| 1 | APPENDIX A-BUILDING PROPER(Civil work) |
| 2 | 2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared |
| 3 | 2.33.1:Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth |
| 4 | 2.33.2:Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth |
| 5 | 2.18.2:Close timbering over areas including strutting, shoring and packing cavities (wherever required) etc. complete ( Measurements to be taken of the face area timbered):Depth exceeding 1.5 m but exceeding 3 m |
| 6 | 2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock |
| 7 | 2.9.1:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock |
| 8 | 2.9.3:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Hard rock (blasting prohibited) |
| 9 | 2.26.2:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock |
| 10 | OD349728/2025-2026:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) using PPC cement with more than25% fly ash etc complete as per GRIHA specifications. |
| 11 | OD349742/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Additional cement required as per mix design shall be considered by the bidder while quoting. Excess or less cement used as per design mix is not payable or recoverable separately. All work up to plinth level using PPC cement with 15% fly ash etc complete as per GRIHA specification. |
| 12 | OD349726/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Additional cement required as per mix design shall be considered by the bidder while quoting. Excess or less cement used as per design mix is not payable or recoverable separately. All work above plinth level up to floor V level using PPC cement with 15% fly ash etc complete as per GRIHA specification. |
| 13 | 5.38:Extra for R.C.C. /B.M.C/R.M.C. work above floor V level for each four floors or part thereof. |
| 14 | 4.14:Extra for concrete work in superstructure above V level for each four floors or part thereof. |
| 15 | 2.35.1.1:Diluting and injecting chemical emulsion for POST -CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion):Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete:With Chlorpyriphos /Lindane E.C. 20% with 1% concentration |
| 16 | 2.34.1:Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos / Lindane emulsifiable concentrate of 20% |
| 17 | 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 18 | 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers |
| 19 | 5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts |
| 20 | 5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 21 | 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 22 | 5.9.17:Centering and shuttering including strutting, etc. and removal of form for:Cornices and mouldings. |
| 23 | 5.9.13:Centering and shuttering including strutting, etc. and removal of form for:Vertical and horizontal fins individually for forming box louvers band, facias and eaves boards |
| 24 | 5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide |
| 25 | 5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) |
| 26 | 5.9.19:Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges |
| 27 | 5.9.4:Centering and shuttering including strutting, etc. and removal of form for:Shelves (Cast in situ) |
| 28 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 29 | 5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more |
| 30 | OD349743/2025-2026:Laterate masonry with neatly dressed laterate stone of size 40x20x15 cm or nearest size in cement mortar 1:6 ( 1 cement : 6 coarse sand ) using PPC cement with more than 25% fly ash for foundation and basement including all cost of materials, labour charges etc as per GRIHA specifications. |
| 31 | OD349736/2025-2026:Laterate masonry with neatly dressed laterate stone of size 40x20x15 cm or nearest size in cement mortar 1:6 ( 1 cement : 6 coarse sand ) using PPC cement with more than 25% fly ash for super structure above plinth level up to floor two level including all cost of materials, labour charges etc as per GRIHA specifications. |
| 32 | OD349740/2025-2026:Laterate masonry with neatly dressed laterate stone of size 40x20x15 cm or nearest size in cement mortar 1:6 ( 1 cement : 6 coarse sand )using PPC cement with more than 25% fly ash for superstructure above floor two level upto floor five level including all cost of materials, labour charges etc as per GRIHA specifications. |
| 33 | OD349723/2025-2026:Laterate masonry with neatly dressed laterate stone of size 40x20x15 cm or nearest size in cement mortar 1:6 ( 1 cement : 6 coarse sand) using PPC cement with more than 25% fly ash for superstructure above floor five level upto floor nine level including all cost of materials, labour charges etc. |
| 34 | OD349722/2025-2026:Solid masonry using pre cast solid blocks with more than 40% fly ash (factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 20cm in : CM 1:6 ( 1 cement : 6 coarse sand) using PPC cement with more than 25% fly ash etc complete as per GRIHA specifications. |
| 35 | OD349724/2025-2026:Solid masonry using pre cast solid blocks with more than 40% fly ash (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level up to floor five level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) using PPC cement with more than 25% fly ash etc complete as per GRIHA specifications. |
| 36 | OD349731/2025-2026:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) using PPC cement with more than 25%flyash etc complete as per GRIHA specification |
| 37 | OD349717/2025-2026:Filling the sunken slab with sand with all cost etc complete as per specification. |
| 38 | OD349712/2025-2026:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).First class teak wood |
| 39 | 50.9.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood |
| 40 | 50.9.4.1:Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood |
| 41 | 50.9.3.1:Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood |
| 42 | OD349738/2025-2026:Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Using Anjili wood / jack wood 30 mm thick shutters. Float glass panes 4.0 mm thickness meeting GRIHA compliance of overall value VLT>65%, SHGC<0.54, U-Value-3.3W/m2 |
| 43 | OD349734/2025-2026:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels,plate., including welding, grinding, buffing, polishing and making curvature (wherever required) etc complete, i/c fixing the railing by drilling on window frames with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered )Stainless Steel Square Tube Grade 304 20mm size, 1.5mm thickness |
| 44 | 9.11.1:Extra for providing heavy sheet float glass panes instead of ordinary float glass in glazed doors, windows and clerestory window shutters. ( Area of opening for glass panes excluding portion inside rebate shall be measured)Extra for providing heavy sheet float glass panes instead of ordinary float glassin glazed doors, windows and clerestory window shutters. (Area of opening forglass panes excluding portion inside rebate shall be measured |
| 45 | 9.14:Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. ( Shutter area to be measured) |
| 46 | 9.141:Providing and fixing PVC Door Frame of size 50x47 mm with a wall thickness of 5 mm (±0.2mm), made out of single piece extruded PVC profile, with mitred cut joints and with 2 nos of PVC bracket of size 190 mm x 100 mm long arms of cross section size 35 x 15 mm & self driven self taping screws, the vertical door profiles to be reinforced with 40x20 mm M.S. rectangular tube of 0.8 mm, including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5 mm PVC frame strip with PVC solvent cement on the back of the profile. The door frame to be fixed to the wall using 8x100 mm long anchor fasteners complete, all as per manufacturer's specification and direction of Engineer-in--charge. |
| 47 | 9.142.1:35 mm thick factory made Solid panel PVC Door shutter, made out of singleNon decorative finish (matt finish) |
| 48 | 21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) |
| 49 | 21.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 50 | OD349739/2025-2026:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness meeting GRIHA compliance of overall value VLT>65%,SHGC<0.54,U-Value-3.3W/m2. |
| 51 | OD349737/2025-2026:Providing and fixing Fixed glazed shutters for existing door frames using 12 mm thick toughened glass panes with necessary screws. First class teak wood 35 mm thick with Fixed Glass. Toughened glass 12 mm thickness meeting GRIHA compliance of overall value VLT>65%, SHGC<0.54, U-Value-3.3W/m2. |
| 52 | OD349741/2025-2026:Providing and fixing glazed shutters for door using 12 mm thick toughened glass panes including ISI marked Double action hydraulic floor spring with stainless steel cover plate of required size with necessary screws.First class teak wood 35 mm thick For Main Entrance Doors. Toughened glass 12mm thickness meeting GRIHA compliance of overall value VLT>65%, SHGC<0.54, U-Value-3.3W/m2. |
| 53 | OD349720/2025-2026:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).First class teak wood |
| 54 | 25.1:Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminum extruded section shall be taken for purpose of payment |
| 55 | 25.2:Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin- Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub-head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories 1. Performance Laboratory Test for Air Leakage Test (-50pa to ? 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr? 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.? 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testing method for a range upto 2000 ml? 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm? 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test? Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml? |
| 56 | 25.3:Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement |
| 57 | 25.4:Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. |
| 58 | 26.22.1:Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length 1200 mm and secondaryintermediate cross-T of size 24x32 mm of length 600mm to formgrid module of size 600 x 600 mm, suspended from ceiling usinggalvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The workshall be carried out as per specifications, drawing and as per directionsof the Engineer-in-Charge.With 15 mm thick tegular edged light weight calcium silicate false ceiling tiles. |
| 59 | 21.7.1:Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fastners of 8 mm dia and 75 mm long bolt including providing aluminium - washers 2 mm thick 15 mm dia, at a staggered pitch of 200 mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete as per drawing and direction of Engineer -in-charge.Anodised aluminium sheet 2.5 mm thick (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 60 | 21.11.2:Providing and fixing stainless steel (SS 304 grade) adjustable friction window stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer - in-Charge complete.255 x 19 mm |
| 61 | 21.17:Providing and fixing anodised aluminium grill ( anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.(Only weight of grill to be measured for payment ). |
| 62 | 21.16.2:Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-Charge.Powder coated minimum thickness 50 micron aluminium |
| 63 | 9.136:Providing and fixing fire resistant door frame of section 143x57 mm having built in rebate made out of 16 SWG G.I. sheet ( zinc coating not less than 120 gm/ sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer -in-charge (Dash fastener to be paid for separately ). |
| 64 | 9.137:Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS : 3614 (Part - II), tested and certified as per laboratory approved by Engineer-in-Charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer -in-charge ( panneling to be paid for separately). |
| 65 | 9.53:Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 66 | 9.97.1:Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm |
| 67 | 9.106.2:Providing and fixing PTMT handles with necessary screws etc. complete.150x34x24 mm weighing not less than 26 gms |
| 68 | 50.9.15.2:Supplying and fixing 300 mm Aluminium aldrop |
| 69 | OD349725/2025-2026:Pad lock 65mm or nearest size (7 lever) best quality <br> |
| 70 | OD349719/2025-2026:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) using PPC cement with more than 25% fly ash etc complete as per GRIHA specification |
| 71 | OD349713/2025-2026:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster using PPC cement with more than 25% fly ash etc complete as per GRIHA specification |
| 72 | OD349718/2025-2026:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) using PPC cement with more than 25% fly ash etc complete as per GRIHA specification |
| 73 | OD349733/2025-2026:Laterate stone tile work for wall lining upto 10 m height with special adhesive over the existing wall surface with specified pattern as per architectural drawings and direction of engineer in charge, in line and levels, including pointing in white cement with an admixture of pigment to match the stone shade including cost and conveyance of material, labour, scaffolding charges etc complete. 10 mm thick (polished and machine cut edge) of 30 x 15 cm or nearest size first quality laterate stone tile of red colour and texture |
| 74 | OD349716/2025-2026:Extra for laterate stone wall lining on exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. |
| 75 | OD349727/2025-2026:Polishing on laterate or granite walls with one or more coats of high gloss stone varnish of approved brand and manufacture as per the direction of engineer-in-charge. |
| 76 | 13.24.1:Extra for plastering done on moulding cornices or architraves including neat finish to line and level:In one coat |
| 77 | 13.22:Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. |
| 78 | 22.5:Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 79 | 22.6:Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) |
| 80 | 10.25.2:Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 81 | 13.80:Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 82 | 13.85.3:Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With water thinnable cement primer on walls surface having VOC content less than 50 grams / litre |
| 83 | 13.83.2:Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats |
| 84 | 13.47.1:Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 85 | 12.63:Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittnce tested as per ASTM) C 1549 and ASTM C 1371 respectively), VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strictly as per manufacture's specifications and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc., washing with water all complete. The contractor shall give guarantee for the performance of SRI and also the durability of coating, all complete as per direction of Engineer - in- charge. |
| 86 | 13.62.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture . |
| 87 | OD349729/2025-2026:Providing and fixing I st quality ceramic glazed wall tiles with atleast 5% recycled content conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) using PPC cement with more than 25% fly ash and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 88 | OD349732/2025-2026:Providing and laying Ceramic glazed floor tiles with atleast 5% recycled content of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) using PPC cement with more than 25% fly ash, including pointing the joints with white cement and matching pigment etc., complete as per GRIHA specification. |
| 89 | OD349735/2025-2026:Providing and laying vitrified floor tiles with atleast 5% recycled content in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand) using PPC cement with more than 25% fly ash, including grouting the joints with white cement and matching pigments etc complete as per GRIHA specification.Size of Tile 600 x 600 mm. |
| 90 | OD349730/2025-2026:Providing and laying Vitrified tiles with atleast 5% recycled content in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand)using PPC cement with more than 25% fly ash, including grouting the joint with white cement & matching pigments etc complete as per GRIHA specification. Size of Tile 600x600 mm |
| 91 | OD349714/2025-2026:Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand) using PPC cement with more than 25% fly ash, joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete as per GRIHA specification. at all levels Granite of any colour and shade Area of slab upto 0.50 sqm |
| 92 | OD349711/2025-2026:Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand) using PPC cement with more than 25% fly ash, joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc complete as per GRIHA specification. at all levels. Area of slab over 0.50 sqm |
| 93 | 8.5:Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 94 | OD349721/2025-2026:Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) using PPC cement with more than 25% fly ash, laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge as per GRIHA specification. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 95 | 10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 96 | 10.3:Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts,locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer . |
| 97 | 10.5.2:Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6 mm for diagonal braces and central cross piece |
| 98 | OD349715/2025-2026:Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand) using PPC cement with more than 25% fly ash etc. complete as per GRIHA specification. Medium shade pigment using 50% white cement 50 % Grey cement |
| 99 | 50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 100 | 12.1.2:Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.80 mm thick with zinc coating less than 275 gm/m2 |
| 101 | 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 102 | 50.12.2.2:Providing & fixing Poly carbonate multi wall plain sheet 4 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/ self tapping screw of size (5.5x55mm) with EPDM seal complete upto any pitch in horizontal / vertical / curved surfaces, but excluding the cost of purlins, rafters, trusses and including cutting to size and shapes where ever required. |
| 103 | 12.7.1:Providing and fixing 15cm wide, 45 cm overall semi circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m2 |
| 104 | 10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 105 | 10.7:Providing and fixing ball bearing for rolling shutters. |
| 106 | APPENDIX B-WATER SUPPLY AND SANITARY WORKS(Civil work) |
| 107 | OD349785/2025-2026:Providing and fixing European type white glazed earthen ware floor mounted one piece water closet of approved make and size including seat cover, cistern with twin flush fittings (6/3L flush) ,nuts, bolts and gasket etc including making connection with the P/S trap, complete in all respect as per directions of Engineer-in-Charge. (Griha Certified product). Snow white One piece EWC of size 660x360x760 mm |
| 108 | OD349766/2025-2026:Providing and fixing European type white glazed earthen ware floor mounted one piece water closet of approved make and size including Soft close seat cover, cistern with twin flush fittings (6/3L flush), Wall mounted hinged handrail, nuts, bolts and gasket etc including making connection with the P/S trap, complete in all respect as per directions of Engineer-in-Charge. (Griha Certified product) to make the toilet functional for specially abled persons. Snow white One piece EWC of size 710x370x770 mm with Soft close seat cover, Wall mounted hinged handrail of size 600x100mm |
| 109 | OD349783/2025-2026:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass low flow pillar tap (Griha approved) capable of 6lpm @ 3.1 bar head flow rate or nearest flow to the head ratio, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 550x400 mm with 15 mm C.P. brass low flow pillar tap (Griha approved) |
| 110 | OD349768/2025-2026:Providing and fixing Counter Top wash basin with 15 mm C.P. brass low flow pillar tap (Griha approved) capable of 6lpm @ 3.1 bar head flow rate or nearest flow to the head ratio, 32 mm C.P. brass waste of standard pattern, including fixing over slab wherever require including all cost of labour, material and conveyance etc complete.:White Vitreous China Counter Top Wash basin size 550x400 mm Hindware, Cera or equivalent with a 15 mm C.P. brass low flow pillar tap (Griha approved) |
| 111 | OD349765/2025-2026:Providing and fixing wash basin with C.I. brackets, Elbow operated 15 mm low flow C.P. brass pillar cock / Clinical faucet (Griha approved) capable of 6lpm @ 3.1 bar head flow rate or nearest flow to the head ratio, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls to make the toilet functional foe special need persons:White Vitreous China Wash basin size 550x400 mm with Elbow operated 15 mm low flow C.P. brass pillar cock / Clinical faucet (Griha approved) |
| 112 | OD349782/2025-2026:Supplying and fixing sanitary fixtures for handicaped toilet SS Grab bar including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge as per GRIHA Specifications etc complete. Wall mounted grab bar 600 mm long made from SS with anti slip plastic coating |
| 113 | 17.80:Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx.size 610x390x370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer - in-charge. |
| 114 | 17.22:Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. |
| 115 | 18.21.1.1:Providing and fixing uplasticised PVC connection pipe with brass unions:30 cm length15 mm nominal bore |
| 116 | 18.21.2.1:Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length15 mm nominal bore |
| 117 | OD349756/2025-2026:Supplying and fixing Low flow Health faucet ABS body with wall hook and 1 metre SS braided rubber hose pipe (Griha approved) capable of 6lpm @ 3.1 bar head flow rate or nearest flow to the head ratio. |
| 118 | OD349746/2025-2026:Providing and fixing C.P. brass low flow long body bib cock ( Griha approved) capable of 6lpm @ 3.1 bar head flow rate or nearest flow to the head ratio of approved quality : 15 mm nominal bore |
| 119 | 17.76.1:Providing and fixing PTMT urinal cock of approved quality and colour.15 mm nominal bore, 80 mm long 42 mm high and 30 mm wide with BSP female threads weighing not less than 48 gms . |
| 120 | 17.16A:Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge |
| 121 | 17.10.1.1:Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm |
| 122 | 17.69.2:Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.Waste coupling 38 mm dia of 83 mm length and 77 mm breadth, weighing not less than 60 gms |
| 123 | 17.34.1:Providing and fixing toilet paper holder:C.P. brass |
| 124 | 17.28.2.1:Flexible pipe32 mm dia |
| 125 | 17.28.2.2:Flexible pipe40 mm dia |
| 126 | 17.31:Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 127 | 50.17.1.3:Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 128 | 50.17.1.1:Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 129 | 17.71:Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms |
| 130 | OD349754/2025-2026:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC SDR11) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes |
| 131 | OD349767/2025-2026:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC SDR11) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes |
| 132 | OD349759/2025-2026:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC SDR11) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work 25 mm nominal outer dia pipes |
| 133 | OD349764/2025-2026:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC SDR11) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work 32 mm nominal outer dia pipes |
| 134 | OD349745/2025-2026:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC SDR 11) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work 40 mm nominal outer dia pipes |
| 135 | OD349749/2025-2026:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC SDR 11) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work 50 mm nominal outer dia pipes |
| 136 | 50.18.7.3.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall |
| 137 | 50.18.7.4.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall |
| 138 | 50.18.7.6.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall |
| 139 | 50.18.8.2.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2 |
| 140 | OD349771/2025-2026:Supply and fixing SWR Type B sanitary concealed pipes and specials , jointing with solvent cement and fixing them on slabs, floors etc. in position for connecting various fixtures (including fixing of pipes in sleeves/ drilled holes before water proofing) and specials with brick or CC supports wherever necessary including cutting and chasing brick walls as required, making good the same with brick in CM 1:6 and plastering with CM 1:4, 12mm thick one coat, sealing joints between pipe and concrete, complete : 110 mm diameter |
| 141 | OD349779/2025-2026:Supply and fixing SWR Type B sanitary concealed pipes and specials , jointing with solvent cement and fixing them on slabs, floors etc. in position for connecting various fixtures (including fixing of pipes in sleeves/ drilled holes before water proofing) and specials with brick or CC supports wherever necessary including cutting and chasing brick walls as required, making good the same with brick in CM 1:6 and plastering with CM 1:4, 12mm thick one coat, sealing joints between pipe and concrete, complete : 75 mm diameter |
| 142 | OD349760/2025-2026:Supply , jointing and fixing SWR type B Sanitary exposed pipes and specials with good quality solvent cement and teflon tape and fixing the same to line, plumb and level on the sides of ducts, walls, suspended to slabs as the case may be by using slotted rails , U clamps, 8mm threaded rods and other required materials including drilling holes, making good the walls, cleaning etc. and finishing complete : 110 mm diameter |
| 143 | OD349744/2025-2026:Supply , jointing and fixing SWR type B Sanitary exposed pipes and specials with good quality solvent cement and teflon tape and fixing the same to line, plumb and level on the sides of ducts, walls, suspended to slabs as the case may be by using slotted rails , U clamps, 8mm threaded rods and other required materials including drilling holes, making good the walls, cleaning etc. and finishing complete : 75 mm diameter |
| 144 | OD349763/2025-2026:Supply , jointing and fixing SWR type A exposed pipes and specials for Rain water with good quality solvent cement and teflon tape and fixing the same to line, plumb and level on the sides of ducts, walls, suspended to slabs as the case may be by using slotted rails , U clamps, 8mm threaded rods and other required materials including drilling holes, making good the walls, cleaning etc. and finishing complete:110mm diameter |
| 145 | 50.18.9.17.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall |
| 146 | OD349769/2025-2026:Supply and Laying 160 diameter SN 4 sewage pipes conforming to IS15328, lowering into trenches, placing in position, aligning to line and levels and jointing with solvent cement including earth work excavation in all classes of soil, refilling the trenches and transporting excess soil as recommended by the site engineer, complete. (For sewer lines & Rain water harvesting). |
| 147 | 18.17.1:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore |
| 148 | 18.17.2:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore |
| 149 | 18.17.4:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore |
| 150 | OD349774/2025-2026:Supplying and fixing 25mm GM full way wheel valve <br> |
| 151 | 18.18.2:Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:20 mm nominal bore |
| 152 | 18.18.3:Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:25 mm nominal bore |
| 153 | OD349748/2025-2026:Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:32 mm nominal bore |
| 154 | OD349786/2025-2026:Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:50 mm nominal bore |
| 155 | OD349751/2025-2026:Providing and fixing forged brass Y-type strainer (screwed end) : 50 mm nominal bore |
| 156 | OD349776/2025-2026:Supplying and fixing 32mm GM full way wheel valve <br> |
| 157 | 18.53.1:Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore |
| 158 | 18.55.2:Providing and fixing PTMT stop cock of approved quality and colour.20 mm nominal bore, 89 mm long, weighing not less than 88 gms |
| 159 | 50.18.9.20.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow |
| 160 | 50.18.9.20.2:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63 dia 45 degree Elbow |
| 161 | 50.18.9.20.3:Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Door Elbow |
| 162 | 50.18.9.20.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Bend |
| 163 | 50.18.9.20.5:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee |
| 164 | 50.18.9.20.6:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63x63x63 mm dia Door Tee |
| 165 | 50.18.9.20.7:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia vent cowl |
| 166 | 50.18.9.21:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Elbow |
| 167 | 50.18.9.21.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend |
| 168 | 50.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow |
| 169 | 50.18.9.22.2:Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow |
| 170 | 50.18.9.22.3:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow |
| 171 | 50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend |
| 172 | 50.18.9.21.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75x75x75 mm dia Tee |
| 173 | 50.18.9.21.7:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl |
| 174 | 50.18.9.21.2:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow |
| 175 | 50.18.9.21.8:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia End cap |
| 176 | 50.18.9.21.3:Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia Door Elbow |
| 177 | 50.18.9.20.8:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia End cap |
| 178 | 50.18.9.20.10:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63x50 mm dia Reducer |
| 179 | 50.18.9.21.10:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75x63 mm dia Reducer |
| 180 | 50.18.9.22.12:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer |
| 181 | OD349752/2025-2026:110mm pvc door bend<br> |
| 182 | 50.18.9.22.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee |
| 183 | 50.18.9.22.6:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee |
| 184 | 50.18.9.22.8:Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl |
| 185 | 50.18.9.22.11:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling |
| 186 | 18.1.2:Providing and fixing Polyethelene - Aluminium - Polyethelene ( PE - AL- PE) Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80?C including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) eg. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 meter spacing. This includes testing of joints complete of joints complete as per direction of the Engineer -in-Charge. Internal work - Exposed on wall1620 (20 mm OD) pipe |
| 187 | 18.1.4:Providing and fixing Polyethelene - Aluminium - Polyethelene ( PE - AL- PE) Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80?C including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) eg. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 meter spacing. This includes testing of joints complete of joints complete as per direction of the Engineer -in-Charge. Internal work - Exposed on wall2532( 32 mm OD ) pipe |
| 188 | OD349762/2025-2026:Supply and fixing Inline rain water filter with ss304 screen with 90mm inlet and 63mm clear water outlet |
| 189 | OD349772/2025-2026:Supplying and fixing PVC Multi Floor Trap 110mmx75mm or nearest size without Jali including cutting open, boring through RCC slabs and making good the damages. |
| 190 | OD349747/2025-2026:Supplying and fixing PVC Nahni / Floor Trap 110mmx75mm or nearest size without Jali including cutting open, boring through RCC slabs and making good the damages. |
| 191 | OD349780/2025-2026:Supplying and fixing PVC Multi Floor Trap with end cap 110mmx75mm or nearest size without Jali including cutting open, boring through RCC slabs and making good the damages. |
| 192 | OD349750/2025-2026:Providing and fixing SS grating of approved quality. Rectangular type with openable circular lid : 150 mm nominal size square 100 mm diameter of the inner hinged round grating |
| 193 | 19.4.1.1:Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 194 | 18.32.1:Constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C.I. surface box 100x100x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S (non modular) bricks of class designation 7.5 |
| 195 | 19.7.1.1:Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 196 | 19.8.1.1:Extra for depth for manholesSize 90x80 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5 |
| 197 | 18.77:Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. |
| 198 | 18.76.1:Cutting holes up to 30x30 cm in walls including making good the same:With common burnt clay F.P.S. ( non modular ) brick |
| 199 | OD349778/2025-2026:Construction of silt pit 20x20 cm up to 60 cm depth inside dimension with Half brick thick walls in C.M 1:6 all-round over cement concrete 1:2:4using 20 mm broken stone for foundation 10 cm thick plastering with C.M 1:3,12 mm thick two coats etc complete including providing of heavy CI grating 150x150 mm and necessary earthwork excavation etc complete. <br> |
| 200 | 18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 201 | OD349781/2025-2026:Supply and erection of 180mm (6Kg/cm2) or above dia PVC casing (ISI marked) and labour charges of conveyance to site etc. <br> |
| 202 | OD349773/2025-2026:Drilling bore well of suitable size to accommodate weel casing pipe of Dis not less than 180mm for various strata up to 150m below the ground level having an average 40m overburden in all classes of soil and rock inclusive of hire charges for machinery and all other accessories and stores putting up on temporary shed and storing the equipments, cost of fuel, oil and other incidental items to complete the work but excluding the cost of casing pipe etc. complete.<br> |
| 203 | OD349784/2025-2026:Supply and fixing of CPVC puddle pipe with flange minimum 60cm long or as suggested by plumbing contractor which ever is greater in water tank as directed by the engineer in charge 50mm outer diameter |
| 204 | 19.16:Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steeel bar conforming to IS:1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) Complete as per design |
| 205 | OD349777/2025-2026:Supply and providing 1.5 HP bore well single phase motor pump set with all accessories |
| 206 | OD349775/2025-2026:Supply and providing 1.5 HP open well single phase pump set with all accessories |
| 207 | OD349761/2025-2026:Supply, installing, testing and commissioning of control panel for automatic water level controller and alternate working of pumps having level indicator, dry run protection, high volt/low volt cut off, auto/manual operation, stainless steel sensors etc for the automatic on and off function of pump set to control water level in Overhead tank. (For domestic and flushing water transfer pumps) |
| 208 | OD349755/2025-2026:Supply and fixing Woltmann type bulk water meter of 65mm size, removable mechanism type, magnetically coupled, having dry dial, hermetically sealed totaliser, retrofittable for pulse output with pulse wire and remote digital totaliser with RS485 output along with MS panel and capable of withstanding 16bar pressure. (In Rain water pumping main to OHT) |
| 209 | OD349758/2025-2026:Supply, fixing, testing and commissioning of brass body single jet dry type vane wheel cold water meter of 25mm size, antimagnetic type, hermetically sealed totaliser, dry dial, straight reading type with pulse wire output, and remote digital totaliser with RS485 output along with MS panel, and capable of withstanding 16bar pressure. |
| 210 | OD349770/2025-2026:Supplying and fixing of heavy duty slotted rail, full threaded rod, U bolts, universal clamps, nuts and washers for clamping pipes, floor traps etc.in ducts and below ceiling |
| 211 | OD349753/2025-2026:Supplying and fixing 10 mm anchor fastener for fixing threaded rod in position. |
| 212 | OD349757/2025-2026:Supplying and fixing 8mm anchor fastener for fixing threaded rod in position. |
| 213 | APPENDIX C-SEPTIC TANK , SOAK PIT & GARBAGE PIT(Civil work) |
| 214 | 2.9.1:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock |
| 215 | 2.26.2:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock |
| 216 | OD349810/2025-2026:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) using PPC cement with more than25% fly ash etc complete as per GRIHA specifications. |
| 217 | OD349813/2025-2026:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) using PPC cement with 15% fly ash etc complete as per GRIHA specifications. |
| 218 | 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 219 | 5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 220 | 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers |
| 221 | 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 222 | OD349809/2025-2026:Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Additional cement required as per mix design shall be considered by the bidder while quoting. Excess or less cement used as per design mix is not payable or recoverable separately. All work up to plinth level using PPC cement with 15% fly ash etc complete as per GRIHA specification. |
| 223 | OD349812/2025-2026:Extra for providing richer mixes at all floor levels. Note:- Excess cement over the specified cement content used is not payable separately. Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum). |
| 224 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 225 | 19.33:Constructing soak pit 1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. |
| 226 | OD349811/2025-2026:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 ( 1 cement : 6 coarse sand sand) using PPC cement with more than 25% fly ash for foundation and basement including all cost of materials, labour charges etc as per GRIHA specifications. |
| 227 | APPENDIX D-RAIN WATER HARVESTING, FIRE SUMP TANK and STP COLLECTION TANK(Civil work) |
| 228 | 2.9.1:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock |
| 229 | 2.26.2:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock |
| 230 | OD349707/2025-2026:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) using PPC cement with more than25% fly ash etc complete as per GRIHA specifications. |
| 231 | 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 232 | 5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 233 | 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 234 | OD349710/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Additional cement required as per mix design shall be considered by the bidder while quoting. Excess or less cement used as per design mix is not payable or recoverable separately. All work up to plinth level using PPC cement with 15% fly ash etc complete as per GRIHA specification. |
| 235 | OD349708/2025-2026:Extra for providing richer mixes at all floor levels. Note:- Excess cement over the specified cement content used is not payable separately. Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum). |
| 236 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 237 | OD349709/2025-2026:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster using PPC cement with more than 25% fly ash etc complete as per GRIHA specification |
| 238 | 50.18.9.19.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall |
| 239 | 50.18.9.9.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 |
| 240 | 50.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow |
| 241 | 50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend |
| 242 | 50.18.9.22.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee |
| 243 | 50.18.9.22.11:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling |
| 244 | 19.18.1:Supplying and fixing C.I with out frame for manholes:455 x 610 mm rectangular C.I cover ( light duty ) the weight of the cover to be no less than 23 kg |
| 245 | APPENDIX E- COMPOUND WALL & SECURITY CABIN(Civil work) |
| 246 | 2.9.1:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock |
| 247 | 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 248 | 15.9.2:Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar |
| 249 | 5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts |
| 250 | 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers |
| 251 | 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 252 | 5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide |
| 253 | 5.9.19:Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges |
| 254 | OD349795/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Additional cement required as per mix design shall be considered by the bidder while quoting. Excess or less cement used as per design mix is not payable or recoverable separately. All work up to plinth level using PPC cement with 15% fly ash etc complete as per GRIHA specification. |
| 255 | OD349803/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Additional cement required as per mix design shall be considered by the bidder while quoting. Excess or less cement used as per design mix is not payable or recoverable separately. All work above plinth level up to floor V level using PPC cement with 15% fly ash etc complete as per GRIHA specification. |
| 256 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 257 | 5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more |
| 258 | OD349792/2025-2026:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 ( 1 cement : 6 coarse sand sand) using PPC cement with more than 25% fly ash for foundation and basement including all cost of materials, labour charges etc as per GRIHA specifications. |
| 259 | OD349794/2025-2026:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 ( 1 cement : 6 coarse sand sand)using PPC cement with more than 25% fly ash for super structure above plinth level up to floor two level including all cost of materials, labour charges etc as per GRIHA specifications. |
| 260 | OD349789/2025-2026:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand) using PPC cement with more than 25% fly ash etc complete as per GRIHA specification |
| 261 | 9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc |
| 262 | 10.2:Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 263 | 50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 264 | OD349788/2025-2026:Laterate stone tile work for wall lining upto 10 m height with special adhesive over the existing wall surface with specified pattern as per architectural drawings and direction of engineer in charge, in line and levels, including pointing in white cement with an admixture of pigment to match the stone shade including cost and conveyance of material, labour, scaffolding charges etc complete.10 mm thick (polished and machine cut edge) of 30 x 15 cm or nearest size first quality lateratestone tile of red colour and texture |
| 265 | OD349787/2025-2026:Polishing on laterate or granite walls with one or more coats of high gloss stone varnish of approved brand and manufacture as per the direction of engineer-in-charge. |
| 266 | OD349804/2025-2026:Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss/ matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS: 2046 Types S, including cost of adhesive of approved quality.6 mm thick |
| 267 | OD349799/2025-2026:Providing and fixing checkered stainless steel plate including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete with suitable arrangement as per approval of Engineer-in-charge. 2 mm thick checkered stainless steel plate |
| 268 | OD349725/2025-2026:Pad lock 65mm or nearest size (7 lever) best quality <br> |
| 269 | OD349790/2025-2026:Providing and fixing I st quality ceramic glazed wall tiles with atleast 5% recycled content conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) using PPC cement with more than 25% fly ash and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 270 | OD349800/2025-2026:Providing and laying Ceramic glazed floor tiles with atleast 5% recycled content of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) using PPC cement with more than 25% fly ash, including pointing the joints with white cement and matching pigment etc., complete as per GRIHA specification. |
| 271 | OD349791/2025-2026:Providing and laying vitrified floor tiles with atleast 5% recycled content in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand) using PPC cement with more than 25% fly ash, including grouting the joints with white cement and matching pigments etc complete as per GRIHA specification.Size of Tile 600 x 600 mm. |
| 272 | OD349805/2025-2026:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) using PPC cement with more than 25% fly ash etc complete as per GRIHA specification |
| 273 | OD349806/2025-2026:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) using PPC cement with more than 25% fly ash etc complete as per GRIHA specification |
| 274 | OD349807/2025-2026:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster using PPC cement with more than 25% fly ash etc complete as per GRIHA specification |
| 275 | 13.85.3:Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With water thinnable cement primer on walls surface having VOC content less than 50 grams / litre |
| 276 | 13.83.2:Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats |
| 277 | 13.47.1:Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 278 | 13.62.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture . |
| 279 | OD349796/2025-2026:Providing and fixing European type white glazed earthen ware floor mounted one piece water closet of approved make and size including seat cover, cistern with twin flush fittings (6/3L flush) ,nuts, bolts and gasket etc including making connection with the P/S trap, complete in all respect as per directions of Engineer-in-Charge. (Griha Certified product). Snow white One piece EWC of size 660x360x760 mm |
| 280 | OD349801/2025-2026:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass low flow pillar tap (Griha approved) capable of 6lpm @ 3.1 bar head flow rate or nearest flow to the head ratio, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 550x400 mm with 15 mm C.P. brass low flow pillar tap (Griha approved) |
| 281 | OD349802/2025-2026:Supplying and fixing Low flow Health faucet ABS body with wall hook and 1 metre SS braided rubber hose pipe (Griha approved) capable of 6lpm @ 3.1 bar head flow rate or nearest flow to the head ratio. |
| 282 | OD349793/2025-2026:Providing and fixing C.P. brass low flow long body bib cock ( Griha approved) capable of 6lpm @ 3.1 bar head flow rate or nearest flow to the head ratio of approved quality : 15 mm nominal bore |
| 283 | 9.53:Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 284 | 9.72.2:Providing and fixing bright finished brass butt hinges with necessary screws etc. complete:125x70x4 mm ( ordinary type) |
| 285 | 9.97.3:Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm |
| 286 | 9.141:Providing and fixing PVC Door Frame of size 50x47 mm with a wall thickness of 5 mm (±0.2mm), made out of single piece extruded PVC profile, with mitred cut joints and with 2 nos of PVC bracket of size 190 mm x 100 mm long arms of cross section size 35 x 15 mm & self driven self taping screws, the vertical door profiles to be reinforced with 40x20 mm M.S. rectangular tube of 0.8 mm, including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5 mm PVC frame strip with PVC solvent cement on the back of the profile. The door frame to be fixed to the wall using 8x100 mm long anchor fasteners complete, all as per manufacturer's specification and direction of Engineer-in--charge. |
| 287 | 9.142.1:35 mm thick factory made Solid panel PVC Door shutter, made out of singleNon decorative finish (matt finish) |
| 288 | 50.9.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood |
| 289 | 50.9.3.1:Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood |
| 290 | 50.9.4.1:Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood |
| 291 | 9.97.5:Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm |
| 292 | 21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) |
| 293 | 21.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 294 | OD349808/2025-2026:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness meeting GRIHA compliance of overall value VLT>65%, SHGC<0.54,U-Value-3.3W/m2. |
| 295 | 21.11.2:Providing and fixing stainless steel (SS 304 grade) adjustable friction window stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer - in-Charge complete.255 x 19 mm |
| 296 | OD349798/2025-2026:Providing and fixing stainless steel letters of English font of 30cm height including all fittings as per the direction of engineer in charge |
| 297 | APPENDIX F- YARD AND INTERNALROAD(Civil work) |
| 298 | 2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared |
| 299 | 2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock |
| 300 | 16.1:Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. |
| 301 | 16.78.1:Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30 |
| 302 | OD349817/2025-2026:Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid inrequired colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand andcutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern using PPC cement with more than 25% fly ash etc complete as per GRIHA specifications. |
| 303 | OD349819/2025-2026:Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing.1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size) using PPC cement with more than 25% fly ash etc complete as per GRIHA specifications. |
| 304 | OD349818/2025-2026:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) using PPC cement with more than 25% fly ash etc complete as per GRIHA specifications. |
| 305 | 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 306 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 307 | 4.3.2:Centering and shuttering including strutting, propping etc. and removal of form work for:Retaining walls, return walls, (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. |
| 308 | 2.2.1:Earth work in rough excavation, banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with 1/2 tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead up to 50 m and lift up to 1.5 m:All kinds of soil |
| 309 | OD349816/2025-2026:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 ( 1 cement : 6 coarse sand sand) using PPC cement with more than 25% fly ash for foundation and basement including all cost of materials, labour charges etc as per GRIHA specifications. |
| 310 | OD349820/2025-2026:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) using PPC cement with more than 25% fly ash etc complete as per GRIHA specification |
| 311 | 10.25.2:Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 312 | 13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 313 | 30.2.2:Supplying and stacking of good earth at site including royalty and carriage upto 5 k.m. lead complete (earth measured in stacks will be reduced by 20% for payment). |
| 314 | 30.2.3:Supplying and stacking sludge at site including royalty and carriage upto 5 k.m. lead complete (sludge measured in stacks will be reduced by 8% for payment). |
| 315 | 30.2.4.1:Supplying and stacking at site dump manure from approved source, including carriage upto 5 k.m. lead complete (manure measured in stacks will be reduced by 8% for payment) :Screened through sieve of I.S. designation 20 mm |
| 316 | 30.2.7:Fine dressing of the ground |
| 317 | 30.2.8:Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). |
| 318 | 30.2.9:Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge |
| 319 | 30.2.10.1:Grassing with selection No. 1 grass including watering and maintenance of the lawn for 60 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for separately).In rows 5 cm apart in both directions |
| 320 | 30.2.10.2:Grassing with selection No. 1 grass including watering and maintenance of the lawn for 60 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for separately).With grass Turf |
| 321 | 30.2.14.4:Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :Holes 45 cm dia, and 45 cm deep |
| 322 | OD349815/2025-2026:Supplying Shade tress and palm at site for plantation as per direction of engineer in charge. |
| 323 | 30.2.57.1:Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unsaverieable material?s as per direction of officer in charge (excluding cast of plant & water )Cost of plantation per trees plants (for 100 nos.=427.45/100) |
| 324 | 30.2.57.2:Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unsaverieable material?s as per direction of officer in charge (excluding cast of plant & water )Cost of plantation per Shrubs plants (for 200 nos.=427.45/200) |
| 325 | 30.2.57.3:Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unsaverieable material?s as per direction of officer in charge (excluding cast of plant & water )Cost of plantation per Hedge plants (for 300 nos.=427.45/300) |
| 326 | APPENDIX G - SEWAGE TREATMENT PLANT(Civil work) |
| 327 | OD349814/2025-2026:Design, Engineering, Procurement and supplying erection and commissioning of STP capacity 30KLD |
| 328 | Estimate(Electrical work) |
| 329 | OD352453/2025-2026:Supply, installation, testing and commissioning of 11kV Outdoor VCB Panel with HTMetering fabricated in CRCA sheet steel of 2mm thickness with IP - 54 ProtectionEnclosure Powder Coated and then provided with Clear Coating comprising of thefollowing components.1 Nos - 11kV, 630A, 26.3kA for 3 sec Horizontal Draw Out VCB fitted with Manual/ Motor Operated Spring Charging Mechanism with 230V AC Motor and MotorControl Switch, Shunt Trip Coil of 24V DC, Closing Coil of 24V DC, AuxiliaryContact 6NO + 6NC, Mechanical ON/OFF Indicator, Mechanical Operation Counter,Anti Pumping Feature, Automatic Safety Shutters and Push Button3 Nos - 11KV Resin Cast CT (-/5A*, 5P10, 15VA) Dual core1 Nos - 11KV Resin Cast PT (11KV/110V, 100VA, Class 0.5)1 Nos - Instantaneous IDMT Relay with Microprocessor based 3 O/C +1 E/F Relay1 Nos - Master Trip Relay1 Nos - Auxiliary Relay1 Nos - Digital Ammeter1 Nos - Digital Voltmeter1 Set - Indicating Lamps for VCB - ON / OFF, Spring Charge, Trip Circuit Healthy,Breaker Auto TripHT METERING3 Nos - 11KV Resin Cast CT (-/5A*, 10VA, Class 0.2S)1 Nos - 11KV Resin Cast PT (11KV/110V, 25VA, Class 0.2)1 Nos - Provision for fixing HT TOD Meter1 Set - Test Terminal Block with Fuse and Carrier1 Set - Aluminium Bus bar of 630A RatingThere shall be separate chambers for CT, PT units and TOD Meters with KSEBLSealing provision.PANEL ACCESSORIES1 Nos - 6 Window Annunciation Panel with Alarm1 Nos - Power Pack 230V AC-24 V DC1 Nos - Breaker Control Switch1 Nos - Switch with Plug point1 Nos - Space / Strip Heater1 Nos - Thermostat1 Nos - Cubicle lamp with Switchetc. with all other necessary accessories including wiring and connections /interconnections etc. complete as required with bottom entry provision forterminating both incoming and outgoing cables up to and including 3C x 300 Sq.mmHT A2XFY Cable. The panel shall conform to Electrical Inspectorate and KSEBLStandards. The scope also includes the testing of CT, PT units and obtaining testcertificate from TMR KSEBL. (*CT ratio will be furnished later and all Statutory feesshall be remitted by the Client / Consumer or it shall be reimbursed on the submissionof supporting documents) |
| 330 | OD352454/2025-2026:Supply, unloading, installation, testing and commissioning of 160 kVA 11kV/433VIndoor Cast Resin Dry Type Transformer and LBS Panel without HT Meteringhaving the following detailed specifications. The transformer shall have NormalContinuous Rating (kVA) of 160, Voltage Ratio 11kV/433V, No of Phases 3,Frequency 50 Hz, Type of Cooling ANAN, Vector Group Dyn 11, Connections (HV /LV) Delta / Star, Winding Material Copper, Type of Tap changer Off- Circuit TapLinks, Tappings on HV side +5% to -5% in steps of 2.5%, Class of insulation Class F,Lamination Laser Scribed, LV Cable Box with 1 Set of RYB Indication Lamps withControl MCBs, 1 Nos of 250A 36kA 4P Microprocessor Based MCCB Set at 213Ahaving Isolation Duty, 3 O/C + 1 E/F Releases with ROM, Spreader, ON-OFF-TRIPAuxiliary Contact, ON (Red), OFF (Green), TRIP (Amber) Indication Lamps withControl MCBs using copper bus bars of adequate capacity and having sufficient spacewith both bottom and top entry provision for terminating outgoing cable up to andincluding 3.5C x 300 Sq.mm LT A2XFY Cable, Type of Installation Indoor, Fittingsof Lifting lugs, Temperature Indicator, Rating and Diagram Plate, EarthingTerminals, IP 23 Enclosure Powder Coated and then provided with Clear Coating etc.complete as required conforming to IS 2026 and IS 11171.The 11KV LBS Panel without HT Metering shall be with 11KV, 630A, 26.3KA, 3Phase, 50 Hz, Air Break, Manual Front operated LBS having Load Breaking andFault Making Duty with Operating Handle, 3 Nos of HRC Fuse Units, Mechanicaland Electrical Trip Push Button, 230V AC Trip Coil Voltage, ON-OFF Indicator withFuses / MCBs, Aluminium Busbars of 630A Rating, Support Insulators, Earth Switch,Interlocking facility between SFU and Earth Switch, Space Heater and Thermostatconforming to IS 9920 with all other necessary accessories including wiring andconnections / interconnections etc. complete as required with HV cable box havingsufficient space with both bottom and top entry provision for terminating incomingcable up to and including 3C x 300 Sq.mm HT A2XFY Cable. The Transformer andLBS shall conform to Electrical Inspectorate and KSEBL Standards |
| 331 | OD352455/2025-2026:Supply, unloading, installation, testing and commissioning of 125 kVA DieselGenerator Set with Acoustic Enclosure conforming to CPCB IV norms. The DG Setshall have the specifications as follows:-ENGINEDiesel Oil Engine with direct injection, 4 stroke vertical in line cylinders, liquidcooled with specified shaft output after reduction of power for engine Auxiliaries andwhen operating at a governed speed of 1500 RPM at NTP condition. The engine shallbe suitable for continuous duty and conform to IS 10000 or other necessary standardsas required. The engine shall be with all standard specifications, accessories, fittingsetc. complete as requiredALTERNATORSelf-excited, self-regulated, screen protected, drip proof alternator with staticexcitation system, capable of developing rated output at 415 V, Power Factor 0.8,Frequency 50 Hz when running at 1500 RPM at NTP conditions and conforming toIS 4722 etc. complete as requiredCONTROL PANELFloor mounting sheet steel construction fabricated out of 1.6mm sheets and with one /two hinged front doors of 2 mm sheet steel bolted back / sides, totally enclosed and vermin proof with the following components.1 Nos - Digital Multifunction Meter measuring Alternator parameters like Voltage,Frequency, Amps, KW, KVAR, PF etc.3 Nos - 200/5A 5VA CL:1 CT1 Nos - Three Phase 4 Wire KWH Meter1 Set - Aluminium Busbars of 200A Rating2 Nos - Indicating lamps showing SET RUNNING and SET ON LOAD1 Nos - 200A 36kA 4P MCCB with Shunt Release3 Nos - Instrument Fuses2 Nos - Earthing Studs1 Nos - Earth Fault Relay1 Nos - 40/5A 5VA or Required CL: 5P10 Neutral CTetc. complete as required.ACOUSTIC ENCLOSUREFabricated out of 16 SWG CRCA MS sheet with nut bolt type construction, Powdercoating done after seven-tank surface preparation process of sheet metal, Canopypanel and doors shall have inside lining of Fire Retardant foam as acoustic material,four hinged doors shall be provided to canopy, one door shall have glass window forcontrol panel etc. complete as requiredNOISE LEVEL75 DB at 1 metre from the enclosure surface under free field conditions as per CPCBNorms etc. complete as requiredBASE FRAMEFabricated in sheet metal, rugged in construction, designed for mounting engine andclose coupled, with cross members mounted on AVM, having provision for mountingof acoustic enclosure, lifting hook for convenient lifting of complete set, i.e., alongwith canopy, engine and alternator etc. complete as requiredFUEL TANKRemovable type fuel tank with 8 hours full load running capacity fabricated out ofCRCA MS sheet duly painted and fitted with inlet and outlet connections etc.complete as requiredACCESSORIES1 Nos - Dry 12V Battery1 Nos - Battery Charger1 Set - Battery leads1 Nos - Exhaust Expansion Bellowetc. complete as requiredREMOTE MONITORING SYSTEMDG Set shall be linked with a central monitoring data server through SIM and internetin order to view all critical indicators on mobile or laptop with alarms etc. completeas requiredThe scope also includes the testing of Energy Meter, CTs, Relays etc. and obtainingtest certificate from Electrical Inspectorate. (*All Statutory fees shall be remitted bythe Client / Consumer or it shall be reimbursed on the submission of supportingdocuments) |
| 332 | OD353433/2025-2026:Supply, installation, testing and commissioning of Floor Mounting Cubical Type Main Switch Board Panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having sufficient front surface area fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame works and covers, 3 mm for gland plates, cleaning and finishing complete with 7 tank process for powder coating in approved shade and then provided with clear coating, having 250 Amps capacity TPN Aluminium alloy busbars of high conductivity, DMC / SMC / FRP busbar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 6 mm at the rear with 2 Nos. earth stud, solid connections from main busbars to switch gears with approved size of Aluminium busbars and control wiring with 2.5 / 1.5 Sq.mm FRLS (Flame Retardant Low Smoke) or HRFR (Heat Resistant Flame Retardant) PVC insulated single core copper conductor cables, cable alleys etc. complete as required. For all MCCBs Ics shall be 100% Icu. The panel shall conform to the Electrical Inspectorate standards and it shall only be manufactured after getting approval from the Engineer-in-charge, Consultant and the Electrical Inspectorate |
| 333 | OD352456/2025-2026:Supply, installation, testing and commissioning of Floor Mounting Cubical Type Automatic Power Factor Correction Panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having sufficient front surface area fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame works, covers and gland plates, cleaning and finishing complete with 7 tank process for powder coating in approved shade and then provided with clear coating, having 125 Amps capacity TPN Aluminium alloy bus bars of high conductivity, DMC / SMC / FRP bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 3 mm at the rear with 2 Nos. earth stud, solid connections from main bus bars to switch gears with approved size of Aluminium bus bars and control wiring with 2.5 / 1.5 Sq.mm FRLS (Flame Retardant Low Smoke) or HRFR (Heat Resistant Flame Retardant) PVC insulated single core copper conductor cables, cable alleys etc. complete as required. For all MCCBs Ics shall be 100% Icu. The panel shall conform to the Electrical Inspectorate standards and it shall only be manufactured after getting approval from Engineer-in-charge, Consultant and the Electrical InspectorateBUSBAR1 Runs of 20 mm x 10 mm Aluminium for each Phase1 Runs of 20 mm x 6 mm Aluminium for NeutralINCOMER1 Set - RYB Indication Lamps with Control MCBs1 Nos - 125A 25kA 4P Thermal Magnetic Type MCCB having 70 to 100% SettingProvision with ROM, Spreader, ON-OFF-TRIP Auxiliary Contact and ON (Red),OFF (Green), TRIP (Amber) Indication Lamps with Control MCBs3 Nos - 125/5A 10VA CL:1 Resin Cast CT1 Nos - Digital Multifunction Meter measuring V, A, F, KWH, KVA, PF withControl MCBs1 Nos - 8 Stage Digital Microprocessor Based APFC Relay with Control MCBs2 Nos - Control Contactor with 4 NO + 4 NC Contacts1 Nos - Auto - Manual Selector Switch (2 Pole 2 Way)1 Nos - 250/5A 10VA CL:1 Resin Cast CT in EB Side of MSBSURGE PROTECTION DEVICE1 Nos - 4 Module DIN Rail Mounting Type 1 + Type 2 100kA SPD on the incomingside of Switch Disconnector along with Green and Red Indication Lamps withControl MCBs including wiring and connections etc. complete as required. (Theconnections to RYB Phases, Neutral and Earth shall be done using 16 Sq.mm SingleCore Flexible Copper cables with less than 0.45m in length)OUTGOINGS2 Nos - 32A D Curve TP MCB with Capacitor Duty Contactor, ON (Red), OFF(Green) Push Buttons, ON (Red), OFF (Green) Indication Lamps with Control MCBsand 15 KVAr Heavy Duty Cylindrical Type Capacitor2 Nos - 20A D Curve TP MCB with Capacitor Duty Contactor, ON (Red), OFF(Green) Push Buttons, ON (Red), OFF (Green) Indication Lamps with Control MCBsand 10 KVAr Heavy Duty Cylindrical Type Capacitor1 Nos - 20A D Curve TP MCB with Capacitor Duty Contactor, ON (Red), OFF(Green) Push Buttons, ON (Red), OFF (Green) Indication Lamps with Control MCBsfor connecting 10 KVAr Heavy Duty Cylindrical Type Capacitor in future2 Nos - 10A D Curve TP MCB with Capacitor Duty Contactor, ON (Red), OFF(Green) Push Buttons, ON (Red), OFF (Green) Indication Lamps with Control MCBsand 5 KVAr Heavy Duty Cylindrical Type Capacitor1 Nos - 10A D Curve TP MCB with Capacitor Duty Contactor, ON (Red), OFF(Green) Push Buttons, ON (Red), OFF (Green) Indication Lamps with Control MCBsfor connecting 5 KVAr Heavy Duty Cylindrical Type Capacitor in future1 Nos - 10A D Curve TP MCB with 5 KVAr Heavy Duty Cylindrical Type Capacitor2 Nos - Air Vent (8 Inches)2 Nos - Cooling Fan (8 Inches) |
| 334 | OD352457/2025-2026:Supply, installation, testing and commissioning of Floor Mounting Cubical Type Common Switch Board Panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having sufficient front surface area fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame works, covers and gland plates, cleaning and finishing complete with 7 tank process for powder coating in approved shade and then provided with clear coating, having 125 Amps capacity TPN Aluminium alloy bus bars of high conductivity, DMC / SMC / FRP bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 3 mm at the rear with 2 Nos. earth stud, solid connections from main bus bars to switch gears with approved size of Aluminium bus bars and control wiring with 2.5 / 1.5 Sq.mm FRLS (Flame Retardant Low Smoke) or HRFR (Heat Resistant Flame Retardant) PVC insulated single core copper conductor cables, cable alleys etc. complete as required. For all MCCBs Ics shall be 100% Icu. The panel shall conform to the Electrical Inspectorate standards and it shall only be manufactured after getting approval from the Engineer-in-charge, Consultant and the Electrical InspectorateBUSBAR1 Runs of 20 mm x 10 mm Aluminium for each Phase1 Runs of 20 mm x 6 mm Aluminium for NeutralMETERING4 Nos - Provision for fixing Resin Cast CTs1 Nos - Provision for fixing CT Operated Three Phase Energy MeterThere shall be KSEBL Sealing Provision for CT Compartment and Energy MeterINCOMER1 Set - RYB Indication Lamps with Control MCBs1 Nos - 125A 25kA 4P Thermal Magnetic Type MCCB having 70 to 100% SettingProvision with ROM, Spreader, Shunt Release, ON-OFF-TRIP Auxiliary Contact andON (Red), OFF (Green), TRIP (Amber) Indication Lamps with Control MCBs3 Nos - 125/5A 10VA CL:1 Resin Cast CT1 Nos - Digital Multifunction Meter measuring V, A, F, KWH, KVA, PF withControl MCBs1 Nos - Earth Leakage Relay with CBCT and Control MCBsSURGE PROTECTION DEVICE1 Nos - 4 Module DIN Rail Mounting Type 1 + Type 2 100kA SPD on the incomingside of Incomer MCCB along with Green and Red Indication Lamps with ControlMCBs including wiring and connections etc. complete as required. (The connectionsto RYB Phases, Neutral and Earth shall be done using 16 Sq.mm Single Core FlexibleCopper cables with less than 0.45m in length)OUTGOINGS2 Nos - 80A 25kA 4P Thermal Magnetic Type MCCB having 70 to 100% SettingProvision with ROM, Spreader, ON-OFF-TRIP Auxiliary Contact and ON (Red),OFF (Green), TRIP (Amber) Indication Lamps with Control MCBs3 Nos - 63A 25kA 4P Thermal Magnetic Type MCCB having 70 to 100% SettingProvision with ROM, Spreader, ON-OFF-TRIP Auxiliary Contact and ON (Red),OFF (Green), TRIP (Amber) Indication Lamps with Control MCBs1 Nos - 40A 25kA 4P Thermal Magnetic Type MCCB having 70 to 100% SettingProvision with ROM, Spreader, ON-OFF-TRIP Auxiliary Contact and ON (Red),OFF (Green), TRIP (Amber) Indication Lamps with Control MCBs2 Nos - Outdoor / Street Light Cubicle with 25A C Curve 4P MCB, 25A 30mA 4PRCCB, 25A 4P AC3 Duty Contactor, 24Hour Digital Timer Switch, Auto - ManualSelector Switch (2 Pole 2 Way), ON (Red) and OFF (Green) Push Buttons, ON (Red),OFF (Red) Indication lamps with Control MCBs |
| 335 | OD352458/2025-2026:Supply, installation, testing and commissioning of Floor Mounting Cubical Type Switch Board Panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having sufficient front surface area fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame works, covers and gland plates, cleaning and finishing complete with 7 tank process for powder coating in approved shade and then provided with clear coating, having 125 Amps capacity TPN Aluminium alloy busbars of high conductivity, DMC / SMC / FRP busbar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 3 mm at the rear with 2 Nos. earth stud, solid connections from main busbar to switch gears with approved size of Aluminium busbars and control wiring with 2.5 / 1.5 Sq.mm FRLS (Flame Retardant Low Smoke) or HRFR (Heat Resistant Flame Retardant) PVC insulated single core copper conductor cables, cable alleys etc. complete as required. For all MCCBs Ics shall be 100% Icu. The panel shall conform to the Electrical Inspectorate standards and it shall only be manufactured after getting approval from the Engineer-in-charge, Consultant and the Electrical InspectorateBUSBAR1 Runs of 20 mm x 10 mm Aluminium for each Phase1 Runs of 20 mm x 6 mm Aluminium for NeutralINCOMER1 Set - RYB Indication Lamps with Control MCBs1 Nos - 125A 25kA 4P Thermal Magnetic Type MCCB having 70 to 100% SettingProvision with ROM, Spreader, Shunt Release, ON-OFF-TRIP Auxiliary Contact andON (Red), OFF (Green), TRIP (Amber) Indication Lamps with Control MCBs3 Nos - 125/5A 10VA CL:1 Resin Cast CT1 Nos - Digital Multifunction Meter measuring V, A, F, KWH, KVA, PF withControl MCBs1 Nos - Earth Leakage Relay with CBCT and Control MCBsSURGE PROTECTION DEVICE1 Nos - 4 Module DIN Rail Mounting Type 1 + Type 2 100kA SPD on the incomingside of Incomer MCCB along with Green and Red Indication Lamps with ControlMCBs including wiring and connections etc. complete as required. (The connectionsto RYB Phases, Neutral and Earth shall be done using 16 Sq.mm Single Core FlexibleCopper cables with less than 0.45m in length)OUTGOINGS1 Nos - 80A 25kA 4P Thermal Magnetic Type MCCB having 70 to 100% SettingProvision with ROM, Spreader, ON-OFF-TRIP Auxiliary Contact and ON (Red),OFF (Green), TRIP (Amber) Indication Lamps with Control MCBs3 Nos - 63A 25kA 4P Thermal Magnetic Type MCCB having 70 to 100% SettingProvision with ROM, Spreader, ON-OFF-TRIP Auxiliary Contact and ON (Red),OFF (Green), TRIP (Amber) Indication Lamps with Control MCBs2 Nos - 40A 25kA 4P Thermal Magnetic Type MCCB having 70 to 100% SettingProvision with ROM, Spreader, ON-OFF-TRIP Auxiliary Contact and ON (Red),OFF (Green), TRIP (Amber) Indication Lamps with Control MCBs |
| 336 | OD352459/2025-2026:Supply, installation, testing and commissioning of Wall Mounting Cubical Type LiftPanel Board suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system havingsufficient front surface area fabricated in compartmentalized design from CRCAsheet steel of 2 mm thick for frame works, covers and gland plates, cleaning andfinishing complete with 7 tank process for powder coating in approved shade and thenprovided with clear coating, having 63 Amps capacity type TPN Aluminium alloy busbars of high conductivity, DMC / SMC / FRP bus bar supports, with short circuitwithstand capacity of 31 MVA for 1 Sec., fabrication shall be done in transportablesections, entire panel shall have a common copper earth bar of size 20 mm x 3 mm atthe rear with 2 Nos. earth stud, solid connections from main bus bar to switch gearswith required size of Aluminium bus bars and control wiring with 2.5 / 1.5 Sq.mmFRLS (Flame Retardant Low Smoke) or HRFR (Heat Resistant Flame Retardant)PVC insulated single core copper conductor cables, cable alleys etc. complete asrequired. For all MCCBs Ics shall be 100% Icu. The panel shall conform to theElectrical Inspectorate standards and it shall only be manufactured after gettingapproval from the Engineer-in-charge, Consultant and the Electrical InspectorateBUSBAR1 Runs of 20 x 6mm Aluminium for each Phase1 Runs of 20 x 6mm Aluminium for NeutralINCOMER1 Set - RYB Indication lamps with Control MCBs1 Nos - 63A 4P Switch DisconnectorOUTGOING 11 Nos - 40A C Curve 4P MCB1 Nos - 40A 100mA 4P RCCBOUTGOING 21 Nos - 25A C Curve DP MCB1 Nos - 25A 30mA DP RCCB2 Nos - 16A C Curve SP MCB2 Nos - 6A C Curve SP MCBOUTGOING 31 Nos - 25A C Curve DP MCB1 Nos - 25A 30mA DP RCCB2 Nos - 16A C Curve SP MCB2 Nos - 6A C Curve SP MCB |
| 337 | OD352460/2025-2026:Supply, installation, testing and commissioning of Wall Mounting Cubical TypeChangeover Enclosure suitable for 415V, Three Phase, 4 Wire 50Hz AC supplysystem having sufficient front surface area fabricated in compartmentalized designfrom CRCA sheet steel of 2 mm thick for frame work, covers and gland plates,cleaning and finishing complete with 7 tank process for powder coating in approvedshade and then provided with clear coating and control wiring with 2.5 / 1.5 Sq. mm.PVC insulated FRLS (Flame Retardant Low Smoke) or HRFR (Heat Resistant FlameRetardant) copper conductor cables, cable alleys etc. complete as required. Theenclosure shall conform to the Electrical Inspectorate standards and it shall only bemanufactured after getting approval from the Engineer-in-charge, Consultant and theElectrical Inspectorate.COMPONENTS2 Set - RYB Indication Lamps with Control MCBs1 Nos - 63A 4P On Load Changeover Switch |
| 338 | OD352461/2025-2026:Supply and installation of Neutral CT Enclosure with front door for mounting existing duly tested Resin Cast CT having sufficient front surface area fabricated in compartmentalized design from CRCA sheet steel of 2mm thick for frame work and door, cleaning and finishing complete with 7 tank process for powder coating in approved shade and then provided with clear coating, having openings in both top and bottom for fixing copper bar of required size, fixed on already fabricated and painted MS structural supports etc. complete as required |
| 339 | OD352462/2025-2026:Supply and installation of Neutral CT with NABL Certification or after getting it duly tested from Electrical Inspectorate in the existing powder coated enclosure box. The CT shall have sufficient ID for fixing primary copper bar of required size through the existing powder coated enclosure box with necessary wiring and connections etc. complete as required. (*All Statutory / Testing fees shall be remitted by the Client / Consumer or it shall be reimbursed on the submission of supporting documents) Up to and including 50/5A 5VA CL:5P10 Resin Cast CT |
| 340 | OD353435/2025-2026:Supply, installation, testing and commissioning of Red Mushroom Head Emergency Stop Switch Push Button with Enclosure etc. complete as required |
| 341 | 90.11.1.19:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 342 | 90.14.10.4:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL |
| 343 | 90.11.1.11:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43) |
| 344 | 90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 345 | 90.11.1.15:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 346 | 2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door |
| 347 | 2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door |
| 348 | OD353436/2025-2026:Supplying and fixing FP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts "C" curve FP MCB complete with connections, testing and commissioning etc. as required. |
| 349 | OD353437/2025-2026:Supply and installation of IP 65 Thermoplastic Polycarbonate 4 Way DB of the following size suitable for unprotected outdoor application having provision for fixing 4 Pole Isolator / MCB. The DB shall have multi-level and pre-moulded knockouts on both bottom and top for glanding up to and including 16 Sq.mm A2XFY cables from both sides. The DB shall also come with protective cover and it shall fulfil the standards of IEC 60670-24, IEC 60695-2-11 : Flame Retardant and Self-Extinguishing, Glow Wire tested at minimum 960 Deg.C, IEC 60529 : IP 65 Degree of Protection and Resistance to Impact : IK 08 (5 Joule) etc. complete as required. 126 x 228 x 111mm (Width x Height x Depth) |
| 350 | OD353438/2025-2026:Supply and installation of IP 65 Thermoplastic Polycarbonate Enclosure of the following size with hinged door having multi-level knockouts for glanding cables of different sizes and the provision for fixing wiring terminals. The enclosure shall fulfil the standards of IEC 60529-2, Environment Friendly, Recyclable, Chemical Resistant, UV Resistant, Double Insulated, Shock Proof, Glow Wire Tested 960 Deg.C, Fire Retardant, Self Extinguishing etc. complete as required 300 x 300 x 170mm (Width x Height x Depth) |
| 351 | OD353440/2025-2026:Supply and installation of Ring type terminals suitable to terminate both incoming and outgoing 3.5 Core Aluminium/Copper cables up to and including 50 Sq.mm along with 2 Nos of both incoming and outgoing 25 Sq.mm/6SWG earth terminals including end plates and end clamp in DIN Rail in the existing IP 65 Thermoplastic Polycarbonate Enclosure etc. complete as required |
| 352 | OD353441/2025-2026:Supply and installation of Ring type terminals suitable to terminate both incoming and outgoing 3.5 Core Aluminium/Copper cables up to and including 35 Sq.mm along with 2 Nos of both incoming and outgoing 25 Sq.mm/6SWG earth terminals including end plates and end clamp in DIN Rail in the existing IP 65 Thermoplastic Polycarbonate Enclosure etc. complete as required |
| 353 | OD353442/2025-2026:Supply and installation of Ring type terminals suitable to terminate both incoming and outgoing 4 Core Aluminium/Copper cables up to and including 25 Sq.mm along with 2 Nos of both incoming and outgoing 16 Sq.mm/8SWG earth terminals including end plates and end clamp in DIN Rail in the existing IP 65 Thermoplastic Polycarbonate Enclosure etc. complete as required |
| 354 | OD353443/2025-2026:Supply and installation of IP 67 Thermoplastic Polycarbonate PC - GFS Junction Box for unprotected outdoor application with multi-level knockouts for glanding cables of different sizes with internally embedded gasket technology (Polyurethane). The lid fasteners shall have captive type thermoplastic screws with quarter turn knob option and the junction box shall fulfill the standards of IEC 60670-22 : Particular requirements for connecting boxes and enclosures, IEC 60695-2-11 : Glow Wire tested at minimum 960 Deg.C, Impact Resistant : IK 09 (10 Joule), Halogen Free as per IEC 60 754-2 with 4 Pole loop in and loop out terminals suitable to terminate up to and including 16 Sq.mm A2XFY cables and also having provision for fixing DP Isolator / MCB etc. complete as required |
| 355 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 356 | 2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 357 | 2.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.25 amps |
| 358 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 359 | 2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.63 amps |
| 360 | OD353445/2025-2026:Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Four pole |
| 361 | OD353446/2025-2026:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Four pole |
| 362 | OD353447/2025-2026:Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole |
| 363 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 364 | 2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole |
| 365 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 366 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 367 | OD353448/2025-2026:Supply, installation, testing and commissioning of Three Phase DOL Submersible Pump Controller / Starter Panel having Rated Voltage 415V, Frequency 50Hz with Phase Failure Relay, Ampere Voltage Meter, Contactor, Thermal Overload Relay etc. complete as required Up to and including 5HP |
| 368 | OD353452/2025-2026:Supply and laying of 11kV grade XLPE insulated armoured HT cable of the following sizes and laying in the existing earth excavated trenches, built up trenches, clamping in built up trenches / trays using heavy duty Aluminium / GI / SS Flat or by using heavy duty GI / SS Saddles of which spacing between 30cm to 60cm and pulling through pipes including all minor civil works etc. complete as required.3C x 300 Sq.mm |
| 369 | 10.4.4:Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm |
| 370 | 10.5.4:Supplying and making outdoor cable end termination with heat shrinkable jointing kit completewith all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductorcable of 11 KV grade as required :300 sq. mm |
| 371 | OD353485/2025-2026:Supply and laying of XLPE insulated and PVC sheathed armoured aluminium power cable of 1.1 kV grade of the following sizes in the existing earth excavated trenches, built up trenches, and pulling through pipes etc. complete as required. 3.5 core 185 Sq.mm |
| 372 | OD353486/2025-2026:Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 150 sq mm |
| 373 | OD353487/2025-2026:Supply and laying of XLPE insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing earth excavated trenches, built up trenches, and pulling through pipes etc. complete as required. 4 core 25 Sq.mm |
| 374 | OD353488/2025-2026:Supply and laying of XLPE insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing earth excavated trenches, built up trenches, and pulling through pipes etc. complete as required. 4 core 10 Sq.mm |
| 375 | OD353489/2025-2026:Supply and laying of XLPE insulated and PVC sheathed armoured copper power cable of 1.1 KV grade of the following sizes in the existing earth excavated trenches, built up trenches, and pulling through pipes etc. complete as required. 4 core 2.5 Sq.mm |
| 376 | OD353459/2025-2026:Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 4 sq mmSupply and laying of XLPE insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing earth excavated trenches, built up trenches, and pulling through pipes etc. complete as required. 2 core 2.5 Sq.mm |
| 377 | 90.12.7.28:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp |
| 378 | 90.12.7.29:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp |
| 379 | 90.12.7.30:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm |
| 380 | 90.12.7.31:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 95 sq mm |
| 381 | 90.12.7.33:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 150 sq mm |
| 382 | 90.12.7.34:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm |
| 383 | 90.12.7.39:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp |
| 384 | 90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp |
| 385 | 90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp |
| 386 | 90.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp |
| 387 | OD356704/2025-2026:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages, colour washing etc. as required.2 core 2.5 sq mm with factory made clamp |
| 388 | OD356705/2025-2026:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 2.5 sq mm with factory made clamp |
| 389 | 9.1.21:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) |
| 390 | 9.1.22:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm) |
| 391 | 9.1.23:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm) |
| 392 | 9.1.24:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm) |
| 393 | 9.1.26:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm) |
| 394 | 9.1.27:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm) |
| 395 | 9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 396 | 9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) |
| 397 | 9.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm) |
| 398 | OD356790/2025-2026:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 2.5 sq. mm |
| 399 | OD356791/2025-2026:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 6 sq. mm |
| 400 | OD356808/2025-2026:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 2.5 sq. mm |
| 401 | OD356796/2025-2026:Supply and providing gland earthing using Gland Earthing Clips / Clamps / Copper Strip for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 2.5 Sq. mm |
| 402 | OD356797/2025-2026:Supply and providing gland earthing using Gland Earthing Clips / Clamps / Copper Strip for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 2.5 Sq. mm |
| 403 | OD356798/2025-2026:Supply and providing gland earthing using Gland Earthing Clips / Clamps / Copper Strip for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 6 Sq. mm |
| 404 | OD356799/2025-2026:Supply and providing gland earthing using Gland Earthing Clips / Clamps / Copper Strip for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 Sq. mm |
| 405 | OD356800/2025-2026:Supply and providing gland earthing using Gland Earthing Clips / Clamps / Copper Strip for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 Sq. mm |
| 406 | OD356801/2025-2026:Supply and providing gland earthing using Gland Earthing Clips / Clamps / Copper Strip for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 25 Sq. mm |
| 407 | OD356802/2025-2026:Supply and providing gland earthing using Gland Earthing Clips / Clamps / Copper Strip for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2 X 35 Sq. mm |
| 408 | OD356803/2025-2026:Supply and providing gland earthing using Gland Earthing Clips / Clamps / Copper Strip for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2 X 50 Sq. mm |
| 409 | OD356804/2025-2026:Supply and providing gland earthing using Gland Earthing Clips / Clamps / Copper Strip for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2 X 70 Sq. mm |
| 410 | OD356805/2025-2026:Supply and providing gland earthing using Gland Earthing Clips / Clamps / Copper Strip for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2 X 95 Sq. mm |
| 411 | OD356806/2025-2026:Supply and providing gland earthing using Gland Earthing Clips / Clamps / Copper Strip for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2 X 150 Sq. mm |
| 412 | OD356807/2025-2026:Supply and providing gland earthing using Gland Earthing Clips / Clamps / Copper Strip for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2 X 185 Sq. mm |
| 413 | OD356858/2025-2026:Excavation of all types of soils for the laying of PVC insulated and PVC sheathed / XLPE Aluminium or Copper conductor cable, GI / DWC HDPE / RCC / PVC / Conduit Pipes, Earthing conductors to the required width and depth up to and including 1.2m and back fillingetc. complete as required. (The trench dimensions and specifications shall conform to CPWD / PWD, Electrical Inspectorate and KSEBL Standards) |
| 414 | OD356812/2025-2026:Supply and providing sand cushioning by laying it above the PVC insulated and PVC sheathed / XLPE Aluminium or Copper conductor cable, GI / DWC HDPE / RCC / PVC / Conduit Pipes, Earthing conductors in the existing excavated trench etc. complete as required |
| 415 | OD356813/2025-2026:Supply and providing protective covering by laying bricks breadth wise above the PVC insulated and PVC sheathed / XLPE Aluminium or Copper conductor cable, GI / DWC HDPE / RCC / PVC / Conduit Pipes, Earthing conductors in the existing excavated trench etc. completeas required |
| 416 | OD356814/2025-2026:Supply and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted / welded to 35 mm X 35 mm X 6 mm GI angle iron, 60 cm long painted with 2 coats of epoxy primer and 2 coats of epoxy paint and fixing the same in ground with cement concrete in M.15 Grade (1:2:4) etc. complete as required |
| 417 | 90.12.24.2:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.4 sq mm |
| 418 | 90.12.24.3:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.6 Sq mm |
| 419 | 90.12.24.4:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm |
| 420 | 90.12.24.5:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.16 sq mm |
| 421 | 90.12.24.6:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.25 sq mm |
| 422 | 90.12.24.7:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.35 sq mm |
| 423 | 90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size |
| 424 | OD356824/2025-2026:Earthing with C.I. earth plate 1200 mm X 1200 mm X 12.6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 425 | OD356822/2025-2026:Earthing with C.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 426 | OD356823/2025-2026:Earthing with ISI Marked Nickel Sealed Copper Bonded 20mm dia, 3.0m long Rod having 250 microns coating thickness with T clamp including Stainless Steel Nuts, Bolts, Round Washers, Spring Washers and other required accessories and providing masonry enclosure with cover plate having locking arrangement with sufficient earthing compound etc. complete as required |
| 427 | OD356817/2025-2026:Supply of Stainless Steel 304 Grade 6mm x 11/4 Inch bolts and its nuts, spring washers and double round washers etc. complete as required |
| 428 | OD356818/2025-2026:Supply of Stainless Steel 304 Grade 6mm x 1 Inch bolts and its nuts, spring washers and double round washers etc. complete as required |
| 429 | OD356819/2025-2026:Supply and laying of the earthing conductors of the following size and laying in earth excavated trenches, built up trenches, clamping in trays, walls, racks, risers, trusses etc. using heavy duty Aluminium / GI flats or existing DMC / Epoxy supports of which spacing between 35cm to 65cm without making holes in the earthing conductor and pulling through pipes including all minor civil works, including connection / terminating with existing Stainless Steel bolts, nuts, round and spring washers after tinning process etc. complete as required. (Jointing shall be done by overlapping and with existing 2 sets of Stainless Steel bolts, nuts, round and spring washersspaced at 50mm) 25mm x 3mm Copper Strip |
| 430 | OD356820/2025-2026:Supply and laying of the earthing conductors of the following size and laying in earth excavated trenches, built up trenches, clamping in trays, walls, racks, risers, trusses etc. using heavy duty Aluminium / GI flats or existing DMC / Epoxy supports of which spacing between 35cm to 65cm without making holes in the earthing conductor and pulling through pipes including all minor civil works, including connection / terminating with existing Stainless Steel bolts, bolts, round and spring washers after tinning process etc. complete as required. (Jointing shall be done by overlapping and with existing 2 sets of Stainless Steel bolts, nuts, round and spring washersspaced at 50mm). 20mm x 3mm Copper Strip |
| 431 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 432 | 90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) |
| 433 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 434 | 90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) |
| 435 | OD357026/2025-2026:Supply and installation of 10 kg/cm2 PVC Pipes of the following sizes with all necessary accessories and laying in existing earth excavated trenches, built up trenches, clamping in built up trenches / walls using Stainless Steel saddles and screws of which spacing between 30cm to 60cm including all minor civil works etc. complete as requiredUp to and including 40mm |
| 436 | OD357027/2025-2026:Supply and installation of Tinned Stainless Steel Earth Bench / Terminal Strip of 8 Poles manufactured in accordance with IS / IEC 62305-3:2010 and IEC 62561-2:2012 with Stainless Steel bolts, nuts, round and spring washers or screws etc. The Terminal Strip shall have thespecifications of minimum Width 25mm, Thickness 4mm, insulations provided at mounting ends etc. complete as required |
| 437 | OD357028/2025-2026:SuppIy and installtion of ISI Marked Nickel Sealed Copper Bonded 16mm dia, 2m long Vertical Air Termination Rod with Tinned Spike and Nylon Insulated Base manufactured in accordance with latest International, Indian Standards and Regulations |
| 438 | OD357029/2025-2026:SuppIy and installtion of ISI Marked Nickel Sealed Copper Bonded 16mm dia, 1m long Vertical Air Termination Rod with Tinned Spike and Nylon Insulated Base manufactured in accordance with latest International, Indian Standards and Regulations |
| 439 | OD357030/2025-2026:Supply and installation of DMC / Epoxy Insulator for fixing 20mm x 3mm Copper Strip Lightning Conductor on parapet, roofs, walls etc. using necessary Stainless Steel bolts, nuts, round and spring washers or screws etc. complete as required |
| 440 | OD358291/2025-2026:Supply and laying of 50.0 Sq.mm single core flexible Aluminium conductor cable designed to withstand the demanding environmental conditions that arise in any fixed, mobile, roof or architecturally integrated Photovoltaic Lightning Protection System through the existing conduit with all necessary accessories. The cable shall have the specifications of Base Material Aluminium in accordance with IS / IEC 62305- 3:2010, Diameter of each strand 8mm, Insulation Material PVC Compound with UV Resistant, Nominal Insulation Thickness 2mm, DC Conductor Resistance at 20 Deg.C 0.641 Ohms/Km, Insulation Resistance Constant at 20 Deg.C (Min) 36.70 M.Ohm/Km, HV Test Core to Water 10kV for 5 minutes etc. complete as required |
| 441 | OD357032/2025-2026:Supply of superior quality Aluminium palm socket for 50.0 Sq.mm single core flexible Aluminium conductor cable including crimping, giving connections to the required conductor or surface using existing Stainless Steel bolts, nuts, round and spring washer etc. complete as required |
| 442 | OD357033/2025-2026:Supply and installtion of SMC Junction Box at a height of 1.5m from ground level and providing test link for the lightning conductor with necessary supports and Stainless Steel bolts, buts, round and spring washers or screws conforming to IS / IEC 62305-3:2010 and ElectricalInspectorate Standards etc. complete as required |
| 443 | 4.1.1:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness |
| 444 | 4.1.2:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 445 | 4.1.3:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness |
| 446 | 4.1.5:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.375 mm width X 50 mm depth X 2.0 mm thickness |
| 447 | 4.2.1:Supplying and installing following size of perforated pre-painted M.S. cable trays bends withperforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness |
| 448 | 4.2.2:Supplying and installing following size of perforated pre-painted M.S. cable trays bends withperforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 449 | 4.2.3:Supplying and installing following size of perforated pre-painted M.S. cable trays bends withperforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness |
| 450 | 4.2.5:Supplying and installing following size of perforated pre-painted M.S. cable trays bends withperforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.375 mm width X 50 mm depth X 2.0 mm thickness |
| 451 | 4.3.1:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness |
| 452 | 4.3.2:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 453 | 4.3.3:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.225mm width X 50 mm depth X 1.6 mm thickness |
| 454 | 4.3.5:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.375 mm width X 50 mm depth X 2.0 mm thickness |
| 455 | 4.4.1:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts &nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness |
| 456 | 4.4.3:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts &nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness |
| 457 | 4.4.5:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts &nuts, painting suspenders etc as required.375 mm width X 50 mm depth X 2.0 mm thickness |
| 458 | 4.5.1:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts &nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness |
| 459 | 4.5.2:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts &nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 460 | 4.5.3:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts &nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness |
| 461 | 4.5.5:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts &nuts, painting suspenders etc as required.375 mm width X 50 mm depth X 2.0 mm thickness |
| 462 | OD357052/2025-2026:Supply. fabrication and installation of Transformer / DG Set / Panel Board mounting and cable tray supports using MS C Channels of adequate size painted with two coats of epoxy primer and two coats of black / grey / other approved colour epoxy paint. The scope also the includes the supply and installation of necessary rectangular / square plates, anchor fasteners, bolts, nuts, round and spring washers, screws etc. complete as required |
| 463 | OD357053/2025-2026:Supply. fabrication and installation of MS Chequered Plates of 6mm thickness painted with two coats of epoxy primer and two coats of black / grey / other approved colour epoxy paint to use directly above the cable trenches or with cable trenches having existing M.S Angles / Flats / C Channel supports etc. complete as required |
| 464 | OD357054/2025-2026:Supply and providing Extension of DG exhaust pipeline using 100mm dia B Class MS pipes with all required accessories like bends, coupling, flanges, flexibles, bolts, nuts etc. using already fabricated and duly painted existing MS or SS support structure etc. and painting the same using 600 Deg.C Heat Resistant Aluminium paints etc. complete as required |
| 465 | OD357055/2025-2026:Supply and providing Extension of DG exhaust pipeline using 150mm dia B Class MS pipes with all required accessories like bends, coupling, flanges, flexibles, bolts, nuts etc. using already fabricated and duly painted existing MS or SS support structure etc. and painting the same using 600 Deg.C Heat Resistant Aluminium paints etc. complete as required |
| 466 | OD357056/2025-2026:Supply and providing Extension of DG exhaust pipeline using 125mm dia B Class MS pipes with all required accessories like bends, coupling, flanges, flexibles, bolts, nuts etc. using already fabricated and duly painted existing MS or SS support structure etc. and painting the same using 600 Deg.C Heat Resistant Aluminium paints etc. complete as required |
| 467 | OD357057/2025-2026:Supply and providing Thermal insulation of DG exhaust pipeline by rock wool, chicken wire mesh, cladding by 24 SWG aluminium sheets including the bends / flanges therein by fixing appropriate size Stainless Steel bolts, nuts, round and spring washers or screws etc. complete as required |
| 468 | 90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. |
| 469 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 470 | 1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 471 | OD357155/2025-2026:Supply and fixing of 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch with connections on the existing GI box with modular plate and cover in front on surface or in recess etc. complete as required. (Combined Socket) |
| 472 | 1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 473 | 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 474 | 1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 475 | 1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm) |
| 476 | 90.10.1.3:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface |
| 477 | 90.10.1.5:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface |
| 478 | 90.10.1.6:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )8 module moulded plastic box on surface |
| 479 | 90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator |
| 480 | 90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket |
| 481 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 482 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 483 | 1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm |
| 484 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 485 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 486 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 487 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 488 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 489 | 1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 490 | 1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module |
| 491 | 1.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module |
| 492 | 1.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module |
| 493 | OD357231/2025-2026:Supply and laying of 1.1kV Grade Heat Resistant Flame Retardant (HRFR) PVC insulated multi core copper conductor cables of the following sizes conforming to IS: 694 and laying through existing PVC wall trunking / ducts, cable trays using cable ties or clamps, clamping through walls using Aluminium Strip / spacer saddles etc. complete as required. 1C X 35 Sq.mm |
| 494 | OD357232/2025-2026:Supply and laying of 1.1kV Grade Heat Resistant Flame Retardant (HRFR) PVC insulated multi core copper conductor cables of the following sizes conforming to IS: 694 and laying through existing PVC wall trunking / ducts, cable trays using cable ties or clamps, clamping through walls using Aluminium Strip / spacer saddles etc. complete as required. 4C X 25 Sq.mm |
| 495 | OD357233/2025-2026:Supply and laying of 1.1kV Grade Heat Resistant Flame Retardant (HRFR) PVC insulated multi core copper conductor cables of the following sizes conforming to IS: 694 and laying through existing PVC wall trunking / ducts, cable trays using cable ties or clamps, clamping through walls using Aluminium Strip / spacer saddles etc. complete as required. 1C X 25 Sq.mm |
| 496 | OD357234/2025-2026:Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 497 | OD357235/2025-2026:Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 498 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm |
| 499 | 90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm |
| 500 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 501 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 502 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 503 | OD357274/2025-2026:Supply and installtion of 36W Low Glare High Efficiency Square Recess Mounted LED Flat Panel Light fittings with all required accessories. The light shall have the specification of Rated Voltage 240V, Operating Voltage Range 140V to 270V, Frequency 50Hz, Operating Temperature -10 Deg.C to +45 Deg.C, Input Current 0.152A to 0.170A, Rated Wattage 36W, Power Factor greater than or equal to 0.95, THD less than or equal to 10%, Surge Protection Inbuilt, 5 Years Onsite Parts Replacement Warranty etc. complete as required |
| 504 | OD357275/2025-2026:Supply and installtion of 36W Low Glare High Efficiency Square Surface Mounted LED Flat Panel Light fittings with Stainless Steel bolts, nuts, round and spring washers or screws and all other required accessories. The light shall have the specification of Rated Voltage 240V, Operating Voltage Range 140V to 270V, Frequency 50Hz, Operating Temperature -10 Deg.C to +35 Deg.C, Input Current 0.152A to 0.170A, Rated Wattage 36W, Power Factor greater than or equal to 0.95, THD less than or equal to 10%, Surge Protection Inbuilt, 5 Years Onsite Parts Replacement Warranty etc. complete as required |
| 505 | OD357276/2025-2026:Supply and installation of 24W Low Glare High Efficiency Square Surface Mounted 1x1 LED Flat Panel Light fittings with Stainless Steel bolts, nuts, round and spring washers or screws and all other required accessories. The light shall have the specification of Rated Voltage 240V, Operating Voltage Range 140V to 270V, Frequency 50Hz, Operating Temperature -10 Deg.C to +40 Deg.C, Input Current 0.110A, Rated Wattage 24W, Power Factor greater than or equal to 0.95, THD less than or equal to 10%, Surge Protection Inbuilt, 5 Years Onsite Parts Replacement Warranty etc. complete as required |
| 506 | OD357277/2025-2026:Supply and installation of 18W Low Glare High Efficiency Square Surface Mounted 1x1 LED Flat Panel Light fittings with Stainless Steel bolts, nuts, round and spring washers or screws and all other required accessories. The light shall have the specification of Rated Voltage 240V, Operating Voltage Range 140V to 270V, Frequency 50Hz, Operating Temperature -10 Deg.C to +40 Deg.C, Input Current 0.090A, Rated Wattage 18W, Power Factor greater than or equal to 0.95, THD less than or equal to 10%, Surge Protection Inbuilt, 5 Years Onsite Parts Replacement Warranty etc. complete as required |
| 507 | OD357278/2025-2026:Supply and installation of 18W Low Glare High Efficiency Round Surface Mounted LED Flat Panel Light fittings with Stainless Steel bolts, nuts, round and spring washers or screws and all other required accessories. The light shall have the specification of Rated Voltage 240V, Operating Voltage Range 140V to 270V, Frequency 50Hz, Operating Temperature -10 Deg.C to +35 Deg.C, Input Current 0.064A to 0.090A, Rated Wattage 18W, Power Factor greater than or equal to 0.95, THD less than or equal to 10%, Surge Protection Inbuilt, 5 Years Onsite Parts Replacement Warranty etc. complete as required |
| 508 | 90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture |
| 509 | 90.3.20.4:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 2X20W LED Lamp with box type fixture |
| 510 | 90.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture |
| 511 | 90.3.21.4:Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 2x20W LED Lamp with box type fixture |
| 512 | 90.3.24.4:Supply & installation of light fittings suspended on ball & socket arrangement with 19 mm down rod Supply, conveyance, installation, testing and commissioning the light fittings of following types made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required.1200 mm 2X20W LED Lamp with box type fixture |
| 513 | 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 514 | OD357295/2025-2026:Supply and installation of 10W LED Bulk Head Light fittings with Stainless Steel bolts, nuts, round and spring washers or screws and all other required accessories. The light shall have the specification of Rated Voltage 240V, Operating Voltage Range 140V to 270V, Frequency 50Hz, Operating Temperature -10 Deg.C to +40 Deg.C, Input Current 0.045A, Rated Wattage 10W, Power Factor greater than or equal to 0.95, THD less than or equal to 15%, Surge Protection Inbuilt, 5 Years Onsite Parts Replacement Warranty etc. and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant IS orextending the original wiring etc. complete as required |
| 515 | OD357296/2025-2026:Supply and providing 9W LED Lamp in the existing PVC batten/ angle holder |
| 516 | 19.1:Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required: |
| 517 | OD357368/2025-2026:Supply, installation, testing and commissioning 90W, 220V to 240V, 50Hz, 300mm sweep Heavy Duty Metal Exhaust fan with rated speed of 2300 revolution per minute etc. in the existing holes using necessary Stainless Steel bolts, nuts, round and spring washers or screws and giving connections with required length of 24/0.20mm 3 core copper conductor flex wire conforming to relevant IS or extending the original wiring etc. complete as required |
| 518 | OD357369/2025-2026:Supply, installation, testing and commissioning 45W, 220V to 240V, 50Hz, 150mm sweep Medium Duty Metal Exhaust Fan with rated speed of 2300 revolution per minute etc. in the existing holes using necessary Stainless Steel bolts, nuts, round and spring washers or screws and giving connections with required length of 24/0.20mm 3 core copper conductor flex wire conforming to relevant IS or extending the original wiring etc. complete as required |
| 519 | 90.5.1.3:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell |
| 520 | 90.5.1.7:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Gong bell 100mm-without MS box |
| 521 | OD357372/2025-2026:Supply, installation, testing and commissioning 45W, 220V to 240V, 50Hz, 150mm sweep Medium Duty Metal Exhaust Fan with rated speed of 2300 revolution per minute etc. in the existing holes using necessary Stainless Steel bolts, nuts, round and spring washers or screws and giving connections with required length of 24/0.20mm 3 core copper conductor flex wire conforming to relevant IS or extending the original wiring etc. complete as required |
| 522 | 90.15.3.5:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 7 Meters |
| 523 | 90.15.3.6:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III double arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 7 Meters |
| 524 | 90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 525 | 90.15.4.3:Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 526 | 90.15.4.6:Supply Conveyance, installation, testing and commissioning of 70W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 527 | 90.3.18.1:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.25 mm dia with HG company fabricated clamps |
| 528 | OD358250/2025-2026:Supply, installation, testing and commissioning of Double Conversion Online Modular UPS Frame with Integrated 3U rackcooling, DC inverter, R410A Closedloop cooling |
| 529 | OD358251/2025-2026:Supply, installation, testing and commissioning of 5kVA UPS (9PX Series) × 1 Unit - 5kVA/4.5kW, ABM, NETWORKM2 SNMP card included. Input Power Factor 0.99 at Full Load Output Power Factor 1.0 Input Voltage Range 320V to 460V with Cut-off THDi less than or equal to 3% THDv less than 0.5% in linear Load and less than 1% in Non-linear Load DC to AC Efficiency 96% Ambient Temperature 0 to 40 Deg.C Generator Compatibility Pure Sine Wave Battery Over Charge and Under Charge Cut-off Bypass Arrangement Digital Indicationsof Input Voltage, Input Current, Output Voltage, Output Current and Temperature LCD and LED Display EN / IEC 620401 for General Safety Compatibility EN / IEC 620402 for Electromagnetic Compatibility EN / IEC 620403 for Performance EN / IEC 620404 or PEP for Environmental Compatibility etc. complete as required. (There shall be a Service Centre in the district from the UPS OEM itself) ( EATON or equivalent) |
| 530 | OD358252/2025-2026:Supply, installation, testing and commissioning of battery bank consisting of 12V 26Ah Rated SMF battery of 16 Nos for a minimum backup of 30 minutes with all accessories like interconnecting cables, copper sockets including crimping and providing connections etc.complete as required |
| 531 | OD358253/2025-2026:Supply, fabrication and installation of Solar Photo Voltaic module mounting Structure using 2.0x2.0 (Inches) and 1.5x1.5 (Inches) 304 Grade 16 Gauge Stainless Steel square tube and 4.0x4.0 (Inches) 304 Grade 16 Gauge Stainless Steel square base plates for mounting the structure to withstand sufficient wind loads. The scope also includes the supply and installation of suitable Stainless Steel clamps, bolts, nuts, round and spring washers or other fasteners, fixtures with leak-proof sealants for mounting modules with fabrication, grinding and finishing with required abrasives to withstand extreme corrosion and rust resistance under the action of wind, water and moisture etc. complete as required as per the local site conditions |
| 532 | OD358254/2025-2026:Supply, installation, testing and commissioning of Solar Photo Voltaic Framed Dual Glass Bifacial module per watt in the range of 545W to 575W with mandatory BIS / IEC Certifications (*The rate to be quoted here is for 1W only |
| 533 | OD358255/2025-2026:Supplying and laying of 6.0 Sq.mm Photo Voltaic Solar cables with a nominal DC voltage of a 1.5kV designed to withstand the demanding environmental conditions that arise in any fixed, mobile, roof or architecturally integrated photovoltaic installation through the existing conduit with all necessary accessories |
| 534 | OD358257/2025-2026:Supply, installation, testing and commissioning of 1 Pair of high quality MC4 Photovoltaic Module Connectors used for low-voltage DC applications up to 1500V, conforming to IEC 62852:2014 (Connectors for DC Application in photovoltaic systems - Safety requirements and tests) etc. complete as required |
| 535 | OD358258/2025-2026:Supply and installation of 304 Grade Stainless Steel Cable Tie of size 300mm x 4.6mm (12 Inch) used for Roof Top Solar and Industrial Purpose etc. The tie shall have the specifications of high strength, zip and self locking, shiny surface, smooth rounded edges to ensure safety, antioxidative, anti-caustic, high temperature resistant, cold resistant etc. complete as required |
| 536 | OD358259/2025-2026:Supply and installation of Nylon 66 Cable Tie of size 300mm x 3.6mm (12 Inch) used for Roof Top Solar and Industrial Purpose etc. The tie shall have the specifications of UV resistance, high strength, zip and self locking, flammability UL 94 HB, operating temperature -40 Deg.C to +140 Deg.C, RoHS compliance etc. complete as required |
| 537 | OD358260/2025-2026:Supply and installation of Nylon 66 Cable Tie of size 150mm x 2.5mm (6 Inch) used for Roof Top Solar and Industrial Purpose etc. The tie shall have the specifications of UV resistance, high strength, zip and self locking, flammability UL 94 HB, operating temperature -40 Deg.C to +140 Deg.C, RoHS compliance etc. complete as required |
| 538 | OD358261/2025-2026:Supply, installation, testing and commissioning of Wall Mounting DC Distribution Board made of Thermoplastic Polycarbonate Glass Fibre Reinforced material for 1000V DC supply system having Design Standard according to IEC 60 364-7-712 and IEC 61439-1 and 2, Design Temperature of 50 Deg.C, IP 65 Degree |
| 539 | OD358262/2025-2026:Supplying and fixing of following sizes of PVC wall trunking / duct system with base perforation, cable retaining clip, 1 Nos of insertable partitions etc. complete along with all accessories in surface / recess including cutting the wall and making good the same in case ofrecessed installation etc. complete as required. 60 X 110mm (Height X Width) |
| 540 | OD358263/2025-2026:Supply, installation, testing and commissioning of String Inverter at any combination of total output power of 50KW conforming to Central Electricity Authority, Electrical Inspectorate and KSEBL Standards with necessary Anti - Islanding property, IS / IEC Certifications etc. |
| 541 | OD358264/2025-2026:Supply, installation, testing and commissioning of Wall Mounting AC Distribution Board made of Thermoplastic Polycarbonate Glass Fibre Reinforced material for 415 V, 3 Phase, 4 Wire, 50Hz AC supply system having Design Standard according to IEC 60364-7-712 and IEC 61439-1 and 2, Design Temperature of 50 Deg.C, IP 65 Degree of Protection (EN 60529), RAL 7035 (Self Finish Grey) Finish shade for enclosure with all components and connections including cable, lugs, sleeves, ferrules, screws and other necessary accessories |
| 542 | OD358265/2025-2026:Supply and installation of periodical PV Module cleaning pipe line system using 25mm CPVC SDR 11 Pipe with all necessary accessories and clamping in walls using Stainless Steel saddles and screws of which spacing between 30cm to 60cm including all minor civil works etc.complete as required |
| 543 | OD358266/2025-2026:Supply, installation, testing and commissioning of Twin Type LED Based Aviation Obstruction Light (AOL) with standard housing Aluminium Pole and Bracket. The lamp shall have the specifications like Red Colour, Day-Night Photocell Sensor, IP 65 Rating etc. according to the height of the building with all other necessary accessories conforming to Government of India Civil Aviation, CPWD / PWD, Electrical Inspectorate and NBC Standards etc. complete as required |
| 544 | 2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 545 | 2.22:Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 546 | OD358267/2025-2026:Supply and fixing 2Kg Dry Chemical Powder (DCP) type fire extinguisher complete with Gun Metal cap, hose with squeeze grip nozzle, wall fixing brackets conforming to BIS: 2171 and with ISI mark etc. complete as required |
| 547 | OD358268/2025-2026:Supply and providing a set of 2 Nos. 9.5 Litre capacity GI bucket painted in post office red colour with prior coat of red oxide paint and written with white paint FIRE and mounted on MS angle iron frame with bracket of appropriate size and capacity including filling sand etc.complete as required |
| 548 | OD358269/2025-2026:Supply and providing 11kV tested discharge rod conforming to IEC 61230 : 2008 etc. complete as required |
| 549 | OD358270/2025-2026:Supply and providing 1 pair of 11kV tested rubber gloves conforming to IS 4770 : 1991 etc. complete as required |
| 550 | OD358271/2025-2026:Supply and providing Electrical Grade Rubber Mat of size 2m x 1m having 12mm thickness in front of HT Panels and Transformer conforming to IS 15652 : 2006 standard etc. complete as required |
| 551 | OD358272/2025-2026:Supply and providing Electrical Grade Rubber Mat of size 2m x 1m having 6mm thickness in front of Panel Boards and DBs conforming to IS 15652 : 2006 standard etc. complete as required |
| 552 | OD358273/2025-2026:Supply and fixing Laminated Safety Instruction Chart duly mounted on a good frame work etc. complete as required |
| 553 | OD358274/2025-2026:Supply and fixing Laminated Shock Treatment Chart duly mounted on a good frame work etc. complete as required |
| 554 | OD358275/2025-2026:Supply and providing First Aid Box as approved by St. John Ambulance Brigade / Indian Red Cross conforming to IS 2217 : 1963 etc. complete as required |
| 555 | OD358276/2025-2026:Supply and providing tested Industrial Safety Helmet conforming to IS 2925 : 1984 etc. complete as required |
| 556 | OD358277/2025-2026:Painting letters or figures of 4.5cm / 2.5cm sizes with enamel paint as identification mark to various compartments/doors of HT Panels, Transformer, DG Set, Panel Boards, Distribution Boards etc. complete as required (*The rate to be quoted here is for 1 Nos of Letters or Figures Only) |
| 557 | OD358278/2025-2026:Supply, installation, testing and commissioning of Three Phase HT TOD CT Operated Bidirectional Net Meter conforming to the relevant Electrical Inspectorate, KSERC and KSEBL Standards. The scope also includes the supply and installation of mounting screws, supply ofrequired sizes of 1.1kV Grade Flame Retardant Low Smoke (FRLS) or Heat Resistant Flame Retardant (HRFR) PVC insulated single core copper conductor cable for providing complete connections and copper sockets (banana / palm / pin / ring) including crimping etc. complete as required |
| 558 | OD358279/2025-2026:Supply, installation, testing and commissioning of Energy Meter after getting it duly tested from Electrical Inspectorate / TMR KSEBL |
| 559 | OD358280/2025-2026:Supply, installation, testing and commissioning of CTs after getting it duly tested from Electrical Inspectorate / TMR KSEBL. Up to and including 250/5A CL:0.5S 5VA Resin Cast CT |
| 560 | OD358281/2025-2026:Supply, installation, testing and commissioning of 5HP Three Phase Openwell Submersible Pump suitable for 34m to 50m Head and 1 LPS to 4.5 LPS discharge respectively etc. complete as required @40m 228 LPM or other within the above range |
| 561 | OD358282/2025-2026:Supply, installation, testing and commissioning of 2.0 TR Inverter Type BEE 3 Star Rated High Wall Split Air Conditioner Unit with Copper Condenser, Cordless Remote Control, R 32 Refrigerant, Copper Pipe of 3m using Stainless Steel bolts, nuts, round and spring washers orscrews, Heavy Duty Stand for Outdoor Unit etc. complete with connections as required |
| 562 | OD358283/2025-2026:Supply, installation, testing and commissioning of 1.5 TR Inverter Type BEE 3 Star Rated High Wall Split Air Conditioner Unit with Copper Condenser, Cordless Remote Control, R 32 Refrigerant, Copper Pipe of 3m using Stainless Steel bolts, nuts, round and spring washers orscrews, Heavy Duty Stand for Outdoor Unit etc. complete with connections as required |
| 563 | OD358284/2025-2026:Supply, installation, testing and commissioning of Wall Mounting Type Voltage Stabilizer for Air Conditioners up to and including 2.0 TR having Working Voltage Ranging from 170V to 270V, 15A Capacity with Advanced IC Based Design, Intelligent Time Delay System, Thermal Overload Protection, Under / Over Voltage Protection using Stainless Steel bolts, nuts, round and spring washers or screws, 25A / 16A 3 Pin Top for connections etc. complete with connections as required |
| 564 | OD358285/2025-2026:Supply, installation, testing and commissioning of additional Copper Piping System for the existing Split Air Conditioner with all necessary accessories and connections etc. complete as required |
| 565 | OD358286/2025-2026:Supply, installation, testing and commissioning of 10 Passenger Lift (Gear Less and with Machine Room) as per the following.SPECIFICATIONSRated Speed 1 M/sec, Travel 20.0m (Approx.), No of Floor and Entrance Served 5 Floors, 5 Landings (5 Doors) with or without attendant with Micro Processor Controller, Stainless Steel 304 Hairline Cabin with rear side one panel mirror finish and mirror finish false ceiling, Led Lighting, Strong Air Axial Flow Fan with Diffuser and Flooring with 20mm thick Granite Slab, Available Well Size - 1900mm W x 3000mm D, Call Indicator and Position - UP / DN Direction Indication shall be provided at all Landings - LCD Indication, Suitable for operating in 415 V 50 Hz AC Supply System, Indications, Digital Push Buttons and other requirements - Car Position (Inside the Car and at all landings - LCD Indication), Call Indicator (Inside the Car LCD indication), Button for Door Close, Door Open (Inside the Car), Emergency Stop Button (Inside the Car), Flush Mounted Switch for Fan and Light (Inside the Car), Non-stop Button (Inside the car), Battery Operated Emergency LED Lamp with Rechargeable Batteries, Battery Operated Alarm Bell, Intercom Wiring with One Master Unit and Two Slaves, Firemans Switch at Main Lobby, Auto / Attendant Control (Inside the Car), Infrared Door Opening System provided for the entire length, Automatic Rescue Device with an Electronic Controller and with suitable Maintenance Free Batteries. The rescue operation shall act within 10 Seconds of Power Failure. Manual Winding Wheel for Car in case of an Emergency, Automatic Leveling at all Landings etc. complete as requiredSAFETY FEATURES Over Speed Governor, Buffers, Motor Over Speed Protection, Phase Reversal Protection, Single Phase Preventer, Final Limit Switch etc. as per Electrical Inspectorate, IS and other relevant Standards etc. complete as required SCOPE OF WORKSupply and installation of Lift Materials, Minor Civil Works such as Construction of Buffer Block in the Pit Machine Room, Foundation necessary for mounting the Control Panel, Cutting Pockets and Grouting Brackets for Guide Rails, Grouting Boxes for Control Units in the Front Side, Correction of Wall Opening on the Front Side of the Wall, Scaffolding, Door Frame, Supporting Steel, Obtaining Approval andSanction for Energization from Electrical Inspectorate, Free Servicing for 12 months after Handing Over etc. complete as requiredWARRANTYThe Manufacturer / Installer shall carry out Free Maintenance During Warranty Period and also includes Cleaning Lift Equipment, Lubrication of all Parts, Replacing of Lubricating Oil when required, Checking and Adjusting Contacts, Replacing Fusible Items, Alarm etc., Re-charging Batteries in case of Drain / and or Renewing of Batteries, Replacing / Rewinding of Motors if required etc. complete as required. (*All Statutory fees shall be remitted by the Client / Consumer or it shall be reimbursed on the submission of supporting documents) |
| 566 | OD358287/2025-2026:Supply, installation, testing and commissioning of 8 Passenger Lift (Gear Less and with Machine Room) as per the following.SPECIFICATIONSRated Speed 1 M/sec, Travel 20.0m (Approx.), No of Floor and Entrance Served 5 Floors, 5 Landings (5 Doors) with or without attendant with Micro Processor Controller, Stainless Steel 304 Hairline Cabin with rear side one panel mirror finish and mirror finish false ceiling, Led Lighting, Strong Air Axial Flow Fan with Diffuser and Flooring with 20mm thick Granite Slab, Available Well Size - 2000mm W x 1800mm D, Call Indicator and Position - UP / DN Direction Indication shall be provided at all Landings - LCD Indication, Suitable for operating in 415 V 50 Hz AC Supply System, Indications, Digital Push Buttons and other requirements - Car Position (Inside the Car and at all landings - LCD Indication), Call Indicator (Inside the Car LCD indication), Button for Door Close, Door Open (Inside the Car), Emergency Stop Button (Inside the Car), Flush Mounted Switch for Fan and Light (Inside the Car), Non-stop Button (Inside the car), Battery Operated Emergency LED Lamp with Rechargeable Batteries, Battery Operated Alarm Bell, Intercom Wiring with One Master Unit and Two Slaves, Firemans Switch at Main Lobby, Auto / Attendant Control (Inside the Car), Infrared Door Opening System provided for the entire length, Automatic Rescue Device with an Electronic Controller and with suitable Maintenance Free Batteries. The rescue operation shall act within 10 Secondsof Power Failure. Manual Winding Wheel for Car in case of an Emergency, Automatic Leveling at all Landings etc. complete as requiredSAFETY FEATURES Over Speed Governor, Buffers, Motor Over Speed Protection, Phase Reversal Protection, Single Phase Preventer, Final Limit Switch etc. as per Electrical Inspectorate, IS and other relevant Standards etc. complete as required SCOPE OF WORKSupply and installation of Lift Materials, Minor Civil Works such as Construction of Buffer Block in the Pit Machine Room, Foundation necessary for mounting the Control Panel, Cutting Pockets and Grouting Brackets for Guide Rails, Grouting Boxes for Control Units in the Front Side, Correction of Wall Opening on the Front Side of the Wall, Scaffolding, Door Frame, Supporting Steel, Obtaining Approval andSanction for Energization from Electrical Inspectorate, Free Servicing for 12 months after Handing Over etc. complete as requiredWARRANTYThe Manufacturer / Installer shall carry out Free Maintenance During Warranty Period and also includes Cleaning Lift Equipment, Lubrication of all Parts, Replacing of Lubricating Oil when required, Checking and Adjusting Contacts, Replacing Fusible Items, Alarm etc., Re-charging Batteries in case of Drain / and or Renewing of Batteries, Replacing / Rewinding of Motors if required etc. complete as required. (*All Statutory fees shall be remitted by the Client / Consumer or it shall be reimbursed on the submission of supporting documents) |
| 567 | OD358288/2025-2026:Supply, installation, testing and commissioning of Surface Mounted Infrared Presence Sensor with all accessories having Detection Range 360 Degrees, Detection distance up to 20m, Time Delay Minimum 10sec. (+ or - 3sec.) Maximum 30min. (+ or - 2min.), Rated Voltage 220 to 240V AC, Frequency 50/60Hz, Installation Height 2.2 to 6m, Rated Load Maximum 2000W etc. complete as required |
| 568 | OD358289/2025-2026:Supply, installation, testing and commissioning of Surface Mounted Microwave Sensor with all accessories having Detection Range 360 Degrees, Detection distance up to 8m, Time Delay Minimum 10sec. (+ or - 3sec.) Maximum 12min. (+ or - 1min.), Rated Voltage 220 to 240V AC 50/60Hz, Installation Height 2 to 6m, Rated Load Maximum 2000W etc. complete as required |
| 569 | OD358290/2025-2026:Supply, installation, testing and commissioning of Surface Mounted PIR Motion Sensor with all accessories having Detection Range 360 Degrees, Detection distance up to 6m, Time Delay Minimum 10sec. (+ or - 3sec.) Maximum 15min. (+ or - 2min.), Rated Voltage 220 to 240V AC, Frequency 50/60Hz, Installation Height 2.2 to 6m, Rated Load Maximum 2000W etc. complete as required |
| 570 | Estimate(Electrical-Fire Fighting) |
| 571 | 18.2.6:a)Supplying,installation,testing and commissioning of Diesel Engine driven Main Fire Pump suitable for Automatic operation and consisting of following, complete in all respect , as required :(Diesel Driven Pump)b) Horizontal type, Multi stage ,centrifugal, split Pump of Cast Iron body and bronze impeller with stainless steel shaft ,mechanical seal conforming to IS 1520. C) Suitable HP ,1500rpm,water cooled with radiator,diesel engine conforming to relevant IS standard complete with auto starting mechanism 12/24 V Electric starting equipment,diesel tank, exhaust pipe extended upto 10m outside pump house duly insulated with 50 mm thick glass wool with 1 mm thick Al sheet cladding residential silencer, instruments and protection as per standard specifications, stop solenoid for Auto stop in the event of fault with audio indications, painted with post office red colour etc as required.d) M.S Fabricated common base plate coupling, coupling guard ,foundation bolts etc as required.e) Suitable cement concrete foundation duly plastered with Anti vibration pads2280 lpm at 56 m head |
| 572 | 18.1.6:a)Supplying,installation,testing and commissioning of Electric driven Main Fire Pump suitable for Automatic operation and consisting of following, complete in all respect , as required :b) Horizontal type, Multi stage ,centrifugal, split casing Pump of Cast Iron body and bronze impeller with stainless steel shaft ,mechanical seal conforming to IS 1520. C) Suitable HP Squirrel Cage Induction Motor, TEFC, Synchronous speed 1500rpm suitable for operation on 415 V 3 phase 50 HZ AC supply with IP55 Protection for enclosure ,horizontal foot mounted type with class F insulation, conforming to IS 325.d) M.S Fabricated common base plate coupling, coupling guard ,foundation bolts etc as required.e) Suitable cement concrete foundation duly plastered with Anti vibration pads2280 lpm at 56 m head |
| 573 | 18.3.6:a)Supplying, installation, testing and commissioning of Electric driven Pressurisation Pump suitable for Automatic operation and consisting of following, complete in all respect , as required :(Jockey Pump)b) Horizontal type, Multi stage ,centrifugal, split casing Pump of Cast Iron body and bronze impeller with stainless steel shaft ,mechanical seal conforming to IS 1520. C) Suitable HP Squirrel Cage Induction Motor, TEFC type suitable for operation on 415 V 3 phase 50 HZ AC supply with IP55 Protection for enclosure ,horizontal foot mounted type with class F insulation, conforming to IS 325. d)M.S Fabricated common base plate coupling, coupling guard ,foundation bolts etc as required.e) Suitable cement concrete foundation duly plastered with Anti vibration pads300lpm at 56m Head |
| 574 | 18.5.1:Fabrication, supply, installation, testing and commissioning of Electrical Control Panel of cubicle construction Floor mounted type fabricated out of 2 mm thick CRCA sheet compartmentalised with hinged lockable doors, dust vermin proof, powder coated of approved shade after 7 tank treatment process cable alleying interconnection with suitable size copper conductor cable or solid copper strip having switchgearsand accessories, mopuntigs and internal wiring, earth terminals, numbering etc., complete in all respects suitable for main fire pump , pressurisation pump and diesel pump set complete as per CPWD specification with following incoming and outgoings suitable for operation of 415 V, 3 phase, 50 Hz, AC supply with enclosure protection class IP 42 as required: INCOMING : 250A, 50kA 4P MCCB ,Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter 0-250A with selector switch and CTs etc. LED Type RYB phase indicating Lamps ,ON/OFF, Trip indicating lamps set of Cu Bus Bar 300A . OUT GOING:(Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) MAIN FIRE PUMP: 125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. JOCKEY PUMP : 63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. DIESEL ENGINE CONTROL: Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification |
| 575 | OD349992/2025-2026:Supply and drawing 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipment including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc. as required - 1.50 sq. mm single run with required sockets & numbering ferrule. |
| 576 | OD349983/2025-2026:Supply and laying 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipment including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc. as required.2.50 sq mm single run with required sockets & numbering ferrule. |
| 577 | OD349973/2025-2026:Supply and laying 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipment including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc. as required.4.00 sq mm single run without sockets. |
| 578 | OD349975/2025-2026:Supply and laying 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipment including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc. as required.6.00 sq. mm single run without sockets |
| 579 | 90.12.7.12:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 4 sq mm with factory made clamp |
| 580 | 90.12.7.17:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 35 sq mm with factory made clamp |
| 581 | 90.12.7.30:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm |
| 582 | OD349986/2025-2026:Supplying siemens / tropodur type nickel plated single compression brass cable gland for PVC insulated and PVC sheathed armoured aluminium/ copper conductor cable 1.1 KV grade, and making end termination suitable for 2/ 3/ 3½/ 4 core cable of the following sizes as required - 4 sq.mm |
| 583 | 9.1.9:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 25 sq. mm (25mm) |
| 584 | 9.1.23:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm) |
| 585 | OD349987/2025-2026:Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required - 4 sq. mm with 12 mm wide x 1 mm thick clip |
| 586 | OD349967/2025-2026:Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required - 25 sq. mm with 20 mm wide x 1.20 mm thick clip |
| 587 | 18.20:supplying and fixing air vessel made of 250 mm dia 8 mm thick MS sheet , 1200 mm in height with Air release valve on top and flanged connection to riser , drain arrangement with 25 mm dia Gun metal wheel valve with required accessories , pressure guage and painting with synthetic enamel paint of approved shade as required. |
| 588 | OD349974/2025-2026:Supply, installation, testing and commissioning of Pressure Gauges |
| 589 | 18.22:Providing and fixing of pressure switch in MS pipeline including connection etc as required: |
| 590 | 18.7.1:Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:25 mm dia |
| 591 | 18.7.2:Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:32 mm dia |
| 592 | 18.7.3:Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:40 mm dia |
| 593 | 18.7.4:Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:50 mm dia |
| 594 | 18.7.6:Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:80mm dia |
| 595 | 18.7.7:Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:100mm dia |
| 596 | 18.7.8:Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:150mm dia |
| 597 | 18.7.9:Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:200mm dia(Wall thickness 6.3mm) |
| 598 | OD349972/2025-2026:Supply and providing Hose Cabinet Suitable for accommodating two nos. of 15 mtr. long fire hose |
| 599 | 18.18.2:Supplying and fixing 63 mm dia gun etal short metal branch pipe ith 20 mm nominal interanal diameter size nozzle conforming to IS 903 suitable for Instantaneous connection to Interconnect hose pipe coupling as required:Stainless steel (Grade 304) |
| 600 | 18.10.1:Supplying and fixing single headed external yard hydrant valve with one no: 63 mm dia instantaneous FM Gun metal or stainless steel coupling and cast iron wheel, ISI marked ISI marked conforming to IS 5290(Type A) with blank Gun metal or Stainless steel cap and chain as required:Single headed Gunmetal |
| 601 | 18.16.1:Supplying and fixing 63 m dia,15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required: Gun Metal |
| 602 | 18.17.1:Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.a) 20 mm nominal Internal dia water hose thermoplastic(Textile reinforced) type-2 as per IS:12585b) 20 mm nominal internal dia gun metal globe valve &nozzlec) Drum and brackets for fixing the equipments on wall.d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m |
| 603 | 18.11.4:Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers ,gaskets conforming to IS 13095 of following sizes as required:80 mm dia |
| 604 | 18.11.5:Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers ,gaskets conforming to IS 13095 of following sizes as required:100 mm dia |
| 605 | 18.11.6:Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers ,gaskets conforming to IS 13095 of following sizes as required:150 mm dia |
| 606 | 18.11.7:Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers ,gaskets conforming to IS 13095 of following sizes as required:200 mm dia |
| 607 | 18.14.4:Providing,installation,testing and commissioning of non-return valve of following sizes conforming to IS :5312 complete with rubber gasket, GI bolts , nuts, washers etc as required.80mm dia |
| 608 | 18.14.5:Providing,installation,testing and commissioning of non-return valve of following sizes conforming to IS :5312 complete with rubber gasket, GI bolts , nuts, washers etc as required.100 mm dia |
| 609 | 18.14.7:Providing,installation,testing and commissioning of non-return valve of following sizes conforming to IS :5312 complete with rubber gasket, GI bolts , nuts, washers etc as required.150mm Dia |
| 610 | 18.15.4:Providing, installation ,testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel , Grade 304,sheet with3 mm dia holes with stainless steel flange.200 mm dia |
| 611 | OD349968/2025-2026:Supplying, installing, testing and commissioning of Cast Iron Ball Valves with fittings of screwed end type - 50mm Dia. |
| 612 | OD349984/2025-2026:Supplying, installing, testing and commissioning of Cast Iron Ball Valves with fittings of screwed end type - 25mm Dia. |
| 613 | OD349965/2025-2026:Supply, installation, testing and commissioning of single acting Air Release Valve with screwed inlet 25mm dia. etc. |
| 614 | 18.19.1:Supplying and fixing fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia M.S. Pipe connection conforming to IS 904 as required:2 way-100 mm dia M.S.Pipe |
| 615 | OD349985/2025-2026:Supply and installation of the following sizes of cast iron Foot valve with strainer to the pump sets complete with bolts, nut gaskets if any as required etc. - 100 mm dia. |
| 616 | 18.21.1:Providing,fixing, testing and commissioning of 15 mm dia quatzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Pendent Sprinkler |
| 617 | OD349980/2025-2026:Supplying, installing, testing and commissioning of flow switch installed on the sprinkler main distribution line connected to the main sprinkler annunciation panel located in the ground floor. 80 mm dia. |
| 618 | OD349982/2025-2026:Supplying, installing, testing and commissioning of 10 zone annunciation panel. |
| 619 | OD349988/2025-2026:Supplying, installing, testing and commissioning of 100mm Installation Control Valve with gong, bell, trim & complete kit. |
| 620 | OD349977/2025-2026:Supplying, installing, testing and commissioning of microprocessor based main fire alarm control panel of 22 zones capacity with visual LED indications for fire/fault alarms, signals and should have stage alarm facility with maintenance free battery back up for 24 hours normal operation and 15 minute alarm operation. The panel shall be fabricated by MS sheet and powder coated both inside and out side door shall be glass fronted type with locking arrangement as per specification. |
| 621 | 17.1.1:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of heat detector operating at 54ºC / 57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required. |
| 622 | 17.1.2:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of smoke detector with built-in LED and mounting base complete with all connections etc. as required. |
| 623 | 17.1.4:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 624 | OD349990/2025-2026:Supplying, installing, testing and commissioning of Electronic dual tone Hooter(sounder) as per standard specification. |
| 625 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 626 | 17.5.2:CABLING & WIRINGSupplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 627 | 90.6.4.1:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 1 Run |
| 628 | OD349993/2025-2026: Supplying and fixing of Dry chemical powder type fire extinguisher of 4 kgs. capacity, with initial filling in brand new Cylinder with powder coated finish fitted with Gun metal union, discharge hose, wall mounting bracket etc. complete confirming to IS.2171 |
| 629 | OD349991/2025-2026: Supply, installation, testing and commissioning of CO2 type fire extinguisher with 4.5 kg. capacity complete with installation brackets with ISI mark IS:15222 |
| 630 | OD349979/2025-2026:Supply, Installation, Testing and Commissioning of solid state Amplifier of 120 W RMS out put in rack, including necessary control wires, jacks etc. complete as required |
| 631 | OD349966/2025-2026:Supply, Installation, Testing and Commissioning of Micro-processor based talk back announcing console suitable for selecting 10 zones, having keypad for zone selection, LED indication including TB switching unit, Main Distribution Box & 6U Rack complete in all respect to commission the project. |
| 632 | OD349970/2025-2026:Supply & erection of MICROPHONE for Intelligible, crisp and bright sound suitable for all type of PA applications supplied with quick detachable holder with 3-pin professional XLR connector & 6 mtrs. Twin core shielded low noise cable. |
| 633 | OD349971/2025-2026:Supply, erection, testing and commissioning of 6 Watt Wall mounted type Speaker for PA System. |
| 634 | OD349989/2025-2026:Supply, erection, testing and commissioning of Talk back field device . |
| 635 | OD349969/2025-2026:Supply and providing emergency fire escape lighting system consisting 2 nos lamp ,7 AH FMF battery charging unit ,exit sign display etc. in MS enclosure |
| 636 | OD349981/2025-2026:Supply & erection of Glow Sign Board made of 3mm thick PVC foam board for each floor 12" x 4" (appropriate places) |
| 637 | OD349978/2025-2026:Supply & erection of Assembly Point sign board of size 16" x 16" |
| 638 | OD349976/2025-2026:Supply & erection of Fire Escape route in each floor having size 12" x 16" made of 3mm thick acrylic sheet with glass frame |
| 639 | Estimate(Electronics Work) |
| 640 | OD349997/2025-2026:Supply and commissioning of SC 12 Port Duplex EFA Fiber Patch Panel Rack Mount |
| 641 | OD349995/2025-2026:Supply and commissioning of SC 6 Port Duplex EFA Fiber Patch Panel Rack Mount |
| 642 | OD349999/2025-2026:Supply and commissioning of SC duplex SM adaptor |
| 643 | OD349996/2025-2026:Supply and commissioning of SC Pigtail SM OS2 1mtr |
| 644 | OD349998/2025-2026:Supply and commissioning of SC/PC-LC/PC 3m OS2 Single Mode Duplex LSZH Patch Cord |
| 645 | OD349994/2025-2026:Supply and commissioning of 6 Core OS2 SM Central Loose Tube Armoured External Cable (Approved Makes-Molex/Panduit, Beldon, Siemon) |
| 646 | OD350031/2025-2026:Supply and installation of 24 Port POE switch 24-Port 10/100/1000 Base-T auto-sensing PoE+ports, 4 dedicated 100/1000 Base-X Fiber SFP ports, Bandwidth:56 Gbps non blocking, Acoustic noise (ANSI-S10.12): 33.42 dBA, Mean Time between Failures(MTBF): 1,071,896 hours, Heat Dissipation (at AC 97VAC/47Hz and full PoE load): 1501.3 Btu/H (internal PS), Forwarding modes: Store-and -Forward, 4 Priority queues, Priority queuing: Weighted Round Robin (WRR), MAC Address database size: 16,000 media access control (MAC) addresses, VLAN: 256, Approved Makes- NETGEAR/ Juniper/ Allied Telesis |
| 647 | OD350041/2025-2026:Supply and commissioning of 1U Metal Cable Management with cover |
| 648 | OD350033/2025-2026:Supply and Installation of 42 U floor mount Rack 1000x1200 size with full accessories Approved Makes- Netrack/ Rittal |
| 649 | OD350030/2025-2026:Supply and Installation of 15 U wall mounted Rack 500x550 size with full accessories Approved Makes- Netrack/Rittal |
| 650 | OD350008/2025-2026:"Supply and Installation of Rack Mountable 16 port L3 Manageable Stackable OFC switch with 16 nos of 1/10 BaseT ports, 5 year warranty. Approved Makes- NETGEAR/ Juniper/ Allied Telesis" |
| 651 | OD350047/2025-2026:"Supply of 22 Port 10G SFP+ L3 Manageable Stackable switch with 2 nos of 1/10 Base_T ports, 5 year warranty.Approved Makes- NETGEAR/ Juniper/ Allied Telesis" |
| 652 | OD350022/2025-2026:"Supply of Layer 2 manageable switch with Non blocking switch fabric having 24 Port 10/100/ 1000 Mbps & 2x1G SFP port. 5 year warranty. Approved Makes- NETGEAR/ Juniper/ Allied Telesis" |
| 653 | OD350005/2025-2026:Supply and installation of 1G Single SFP Module with 5 yr WarrantyApproved Makes- NETGEAR/ Juniper/ Allied Telesis" |
| 654 | OD350009/2025-2026:"Supply of WiFi 6 AX1800 Wireless access point(PoE),802.11AX Long Range,2.4GHz/5GHz-, 2x2 MIMO, with 5 yr Warranty |
| 655 | OD350024/2025-2026:Supply and commissioning of Cat 6 UTP Patch Panel Blank Punch Down 24 Port |
| 656 | OD350051/2025-2026:Supply and commissioning of Category 6 U/UTP Patch Cord LSZH 01M |
| 657 | OD350014/2025-2026:Supply and commissioning of Category 6 U/UTP Patch Cord LSZH 02M |
| 658 | OD350004/2025-2026:Supply and commissioning of Category 6 UTP Keystone Jack Un Shuttered Punch Down 180Deg |
| 659 | OD350013/2025-2026:Supply and commissioning of UK Face Plate Plain 01 Port (86x86mm) |
| 660 | OD350019/2025-2026:Supply, testing and installation of Back Box Make - D Link NBB-011 or equivalent or equivalent |
| 661 | OD350021/2025-2026:Supplying and drawn of UTP 4 pair CAT 6 LAN LSH cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable |
| 662 | OD350018/2025-2026:PBX COMMUNICATION SERVER SYSTEM BASED ON PCM/TDM TECHNOLOGY 100% NON BLOCKING MODEL SARVAM UCS SME ETERNITY GENX12S CONFIGURED FOR 12 CO LINES 02 DIGITAL KEY PHONE PORTS AND 64 EXTENSIONS (Expandable up to 240 ports) |
| 663 | OD350017/2025-2026:Supply and installation of Digital key Phone Metrix 510 |
| 664 | OD350043/2025-2026:Supply, Installation and commissioning of Caller ID phones (DTMF) with glass epoxy coated PCB, Dynamic incoming and outgoing call memory, 6 one touch and 10 two touch memory, LCD contrast and ring volume adjustable, programmable flash and pause,3 numbers AA size Duracell battery, Dual mode FSK/DTMF CLI compatible. |
| 665 | OD350002/2025-2026:Supply and fixing of door type junction boxes with lock and fitted with Krone make modules for 20 pair |
| 666 | OD350006/2025-2026:Supplying and Drawing unarmored PVC insulated and & PVC sheathed copper conductor Telephone Pair Cable conforming to ITD specification for indoor application through the existing conduit. 20pair |
| 667 | 1.18.2:Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair |
| 668 | OD350010/2025-2026:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (Group A). RJ 11 Telephone Jack with shutter |
| 669 | OD350011/2025-2026:Supply and fixing GI Raiseway with cover 1.2 x 50 x 50 mm |
| 670 | OD350016/2025-2026:Supply and fixing GI Raiseway with cover 1.2 x 75 x 75 mm |
| 671 | OD350032/2025-2026:Supply and fixing GI Raiseway with cover 1.2 x 100 x 100 mm |
| 672 | OD350026/2025-2026:Supply and fixing threaded rod M08 |
| 673 | OD350044/2025-2026:Supply and fixing slotted rail 1 mm Electrical |
| 674 | OD350037/2025-2026:Supply and fixing Anchor fastener M 08 |
| 675 | OD350025/2025-2026:Supply nd fixing nut and washer M08 |
| 676 | OD350000/2025-2026:Supply, installation, testing and commissioning of 4MP Dome with following specifications ;1/3” 5 MP progressive scan imager, High resolution 2.8/3.6mm Fixed lens F2.0,True day/night (IR-cut filter) ;Digital Wide Dynamic Range, Low-light performance down to 0.08 lux (color) or 0 lux with IR LEDs on Up to 82 ft (25 m) IR illumination, depending on scene reflectance, H.265 Smart Codec, PoE (802.3af) or 12 VDC support ;Plug-and-play compatible Series (Approved Make: Sony, AXIS, Honewell) (MAF Required) |
| 677 | OD350027/2025-2026:Supply and installation of 4MP BULLET IP with following specifications;1/2.8; 2 MP progressive scan imager, 1920 x 1080 resolution;3.6 mm Fixed lens, True day/night (IR-cut filter), Digital Wide Dynamic Range, Low-light performance down to 0.08 lux (color) or 0 lux with IR LEDs on Up to 98 ft (30 m) IR illumination, depending on scene reflectance, H.265 Smart Codec, Dual stream support, PoE (802.3af) or 12 VDC support, Plug-and-play compatible with Honeywell Performance Series Embedded NVRs;IP66 and IK10-rated rugged housing (Approved Make: Honeywell, Sony, AXIS) (MAF Required) |
| 678 | OD350046/2025-2026:Supply and installation of 5mp varifocal with following specifications <br>1/2.7" 5MP (2560×1920) progressive scan imager.8 ; 12 mm F1.4-F2.8, MFZ lens, Angle of view 88°~30° (H) ; 65°~23° (V) @ 5MP / 93°~32° (H); 51°~18° (V) @ 4MP, Main Stream: 5MP/4MP (1 ~ 25/30fps), Sub Stream: 800x600 (1 ~ 25/30fps), Third Stream: VGA (1 ~ 25/30fps), Wide Dynamic Range (WDR) up to 120 dB;Low light performance (0.035 lux in color mode), 50 m (165 ft) IR distance, depending on scene reflectance, H.265 Smart Codec video compression, Motion detection / Intrusion detection / People detection;(Approved Make: Sony, AXIS, Honeywell) (MAF Required) |
| 679 | OD350049/2025-2026:Supply and installation of 32 CH NVR with following specifications bull; High decoding capability for Ultra 4K HD viewing and recording • View 4/8/16 channels simultaneously with synchronized real-time playback on your monitor (depending on your model) • Up to 12 MP (4K) resolution live view, preview and playback • Up to 16 channels at 1080p H.265/H.264 decoding • De-warp fisheye All the cameras and NVR from same equipment manufacture |
| 680 | OD350028/2025-2026:"Supply of 8TB HDD For IP surveillance systemApproved Makes- WD/Thoshiba/Seagate" |
| 681 | OD350054/2025-2026:"Supply of IP-Camera Mounting boxApproved Makes- ISI PWD standard" |
| 682 | OD350020/2025-2026:"Supply of Camera side crimping Rj45 connectorApproved Makes- AMP/Molex/D-Link" |
| 683 | OD350007/2025-2026:Supply and installation of Conference Chairman unit Nominal Acoustic Input at the microphone 85dB SPL Frequency Response 400Hz to 10Khz Dimensions (without microphone) (H x W x D) 54x136x138mm, Length of the microphone from the base of the stem 488mm Mounting Tabletop Color Charcoal Priority button for chairman microphone, Microphone with flexible stem and light ring, Two headphone sockets |
| 684 | OD350023/2025-2026:Supply and installation of CONFERENCE CONTROLLER UNIT. Center Frequencies of Filters 250 Hz, 2 kHz and 8 kHz PA Output SNR More than -50 dB at rated output (unweighted filter) REC Out SNR More than -50 dB at rated output (unweighted filter) Dimensions 88 mm x 361 mm x 252 mm (H x W x D) Color Charcoal(RAL 10736) and Grey (for rear cover) THD at Rated Output Less than 1%, SNR More than -50 dB at rated output (unweighted filter ) |
| 685 | OD350035/2025-2026:Supply and installation of CONFERENCE DELEGATE UNIT Nominal Acoustic Input at the microphone 85dB SPL Frequency Response 400Hz to 10Khz Dimensions (without microphone) (H x W x D) 54x136x138mm, Playback , 44.1, 48 kHz, Length of the microphone from the base of the stem 488mm Mounting Tabletop, Color charcoal Operating temperature -5 degree C to +45 degree C, Storage temperature -40 degree C to +70 degree C |
| 686 | OD350042/2025-2026:Supply and installation of 120W USB Mixer Amplifier with standard machine cabinet design (1u), contraption, Exquisite craft, high-grade temperament. with mp3/TUNER/Bluetooth module, Digital screen displaying the current music from USB. With mp3/TUNER/Bluetooth remote control function. 1EMC input, 2 AUX input, 4MIC input, Channel priority: EMC > MIC1>MIC2, MIC3, AUX1, AUX2.Each channel has volume control function, master volume controls and bass/treble tone control. Has level indicator, overload and protection indicator. WithHigh temp, overload & short-circuit protection. 2 output modes : 100V, 70V (non- Bridged mode). High energy and energy saving design of power supply and efficient power amplifier |
| 687 | OD350040/2025-2026:Supply and installation of 30W SUPERB PROSOUND WALLMOUNT SPEAKER |
| 688 | OD350038/2025-2026:Supply and installation of Audio cable 15/M - CONFERENCE CONTROLLER UNIT to Conference Chairman unit. Approved Makes- Bose/Bosch/JBL/AUDIOTRAK |
| 689 | OD350052/2025-2026:Supply and installation of stand for screen |
| 690 | OD350029/2025-2026:Supply and Installation of Projector for V-Conference with full accessories Approved Makes- Benq/Epson/Sony |
| 691 | OD350045/2025-2026:Supply of software for vedio conference room |
| 692 | OD350015/2025-2026:Supply, Installation, Testing and Commissioning of 40 Inch LED Professional Display capable of working 24/7 with 3 Years of Warranty Preferred Make: Sony, Samsung, LG, Panasonic. |
| 693 | OD350039/2025-2026:Supply of programmable digital mixer with auto mixing and recording |
| 694 | OD350048/2025-2026:Supply of high SPL compact audio monitor |
| 695 | OD350012/2025-2026:Supply of bracket for the speaker |
| 696 | OD350050/2025-2026:Supply of goose neck microphone, logic functions, programmable switch |
| 697 | OD350003/2025-2026:Supply of dual channel hand held wireless system |
| 698 | OD350001/2025-2026:Supply of mixer and microphone mounting audio rack |
| 699 | OD350034/2025-2026:Supply and providing low noise signal cable |
| 700 | OD350053/2025-2026:Supply and installation of connector for cable and equipment |
| 701 | OD350036/2025-2026:"Supply of 4K HDMI Cable 15-20/mtr for PC to DisplayApproved Makes- WD/Thoshiba/Seagate" |
| 702 | 90.9.1.1:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.50x50mm Cable Management System with base and lid |
| 703 | 90.9.1.2:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree |
| 704 | 90.9.1.3:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat angle 90 Degree /Tee |
| 705 | 90.9.1.4:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree |
| 706 | 90.9.1.6:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat Cross |
| 707 | 90.9.1.7:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap |
| 708 | 90.9.1.9:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Joint cover |
| 709 | 90.9.1.10:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable retainer |
| 710 | 90.9.1.15:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External Tee |
| 711 | 90.9.1.16:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat tee |
| 712 | 90.9.1.17:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal tee |
| 713 | 90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid |
| 714 | 90.9.2.2:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable devider |
| 715 | 90.9.2.3:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree |
| 716 | 90.9.2.5:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree |
| 717 | 90.9.2.4:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat angle 90 degree |
| 718 | 90.9.2.7:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat cross |
| 719 | 90.9.2.8:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap |
| 720 | 90.9.2.10:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Joint cover |
| 721 | 90.9.2.11:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable retainer |
| 722 | 90.9.2.12:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.1 to 3 module mounting box |
| 723 | 90.9.2.13:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.4 to 5 module mounting box |
| 724 | 90.9.2.14:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.8 module mounting box |
| 725 | 90.9.2.19:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Reducer 100 x 50 to 50 x 50mm |
| 726 | 90.9.2.23:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External tee |
| 727 | 90.9.2.24:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat Tee |
| 728 | 90.9.2.25:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal Tee |
| 729 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 730 | 1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail