Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Sch 'A' Part-I (Building Work)Note : This schedule is pre-priced by MES and the pre-priced rate indicated are under Col. 5. |
| 2 | Total amount of Sch 'A' Part II (Site clearance, excavation and earth work) |
| 3 | Total amount of Sch 'A' Part III (Internal Water Supply ) |
| 4 | Total amount of Sch 'A' Part IV (Internal Electrification) |
| 5 | Total amount of Sch 'A' Part V (Road, Path, Culvert & Hard Standing) |
| 6 | Total amount of Sch 'A' Part VI (Area Drainage) |
| 7 | Total amount of Sch 'A' Part VII (Sewage Disposal) |
| 8 | Total amount of Sch 'A' Part VIII (External Water Supply ) |
| 9 | Total amount of Sch 'A' Part IX (External Electrification and DG set) |
| 10 | Total amount of Sch 'A' Part X (Refrigerator & Water Cooler) |
| 11 | Total amount of Sch 'A' Part XI (Air Cooling System) |
| 12 | Total amount of Sch 'A' Part XII (Solar Heater) |
| 13 | Total amount of Sch 'A' Part XIII (Central Air Cooling) |
| 14 | Total amount of Sch 'A' Part XIV (Rain Water Harvesting) |
| 15 | Total amount of Sch 'A' Part XV (Bore Well) |
| 16 | Sch 'A' Part - XVI (Miscellaneous Items for B/R & E/M Works)Note - This Schedule is not pre-priced by MES and the pre - priced rate indicated as \\"Rs 0.00 under col.5 siginifies this fact only. |
| 17 | INTERNAL ELECTRIFICATIONM&L for Point wiring complete for One light/Fan/Exhaust Fan/Bell point controlled by one switch with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, suitable for modular switch with modular metal flush box with inner and outer cover plate & frame etc of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed.Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.One circuit controlled by max 8 points only. |
| 18 | M&L for Point wiring complete for One light point controlled by two way switch with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, suitable for modular switch with modular metal flush box with inner and outer cover plate & frame etc of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed.Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost. One circuit controlled by max 8 points only. |
| 19 | M&L for Point wiring complete for power point controlled by one 3 pin switch socket outlet 5 Amp on the independent board with PVC insualted and unsheathed FRLSH cable 2.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, suitable for modular switch with modular metal flush box with inner and outer cover plate & frame etc of requied colour complete, including 2.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed.Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.One circuit controlled by max one points only. |
| 20 | M&L for power point wiring complete for one 15 Amps switch socket outlet point on independents board with PVC insulated and unsheathed, FRLSH cable 2.5 sqmm (nominal area), ISI marked, stranded copper conductor single core including ISI marked 20mm dia medium grade PVC conduit concealed in wall and PVC conduit in roof/floor slab, suitable for modular switch with modular metal flush box with inner and outer cover plate & frame etc of required colour complete, including 2.5 Sqmm, FRLS cable PVC insulated unsheathed multi stranded copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories and all as specified.Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.One circuit controlled by max 4 points only. |
| 21 | Supply and fixing switch piano flush type 5 Amp single pole two way with ISI marked complete all as specified and dierected. |
| 22 | Supply and fixing Exhaust Fan made of sturdy high quality engi-neering plastic, copper winding of 450 mm sweep 35 watt, 1200 RPM with approved colour and with louver shutter complete in-cluding providing/cutting the round hole of required size in wall, grouting of nuts, bolts, fix-ing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side (outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to exhaust fan motor and writing MES No. in black synthetic enamel paint/engraving tools etc complete all as specified and directed. |
| 23 | S&F MCCB VTPN DB 4 Way sheet metal enclosure 415 Volts AC, with 200 amp fully insulated strandard copper bus bar for wach phase & surrounded with neutral bars & two common neutral bars, two earth bar including cable ties for cable management suitable for housing MCCB/TPN 415 Volts as incomer IP-54 protection with metal door all enclosed on strandard steel sheet flush mounted type double door factory fabricated complete without MCB & MCCB but with enclosure blank plate complete all as specified and directed. Note:- Independent GI pipe including connected items of suitable size will be laid in connected in wall for each floor for XLPE cable 16/25 sqmm 4 core cable connection. |
| 24 | S&F MCCB VTPN DB 6 Way sheet metal enclosure 415 Volts AC, with 200 amp fully insulated strandard copper bus bar for wach phase & surrounded with neutral bars & two common neutral bars, two earth bar including cable ties for cable management suitable for housing MCCB/TPN 415 Volts as incomer IP-54 protection with metal door all enclosed on strandard steel sheet flush mounted type double door factory fabricated complete without MCB & MCCB but with enclosure blank plate complete all as specified and directed. Note:- Independent GI pipe including connected items of suitable size will be laid in connected in wall for each floor for XLPE cable 16/25 sqmm 4 core cable connection. |
| 25 | S&F dish TV cable cord of size 1.5 sqmm solid copper conductor triple insulated steel wire mesh inner sheathing earth continuity conductor & over all PVC sheathed circular complete all as specified and directed. |
| 26 | SEWAGE DISPOSALProviding, supplying and laying of DWC pipe, Class-SN8 Structured Wall polyethelene Piping systems of 200mm internal dia (Pipe with online/offline coupler and elastomeric sealing ring) with non-smooth External Annular Corrugated and Smooth Internal Surfaces (Double Wall) for non-pressure underground Sewerage & Drainage application confirming to IS:16098-2013 including all materials, labours, T&P required for proper completion of work complete all as directed and specified. |
| 27 | M&L for RCC Septic tank for 150 user designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter complete all as specified and shown on drawings No. TD-750 Sheet 1/2 & 2/2. |
| 28 | M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M-25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.60 M dia X 6.00 M effective depth complete all as specified and shown on drawings No. TD-576 Sheet 1/2 & 2/2. |
| 29 | EXTERNAL WATER SUPPLYConstruction of fly ash brick masonry valve pit chamber of size 900 mm X 900 mm X 900 mm (internal dimensions) including necessary excavation & earth work, 100 mm thick PCC (1:4:8) type D-2 as in foundation, 230 mm thick fly ash brick work in cement mortar (1:4), 12 mm thick rendering in cement mortar (1:4) on internal surface of valve pit and mild steel sheet cover of 6 mm thick and angle iron of size (50 x 50 x 6) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key (Make - Godrej or equivalent make as approved by GE complete) including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface complete all as specified and directed. Note :- Valve pit chamber should be as per TD drawing. |
| 30 | Construction of fly ash brick masonry valve pit chamber of size 1050 mm X 1050 mm X 1050 mm (internal dimensions) including necessary excavation & earth work, 100 mm thick PCC (1:4:8) type D-2 as in foundation, 230 mm thick fly ash brick work in cement mortar (1:4), 12 mm thick rendering in cement mortar (1:4) on internal surface of valve pit and mild steel sheet cover of 6 mm thick and angle iron of size (50 x 50 x 6) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key (Make - Godrej or equivalent make as approved by GE complete) including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface complete all as specified and directed. Note :- Valve pit chamber should be as per TD drawing. |
| 31 | M&L for ductile iron pipe of size 100 mm dia socket and spigot Class-7 and laid in trenches including rubber gasket joint and other accessories as required at site etc complete as specified and directed |
| 32 | Supply, installation, testing and commissioning LT, 415 Volt, 4 wire AC 50 Hz, factory made CPRI approved, in door type Panel made out of MS sheet of size 2.0 mm thick duly with powder coated & mounted on an angle iron frame, made out of 50 x50 x6 mm angle iron frame, 90 cm height, duly fixed with and including PCC foundation etc, complete with following accessories. a) MCCB, 4 pole, 125 Amp ,415V, 35 KA -01 (Incomming)(b) MCCB 3 pole, 40 Amp 415 V 25 KA- 02 Nos (Bore well pump)(c ) MCCB 3 pole, 20 Amp 415 V 25 KA-02 Nos (Pump)(d) Star delta starter suitable for submersible pump--02 Nos(e) DOL starter suitable for monoblock pump-02 Nos(f) Digital volt meter (0-500) Volts -01 No(g) Digital Ampare mter (0-100) Amp including suitable size CT of each phase-01 No(h) Phase indicator lamps (RYB) -set of 3(j) Phase sequence controller-02 Nos(k) Single phase preventor -02 Nos |
| 33 | Supply, laying, jointing & testing 3 core PVC insulated & PVC sheathed industrial copper cable suitable for 15 HP mono block pump of size 6 sqmm etc complete as specified and directed. |
| 34 | Supply and fixing CI foot valve confirming to IS 4038, ISI marked with one end flanged ends including rubber insertion sheet nut, bolts, washer of size 100 mm with all accessories as per manufacturer norms etc complete as specified and directed. |
| 35 | Supply and fixing reflex valve (non return valve) confirming to IS 5312/ ISI marked both ends flanged of pressure rating PN 1.6 and jointing with rubber or fiber board gasket including required Nos of nuts, bolts and washer of size 100 mm bore including all other accessories as required at site etc complete as specified and directed. |
| 36 | Supply & fixing butterfly valves gun metal, lever operated high pressure, flanged both ends suitable for flanged DI pipe with all other accessories as required at site confirming to IS 13095 suitable for 50 mm dia etc. complete as specified and directed by Engr-in-charge |
| 37 | Supply & fixing butterfly valves gun metal, lever operated high pressure, flanged both ends suitable for flanged DI pipe with all other accessories as required at site confirming to IS 13095 suitable for 100 mm dia etc. complete as specified and directed by Engr-in-charge |
| 38 | Supplying install, commissioning and testing ,electric driven centrifugal split monoblock type pumping set (15 HP) , 3 phase ,415 volts 3000 RPM having discharge not less than 500-1100 LPM at 40-80 mtr head with base frame & delivery size 80mm and fixing arrangement as per manufacturers instructions with necessary nuts bolts ,washers ,reducers, etc as required complete all as specified and as directed. |
| 39 | M&L for Cast iron sluice valve of size 100 mm heavy duty both ends flanged class PN 1.0, ISI marked with high tensile brass spindle, cast iron hand operated wheel and cap top, nuts, bolts, washers including 3 mm thick rubber gasket joints etc complete all as specified and directed. |
| 40 | M&L for Cast iron sluice valve of size 80 mm heavy duty both ends flanged class PN 1.0, ISI marked with high tensile brass spindle, cast iron hand operated wheel and cap top, nuts, bolts, washers including 3 mm thick rubber gasket joints etc complete all as specified and directed. |
| 41 | EXTERNAL ELECTRIFICATION & DG SETSSupply, installation, commissioning and testing of Level-III transformer copper wound step down 200 KVA , out door type, floor mounted, 50 Cycle (50 Hz), AC with oil immersed naturally air cooled (ONAN),delta connected on HV side and star connected LV side in accordance with vector group symbol DY-N11 with natural brought out on secondary side and having tapping in step of ± 2.5 % to 5.0 % and ± 7.5 % to be changed by means of hand operated off load tap changing gear including first fill of transformer oil as per IS 335 and including all fittings/accessories as specified in SSR Part-I and IS 1180 Part-I: 2014 (Latest amendment or as per latest , the transformer should have cable box on LT side and exposed brass bushing on HT side, oil temperature gauge, dehydrating breather with first filling of dehydrating agents oil conservator tank, explosion vent, rating and terminal marking plate, oil level gauge, oil drain and filter valve, providing independent earthing terminals for neutral and body complete in all respect and other standard accessories as per manufacturer norms etc all as specified and directed.Note- (i) Transformer shall be fixed on PCC plate form of size 3.0x2.5x1.2 mtr above the ground level and 0.60 mtr below ground with PCC (1:3:6) type C-2 using 40 mm graded stone aggregate with suitable steps from ground to top of plat form incl 15mm thick plaster in cement mortar (1:4) on external surface, earth work etc complete with two coat of white wash on plat form of approved shade including 1.8 mtr height channeling fencing with angel iron/channel and suitable size gate with locking arrangement as specified and painting the one coate of primer and two coat of synthetic enameled paint (90 cm black paint over the ground and 90 cm yellow paint above the black paint & including spread 40mm stone aggregate with 20 cm thick inside the channel fencing, danger notice board about -04 Nos |
| 42 | Supply & erecting two pole structure with steel tubular swaged pole complete with cast iron base plate, final taper plug, bolts, nuts & screws as specified type 410 SP-55, 11 mtr long and bracing with angle/chanel cross arms, MS flat, nut, bolt and washer etc all as specified and shown on drawings including the followings:-(a) Excavation and earth work in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points.(b) PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in foundation including form work.(c) PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in coping including form work.(d) PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in base.(e) Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coat of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block.(f) Writing letter of figures (block Roman, Italic as Indian) with thick synthetic enamel paint of apprised shade not exc 5 cm height including numbering of pole.(g) Painting of coping with cement base paint all as directed.(h) Bracing with angle/chanel iron with nut, bolt, washer, MS flat etc as shown in drg.(j) Anti-climbing device-02 Nos as specified and directed(k) Danger notice board suitable for HT -02 NosNote:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (k) only. All other connected work shall be measured and paid separately. |
