Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | CIVIL WORK 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 2 | 16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 3 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 4 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 5 | 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 6 | 4.10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 7 | 6.2 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:6.2.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 8 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 10 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts |
| 11 | 5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu-ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 12 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 13 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.7 Stairs, (excluding landings) except spiral-staircases |
| 14 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.19 Weather shade, Chajjas, corbels etc., including edges |
| 15 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.3 Suspended floors, roofs, landings, balconies and access platform |
| 16 | 5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 17 | HALF BRICK MASONRY6.12 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :6.12.2 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 18 | 9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).9.1.2 Sal wood |
| 19 | 9.5 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)9.5.1 Second class teak wood9.5.1.1 35 mm thick shutters |
| 20 | 9.23 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 21 | 21.0 ALUMINIUM WORK 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners ofrequired dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 21.1.1 For fixed portion21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 22 | 21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the costof EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 23 | 21.8 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.21.8.1 Upto 5mm depth and 5 mm width |
| 24 | 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):21.3.2 With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 25 | 10.31 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel. primer, all complete as per the direction of Engineer-In-charge. |
| 26 | 9.96.1 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm |
| 27 | 9.97.2 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 28 | 9.100.1 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm |
| 29 | 9.141 Providing and fixing PVC Door Frame of size 50x47 mm with a wall thickness of 5 mm (± 0.2 mm), made out of single piece extruded PVC profile, with mitred cut joints and joint with 2 nos of PVC bracket of size 190 mm x 100 mm long arms of cross section size 35 x 15 mm & self driven self taping screws, the vertical door profiles to be reinforced with 40x20 mm M.S. rectangular tube of 0.8 mm , including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5 mm PVC frame strip with PVC solvent cement on the back of the profile.The door frame to be fixed to the wall using 8 x100 mm long anchor fasteners complete, all as per manufacturer's specification and direction of Engineer -in- charge. |
| 30 | 9.142 35 mm thick factory made Solid panel PVC Door shutter, made out of single piece extruded soild PVC profiles, 5 mm (± 0.2 mm) thick, having styles & rails (except lock rail) of size 95 mmx 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side),having one side thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power, including reinforcing with MS tube of size 40 mm X 20 mm x 1 mm, joints of styles & rails to be mitered cut & joint with the help of PVC solvent cement, self driven self tapping screws & M.S. rectangular pipes bracket of size 190 mm X 100 mm of cross section size 35 mm x 17 mm x 1 mm at each corner.Single piece extruded 5 mm thick solid PVC Lock rail of size 115 mm x 35 mm, out of which 75 mm to be flat and 20 mm to be tapered at both ends, having 15 mm solid core in middle of rail section integrally extruded, fixing the styles & rails with the help of solvent and self driven self tapping screws of 125 mm x 11 mm, including providing 5 mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturer's specification and direction of Engineer-in-charge.9.142.2 Decorative finish (Wood grained finish) |
| 31 | 13.2 15 mm cement plaster on the rough side of single or half brick wall of mix :13.2.1 1:4 (1 cement: 4 fine sand) |
| 32 | 13.9 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.13.9.1 12 mm cement plaster |
| 33 | 13.4 12 mm cement plaster of mix :13.4.1 1:4 (1 cement: 4 coarse sand) |
| 34 | 13.16 6 mm cement plaster of mix :13.16.1 1:3 (1 cement : 3 fine sand) |
| 35 | 13.50 Applying priming coat:13.50.1 With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 36 | 10.3 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 37 | 13.50.3 With ready mixed red oxide zinc chromate primer ofapproved brand and manufacture on steel galvanised iron/ steel works |
| 38 | 13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 39 | 13.48 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm |
| 40 | 13.48.2 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 41 | 11.41.A Providing and laying Vitrified tiles in floor in different sizes (thickness tobe specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size11.41A.3.1 Size of Tile 600 x 600 mm |
| 42 | 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 43 | 4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stoneaggregate 20 mm nominal size derived from natural sources) over 75mmthick bed of dry brick ballast 40 mm nominal size, well rammed andconsolidated and grouted with fine sand, including necessary |
| 44 | 11.20 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).11.20.1 Light shade pigment using white cement |
| 45 | SANITARY INSTALLATION & INTERNAL WATER SUPPLY12.41 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.12.41.2 110 mm diameter |
| 46 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.12.42.3 Single tee with door12.42.3.2 110x110x110 mm |
| 47 | 12.42.5 Bend 87.5°12.42.5.2 110 mm bend |
| 48 | 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.18.8.1 15 mm nominal dia Pipes |
| 49 | 18.8.2 20 mm nominal dia Pipes |
| 50 | 18.8.3 25 mm nominal dia Pipes |
| 51 | 18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.18.9.5 40 mm nominal dia Pipes |
| 52 | 17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:17.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 53 | 17.3 Providing and fixing white vitreous china pedestal type water closet(European type) with seat and lid, 10 litre low level white vitreouschina flushing cistern & C.P. flush bend with fittings & C.I. brackets,40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :17.3.1 W.C. pan with ISI marked white solid plastic seat and lid |
| 54 | 17.73 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 55 | 17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 56 | 18.52 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.18.52.1 150 mm nominal size square 100 mm diameter of the inner hinged round grating |
| 57 | 18.50 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.18.50.1 15 mm nominal bore |
| 58 | 17.71 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 59 | 17.34 Providing and fixing toilet paper holder :17.34.1 C.P. brass |
| 60 | 17.9 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required:17.9.1 White glazed fire clay kitchen sink of size 600x450x 250 mm |
| 61 | 18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 62 | 17.35 Providing and fixing soil, waste and vent pipes :17.35.1 100 mm dia17.35.1.1 Sand cast iron S&S pipe as per IS: 1729 |
| 63 | 18.6.4 Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. External work18.6.4 PN - 16 Pipe, 40 mm OD (SDR-7.4) |
| 64 | 18.6.5 PN - 10 Pipe, 50 mm OD (SDR-11) |
| 65 | 18.6.6 PN - 10 Pipe, 63 mm OD (SDR-11) |
| 66 | 18.6.7 PN - 10 Pipe, 75 mm OD (SDR-11) |
| 67 | 18.6.8 PN - 10 Pipe, 90 mm OD (SDR-11) |
| 68 | 18.6.9 PN - 10 Pipe, 110 mm OD(SDR-11) |
| 69 | SEPTIC TANK (2 Nos.)2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m.2.8.1 All kinds of soil.SEPTIC TANK |
| 70 | SOAK PIT |
| 71 | 16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 72 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.10 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size |
| 73 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 74 | 5.9.3 Suspended floors, roofs, landings, balconies and access platform |
| 75 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.1 Foundations, footings, bases of columns, etc. for mass concrete |
| 76 | 5.1Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 77 | 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 78 | 11.6 Cement plaster skirting up to 30 cm height, with cement mortar 1:3(1 cement : 3 coarse sand), finished with a floating coat of neat cement.11.6.1 18 mm thick |
| 79 | DEEP TUBE WELL8.1.1 Preparation of site for placement of the drilling rig including excavation of mud pit, circulation drain, collection chamber etc. all complete as directed. |
| 80 | 8.1.3 Transportation of all ancillary equipments, camp materials, welding set, rig accessories etc. including cost of P.O.L. all complete as directed.(a) for less than 100.00 m |
| 81 | 8.1.4 Transportation of all store materials like pipes, strainer, cone, socket, clamp, bentonite etc. including cost of P.O.L. all complete as directed.(a) for less than 100.00 m (b) Beyond 100.00 m |
| 82 | 8.1.5 Transportation of air compressor with all accessories including cost of P.O.L. all complete as directed. (a) for less than 100.00 m (b) Beyond 100.00 m |
| 83 | 8.1.6 Transportation of P.O.L. all complete as directed. |
| 84 | 8.1.7 Construction of temporary accommodation and low cost sanitary facility for drilling staff including cost of camp materials viz. cots, tables, chairs, utensils, dresses, safety helmets etc. and dismantling the accommodation after completion of the work all complete as directed. |
| 85 | 8.1.8 Providing water supply facilities at drilling site all complete as directed.(a) By installing 1 Nos. of Singur hand pump |
| 86 | 8.3.1 a) Drilling with drill bit in overburden portion of soil formation including collection of soil sample at every 3.0 m depth wherever there is a change of strata in sample boxes with distinguishing marks upto the depth of rock formation and withdrawing the drill bit for lowering casing as directed with 245mm to 300 mmm dia drill bit |
| 87 | 8.3.2 b) Casing / sinking / lowering of 200 mm dia MS pipe including cost of pipe and labour charge for casing, welding of joint by welding machine and sinking by drilling rig in portion all complete as directed by department. |
| 88 | 8.3.3 c ) 'Drilling with drilling rig using D.T.H. in all kinds of rock formation including collection of sample at every 3.0 m depth of boring or wherever there is a change of strata in sample boxes with distinguishing marks upto a required depth of boring along with breaking rock fracture for desired discharge, withdrawing drilling rod and finishing the borehole by ramming upto a required dia minimum 150mm dia upto the bottom and washing the well as per direction of the department all complete including testing of yield and drawdown of SWL of the DTW ..... |
| 89 | MR-1 Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET 3 (Three Phase) with submersible cable complete as directed and specified by the deptt.Three phase Submersible motor pump set (Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guar suitable for 100 mm bore well and above. 1 HP STAGE 5 to 18 with MCB controlled Submersible motor pump set control panel. |
| 90 | DRAIN WORK2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m.2.8.1 All kinds of soil |
| 91 | 16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 92 | 4.1.10 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 93 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.3 Suspended floors, roofs, landings, balconies and access platform |
| 94 | 5.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 95 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 96 | 6.26 Brick work with common burnt clay selected F.P.S. (non modular) bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand)6.26.1 From ground level upto plinth level |
| 97 | 1.10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from |
| 98 | 11.6 Cement plaster skirting up to 30 cm height, with cement mortar 1:3, (1 cement : 3 coarse sand), finished with a floating coat of neat cement.11.6.1 18 mm thick |
| 99 | LANDSCAPING2.57 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water)2.57.1 Trees Plant |
| 100 | 2.57.2 Shrubs Plant |
| 101 | 2.57.3 Hedge Plant /Ground cover |
| 102 | 3.1 Providing and displaying of Aglaonema Butterfly having ht.30 cm 10 to 12 fresh, healthy and attractive colorful leaves, well developed in 25 cm size Earthen pot/Plastic pot & as per direction of the officer-in-charge. |
| 103 | 3.2 Providing and displaying of Aglaonema Ice ht.25 cm having 10 to 12 fresh, healthy and attractive colorful leaves, well developed in 25 cm size Earthen pot/Plastic pot & as per direction of the officer-in-charge. |
| 104 | 3.6 Providing and Displaying of Aglaonema Sam ht.30 cm well developed three in one, having 18 to 20 fresh, healthy and attractive colorful leaves in 35 cm size Earthen pot/Chali/Tray & as per direction of the officer-in-charge. |
| 105 | 3.16 Providing and displaying of Araucaria cookie having ht. 1.20 m to 1.35 m, straight, well developed, fresh and healthy with lush green leaves from bottom to top in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. |
| 106 | 3.21 Providing and displaying of Areca Palm having ht. 1.80 m to 2.10 m with 8 to 10 suckers, well developed, fresh and healthy with lush green foliage in 30 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. |
| 107 | 3.24 Providing and displaying of Brassia Variegated having ht. 30 cm to 45 cm, well developed with fresh and healthy foliage in 25 cm size of Earthen pot /Plastic pot. & as per direction of the officer-in-charge. |
| 108 | 3.26 Providing and displaying of Chamaedorea elegans palm having ht. 60 cm to 75 cm, well developed with fresh and healthy leaves in 25 cm size of Earthen pot/Plastic pot. & as per direction of the officer-in-charge. |
| 109 | 3.27 Providing and displaying of Croton Challenger variety having ht. 30cm and above, well developed with full of fresh and healthy leaves in 20 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. |
| 110 | 3.51 Providing and Displaying of Dracaena pendanus, well developed, having 6 to 8 suckers with healthy foliage in 25 cm size Earthen pot/Plastic pot & as per direction of the officer-in-charge |
| 111 | 3.88 Providing of Schefflera Green (three in one), mounted on moss stick 90 cm, well developed with full of fresh & healthy leaves from bottom to top with rich foliage in 25 cm size of Earthen pot/Plastic pot.as per direction of officer-in-charge. |
| 112 | 4.4 Providing and Displaying Antirrhinum Hybrid dwarf variety, specimen (8-10) with fresh & healthy foliage in full bloom well developed in 35 cm Earthen Tray/Challi Pot and as per direction of the officer-in-charge. |
| 113 | 4.6 Providing and Displaying Asiatic lilly hybrid variety (3 in one) in each pot having in full bloom 3 to 5 flowers 30 to 45 cm ht. well developed in 25 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge. |
| 114 | 4.10 Providing and Displaying Calceolaria hybrid variety in full bloom well developed with fresh & healthy foliage in 20 cm Earthen Pot/Plastic Pot as per direction of the officer-in-charge. |
| 115 | 4.14 Providing and Displaying Chrysanthemum single named variety in different colour well developed, having 45 to 60 cm ht., minimum 150 and above half bloom flowers well stacked with bamboo stick having three layer tiding by thread fresh and healthy foliage in 30 cm Earthen Pot and as per direction of the officer-in-charge. |
| 116 | 4.17 Providing and Displaying Cineraria long 45 to 60 cm ht., 8 to 10 branch with full bloom specimen plant with green painted stacking in 30 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge. |
| 117 | 4.23 Providing and Displaying Cyclamen hybrid variety specimen 5-6 in a pot, fresh & healthy in full bloom well developed in 35 cm Earthen Tray/ Nand. as per direction of the officer-in-charge. |
| 118 | 4.24 Providing and Displaying Dahlia double kenya variety in different colour well developed with 3 to 4 flowers in half bloom, good foliage stacked with Green painted Bamboo sticks, 45 to 60 cm height in 25 cm Earthen Pot/ Plastic Pot and as per direction of the officer-in-charge. |
| 119 | 4.28 Providing and Displaying Dianthus dwarf specimen 6-8 in a pot with fresh & healthy foliage in full bloom well developed in 35 cm Earthen Tray/Nand as per direction of the officer-in-charge. |
| 120 | 4.38 Providing and Displaying Marigold jaffri French orange/yellow/Russet colour well developed with fresh & healthy foliage with 60 to 75 flowers in bloom specimen plant 60 to 75 cm ht in 30 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge. |
| 121 | 4.46 Providing and Displaying Pansy Hybrid Sakata in different colour specimen 6-8 in a pot with fresh & healthy foliage in full bloom well developed in 35 cm Earthen Tray/ Nand as per direction of the officer-in-charge. |
| 122 | 4.55 Providing and Displaying Poinsettia dwarf multi head, having upto 30 cm ht., with 3 to 4 branches with fully different colored top with fresh & healthy foliage well developed in 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge. |
| 123 | 4.56 Providing and Displaying Primula Hybrid variety specimen 5-6 in each Pot with fresh & healthy foliage in full bloom different colour well developed in 35 cm Earthen Tray/ Nand as per direction of the officer-in-charge. |
| 124 | 4.58 Providing and Displaying Ranunculus Hybrid variety in different colour specimen 5-6 in each Pot with fresh & healthy foliage in full bloom well developed in 35 cm Earthen Tray/ Nand as per direction of the officer-in-charge. |
| 125 | 4.90 Bush Rose in different colour 2 to 3 healthy branch 30 cm and above ht. well developed with 8 or more flowers / flower buds in 20 cm Earthen pot / Plastic pot as per direction of the officer-in-charge. |
| 126 | 4.92 Providing and Displaying Creeper Rose variety 3 to 4 healthy branch 60 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge. |
| 127 | 4.93 Providing and Displaying Standard Rose (H.T. variety) 3 to 4 healthy branch 90 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge. |
| 128 | 5.5 Providing and Displaying Adenium Obesum grafted well developed with fresh & healthy 30 to 60 cm ht. in 25 cm size Earthen Pot/ Plastic Pot as per direction of the officer-in-charge |
| 129 | 5.6 Providing and Displaying Adenium Obesum well developed with fresh & healthy 4 to 5 branch 60 to 75 cm ht. in 40 cm size Earthen Pot/ Plastic Pot as per direction of the officer-in-charge. |
| 130 | 5.8 Providing and Displaying Bamboo Buddha vally variety with umbrella shape having 120 to 135 ht. with fresh & healthy foliage well developed in 40 cm Cement pot multy branch, bushy as per direction of the officer-in-charge. |
| 131 | 5.10 Providing and Displaying Bird of paradise well developed with fresh & healthy 90 to 120 cm ht in 30 cm Earthen Pot/ Plastic Pot as per direction of the officer-in-charge. |
| 132 | 5.11 Providing and Displaying Bismarckia Palm 115 to 180 cm ht., well developed 12 and above good color fresh and healthy leaves in 40 cm Cement Pot as per direction of the officer-in-charge. |
| 133 | 5.12 Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marry palmar, Cherry Blossom etc. well developed with fresh & healthy bushy in full bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of the officer-in-charge. |
| 134 | 5.15 Providing and Displaying Cycus revoluta specimen , having 45 to 50 fresh and healthy, leaves having 30cm to 35cm circumfrance of base stem well developed in 40 cm challi, as per direction of the officer-in-charge. |
| 135 | 5.17 Providing and Displaying Cyprus golden well shaped developed with good colored foliage fresh & healthy 60 to 75 cm ht in 30 cm Earthen Pot as per direction of the officer-in-charge. |
| 136 | 5.33 Providing and Displaying Golden Bottle brush Topiary well developed with fresh & healthy foliage 5 to 6 big ball 115 to 180 cm ht in 40 cm Cement Pot as per direction of the officer-in-charge. |
| 137 | 6.2 Providing and stacking of Alternanthera species of height 15 cm to 20 cm, full of branches and foliage in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. |
| 138 | 6.7 \Providing and stacking of Clerodendrum inerme of ht. 20 cm to 30 cm multibranched in 15 cm size of Earthen Pot/Plastic Pot & as per direction of theofficer-in-charge. |
| 139 | 6.14 Providing and stacking of Euphorbia milli hybrid variety, having ht. 30 cm to 45 cm with multi branch, full bloom, fresh and healthy leaves in 30 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. |
| 140 | 6.31 Providing and stacking of Tradescantia zebrina having in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. |
| 141 | 7.1 \Providing and stacking of Acacia auriculiformis of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge. |
| 142 | 7.2 Providing and stacking of Adansonia digitata (kalp vricksh) of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge. |
| 143 | 7.5 Providing and stacking of Azadirachta indica (Neem) of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge. |
| 144 | 7.11 Providing and stacking of Bottle palm of ht. 210-240 cm bottom girth 30-35 cm well developed in big HDPE bags. |
| 145 | 7.17 Providing and stacking of Cassia siamea of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. |
| 146 | 7.37 Providing and stacking of Ficus retusa well branched of height 120-135 cm. in big poly bags of size of 30 cm as per direction of the officer-in-charge. |
| 147 | 7.47 Providing and stacking of Ingla dulcis (Jungle Jalebi) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. |
| 148 | 7.52 Providing and stacking of Magnolia grandiflora of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge. |
| 149 | 7.59 Providing and stacking of Mimusops elengi (Maulsri) of height 180-195 cm., well developed with thick stem in big in big size HDPE bag as per direction of the officer-in-charge. |
| 150 | Providing and stacking of Bauhinia acuminata height 60-75 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge. |
| 151 | 8.7 Providing and stacking of Calliandra hybrida of height 105-120 cm., well branched, bushy in big size HDPE bag as per direction of the officer-in-charge. |
| 152 | 8.15 Providing and stacking of Dombeya mastersii of height 60-75 cm. with 4- 5 branches in bag of size 25 cm as per direction of the officer-in-charge. |
| 153 | 8.23 Providing and stacking of Ficus blackii (F.vivion) (bushy) of height 150-165 cm. with 8-10 branches and healthy foliage in earthen pots of size 30 cm as per direction of the officer-in-charge. |
| 154 | 8.49 Providing and stacking of Nerium oleander (kaner) of height 45-60 cm. with 3-4 branches in poly bags of size 20 cm as per direction of the officer-in-charge |
| 155 | 9.1 Providing and stacking of Allamanda cathartica of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. |
| 156 | 9.4 Providing and stacking of Bougainvillea (Variety Butiana, Lady Mary Baring, Mahara,Mohan,Scarlet Queen, Variegated, Glabra Formosa, Peruviana Odissi, Paratha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) of height 30 cm. to 45 cm. with 2-3 branches in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. |
| 157 | 9.6 Providing and stacking of Clerodendrum thomsoniae of height 30 cm.to 45 cm in 20 cm size of poly bag & as per direction of the officer-in-charge. |
| 158 | 9.10 Providing and stacking of Passiflora caerulea (Rakhi bel) of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. |
| 159 | ICBP ROAD16.78.2 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.16.78.2 With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 160 | 16.3.2 Supplying and stacking at site.16.3.2 63 mm to 45 mm size stone aggregate |
| 161 | 16.4 Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . |
| 162 | 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 163 | 16.91 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 16.91.2 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 164 | 16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 165 | 4.3.1 Centering and shuttering including strutting, propping etc. and removal of form work for :4.3.1 Foundations, footings, bases for columns |
| 166 | 4.1.3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 167 | Internal Electrification: 1.10: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.1.10.1 Group A |
| 168 | 1.55.1: Wiring for group controlled (looped) light point / fan point / exhaust fan point / call bell point (without independent switch etc.) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required,1.55.1 Group A |
| 169 | 1.14: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 170 | 1.14.2. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 171 | 1.14.3. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 172 | 1.14.4. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 173 | 1.14.10. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 174 | 1.24: Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.1.24.1. 5/6 amps switch |
| 175 | 1.24.3. 15/16 amps switch |
| 176 | 1.24.4. 3 pin 5/6 A socket outlet |
| 177 | 1.24.5. 6 pin 15/16 A socket outlet |
| 178 | 1.27: Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1.27.1 1 or 2 Module (75mmX75mm) |
| 179 | 1.27.2 3 Module (100mmX75mm) |
| 180 | 1.27.3 4 Module (125mmX75mm) |
| 181 | 1.27.4 6 Module (200mmX75mm) |
| 182 | 1.27.5 8 Module (125mmX125mm) |
| 183 | 1.27.6 12 Module (200mmX150mm) |
| 184 | 1.25: Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 185 | 1.33: Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 186 | 1.35: Installation,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 187 | 1.44: Installation,Testing, Commissioning of ceiling fan including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor, songle core cable etc. as required. |
| 188 | 1.50: Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.1.50.1 Upto 450 mm sweep |
| 189 | 1.57: Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 190 | 1.58: Supplying and fixing PVC batten / angel holder including connction etc. as required |
| 191 | 2.4.2: Supplying and fixing following way, horizontal type three pole and neural , sheet steel, MCB distribution board, 415V on surface/recess complete with tinned copper busbar, neutral bus bar, earth bar, din bar, interconnection, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way (4+18), double door |
| 192 | 2.10: Supplying and fixing 5A to 32A rating, 240/415V 10KA C curve, MCB suitable for inductive load of following pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.2.10.1. Single pole |
| 193 | 2.13: Supplying and fixing following rating, four pole 415V isolator in the existing MCB DB complete with connection, testing and commissioning etc. as required.40 A |
| 194 | 5.2: Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 195 | 5.9: Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 196 | 6.2: Providing and fixing of lighting arrester conductor finial made of 25mm dia 300mm long GI tube having single prong at top with 85mm dia thick GI base plate including holes etc. complete as required. |
| 197 | 6.7: Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet orsurface of wall for lightning conductor complete asrequired.(For horizontal run) |
| 198 | 6.8: Providing and fixing GI tape 20 mm X 3 mm thick on parapet or surface of wall for lighting conductor complete as required( For vertical run) |
| 199 | MR-1: Supplying of 36W LED tube, Surface/Suspension mounting General Purpose LED Battens in Extruded Aluminium housing with wide range of wattages to suite variety of application areas. IP40. THD: <10%, including all accessories as specified and directed by the deptt. (Crompton /Bajaj/Hevells Make) etc. |
| 200 | MR-2: Supplying of 20W LED tube, Surface mounting General Purpose LED Battens in Extruded aluminium housing with wide range of wattages to suite variety of application areas. THD: <10%, including all accessories as specified and directed by the deptt. (Crompton /Bajaj/Hevells Make) etc. |
| 201 | MR-3: Supplying of 15 W LED light, slim, pressure die-cast aluminium luminaire in powder coated white finish, ceiling-mounting in square / round profile including all accessories as specified and directed by the deptt. (Crompton /Bajaj/Hevells Make) etc. |
| 202 | MR-4: Supplying of 10W LED light, Surface mounting General Purpose LED Battens in Extruded aluminium housing with wide range of wattages to suite variety of application areas including all accessories as specified and directed by the deptt. (Crompton /Bajaj/Hevells Make) etc. |
| 203 | MR-5: Supplying of 1200 mm sweep Ceiling Fan with decorative blade or as directed by the Deptt. (Crompton /Bajaj/Hevells Make) etc. |
| 204 | MR-6: Supplying of 300 mm sweep Exhaust Fan etc. as directed by the Deptt. (Crompton /Bajaj/Hevells Make) etc. |
| 205 | MR-7: Supplying,with fitting & fixing of 4 KVA voltage stabilizer of following specification complete with necessary electrical connection etc. as required and as directed by the Department.(Microtec/equivalent) for 1.5 Ton A.C. 4.0 KVA, 140-290 Volt capacity |
| 206 | MR-8: Supplying,with installation of, testing and commi ssioning of Hi wall 5 star rating split inverter air conditioner of following capacity with cord less remote complete with copper pipe and electri cal connection etc. as required complete and as directed by the Department. (Voltus /Blue Star/Carrier Make) etc.1.5 Ton capacity |
| 207 | External Electrification:7.3.1: Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering.Upto 35 sq. mm |
| 208 | 9.1.32: Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4x10 sq. mm. (25mm) |
| 209 | 5.7: Supplying and laying 6 SWG GI wire at 0.50 meter below ground level for conductor earth electrode, including connection / termination with GI thimble etc. as required. |
| 210 | MR-1: Supply of following size XLPE insulated and PVC sheathed 1.1 KV grade Aluminium conductor armoured cable as specified and directed by deptt. (Havells/ polycab/ Gloster/ Finolex make as approved by the deptt.).4 core 10 sq mm |
| 211 | MR-2: Supplying including installation of the Octagonal poles shall be designed to withstand the maximum wind speed of 169 km/hr. The top loading i.e. area and weight of fixtures are to be considered to calculate maximum deflection of the poles and the same shall meet the requirement of BS:5649 Part VI 1982. |
| 212 | MR-3: Single arm bracket 1000mm long for 6 metre long Poles with boom angel 0 deg. |
| 213 | MR-4: Double arm bracket1000mm long for 6 metre long Poles with 90 deg deflection and boom angel 0 deg. |
| 214 | MR-5: Supply, fixing, testing and commissioning of LED type road light fittings suitable for mounting on 6.0 mtr high octagonal pole complete with all accessories and 40W/45W LED as per specification. Make: Philips / Crompton /Wipro |
| 215 | MR-6: Supplying and drawing of weather proof copper conductor flexible cable of the following size as directed and specified by the department.3 core 2.5 Sq.mm unarmoured cable |
| 216 | MR-7: Providing and fixing of 1800 mm long 20 mm dia GI rod earth electrode for individual Pole Earthing |
| 217 | Power Supply Works:11.3.4: Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.Above 10.00 metre and upto 12.00 metre |
| 218 | 13.1: Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required. |
| 219 | 13.2: Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required. |
| 220 | 13.4: Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required. |
| 221 | 13.6: Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required. |
| 222 | 13.7: Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required. |
| 223 | 13.8: Supplying and erection of a set of cross bracing FRLSame work for 11 KV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height, complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc (as per drawing) and painting with primer and finish paint as required |
| 224 | 13.9: Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required |
| 225 | 13.10: Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. |
| 226 | 13.11: Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required. |
| 227 | 13.13: Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. |
| 228 | 2.22: Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 229 | 5.2: Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (for Transformer, DG body earth & pole LA) |
| 230 | 5.4: Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. (for Transformer & DG neutral earth) |
| 231 | 6.14: Providing and laying GI tape 32 mm X 6 mm from earth electrode directly in ground as required. |
| 232 | 5.7: Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 233 | 7.1.3: Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.Above 95 sq. mm and upto 185 sq. mm |
| 234 | 9.1.27: Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 & 1/2 x 185.00 Sq. mm. (57mm) |
| 235 | MR-1: Supplying of the following specification as per IS:2713 : 410 SP hot dip Galvanized Steel tubular pole manufacturing out from electrically welded in 3 (three section having a base plate including providing all required building materials as directed and specified by the deptt. (BANSAL/SRP /Utkarsh / PARUTHI ENGR make) 410 SP 62 Length of pole = 12.00 metre., Length of sections, Bottom = 5.80 M, Middle = 3.10 M, Top = 3.10 M, Out side dia. & Thickness Bottom = 193.70 x 5.40 mm, Middle =165.10 x 4.50 mm, Top =138.70 x 4.50 mm |
| 236 | MR-2: Supplying and string up ACSR Rabbit conductor in the existing P.S.C./ M.S/ Galvanized pole with binding etc. as required and as directed by the department. Directed by the department. |
| 237 | MR-3: Supplying and fitting fixing of P.G. clamp for Rabbit conductor complete as required and as directed by the department. |
| 238 | MR-4: Supplying and fixing of 11 KV 400 A Gang operated switch with all accessories complete as required and as directed by the department. |
| 239 | MR-5: Supplying and fixing of 11 KV 150 A D.O. fuse set complete as required and as directed by the department. |
| 240 | MR-6: Supply, installation, testing and commissioning of 100 KVA,50Hz, 11/0.433 KV, 3 phase, Oil filled, Off Circuit tap changer, copper wound, out door type transformer complete including the payment to be made to power supply authority for supervision charge, labour charge, cost of L.T/H.T metering etc. (excluding the cost of load security) and making necessary arrangement for charging approval of the sub-station from the competent authority as directed and specified by the department. |
| 241 | MR-7: Supply, installation, testing and commissioning of Water Cooled Diesel Generator set coupled to suitable alternator of 100 KVA, 415 V, AC, 3-Phase 0.8 p.f. mounted on M.S. Fabricated base frame., M.S. fuel tank of required capacity., Residual Silencer., Standard Control Panel. Suitable batteries with lead., First fill of lube oil., Acoustic Enclosure complete with all accessories as specified and directed by the department or as per manufacturer. Kirloskar green/bliss, Leyland, Volvo Penta, Perkinson, Mahindra, Greaves, Escort engine and Kirloskar, Stamford, Leroy somer alternator. |
| 242 | MR-8: Supply of following size XLPE insulated and PVC sheathed 1.1 KV grade Aluminium conductor armoured cable as specified and directed by deptt. (Havells/polycab/ Gloster/ Finolex make as approved by the deptt.) .185.00 Sq. mm.3 & 1/2 Core armoured U.G. cable |
| 243 | MR-9: Supply, installation, testing & commissioning of Main LT Panel , fully compartmentaliszed cubicle type sheet clad indoor type, wall /floor mounted totally enclosed with IP52 degree of protection suitable for use on 415Volts 3-phase, 4 wire, 50 Hz system having required fault capacity, housed with incoming and outgoing, Aluminium busbars interconnection etc. with indication lamps, accessories etc. |
| 244 | MR-10: Supplying, Installtion, Testing and Commissioning of the accessories as required complete including payment of ASEB's supervision charge, cost of ASEB's materials etc (including payment of load security and cost of ASEB tested energy trivector Meter) |
| 245 | MR-11: Providing and fixing of 1800 mm long 20 mm dia GI rod earth electrode for individual Pole Earthing |
| 246 | Installation of CCTV:1.53: Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. 1.53.1 1 run of cable |
| 247 | 1.5: Wiring for light/ power plug with 2X4 sq. mm. FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 248 | 1.7: Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRIS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRIS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 1.7.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 249 | 1.24: Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as1.24.1 5/6 amps switch |
| 250 | 1.24.4 3 pin 5/6 amp socket outlet |
| 251 | 1.24.3 15/16 amp switch |
| 252 | 1.24.5 6 pin 15/16 amp socket outlet |
| 253 | 2.3: Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 2110 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator)2.3.2 2 6 way, Double door |
| 254 | 2.10: Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.2.10.1 Single pole |
| 255 | 5.4: Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 256 | 5.9: Supplying and laying 25 mm X 5 mm G.l strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with Gil. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.l. nut bolt & spring washer spaced at 50mm) |
| 257 | MR-1: Supplying, lnstallation, testing and commissisoning of IP Bullet Camera-Min Illumination : 0.04 Lux @ F 1.2, Built in fixed lens 3 mm, IP 66, 12 VDC,with audio recording and night visison facilities 2MP, Compression H.264-Honeywell/ Hikivision/ Panasonic or equivalent |
| 258 | MR-2: Supplying, lnstallation, testing and commissisoning of IP Dome Camera Min Illumination : 0.15 Lux @ F 1.2, Built in fixed lens : 8 mm, Compact Dome Camera (8mm) with audio recording and night vision facilities 2MP, Compression H.264Honeywell/Hikivision/Panasonic or equivalent |
| 259 | MR-3: Supplying, lnstallation, testing and commissisoning of NVR 32 Channel Honeywell/Hikivision/Panasonic or equivalent |
| 260 | MR-4: Supplying, lnstallation, testing and commissisoning of NVR 8 Channel Honeywell/Hikivision/Panasonic or equivalent |
| 261 | MR-5: Supplying, lnstallation, testing and commissisoning of Hard Disk Drive of 4 TB/each with alteast one month footage backup for H.264 Compression-JENY/SEAGATF make or equivalent |
| 262 | MR-6: Supplying, lnstallation, testing and commissisoning of LG Smart Television TV 32 inch Smart LED Category Smart Typical Brightness 400 500 LG /Samsung or euivalent make |
| 263 | MR-7: Supplying, lnstallation, testing and commissisoning of LG Smart Television TV 55 Inch LED Backlit LCD-Screen Size (Inches) 55 Resolution Category Smart Typical Brightness 400-500 |
| 264 | MR-8: Supplying, lnstallation, testing and commissisoning of HDPE PIPE |
| 265 | MR-9: Supplying, lnstallation, testing and comnlissisoninp, of 8 Port POE Switch of Netgear/ D-Link make |
| 266 | MR-10: Supplying, lnstallation, testing and commissisoning of Media Converter-Fiber to CAT 6 Converter |
| 267 | MR-11: Supplying, lnstallation, testing and commissisoning of 1 KVA UPS for CCTV with external battery icluding cables, connections and barriers |
| 268 | MR-12: Supplying, lnstallation, testing and commissisoning of 4U Rack Enclosures Networking/ Server Rack D-link make |
| 269 | MR-13: Supplying, lnslallation, testing and commissisoning of 42U Rack Enclosures SNS make |
| 270 | MR-14: Supplying, lnstallation, testing and commissisoning of 2 x RJ-45 Based Surge Connector and surge supressor |
| 271 | Installation of Wet Riser & Sprinkler System for Fire Fighting:18.1: Supplying, installing, testing and commissioning of Electic driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required:- (A) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520, (B) Suitable HP squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with class-'F' insulation, conforming to IS-325, (C) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required, (D) Suitable cement concrete foundation duly plastered with anti vibration pads.18.1.7 1620 Ipm at 88 m Head |
| 272 | 18.2: Supplying, installing, testing and commissioning of Diesel engine driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required:- (Diesel Driven Pump) (A) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520, (B) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts electric starting equepment, diesel tank, exhaust pipe extended upto 10 m otuside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, top solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. (C) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required, (D) Suitable cement concrete foundation duly plastered with anti vibration pads.18.2.7 1620 Ipm at 88 m Head |
| 273 | 18.3: Supplying, installing, testing and commissioning of Diesel engine driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required:- (Jockey Pump) (A) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (B) Suitable HP squirrel cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class pf protection for enclosure, horizontal foot mounted type with Class-'F' insulated, conforming to IS : 325. (C) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required, (D) Suitable cement concrete foundation duly plastered with anti vibration pads.18.3.4 300 Ipm at 88 m Head |
| 274 | 18.6: Providing laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS , refilling the trance etc. of following sizes complete as required.18.6.1 200 mm. dia (wall thickness = 6.3 mm) |
| 275 | 18.6.2 150 mm. dia |
| 276 | 18.7: Providing laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/ IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enael paint of required shade complete as required.18.7.1 25 mm. dia |
| 277 | 18.7.4 50 mm. dia |
| 278 | 18.11: Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/ gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required.18.11.6 150 mm. dia |
| 279 | 18.11.7 200 mm. dia |
| 280 | 18.12: Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gunmetal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required.18.12.2 50 mm. dia |
| 281 | 18.12.6 150 mm. dia |
| 282 | 18.12.7 200 mm. dia |
| 283 | 18.13: Supplying and fixing orifice plate made out of 6 mm. thick stainless steel (grade 304) with orifice of required size to be fitted between flance and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 284 | 18.14: Providing, installing, testing and commissioning of non-return valve of following sizes conforming to IS 5312 complete with rubber gaskes, GI bolts, nuts, washers etc as required.18.14.2 50 mm. dia |
| 285 | 18.14.7 150 mm. dia |
| 286 | 18.14.8 200 mm. dia |
| 287 | 18.15: Providing, installing, testing and commissioning of stainless steel Y-strainer fabricated out of 1,6 mm. thick stainless steel, Grade 304, sheet with 3 mm. dia holes with stainless steel flange.18.15.3 150 mm. dia |
| 288 | 18.16: Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required.18.16.1 Gun Metal |
| 289 | 18.19: Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as required for suitable dia MS pipe connection conforming to IS 904 as required.18.19.1 2 way 100 mm. dia M.S. Pipe |
| 290 | 18.21: Providing, installing, testing and commissioning of 15 mm. dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories.18.21.1 Pendent Sprinkler |
| 291 | INTERIOR WORK9.126 Providing and fixing 12 mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.9.126.1 Marine plywood conforming to IS: 710 |
| 292 | 12.45 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.45.2 12.5 mm thick tapered edge Gypsum moisture resistant board |
| 293 | Supplying with including fitting fixing of UPVC Wall Panelling or False Ceiling by SWISS PINE HS 05 etc. as directed by the Deptt. |
| 294 | FOR MODULER KITCHEN19mm 8x4 (Green Ply/Century Ply) BWP710 |
| 295 | Inner Micka |
| 296 | Fevicol 10Kg |
| 297 | Auto Hings |
| 298 | Handle 12\\" |
| 299 | Handle 6\\" |
| 300 | Acrylic Sunmica |
| 301 | Construction of Boundary Wall:2.8: Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil. |
| 302 | 11.2: Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. |
| 303 | 4.1: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.8 1:4:8 (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 304 | 5.22: Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level.5.22.1 Mild steel and Medium Tensile steel bars |
| 305 | 5.9: Centering and shuttering inluding strutting, propping etc end removal of the same5.9.1: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. |
| 306 | 5.9.5: Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 307 | 5.9.6: Columns, Pillars, Posts & Strut |
| 308 | 5.1: Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 309 | 5.2: Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing andreinforcement :5.2.2A 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 310 | 6.13: Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) |
| 311 | 13.5: 15 mm cement plaster on rough side of single or half brick wall of mix:13.5.1 1:4 (1 cement: 4 coarse sand) |
| 312 | 13.43: Applying one coat of water thinnable cement primer of approved brandand manufacture on wall surface :13.43.1 Water thinnable cement primer |
| 313 | 13.44: Finishing walls with water proofing cement paint of required shade :13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 314 | Construction of Gate:2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m.2.8.1 All kinds of soil |
| 315 | 2.25a Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 316 | 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 317 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 318 | 16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 319 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.1 Foundations, footings, bases of columns, etc. for mass concrete |
| 320 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 321 | 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 322 | 4.10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 323 | 11.5 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 324 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 325 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts |
| 326 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.19 Weather shade, Chajjas, corbels etc., including edges |
| 327 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.3 Suspended floors, roofs, landings, balconies and access platform |
| 328 | 5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu-ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 329 | 5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 330 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 331 | 5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 332 | 6.2 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:6.2.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 333 | 6.3 Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) :6.3.1 With F.P.S.(non modular) bricks |
| 334 | 9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).9.1.2 Sal wood |
| 335 | 9.5 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) 9.5.1 Second class teak wood9.5.1.1 35 mm thick shutters |
| 336 | 9.23 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 337 | 9.96.1 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm |
| 338 | 9.102 Providing and fixing aluminium casement stays, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete |
| 339 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :9.97.2 250x10 mm |
| 340 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :9.97.4 150x10 mm |
| 341 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :9.100.1 125 mm |
| 342 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :9.100.2 100 mm |
| 343 | 21.10 Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete. |
| 344 | 10.31 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel. primer, all complete as per the direction of Engineer-In-charge. |
| 345 | 13.2 15 mm cement plaster on the rough side of single or half brick wall of mix :13.2.1 1:4 (1 cement: 4 fine sand) |
| 346 | 13.4 12 mm cement plaster of mix : 13.4.1 1:4 (1 cement: 4 coarse sand)i) For Building- Inside wall |
| 347 | 13.16 6 mm cement plaster of mix :13.16.1 1:3 (1 cement : 3 fine sand) |
| 348 | 13.5O: Applying priming coat:13.50.1 With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 349 | 13.50.3: With ready mixed red oxide zinc chromate primer ofapproved brand and manufacture on steel galvanised iron/ steel works |
| 350 | 13.26 Providing and applying plaster of paris putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete. |
| 351 | 13.48: Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm. |
| 352 | 13.48.2 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 353 | 13.48.3: Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 354 | 11.41.A Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size11.41A.3.1 Size of Tile 600 x 600 mm |
| 355 | 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 356 | PAVER BLOCK WORK ALONG WITH GATE 4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 357 | 16.42 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete. |
| 358 | 11.20 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). 11.20.1 Light shade pigment using white cement |
| 359 | 16.7 Brick edging in full brick width and half brick depth includingexcavation, refilling and disposal of surplus earth lead upto 50 metres. 16.7.1 With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5 |
| 360 | Exterior Decoration:25.0 STRUCTURAL GLAZING ALUMINIUM COMPOSITE PANEL 25.2 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. (d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. |
| 361 | 10.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 362 | EARTH WORK2.25(a) Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 363 | FURNITURERegency visitor chair |
| 364 | Premium Lounge Chair |
| 365 | Door matt synthetic 400mmx600mm |
| 366 | Regency high back chair |
| 367 | Executive Table (72x36x30) |
| 368 | Table |
| 369 | Cabinet |
| 370 | Sofa( 3+1+1) |
| 371 | Side table |
| 372 | Centre table(Alice) |
| 373 | Book self |
| 374 | Glass Almirah(glass door units) |
| 375 | Steel Almirah |
| 376 | Office Table |
| 377 | Cabinet small |
| 378 | Cabinet big |
| 379 | Office storage |
| 380 | Cupboard |
| 381 | Aquaguard |
| 382 | Office Chair |
| 383 | 30 person wood u shaped wooden conference Table |
| 384 | Executive chaie for conference hall |
| 385 | Crokery Items for Directors Chembers |
| 386 | Visitors chair |
| 387 | 3 sester stainless steel visitor chair |
| 388 | Curtain |
| 389 | SONY TV Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail