| Sl. No. | Item Description |
| 1 | Dismantling Asbestos Cement including ridge (corrugated, semicorrugated etc) sheets in roof covering complete all as directed. |
| 2 | S&F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa & minimum AZ @150 gm/sqm (be coated with hot dip alloy of 55% aluminium,43.5% Zinc,1.5% Silicon and finished with resin coat on both surface @ 150gm/sqm of coating both surfaces) as in roof covering/cladding to wall, fixed with self tapping screws complete all as directed. |
| 3 | S&F for Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa & minimum AZ @150 gm/sqm (be coated with hot dip alloy of 55% aluminium,43.5% Zinc,1.5% Silicon and finished with resin coat on both surface @ 150gm/sqm of coating both surfaces) as in roof covering/cladding to wall, fixed with self tapping screws complete all as directed. |
| 4 | Dismantling wall and ceiling boarding of any descripion , thickness incl. cover fillets complete all as directed. |
| 5 | M&L for providing aluminium snap Grid frame work for false ceiling with of size 605X605 mm ,using Main and cross tee of size 36.5mmX25mmX1.4mm, weighing 0.24 kg/RM and 23.5mmX36.4mmX1.4mm weighing 0.191Kg/RM respectively, The snap grid shall be supported at end all along the wall with aluminium anodised angle of size 40mmX25mmX2mm weighing 0.36Kg/RM. The snap grid shall be fixed to ceiling supporting hangers consisting of 2mm dia MS wire/GI wire, J bolts, nuts and washers as per manufacturer's instruction complete all as directed. |
| 6 | S&F Non asbestos fibre cement building board 4 mm thick in ceiling fixed or laid/inserted to timber /GI/Aluminium frame work with screw complete all as spcified. |
| 7 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as directed. |
| 8 | M&L Vitrified ceramic tiles Dark shade 9-10 mm thick (square/rectangular) polished, area of each tiles not exc 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed In white or coloured cement to match the shade of tiles, laid over and including 15mm thick cement screed base in CM (1:6), complete all as directed. |
| 9 | - ditto all as per Ser item No 08 above including 10 mm thick cement screed bed in CM (1:6) but on vertical surface such as skirting/ risers etc complete all as directed. |
| 10 | M&L coloured ceramic glazed tiles 375x250x7mm/ 450x300x7mm thick as in dado/skirting etc including 10 mm thick rendering in CM 1:4, set & jointed in neat cement slurry & pointed in white or coloured cement slurry & pointed in white or coloured cement complete all as directed. |
| 11 | M&L for non skid coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc over & including 15mm thick screed bed in CM 1:4, set & jointed in neat cement slurry and pointed with white or coloured cement to match complete all as directed. |
| 12 | Demolition of brick work build in cement mortar including all quoins, arches, pillars, complete all as directed. |
| 13 | M&L brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as directed. |
| 14 | -ditto- all as per Ser item 13 above here in before but except bricks, using old serviceable brick as retrieved complete all as directed. |
| 15 | M&L Cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in levelling course, coping, window cill etc complete all as directed. |
| 16 | Taking down cement or cement lime plaster at any position including raking out joints, hacking for key and scrubbing down with water complete all as directed. |
| 17 | M&L 15mm thick cement plastering in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished complete all as directed. |
| 18 | Rendering 15mm thick on brick or concrete surface in Cement mortar (1:4) finishing external surface even and smooth w/o using extra Cement complete all as directed. |
| 19 | M&L for 5 mm thick cement plaster in cement mortar 1:3 for ceiling, finished even & smooth without using extra cement complete all as directed. |
| 20 | M&L for preparing the newly surface of any description not otherwise described over 10 cm width or girth on steel surface and applying two coats of synthetic enamel paint over one coat of pink primer all as directed. |
| 21 | M&L for complete removal of old treatment from walls and applying two coat of oil bound distemper (OBD) white or tinted over one coat of alkali resistant primer, over and including 2mm thick wall care putty and sanding and applying by pump roller applicator complete all as directed. |
| 22 | M&L for complete removal of old treatment from ceiling and applying two coat of oil bound distemper (OBD) white or tinted over one coat of alkali resistant primer applying by pump roller applicator complete all as directed. |
| 23 | M & L preparation of newly plastered surfaces of wall providing and applying two coat of oil bound distemper (OBD) white or tinted over one coat of alkali resistant primer, over and including 2mm thick wall care putty and sanding and applying by pump roller applicator complete all as directed. |
| 24 | M & L preparation of newly plastered surfaces of ceiling providing and applying two coat of oil bound distemper (OBD) white or tinted over one coat of alkali resistant primer, by pump roller applicator complete all as directed. |
| 25 | M & L preparation of newly plastered surfaces of walls/Chajja/lintel and applying two coats of cement based paint white or tinted over a coat of alkali resistance primercomplete all as directed. |
| 26 | M & L for complete removal of existing surface and and applying two coats of cement based paint white or tinted over a coat of alkali resistance primer on walls etc, complete all as directed. |
| 27 | M &LPreparation of old steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as directed. |
| 28 | M&L, for preparation of old painted of wood and wooden base materials surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as directed. |
| 29 | M&L, for preparation of new wooden surface any description over 10 cm width or girth and applying two coat synthetic enamel paint over a coat pink primer complete all as directed. |
| 30 | Taking down chowkats with shutter (without taking off shutters from the frame) size not exceeding 1.5 sqm each complete all as directed. |
| 31 | Taking down chowkats with shutter (without taking off shutters from the frame) size exceeding 1.5 sqm and not exceeding 4 sqm each complete all as directed. |
| 32 | Refixing of shutter of any description exc 1 sqm and n exc 2 sqm in same opening complete all as specified and directed. (Note Total qty of shutter which is retrived from item no 31 to be refixed after the change of wooden frame to prestressed frame =22) complete all as directed. |
| 33 | S&F Powder coating of any colour aluminium frame (minimum thickness of powder coating 50 micron) for doors,windows, ventilators with one or more rebates including joining cleat fixing etc all complete as per drawings complete all as directed. |
| 34 | S&F powder coating of any colour (thickness of powder coating is not less than 50 micron) aluminium window , ventilator shutters, Partition fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised alumnium snap beading, screws etc. complete all as directed. |
| 35 | S & F 4 mm thick plain sheet glass type and glazing fixed in aluminium frame work exc 0.5 Sqm in each pane etc complete all as directed. |
| 36 | S&F stailness steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks etc complete all as directed. |
| 37 | S&F Aluminium anodised door stopper with rubber shoes of size min 150mm long complete all as directed. |
| 38 | S&F in repair Aluminium anodised door stopper with rubber shoes of size min 150mm long complete all as directed. |
| 39 | S&FAluminium anodised barrel tower bolt extruded section and fixed of size 200mm complete all as directed. |
| 40 | S&F in repair Aluminium anodised barrel tower bolt extruded section and fixed of size 200mm complete all as directed. |
| 41 | S&F for aluminium 300 mm long sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or aluminium alloy and fixed complete all as directed. |
| 42 | S&F in repair for aluminium 300 mm long sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or aluminium alloy and fixed complete all as directed. |
| 43 | S&F 300mm MS ordinary rat tail rod pattern springs , including roller and roller plate complete all as directed. |
| 44 | S&F frame work such as grills, grating etc with ends of bars shouldered and or rivetted or forged into spikes, framed guard bars, barred iron doors, ladders etc and similar wks conforming to Fe-290 Gd E-165 complete all as directed. |
| 45 | S&F 150mm long aluminium handles cast type, anodised complete all as directed. |
| 46 | S&F in repair 150mm long aluminium handles cast type, anodised complete all as directed. |
| 47 | S & F in repair brass CP bracket fancy type suitable for fixing to 20mm dia curtain rod complete all as directed. |
| 48 | S&F in repair Stainless steel tubing of 19/20 mm bore, 1.00mm wall thickness as in curtain rod complete all as directed. (For the purpose of measurement and payment running length of curtain rod only shall be considered). |
| 49 | S&F 1.25mm thick Pressed steel frames of size 125X60 mm for doors with one or more rebates including necessary fixing lugs, hinges lock strike plate,etc complete all as directed. |
| 50 | S&F 1.25mm thick pressed steel frame of size 105x60mm for doors with one or more rebate incl fixing lungs lock strike plate complete all as directed. |
| 51 | M&L PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in hold fast complete all as directed. |
| 52 | S & F 30 mm thick flush shutters solid core construction with block board core and plywood face panels, commercial type on both sides supplied and fitted to chowkats complete all as directed. |
| 53 | S&F 30 mm thick Glazed and skeleton shutter open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as directed. |
| 54 | S&Fin repair for 18 mm thick Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on both faces; fixed with screws to timber frame work and kitchen cabinet etc complete all as directed. |
| 55 | S&F door cabinet hinge - Regular-full Overlay SS bright finish fixed in modular kitchen complete all as directed. |
| 56 | S&F Extruded brass handles, fabricated type polished 150 mm in size and fixed complete all as directed. |
| 57 | S&F door magnet for kitchen cabinet omplete all as directed. |
| 58 | S&F solid PVC door frame of size 50mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS Square tube fix in opening all as shown on drawing complete all as directed. |
| 59 | S&F factory made solid panel PVC door shutter 30 mm thick style consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheets strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail and bottom rail on either side and as gap inside for top rail and bottom rail paneling of plain colour PVC sheet to be fitted in the MS frame welded/seated to the stiles and rail with suitable PVC sheet bending and jointed to gather with solvent cement supplying and fixing in the frame at site as per specification complete all as directed. |
| 60 | S & F 100 mm size Butt hinges medium weight cold rolled mild steel and fixed complete all as directed. |
| 61 | S&F mild steel cupboard shutter with frame, Godrage pattern, made out 22 guage mild steel sheet including chromium plated MS handle with proper locking arragements ( brass mortice lock, vertical type, size 65mm, 4 livers with escutcheon plates & two keys ) with and including two coats of spray painting with synthetic enamel of approved tint over a coat of red oxide primer including fixing with 6 Nos 12mm dia bolts 150mm long grouted in brick wall/ concrete including making good the disturbed surface as original complete all as directed. |
| 62 | M&L anti termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as directed. |
| 63 | M& L anti termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as directed. |
| 64 | Demolition of cement concrete reinforced as in chullah hoods , shelves, cover slab and plate form etc complete all as directed. |
| 65 | M&L reinforced cement concrete type B-1 (1:2:4) using 20mm graded stone aggregate as in slab supported on walls, shelves and similar work etcomplete all as directed. |
| 66 | M & L for mild steel TMT bars 8 to10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as directed. |
| 67 | M&L Granite (of any type) work (table rubbed and polished) of any shade 18 to 20mm thick in cooking platform, steps, windowcills, etc over and incl 15mm thick cement screed base in CM 1:4 laid and jointed with white cement slurry mixed with admixture of pigment to match the shade of the slab incl rounding of slab & demolition of old slab complete all as directed. |
| 68 | Taking up or down steel tubing and connection of 15 mm bore complete all as directed. |
| 69 | -ditto- all as per Ser item No 68 above but for 20 mm dia bore pipe complete all as directed. |
| 70 | -ditto- all as per Ser item 68 above but for 25 mm dia bore pipe complete all as directed. |
| 71 | S&F steel tubing for 15 mm bore and connection tubing in new or old position to walls, ceiling, floors etc including all fitting as socket,elbow,nipple,union etc for hot and cold water complete all as directed. |
| 72 | -Ditto- all as per Ser item 71 above but for 20 mm dia complete all as directed. |
| 73 | -Ditto- all as per Ser item 71 above but for 25 mm dia complete all as directed. |
| 74 | S&F 1000 ltr capacity Rotational moulded polyethylene water storage tank (cylindrical vertical closed top) hoisted and fixed in positions all as specified in SSR Part-I,including 20 mm dia of ball valves high pressure of PTMT with epoxy coated aluminium rod &highdensity plastic ball screwed for iron pipe and fixed including dismantling complete all as directed. |
| 75 | S & F in repair for PVC connection pipe of 15 mm dia and 45 cm long to WHB and flushing cistern complete all as directed. |
| 76 | S&F in repair 15mm dia angle stop valves cast copper alloy faney type,chromium plated complete all as directed. |
| 77 | S&F in repair for Gun-metal, globe or gate valves 20mm, with iron wheel head, screwed both ends for iron pipe etc comlete all as directed. |
| 78 | S & F in repair, 15mm bore bib taps cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified . |
| 79 | S & F in repair, 15mm bore Brass wall mixer for mixing hot and cold water cast copper alloy, chromium plated with crutch or butterfly handle with swan neck, screwed down, screwed for iron pipe or brass ferrule complete all as directed. |
| 80 | S & F in repair, 15mm bore Brass central hole basin mixer for mixing hot and cold water cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as directed. |
| 81 | S & F in repair, 15mm bore Brass sink mixer with regular spout W/M for mixing hot and cold water cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as directed. |
| 82 | S & F in repair, 15mm bore stop valve cast copper alloy, fancy type chromium plated with long shank and cup (concealed) screwed down,high pressure with crutch or butterfly handle, screwed both ends for iron pipe complete all as directed. |
| 83 | S&F in repairs for shower rose chromium plated with or without swivel joints 125 mm dia complete all as directed. |
| 84 | S&F in repair vitrious china wash basin pedestal, white flat back size 550 x 400 mm including waste, chain & plug and poreclain stopper and bracket etc. Complete including cutting for and pinning in ends of brackets or errecting bracket and 32mm dia waste fitting brass chromium plated for WHB etc;with long screwed shanks and fly nuts,flange end bedded in red lead cement including 32mm dia waiste pipe fitted complete all as directed. |
| 85 | Material and labour for vitreous china ,squatting pan Orissa pattern size 580x440mm white with integral foot rest including connection as directed including taking down old pan and making good disturbed surfaces complete all as directed. |
| 86 | S&F in repair vitreous china wash down water closet pan, pedestal pattern Pedestal pan and trap(excluding flushing cistern and flush pipe), including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc and including seat and cover for pedestal pan complete all as directed. |
| 87 | S&Fin repair health faucet (ABS body) mild steel chromimum plated sutable for 15mm dia pipe with 1.25 mtr long flaxible tube and ABS wall hook including making connections and fixed in position complete all as directed. |
| 88 | S&F in repair for 10 ltrs capacity flushing cistern PVC low level valve less, symphonic action type flushing cistern white with inlet, ball valve, float and handle including brackets and 32 mm flush pipe of polyethylene complete all as directed. |
| 89 | S&F in repair shelf 450mm long of PTMT fixed with and incl chromium plated brass screws and wooden /plastic cleats (minimum weight 300 grams) complete all as directed. |
| 90 | S&F in repair stainless steel kitchen sink with drainage board 1 mm thick including bedding in cement mortor on to dwarf wall or including fixing centilever brackets over all size 915 mm x 460mm baw/size 410 mm x 330 mm x 160 m and including 38/40mm dia waiste pipe complete all as directed. |
| 91 | S&F in repair stainless steel uternsil rack of size 24\\" X 36\\" X10\\" of approved quility and fixed in kitchen complete all as directed. |
| 92 | S&F in repairs CP towel rail, 20mm dia, D type,60cm long complete all as approved complete all as directed. |
| 93 | S&F in repair 600x450mm beveled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial ply wood and fixed to wooden ply with chromium plated brass screws and cup washers complete all as directed. |
| 94 | Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittins,heads,shoes,bends,swan-necks,etc including removing from site complete all as directed. |
| 95 | M&L for 110mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls including PVC clamps fixed to wall properly including fixing of pipe with PCC (1:2:4) complete all as directed. |
| 96 | M&L for 110mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints laid in trenches or in floors properly including fixing of pipe with PCC (1:2:4) complete all as directed. |
| 97 | M&L for 75mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls including PVC clamps fixed to wall properly including fixing of pipe with PCC (1:2:4) complete all as directed. |
| 98 | M&L for 75mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints laid in trenches or in floors properly including fixing of pipe with PCC (1:2:4) complete all as directed. |
| 99 | S&F PVC (SWR) bends 110 mm bore of any radius complete all as directed. |
| 100 | S&F PVC (SWR) bends 75 mm bore of any radius complete all as directed. |
| 101 | S&F PVC (SWR) junction single (singleT) equal or unequal 110mm bore provided with access door complete all as directed. |
| 102 | S&F PVC (SWR) junction single (singleT) equal or unequal 75mm bore provided with access door complete all as directed. |
| 103 | S&F 110 mm bore PVC (SWR) vent cowl complete all as directed. |
| 104 | S&F 75 mm dia outlet Cast iron (SWR) floor trap plain with steel grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) with solvent cement complete all as directed. |
| 105 | S&F 110mm dia PVC (SWR)WC connector with lip ring complete all as directed. |
| 106 | Demolition of cement concrete (un-reinforced) in ground floors and paving not exc 15 cm thickness (above or below GL) complete all as directed. |
| 107 | M&L PCC 1:3:6, type C-1 using 20mm graded stone aggregate, as in foundation ,filling and surface channel and drains etc complete all as directed. |
| 108 | M&L forming fair finished drain or channel, 30 cm inner girth, cement concrete ,using extra cement including forms, moulds, mitred/stopped ends finished even and smooth, using extra cement including forms moulds etc complete all as directed. |
| 109 | M & L for 75 mm thick PCC 1:3:6 type C-1 using 20mm graded stone aggregate including finished surface even & fair without using extra cement as in plinth protection including necessary form work of edge all as specified and directed. Note: 10mm wide and 75mm deep joints shall be made at 3 mtr intervel and at each corner and the same shall be filled with using bitumen 85/25 and sand in the ratio 1:3 complete all as directed. |
| 110 | Taking down complete existing treatment of roof/ parapet , Mud puska on roof /parrapet including plastering, brick tiles, stone slabs and leeping any thickness including removal etc ccomplete all as directed. |
| 111 | M&L Brushing neat cement slurry (3 Kg of cement per Sq M) mixed with water proofing liquid in the proportion,water proofing liquid, water & cement (1:4:7) or as per manufacture instructions for bonding of old concrete surface to new concrete complete all as directed. |
| 112 | M&L PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) mixed with integral waterproofing chemical compound mixed in proportion 200 millilitre per 50 Kg cement as in padding, benching,Sunken portion etc on roof surface for corecting/making proper slope on roof, etc complete all as directed. |
| 113 | M&L Rendering 10 mm thick in cement mortar 1:3 on concrete / brick surfaces with liquid water proofing compound @ 200 ml/50 kg per bag of cement or as per manufacturar instruction finished even and smooth without using extra cement over roof / sunken slab /wall complete all as directed.NOTE : water proofing liquid will be measured and paid seperately . |
| 114 | M&L for Water proofing treatment on \\"Non approachable / non accessible roof\\" surface (Horizontal & Vertical surfaces) in following sequence through manufacturer / authorized applicator of the manufacturer complete all as directed. |
| 115 | M&L for applying approved bituminous based primer conforming to IS : 3384-1995 @ 0.3kg/Sqm to be applied on top surface of prepared surface till the surface is properly impregnated complete all as directed. |
| 116 | M&L for laying APP (Atactic polypropylene Polymer Modified preffabricated membrane) water proofing membrane of weight not less than 3 kg/sqm with minimum 100mm side overlap along the length from downward to upward completely sealed with torch application/hot blown lamps complete all as directed. |
| 117 | M&L for applying two cots of bituminous based aluminium paint @ 0.3 kg/Sqm complete all as directed. |
| 118 | Supply only water proofing compound (liquid),ISI marked complete all as directed. |
| 119 | M&L for repair and rendering 10mm thick in cm 1:3 on chajjas not exceeding 60cm width after removing cracked plaster and concrete including cleaning of viisible reinforcement and treating with cement slurry also necessary repair to cracked concrete if any with cement concrete 1:2:4 Type B-0 using 12.5mm graded aggregate including necessary scafolding work for double/single storey bldgs complete all as directed. |
| 120 | M&L machine cut kota stone slab flooring 18-20mm thick over & including 20mm screed base in CM 1: 4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as directed. |
| 121 | M&L machine cut kota stone slab flooring 18-20 mm thick over & including 20mm screed base in CM 1: 4 as in step tread in one piece in one step, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as directed. |
| 122 | M&L for 16-18mm thick white Marble stone flooring as in border,etc at kota stone flooring over 20mm screed base in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as directed. |
| 123 | M&L machine cut Kota stone 18-20 mm thick in riser of steps,skirting over 15mm thick cement plaster in cm (1:4) laid and jointed with gray cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as directed. |
| 124 | Supply and fix in repairs bath room mirror cabinet PVC of size 450mmx600mm fancy type complete all as directed. |
| 125 | M & L for chipping removing carefully concrete work by low impact hammer, breakar without damaging the structure & cleaning and disposal of debries out side the premises etc complete all as directed. Note:- Hard concrete should not be removed by force. |
| 126 | M&L for Clean existing reinforcement with wire/ rotary wire brush making the surfaces free from loose material dirt etc complete, Applying two coats of alkaline rust converting primer FEOVERT of Krishna conchem or Dr. Fixit equivalent confirming to ASTM-B-117 on the rebars, including cleaning the reinforcement, wire brushing to remove loose rust spalls, with time interval of 6 hour between the coats and applying protective coating IPNET-RB complete all as directed. |
| 127 | M&L Carry out application of 'Bi-polar migratory corrosion inhibitor' EPCO-KP-100 or equivalent on concrete surface.complete all as directed. |
| 128 | M&L for Providing and applying structural grade EPIBOND-21-LP prior to application of any type of mortar plaster conferming to ASTM-C-882-91 (Arizona Slant Shear Test) to ensure bond between old concrete and new concrete complete all as directed. |
| 129 | M&L for Building up the profile of structural members by using latex additives(MONOBOND) modified air cured mortar system (Polymer modified mortar) (1:5:15 =1-MONOBOND, 5-Cement, 15-Sand) in damaged areas in 20mm thickness including leveling profiling etc complete all as directed. |
| 130 | M&L for Building up the profile of structural members by using latex additives(MONOBOND) modified air cured mortar system (Polymer modified mortar) (1:5:15 =1-MONOBOND, 5-Cement, 15-Sand) in damaged areas in 40mm thickness in two layers including leveling profiling etc complete all as directed. |
| 131 | M&L for replacement of steel reinforcement with TMT bars of appropriate size where 20% of cross section is reduced including dismantling of rusted steel including application of rust converter FEOVERT and applying protective coating IPNET-RB complete all as directed. |
| 132 | Dismantling timber scantling in fillet,rails,posts,rafters,purlin,Etc under 40sq.cm in section etc complete all as directed. |
| 133 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete incl fixtures and fittings suze as swithes, ceiling rose, pendant, regulator, ssockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (Credit for above items should be as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as directed. |
| 134 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as directed. |
| 135 | Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as directed. |
| 136 | Taking down existing geyser of any capacity after disconnecting all necessary electrical and water supply connections and deposit to MES store yard of AGE E/M complete all as directed. |
| 137 | Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M complete all as directed. |
| 138 | S & F Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as directed. |
| 139 | S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings LED bulb PAG series B-22 base complete all as directed. |
| 140 | S & F for Highly efficient LED Bulbs, 12 W, used as a ready replacement for existing GLS/CFL direct fit lamp,in B-22 cap of complete all as directed. |
| 141 | S&F LED Tube light fitting 1x18/20 Watt surface and wall mounted LED batten, PVC housing with polycarbonate diffuser & integrated electronic driver complete with all accessories internally prewired and incl connecting up three core single wire complete all as directed. |
| 142 | S & F LED 10 watts batten aluminium extruded with decorative end caps complete all as directed. |
| 143 | S & F Decorative wall mounted luminaire made out of polycarbonate with unbreakable globe suitable for LED bulb and provosion of LED bulb 10 watts complete all as directed. |
| 144 | S & F Energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired with warranty option of 5 years from date of installation and necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb complete all as directed. |
| 145 | S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25/35 watts with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed. |
| 146 | S&F of double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts suitable amps rated busbar 8 way complete all as directed. |
| 147 | S&F for Distribution board (DB) made out of sheet metal enclosure (CRCA sheet) dust and vermin proof TPN 4 way IP 43 (double door) with 200 Amps rated copper bus bar neutral bar ,earth bar ,triple pole and neutral 415volts ,flush to wall including taking down carefully existing UNSV main switches, DBS along with MCBs complete all as directed. |
| 148 | M&L for MCB single pole,6 to 32 Amp 240 volt B curve 10 KA, IP 20 transparent lebel holder fully insulated safety shutters suitable for cable up to 35Sqmm cross sectional area complete including suitable size copper Lugs complete all as directed. |
| 149 | S&F Miniature circuit breakers ISI marked 240 Volt, 50 Hz, double pole 40 Amps, breaking capacity 10 KA complete all as directed. |
| 150 | M&L for earthing complete with galvanised steel earth plate electrode 600 x 600x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connecting to main switch or switch board complete and incl PCC masonry pit of 300x300x300mm interier diamentions in PCC 1:2:4 type B1 RCC cover with GI frame, charcoal dust and common salt 15cm in layers all round the earth plate, 20mm dia GI watering pipe, a funnel with wire mesh should be provided on top of watering pipe complete all as electric plate No 3of SSR 2009 including testing after completion complete all as directed. |
| 151 | S & F in repair MCB,TPN 4 pole, 415 V, fixed type, 100 Amps with breaking capacity 25 kA, duly ISI marked, complete all as directed. |
| 152 | S & F in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as directed. |
| 153 | S & F PVC non-metallic rigid conduit ISI marked heavy duty white/ Ivory colour and its accessories heavy duty ISI marked of size 20 mm dia for LAN, telephone and TV connections including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as directed. |
| 154 | S & F energy efficient exhaust fan of 230/300 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base including writting the MES Number with synthetic enamel paint compelte all as directed. (Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be included in overall rate quoted). |
| 155 | Labour only for refixing the celing fan/ Exhaust fan obtained from taking down with replacement of unsv 3 core PVC insulated PVC sheated 3 core multistranded copper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal including over hauling the fan, painting of ceiling fans complete with two coats synthetic enamel paint by spraying including filling cavities with filler after cleaning all dust etc and writting the MES Number with synthetic enamel paint complete all as directed. |
| 156 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified for the following :- Make - Plasa/ Havells/ Polycab/ Finolex/ KEI |
| 157 | One light point controlled by one, one way switch 5 Amps |
| 158 | One fan point controlled by one, one way switch 5 Amps and regulator |
| 159 | One light point controlled by one, two way switch 5 Amps |
| 160 | One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board |
| 161 | One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. |
| 162 | One bell point controlled by one, bell switch 5 Amps |
| 163 | Description all as per item No 153 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly complete all as directed. Make - Plasa/ Havells/ Polycab/ Finolex/ KEI |
| 164 | Description all as per item No. 154 here in before but using 4.0 sq mm single core copper conductor FRLSH cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 4.0 sq mm PVC insulated copper conductor FRLSH cable as earth continuity conductor along with wiring and connecting to the common eath dolly complete all as directed. (for AC Point) Make - Plasa/ Havells/ Polycab/ Finolex/ KEI |
| 165 | S & F Modular Switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as directed. |
| 166 | S & F Modular Switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as directed. |
| 167 | S & F Modular Switch piano flush type, single pole, two way, and 5/6 Amp single module complete all as directed. |
| 168 | S & F Modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as directed. |
| 169 | S & F Modular Socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as directed. |
| 170 | S & F modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as directed. |
| 171 | S & F Bell push modular 6 Amps single module complete all as directed. |
| 172 | S & F Modular type TV Socket out let complete all as directed. |
| 173 | M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc two runs of PVC insulated with 6 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as directed. Note:- Four runs of 6 sqmm cable, two runs of 6 sqmm cable and one run of PVC conduit will be measured as one unit complete all as directed. |
| 174 | Labour only for fixing KWH meter single phase of any capacity including all necessary electrical connections complete all as directed. |
| 175 | Labour only for Re-fixing geyser of any capacity including all necessary electrical connections obtained from item No 153 above complete all as directed. |
| 176 | S&F in replacement of water heater storage capacity 25 ltrs, Single phase, 240 Volts, Colour Grey with auto cutoff and ajustable temparture incluind connecting with its and grouting complete all as directed. S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998 Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail