| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | All kinds of soil. |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 4 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 5 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 6 | Clearing grass and removal of the rubbish up to a distance of 50 m rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 7 | Cutting and Felling branches of one tree (damaging the compound wall / cycle / scooter shed ) of the any girth including cutting of trunks and branches, removing and stacking of serviceable material and disposal of unserviceable material, complete as per direction of engineer in charge. |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 9 | 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 10 | 1:5:10 (1 cement : 5 fine sand derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 11 | Centering and shuttering including strutting, propping etc. and emoval of form work for : |
| 12 | Foundations, footings, bases for columns |
| 13 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 14 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 16 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 17 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. |
| 18 | Thermo-Mechanically Treated bars. |
| 19 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in foundation and plinth in: |
| 20 | Cement mortar 1:6 ( 1cement :6 Corse sand) |
| 21 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 22 | Cement mortar 1:6 ( 1cement :6 Corse sand) |
| 23 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). |
| 24 | Second class teak wood |
| 25 | Sal wood |
| 26 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. |
| 27 | Planks of IInd class Bija wood |
| 28 | 30 mm thick shutters |
| 29 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : |
| 30 | IInd class Bija wood |
| 31 | Providing and fixing glazed shutter for doors,windows,and clerestory windows using 4mm thick floating glass panes including black enamelled ISI marked M.S. butt hinges with necessary screws . |
| 32 | 30 mm thick ,Secnd class bija wood. |
| 33 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand: 6 graded stone aggregate 20mm nominal size). |
| 34 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : |
| 35 | 300x16 mm |
| 36 | Providing and fixing ISI marked oxidised M.S. Tower bolt black finished ,( barrel type ) with necessary screws etc. complete. |
| 37 | 250x10mm |
| 38 | 150x10mm |
| 39 | Providing and fixing ISI marked oxidised M.S.handles conforming to IS:4992 with necessary screws etc. complete. |
| 40 | 100mm |
| 41 | Providing and fixing glazed aluminium windows / ventilator with two track 1 mm thick aluminium sections of Anodised aluminium (anodised transparentor dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 5) with glazing of 4 mm thick glass panes and required locking arrangement, accessories in window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc., filling gaps with silicon sealant complete as per the directions of engineer-in-charge . |
| 42 | Structural steel work riveted, bolted or welded in built up sections, trussesand framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 43 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. |
| 44 | Using flats 30x6mm for diagonal braces and central cross piece |
| 45 | Welding by gas or electric plant including transportation of plant at site etc. complete. |
| 46 | Providing and Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metalsash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, including priming coat of approved steel primer, and cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). |
| 47 | Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 48 | Providing and fixing special quality 100 mm locks with six levers of approved quality including necessary screws welding with steel doors etc. complete. |
| 49 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes. |
| 50 | 110 mm diameter |
| 51 | 75 mm diameter |
| 52 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. |
| 53 | Coupler |
| 54 | 110 mm |
| 55 | Single tee with door |
| 56 | 75x75x75 mm |
| 57 | 110x110x110mm |
| 58 | Bend 87.5° |
| 59 | 75 mm bend |
| 60 | 110 mm bend |
| 61 | Shoe(Plain) |
| 62 | 110 mm |
| 63 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 64 | 75 mm |
| 65 | 110 mm |
| 66 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, xcluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 67 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 68 | Ridges plain (500 - 600mm) |
| 69 | 12 mm cement plaster of mix : |
| 70 | 1:6 ( 1 Cement :6 Coarse sand) |
| 71 | 15 mm cement plaster of mix: |
| 72 | 1:6 ( 1 Cement :6 Coarse sand) |
| 73 | 6 mm cement plaster of mix : |
| 74 | 1:3 (1 cement : 3 fine sand) |
| 75 | Neat cement punning |
| 76 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 77 | New work (Two or more coats applied @ 1.67 litre/ 10sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 78 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters20 mm in patches of area 2.5 sq meters and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to dumping ground within 50 metres lead : |
| 79 | With cement mortar 1 : 4 (1 cement :4 coarse sand). |
| 80 | Repairs to RCC chajjas ,Ceiling fines ,facias etc. by ;- (a) Demolishing RCC work including stcking of steel bars and disposal of unserviceable material. (b) Applying cement slurry and necessary chemical additive required for bonding old and new concrete and for reinforcement. (c) providing of plaster of thickness 12 mm to 20 mm with Cement concrete ( 1 cement :1 Coarse sand :2 Stone aggregate 6 mm and dowen size ) (d) providing cement plaster of mix 1:3 ( 1 Cement : fine sand ) (e) Providing and fixing scaffolding upto 3.00 metre height and disposal of rubbish to dumping ground within 50 metres lead :( Rate includes the cost of material and labours required for above oparation . (Note : scaffolding required more then 3.00 metre height will be paid for separately in respective item). |
| 81 | Renewing glass panes and refixing existing wooden fillets / new glass putty : |
| 82 | Float glass panes of thickness 4 mm. |
| 83 | White washing with lime to give an even shade: |
| 84 | Old work (two or more coats). |
| 85 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and of required shade and colour complete to give and even shade. |
| 86 | Old work (One or more coats). |
| 87 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 88 | Old work (Two or more coat applied @ 1.67 ltr/10 sqm ) |
| 89 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 90 | One or more coats on old work. |
| 91 | Disposal of materials like excavated earth, moorum, excavated rocks, building rubbish, malba, sludge etc. by mechanical transport to the dumping ground including loading, unloading, stacking, spreading and levelling etc. as per requirement within municiple limits complete as per direction of Engineer in charge. |
| 92 | Cleaning of over head / underground water tanks including removal of scales, silt, rags etc. and disinfecting with bleaching powder as per standard quality and as per direction of Engineer in charge complete. |
| 93 | Any Capacity water tank. |
| 94 | Cleaning of manhole and removing all types of rubbish and sludge with propper rodding to the next manhole and cleaning the sewer line between two manholes and disposal of all types of rubbish and sludge as required and as directed by the Engineer in charge. |
| 95 | Removal of choakage from C.I. / HDPE pipes and fittings SW pipes etc. upto gully traps cleaning and disposal of all types of rubbish and sludge as directed by Engineer in charge. |
| 96 | Cleaning of terrace including cleaning of outlet for rain water, chhajja and disposal of rubbish, malba out of compound etc. complete as per direction of Engineer in charge. |
| 97 | Terrace of T. E. Building / other office Building. |
| 98 | Terrace of Staff quarter T-I to T-III |
| 99 | Providing skilled labour for trade like plumbing / sewer / masonry / carpentry / bandhani / works which are not covered and measurable in items of DSR 2021 [Note: contractor shall provide skilled labour of respective trade alonghwith necessary tools and plants]. |
| 100 | Providing casual labour, coolie / beldar for day to day maintainance work which are not covered and measurable in items of DSR 2021 |
| 101 | Repairs to wooden / aluminium doors, windows etc. including dismantling and refixing the same with screws, hinges, or by welding if required etc. doing all the operation complete as per direction of Engineer in charge. [Note: New Section, new hinges, fittings etc. if required will be paid for separately]. |
| 102 | Dismantling and refixing in proper position double leaf M.S. main gate of area 15 square metre or more including transportation of welding machine, gas cutter to site and cutting the gate from holdfast from both the gate columns including making proper arrangement of safety and scaffolding and after cutting it wil be again welded in position for refixing the gate after raising the height of gate as per direction of Engineer in charge complete. [Note : Rate includes transportation of welding machine, cutter, safety equipments, scaffolding, and welding charges, only additional M.S. member wil be paid for separately if required] |
| 103 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40mm dia. M.S. tube 1.5m centre to centre horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. |
| 104 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in- charge. |
| 105 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 106 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 107 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineerin- charge. |
| 108 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 109 | In cement mortar |
| 110 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 111 | Of area 3 sq. metres and below |
| 112 | Supplying at site angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. Complete. |
| 113 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including s trengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction ofEngineer-in-charge. |
| 114 | Made of G.I. wire of dia 4 mm |
| 115 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 116 | Flexible pipe |
| 117 | 32 mm dia |
| 118 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 119 | White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 120 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 121 | 10 litre capacity - White |
| 122 | Providing and fixing white vitreous china water closet squatting pan (Indian type) including providing and fixing PVC P or S trap , connecting with fluhing cistern etc. complete. |
| 123 | Orissa pattern W.C. pan of size 580x440 mm |
| 124 | Providing and fixing P.V.C. trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors of 100 mm inlet and 100 mm outlet |
| 125 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall |
| 126 | 15 mm nominal outer dia. Pipes. |
| 127 | 25 mm nominal outer dia. Pipes. |
| 128 | 40 mm nominal outer dia. Pipes. |
| 129 | Providing and fixing unplasticised PVC connection pipe with brass unions : |
| 130 | 45 cm length : |
| 131 | 15 mm nominal bore. |
| 132 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 133 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : |
| 134 | 15 mm dia nominal bore. |
| 135 | 25 mm dia nominal bore. |
| 136 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS : 8931 : |
| 137 | 15 mm nominal bore. |
| 138 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 139 | 15 mm nominal bore. |
| 140 | Providing and fixing C.P. brass Pillar cock 15 mm nominal bore of standard design and of approved make conforming to IS specification. |
| 141 | Credit for brass 15 mm nominal bore stop cock / bib cock / pillar cock / gate valve. |
| 142 | Providing and fixing HDPE tank cover with suitable locking arrangement complete as per direction of Engineer in charge. |
| 143 | Providing and fixing brass half turn gate valve with M.S. handle of ZOLOTO or equivalent make as approved by the Engineer in charge and as per manufacturer specification: |
| 144 | 15 mm nominal bore. |
| 145 | 25 mm nominal bore. |
| 146 | Grading roof for water proofing treatment with |
| 147 | Cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size) |
| 148 | Cement mortar 1:3 (1 cement : 3 coarse sand) |
| 149 | Water proofing treatment on terrace with chemical traetment including cleaning of surface : (a) Filling the small cracks up to 10 mm in wall and roof with Dr Fixit Crack X range or equivalent (b) After drying the filled up area at least 8 to 10 hours apply Dr fixit Pidifin 2K (2 coats) or equivalent as per manufacturer specifications and direction of Engineer in charge. Please Enable Macros to View BoQ information |