| 1 | Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out in soft/loose soil complete all as specified and as directed. |
| 2 | Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out in hard/dense soil complete all as specified and as directed. |
| 3 | Demolition of brick/block or stone/boulder masonry walling built in cement mortar including all quoins arches pillars etc and removal unserviceable materials, debris, rubbish to out side MD land complete all as specified and as directed. |
| 4 | Removing building materials etc. (other than spoil payable under items 03028 to 03031 in Section-3—Earthwork) to a distance of 100m or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and directed. |
| 5 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. |
| 6 | Removal of excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 7 | Disconnecting of existing overhead water tanks any type of capacity exc 500 Ltr but n exc 1000 ltr setting aside (or lowering if required) for repairing, cleaning etc and hoisting and reconnecting and refixing in position complete all as specified and directed. |
| 8 | Demolition of cement concrete in roof padding damaged/loose cement concrete / brick tiles from roof/ terrace to a depth of average 50mm including dismantling of existing treatment with APP modified membrane if any cleaning with water and removal unserviceable materials, debris and rubbish to a distance out side MoD land complete all as specified and directed. |
| 9 | Demolition of cement concrete in ground floors and pavings not exc 15 cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance out side MoD land complete all as specified and as directed. |
| 10 | M&L for Precast cement concrete 1:3:6 type C1 (20mm graded aggregate) solid block masonry exc. 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed. |
| 11 | M&L for Plain cement concrete 1:4:8 type D-2 by using 40 mm graded crushed stone aggregate as in foundation, filling and mass concrete, in flooring path, sub foundation etc, complete all as specified and as directed . |
| 12 | M&L RCC M-25 design mix (using 20mm graded aggregates) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc. basement slabs, under-reamed piles and mass concrete complete all as specified and as directed . |
| 13 | M&L RCC M-25 design mix (using 20mm graded aggregates) as in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and as directed . |
| 14 | M&L RCC M-25 design mix (using 20mm graded aggregates) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as directed. |
| 15 | M&L RCC M-25 design mix (using 20 mm graded granite stone aggregate) for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 16 | M&L RCC M-25 design mix (using 20mm graded aggregates) as in chajjas complete all as specified and directed. |
| 17 | M&L for flat fair finished formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed. |
| 18 | M&L for flat fair finished formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed. |
| 19 | M&l for flat fair finished formwork to sides and soffits of floor or roof beams, beam haunchings, columns, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.complete all as specified and directed. |
| 20 | M&L for flat fair finished formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. |
| 21 | M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed. |
| 22 | M&L for formwork to fair finished surfaces of concrete, square or rectangular, sides of pillars, posts, struts, piers, columns and stanchions complete all as specified. |
| 23 | M&L for TMT (Fe 500D) bars 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns hooking ends cutting bending and binding with mild steel wire (annealed) not less than 0.90mm dia or securing with clips, complete all as specified and as directed. |
| 24 | All as per item No. 23 specified here-in-above, but of 6 to 8mm dia bars |
| 25 | All as per item No. 23 specified here-in-above, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders |
| 26 | M&L for 25mm thick Plain Cement Concrete Type B0 1:2:4 (using 12.5 mm graded stone aggregate) in sub base, floors, pavings complete all as specified and directed. |
| 27 | M&L for Vitrified Ceramic tiles light shade single/double charged 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc including over 15 mm thick screed bed or bedding layer in CM 1:6 for laying in floors finishing complete all as specified and directed. |
| 28 | All as per item No.27 here in before but on vertical surfaces such as skirting over 10mm thick backing coat in CM 1:4 complete all as specified and directed. |
| 29 | M&L for glazed coloured ceramic tiles (premium quality) of size exc 0.13 sqm but not exc 0.18 sqm, as in vertical surface such as dado/skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, over & including 10mm thick backing coat in CM 1:3 complete all as specified and directed. |
| 30 | M&L for non-skid coloured ceramic tiles joint free 7 to 8mm thick (Square/Rectangular) area of each tiles exc 0.09 Sqm but n exc 0.36 Sqm in floors set and jointed in neat cement slurry and pointed in coloured cement to match including over 15 mm thick screed bed or bedding layer in CM (1:6) for laying in floors finishing complete all as specified and directed. |
| 31 | Taking down existing cement plaster on brick or stone walls, RCC surfaces, ceilings etc., including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed. |
| 32 | M&L for rendering 15mm thick in CM 1:6 on stone masonry surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 33 | M&L for rendering 15mm thick in CM 1:4 on stone masonry surfaces or concrete surface finished even and smooth using water proofing compound without using extra cement complete all as specified and directed. |
| 34 | M&L for rendering 10mm thick on fair faces concrete surfaces in CM 1:4 and finished even and smooth without using extra cement in ceilings/facia/rcc chajja etc complete all as specified and directed. |
| 35 | M&L for raking out joints/ pointing to squared rubble masonry, jodhpur type regular course built in CM 1:3 complete all as specified and directed. |
| 36 | M&L for keyed pointing to square rubble masonry Jodhpur type regular course in CM 1:3 complete all as specified and directed. |
| 37 | Taking down Chowkats or frames not exceeding 1.5 Sq. M each (Without taking off shutters from the frames) complete all as specified and directed. |
| 38 | Taking down Chowkats or frames exceeding 1.5 Sq. M each and n exceeding 4.0 Sqm each (Without taking off shutters from the frames) complete all as specified and directed. |
| 39 | M&L for PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in coping/ benching, bed blocks, for hold fast etc., including necessary form work, complete all as specified and as directed. |
| 40 | S&F powder coated Anodised aluminium frame (minimum thickness of powder coating 50 micron) for doors, windows, ventilators with aluminium section weighing 0.55Kg/m with one or more rebates or for sliding windows (2 track / 3 track), ventilators with louvers having suitable mechanism for tilting, U shaped fillets etc complete all as specified and directed. |
| 41 | S&F powder coated anodised aluminium doors/window/ ventilator shutters prepared for sliding or hanging or fixed type etc with aluminium sections weighing minimum 0.55kg/m incl necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, screws and also including handles, tower bolts, locks and hinges etc complete all as specified and directed by Engr-in-charge. |
| 42 | S&F pre powder coated aluminium decogrill all as per sample fixed to aluminium framework of windows & ventilators complete all as specified and directed. |
| 43 | S&F 5.5mm thick tinted/frosted glass, good quality exc 0.50 sqm each pane complete and fixed to aluminium framework including rubber beading complete all as specified and directed. |
| 44 | S&F 12mm thick toughened glass as in doors, partition automatic doors and similar work including cutting to shape, including all necessary decorative fittings and hydraulic machine mounted in floor complete all as specified and directed. |
| 45 | M&L for 30mm thick guniting in patches on to the required area on RCC columns, beams, stairs, lintels, retaining walls, sunshades, roofing slab etc of all sizes and shapes at any heights from existing ground floor and at any locations with cement and mortar 1:2 (1 cement : 2 sand) under 2 o 2.8 kg/cm2 pressure after removing the damaged loose spalt concrete as specified here in before and applying one coat of rust converter/KP-100 equivalent grade over reinforcement wherever necessary providing and tying in position 25mm x25mmx12 gauge dia wire MS welded mesh or smaller size over treated surface ready to receive grouts, curing for 10 days etc loose spalt concrete portions by chipping, removal of dust over treated surface and applying 5mm to 10mm thick plastering in CM 1:4 to match existing sufaces and finished even and smooth including curing for 10 days etc and removing the debris outside the MoD land in low lying areas and levelling complete all as specified and directed. |
| 46 | M&L for carrying out water proofing treatment over roof in the following stages - (i) M&L for 15mm thick in screed bed in cement mortar (1:3), mixed with integral water proofing compound all as per manufacturer's instructions over concrete surfaces finished even and smooth without using extra cement. (ii) Material and labour for UV stable single component fibre reinforced elastomeric liquid applied waterproofing membrane having solid content of 55% formulated wih PU hybrid polymers and reinforcing acrylic fibres and having sun reflectivity Index (SRI) of 106. The application of the material should be done in three coat (6 hr gap after each coat) on the substrate, applying first self priming coat at ratio of damp proof ultra and water 3:1 then 2 undiluted coat of damp proof ultra obtaining coverage @1 ltr/10 sqft in two coats (10-12 hrs gap between each coat. The vital physical and chemical parameters shall be as under. Min elongationat break of 350%, crack bridging ability of 2.5 mm @650 microns thickness, resists positive hydrostatic pressure of up to 10 bars. The material shall be appliied with brush or roller, complete in all respect as per the direction of Engr-in charge/consultant. Also, proper surface preparation along with covingat corners is must, complete all as specified and as directed.Note : - (i) The work shall be executed by the authorized applicator of the manufacturer only. (ii) The authorized applicator of manufacturer shall be approved by GE. (iii)The color of final finish shall be decided by the GE(iv)WPC shell be measured separately and paid for under respective item of schedule). |
| 47 | Taking up or down 15/25mm bore GI steel/CPVC water tubing and connections, including cleaning for refixing or removal to store. |
| 48 | Taking up or down 25mm bore GI steel/CPVC water tubing and connections, including cleaning for refixing or removal to store. |
| 49 | S&F CPVC pipes SDR 11 having outer dia 20 mm with plain CPVC SDR 11 fittings such as bends, elbows, unions and end pieces to receive the fittings, concealed in walls/ceiling or lay in floors, complete and fixed with solvent complete all as specified and as directed. |
| 50 | All as per item No.49 here in before but 25mm outer dia pipes. |
| 51 | Cutting chases, for water tubing or concealed, etc, and making good to facings where required and plastering in cement mortar (1:3) cutting not exceeding 10cm girth in brick walls complete all as specified and directed by Engr-in-charge. |
| 52 | S&F in repairs 15 mm bore long body bib cock with wall flange and aerator, brass chromium plated with fancy type and screwed down to 15 mm bore GI tubing or for brass ferrule including taking down old bib cock complete all as specified and directed. |
| 53 | S&F in repairs 15mm bore angle stop valve with wall flange, brass chromium plated, long shank and cup, screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 54 | S&F stop valves cast copper alloy (ISI marked) screwed down high pressure with crutch or butterfly handle both ends screwed for iron pipe or for union & fixed for 20/25mm dia bore complete all as specified and directed. |
| 55 | S&F 6mm thick bevelled edges high quality looking mirror of selected quality glass of any size fancy type & fixed to wall with chromium plated brass screws and cup washers etc complete all as specified and directed. |
| 56 | M&L for 75mm outlet dia PVC(SWR) floor trap with CP mild steel grating (with or without hole) including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) using 20mm graded stone aggregate complete all as specified and directed |
| 57 | M&L for 110mm outlet dia PVC(SWR) floor trap with CP mild steel grating (with or without hole) including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) using 20mm graded stone aggregate complete all as specified and directed |
| 58 | S&F tubular towel rail brass chromium plated fancy type 20mm dia and 60 cm long fixed between flanges complete all as specified and directed. |
| 59 | S&F in repairs decorative type curtain rod stainless steel finish of pipe 22 to 25 mm dia with best quality knob metal with double fitting type including stainless steel brackets (trade pattern) fixed to walls complete with two nos decorative stainless steel knobs (fincals round type with mirror optic finish) at each end , sample as approved by GE, complete all as specified and as directed |
| 60 | S&F in repair Vitreous china wash basin white circular size including brackets including 15mm bore swan neck pillar taps cast copper alloy chromium plated fancy type, with capstan heads, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shank and fly nuts, screwed for iron pipe fixed with CP waste coupling 32mm and waste pipe complete all as specified and directed. |
| 61 | S&F in repairs single piece EWC with slim soft close seat cover complete set constellation dual flush WB constellation 5 ped constellation, EWC, cistern & lid CON dual flush, seat cover constellation, cistern fitting (water saver dual flush) etc complete all as specified and directed. |
| 62 | S&F Liquid soap container of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 105gms) complete all as specified and directed. |
| 63 | S&F vitreous china, toilet paper holder, box type complete all as specified and directed. |
| 64 | Dismantling of Cast iron/AC/PVC soil, waste & vent pipe jointed in cement mortar of size 110/100mm bore, including all fittings complete all as specified & directed. |
| 65 | All as per item No. 64 here-in-above, but 75mm bore. |
| 66 | Supply & laying 75 mm bore UPVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches of suitable size complete all as specified and as directed . |
| 67 | All as per item No. 66 here-in-above, but 110mm bore. |
| 68 | S&F for 75mm bore UPVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and as directed. |
| 69 | All as per item No. 68 here-in-above, but 110mm bore. |
| 70 | S&F 75 mm bore UPVC(SWR) bends any radius with access door, complete all as specified and directed. |
| 71 | S&F 110 mm bore (SWR) UPVC bends any radius with access door, complete all as specified and directed. |
| 72 | S&F 110 mm bore UPVC (SWR) vent cowl complete all as specified and directed. |
| 73 | S&F 32 mm bore Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified and directed. |
| 74 | S&F PVC connections 15mm dia, 600mm long, with PTMT nuts & washers at both ends complete all as specified and directed. |
| 75 | S&F in repairs CP Hand Shower (Health Faucet) with 8mm dia, 1.2 Mtr long flexible tube & wall hook with N.R.V (Back flow preventer), 15 mm dia complete all as specified and directed. |
| 76 | S&F in repairs chromium plated mild steel grating 100mm dia complete all as specified and directed. |
| 77 | S&F mild steel chromium plated peg set of five fixing with wall complete all as specified and directed. |
| 78 | S&F Soap dish, vitreous china white, approximate size 160x 160x90mm complete all as specified and directed. |
| 79 | S&F for anodised aluminium snap grid frame work of 605 X 605 mm panel size of pre powder coated pre fabricated GI section including hangers for false ceiling along the Walls suspended with and including dismantling of existing false ceiling complete all as specified and directed. |
| 80 | M&L for exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid complete all as specifed and directed. |
| 81 | M&L for PVC wall panelling made out of PVC hollow core sheet overall size of panel is 3 mtr in length and 0.3 mtr in width 8mm overall thick with tongue and groove style interlocking arrangement to wall including all necessary arrangement complete all as specified and as directed. |
| 82 | M&L for preparing new plastered surfaces of walls and applying two coat of Oil Bound distemper over 2mm thick wall care putty over a coat of alkali resistant primer and complete all as specified and directed. |
| 83 | M&L for complete removal of existing treatment on old surface of walls and applying two coat of Oil Bound distemper over 2mm thick wall care putty over a coat of alkali resistant primer and complete all as specified and directed. |
| 84 | M&L for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed. |
| 85 | M&L for preparation of old painted surfaces of ceilings and applying one coat of white wash complete all as specified and directed. |
| 86 | M&L for preparing newly plastered or unplastered surfaces of walls and applying two coats of cement base paint over a coat of primer, Priming the plastered and other surface with alkali resistant priming paint complete all as specified and directed. |
| 87 | M&L for preparing old painted surfaces of walls and applying two coats of cement base paint complete all as specified and directed. |
| 88 | Surface excavation n.exc. 30 cm deep and averaging 15 deep and getting out in soft or loose soil complete all as specified and directed. |
| 89 | M&L for 75 mm thick PCC 1:4:8 type D-2 (using 20 mm graded stone aggregate), as in sub base to floor, incl well compacting & laid to levels etc, complete all as specified and directed. |
| 90 | M&L for hardcore of broken stone or boulders of gauge n exc 63mm deposited, spread, levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 91 | Supply and laying machine pressed / factory made chamfered edge cement concrete rubberised interlocking paver block, 80mm thick with 6 mm thick top layers of anti abrasive material of M-35 grade with any colour, design & pattern, & size/ shape, as approved by GE as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness made by table vibratory method using PU mould, laid in required colour & pattern over and including M&L 50 mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed. |
| 92 | M & L for 75 mm thick PCC (1:3:6) type C2 using 20mm graded stone aggregate as in plinth protection finishing the surface even and smooth without using extra cement, including expansion joint every 3m and change in direction and joint filled with sealing compound Grade A complete all as specified and directed. |
| 93 | Supply and laying machine / factory made kerb stone of M-25 grade,at or near ground level, cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, complete all as specified and directed. |
| 94 | Taking down carefully aluminium / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switchs, sockets, aluminium conductor cable with and incl wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed. |
| 95 | Taking down carefully UNSV Submain wiring(with DB any type) of any size and Services cable of any size make, type and capacity and depositing at site and making good to the disturbed surfaces complete all as specified and directed. |
| 96 | M&L for modular point wiring complete with multistranded copper conductor 1.5 Sqmm PVC insulated but unsheathed single core FR-LSH cable (RYBN) 1100 volt grade, confirming IS 694 & colour code in conduit system of wiring, drawn through in and including non-metalic PVC heavy duty concealed (including Cutting Chases and make good the distrubed surfaces as per existing finishes) conduit of size 20 mm or med grade as required as site, totally concealed in walls / and surface on floors / ceiling or fixed on surface of walls / columns / beam / tie beam etc by means of saddles and clips etc incl all conduit accessories / fittings / junction boxes / inspection covers etc of heavy grade, ISI marked and sunk terminal boxes of CI or 16 SWG pressed steel housing, totally concealed in walls with 3mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws and sunk / cup washers, for mounting of switches, sockets fan regulators etc incl 1.5 Sqmm FR-LSH cable (Green) 1100 volt grade, PVC insulated but unsheathed flexible multi stranded copper conductor cables as continuous earth wire connected to earth dolly and including modular sunken galvanized terminal boxes of same make of switch/socket/regulator with sleek and curvy cover plates, for mounting of modular swithces, sockets, fan regulators complete, suitable for One light/fan/bell point controlled by one, one way switch, complete all as specified and directed.Note:- The rates of chase cutting on wall done concealed conduit & making good good the distrubed surfaces as per existing finishes and steel terminal boxes are included in the unit rates |
| 97 | All as per Sr. item No.96 here-in-above, but One socket outlet 5 pin 5 or 6 amps on the same board controlled by one no 5 Amp switch. |
| 98 | All as per Sr. item No.96 here-in-above, but One socket outlet 5 pin 5 or 6 amps on the independent board controlled by one no 5 Amp switch. |
| 99 | All as per Sr. item No.96 here-in-above, but with using 2.5 Sq mm single core multistranded copper conductor cable for 3 pin 16 Amp socket outlet on independent board complete all as specified and directed. |
| 100 | S&F modular switch 1 way 6 Amp, 1 module complete all as specified and directed. |
| 101 | S&F modular switch 1 way 16 Amp, 1 module complete all as specified and directed |
| 102 | S&F modular socket 6 Amp 2/3 pin, combined 2 module complete all as specified and directed |
| 103 | S&F modular socket 6 Amp/16 Amp, 6 pin, combined 2 module complete all as specified and directed |
| 104 | S&F Ceiling rose, two to three terminals, bakelite body, 230 volts, complete all as specified and directed. |
| 105 | Supply and fixing LED lights fitting 1x 20W, 4 ft long, T-5 batten fitting, designed linear sleek aesthetic PVC housing, PC cover ensures soft and glare free lighting wide angle of 120 degree, upto (110Lm/W) complete all as specified and as directed. |
| 106 | Supply and fixing round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamps suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 107 | S&F bldg security LED Light Luminaire of 35/45 Watts having IP 65 protection fiting made out of pressure die cast Aluminium housing, operating Voltage 140-270 Volts with in built surge protectore, toughened glass with and including GI pipe 40 mm bracket of 1.5 m in length including drilling holes, nuts & bolts 2 coats of red oxide primer on GI pipe and fixing with wall security light on building wall connecting cable, complete all as specified and as directed. |
| 108 | S&F LED Luminaire 600mm x 600mm, 35/36 Watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. |
| 109 | S&F single pole and neutral enclosure with two pin and earth plug socket complete with one single pole MCB 20 Amp 'C' curve type, 230 volts, 10 KA complete all as specified and directed. |
| 110 | S&F and testing factory made sheet metal enclosure for MCB DB TPN 4 way 415 Volt with double door, IP-43 Protection, duly fixed/concealed in wall complete and making good disturbed surfaces of wall including necessary connection lugging with copper lugs pin/ring type complete all as specified and directed. |
| 111 | S&F and testing factory made sheet metal enclosure for MCB DB SPN 12 way 240 Volt with double door, IP-43 Protection, duly fixed/concealed in wall complete and making good disturbed surfaces of wall including necessary connection lugging with copper lugs pin/ring type complete all as specified and directed. |
| 112 | S&F MCB triple pole and neutral 415 Volt any rating from 100 Amps, with rupturing capacity 10KA, 'C' curve type, with overload and short circuit protection complete all as specified and directed. |
| 113 | S&F MCB single pole and neutral 240 Volt any rating from 63 Amps, with rupturing capacity 10KA, 'C' curve type, with overload and short circuit protection complete all as specified and directed. |
| 114 | S&F MCB single pole 230 Volt any rating from 6 to 32 Amps, with rupturing capacity 10KA, 'B' curve type, with overload and short circuit protection complete all as specified and directed. |
| 115 | M&L for sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 6 Sqmm and one run of 6 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge.NOTE: Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one Iength. |
| 116 | M&L for sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 4 Sqmm and one run of 4 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge.NOTE: Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one Iength. |
| 117 | Supply, laying and testing in trenches/on wall / in duct/ through protection pipe LT UG XLPE insulated,armoured, heavy duty electric cable, aluminium coductor, 1100 V grade,cross sectional area 25 sqmm 4 core complete all as directed. Note : Earth work and brick work measured and paid separately |
| 118 | Supply, laying and testing in trenches/on wall / in duct/ through protection pipe LT UG XLPE insulated,armoured, heavy duty electric cable, aluminium coductor, 1100 V grade,cross sectional area 16 sqmm 2 core complete all as directed. Note : Earth work and brick work measured and paid separately |
| 119 | Supply and laying of sand for sand cushioning for cable protection in trenches including punning down of sand layer all as specified and directed. Note :- Punned thickness shall only be measured and paid. |
| 120 | Supply and laying unreinforced Precast concrete cable cover, class LV, type 1, flat size 300 mm x 180 mm x 40mm, complete all as specified and directed. |
| 121 | Supply and laying unreinforced Precast concrete cable cover, class LV, type 1, flat size 250 mm x 150 mm x 40mm, complete all as specified and directed. |
| 122 | Supplying and laying of GI tubing , light grade of 40mm bore with fittings as in road crossings for cable protection complete all as specified and as directed. |
| 123 | M&L in repairs Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) wih top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC 1:3:6 type C1 in chamber, precast RCC 50mm thick in cement concrete 1:2:4 type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 mm dia with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc complete all as specified and directed. Note : (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead. |
| 124 | M&L for Auguring/Drilling/Boring of holes under road, pavement, hardstanding by trenchless technology by manual/machine, including fixing of HDPE pipe of 40mm bore dia complete all as specified and directed. |
| 125 | Supplying and laying of PVC twin core weather proof flate cable stranded copper conductor of size 2.5 sqmm complete all as specified and directed. |
| 126 | Supply and laying in trenches of HDPE double wall corrugated (DWC) pipe conforming to IS-16205: 2018 having 25 dia including earthwork depth not less than 350mm complete all as directed. |
| 127 | M&L plain cement concrete type C1 1:3:6 using 20mm graded stone aggregate as in foundation and coping of pole complete all as specified and directed. |
| 128 | S&F security light junction boxes of dimension 140x140x95 with shockproof, rustproof, termite resistant, weather proof, cable entry from bottom, pole mounting arrangement along with 3 phase 4 wire aluminium bus bar with insulators and MCB SP 0.5 Amps rating with provision of MCB, cable glands, lugs incl three core copper cable with PVC conduit from junction box to existing LED fitting. complete all as specified and directed. |
| 129 | S&F of pathway light pressure die cast powder coated housing with PC diffuser decorative luminaire, efficient high output LED with IP 66 protection suitable for LED 1x15 watt with 4 way connector for electric connection, 1.0 meter height and including foundation complete all as specified and directed. |
| 130 | Supply, install, testing and commisioning CPRI approved of outdoor cubical type, LT panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 Hz, AC supply system having bus bar chamber with copper bus bars of rating 200 Amps duly insulated by insulation of RYB colour on SMC insulators with short circuit with stand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15mm thick and inner side shall be of 2.0 mm thick MS sheet totally enclosed of size not less than 800x600x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bottom base channel of MS angle section not less than 50x50x5 mm. Entire panel shall have common aluminium earth bar of size 25x5mm at the rear with two nos earth stad, solid connection from main bus bar to switch gears with required size of copper bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearance should be minimum 600mm. MS angle section 30x30x5 mm frame with front & back openable double door system lockable / openable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as specified and directed.INCOMING :-(a) MCB TPN 415 volts 10 KA 40 Amps - 01 Nos(b) RYB LED indication lamp panel mounting typr (Set of three) - 01 No(c) Panel mounted multi function energy meter of accuracy CL-1.0 rating - 01No(d) Timer ox with 3 pole contactor 10 A - 01 SetOUTGOING :-(a) MCB TPN 415 volts 10 KA 16 Amps - 02 Nos(b) Digital timer switch along with suitable power contactors(c) Single pole and neutral enclosure with a two pin and earth plug and socket with cap complete with one single pole MCB 10 Amps - 1 Nos |
| 131 | NOTE:- (i) Qty's have been clubbed from 3 Nos sanction Job's, whose details are encl as per appx.(ii) The contract sum shall be arrived at after deducting amount of schedule of \\"Credit\\" from the Total quoted amount. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail