| 1 | M&L for dismantling asbestos cement (corrugated semi corrugated etc.) sheet in roof covering/ fibre sheets etc complete all as specified and directed. |
| 2 | Dismantling timber Scantling framed work in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and as directed. |
| 3 | Taking down chowkats or frames with shutters (without taking off shutters from frames) of size exceeding 1.5 sqm and not exc 4.00 sqm each complete all as specified and as directed |
| 4 | Taking down chowkats or frames with shutters (without taking off shutters from frames) of size not exceeding 1.5 Sqms each complete all as specified and as directed |
| 5 | Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and as directed. |
| 6 | Dismantling floor hearth or wall tiling including cement mortar bedding ( but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 7 | Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete incl removal of demolished material to a distance as specified. |
| 8 | Demolition of cement concrete of any description and in any position not otherwise specifically provided in roof padding concrete etc complete incl removal of demolished material to a distance as specified. |
| 9 | Material and labour for 20mm thick granite slab (of any size) machine cut, jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone duly grinding and polishing laid over and including 15mm thick screed bed of 1:4 in steps, jambs, pillars, window cills, cooking platforms and like incl taking down cill of any description and complete all as specified and as directed. |
| 10 | Rounding of / moulding to edges (half round) of stone of any description including rubbing and polishing (Granite finish), complete all as specified. |
| 11 | Taking down cement plaster of any description and thickness on brick walls including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed |
| 12 | Supply and fix rolled mild steel sections of Fe 410-W (GDE E-250) QUALITY “A” frame work as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates complete all as specified and as directed. |
| 13 | Supply and fix pre-painted galvalume aluminium zinc coating galvanised based Corrugaed steel sheet 0.50mm thick, AZ-150 of approved colour sheet of 0.50 mm thick having tensile strength of 550 Mpa as roof covering/cladding to wall fixed with self tapping (SD) screws complete all as specified and as directed. |
| 14 | Supply and fix pre-painted galvalume aluminium zinc coating galvanised based profiled/plain steel sheet 0.50mm thick, AZ-150 of approved colour sheet of 0.50 mm thick having tensile strength of 550 Mpa as ridge, gutters fixed with self tapping (SD) screws complete all as specified and as directed |
| 15 | Supply and fix hand rails, half rounded or other stock section or core for wooden hand rail straight portion, drilled and counter sunk for balusters, nosing to steps including embeding in concrete and screwing etc wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets (for securing wire mesh etc) including all necessary drilling or riveting etc and similar work confirming to Fe-410-0 of Fe-310-0 of Gde E-165 complete all as specified and as directed. |
| 16 | Material and labour for plain cement concrete 1:2:4, type B1 using 20 mm graded stone aggregate as in bed block, coping, roof kerbs, bands etc including necessary form work complete all as specified and as directed |
| 17 | M&L for preparation of new surfaces of steel, of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 18 | M&L for preparation of new surfaces of steel, of any description, not otherwise described, n.exc 10 cm in width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 19 | M&L for preparation of old surfaces of steel, of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 20 | Material and labour for Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, inbuilt in cement mortar 1:6 complete all as specified and as directed. |
| 21 | S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with clips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre over the grid providing 4mm thick HPSC pre primed self designer texture non asbestos fibre cement building board fixed to frames etc, including taking down old ceiling of any description, complete all as specified and and as directed. |
| 22 | Refixing of any type of ceilling frame work without taking down the existing frame work of any description including tightning and replacing of damaged hanging GI wires and getting true level complete all as specified and and as directed. |
| 23 | S&F in repairs 4mm thick HPSC pre primed self designer texture non asbestos fibre cement building board fixed to false ceiling grid system of size 600 x 600mm frames etc complete all as specified and as directed. |
| 24 | Taking down and Re-fixing only in repairs 4mm thick HPSC pre primed self designer texture non asbestos fibre cement building board fixed to false ceiling grid system of size 600 x 600mm frames etc complete all as specified and as directed. |
| 25 | Material and labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed |
| 26 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces in two coats (10 + 5 mm), both coat mixed with integral water proofing compound ISI Marked @ 2% by the weight of cement and finishing the surface even and fair complete all as specified and directed Note - WPC shall be measured and paid separately. |
| 27 | Supply only water proofing compound of ISI marked complete all as specified and as directed. |
| 28 | M&L for PCC 1:2:4 type B1 (using 20mm graded aggregate) in copings, kerbs, channels, water through and the like including weathering, slightly rounded or chamfered angles and throating as directed chamfered necessary for work. |
| 29 | M&L 20-25 mm thick machine cut Polished kota stone as inflooring laying down and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over bedding layer of 15mm thick in CM 1:6 complete all as specified and directed. |
| 30 | M&L 20-25 mm thick machine cut Polished kota stone as in skirting / riser of staircase laying down and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over backing coat of 15mm thick in CM 1:4 complete all as specified and as directed. |
| 31 | M&L Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over backing coat of 15mm thick in CM 1:4 complete all as specified and as directed. |
| 32 | M&L Glazed coloured ceramic tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete over backing coat of 15mm thick in CM 1:4 complete all as specified and as directed. |
| 33 | M&L for designer rubber moulded chequered cement concrete tiles with mixture of grey pigment cement and pigment in equal porportions with pigments of size 200x 200xx25mm ,300 x 300 x 22mm or 250 x 250 x 22mm thick and set and pointed in neat cement slurry in floors over a screed bed or bedding layier in CM 1:6, 15mm thick for laying floor finishes etc complete all as specified and as directed. |
| 34 | M&L for Cement concrete in foundations, filling and mass concrete Type D2 1:4:8 using 40mm graded aggregate.etc complete all as specified and as directed. |
| 35 | Supply and fix steel windows (fly proof and glazed shutter) made with galvanised steel colour coated/ powder coated ( Base steel as per IS 513 'D', galvanised as per IS 277 with zinc of 120gm/sqm) with total coating thickness of 0.60mm. ( outside for glazing and inside gauged shutter) Sections for frame should be of 72mmx55mm, section for mullian should be 72mm x 50mm section for shutter frame should be 47mmx 20mm,and section for fixing glass bead should be 12mm x 12mm and section for fly mesh shutter frame should be 40mm x 20mm mesh fixing should be of 18mm x 0.6mm. Stainless steel wire mesh of 0.45mm dia and ave width of aperture 1.4mm shall be used for fly proofing . 4mm thick plain sheet glass to be used for glazing of glazed shutters including 10mm powder coated square saftey grills, locking arrangement and all necessery accessories etc, completed all as specified and directed. |
| 36 | S&F 125 x 60 mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified, supplied and fixed. |
| 37 | S&F 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides. complete all as directed and specified. |
| 38 | S&F 35 mm 2nd class hard wood factory made glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc (without sash bars) edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc size of member of shutter as specified in SSR Part-I section 8 clause 8.24(a) etc completed all as specified and directed. |
| 39 | Supply and fix butt hinges of 100mm size extruded aluminium alloy with galvanised mild steel hinge pin, anodised, type C-21 complete all as specified and as directed |
| 40 | Cutting holes in brick wall exc. half brick but not exc. one brick built in cement mortor for inserting hold fast and making good the disturbed portion in cement mortor 1:3 depth of embeded portion exc half brick & N.exc one brick. |
| 41 | S&F of Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 |
| 42 | Treating small articles such as hold fasts, ends of posts, backs of chowkats etc area n.exc 0.10Sqm each with coal tar black paint complete all as specified and as directed. |
| 43 | M&L for Providing, cement concrete Type C1 1:3:6 (20mm graded aggregate) in steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 44 | M & L applying new wood surface two coats of synthetic enamel paint over a coat of prink primer on wood or wood based material over 10 cm width or girth including preparation of new wood surface |
| 45 | S&F for Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc all as specified and directed. |
| 46 | S&F 150 mm extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 47 | S&F 150mm aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 48 | S&F 300 Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy all as specified. |
| 49 | M&L 75 mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) in plinth protection laid in alternative bays finished even and smooth without using extra cement including making 10 mm wide grooves to full depth at 3 m interval and at every change of direction and filling the grooves with mixture of bitumen and sand mixed in the ratio of 1:3 by weight and top 10 mm depth sealed with sealing compound grade ‘A’ complete all as complete all as specified and as directed. |
| 50 | S&F in repairs 4 dia Plain mild steel wire, galvanised class 3, in detached work such as for mosquito nets and fixing to straining bolts, hooks, eyes, etc. including securing with and provision of galvanised iron tying wire, galvanised iron staples or steel pins, etc. as directed (each line of wire to be measured) including making necessary anchorage arrangements in wall and complete all as specified. |
| 51 | M&L for complete removal of existing treatment on wall surfaces and applying two coats of oil bound distemper over a coat of primer over a coat of 3mm thick birla care wall putty etc all as specified and as directed. |
| 52 | M & L for preparing newly plasterd wall surfaces of walls and applying two coats of distemper oil emulsion over 3 mm thick wall care putty and a coat of primer etc complete all as specified and as directed. |
| 53 | M & L for preparing old trated surfaces of walls and applying two coats of distemper oil emulsion and complete all as specified and as directed. |
| 54 | M&L for complete removal of existing finishes and applying two coats of cement based paint including preparation of surfaces etc all as specified and as directed. |
| 55 | M & L for preparing newly plasterd wall surfaces of walls and applying two coats of cementbase paint etc complete all as specified and as directed. |
| 56 | M & L for preparing old trated surfaces of walls and applying two coats of cementbase paint etc complete all as specified and as directed. |
| 57 | Demolition of brickwork or stone/boulder masonry, built in cement mortar with all quoins, arches, pillars, etc but excluding ashlar facings, dressed stone work and precast concrete articles including disposal of the rubbish out off the premises complete all as specified and as directed. |
| 58 | Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr depth for laying cable and getting out in soft/loose soil all as specified and directed. |
| 59 | Returning, filling in soil including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick all as specified and directed |
| 60 | Removing surplus soil to a distance not exceeding 50 Mtr and deposited at a level not exceeding 1.5 mtr above from the starting point all as specified |
| 61 | Supplying, laying, jointing, testing and commissioning 1100 volts grade, LT XLPE insulated, PVC sheathed as per IS-7098 (Part-I), 1988 galvanized steel strip or wire armoured, heavy duty, electric cables, with multistranded aluminium conductor laid in trenches/ passing through pipe/duct/road crossing or fixed on poles, walls with suitable size clamps made out of mild steel flat iron including jointing material such as crimping type lugs, brass cable glands, heavy duty double compression type etc., including taking down unserviceable cable complete all as specified and directed. for the following sizesNote : Earthwork Excavation, sand cushioning GI pipe and cable protection will be measured and paid separately. |
| 62 | All as per item No. 61 above for 3.5 core 95 Sqmm |
| 63 | All as per item No. 61 above for 3.5 core 50 Sqmm |
| 64 | All as per item No. 61 above for 4 core 35 Sqmm |
| 65 | Supply and laying in trenches of 80 mm dia DWC HDPE pipe, Heavy Duty, conforming to IS 14930 Part 2, made of HDPE, with corrugated outer wall and smooth inner bore, suitable for passing 1.1 kV, 3.5C x 50 to 95 sqmm XLPE cable, including cost of couplers, jointing accessories, end caps, and laying as per site requirement & engineer-in-charge direction. Make SFMC, Reliance, Supereme. Complement all as specified and directed by Engr-in-Charge |
| 66 | Supply and laying in trenches of 80 mm dia DWC HDPE pipe, Heavy Duty, conforming to IS 14930 Part 2, made of HDPE, with corrugated outer wall and smooth inner bore, suitable for passing 1.1 kV, 4C x 35 sqmm XLPE cable, including cost of couplers, jointing accessories, end caps, and laying as per site requirement engineer-in-charge direction. Make SFMC, Reliance, Supereme. Complete all as specified and directed by Engr-in-Charge |
| 67 | Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine suitable for 0.4 mpa working pressure complete all as specified and as directed by Eng-in-chagre. |
| 68 | S&Fin repairs 50mm dia GI pipe light grade fixed to walls/poles or laid in trenches, road crossing etc., for protection of underground cable/earth strip including sealing ends with hessian cloth impregnated with bituminous compound in ground and with teak wood bushes for ends fixed on walls/poles complete all as specified and directed. |
| 69 | S&Fin repairs 80mm dia GI pipe light grade fixed to walls/poles or laid in trenches, road crossing etc., for protection of underground cable/earth strip including sealing ends with hessian cloth impregnated with bituminous compound in ground and with teak wood bushes for ends fixed on walls/poles complete all as specified and directed. |
| 70 | Supply, installing, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, vermin proof, cubical type, platform mounted, suitable for 415 volts, 3 phase 4 wire 50 Hz AC supply system all as specified and directed, with necessary bus bar arrangement with insulated bus bar 600 Amps rating , 4 strips, the panel should be dust proof, IP 54 class protection and made out of 3.15mm thick CRCA mild steel sheet with 40x40x5mm angle iron frame with necessary earth work excavation, hinged doors, front and rear opening and locking arrangement and duly powder coated on the out side and inside, cable glands and lugs for incomming and out going cable etc, independent chamber to accommodate complete all as specified and directed including following accessories Incoming: (a) MCCB 4 pole adjustable type, 200 Amp, 415 Volts 16KA - 01 NoOutgoing:(b) MCCB 4 pole adjustable type, 63 Amp, 415 Volts 16 KA - 5 No (c)Indicating lamps (set 03 Nos)- 01set (R,Y&B)(d) Digital panel mounted Voltmeter and ammeter flush type of size 96 X 96 mm three phase(e) Panel wiring with suitable size PVC insulated heavy duty 1100 volts grade single core cable with copper conductor multistranded with cable end termination lugs. |
| 71 | Supply, installing, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, vermin proof, cubical type, platform mounted, suitable for 415 volts, 3 phase 4 wire 50 Hz AC supply system all as specified and directed, with necessary bus bar arrangement with insulated bus bar 400 Amps rating , 4 strips, the panel should be dust proof, IP 54 class protection and made out of 3.15mm thick CRCA mild steel sheet with 40x40x5mm angle iron frame with necessary earth work excavation, hinged doors, front and rear opening and locking arrangement and duly powder coated on the out side and inside, cable glands and lugs for incomming and out going cable etc, independent chamber to accommodate complete all as specified and directed including following accessories Incoming: (a) MCCB 4 pole adjustable type, 125 Amp, 415 Volts 25KA - 01 NoOutgoing:(b) MCCB 4 pole adjustable type, 63 Amp, 415 Volts 16 KA - 4 No (c)Indicating lamps (set 03 Nos)- 01 set (R,Y & B)(d)Digital panel mounted Voltmeter and ammeter flush type of size 96 X 96 mm three phase(e)Panel wiring with suitable size PVC insulated heavy duty 1100 volts grade single core cable with copper conductor multistranded with cable end termination lugs. |
| 72 | M & L earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth strip 25 x 4mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note:- Item of earthing includes cost of 7.5m long galvanised iron earth strip of 25 x 4mm size and protection pipe of 40mm bore GI medium grade. |
| 73 | Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified. |
| 74 | Taking down old unservicieble existing submain wiring of any size and type |
| 75 | Taking down old unservicieble existing DB's any size and type |
| 76 | Material and labour for concealed point wiring complete with stranded copper conductor cables in concealed non-metallic PVC conduit 1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade FRLS conforming to IS - 694 multistranded drawn including conduit with new sunk type pressed steel terminal boxes suitable for MODULAR switches including fixing/grouting sunken/ surface as per site requirement covered with suitable modular white cover plate for suitable size for mounting of MODULAR switches, regulators and drawing continuous earth wire with one run of 1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade FRLS conforming to IS - 694 multistranded copper conductor as earth wire and connecting to common earth dolly and making good the disturbed wall surfaces to match with the existing surfaces complete all as specified and as directed for the following :- Note: Moduar cover plate with frame and modular metal flux box included in the rate quoted. |
| 77 | (a) One light point controlled by one, one way switch 5 amps, SP |
| 78 | (b) One Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator |
| 79 | (c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board . |
| 80 | (d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 81 | Supply and fix in replacement of MODULAR switch 1 way 6 A, 1 Module capacity 230 volts complete all as specified and as directed. |
| 82 | Supply and fix MODULAR socket 5 pin 6 amps 2 MODULE, 230 Volts complete all as specified and directed. |
| 83 | S & F in replacement of Modular ceiling fan regulator 5 stepped type heavy duty suitable to work on 230 volts complete all as specified, 2 Module |
| 84 | S & F in replacement of ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified. |
| 85 | Supply and fix in replacement of wall mounted LED batten with extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver 1 x 20w, 230 volts,120 lumen/watt, 50,000 burning hrs, THD<10%, bipin holders, DIFFUSED TYPE connector block internally prewired etc with 2 Nos PVC round blocks for mounting arrangements including all accessories with new 3 core multi stranded copper conductor of size 23/0.193 from ceiling rose to fitting and including LED Tube 20W complete all as specified and as directed. |
| 86 | Supply and fixing LED luminaire 600 mm x 600 mm,36 watt, 220 V AC,150 lumen/watt, 50,000 burning hrs, UGR<19 recessed /surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. |
| 87 | Supply and fix of LED security light luminaire fitting of 1x35 watts with deep drawn housing including all accessories with suitable 40 mm dia GI bracket 0.60 Mtr length fixed on wall with 50x6 mm flat iron, clamps, nuts and bolts complete all as sepcified and as directed. |
| 88 | S&F sheet metal enclosure vertical type MCCB DB TPN 4 way double door with suitable rated bus bar 415 volts suitable for MCCB TPN as incomer with suitable rated copper bus bar with neutral link including provision for 100 Amps MCCB 25KA TPN as incomer and SP/TP MCBs as outgoing and total number of modules equal to MCCB TPN + 12 with blanking plates and fixed flush to wall and making good the disturbed surfaces etc, complete all ass specified and as directed. Note: MCB SP/TPN will be measured and paid seperately. |
| 89 | S & F in repair MCCB TPN 100A 25KA complete all as specified and as directed Make -Indoasian |
| 90 | S & F sheet metal enclosure MCB DB SPN 12 way with 200 amps rated bus bar 240 volts double door with magnetic locking system complete all as specified . |
| 91 | S & F in replacement of MCB SP 6 to 32 Amps 240 volts for fixing on MCB/MCCB DB's all as specified. |
| 92 | S & F MCB SPN 40 to 63 Amps 240 volts for fixing on MCB DB's all as specified. |
| 93 | Material and labour for earthing with galvanized mild steel earth plate electrode 60 centimetre x 60 centimetre x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below ground level, the top edge of the earth plate at a depth of not less than 1.5 metres below ground level connected to galvanized iron earth wire of 4 mm dia by means of bolts, nuts and washers made out of GI / steel earth wire protected by GI light grade pipe 15 mm bore, 20mm dia light grade galvanised iron pipe with funnel wire mesh for watering and connecting to main switch board / control board all s shown in electrical plate of SSR Pt - I connected to earthing test point and including testing on completion complete all as specified and as directed.NOTE: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 type C1 by using 20 mm graded aggregate in pit, 50 mm thick reinforced cement concrete 1:2:4 type B1 using 20 mm graded aggregate cover duly reinforced with 8 mm dia TMT bars @ 100mm centre to centre both ways, galvanised iron funnel with watering pipe, wire mesh, complete. |
| 94 | Material and labour for sub main wiring with two runs of single core FRLS PVC multistranded stranded unsheathed copper conductor cable of size 6 square mm and drawing through concealed PVC conduit of 25mm dia with accessories in wall/roof along with one run of 6 square mm FRLS PVC insulated unsheathed multi stranded 1100 volts grade with copper conductor cable as earth continuity conductor connected to earth and earth dolly, connecting to main board making good the disturbed wall surfaces to match with the surroundings complete all as specified and directed.Note: 3 runs of 6 Square mm cable and 1 run of PVC conduit with accessories shall be measured as 1 unit of running metre. |
| 95 | Taking down ceiling fans 1200/1400mm sweep, exhaust fan 200/450 mm sweep and wall mounted fan, repairing/cleaning of dust properly cleaning, greasing& overhualing of bearings including refixing and connecting up all as directed. |
| 96 | M & L for cutting chases, pining to making good to facing where ever required and pointing in cement motor 1:3 to ends or edges of endings, steps, cills etc and cutting chases for concealed wiring making good and cutting not exceeding10 cm grith complete all as specified and as directed. Please Enable Macros to View BoQ information |