| 1 | Plan 2 (Heightening and Repairing of Godown):-15.28: Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:15.28.1 G.S. Sheet sqm |
| 2 | 5.12: Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :5.12.1 Of area 3 sq. metres and below |
| 3 | 9.1: Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).9.1.1 Second Class teak wood |
| 4 | 15.18: Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 5 | 10.16: Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.10.16.1 Hot finished welded type tubes |
| 6 | 12.1: Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cuttingto size and shape wherever required.12.1.3 0.63 mm thick with zinc coating not less than 275 gm/ m² sqm |
| 7 | 5.22 A: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 8 | 5.9: Centering and shuttering inluding strutting, propping etc end removal of the same…5.9.6 Columns, Pillars, Posts & Strut |
| 9 | 6.13: Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) |
| 10 | 13.5: 15 mm cement plaster on rough side of single or half brick wall of mix: |
| 11 | 13.1: 12 mm cement plaster of mix :13.1.1 1:4 (1 cement: 4 fine sand) |
| 12 | 13.88: Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete sqm |
| 13 | 13.85: Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.13.85.1 With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre sqm |
| 14 | 13.48: Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm sqm |
| 15 | 9.9: Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.9.9.1 Second class teak wood9.9.1.1 35 mm thick sqm |
| 16 | 10.3: Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. sqm |
| 17 | 15.3: Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. cum 2928.10 |
| 18 | 21.1: Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :21.1.1 For fixed portion21.1.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 19 | 21.2: Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge.21.2.1 Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side |
| 20 | 21.3.2: With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 21 | 21.4: Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot andsingle piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.21.4.1 With stainless steel cover plate minimum 1.25 mm thickness |
| 22 | Electrical of Godown:-1.10: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.1.10.1 1.10.1 Group A |
| 23 | 1.14: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.1.14.1 1.14.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 24 | 1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 25 | 1.24: Supplying and fixing following modular type switch/ socket on the existing switch box/ cover including connections etcas required.1.24.1 1.24.1 5/6 amps switch |
| 26 | 1.24.3 15/16 A switch |
| 27 | 1.26: Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 28 | 1.27: Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1.27.2 3 Module (100mmX75mm) |
| 29 | 1.27.5 8 Module (125mmX125mm) |
| 30 | 1.28: Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required1.28.2 3 Module |
| 31 | 1.28.5 8 Module |
| 32 | 1.33: Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 33 | 1.34: Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 34 | 2.10: Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.2.10.1 Single pole |
| 35 | MR-1: Supplying with including fitting fixing of 18 Watt LED Tube Light etc. as directed by the Deptt . |
| 36 | Plan 4 (Modern Conference Room):-15.28: Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:15.28.1 G.S. Sheet sqm |
| 37 | 5.12: Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :5.12.1 Of area 3 sq. metres and below |
| 38 | 14.75: Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge. sqm |
| 39 | 9.1: Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).9.1.1 Second Class teak wood |
| 40 | 14.2: Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to thedumping ground, all complete as per direction of Engineer-in-Charge.14.2.1 Door chowkhats |
| 41 | Window chowkaths |
| 42 | 14.15: Renewing wooden battens in roofs, including making good the holes in wall and painting with oil type wood preservative of approved brand and manufacture complete, including removal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 43 | 12.1: Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cuttingto size and shape wherever required.12.1.3 0.63 mm thick with zinc coating not less than 275 gm/ m² sqm |
| 44 | 10.3: Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 45 | 13.88: Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete sqm |
| 46 | 13.8: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 47 | 13.48: Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm sqm |
| 48 | Analysis(a) : Providing, fitting and fixing Door Shutter made of 32mm ply and finish with veneer sheet all complete as per site-icharge or engineer instruction. |
| 49 | Analysis(b): Godrej Mortise Lock Handle Lock Set for Main & Internal Doors NEH 20 Home Décor Handle 9 Inch Lockbody 60mm 1CK Cylinder Knob from Inside Key Outside/equivalent |
| 50 | 9.72: Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :9.72.1 75x40x2.5 mm (ordinary type) |
| 51 | 9.74: Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :9.74.1 250x10 mm |
| 52 | 13.52: Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.13.52.1 On steel work |
| 53 | 15.3: Demolishing R.C.C. work manually/ by mechanical means includingstacking of steel bars and disposal of unserviceable material within50 metres lead as per direction of Engineer - in- charge. |
| 54 | 11.41A.3: Glazed Vitrified tiles Matt/Antiskid finish of size11.41A.3.1 Size of Tile 600 x 600 mm |
| 55 | 8.25: Providing and fixing 2nd class teak wood plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface.8.25.1 40 mm thick sqm |
| 56 | 13.116: Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then .......compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) |
| 57 | L/S: Providing and Fixing acoustic panel over 6 mm ply and in interior,glass fibre fixed with wire mesh (as directed by engineer in charge) |
| 58 | Furniture for Conference Room:-Revolving Chairs Godrej, Nilkamal or equivalent brand |
| 59 | Visitors Chairs Godrej, Nilkamal or equivalent brand |
| 60 | High Back Boss Chairs Godrej, Nilkamal or equivalent brand |
| 61 | Window blinds Chic corbed or equivalent brand |
| 62 | Door Curtain |
| 63 | U - shped 20 seater Conference Table |
| 64 | Floor carpet |
| 65 | Conference Delegate unit (Mic) with cable |
| 66 | Electrical of Godown:-1.10: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.1.10.1 1.10.1 Group A |
| 67 | 1.10.2 Group B |
| 68 | 1.10.3 Group C |
| 69 | 1.14: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.1.14.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 70 | 1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 71 | 1.14.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 72 | 1.24: Supplying and fixing following modular type switch/ socket on the existing switch box/ cover including connections etcas required.1.24.1 1.24.1 5/6 amps switch |
| 73 | 1.24.3 15/16 A switch |
| 74 | 1.24.4 3 pin 5/6 A socket outlet |
| 75 | 1.24.5 6 pin 15/16 A socket outlet |
| 76 | 1.26: Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 77 | 1.27: Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1.27.2 3 Module (100mmX75mm) |
| 78 | 1.27.5 8 Module (125mmX125mm) |
| 79 | 1.27.6 12 Module (200mmX150mm) |
| 80 | 1.28: Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required1.28.2 3 Module |
| 81 | 1.28.5 8 Module |
| 82 | 1.28.6 12 Module |
| 83 | 1.33: Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 84 | 1.34: Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 85 | 2.3: Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 86 | 2.10: Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.2.10.1 Single pole |
| 87 | 2.12: Supplying and fixing following rating, double pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.2.12.2 63 A |
| 88 | MR-1: Supplying with including fitting fixing of 18 Watt LED Tube Light etc. as directed by the Deptt . |
| 89 | MR-2: Supplying with including fitting fixing of LED Bulb 9Watt etc. as derected by Deptt. |
| 90 | MR-3: Supplying with including fitting fixing of Recessed mount Ceiling light 15 watt. etc. as directed by the Department. |
| 91 | MR-4: Supplying with including fitting fixing of BLDC Ceiling fan 1200mm etc. as directed by the Deptt. |
| 92 | MR-5: Supplying with including fitting fixing of 1.5 ton A.C etc. as directed by the Deptt. |
| 93 | MR-6: Supplying,with fitting & fixing of 3 KVA voltage stabilizer of following specification complete with necessary electrical connection etc. as required and as directed by the Department. (Microtec /equivalent). |
| 94 | MR-7: Supplying with fitting & fixing of A.C/ Motor Starter Switch 240V-50Hz 43MRWH3009 25A Motor Starter complete with necessary electrical connection etc. as required and as directed by the Department. (Orient / Havell/ Bajaj Make). |
| 95 | Toilet Block of Conference Hall:-2.8: Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil |
| 96 | 2.25(a): Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 97 | 16.12: Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. |
| 98 | 4.1.6: 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 99 | 5.22: Steel reinforcement for R... Work inluding sraitaning, leaning utting and bending to proper shape plaing in position and binding up to plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 100 | 5.22.A: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 101 | 5.9: Centering and shuttering inluding strutting, propping etc end removal of the same5.9.1 Foundation Footing, base of column etc. For mass concrete. |
| 102 | 5.9.5: Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 103 | 5.9.6: Columns, Pillars, Posts & Strut |
| 104 | 5.9.3: Suspended floors, roofs, landings, balconies and access platform |
| 105 | 5.9.19: Weather shade, Chajjas, corbels etc., including edges |
| 106 | 5.1: Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 107 | 5.2: Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 108 | 5.3: Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 109 | 6.1: Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 110 | 6.13: Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.6.13.1 Cement mortar 1:3 (1 cement :3 coarse sand) |
| 111 | 10.13: Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.10.13.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 112 | 9.20: Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.9.20.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 113 | 9.74: Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : |
| 114 | 14.41: Providing and fixing 85x42 mm chromium plated brass pull bolt lock with necessary chromium plated brass screws, nuts, bolts and washers etc. complete. |
| 115 | 10.16: Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.10.16.3 Electric resistance or induction butt welded tubes |
| 116 | 12.50: Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 117 | 13.5: 15 mm cement plaster on rough side of single or half brick wall of mix:13.5.1 1:4 (1 cement: 4 coarse sand) |
| 118 | 11.41A: Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.11.41A.3: Glazed Vitrified tiles Matt/Antiskid finish of size11.41A.3.1 Size of Tile 600 x 600 mm |
| 119 | 8.31: Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 120 | 13.8: 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix :13.8.2 1:4 (1 cement: 4 fine sand) |
| 121 | 13.46: Finishing walls with Acrylic Smooth exterior paint of required shade :13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 122 | 11.20: Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 123 | 17.3: Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :17.3.1 W.C. pan with ISI marked white solid plastic seat and lid |
| 124 | 17.4: Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :17.4.1 One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 125 | 17.6: Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required :17.6.1 Single squatting plate with 5 litre P.V.C. automatic flushing cistern |
| 126 | 17.7: Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:17.7.4 White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 127 | 17.69: Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.17.69.1 Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms |
| 128 | 17.73: Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 129 | 17.35: Providing and fixing soil, waste and vent pipes :17.35.1 100 mm dia17.35.1.1 Sand cast iron S&S pipe as per IS: 1729 |
| 130 | 18.8: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.18.8.1 15 mm nominal dia Pipes |
| 131 | 18.9: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work18.9.3 25 mm nominal dia Pipes |
| 132 | 18.15: Providing and fixing brass bib cock of approved quality :18.15.1 15 mm nominal bore |
| 133 | 18.16: Providing and fixing brass stop cock of approved quality :18.16.1 15 mm nominal bore |
| 134 | 18.48: Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 135 | Repairing and Renovation of EM Block:-15.28: Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:15.28.1 G.S. Sheet sqm |
| 136 | 5.12: Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :5.12.1 Of area 3 sq. metres and below |
| 137 | 9.1: Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).9.1.1 Second Class teak wood |
| 138 | 14.2: Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to thedumping ground, all complete as per direction of Engineer-in-Charge.14.2.1 Door chowkhats |
| 139 | Window chowkaths |
| 140 | 14.15: Renewing wooden battens in roofs, including making good the holes in wall and painting with oil type wood preservative of approved brand and manufacture complete, including removal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 141 | 12.1: Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cuttingto size and shape wherever required.12.1.3 0.63 mm thick with zinc coating not less than 275 gm/ m² sqm |
| 142 | 6.13: Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) |
| 143 | 13.5: 15 mm cement plaster on rough side of single or half brick wall of mix: |
| 144 | 13.88: Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete sqm |
| 145 | 13.85: Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.13.85.1 With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre sqm |
| 146 | 13.48: Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm sqm |
| 147 | 9.9: Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.9.9.1 Second class teak wood9.9.1.1 35 mm thick sqm |
| 148 | 9.74: Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :9.74.1 250x10 mm |
| 149 | 13.52: Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.13.52.1 On steel work |
| 150 | 9.3: Providing wood work in frames of false ceiling, partitions etc. sawn andfixed in position with necessary stainless steel screws etc.9.3.2 Kiln seasoned and chemically treated hollock wood cum |
| 151 | 12.26: Providing and fixing plain multipurpose cement board(Hight pressuresteam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately).12.26.1 6 mm thick Cement fiber board as per IS: 14862 sqm |
| 152 | 15.3: Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. cum 2928.10 |
| 153 | 11.41A: Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.11.41A.3: Glazed Vitrified tiles Matt/Antiskid finish of size11.41A.3.1 Size of Tile 600 x 600 mm |
| 154 | Mk. Rt./: Providing, fitting and fixing Wall panel made of 12mm ply and finish with veneer sheet all complete as per site-icharge or engineer instruction. |
| 155 | Sanitary Works for EM Block:Analysis: SINGLE PIECE-WC JAQUAR/HINDWARE |
| 156 | Analysis: FLEXIBLE TUBE 12mm DIA. & 1.5M LONG WITH JAQUAR/HINDWARE |
| 157 | Analysis: HAND SHOWER 95X95mm SQUARE SHAPE JAQUAR/HINDWARE |
| 158 | Analysis: EXPOSED SHOWER PIPE ROUND SHAP JAQUAR/HINDWARE |
| 159 | Analysis: SOAP DISH HOLDER JAQUAR/HINDWARE |
| 160 | Analysis: GLASS SHELF JAQUAR/HINDWARE |
| 161 | Analysis: TOWEL RING SQUARE JAQUAR/HINDWARE |
| 162 | Analysis: SINGLE TOWEL RAIL JAQUAR/HINDWARE |
| 163 | Analysis: SOAP DISPENSER WITH GLASS BOTTLE JAQUAR/HINDWARE |
| 164 | Analysis: TOILET ROLL HOLDER JAQUAR/HINDWARE |
| 165 | Analysis: ANGULAR STOP COCK WITH WALL FLANGE JAQUAR/HINDWARE |
| 166 | Analysis: 2 WAY BIB COCK WITH WALL FLANGE JAQUAR/HINDWARE |
| 167 | Analysis: FAUCET JAQUAR/HINDWARE |
| 168 | Analysis: PILLAR COCK JAQUAR/HINDWARE |
| 169 | Analysis: SINGLE LEVER WALL MIXER 3-IN-1 SYSTEM JAQUAR/HINDWARE |
| 170 | Analysis: OVERHEAD SHOWER SQUARE SHAPE JAQUAR/HINDWARE |
| 171 | Analysis: WALL BRACKET FOR HAND SHOWER JAQUAR/HINDWARE |
| 172 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Oval shape 450x350 mm (outer dimensions) |
| 173 | Providing and fixing soil, waste and vent pipes 100 mm diaSand cast iron S&S pipe as per IS: 1729 |
| 174 | Water Supply works for EM Block:-18.8: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.18.8.1 15 mm nominal dia Pipes |
| 175 | 18.8.2 20 mm nominal dia Pipes |
| 176 | 18.8.3 25 mm nominal dia Pipes |
| 177 | 18.9: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work18.9.1 15 mm nominal dia Pipes |
| 178 | 18.9.2 20 mm nominal dia Pipes |
| 179 | 18.9.3 25 mm nominal dia Pipes |
| 180 | 18.20: Providing and fixing brass ferrule with C.I. mouth cover includingboring and tapping the main :18.9.1 15 mm nominal bore |
| 181 | 18.20.2 20 mm nominal bore |
| 182 | 18.20.3 25 mm nominal bore |
| 183 | 18.22: Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :18.22.2 150 mm diameter |
| 184 | 18.88A.1: For 22mm x 15 mm outer dia pipe each |
| 185 | 18.88A.3: For 28 mm x 22 mm outer dia pipe |
| 186 | 18.90A: Providing and fixing required Stainless Steel Fitting of press fit design of grade 316L as per IS 6911:2017 and conforming to EN-10312 standards with V-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Elbow 90°18.90A.1 For 15 mm outer dia pipe each |
| 187 | 18.90A.2 For 22 mm outer dia pipe each |
| 188 | 18.90A.3: For 35 mm outer dia pipe each |
| 189 | 18.92A: Providing and fixing required Stainless Steel Fitting of press fit design of grade 316L as per IS 6911:2017 and conforming to EN-10312 standards with V-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Equal Tee18.92A.1 For 15 mm outer dia pipe |
| 190 | 18.92A.2 For 22 mm outer dia pipe |
| 191 | 18.48: Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 192 | Sptik Tank for EM Block (2 Nos.):-2.6: Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting ou tand disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer in charge.2.6.1 All kinds of soil |
| 193 | 16.12: Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 194 | 4.1: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level :4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources |
| 195 | 4.1.5: 1:3:6 (1 Cement : 3 coarses and (zone-III) derived from natural sources: 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 196 | 4.3: Centering and shuttering including strutting, propping etc. andremoval of form work for :4.3.1 Foundations, footings, bases for columns |
| 197 | 5.1: Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived fromnatural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources |
| 198 | 5.9: Centering and shuttering including strutting, propping etc.and removalof form for5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 199 | 5.22: Steel reinforcement for R.C.C.work including straightening, cutting,bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 200 | 6.1: Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in:6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 201 | 6.12: Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in foundations and plinth in :6.12.1 Cement mortar 1:3 (1 cement : 3 coarse sand) |
| 202 | 13.8: 15 mm cement plaster on rough side of single or half brick wall finishedwith a floating coat of neat cement of mix :13.8.1 1:3 (1 cement: 3 fine sand) |
| 203 | 5.12: Providing, hoisting and fixing above plinth level upto floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but, excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources) |
| 204 | 19.32: Making soak pit 2.5 m diameter 3.0 metre deep with 45x45 cm dry brick honey comb shaf twith bricks and S.W. drain pipe 10 0mm diameter, 1.8 m long complete as per standard design.19.32.1 With common burnt clay F.P.S (non modular) bricks of class designation 7.5 |
| 205 | 17.35: Providing and fixing soil, waste and vent pipes :17.35.1 100 mm dia17.35.1.1 Sand cast iron S&S pipe as per IS: 1729 |
| 206 | 17.36: Providing and filling the jointswith spun yarn, cement slurry andcement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes17.36.1 100 mm dia pipe |
| 207 | Land Development:2.25(a): Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 208 | Construction of ICBP Approach Road:-16.78: Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 |
| 209 | 16.3.1: Supplying and stacking at site. 90 mm to 45 mm size stone aggregate. |
| 210 | 16.4: Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density |
| 211 | 16.92.1: Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & direction of Engineer in-Charge. b. 80mm thick Cement concrete paver block of M-30 grade with approved colour, design & pattern. |
| 212 | 5.9.2: Centering and shuttering including strutting, propping etc. and removal of form for : b. Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 213 | 4.1.3: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : c. 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 214 | Heightening of North Side Wall:2.8: Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil. |
| 215 | 16.12.1: Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 216 | 4.1: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.3 :2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 217 | 5.9: Centering and shuttering inluding strutting, propping etc end removal of the same5.9.6: Columns, Pillars, Posts & Strut |
| 218 | 5.9.5: Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 219 | 5.22.A: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 220 | 5.1: Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 221 | 6.8: Brick work 7 cm thick with common burnt clay F.P.S. (non modular) brick of class designation 7.5 in cement mortar 1:3 (1 cement : 3 coarse sand) in superstructure above plinth level and upto floor five level. |
| 222 | 13.2: 15 mm cement plaster on the rough side of single or half brick wall of mix :13.2.1 1:4 (1 cement: 4 fine sand) |
| 223 | 13.1: 12 mm cement plaster of mix :13.1.1 1:4 (1 cement: 4 fine sand) |
| 224 | 13.43: Applying one coat of water thinnable cement primer of approved brandand manufacture on wall surface :13.43.1 Water thinnable cement primer |
| 225 | 13.44: Finishing walls with water proofing cement paint of required shade :13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 226 | Construction of Sentry Post (2 Nos):2.8: Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil. |
| 227 | 16.12.1: Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 228 | 4.1.6 : 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 229 | 5.22: Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 230 | 5.22A: Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 231 | 5.9: Centering and shuttering inluding strutting, propping etc end removal of the same5.9.1 Foundation Footing, base of column etc. For mass concrete. |
| 232 | 5.9.5: Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 233 | 5.9.6: Columns, Pillars, Posts & Strut |
| 234 | 5.1: Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 235 | 5.2: Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 236 | 10.16: Steel work in built up tubular (round, square or rectangular hollow tubesetc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.10.16.1 Hot finished welded type tubes |
| 237 | 12.1: Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cuttingto size and shape wherever required.12.1.3 0.63 mm thick with zinc coating not less than 275 gm/ m² |
| 238 | 12.4: Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.12.4.2 0.63 mm thick with zinc coating not less than 275 gm/m² |
| 239 | 6.12: Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in foundations and plinth in :6.12.2 Cement mortar 1:4 (1 cement :43 coarse sand) |
| 240 | 13.5: 15 mm cement plaster on rough side of single or half brick wall ofmix:13.5.1 1:4 (1 cement: 4 coarse sand) |
| 241 | 13.43: Applying one coat of water thinnable cement primer of approved brandand manufacture on wall surface :13.43.1Water thinnable cement primer |
| 242 | 13.44: Finishing walls with water proofing cement paint of required shade :13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 243 | Street Light:MR-1: Supply, Installation and Commissioning of 30 W Solar Two-In-One(Semi Integrated) LED street light System with Poly Crystalline PV Panel, output 125lm/W, Battery 30Ah, Type of Battery :12.8V LiFePo4, Panel-125Wp and 7m Octagonal Pole. as required and as directed by the Department (Surya/Orient/Bajaj/Havells or equivalent). |
| 244 | Fire Extinguiser:Supply & fixing of 6 Kg ABC type dry power extinguisher consisting of welded MS cylindrical body with discharge valve, nozzle and hanging arrangement complete conforming to IS:15683 |
| 245 | Providing & fixing 4.5kg CO2 type (ISI marked) extinguisher including all accessories with wall bracket & raw plug confirming to IS:940 |
| 246 | Supply of Furniture:Revolving Chairs best quality |
| 247 | Visitors Chairs best quality |
| 248 | Executive Office table best quality |
| 249 | Window blinds best quality |
| 250 | Door Curtain best quality |
| 251 | 3+1+1 Seater sofa best quality |
| 252 | Centre Table best quality |
| 253 | Office Table |
| 254 | Office Wooden Chair with cushion |
| 255 | Visitors Chair |
| 256 | 2 door Steel Almirah |
| 257 | Iron file Rack |
| 258 | Iron and Wood Table Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail