| 1 | Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. a) All kinds of soil. |
| 2 | Earthwork in excavation by mechanical means (Hydraulic excavator) in trenches for foundation, drains, pipes etc. (not exceeding 1.5m in width) and for shafts, wells, cesspits and the like not exceeding 10sqm on Plan, including dressing of sides and ramming of bottoms lift upto 1.5m, including getting out the excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 mtr. a) All kinds of soil. |
| 3 | Providing and laying cement concrete of specified grade including curing but excluding the cost of centering and shuttering. All work upto plinth level with: a) 1:5:10 (1 cement:5 coarse sand:10 graded stone aggregate 40mm nominal size). |
| 4 | Providing and laying cement concrete of specified grade including curing but excluding the cost of centering and shuttering. All work upto plinth level with: a) 1:3:6 (1 cement:3 coarse sand:6 graded stone aggregate 20mm nominal size) |
| 5 | Brick work with common burnt clay (non modular) bricks of class designation 7.5 in foundation and plinth including curing in cement mortar 1:6 (1 cement:6 coarse sand). |
| 6 | Extra for brick work with common burnt clay bricks / cement concrete bricks in superstructure above plinth level upto floor five level. |
| 7 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centring ,shuttering, finishing and reinforcement. All work upto plinth level with: a) 1:1.5:3 (1 cement:1.5 coarse sand:3 graded stone aggregate 20mm nominal size). |
| 8 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. a) 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with:a) 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing inposition and binding all complete above plinth level: a) Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 11 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. a) 50mm thick with 20 mm nominal size stone aggregate. |
| 12 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 13 | Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete. |
| 14 | 12mm Cement plaster of mix:a) 1 : 6 ( 1 cement : 6 fine sand) |
| 15 | 15mm Cement plaster on the rough side of single or half brick wall of mix: a) 1 : 6 ( 1 cement : 6 fine sand) |
| 16 | 6mm cement plaster to ceiling of mix. 1:3 (1 cement:3 fine sand). |
| 17 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 18 | Centering and shuttering including strutting, propping etc.and removal of form work for : |
| 19 | Foundation, footings, bases of columns etc. for mass concrete. |
| 20 | Suspended floors, roofs, landings, balconiesand access platform. |
| 21 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 22 | Columns, pillars, piers, abutments, posts and struts. |
| 23 | Edges of slabs and breaks in floors and walls under 20cm wide. |
| 24 | Providing and fixing strips in joints of terrazzo/ cement concrete floors. A) Glass strips : i) 40 mm wide and 4 mm thick |
| 25 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately). a) Sal Wood. |
| 26 | Providing and fixing 30mm panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately). a) Second class deodar wood |
| 27 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. a) Particle Board 12mm thicki) Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS : 3087 marked |
| 28 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. a) 4 mm thick glass pane (weighing not less than 10 kg/sqm). |
| 29 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete: i)2nd class deodar wood. A) 50 x 12 mm |
| 30 | Providing and fixing 30mm glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. A) Second class deodar wood. |
| 31 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : a) Second class deodar wood |
| 32 | Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications: a) Painting steel work with deluxe multi surface paint of required shade to give an even shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primerapplied @ 0.80litre/10sqm of approved brand and manufacture |
| 33 | Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications: a) Painting wood work with deluxe multi surface paint of required shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.75litre/10sqm of approved brand and manufacture |
| 34 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 35 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 36 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 37 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. A) Fixed to openings / wooden frames with rawl plugs screws etc. |
| 38 | Providing and fixing aluminium handles lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. |
| 39 | 100 mm |
| 40 | 125 mm |
| 41 | Providing and fixing aluminium tower bolts lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 42 | 250x10 mm |
| 43 | 150x10 mm |
| 44 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : a) 300x16 mm |
| 45 | Wiring for light point, fan point/exaust fan point / call bell point with 1.5 sq mm FRLS PVS insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI Box earthing the point with 1.5 sq. mm FRLS PVS insulated copper conductor single core cable etc. as required. (LMR) |
| 46 | Supply and fixing of Exhaust fan / ceiling fans 230 V 50 Hz ceiling fan with double ball of approved brand (1400mm ceiling fan). (Usha/Orient /Standard / Havels) (1400mm) (LMR) |
| 47 | Supply of LED bulb 9 W (LMR) |
| 48 | Supply & fixing 25mm square core aluminium able as req. (LMR) |
| 49 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes a) 110 mm diametre |
| 50 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. a) Bend 87.5° i) 75 mm bend |
| 51 | Providing and laying cement concrete of specified grade including curing but excluding the cost of centering and shuttering. All work upto plinth level with: a) 1:3:6 (1 cement:3 coarse sand:6 graded stone aggregate 20mm nominal size) with 30% boulders. |
| 52 | Add cost for SAMAGRA logo (LMR) |
| 53 | Carriage of the following materials by Mechanical Transport / Heal Load from source to site of work incl. loading, unloading and stacking complete :- |
| 54 | Sand from Billawar for an average lead of 60.00 Km. by M.T. & 500 mtr. by H.L. |
| 55 | Stone aggregate below 40mm nominal size from Billawar for an average lead of 60.00 Km. by M.T. & 500 mtr. by H.L. |
| 56 | Stone aggregate 40mm nominal size & above from Billawar for an average lead of 60.00 Km. by M.T. & 500 mtr. by H.L. |
| 57 | Stones / boulders for an av. Lead of 10.00 Km. by M.T. & 500 mtr. by H.L. |
| 58 | Bricks from Kathua for an average lead of 95.00 Km. by M.T. & 500 mtr. by H.L. Please Enable Macros to View BoQ information |