|
| 1 | SCHEDULE 'A' PART-I : BOQ OF WORKS FOR B/R WORKS. |
| 2 | Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), ncluding cleaning, removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed. |
| 3 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed. |
| 4 | Dismantaling of brickwork or stone/ boulder masonry, including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles built in cement mortar or cement lime mortar of any description, complete all as specified and as directed. |
| 5 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc, complete all as specified and as directed. |
| 6 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and as directed. |
| 7 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets, complete all as specified and as directed. |
| 8 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and as directed. |
| 9 | Taking up or down steel tubing of 15mm bore pipe and connections, including cleaning for re-fixing or removal to store, complete all as specified and as directed. |
| 10 | Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exceeding 4.0 Sqm each, complete all as specified and as directed. |
| 11 | Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sqm each, complete all as specified and as directed. |
| 12 | Taking down shutters of any descriptions area exceeding 1.00 Sqm but not exceeding 2.00 Sqm, complete all as specified and directed. |
| 13 | Taking down PVC pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories, complete all as specified and as directed. |
| 14 | Non-skid, coloured, ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.18 Per Square Metre but not exceeding 0.38 Per Square Metre, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6, complete all as specified and as directed. |
| 15 | Vitrified Ceramic tiles of light shade, 10mm thick (square/ rectangular) polished, non-skid, area of each tiles not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6, complete all as specified and as directed. |
| 16 | Plain cement concrete M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation, complete all as specified and as directed. |
| 17 | Vitrified Ceramic tiles of light shade, 10mm thick (square/ rectangular) polished, non-skid, area of each tiles not exceeding 0.36 Sqm , set and fixing in vertical surfaces/ skirting/ dado or any other vertical surfaces and pointed in white or coloured cement to match and including rendering of 10mm thick in cement mortar 1:4 as backing of tiles, complete all as specified and as directed. |
| 18 | Glazed ceramic coloored tiles in vertical surface/ dado, size 300x200x6/7mm, 300x450x6/7mm, 350x250x6/7mm, or 450x350x6/7mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match, the shade/ colour of tiles including rendering of 10mm thick in cement mortar 1:4 as backing of tiles, complete all as specified and as directed. |
| 19 | Plain cement concrete M-15(1:2:4), type B-1, (using 20mm graded crushed stone aggregate), nominal mix, as in cills, steps; plinth courses, string courses, lacing courses, copings, kneelers, apex stones, bed plates, including necessary form work, complete all as specified and as directed |
| 20 | Plain cement concrete M-15(1:2:4), type B-0 (using 12.50mm graded crushed stone aggregate), nominal mix, 25mm thick, as in floors, finished even and smooth without using extra cement, complete all as specified and as directed. |
| 21 | Pre-cast cement concrete block masonry M-10(1:3:6), type C-1 (using 20mm graded crushed stone aggregate) with solid blocks, exceeding 10cm in width and incluing setting in cement mortar 1:6, complete all as specified and as directed. |
| 22 | Rendering 15mm thick on fair faces of on brick work or concrete surfaces, in cement mortar 1:4, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed. |
| 23 | Preparation of new plastered surfaces of walls and applying two coats of cement paint over one coat of priming plastered and other surfaces with alkali resistant priming paint, complete all as specified and as directed. |
| 24 | Rendering 15mm thick on fair faces of on brick work or concrete surfaces, in cement mortar 1:6, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed. |
| 25 | Providing and applying plaster of paris putty of 2.0mm thickness over plastered surface to prepare the surface even and smooth before applying any paint or oil emulsion, complete all as specified and as directed. |
| 26 | Preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over one coat of chalk whiting, preparatory to distempering, complete all as specified and as directed. |
| 27 | Plain, solid, straight chowkats and frames, in second class hardwood, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed, complete all as specified and as directed. |
| 28 | Flush shutters, 30mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete al as specified and as directed. |
| 29 | Glazed and skeleton shutters in second class hardwood, 35mm thick, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats, complete all as specified and as directed. |
| 30 | Solid PVC Door Frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tube, supplying and fixing in opening as per specification and drawing, including making good to disturbed surface of walls, complete all as specified and as directed. |
| 31 | Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of mild steel tubes for top and bottom rails. Mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of plain colour PVC sheet to be fitted in the mild steel frame welded/ sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site as per specification and drawing in SSR, complete all as specified and as directed. |
| 32 | Powder coated (minimum thickness of powder coating 50 micron), anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified and as directed. |
| 33 | Prelaminated particle board, 12mm thick, interior grade, prelaminated both sides with decorative choice laminations, fixed with screws to timber frame work, complete all as specified and as directed. |
| 34 | Sheet glass, 4.80mm thick, tinted, ordinary quality and glazing with oil putty in square exceeding 0.50 Sqm in each pane, in square or any size, complete all as specified and as directed. |
| 35 | Butt hinges, size 100mm, medium weight, cold rolled stainless steel, and fixed, complete all as specified and as directed. |
| 36 | Butt hinges, size 100mm, medium weight, cold rolled mild steel, and fixed, complete all as specified and as directed. |
| 37 | Aluminium anodised, barrel tower bolts of extruded Section, size 150mm long and fixed, complete all as specified and as directed. |
| 38 | Extruded aluminium alloy handles, fabricated type, anodised, size 150mm, complete all as specified and as directed. |
| 39 | Aluminium alloy, anodised, sliding door bolt, size 250mm, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and as directed. |
| 40 | Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and as directed. |
| 41 | Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, fixed in repairs, complete all as specified and as directed. |
| 42 | Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10cm width or girth including and applying two coats of synthetic enamel paint over one coat of zinc chrome/ red oxide primer, complete all as specified and as directed. |
| 43 | Preparation of new or previously untreated wood or wooden surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and as directed. |
| 44 | Anodised aluminium snap grid frame work for false ceiling, powder coated, comprising of aluminium Tee (weight of section not less than 280 gms/mtr) and aluminium angle (weight of section not less than 280 gms/mtr), grid size 605x605mm, including Hangers 6.0mm dia, galvanised iron (upto1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of galvanised iron flat 40x3 mm size 60mm long and expansion hold fasteners 12.50mm dia, 40mm long, complete all as specified and as directed. |
| 45 | Providing and fixing everest board 4.0mm thick, designer, in ceiling fixed as per manufacturer’s instructions, grid size 595x595mm, for false ceiling all as specified,complete all as specified and as directed. |
| 46 | PVC sheet fillet 5mm thick of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed. |
| 47 | Solid PVC Wall Lining consisting of 5.0mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing. |
| 48 | Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed. |
| 49 | Plain, galvanised, mild steel sheeting, 0.80mm thick, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275, complete all as specified and as directed. |
| 50 | Galvanised, corrugated mild steel sheeting 0.63mm thick, with two corrugations side lap, fixed with L-type or J-type or cranked hook bolts in lieu of screws, in roofs, walls etc. with grade of zinc coating 275, complete all as specified and as directed. |
| 51 | Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 52 | Fibre glass reinforced translucent corrugated sheet 3.0 mm thickness with two corrugation side lap fixed with L or J type or cranked hook bolt in roof walls , complete all as specified and as directed. |
| 53 | Curtain rod, 20mm dia, mild steel, fancy type, any colour coated or chromium plated with fixing and inlcuing end knobs, fixing brackets, stops, round rings to hold the curtain, fixing with wall plugs and screws, complete all as specified and as directed. |
| 54 | Rotational moulded polyethylene water storage tanks of 1000 liters capacity, (cylindrical vertical with closed top) with lid, hoisted and fixed in position all as specified in SSR Part-I including ball valves high pressure of PTMT with epoxy coated aluminium rod and highdensity plastic ball screwed for iron pipe and fixed for 20mm bore pipe, fixing in repairs, complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 55 | Rotational moulded polyethylene water storage tanks of 1000 liters capacity, (cylindrical vertical with closed top) with lid, hoisted and fixed in position all as specified in SSR Part-I including ball valves high pressure of PTMT with epoxy coated aluminium rod and highdensity plastic ball screwed for iron pipe and fixed for 20mm bore pipe, fixing in repairs, complete all as specified and as directed. Please Enable Macros to View BoQ information |