No. Multi Function Meter,1 Set of phase indicating lamps with Single Pole MCB,1 Set of ON / OFF indicating lamps with Single Pole MCB.BUS BARS:-300 Amps. TP&N aluminium bus bars OUT GOINGS:-15 Nos. 32 Amps. FP MCB,2 Nos. Space & Spare.MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 238 | Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A only..; Note:- All panel will be TTA Panel. INCOMER:-1 No 100 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking Capacity.METERING :-1 No. Multi Function Meter,1 Set of phase indicating lamps with Single Pole MCB,1 Set of ON / OFF indicating lamps with Single Pole MCB.BUS BARS:-150 Amps. TP&N aluminium bus bars .OUT GOINGS:-7 Nos. 32 Amps. FP MCcB,2 Nos. Space & Spare.MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 239 | Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A only.Note:- All panel will be TTA Panel. INCOMER:-1 No 160 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking Capacity,1 No 40 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking Capacity.METERING :-1 No. Multi Function Meter,1 Set of phase indicating lamps with Single Pole MCB,1 Set of ON / OFF indicating lamps with Single Pole MCB.BUS BARS:-250 Amps. TP&N aluminium bus bars.OUT GOINGS:-15 Nos. 32 Amps. FP MCB (10 KA),2 Nos. Space & Spare.MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 240 | Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A only.Note:- All panel will be TTA Panel. INCOMER:-1 No 100 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking Capacity,1 No 32 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking Capacity METERING :-1 No. Multi Function Meter,2 Set of phase indicating lamps with Single Pole MCB,2 Set of ON / OFF indicating lamps with Single Pole MCB.BUS BARS:-150 Amps. TP&N aluminium bus bars.OUT GOINGS:-2 Nos. 63 Amps. FP MCB (10 KA),4 Nos. 32 Amps. FP MCB (10 KA),2 Nos. Space & Spare.MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 241 | Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A only.Note:- All panel will be TTA Panel. INCOMER:-1 No 125 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking Capacity,1 No 40 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking Capacity.METERING :-2 No. Multi Function Meter,2 Set of phase indicating lamps with Single Pole MCB,2 Set of ON / OFF indicating lamps with Single Pole MCB.BUS BARS:-160 Amps. TP&N aluminium bus bars.OUT GOINGS:-2 Nos. 63 Amps. FP MCCB thermal magnetic release (25 KA),7 Nos. 32 Amps. FP MCCB thermal magnetic release (25 KA),2 Nos. 32 Amps. DP MCB,2 Nos. Space & Spare.MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 242 | Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A only.Note:- All panel will be TTA Panel. INCOMER:-1 No 200 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking Capacity,1 No 32 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking Capacity METERING :- 2 No. Multi Function Meter,2 Set of phase indicating lamps with Single Pole MCB,2 Set of ON / OFF indicating lamps with Single Pole MCB.BUS BARS:-250 Amps. TP&N aluminium bus bars.OUT GOINGS:-8 Nos. 32 Amps. FP MCCB thermal magnetic release (25 KA),2 Nos. 32 Amps. DP MCB ,2 Nos. Space & Spare.MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 243 | Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A only.Note:- All panel will be TTA Panel. INCOMER:-1 No 63 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking Capacity,1 No 32 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking Capacity.METERING :-1 No. Multi Function Meter,2 Set of phase indicating lamps with Single Pole MCB,2 Set of ON / OFF indicating lamps with Single Pole MCB.BUS BARS:-100 Amps. TP&N aluminium bus bars.OUT GOINGS:-4 Nos. 32 Amps. FP MCB (10 KA),2 Nos. 32 Amps. DP MCB,2 Nos. Space & Spare.MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 244 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each |
| 245 | Supply and burring of Safe Earthing Electrode T-39 (Hot-Dip Galvanized), Length up to 2000mm, outer pipe 76mm inner Dia 50mm terminal Dia 12 mm ,outer GI pipe of 16 SWG and inner GI pipe of 12 SWG with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonary housing. (From electrode terminal to switch board, cost of 25 X 3 GI. Strip will be extra) |
| 246 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 247 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 248 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 249 | Supply installation testing and commissioning of Pure Server based CPU,Digital IP ready EPABX system traditional circuit-switched technology, run on 36 V. DC.configured for: 16 Analogue Extensions Number /FXS ports 24 Digital Extensions lines 08 Analogue Junction/FXO ports (For external lines) 01PRI Card for minimum 30 channel. Supported PRI, E1, E&M, GSZZ Gateway Types supported - FXS Level DID on PRI (Service Provider) (optional) CLIP Facility on Analog Trunks and Extensions Expandable up to 64 lines. |
| 250 | Providing, laying, connecting and testing of multi-core telephone armoured cable of conductor size 0.6mm dia annealed copper conductor PVC insulated PVC sheathed jelly filled (as per DOT specification) cable along wall or ceiling or through existing pipe.5 Pair telephone cable |
| 251 | Providing, fixing connecting and testing of under noted size of solderless telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted.10 pair tag block |
| 252 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20mm dia PVC conduit |
| 253 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25mm dia PVC conduite. |
| 254 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.32mm dia PVC conduite. |
| 255 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required 1 or 2 Module (75mmX75mm) |
| 256 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as requiredTelephone socket outlet |
| 257 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required TV antenna socket outlet |
| 258 | RJ-45 Data Socket outlet |
| 259 | RJ-45 Data Socket outlet |
| 260 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable |
| 261 | Providing, laying, connecting and testing of unarmoured TV cable RG-6 PVC insulated cable along wall or ceiling or through existing pipe. |
| 262 | Supply , Installtion , Testing and Comissioning of IP Landline Speaker Phone With Caller Id. |
| 263 | Supply , Installtion , Testing and Comissioning of 24 PORT Access Switch Layer 3 |
| 264 | S/F of 6U Wall Mount following size Rack with front glass door & lock arrangement with suitable size of Fan and ACD power socket. For outdoor with IP 66 Protection |
| 265 | Supply , Installtion , Testing and Comissioning of CAT 6A patch cord 3 feet . |
| 266 | Supplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes:2 Pair (4 core) |
| 267 | Supply installation testing and commissioning of Pure Server based CPU,Digital IP ready EPABX system traditional circuit-switched technology, run on 36 V. DC.configured for: 16 Analogue Extensions Number /FXS ports 24 Digital Extensions lines 08 Analogue Junction/FXO ports (For external lines) 01PRI Card for minimum 30 channel. Supported - PRI, E1, E&M, GSM Gateway Types supported - FXS Level DID on PRI (Service Provider) (optional) CLIP Facility on Analog Trunks and Extensions Expandable up to 64 lines. |
| 268 | Providing, fixing connecting and testing of under noted size of solderless telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted.10 pair tag block |
| 269 | Supply , Installtion , Testing and Comissioning of Landline Speaker Phone With Caller Id. |
| 270 | Supply , Installtion , Testing and Comissioning of 12 PORT Access Switch Layer 3 |
| 271 | Supply , Installtion , Testing and Comissioning of CAT 6A patch cord 3 feet . |
| 272 | Supply , Installtion , Testing and Comissioning of CAT 2 pair telephone line cord 1.5 feet . |
| 273 | Supply , Installtion , Testing and Comissioning of Landline Speaker Phone With Caller Id. |
| 274 | Laying of one number PVC insulated and PVC sheathed / XLPE power Cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Up to 35 sq.mm. MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 275 | Laying of one number PVC insulated and PVC sheathed / XLPE power Cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq.mm. and upto 185 sq.mm. MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 276 | Laying of one number PVC insulated and PVC sheathed / XLPE power Cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 35 sq.mm. and upto 95 sq.mm. MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 277 | Laying of one number PVC insulated and PVC sheathed / XLPE power Cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 185 sq.mm. and up to 400 sq.mm. MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 278 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Up to 35 sq.mm. MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 279 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Above 95 sq.mm. and upto 185sq.mm. MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 280 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Above 35 sq.mm. and upto 95 sq.mm. MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 281 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Above 185 sq.mm. and up to 400 sq.mm. MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 282 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Upto 35 sq. mm (clamped with 1mm thick saddle |
| 283 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp |
| 284 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp |
| 285 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 286 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 287 | Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3.5 x 185 sq.mm.MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 288 | Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 4 x 10 sq.mm. MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 289 | Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 2 x 10 sq.mm, MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 290 | Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3.5 x 185 sq.mm.MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 291 | Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3.5 x 50 sq.mm. MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 292 | Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3.5 x 50 sq.mm. MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 293 | Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3.5 x 150 sq.mm.MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 294 | Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3.5 x 35 sq.mm. MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 295 | Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3.5 x 300 sq.mm.MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 296 | Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3.5 x 240 sq.mm.MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 297 | Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3 x 6 sq.mm.,MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 298 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 2 X 10 sq. mm (19mm) |
| 299 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3½ X 185 sq. mm (57mm) |
| 300 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 4 X 10 sq. mm (25mm) |
| 301 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3½ X 125 sq. mm (25mm) |
| 302 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3.5 x 50 sq.mm(25mm) |
| 303 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 4 x 10 sq.mm(25mm) |
| 304 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3½ X 95 sq. mm (45mm) |
| 305 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3.5 x 150 sq.mm(50mm) |
| 306 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3.5 x 35 sq.mm(25mm) |
| 307 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 2 X 6 sq. mm (19mm) |
| 308 | 'Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3½ X 240 sq. mm (62mm) |
| 309 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3½ X 300 sq. mm (70mm) |
| 310 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 100mm dia |
| 311 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 150 mm dia |
| 312 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 250 mm dia |
| 313 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 300 mm dia |
| 314 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 100 mm dia |
| 315 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 316 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm wide x 50 mm depth x 1.6 mm thickness. |
| 317 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm wide x 50 mm depth x 1.6 mm thickness. |
| 318 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm wide x 50 mm depth x 1.6 mm thickness. |
| 319 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm wide x 50 mm depth x 1.6 mm thickness. |
| 320 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm wide x 50 mm depth x 1.6 mm thickness. |
| 321 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm wide x 50 mm depth x 1.6 mm thickness. |
| 322 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm wide x 50 mm depth x 1.6 mm thickness. |
| 323 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm wide x 50 mm depth x 1.6 mm thickness. |
| 324 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm wide x 50 mm depth x 1.6 mm thickness. |
| 325 | SITC of single spike air terminals of 10 mm dia. & 1000 mm length as required and as per site conditions. The air terminal shall be manufactured with aluminium & shall be as per IEC 62561-2. The air terminal shall be fixed with base plate arrangement.Make: JMV/Erico/ furse |
| 326 | Roof Conductor for Parapet & Mesh : Supply of 8 mm dia aluminium round conductor for air termination network at parapet and for making mesh at terrace level and shall meet the requirement of IEC 62561-2.Make: JMV/Erico/ furse |
| 327 | Supply of parapet & mesh conductor holder self drilled screw for holding 8 mm dia. round conductor (For metallic sheet). The conductor holder should be installed at every 1 mtr. The conductor holder shall be made with SS Z type metal shed holder and self drilled screw and washer & as per IEC 62561-4.Make: JMV/Erico/ furse |
| 328 | Bridging cable: SITC of 16sq.mm. copper cable along with lugs, having 500mm length & as per IEC 62561-1 so as to connect air termination rod with any metallic structure on the roof. Make: JMV/Erico/ furse |
| 329 | SITC of Universal Connector for making straight, Tee & Cross joint of 8 mm Aluminium Conductor to 8 mm dia Aluminium conductor on parapet wall, roof and vertical facade of masonery / glass / metallic work. Make: JMV/Erico/ furse |
| 330 | SITC of 8 mm dia aluminium round conductor for Down conductors to be installed on vertical wall, façade of masonary / glass / metalic work. It shall meet the requirements of IEC 62561-2.Make: JMV/Erico/ furse |
| 331 | SITC of Wall Conductor holder for holding 8 mm dia. round conductor (for RCC wall). The conductor holder should be installed at every 1 mtr. The conductor holder shall be made with clamp mounted on plastic base support & as per IEC 62561-4.(Part No. JMV/H8A800)Make: JMV/Erico/ furse |
| 332 | SITC of Test Clamp to disconnect the down conductor from the earth termination network for regular checks of the earth termination resistance value. (with enclosure). It shall meet the requirements of IEC 62561-2. Make: JMV/Erico/ furse |
| 333 | SITC of Expansion piece made of 8mm dia. Aluminium & as per IEC 62561-2 along with suitable connecting accessory. It shall be installed at every 20 mtr to maintain the flexibility to the conductor due to heat. Make: JMV/Erico/ furse |
| 334 | Supply of Lightning Strike counter Model: JMV 7D for counting the number of lightning strikes without any power supply. The Counter should be mounted on the Down Conductor. The Lightning Counter should be IP 68 rated enclosure suitable for external application. Make: JMV/Erico/ furse |
| 335 | SITC of single spike air terminals of 16/10 mm dia. & 2000 mm length as required and as per site conditions. The air terminal shall be manufactured with aluminium & shall be as per IEC 62561-2. The air terminal shall be fixed with necesarry base plate arrangementMake: JMV/Erico/ furse |
| 336 | Supply of Earthing termination made of copper-bonded rod of 10 feet length,14.2 mm dia. (Minimum copper bonding shall be 0.25mm) as per IS 3043, IEEE-80, NBC 2016 along with Earth enhancement material some with resistivity of 0.12 ohm-mtr, and complying IEC 62561-7 and Pit Cover complying IEC 62561-5 and other accessories as required and as per specification and other applicable codes.Make: JMV/Erico/ furse |
| 337 | SITC of 8 mm CBS Conductor laid at 600mm below the ground, as Required and as per specification and code of practice with Tee and Straight joint with SS Connector Make: JMV/Erico/ furse |
| 338 | SITC of 35 Ltr. Glass line Geyser with all accessories Make- HAVELLS/BAJAJ/USHA/CROMPTON. |
| 339 | Supply, Installation, testing and commissioning of 1000 KVA. 11/0.433 KV, 3 Phase, 50Hz, Dyn 11, Oil type, copper wound transformer with ON load tap changing arrangement on HV side in steps of +/- 2.50%, +/- 5% , having cable end boxes on HV side and 500 Amp. bus trunking arrangement on LV side complete with all accessories i/c first filling of filtered dehydrated oil and confirming to IS 2026 (Part 1 to Part 5) & as per specification attached complete in all respects as required at site.Note:Foundation work for transformer is not included in Electrical works it will come on Civil work. |
| 340 | Design, manufacturing, testing at works, supply of 1 No. 11KV, 630A, 21kA/3 Sec Outdoor type, extensible SF6 gas insulated Ring Main Unit equivalent to Ringmaster RE6C+CE6 with 1 Nos. On Load Cable isolator and 1 No. Vaccum Circuit breaker enclosed in a stainless steel tank with self powered microprocessor based numerical relay and dedicated Ct's for protection of Transformer comple as required and as per specification |
| 341 | Providing and fixing HT danger notice plate 250 mm x 200 mm made of mild steel at least 2mm thick & vitreous enamelled white on both sides and with inscription in signal red colour on front side as required. |
| 342 | Supplying and Fixing of Fire buckets, round bottom made of G.I. Sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-charge. |
| 343 | Supplying and Laying of Rubber mat 1000 mm. Wide to withstand 11 KV dielectric strength as per latest IS 15652-2006 etc. as reqd. |
| 344 | Supply and fixing of fire extinguishers, ABC Type 9.00 kg. capacity(ISI Marked IS : 15683 & TAC approved) complete with initial charges and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 345 | Supply and fixing of CO2 type fire extinguishers, 4.50 kg. capacity(ISI Marked IS : 2878 & TAC approved) complete with initial charges and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 346 | Supply of 3 core stranded aluminium conductor 11KV grade XLPE (E) (Cross linked Polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cable confirming to IS : 7098 (part II with latest amendments). 300 sq. mm 3 core.MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 347 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required Above 120 sq. mm and upto 400 sq. mm.MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 348 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 120 sq. mm and upto 400 sq. mm.MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 349 | supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core 300 sqmm, XLPE aluminium conductor cable of 11 KV grade as required |
| 350 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core 300 sqmm, XLPE aluminium conductor cable of 11 KV grade as required : |
| 351 | Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A only. Note:- All panel will be TTA Panel. Main Panel will be of PCC type panel. INCOMER:-1 No 1600 Amp. 4P EDO ACB of 50KA (Ics=Icu) Breaking Capacity,1 No. Multi Function Meter.1 No. CT FOR APFC PANEL,1 Set of phase indicating lamps with Single Pole MCB.1 Set of ON / OFF indicating lamps with Single Pole MCB,1 Set 50,50N,51,51N,27,32,49,59,86,95 CT's control.BUS BARS:-2000 Amps. TP&N aluminium bus bars OUT GOINGS:-1 Nos. 500 Amps. FP MCCB thermal magnetic release (35 KA),2 Nos. 320 Amps. FP MCCB thermal magnetic release (35 KA),3 Nos. 200 Amps. FP MCCB thermal magnetic release (35 KA),2 Nos. 160 Amps. FP MCCB thermal magnetic release (35 KA),2 Nos. 125 Amps. FP MCCB thermal magnetic release (35 KA),5 Nos. 63 Amps. FP MCCB thermal magnetic release (35 KA),4 Nos. 32A DP MCB (10KA).,2 Nos. Space & Spare.MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 352 | SITC APFC Panel of 300 KVAR capacity suitable for operation on 415 + 5% Volt, 3 Phase, 50Hz, AC supply, having MPP type, resin bounded, static 5,10,15,25 KVAR capacitors (without oil) in tier formation complete with following TPN MCCB as incomer of the panel, 10 step microprocessor based power factor controller relay capable to select the rating from 1 KVAR to multiples thereon up to max rating of the panel, current limiting contactors for each capacitors protected with MCBs, Ammeter (Analogue type) with CTs, Voltmeter (Analogue type) selector switches indicating lights, cooling fans for panel, earthing the panel with 2 Nos. 25mm x 5mm thick GI steel flat from existing earth bar, connection of APFC panel with suitable size 3.5 core aluminium conductor armoured XLPE cable from main LT panel (maximum length of cable 10 mtrs.) and compression glands etc. as reqd. The panel should have provision of timer based circuit in APFC relay to switch ON and OFF the static part automatically as and when requried. Capacity of Static capacitors should be accommodated from the overall rating of the panel and should be designed to switch in independently. The panel should be manufactured with 1.6mm thick CRCA sheet duly powder coated.Incoming:-One (1) No 500 Amp. 4P MCCB of 35 KA Breaking capacity BUS BAR:-1 Set of 600 Amps TPN Aluminium Bus Bars OUT GOING :-04 No. 125 Amps. TP MCCB (25 KA) (50KVAR),02 No. 63 Amps. TP MCCB (25 KA) - (25KVAR),02 No. 40 Amps. TP MCCB (25 KA) (15KVAR),02 No. 25 Amps. TP MCCB (25 KA) - (10KVAR) MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 353 | Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A only. Note:- All panel will be TTA Panel. Main Panel will be of PCC type panel. INCOMER:-1 No 320 Amp. 4P MCCB of 35KA (Ics=Icu) Breaking Capacity,1 No. Multi Function Meter.1 Set of phase indicating lamps with Single Pole MCB,1 Set of ON / OFF indicating lamps with Single Pole MCB.BUS BARS:-500 Amps. TP&N aluminium bus bars (35 KA) OUT GOINGS:-2 Nos. 200 Amps. FP MCCB,1 Nos. 100 Amps. FP MCCB,3 Nos. 40 Amps. FP MCCB,2 Nos. 32 Amps. DP MCCB,5 Nos. 16 Amps. DP MCB,2 Nos. Space & Spare MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 354 | Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A only. Note:- All panel will be TTA Panel. Main Panel will be of PCC type panel. INCOMER:-1 No 200 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking Capacity,1 No. Multi Function Meter.1 Set of phase indicating lamps with Single Pole MCB,1 Set of ON / OFF indicating lamps with Single Pole MCB.BUS BARS:-300 Amps. TP&N aluminium bus bars (25 KA) OUT GOINGS:-2 Nos. 100 Amps. FP MCCB,3 Nos. 63 Amps. FP MCCB,2 Nos. 40 Amps. FP MCCB,2 Nos. 32 Amps. DP MCB,2 Nos. Space & Spare. MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 355 | Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A only. Note:- All panel will be TTA Panel. Main Panel will be of PCC type panel. INCOMER:-1 No 63 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking Capacity,1 No. Multi Function Meter.1 Set of phase indicating lamps with Single Pole MCB,1 Set of ON / OFF indicating lamps with Single Pole MCB.BUS BARS:-100 Amps. TP&N aluminium bus bars (25 KA) OUT GOINGS:-3 Nos. 40 Amps. FP MCCB,3 Nos. 32 Amps. FP MCCB,2 Nos. Space & Spare.MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 356 | Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A only. Note:- All panel will be TTA Panel. Main Panel will be of PCC type panel. INCOMER:-1 No 160 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking Capacity,1 No. Multi Function Meter.1 Set of phase indicating lamps with Single Pole MCB,1 Set of ON / OFF indicating lamps with Single Pole MCB.BUS BARS:-200 Amps. TP&N aluminium bus bars (25 KA) OUT GOINGS:-2 Nos. 40 Amps. FP MCCB,8 Nos. 32 Amps. FP MCCB,2 Nos. Space & Spare. MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 357 | Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A only. Note:- All panel will be TTA Panel. Main Panel will be of PCC type panel. INCOMER:-1 No 63 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking Capacity,1 No. Multi Function Meter.1 Set of phase indicating lamps with Single Pole MCB,1 Set of ON / OFF indicating lamps with Single Pole MCB.BUS BARS:-100 Amps. TP&N aluminium bus bars (25 KA) OUT GOINGS:-3 Nos. 40 Amps. FP MCCB,5 Nos. 16 Amps. DP MCB,2 Nos. Space & Spare. MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 358 | Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A only. Note:- All panel will be TTA Panel. Main Panel will be of PCC type panel. INCOMER:-1 No 63 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking Capacity,1 No. Multi Function Meter.1 Set of phase indicating lamps with Single Pole MCB,1 Set of ON / OFF indicating lamps with Single Pole MCB.BUS BARS:-100 Amps. TP&N aluminium bus bars (25 KA) OUT GOINGS:-3 Nos. 32 Amps. FP MCCB,3 Nos. 32 Amps. DP MCB,5 Nos. 16 Amps. DP MCB,2 Nos. Space & Spare. MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 359 | Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A only. Note:- All panel will be TTA Panel. Main Panel will be of PCC type panel. INCOMER:-1 No 40 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking Capacity,1 No. Multi Function Meter.1 Set of phase indicating lamps with Single Pole MCB,1 Set of ON / OFF indicating lamps with Single Pole MCB.BUS BARS:-60 Amps. TP&N aluminium bus bars (25 KA) OUT GOINGS:-4 Nos. 32 Amps. FP MCCB,15 Nos. 16 Amps. DP MCB,2 Nos. Space & Spare. MAKE:-HAVELLS, C&S,LEGRAND,ABB,SEIMENS |
| 360 | Supply of hot dip galvanised steel OCTAGONAL POLE, Height=7m, Top OAF= 70 mm, Bottom OAF-130, Thickness - 3 mm,Base Plate - 220x220x12 mm , PCD - 220 mm |
| 361 | Supply of foundation accessories for 7 mtr pole set-Each set consists of 4 nos. of M20x700 J bolts plus 10% templates |
| 362 | Supply of 1000 mm Galvanized SINGLE Arm bracket , Standarad Type made of 48.3/32 mm OD pipe |
| 363 | Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body and lenses suitable for 90Watt. to 100 Watt and Confirming to IP66 protection having Company LOGO Engraved complete in all respect with 4000-5000 system lumens High Power LED with lenses, >110lm/W, PF>0.95, THD <10% at full load, CRI>70, Avg Life Class 50000Hrs@L70,fitting itself suitable for 60-65mm OD pipe.MAKE:-HAVELLS, ,PHILIPS,OSRAM |
| 364 | Supply and fixing of All in one LED Solar Street light Fitting with mandatory driver set for 60Watt. Confirming to IP66 protection having. Complete in all respect.MAKE:-HAVELLS, ,PHILIPS,OSRAM |
| 365 | Supply of hot dip galvanised steel OCTAGONAL POLE, Height=4mtr, Top OAF= 70 mm, Bottom OAF-130, Thickness - 3 mm,Base Plate - 200x200x12 mm , PCD - 220 mm. |
| 366 | Supply of foundation accessories set-Each set consists of 4 nos. of M16x450 J bolts plus 10%templates |
| 367 | Supply of 600 mm Galvanized SINGLE Arm bracket , Standarad Type made of 48.3/32 mm ODpipe |
| 368 | Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body and lenses suitable for 60Watt. and Confirming to IP66 protection having Company LOGO Engraved complete in all respect with 4000-5000 system lumens High Power LED with lenses, >110lm/W, PF>0.95, THD <10% at full load, CRI>70, Avg Life Class [email protected]:-HAVELLS, ,PHILIPS,OSRAM |
| 369 | Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required |
| 370 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 4.5 metre and upto 6.5 metre |
| 371 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 6.5 metre and upto 8.0 metre |
| 372 | Supply and fixing of 8 to 10 Watt LED bollard luminaire with driver set confirming to IP 65 protection complete in all respect.MAKE:-HAVELLS, ,PHILIPS,OSRAM |
| 373 | Supply & fixing of 16 mtr High mast shaft with 8 Nos. 250W LED light of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 3 mm. Top dia minium 150 mm, Bottom dia 310 mm base plate 25 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 luminaries & its control gear boxes 0.75 HP power tool moter, 3 point suspension system with steel wire rope 6 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc, completee in all respect.MAKE:-HAVELLS, ,PHILIPS,OSRAM |
| 374 | Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. 1 output per phase and suitable for single phase supply |
| 375 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 376 | Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required 32 mm dia |
| 377 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Up to 35 sq.mm. |
| 378 | Supply of following size of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment . Size 4 sq.mm x 4 core.MAKE:HAVELLS,POLYCAB,FINOLEX,KEI |
| 379 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 2 X 6 sq. mm (19mm) |
| 380 | Providing ,storing ,handling ,shifting ,installation,testing and commissioning of halon free portable fire Extinguishers as described below: P & F CO2 Portable & Trolley fire extinguisher,4.5kg Carbon-Dioxide type Flat base Horn including Valve high Pressure Rubber wire Braided discharge Hose of not less than 10mm dia & complete in all respects including initial fill with CO2 Gas confirming to IS:15222 |
| 381 | Providing ,storing ,handling ,shifting ,installation,testing and commissioning of halon free portable fire Extinguishers as described below: P&F ABC MAP-90% Powder based fire extinguisher,Applicabe fire class A,B & C,EPDM Rubber Hose NRV Valve and Helium leak Detection Tested,Internal Coated-Epoxy Powder and external pure polyester powder Coated(UV resistant),IS 15683:2006 Marked Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail