| 1 | Supply of Microprocessor based Automatic traffic signal controller with housed in a water proof, dust proof & dust tight cabinet with internal locking arrangement, Police panel etc, incorporating the following-minimum 115 trong plans & 12 phases, 7day clock, with 16 groups with minimum 48 lines with conflict management facilily and GPS clock system. |
| 2 | Installation, testing and commissioning of all types of ATC controller. |
| 3 | Sealing of controller with bitumen/foam for achieving IP 55 profection |
| 4 | supply of digital count down timer for ATC Signal Junctions (EN 12966) Graphic Type. |
| 5 | Installation, and commissioning of countdown timer for ATC Signal Junction. |
| 6 | Providing, Laying and Jointing HDPE Pipes of PE-80 grade and PN-6 class with butt joints etc complete as specified and directed 160 mm Dia (OD) |
| 7 | Supply of single 50 mm (OD) 37 mm (ID) double walled corrugated High Density Poly Ethylene (HOPE) Pipes conforming to the 15. 16205 (Part-24) Including supply of necessary sockets, couplings etc |
| 8 | Laying 50 mm (OD) 37mm (ID) double walled corrugated High Density Poly Ethylene (HDPE) Pipes including pull wire along with necessary socials, couplings etc as per drawing no. RT-NATC-32A & RT-NATC-3.2B |
| 9 | Supply of 50 mm Dia Class 'A` G.I. pipe including Supply of necessary acomssones suct as G.I. couplers etc. |
| 10 | Laying of 50 mm Dia Class 'A'G.I. pipe, with provision of Pull Boxes etc as por drawing no. RT-NATC-3.2A & RT-NATC-3.2B |
| 11 | Supply of Galvanised Iron Class B Traffic Signal straight pole of 6 mtr height as per Specification |
| 12 | Fabrication Supply of New type LED cantiliver Traffic Signal pole of GI ERW square pipe including 6 Nos of LED Modules, fatres, control units, drivers, rotays, wiros cables ecessary accessories and as per the Technical specifications and drawings |
| 13 | Installation & Commissioning of New type LED cantitiver Traffic Signal pole including Transportation from SICOM Depot to signal location (excluding founitarion) |
| 14 | Construction of foundation for New type LED cantiver Traffic Signal pole including foundation bolts as per technical specification and drawing |
| 15 | Supply of power supply box 600mm x 400mm x 300mm (HXWXC), with canopy made in welded construction 17 of SS 304 material having sheet of thickness 1 Gren with 1P 55 protection as per technical specification and asper requirement of power supply authority |
| 16 | Installation & commeskoning of power supply box |
| 17 | Supply of 300 mm dia single source LED retrofit Red (blow) as per Specification |
| 18 | Supply of 300 mm dia single source – LED – retrofit Amber (blow) as per specification. |
| 19 | Supply of 300 mm dia single sourc-LED-Green (arrow-/U-Tum) EN-12368 as per Specification |
| 20 | Supply of Polycarbonate LED Signal head housing 300 mm dia as per ATC Technical specification and drawing alongwith brackets & accessories etc (For all type of LED Retrofit) |
| 21 | Installation of Polycarbonate LED Signal aspect of 300 mm dia on standard traffic signal straight pole |
| 22 | Installation of Polycarbonate LED Signal aspect of 300 mm dia. On standand traffic signal cantilever pole |
| 23 | Supply of XLPE insulated -2.5 Sq.mm 3 core copper conductor |
| 24 | Supply of XLPE insulated-1.5 Sq.mm 8 core copper conductor |
| 25 | Supply of XLPE insulated-1 sq.mm. 16 core copper conductor |
| 26 | Laying of signal cables (all types including communication cables with multi pairs as described above) in trenches, existing ducts / G.I.Pipes including ferruling testing etc. but excluding any cable joint excavation etc. |
| 27 | Excavation of Vench for traffic signals and VIMS boards cables and conduiting as per requirertient of the signal 29ndien up to the depth of 1000mm below the ground surface and width 500men in the Camage way (Asphat Mastic Asphalt paver block) including refilling of the trench in carriage way and removal of deteris as per the BMC guidelinas |
| 28 | Excavation of trench for traffic signals and VIMS boards cables and conduiting as per requirement of the signal uretion up to the depth of 600mm bellow the ground surface and width 500mm in the footpath/soft soil Iincluding refilling of the trench in footpath and removal of debris as per the BMC guidelines |
| 29 | Excavate and install brick built or equivalent sectional chamber to be 450mm (LJX 450mm (B) X 600 mm(D) to tie into proposed 120 mm ducts/55mm GI Pipe in footpath include permanent reinstatement and backhtmaterial as per MCGM technical specification and drawing no. RT. 14 17. |
| 30 | Erecting straight pole in pole foundation of concrete M20 grade circular in shape of depth 1.3m below and/or above ground level having dia. Of 300mm only as per technical specification and drawing no RT-14.25 |
| 31 | Construction of signal controller foundation upto 600mm height above ground level and 600 mm below ground level on C. C. M20 grade pedestal, having size (LXBXH) with fling of SS304 nut bolts for controller cabinet & Power supply box cabinet as per RMC technical specification and drawing no. RT- 14.30 etc. complete |
| 32 | Supply, installation & Testing Chemical earthing which includes Chemo MF Earthing electrodies field with SSC compound, seal from both the end having dia 80 mm length 1000mm, terminal 506 mm, MOC-SDGI soil resistivity improvement powder with moister booster compound by manually digging process fixing of FRP marthing chamber cover, connection of earthing Pit to grip with each other & accessories le cables, lux, nuts, bots Gl strips (25X3) 1 mtr etc. as directed by engineer |
| 33 | Supplying installing, testing & commissioning of 1400 VA Digital pure sine wave inverter based on IGBT technology single phase 230V, 50 Hz completa as per specification no AP-INV (Without batteries) (3-6-3/67) |
| 34 | Supplying and erecting 12 V/150AH TUBULAR Battery with battery terminal wire, duly charged complete with 36 monthe warranty complete (3-8-4/69) |
| 35 | Supplying battery cabinet suitable for UPS |
| 36 | Supply & installation of FRP Chamber Cover size 510 X 510 X35 mm as per EN 124:2004 for 25 MT load capacity |
| 37 | Supply & installation of FRP Chamber Cover Frame of size 620 (L) X 620(B) X72 (W) mm suitable of FRP cover size 510 X 510 X45 mm as per EN 124:2004 for 25 MT load capacity |
| 38 | Supplying and erecting FRP box of size 300 x 200 x125 mm , 2.7 mm thick complete on pole /wall as per specification No. CB-SB |
| 39 | Supplying and laying of multicore flexible copper conductor, PVC insulated & sheated, ISI wire of 0.5 sq.mm. A) 6 core wire on GI bearer wire No. 16 SWG complete erected with required size of porcelain/PVC reel insulators & 18 SWG GI binding wire |
| 40 | Supply and fixing 15 Amp PVC connector/ cat-6 cable connector |
| 41 | Replace 6\\" size hose clip Please Enable Macros to View BoQ information |