| 1 | Volume V - BILL OF QUANTITIES ESTABLISHMENT OF INSTITUTE FOR ORGAN AND TISSUE TRANSPLANT, CHEVAYUR, KOZHIKODE - CONSTRUCTION OF DERMATOLOGY HOSPITAL AND ITS ALLIED FACILITIES(Tender No. HITES/IDS/IOT-KZD-DRMTGY/25/26) Name of Bidder GENERAL ABSTRACT SL.No DESCRIPTION AMOUNT (Excl.GST) |
| 2 | CIVIL WORKS |
| 3 | PLUMBING WORKS |
| 4 | ELECTRICAL WORKS |
| 5 | ELV WORKS |
| 6 | FIRE FIGHTING |
| 7 | STP (50 KLD) |
| 8 | BUILDING SIGNAGES TOTAL AMOUNT (Excl GST) 0.0 |
| 9 | ESTABLISHMENT OF INSTITUTE FOR ORGAN AND TISSUE TRANSPLANT, CHEVAYUR, KOZHIKODE - CONSTRUCTION OF DERMATOLOGY HOSPITAL AND ITS ALLIED FACILITIES(Tender No. HITES/IDS/IOT-KZD-DRMTGY/25/26) Name of Bidder BOQ-CIVIL SL NO. DSR/ MORTH CODE DESCRIPTION UNIT QTY RATE IN FIGS. (Rs.) (EXCL.GST) RATE IN WORDS (Rs.) (EXCL.GST) AMOUNT (Rs.) (EXCL.GST) |
| 10 | 2.6.1 |
| 11 | 2.26.1 |
| 12 | 2.26.1x2 |
| 13 | 2.8.1 |
| 14 | 2.10.1.2 |
| 15 | 50.2.26.1 |
| 16 | 4.1.2 |
| 17 | 4.1.8 |
| 18 | 4.2.5 |
| 19 | 5.1.3 |
| 20 | 5.9.1 |
| 21 | 5.9.2 |
| 22 | 5.9.3 |
| 23 | 5.9.5 |
| 24 | 5.9.6 |
| 25 | 5.9.7 |
| 26 | 5.9.16.1 |
| 27 | 5.9.19 |
| 28 | 5.11.1 |
| 29 | 5.22.6 |
| 30 | 5.22A.6 |
| 31 | DSR ANALYSIS 5.33.1.2 |
| 32 | DSR ANALYSIS 5.33.2.2 |
| 33 | DSR ANALYSIS 5.33.1.1 |
| 34 | DSR ANALYSIS 5.33.2.1 |
| 35 | 50.6.2.1 |
| 36 | 50.6.1.4 |
| 37 | 50.6.1.5 |
| 38 | 50.6.1.6 |
| 39 | DSR ANALYSIS |
| 40 | DSR ANALYSIS |
| 41 | 7.1.1 |
| 42 | 8.2.2 |
| 43 | DSR ANALYSIS |
| 44 | 8.3.2 |
| 45 | DSR ANALYSIS |
| 46 | DSR ANALYSIS |
| 47 | DSR ANALYSIS |
| 48 | 11.3.1 |
| 49 | 11.6.1 |
| 50 | 11.20.3 |
| 51 | 11.41.2 |
| 52 | 11.46.2 |
| 53 | 11.41A.3.1 |
| 54 | DSR ANALYSIS |
| 55 | DSR ANALYSIS |
| 56 | 11.56.1 |
| 57 | 12.52.3 12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit. sqm 232.88 29 0.0 |
| 58 | 12.52.1 GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending sqm 1235.61 29 0.0 |
| 59 | 12.59.1 Calcium Silicate Board to ceiling section and perimeter channels with the help of day wall screws of size 3.5x25mm at 230mm c/c, including jointing finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes, finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufactures specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitable fixed, all complete as per drawings, specification and direction of the Engineer in charge but excluding the cost of painting with 8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process. sqm 782.57 29 0.0 |
| 60 | 13.1.1 |
| 61 | 13.4.1 |
| 62 | 13.16.1 |
| 63 | 13.33.1 |
| 64 | 13.22 |
| 65 | DSR ANALYSIS |
| 66 | 13.43.1 |
| 67 | 13.45.1 |
| 68 | 13.47.1 |
| 69 | 13.60.1 |
| 70 | 13.61.1 |
| 71 | 13.9.1 |
| 72 | 13.21 |
| 73 | DSR ANALYSIS |
| 74 | 10.6.1 |
| 75 | 10.16.1 |
| 76 | 10.18 |
| 77 | 10.25.1 |
| 78 | 10.25.2 |
| 79 | 10.26.3 |
| 80 | DSR ANALYSIS |
| 81 | 10.28 |
| 82 | 21.1.1.2 |
| 83 | 21.1.2.2 |
| 84 | 21.2.2 |
| 85 | DSR ANALYSIS |
| 86 | DSR ANALYSIS |
| 87 | 21.3.3 |
| 88 | DSR ANALYSIS |
| 89 | DSR ANALYSIS |
| 90 | 9.1.1 |
| 91 | 9.5.1.1 |
| 92 | 9.7.1 |
| 93 | 9.71.2 |
| 94 | 9.21.1 |
| 95 | 9.22.1 |
| 96 | 9.24.1 |
| 97 | 9.74.1 |
| 98 | 9.48.2 |
| 99 | 9.97.2 |
| 100 | 21.13 |
| 101 | 9.100.1 |
| 102 | 9.101.2 |
| 103 | 21.4.1 |
| 104 | 9.121 |
| 105 | 9.122.2 |
| 106 | 50.9.15.2 |
| 107 | 9.147A.1 |
| 108 | 9.147A.2 |
| 109 | 9.147A.3 |
| 110 | 9.147A.4 |
| 111 | 9.147A.5 |
| 112 | DSR ANALYSIS |
| 113 | DSR ANALYSIS |
| 114 | 21.11.3 |
| 115 | 21.15.2 |
| 116 | 22.4.1 |
| 117 | DSR ANALYSIS |
| 118 | MR Door leaf should be minimum 60mm thick fully flush double skindoor. Door leaf must be manufactured from 1.2mm(18 gauge) thick galvanised steel sheet. The infill material shall be honeycomb craft paper insulation. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For double leaf doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. The shutters shall be mounted to the frame with SS 304 grade ball bearing type hinges of size 100x89x3 mm along with all suitable hardware (Triple point panic bar, SS ball bearing hinges, door closer, panic Trim, 6mm thick 300X400MM vision panel fire clear glass, etc complete). Vision lite glass size 300mm x 400mm (max area upto 0.12sqm) wherever applicable should be provided with single layered clear fire rated glass panes as per guidelines laid down under IS 3614 : 2021 vide clause no. 7.2.7 table no. 2 with a clipon arrangement. The glass will be provided with fire rated ceramic tape of suitable size alround on either face. Every Glass pane must carry a permanent marking of approved make. Door must be tested with vision panel- 6mm thick pyroswiss glass of approved make.Single leaf door. Size : 1000x2250mm Each 7.0 29 0.0 |
| 119 | MR Door leaf should be minimum 60mm thick fully flush double skin door. Door leaf must be manufactured from 1.2mm(18 gauge) thick galvanised steel sheet. The infill material shall be honeycomb craft paper insulation. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For double leaf doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. The shutters shall be mounted to the frame with SS 304 grade ball bearing type hinges of size 100x89x3 mm along with all suitable hardware (Triple point panic bar, SS ball bearing hinges, door closer, panic Trim, 6mm thick 300X400MM vision panel fire clear glass, etc complete). Vision lite glass size 300mm x 400mm (max area upto 0.12sqm) wherever applicable should be provided with single layered clear fire rated glass panes as per guidelines laid down under IS 3614 : 2021 vide clause no. 7.2.7 table no. 2 with a clipon arrangement. The glass will be provided with fire rated ceramic tape of suitable size alround on either face. Every Glass pane must carry a permanent marking of approved make. Door must be tested with vision panel- 6mm thick pyroswiss glass of approved make. .Single leaf door. Size : 1200x2250mm Each 9.0 29 0.0 |
| 120 | MR Door shutter: The double skin single leaf door shutter shall be consisting of minimum 46 mm thick and having box like structure, slots cut and holes punched, for fixing of hardwares with stiffeners as per IS: 16074 including Resin bonded honey comb paper core infill material of density 5 kg/cum. The door shutter shall be mounted on the frame with SS 304 grade ball bearing butt hinges as per EN 1935: 2002 or butt hinges as per IS 12817 both, of minimum size 100x75x3 mm @ minimum 4 numbers up to 2100 mm/2400 mm height or as per test evidence,which ever is more, fixed with M6 25 screws. All doors shall be factory prepared for receiving appropriate hardware and provided with necessary reinforcement for hardware accessories. Hardware Accessories Fire doorset assembly shall be provided with one number fire rated SS 304 shaft mortise dead lock, one number 50-80 mm Back Set with minimum 20 mm Square forend with allen key including SS304 dead strike plate conforming to IS: 16015:2022/EN 12209, one number recessed flush pull handle (SS304) of minimum size 40 mm x 120 mm, as approved by Engineer-in-Charge. Finishing: Both frame and door shutters shall be factory finished with polyester powder coating of minimum 50 microns thick and shall have passed salt spray test as per IS:13871 of approved colour and shade all complete as per manufacturer's specifications and as per direction of the Engineer-in-charge. Installation: The hollow space in the door frame shall be filled / injected with fire rated self extinguishing type polyurethane foam (PUF) after installation at site of work. The rate shall be inclusive of complete fire rated door assembly, supply and installation by the approved manufacturer. Single leaf uninsulated metal fire rated door and frame of FD 120UD with 120minits integrity only as per IS 3614:2021-for non egress application like area shafts etc sqm 21.6 29 0.0 |
| 121 | 22.22 |
| 122 | 22.23.2 |
| 123 | 19.16 |
| 124 | DSR ANALYSIS |
| 125 | DSR ANALYSIS |
| 126 | DSR ANALYSIS |
| 127 | 15.18 |
| 128 | 15.7.4 |
| 129 | 15.9.2 |
| 130 | DSR ANALYSIS |
| 131 | 16.68 |
| 132 | 16.69 |
| 133 | 16.91.2 |
| 134 | MORTH 4.1.A.1 |
| 135 | MORTH 4.12 |
| 136 | MORTH 5.3.1.a |
| 137 | MORTH 5.6.1.a |
| 138 | MORTH 5.1.a |
| 139 | MORTH 5.2.b TOTAL AMOUNT (EXCL. GST) 0.0 |
| 140 | ESTABLISHMENT OF INSTITUTE FOR ORGAN AND TISSUE TRANSPLANT, CHEVAYUR, KOZHIKODE - CONSTRUCTION OF DERMATOLOGY HOSPITAL AND ITS ALLIED FACILITIES(Tender No. HITES/IDS/IOT-KZD-DRMTGY/25/26) Name of Bidder BOQ-PLUMBING ITEM NO DSR CODE DETAILS OF ITEM UNIT Quantity RATE IN FIGS. (Rs.) (EXCL.GST) RATE IN WORDS (Rs.) (EXCL.GST) AMOUNT (Rs.) (EXCL.GST) PLUMBING SANITORY FIXRTURES AND FITTINGS |
| 141 | 17.3.2 |
| 142 | 8.10.2 |
| 143 | 17.10.1.1 |
| 144 | 17.69.2 |
| 145 | 17.31 |
| 146 | 17.72 |
| 147 | 17.71 |
| 148 | 18.21.2.1 |
| 149 | 18.53.1 |
| 150 | 18.65 |
| 151 | 50.17.1.2 |
| 152 | 17.32.4 |
| 153 | 18.8.1 |
| 154 | 18.8.2 |
| 155 | 18.8.3 |
| 156 | 18.8.4 |
| 157 | 18.17.1 |
| 158 | 18.17.1A |
| 159 | 18.17.2 |
| 160 | 18.17.3 |
| 161 | 18.17.4 |
| 162 | 12.44 |
| 163 | 18.48 |
| 164 | 17.70.1 |
| 165 | 19.6.3 |
| 166 | 19.7.1.1 |
| 167 | 19.8.1.1 |
| 168 | 19.16 |
| 169 | 2.10.1.2 |
| 170 | 19.8.2.1 |
| 171 | 19.7.2.1 |
| 172 | 19.32.1 |
| 173 | MR TOTAL AMOUNT (EXCL. GST) 0.0 |
| 174 | ESTABLISHMENT OF INSTITUTE FOR ORGAN AND TISSUE TRANSPLANT, CHEVAYUR, KOZHIKODE - CONSTRUCTION OF DERMATOLOGY HOSPITAL AND ITS ALLIED FACILITIES(Tender No. HITES/IDS/IOT-KZD-DRMTGY/25/26) Name of Bidder BOQ-ELECTRICAL Sl. No DSR No. DESCRIPTION UNIT QTY RATE IN FIGS. (Rs.) (EXCL.GST) RATE IN WORDS (Rs.) (EXCL.GST) AMOUNT (Rs.) (EXCL.GST) 1. WIRING |
| 175 | 1.3.1 LMR 2 x 1.5 sq.mm + 1x1.5 sq.mm earth wire m 4185.0 29 0.0 1.3.2 LMR 2 x 2.5 sq.mm + 1x 2.5 sq.mm earth wire m 8370.0 29 0.0 1.3.3 LMR 2 x 4 sq.mm +1x 4 sq.mm earth wire m 1395.0 29 0.0 1.3.4 LMR 2 X 6 sqmm + 1 x 6 sqmm earth wire m 100.0 29 0.0 |
| 176 | 1.4.1 1.21.1 20 mm m 50.0 29 0.0 1.4.2 1.21.2 25 mm m 100.0 29 0.0 1.4.3 1.21.3 32 mm m 100.0 29 0.0 1.4.4 1.21.4 40 mm m 50.0 29 0.0 |
| 177 | 1.50.1 |
| 178 | 1.55.3 |
| 179 | 15.4.3 3 output (1 output per phase) and suitable for three phase supply 2. MCCB, MCB & DBs |
| 180 | 2.3.3 2.3.3 12 way double door each 5.0 29 0.0 |
| 181 | 2.2.1 2.4.1 4 way Double Door each 14.0 29 0.0 2.2.2 2.4.2 6 way Double Door each 19.0 29 0.0 2.2.3 2.4.3 8 way Double Door each 2.0 29 0.0 |
| 182 | 2.3.1 2.5.1 4 way Double door each 6.0 29 0.0 |
| 183 | 2.4.1 2.10.1 Single pole each 370.0 29 0.0 2.4.2 2.10.3 Double pole each 10.0 29 0.0 2.4.3 2.10.4 Triple pole each 50.0 29 0.0 2.4.4 2.10.5 Triple pole and neutral each 20.0 29 0.0 |
| 184 | 2.6.1 2.12.1 40 amps each 5.0 29 0.0 |
| 185 | 2.7.1 2.13.1 40 amps each 22.0 29 0.0 2.7.2 2.13.2 63 amps each 11.0 29 0.0 |
| 186 | 2.8.1 2.14.1 25 amps each 5.0 29 0.0 |
| 187 | 2.9.1 2.15.1 25 amps each 4.0 29 0.0 2.9.2 2.15.2 40 amps each 15.0 29 0.0 2.9.3 2.15.3 63 amps each 15.0 29 0.0 |
| 188 | 2.17 2.12.1 2.24.1 Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 4 way, Double door TPN MCBDB each 14.0 29 0.0 2.12.2 2.24.2 Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door TPN MCBDB each 19.0 29 0.0 2.12.3 2.24.3 Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 8 way, Double door TPN MCBDB each 2.0 29 0.0 2.12.4 90.11.1.15 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) each 4.0 29 0.0 2.12.5 90.11.1.18 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) each 2.0 29 0.0 2.12.6 90.11.1.19 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) each 2.0 29 0.0 2.12.7 90.11.1.20 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) each 3.0 29 0.0 3. CABLE TRAY |
| 189 | 4.6.2 |
| 190 | 4.6.4 |
| 191 | 4.6.6 |
| 192 | 4.6.7 4. EARTHING |
| 193 | 5.19 5. MV CABLE LAYING |
| 194 | 5.1.1 7.1.1 Upto 35 sq. mm m 1650.0 29 0.0 |
| 195 | 5.2.1 7.5.2 Above 35 sq. mm and upto 95 sq. mm m 720.0 29 0.0 5.2.2 7.5.4 Above 185 sq. mm and upto 400 sq. mm m 420.0 29 0.0 |
| 196 | 7.6 5.3.1 7.6.4 Above 185 sq. mm and upto 400 sq. mm m 330.0 29 0.0 |
| 197 | 5.4.1 7.7.1 Upto 35 sq. mm (clamped with 1mm thick saddle) m 985.0 29 0.0 5.4.2 7.7.2 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) m 175.0 29 0.0 5.4.3 7.7.3 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) m 25.0 29 0.0 5.4.4 7.7.4 Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) m 50.0 29 0.0 |
| 198 | 5.5.1 7.8.1 Upto 35 sq. mm (clamped with 1mm thick saddle) m 2130.0 29 0.0 5.5.2 7.8.2 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) m 277.0 29 0.0 5.5.3 7.8.3 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) m 65.0 29 0.0 5.5.4 7.8.4 Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) m 45.0 29 0.0 |
| 199 | 7.9 6. MV CABLE JOINTING & END TERMINATION |
| 200 | 9.1.32 |
| 201 | 9.1.33 |
| 202 | 9.1.34 |
| 203 | 9.1.22 |
| 204 | 9.1.23 |
| 205 | 9.1.30 7. HT CABLE JOINTING & END TERMINATION |
| 206 | 10.4.4 300 sq. mm each 4.0 29 0.0 8. MISCELLANEOUS CIVIL ITEMS |
| 207 | 8.1.1 14.14.1 100 mm dia m 50.0 29 0.0 8.1.2 14.14.2 150 mm dia m 140.0 29 0.0 8.1.3 14.14.4 300 mm dia m 250.0 29 0.0 8.1.4 14.16.3 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part Il complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required 120mm dia(OD-120mm &ID-103mm nominal) m 50.0 29 0.0 9. SOLAR |
| 208 | LMR 10. HT PANEL, HT CABLE, TRANSFORMER AND DG |
| 209 | LMR 11. LT Panels |
| 210 | LMR 500/5A 15VA class 1 resin cast CT - 2 set200/5A 15VA class 1 resin cast CT for connection to APFC panel including necessary size connecting cable - 1 setOutgoing.320A FP 25kA MCCB with microprocessor release with adjustable OL, SC protection and EF protection - 1no.200A FP 25kA MCCB with thermal magnetic release with adjustable OL, SC protection - 3no.160A FP 25kA MCCB with thermal magnetic release with adjustable OL, SC protection - 1 no.100A FP 25kA MCCB with thermal magnetic release with adjustable OL, SC protection - 6 no.250A FP 25kA isolator with front operated handle - 1no.12 no 3 phase Digital Multi function meter to read V, A, F, kW, kWh with Acc class 1 including respective feeder rating CT on the incoming and outgoing feeders |
| 211 | LMR 12. UPS |
| 212 | LMR 13. LT CABLES Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. |
| 213 | LMR 14. LIGHT FITTINGS & FANS |
| 214 | LMR 15. External Lighting |
| 215 | 90.15.3.1 |
| 216 | 90.15.3.2 |
| 217 | 90.15.4.2 16. Lightning Protection System |
| 218 | LMR 17. MISCELLANEOUS |
| 219 | LMR 18. RMU & HT CABLE LAYING |
| 220 | LMR TOTAL AMOUNT (EXCL. GST) 0.0 |
| 221 | ESTABLISHMENT OF INSTITUTE FOR ORGAN AND TISSUE TRANSPLANT, CHEVAYUR, KOZHIKODE - CONSTRUCTION OF DERMATOLOGY HOSPITAL AND ITS ALLIED FACILITIES (Tender No. HITES/IDS/IOT-KZD-DRMTGY/25/26) Name of Bidder BOQ-ELV Sl. No DSR No. DESCRIPTION UNIT QTY RATE IN FIGS. (Rs.) (EXCL.GST) RATE IN WORDS (Rs.) (EXCL.GST) AMOUNT (Rs.) (EXCL.GST) 1. FIRE ALARM SYSTEM |
| 222 | 4.6.2 |
| 223 | 14.16.1 |
| 224 | LMR 2. PUBLIC ADDRESS SYSTEM |
| 225 | 14.16.1 3. CCTV System |
| 226 | 1.21.2 |
| 227 | 1.53.1 |
| 228 | 4.6.2 |
| 229 | 14.16.12 |
| 230 | LMR 4. DATA SYSTEM |
| 231 | 1.21.2 |
| 232 | 1.21.3 |
| 233 | 1.27.1 |
| 234 | 1.53.1 |
| 235 | 1.53.2 |
| 236 | 4.6.2 |
| 237 | LMR 5. TELEPHONE SYSTEM |
| 238 | 1.18.2 |
| 239 | 1.21.2 |
| 240 | 1.24.6 |
| 241 | 1.27.1 |
| 242 | 4.6.2 |
| 243 | 14.16.1 |
| 244 | LMR 6.TV SYSTEM |
| 245 | 1.21.2 |
| 246 | 1.21.3 |
| 247 | 1.24.7 |
| 248 | 1.27.1 |
| 249 | LMR TOTAL AMOUNT (EXCL. GST) 0.0 |
| 250 | ESTABLISHMENT OF INSTITUTE FOR ORGAN AND TISSUE TRANSPLANT, CHEVAYUR, KOZHIKODE - CONSTRUCTION OF DERMATOLOGY HOSPITAL AND ITS ALLIED FACILITIES (Tender No. HITES/IDS/IOT-KZD-DRMTGY/25/26) Name of Bidder BOQ-FIRE FIGHTING WORKS Item No. Item Code Item Description Qty Unit RATE IN FIGS. (Rs.) (EXCL.GST) RATE IN WORDS (Rs.) (EXCL.GST) AMOUNT (Rs.) (EXCL.GST) |
| 251 | 18.1.9 |
| 252 | 18.2.9 |
| 253 | 18.3.3 |
| 254 | 18.4.2 |
| 255 | 18.5.1 |
| 256 | 18.6.2 |
| 257 | 18.7.1 |
| 258 | 18.7.2 |
| 259 | 18.7.3 |
| 260 | 18.7.4 |
| 261 | 18.7.5 |
| 262 | 18.7.6 |
| 263 | 18.7.7 |
| 264 | 18.7.8 |
| 265 | 18.9.2 |
| 266 | 18.10.2 |
| 267 | 18.11.4 |
| 268 | 18.11.5 |
| 269 | 18.11.6 |
| 270 | 18.12.7 |
| 271 | 18.14.4 |
| 272 | 18.14.5 |
| 273 | 18.14.7 |
| 274 | 18.15.1 |
| 275 | 18.15.3 |
| 276 | 18.16.2 |
| 277 | 18.17.1 |
| 278 | 18.18.2 |
| 279 | 18.19.2 |
| 280 | 18.21.1 |
| 281 | 18.21.2 |
| 282 | 18.22 |
| 283 | 18.23.1 |
| 284 | 18.24.3 |
| 285 | 18.25.2 |
| 286 | 18.29 |
| 287 | MR TOTAL AMOUNT (EXCL. GST) 0.0 |
| 288 | ESTABLISHMENT OF INSTITUTE FOR ORGAN AND TISSUE TRANSPLANT, CHEVAYUR, KOZHIKODE - CONSTRUCTION OF DERMATOLOGY HOSPITAL AND ITS ALLIED FACILITIES (Tender No. HITES/IDS/IOT-KZD-DRMTGY/25/26) Name of Bidder BOQ-HVAC WORKS Item No. Item Code Item Description Qty Unit RATE IN FIGS. (Rs.) (EXCL.GST) RATE IN WORDS (Rs.) (EXCL.GST) AMOUNT (Rs.) (EXCL.GST) |
| 289 | MR a 36 HP Nos 1.0 29 0.0 |
| 290 | 16.12.1 a 16.12.1.1 24G sq mts 150.0 29 0.0 b 16.12.1.2 22G sq mts 35.0 29 0.0 |
| 291 | 16.12.2 a 16.12.2.1 24G sq mts 30.0 29 0.0 b 16.12.2.2 22G sq mts 15.0 29 0.0 |
| 292 | 16.13 |
| 293 | 16.17 |
| 294 | 16.15 |
| 295 | MR a 150 mm Dia Rmts 10.0 29 0.0 b 200 mm Dia Rmts 10.0 29 0.0 c 250 mm Dia Rmts 20.0 29 0.0 |
| 296 | 16.20.1 16.20.2 Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Actuator Nos 5.0 29 0.0 |
| 297 | MR a 200 CFM Nos 2.0 29 0.0 b 150 CFM Nos 3.0 29 0.0 c 100 CFM Nos 1.0 29 0.0 d 300 CFM Nos 2.0 29 0.0 TOTAL AMOUNT (EXCL. GST) 0.0 |
| 298 | ESTABLISHMENT OF INSTITUTE FOR ORGAN AND TISSUE TRANSPLANT, CHEVAYUR, KOZHIKODE - CONSTRUCTION OF DERMATOLOGY HOSPITAL AND ITS ALLIED FACILITIES (Tender No. HITES/IDS/IOT-KZD-DRMTGY/25/26) Name of Bidder BOQ-LIFT WORKS Item No. Item Code Item Description Unit Qty RATE IN FIGS. (Rs.) (EXCL.GST) RATE IN WORDS (Rs.) (EXCL.GST) AMOUNT (Rs.) (EXCL.GST) |
| 299 | MR TOTAL AMOUNT (EXCL. GST) 0.0 |
| 300 | ESTABLISHMENT OF INSTITUTE FOR ORGAN AND TISSUE TRANSPLANT, CHEVAYUR, KOZHIKODE - CONSTRUCTION OF DERMATOLOGY HOSPITAL AND ITS ALLIED FACILITIES (Tender No. HITES/IDS/IOT-KZD-DRMTGY/25/26) Name of Bidder BOQ-SIGNAGE ITEM NO DSR CODE DESCRIPTION UNIT QTY RATE IN FIGS. (Rs.) (EXCL.GST) RATE IN WORDS (Rs.) (EXCL.GST) AMOUNT (Rs.) (EXCL.GST) |
| 301 | DSR ANALYSIS |
| 302 | DSR ANALYSIS |
| 303 | DSR ANALYSIS |
| 304 | DSR ANALYSIS |
| 305 | DSR ANALYSIS |
| 306 | DSR ANALYSIS |
| 307 | DSR ANALYSIS |
| 308 | DSR ANALYSIS |
| 309 | DSR ANALYSIS TOTAL AMOUNT (EXCL. GST) 0.0 |
| 310 | ESTABLISHMENT OF INSTITUTE FOR ORGAN AND TISSUE TRANSPLANT, CHEVAYUR, KOZHIKODE - CONSTRUCTION OF DERMATOLOGY HOSPITAL AND ITS ALLIED FACILITIES (Tender No. HITES/IDS/IOT-KZD-DRMTGY/25/26) Name of Bidder BOQ-MGPS SN. Item Description Unit Quantity RATE IN FIGS. (Rs.) (EXCL.GST) RATE IN WORDS (Rs.) (EXCL.GST) AMOUNT (Rs.) (EXCL.GST) |
| 311 | MR Solid drawn, seamless, deoxidised, non- arsenical, half hard, tempered and degreased copper pipes as per tender technical specifications 0.0 |
| 312 | LINE ISOLATION VALVES |
| 313 | OT Pendants (Anesthetist & Surgeon) |
| 314 | MR TOTAL AMOUNT (EXCL. GST) 0.0 |
| 315 | ESTABLISHMENT OF INSTITUTE FOR ORGAN AND TISSUE TRANSPLANT, CHEVAYUR, KOZHIKODE - CONSTRUCTION OF DERMATOLOGY HOSPITAL AND ITS ALLIED FACILITIES (Tender No. HITES/IDS/IOT-KZD-DRMTGY/25/26) Name of Bidder BOQ-STP Item No. Item Code Item Description Unit Qty RATE IN FIGS. (Rs.) (EXCL.GST) RATE IN WORDS (Rs.) (EXCL.GST) AMOUNT (Rs.) (EXCL.GST) |
| 316 | MR TOTAL AMOUNT (EXCL. GST) 0.0 |
| 317 | Financial Bid (PART -B)-O&M and CAMC For STP & ETP ESTABLISHMENT OF INSTITUTE FOR ORGAN AND TISSUE TRANSPLANT, CHEVAYUR, KOZHIKODE - CONSTRUCTION OF DERMATOLOGY HOSPITAL AND ITS ALLIED FACILITIES (Tender No. HITES/IDS/IOT-KZD-DRMTGY/25/26) Name of the Bidder: PART-B1 - O&M S.No. Project Component Cost in INR (Excl. GST) |
| 318 | Operation & Maintenance of entire system for a minimum period of 9 Years including consumables and manpower after completion of 12 months of operation. |
| 319 | 1st year |
| 320 | 2nd year |
| 321 | 3rd Year |
| 322 | 4th Year |
| 323 | 5th Year |
| 324 | 6th Year |
| 325 | 7th Year |
| 326 | 8th Year |
| 327 | 9th Year Total (PART-B1) (excl. GST) 0.0 |
| 328 | PART-B2 - CAMC S.No. Project Component Cost in INR (Excl. GST) |
| 329 | CAMC for 7 years after completion of DLP |
| 330 | 1st year |
| 331 | 2nd year |
| 332 | 3rd Year |
| 333 | 4th Year |
| 334 | 5th Year |
| 335 | 6th Year |
| 336 | 7th Year Total (PART-B2) (excl. GST) 0.0 |
| 337 | Total for Part B (PART-B1+PART-B2) (Excl. GST) 0.0 The rates quoted at Part B will be not be considered for determining L1 Financial Bid (PART -B) For MGPS ESTABLISHMENT OF INSTITUTE FOR ORGAN AND TISSUE TRANSPLANT, CHEVAYUR, KOZHIKODE - CONSTRUCTION OF DERMATOLOGY HOSPITAL AND ITS ALLIED FACILITIES (Tender No. HITES/IDS/IOT-KZD-DRMTGY/25/26) Name of Bidder: PART-B - O&M For MGPS |
| 338 | Providing Comprehensive Maintainenace Contract for Medical Gas Pipeline System (MGPS) on successful completion of Warranty |
| 339 | 1st year |
| 340 | 2nd year |
| 341 | 3rd Year |
| 342 | 4th year |
| 343 | 5th year Total (PART-B) (excl. GST) 0.0 The rates quoted at Part B will be not be considered for determining L1 |