| 1 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar |
| 2 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead |
| 3 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area beyond 3 sq. metres |
| 4 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge |
| 5 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles above 25 mm and up to 40 mm |
| 6 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) |
| 7 | 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) |
| 8 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 9 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 10 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer |
| 11 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats |
| 12 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works |
| 13 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shadeTwo or more coats on new work |
| 14 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-chargeProfile CFixing with adjustable lugs with split end tail to each jamb |
| 15 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Size of Tile 600x600 mm |
| 16 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 17 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 18 | Fixing flush door shutters of 40mm thickness made of with 19mm Green Ply finished with Decorative Laminate on both the faces with all necessary fittings etc, complete as directed by department. |
| 19 | Supplying,fitting and fixing of 12mm thick toughened glass for door and fixed glass for door and fixed glass with overhead panel (size 2.40mx1.20m) along with GEZE floor spring, GEZE handle 300mm patch floor locks,connecting patch etc.complete in all levels as specified and directed by the Department. |
| 20 | Providing, Fitting and fixing Office work station table made of grean ply board, sunmica fitted with Brass fitting, complete in all respect as specified and directed by the Department. |
| 21 | Providing erecting cutting and fixing of 420 mm depth free standing file cabinat/rack with laminated finished, erected/making to be made with 19 mm thick Greenply Plywood on all frame structure and required partition with self member as per tequired height with providing fixing of edge hinding in all plywood edges cultting and pasting with fixing for 1.5 mm thick decorative laminated sheet in both side of ply surface inluding all linedware feelings like nails, levicol, pesting tap, handle, lock, hinges, tower boll, magnate catcher etc as a complete with all necessary required materials and labour as directed by the concern department. |
| 22 | Supplying, fitting and fixing Johnson Zebra Roller Blinds (Combi Blackout) make and shade, design as per choice complete as specified and directed by the department at all levels. |
| 23 | Supply, Installation, Testing & Commissioning of a complete Smart Door System consisting of a K-Lite Aluminium Partition with Stealth Door, including all required aluminium profiles such as main portal profiles, vertical profiles and top–bottom door profiles, along with cover strips, gaskets, accessories, hinges, 12 mm toughened glass panels, silicon sealant, a 300 mm handle set, and all associated fixing materials as per manufacturer’s specifications (Make: Ozone or equivalent approved). The item also includes providing and integrating an Electro-Magnetic Lock with a Face Detection Access Control System, complete with power supply unit, brackets, wiring, sensor module, testing and commissioning. The work shall be executed in all respects, ensuring proper alignment, smooth operation, secure locking, finishing, and handing over of the fully functional smart door system. |
| 24 | Supply and installation of Stainless Steel Shelf Rack with 5 shelves, made from SS Grade 202 galvanized steel. Shelves: 0.8 mm thick; Support structure: 1.5 mm thick. Open on all sides with square hollow section frame, double-fold shelf ends, and smooth surface finish. Dimensions: 915 mm (W) x 460 mm (D) x 1675 mm (H); Ground clearance: 75 mm; Frame size: 40x40 mm. Supplied knocked down for site assembly. Complete as approve by Department. |
| 25 | Supply and installation of Steel Shelving Cabinet conforming to IS 3312. Dimensions: 1855 mm (H) x 910 mm (W) x 480 mm (D). Made of CR mild steel, HR1 grade as per IS 1079. Includes 4 adjustable shelves, 1 drawer, and 1 lockable locker. Powder-coated finish with plain butt hinges and brass alloy lock handle. Complete as approve by Department. |
| 26 | Supply, installation, testing and commissioning of a modular D-Frame based laboratory work bench system, fabricated from CRCA with pure epoxy coating and phosphating process, including reagent shelf made of CRCA with epoxy coating, height-adjustable levelers, and stainless-steel non-corrosive hinges. The system shall be suitable for both dry and wet laboratory applications and shall be factory pre-assembled. The work bench shall comply with SEFA-10 testing standards, and shall have overall dimensions approximately 308 × 75 × 150 cm (W × H × D) with certifications equivalent to BIFMA Level 2, GreenGuard, and GRIHA, and shall be supplied with a 1-year warranty. Complete as required and approve by Department. |
| 27 | Providing, fitting and fixing Decorative Partition Wall of Size 2.14x 2.00x0.16 made of green ply board, Vinear, Etching Glass fitted with all fittings, complete in all respect as specified and directed by the Department . |
| 28 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 29 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 30 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 31 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 32 | Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections butexcluding modular plate etc. as required.5/6 A switch |
| 33 | 15/16 A switch |
| 34 | 3 pin 5/6 A socket outlet |
| 35 | 6 pin 15/16 A socket outlet |
| 36 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 37 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 38 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm) |
| 39 | 3 Module (100mmX75mm) |
| 40 | 4 Module (125mmX75mm) |
| 41 | 6 Module (200mmX75mm) |
| 42 | 12 Module (200mm X 150mm) |
| 43 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door |
| 44 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 45 | Triple pole and neutral |
| 46 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required.2 run of cable |
| 47 | 3 run of cable |
| 48 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase ACSupply, earthing etc. complete as required. |
| 49 | Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. (hevells /bajaj or equivelent make) 250 MM SWEEP NON-METTALIC |
| 50 | Supplying of 3-Star Rated Inverter Hi-Wall split type air conditioning unit with Inverter Rottary Compressor, Cu Condenser Coil, Microprocessor based controller with Cordless Remote and R32/R410A . The scope of work will include initial gas charging , ODU , canvas connection , nitrogen flushing , pressure testing and electrical connection between lDU and ODU.as required and as directed by the department. ( Carrier /VOLTAS/diakin or equivalent considering the mother items rate and specification)a) 1.5 Ton Inverter Split AC |
| 51 | Supplying with fitting fixing of 2MP Bullet IP Camera for CCTV System as required and as directed by the department. ( cp plus/hik vision orv equivalent as approved by dept.) |
| 52 | Supplying with fitting fixing of 2MP Dome IP Camera for CCTV System as required and as directed by the department. ( cp plus/hik vision orv equivalent as approved by dept.) |
| 53 | Supplying with fitting fixing of 8-Ports Managed PoE Layer Network Switch in CCTV System as required and as directed by the department. ( Digisol/ D-link/ Netgear or equivalent as approved by dept.) |
| 54 | Supplying with fitting fixing of 6U LAN RACK in LAN/cctv System as required and as directed by the department. ( D-link/VELRACK or equivalent as approved by dept.) |
| 55 | Supplying with fitting fixing of Realtime Power ofBiometric Linux Based Access ControlSystemRealtime Power of Biometric, an Access Control System with TCP/IP basedcommunication, Liveness Detection, mountingbracket/accessoriesas required and as directed by the department. (realtime power or equivalent as approved by dept.) |
| 56 | Installation charge of Split type AC machine of 1.00 Ton to 2.00 Ton capacity |
| 57 | Providing Copper pipe including control cable fitting for Split /Cassetter AC as per required size inclduing Nitrile Insulation complete.For 1.5Tr to 2 Tr Capacity |
| 58 | Supplying with fitting and fixing of ready made powder coated MS frame for Split AC Outdoor Unit Installation inclduing anchor fastnuts complete for split ac upto 2Tr capacity a) for 1.0 Tr to 2.0 Tr Outdoor Unit |
| 59 | Supplying with fitting and fixing Voltage stabilizer of the following specification complete including making necessary connection.5.0 KVA Automatic Input 120-280 V Out put 200-240 V |
| 60 | Supplying including fitting fixing of AC Starter of 20 A Motor Starter for AC machine in the existing 2/3 Module modular box with front plate as directed by the department. Installation charge of Split type AC machine of 1.00 Ton to 2.00 Ton capacity Please Enable Macros to View BoQ information |