| 43 | S&F cable route indicator / markers made out of PCC block (1:3:6) type C-1 using 20 mm graded stone aggregate size (bottom 400mmx 100 mm thick )+Top-300x100mm thick+height-1200mm(60 cm burried in ground with ` DANGER/11 KV UG cable MES' embossed on route marker including excavation and earth work and painting the yellow colour above the ground and write the black colour complete all as specified and directed. |
| 44 | Supply, testing and commissioning weather and vermin proof LT feeder pillar box (Panel board) factory fabricated out door cubical/kiosk type totally enclosed made out of 3.15 mm thick sheet metal enclosure of as per 15:5039/1983 partially type tested with angle iron frame of M.S. angle 50x50x6mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes of prevent ingress of water/vermin etc inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly spray painted grey hammer tone with one coat of red oxide primer and two coats of synthetic enamel paint of grey or any other approved colour, including connecting and comparing of following :-(a) 4 Nos Copper bus bars, 3 Nos for phase (R,Y,B) of rating 400 Amp and 1 for neutral rating 400 amp mounted on heavy duty rubberised / porcelain support.(b) MCCB 300 Amp,35 KA, 4 pole 415V, 50HZ, with thermal magnetic OL&SC+ electric earth leakage -01 (Incomming) (c) MCCB 63 Amp,25 KA, 4 pole 415V, 50HZ, with thermal magnetic OL&SC - 06 Nos (DH/AC abd pump house)(d) MCCB 40 Amp 25 KA 4 pole 415 V 50 HZ-09 Nos (OTM bldg + one spare)(e) MCCB 20 Amp 25 KA 4 pole 415 V, 50 HZ- 01 Nos (Street light)(f) Ammeter (0 to 400) amp, Digital type having scroll type switch with CT’s.(g) Voltmeter (0 to 500) V, Digital type scroll type switch(h) Indicator lamp LED type (set of 3)-01 Nos(i) Digital timer time switch -01 Nos(j) Power contractor suitable capacity -01 Nos |
| 45 | S&F MS Junction box of size 300 x 200 x 150 mm grade made from 16 gauge steel sheet with 04 Nos aluminium bus bar of size 25 mm x 3 mm fixed on porcelain support with hinged cover and locking arrangement fixed to pole with ms clamp of size 25x3mm thick and tighting with nut bolt and washer and duly spray painted grey hammer tone with one coat of red oxide primer and two coats of synthetic enamel paint of grey or any other approved colour etc complete all specified and directed. |
| 46 | Supply and fixing street light luminaries suitable for LED 70-75 watts new generation energy saving and environmental long life made up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover having top opening separate driver compartment with IP -66 protection and impact resistance of IK07 suitable for 41mm dia pipe including 2 single core 1.5 sqmm PVC insulated stranded copper conductor cable from junction box to light fitting connector etc complete as specified and directed. |
| 47 | S&F stellar LED post top lantern fitting 60 watt offering combination of sturdy design , excellent illumination and aesthetics in on go IP 66 and IK10 rating ensures it stand tall amid varied environmental conditions suitable for 76 mm dia etc with all accessories including suitable size GI pipe and fixing in RCC wall/floor etc complete as specified and directed. |
| 48 | M&L for boring of holes Horizontal upto 150 mm dia under road crossing, pavement, hard standing by trenchless technology using ultra technique and necessary machine complete all as specified and directed |
| 49 | Supplying, installation, testing & commissioning of 11 KV, 630 Amps, 21kA for 1 sec extensible IP54 manual Outdoor type SF6 gas insulated 630 Amp Copper busbar RMU extensible comprising of 1 Load Break switch & 2 outgoing VCB as details below. The LBS/VCB shall be enclosed in robotically welded minimum 2.5 mm thick non magnetic, non ferrite Stainless Steel tank filled with SF6 with IP class IP67 , leak rate less than 0.1% and tested for internal arc fault of 21kA upto 01-second as per latest IEC 62271-200. The unit shall have front cable entry for ease of installation. VCB should preferably have 2000 operations via mechanically latched push buttons to meet frequent operating requirements. The unit shall include the following with all necessary standard fitting required at site:- |
| 50 | Load break switch module - 1 Nos. Manually operated 12 KV, 630A Load Break switch and Earthing Switch with making capacity “Live Cable” LED Indicators through Capacitor Voltage Dividers mounted on the bushings. Earth fault passage indicator one per LBS Mechanical ON/OFF/EARTH Indication Cable boxes suitable for 1x3Cx95-120 sq mm XLPE Cable with right angle Cable Termination Protectors, situated towards side of RMU Cable Door should be arc proof and interlocked with respective Earthing Switches. For safety of operator it should not be possible to open the cable Door unless the earth Switch is ON Vacuum circuit Breaker module - 02 No. (b) Vacuum Circuit Breaker Module 2 nos. Outgoing :(i) 630A Vacuum Circuit Breaker module for making and breaking of fault current alongwith Earth Switch of full making capacity.(ii) Short time breaking current - 21KA/ 3 sec. Making Capacity - 52.5KA(iii) Internal Arc - 21kA/1 sec(iv) Nominal operating gas pressure - 1.3(minimum) Bar abs. (v) Power frequency withstand voltage - 28KV(vi) Impulse withstand voltage - 75KV(vii) Outdoor Enclosure - IP55 (viii) Front cover mechanism - IP2X(ix) Cable covers - 3X(x) Stored Energy mechanism for Motor operation- 24VDC(xi) Cable box for front termination of the cable suitable upto 3 core 400 Sqmm, 11 KV XLPE cable(xii) Operation Counter(xiii) Self- Powered Microprocessor based Relay (3 O/C & E/F) with RS485 port and with standard settings - ADR241S |
| 51 | (xiv) Protection CT - 50-100/1A, Cl- 5P10, 2.5VA burden (not applicable for Bus Coupler VCB) (xv) Suitable site replaceable Cable bushings(xvi) Arc proof cable covers with self Interlocking mechanism between doors, earth switch, disconnector & VCB(xvii) Capacitive voltage indication fixed type system (xviii) Mechanical Indications for breaker ON, OFF, EARTH, TRIP, Spring Charged-Discharged, Vacuum Interrupter should be of same make. Cable box should be arc proof with bolted door and interlocked with respective earthing switches. Doors should be removable for the ease access to terminate cables. |
| 52 | Supply, installation, commissioning and testing of silent Diesel Engine driven, factory assembled (Engine-direct injection, water cooled,4 cylinder 4 stroke, rated at 1500 rpm confirming to ISO 3046/BS5514 with ra-diator cooling, mechanical governor/exhaust mainfold with ss exhaust flexible, fly wheel and flywheel housing, fuel and lobe oil flters,dry type air cleaner , starter motor, battery and battary charger with suitable alternator and acoustic enclosure : power coated weather proof canopy and SS exhaust bellow optimised to meet stringent MOEF/CPCB norms for sound and emission, baserail with drawout type fuel tank, drain plug,inlet and outlet connections airvent,level guage and control AMF panel with fabricated from CRCA sheet powder coated with RAL 9003 incl MCB suitable rating with short circuit protection,controller with multi feature display,load on and set running indication lamp, copper conductor cables between alternator to control panel) incl foundation as per manufacturer drawing etc complete as specified and directed and Diesel Engine Gen Set shall comprising of the following:- (i) Genset Specification (a) Gen set rating -Prime(b) Gen set out put 40 KVA(c) Gross Engine Power -15.9 kWm (d) Cooling- water cooled. (e) Nos of cylender -4/inline(f) Compression ratio-17.5(g) Rated RPM-1500(h) Over speed trip (RPM)-1650(i) Governor type/Class -Mech/G2(j) Frequency regulation-Isochronous(k) Air cleaner type/qty-Dry/01 |
| 53 | (ii) Exhaust System(a) Max allowable backup pressure -4 kPa(b) Exhaust Temp-550 degree centigrade(c) cylinder type- Critical(iii) Engine Electrical System(a) Charging alternator VDC/Amp -12V/35A(b) Starter motor rated voltage (DC)-12(c ) battery voltage (DC)/Capacity (AH)-12 V/88 AH(iv) Fuel System(a) Recommended fuel -IS 1460, HSD(b) Fuel tank Capacity -60 Ltrs(v) Alternator Specification(a) Voltage single phase 415 volts(b) Frequency -50 cycle(c ) Current three phase- 65.21 Amp(d) Type- 4P, ratating field(e) Voltage regulator -solid state and percentage- ±1%(f) Insulation class-H(VI) Cooling System(a) Max ambient capability -50 degree Centigrade(b) Coolant capacity (Eng+Rad) (L)-7.5 |
| 54 | (vii) Controller (a) Compact and micro processor based fully configurable control unit - Engine oil pressure/low oil pressure(b) Graphic display-Coolant temperature(c ) Unique integrated DG set controller-fuel level indicator %,Low battery voltage, Engine over speed(d) Incorporates both, engine and alternator parameters in a single console- Battery voltage, low fuel level, engine under speed(e) controller with inbuilt RS 485 port-DG set running hours(viii) Noise level less than or equal to 75db (A) at a distance of 1.0 mtr from the acoustic encloser as per CPCB |
| 55 | REFRIGERATOR & WATER COOLERSupply installation and testing single door refrigerator of capacity 195 liter, electric driven, single phase, 135-290 volt, AC, 50 Hz, 5 star rated with direct cooling , defrost system, tounghened glass shelves vegriable crisper and egg tray, reciprocating compressor suitable capacity & suitable for R-660a refrigerant gas and other accessories as per manufacturer norms, including plug top 5/15 Amps and necessary electric connection complete all as specified and directed. |
| 56 | Supply installation and testing double door side mounted refrigerator of capacity 310 liter, electric driven, single phase, 100-290 volt, AC, 50 Hz, 5/4 star rated with frost free design, invertor compressor for efficient cooling and other accessories as per manufacturer norms, including plug top 5/15 Amps and necessary electric connection complete all as specified and directed. |
| 57 | Supply installation and testing double door side mounted refrigerator of capacity 360 liter, electric driven, single phase, 100-290 volt, AC, 50 Hz, 5/4 star rated with frost free design, invertor compressor for efficient cooling suitable for R-134a/R-600a refrigerant , freezer capacity 89-90 ltrs and fridge capacity 270-280 ltrs , multiair flow, convertible function, deodorizer, humidity control and stabilizer free operation, smart features and other accessories as per manufacturer norms, including plug top 5/15 Amps and necessary electric connection complete all as specified and directed. |
| 58 | S&F wall mounted air cooled voltage stabilizer 1.0 KVA for autometic voltage correction single phase naturally air cooled indoor type and designed for input variation between 160 V to 260 V with out put voltage stabilized at 220 Volts ± 9% volt and high low voltage cut off with facility of including instant start & time delay relay of 3 minute capacity complete all as specified and directed. |
| 59 | S&F wall mounted air cooled voltage stabilizer 2.0 KVA for autometic voltage correction single phase naturally air cooled indoor type and designed for input variation between 160 V to 260 V with out put voltage stabilized at 220 Volts ± 9% volt and high low voltage cut off with facility of including instant start & time delay relay of 3 minute capacity complete all as specified and directed. |
| 60 | AIR COOLING SYSTEMS&F wall mounted air cooled voltage stabilizer 5 KVA for autometic voltage correction single phase naturally air cooled indoor type and designed for input variation between 160 V to 260 V with out put voltage stabilized at 220 Volts ± 9% volt and high low voltage cut off with facility of including instant start & time delay relay of 3 minute capacity complete all as specified and directed. |
| 61 | S&F power units with 25 Amp starter including 4 model plate, 25 Amp plug & socket, PVC box for mounting of power unit suitable for 25 Amp power unit and connection of electric supply and testing complete all as specified and directed. |
| 62 | M&L epoxy powder coated or polystrene insulated material sheet metal enclosure, factory made (double door), 4 way VTPN suitable for MCCB DB's, 415 Volts with 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting suitable for the following complete all as specified and directed. (a) MCCB 3 pole 63 A, 25 KA- 01 No(b) MCB SP 32 A, 10 KA C series-12 Nos |
| 63 | CHIMNEYSupply , Installation , Testing and commissioning of commercial mechanical chimney consisting of Baffle hood with filter (SS 302) of size 85 X 48 inches with suitable size SS grills including suitable size SS duct, for exhaust purpose the length of chimney should be minimum 30 feet approx and thickness of stainless steel sheet should not be less than 1.0 mm including industrial exhaust fan 900 mm sweep 3 phase 415 Volt complete fitted 02 Nos on both side in SS baffle hood . Note:- (i) All civil work which is involved in above subject works included in the works. (ii) in any items is left out which is required at site as per manufacture specification or MES specification also included in the works. (iii) Two earthing of above subject works also included in the works. |
| 64 | CENTRAL AIR COOLINGSupply and installation of Air Cooler of capacity 30000 CMH, 3.0 KW, 3 phase 415 volts, 50 Hz, 1440 RPM noise DB ≤ 79 made of engineering plastic injection moulding body, top/down discharge including dust filter, water tank should not less than 60 Ltr with water drain feature on auto/manual mode and installation of all connected items i.e double delectation grills of suitable size and Nos, including GI ducting (22 Gauge) with canvas/thermal insulation alongwith three phase electrical connection, mounting arrangement of Air Cooler on MS structure as specified/marked in plan of buildings complete all specified and directed. |
| 65 | Supply and installation of Air Cooler of capacity 22000 CMH, 1.50 KW, 3 phase 415 volts, 50 Hz, 1440 RPM noise DB ≤ 79 made of engineering plastic injection moulding body, top/down discharge including dust filter, water tank should not less than 35 Ltr with water drain feature on auto/manual mode and installation of all connected items i.e double delectation grills of suitable size and Nos, including GI ducting (22 Gauge) with canvas/thermal insulation alongwith three phase electrical connection, mounting arrangement of Air Cooler on MS structure as specified/marked in plan of buildings complete all specified and directed. |
| 66 | Supply and installation of Air Cooler of capacity 18000 CMH, 1.50 KW, 3 phase 415 volts, 50 Hz, 1440 RPM noise DB ≤ 79 made of engineering plastic injection moulding body, top/down discharge including dust filter, water tank should not less than 35 Ltr with water drain feature on auto/manual mode and installation of all connected items i.e double delectation grills of suitable size and Nos, including GI ducting (22 Gauge) with canvas/thermal insulation alongwith three phase electrical connection, mounting arrangement of Air Cooler on MS structure as specified/marked in plan of buildings complete all specified and directed. |
| 67 | Supply and installation of belt driven silent Exhaust fan of capacity 10000 CMH, 1440 RPM, 3 phase 415 volts, 50 Hz, power consumption 0.37 KW with auto shutter feature and size not more than 650mmx650mmx 460mm including three phase electrical connection with necessary opening in the wall for fixing the same complete all specified and directed. |
| 68 | Supply and installation PVC grill size not less than 8x16 inch to allow the airflow in side the building and ensuring comfort in interior space complete all specified and directed. |
| 69 | Supply and fixing mild steel structural work as per site requirement for mounting the PVC water tank (Make up tank) as per air cooler requirement complete all as specified and directed. |
| 70 | RAIN WATRER HARVESTING: M&L for Plain PVC pipe, 152 mm dia bore as per IS 12818-2021 for boree and tube well including lowering & jointing complete all as specified and directed. |
| 71 | M&L Screened PVC Pipe 152 mm dia bore as per IS 12818-2021 for boree and tube well including lowering & jointing complete all as specified and directed. |
| 72 | M&L for Trial bore of 200 mm dia upto 90 mtr depth below GL in any kind of Soil strata including hard stone/boulder including electric logging MS Cap., MS flat iron clamps, reducing socket etc complete all as specified and directed. |
| 73 | M&L for Reaming of bore upto 300 mm (only for recharge well) pilot bore in any kind of soil/strata including hard stone/boulder by means of direct rotary method upto and including 60 RM depth each below ground level complete all as specified and directed. |
| 74 | M&L for Pea Gravel packing for trial bores of size to be designated by the contractor natural shape brought direct from river bed and packing around the casing pipe to entire depth upto ground level complete as directed. |
| 75 | M&L for Development of bore wells by means of high velocity jetting together with air compressor having capacity not less than 100 PSI for pumping out mud/dirty water complete all as specified and directed. |
| 76 | M&L for PVC end cap for 152 mm bore pipe. complete all as specified and directed. |
| 77 | Supply and laying Plain PVC bend 87.5 degree for 152 mm bore pipe with nylon wiremesh for to covering one end complete all as specified and directed. |
| 78 | BORE WELLM&L for drilling verical bore 200 mm dia from 0 to 60 m deep below ground level at site thorugh any kinds of soil including hard/stone/boulder by means of direct rotary method and all works peertaining to pilot boring complete all as specified and directed |
| 79 | M&L for drilling verical bore 200 mm dia exceeding 60 mtr but not exceeding 200 mtr deep below ground level at site thorugh any kinds of soil including hard/stone/boulder by means of direct rotary method and all works peertaining to pilot boring complet all as specified and directed |
| 80 | M&L for drilling verical bore 200 mm dia exceeding 200 mtr but not exceeding 300 mtr deep below ground level at site thorugh any kinds of soil including hard/stone/boulder by means of direct rotary method and all works peertaining to pilot boring complet all as specified and directed |
| 81 | M&L for drilling verical bore 200 mm dia exceeding 300 mtr but not exceeding 490 mtr deep below ground level at site thorugh any kinds of soil including hard/stone/boulder by means of direct rotary method and all works peertaining to pilot boring complet all as specified and directed |
| 82 | Reaming (expanding) vertical bore of pilot bore of 200mm dia to 675mm from 0-60 m deep below ground level of reaming 675 mm size including all works pertain to boring complete all as specified and directed . |
| 83 | Reaming (expanding) vertical bore of pilot bore of 200mm dia to 525mm exceeding 60 m but not exeeding 200 m deep below ground level of reaming 525 mm size including all works pertain to boring complete all as specified and directed . |
| 84 | Reaming (expanding) vertical bore of pilot bore of 200mm dia to 525mm exceeding 200 m but not exeeding 300 m deep below ground level of reaming 525 mm size including all works pertain to boring complete all as specified and directed . |
| 85 | Reaming (expanding) vertical bore of pilot bore of 200mm dia to 525mm exceeding 300 m but not exeeding 490 m deep below ground level of reaming 525 mm size including all works pertain to boring complete all as specified and directed . |
| 86 | M&L for mild steel sheet casing plain ERW casing pipe 300 mm bore, 8mm thickness conforming to IS 4270 -2001, ISI marked, lowering and fixing in position upto required depth in all strata cut into different length including cutting, welding pipe jointed and welded coupler rings through out circumference of the pipe and coupler rings both side as in bore wells complete all as specified and directed.Note-(i) Length of each pipe shall not be less than 2.4 m except where pipe length required in less than 2.4 m.(ii) Welding shall be done through out the circumference of the pipe and coupler rings both side. |
| 87 | M&L for mild steel sheet casing plain ERW casing pipe 200 mm bore, 8mm thickness conforming to IS 4270 -2001, ISI marked, lowering and fixing in position upto required depth in all strata cut into different length including cutting, welding pipe jointed and welded coupler rings through out circumference of the pipe and coupler rings both side as in bore wells complete all as specified and directed.Note:-(i) Length of each pipe shall not be less than 2.4 m except where pipe length required in less than 2.4 m.(ii) Reducing socket shall be measured and paid seperatly.: |
| 88 | M&L V-strainer (Johnson screen pipe) of size 200mm bore of thicness 8mm and maximum length of stainer 3 mtr long low carbon galvanised steel (stainless steel) , plain welded ends in built welding slots of size 0.75 mm wide uniformaly distributed on surfaces and fixed on position cut into diffrenet length including cutting, welding pipe, jointed and welded coupler rings through out the circumference of pipe complete all as specified and directed. |
| 89 | M&L for mild steel reducing socket of size 350 mm x 200 mm incuding welding MS strip of size 40x6mm (02 Nos) on each joint extended 100 mm on each side complete all as specified and directed.Note:-The wall thickness of the socket side shall not be less than 7.04mm |
| 90 | M&L for well cap of 350mm dia and 8mm thick size on top of the pipes with locking arrangement complete all as specified and directed. |
| 91 | M&L for mild steel bail plug 200mm size, 10mm thick of 1 mtr long with ms rod 25mm dia size welded to it a bottom bail hook complete as specified and directed |
| 92 | M&L for pea gravel of size 3mm to 6mm size of approved quality as order to peak around the casing /slotted pipe in bore well to entire depth upto to ground level complete all as specified and directed |
| 93 | M&L for MS flat iron (two Nos) 150mm x16mm thick size clamp for holding with 350mm bore housing pipe including casting pcc block of size 1200mm x1000mmx1000mm in pcc (1:2:4) type B-1 using 20mm graded stone aggregate including 150mm bore MS pipe two Nos each 1.5 mtr long with cap plug and cap top for feeding pea gravel for each bore well complete as specified and directed |
| 94 | M&L for mild steel black column pipe 3 mtr long heavy duty 100 mm bore wall thickness 4.85 mm both end flanged with heavy duty MS flanged not less than 16mm thick screwed and welded inside and outside. The flange end making surface shall be made smooth including welding of 4 strip of 5.0 mm thick 25mm wide and 50mm long covering pipe and both end flanged having 08 Nos predrilled hole not less than 16mm including rubbber gasket nut bolts and washer. Pipe shall be duly painted with anti-corrosive paint complete all as specified and directed |
| 95 | M&L for strat sample box with glass cover 3mm thick having internal dimension 1000mmx600mmx100mm made out of 20mm thick wrought Ist class hard wood shisham with hinges, hasp and staple including polishing complete with samples at various strata met in boring including strata chart made in cloth/approved material in duplicate complete all as specified and directed. Please Enable Macros to View BoQ information |
| 96 | M&L for strat sample box with glass cover 3mm thick having internal dimension 1000mmx600mmx100mm made out of 20mm thick wrought Ist class hard wood shisham with hinges, hasp and staple including polishing complete with samples at various strata met in boring including strata chart made in cloth/approved material in duplicate complete all as specified and directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
| 9 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy