| 1 | Boundary Wall |
| 2 | Survey, Demarcation, Cleaning of bushes, Uprooting of ipomia and cutting of trees from the campus for alignment etc. complete. |
| 3 | Earth work excavation of foundation in Hard Soil within initial lead and lift etc. complete. |
| 4 | Filling Foundation and plinth with well graded sand including watering and ramming |
| 5 | C.C. (1:4:8) with 40mm size crusher broken granite metal in F&P etc. all complete. |
| 6 | Rigid & smooth centering and shuttering in foundation etc. all complete.(a) Column upto Plinth |
| 7 | (b) Column in Super Structure |
| 8 | M -20 grade R.C.C. using 20mm&down graded chips crusher broken Column base, Column & Plinth Band |
| 9 | Supplying, fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specification |
| 10 | Fly Ash Brick work having crushing strength not less than 75 Kg/cm2 with dimensional tolerance ± 8 percent in cement mortar (1:6) in F & P. |
| 11 | Fly Ash Brick work having crushing strength not less than 75 Kg/cm2 with dimensional tolerance ± 8 percent in cement mortar (1:6) in superstructure in ground floor |
| 12 | 15 Cm deep brick coping 23cm to 25cm thick walls including plastering (1:4) complete. |
| 13 | Providing 12 mm thick C.P. (1:6) on brick wall |
| 14 | Providing Cement washing 2 coats etc. Complete. |
| 15 | Finishing walls with water proofing cement paint of approved shade on new work 2 coats to give an even shade including cost of brushes and putty including cost of paint. |
| 16 | Repairing |
| 17 | Dismantling and removing 2.5 cm thick grading concrete from roof slab cleaning the surface lowering and removing the debris |
| 18 | 2.5cm.grading concrete (1:2:2) on roof slab using 6mm.size CBHG chips |
| 19 | Wall Priming one coats on new work with wall water bound primer of approved shade |
| 20 | Finishing walls with water proofing weather coat paint of approved shade |
| 21 | Finishing wall surface with Cement based wall putty (water based) of approved make and finish smooth |
| 22 | Wall painting two coats with Plastic emulsion paint of approved shade on new work to give an even shade. |
| 23 | Supplying all Materials,labour,T&P and fitting, fixining of Wash down water Closet (Europian type W.C pan) with Integral\\"S\\" or \\"P\\" trap conforming to IS 2556:Part 8-2004, to the floor with Wooden Plug And Chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc,,all complete as per specification and direction of the Engineer inchargr. (Without Seat &Cover) |
| 24 | 10 Liters P.V.C.low level Flushing Cystern |
| 25 | Supply, fitting and fixing of CP concealed screw down stop cock of 15mm diameter in ground floor |
| 26 | Supply, fitting and fixing of brass or G.M.fullway valve of following nominal diameter etc. complete including cost of all materials. 25mm dia |
| 27 | Supply, fitting and fixing of C.P. screw down bib cock (tap) of 15mm diameter in ground floor |
| 28 | 25mm dia PVC pipe in ground floor |
| 29 | 20mm dia PVC pipe in ground floor |
| 30 | 15mm dia PVC pipe in ground floor |
| 31 | Supplying all Materials,labour,T&P and fixing Rotational moulded polithylene cylindrical vertical water storage tanks (SYNTEX) of 1000ltr |
| 32 | Providingand fixing towall or ceilingand floor rigidUPVCpipes class IV(8kgf/cm²)/class III |
| 33 | Supply, Installation, Testing, and Commissioning of 32 Amp DP Main switches of following capacity (IS 13940 Part 3/1993 ) on existing surface / wall mountnting and complete with HRC Fuse links, interconnections, earthing, etc. as required as per direction of Engineer in Charge. Make SEIMENS/ HPL/ ANCHOR/ L&T/ HAVELS/ C & S/ RK (32 Amp DP) |
| 34 | Cost of 1.5hp submerssible pump (18 stage single phase) of any approved make with ISI mark |
| 35 | Cost of HDPE column pipe( 32mm, Schedule-80) |
| 36 | Cost of submersible cable (2.5 sq.mm.) of ISI marked |
| 37 | Accessoris of pump fittings(reducer,nipple,short piece,bore cover,etc.upto overhead tank |
| 38 | Staineless steel wire rope for suspending the pump |
| 39 | Cost of control panel of approved make for 1.5HP Submesrsible Pump |
| 40 | Installation charges for pumpset, control panel and accessories. |
| 41 | Cost of RCC Ring with cover of 1.2m dia 5 nos icluding fitting and fixing for spetic Tank |
| 42 | Supplying, fitting and fixing Anti-Skid ceramic tile in floors, treads of steps and landing |
| 43 | Providing and fixing Glazed Ceramic tiles in walls, dados and skirting and in rises of steps |
| 44 | CC Road |
| 45 | Earth work excavation of foundation in Hard Soil within initial lead and lift etc. complete. |
| 46 | Filling Foundation and plinth with well graded sand including watering and ramming |
| 47 | cement concrete (1:4:8) using 4 cm HG metal in F & P |
| 48 | cement concrete (1:2:4) using 12 cm HG metal |
| 49 | Filling Foundation and plinth with excavated materials |
| 50 | Filling Bitumen and cement juite fibre in expansion joints incl. cost of material, cement proportion (3:1) incl. cleaning before pouring 12 mm to 25 mm and 15 cm depth |
| 51 | Toilet |
| 52 | Excavation of foundation in Hard soil within 50m initial lead and 1.5m initial lift |
| 53 | Filling Foundation and plinth with well graded sand including watering and ramming |
| 54 | Cement Concrete(1:4:8) with 40 mm size Hard Granite Metal |
| 55 | Brick work with Fly Ash Brick in cement mortar (1:6) in foundation and plinth works |
| 56 | Brick Work with Fly Ash Bricks having crushing strength 75kg/sq.cm in cement mortar (1:6) in Super Structure |
| 57 | RCC Work M-20 grade with 20 mm and down grade HG chips (CB) including hoisting,lowering & laying concrete and compacting (a) Plinth Band and Column Base |
| 58 | (b) Column and Beam |
| 59 | (c)Lintel |
| 60 | (d) Chajja |
| 61 | (e) Roof |
| 62 | Straightening,Bending,Binding of M.S.Rod including cost of rod,Binding wire and transportation G.F |
| 63 | Filling Foundation and plinth with Excavated Earth |
| 64 | 12mm thick cement plaster in C.M(1:6)over brick work F & P |
| 65 | 16mm thick cement plaster in C.M(1:6)over brick work G.F. |
| 66 | 12 mm thick cement plastering C.M. (1: 6) G.F. |
| 67 | 6mm thick cement plaster in C.M(1:4) R CC surfaces G.F. |
| 68 | Finishing walls with water proofing weather coat paint ground floor |
| 69 | Wall painting two coats with Plastic emulsion paint of approved shade |
| 70 | 2.5 cm thick grading concrete (1:2:2) on roof slab with 6mm size CB hard granite chips |
| 71 | Supplying, fitting and fixing Anti-Skid ceramic tile in floors, treads of steps and landing on 20mm thick cement mortar(1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc required for the work all complete as per direction of Engineer-in-Charge. ( For New work Only) |
| 72 | Providing and fixing Glazed Ceramic tiles in walls, dados and skirting and in rises of steps on 12mm thick bed of cement plaster (1:3) joined with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing including cost of tile. |
| 73 | Laying of 110mm nominal diameter UPVC sewer line including cost of materials. |
| 74 | Supplying all Materials,labour,T&P and fitting, fixining of Wash down water Closet (Europian type W.C pan) with Integral\\"S\\" or \\"P\\" trap conforming to IS 2556:Part 8-2004, to the floor with Wooden Plug And Chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc,,all complete as per specification and direction of the Engineer inchargr. (Without Seat &Cover) |
| 75 | 10 Liters P.V.C.low level Flushing Cystern |
| 76 | 15 mm dia CP concealed Stop Cock |
| 77 | Supply, fitting and fixing of C.P. screw down bib cock (tap) of 15mm diameter in ground floor |
| 78 | Supplying fitting and fixing of FRP door frame of size 75X100mm including drilling holes in Masonry walls Data for door of size (21'-6\\"X6'-6\\")=15'-6\\"or 4.72Rmt |
| 79 | Supplying fitting of Factory made single Leaf Regid FRP composite door Shutter of 32mm thick,Laminated with GRP skins with wood grain finished fabricates using UV stabilised Isopthalic Gel Coat and layer of 450gsm E-glass chopped strand mat(csm) impregnated with Orthopathalic,Polyster resin including fitting all fixtures like hings,towerbolt,handle,aldrop with cost,conveyance and taxes of all materials and labour complete.Data for 1.88 sq.m Please Enable Macros to View BoQ information |