| 1 | Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above itmes should be made as per conditions seperately0 and making good disturbed surfaces of walls, floors etc |
| 2 | Supply & fix preparing new or previously untreatedsteel surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide or zinc chrome primer on steel surfaces complete all as specified and directed by Engineer-in-Charge. |
| 3 | Pulling out sub main wiring only any size of aluminium conductor cable PVC insulated with or without condiut complete all as specified and directed by Engineer-in-Charge. |
| 4 | Material & labour for point wiring complete with 1.5 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade ISI marked drawn through and including PVC CASING & CAPPING INCLUDING accessories etc including fixed to wall/ceiling including provision of 1.5 sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed as earth wire continuity with PVC surface box complete all as specified and directed by Engineer-in-Charge for :- |
| 5 | One 3 pin 5 Amps/ 6 Amps socket out let on independent board |
| 6 | All as per item No 4 here -in-before but with 2.5 sqm copper conductor cable for oe 3/5 pin, 6/16 Amps socket out let on indpendent board |
| 7 | Material & labour for sub main wiring with two runs of PVC insulated and unsheathed FRLSH cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 2.5 Sqmm single core, copper conductor drawn through and including PVC casing caping ISI marked with accessories and 2.5 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed by Engr-in-Charge.(Note: Two runs of conductor with one run of earth wire and PVC casing capping will be measured & paid as one unit) |
| 8 | All as item No 5 but with4 sqmm copper conductor through PVC conduit/PVC |
| 9 | S&F in replacement modular switch, 5 Amps/ 6 Amp flush type 1 module all as directed/ specified |
| 10 | S&F in replacement modular socket 5 Amps/ 6 Amp flush type 2 module all as directed/ specified |
| 11 | S&F in replacement modular switch, 16 Amp flush type 1 module all as directed/ specified |
| 12 | S&F in replacement socket 6A/16A - 2/3 pin combined 2 module all as directed/ specified |
| 13 | S&F in replacement modular white cover plate with frame of module 3 flush ISI marked all as directed/ specified |
| 14 | S&F in replacement modular plastic surface box of module 3 flush ISI marked all as directed/ specified |
| 15 | Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in hard/dense soil complete all as specified and directed by Engineer-in-Charge. |
| 16 | Supply & install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR complete all as specified and directed by Engineer-in-Charge. |
| 17 | Supply & fix voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stablized at 230 V with low and high cutoff facility including under and over current protection with accurancy of + 2.5% and of capacity 4.0 KVA complete all as specified and directed by Engr-in-Charge. |
| 18 | Supply & fix PVC clad enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps complete all as specified and as directed by Engineer-in-Charge. |
| 19 | Material & labour for precast cement concrete block masonry type 1:3:6 using 20mm graded stone aggregate with solid blocks, exc 10cm in width and setting in CM 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 20 | Supply & fix TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia complete all as specified and directed by Engineer-in-Charge. |
| 21 | Material & labour for precast reinforced cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, shelves and similar articles with plain faces, set in CM 1:4, including necessary form work moulds etc complete all as specified and directed by Engineer-in-Charge. (Reinforcement shall be measured and paid for separately). |
| 22 | S&F Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing handle 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified |
| 23 | Material & labour rendering 10mm thick in CM 1: 6 on fair faces of conc, brick work surface incl finishing the surface even and smooth without using extra cement all as specified |
| 24 | Material & labour for preparing new plastered surfaces of walls and applying two Coats of acrylic washable distemper over a coat of chalk whitening complete all as specified and directed by Engineer-in-Charge. |
| 25 | Supply & fix anodised aluminium frame for doors, windows, ventilators and fixed partitions with one or more rebates including joining cleat for fixing etc complete all as specified and directed by Engineer-in-Charge |
| 26 | Supply & Fix for 4.00 mm thick sheet glass ordinary quality and glazing with oil putty in square exc 0.50 Sqm in each pane complete all as specified and directed by Engineer-in-charge. |
| 27 | Supply & Fix for prelaminated particle board 9mm thick interior grade prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to timber frame work fixed for cuboards/shelfs etc complete all as specified and directed by Engineer-in-charge. |
| 28 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/ loose soil complete all as specified and as directed by Engineer-in-Charge. |
| 29 | Material & labour for PCC 1:2:4, B2 ( using 40mm graded stone aggregate) in foundations filling and mass concrete complete all as specified and directed by Engineer-in-Charge. |
| 30 | Supply & fix mild steel pipe (tubular) fixed as vertical post including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S. 1161-1979 grade St.-240 as in posts complete all as specified and as directed by Engineer-in-Charge. |
| 31 | Supply & fix steel work as rafters and web in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S. 1161-1979 grade St.-240 complete all as specified and directed by Engineer-in-Charge. |
| 32 | Supply & fix mild steel plates, plain or chequered, in Fe 410-W (Gde-E- 250) quality-A complete all as specified and directed by Engineer-in-Charge. |
| 33 | Supply & fix mild steel screw bolts 16 to 20 mm dia of neck (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm long and n exc 10 cm long complete all as specified and directed by Engineer-in-Charge. |
| 34 | Supply & fix pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550MPA as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge. |
| 35 | Supply & fix pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550MPA as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge. |
| 36 | Material & labour for plain Cement concrete, type D2, (1:4:8), (using 40mm graded stone aggregate) in foundation and filling mass concrete complete all as specified and as directed by Engineer-in-Charge. |
| 37 | Material & labour for 50 mm thick cement concrete type B-1,1:2:4 mix (using 20 mm graded stone aggregates) as in copings including necessary use and waste of form work complete all as specified and directed by Engineer-in-Charge. |
| 38 | Material & labour for cement concrete (1:3:6) type C-2 (using 40 mm graded aggregate) as in bed to drain pipe and packing under and haunching against the sides of pipes after they are laid and tested complete pipe size of 200mm bore complete all as specified and as directed by Engineer-in-Charge. |
| 39 | Material & labour for rendering 10mm thick in CM 1:6 followed by 5mm thick in CM 1:4 on brick work/concrete surface of walls finished even and smooth without using extra cement with WPC @ 3% by weight of cement |
| 40 | Supply only water proofing compound confirming to IS |
| 41 | Material & Labour for preparation of new plastered surface of walls and applying two coats of exterior emulsion paint camoflage pattern paint over a coat of wall primer |
| 42 | Material & labour for salt glazed stone ware drain pipe grade A ISI marked laid to slope in trenches, jointed in CM (1:2) and tested complete of size 200mm dia complete all as specified and directed by Engineer-in-Charge |
| 43 | Removing excavated material soil exc 250m but n exc 500m and depositing where directed at level n.exc 1.5m above starting point complete all as specified and directed by Engineer-in-Charge |
| 44 | Returing & filling in slil in trenches including spreading, levelling and waterin in layers n. exc 25 cm as directed by Engineer-in-charge |
| 45 | Material & labour for one light point/ fan point controlled by one , one way flame proof switch surface wiring complete with 1.5 sqmm single core multi stranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade drawn through ERW steel conduit heavy duty ISI marked of size 20 mm including dia accessories like tees, bends elbows, reducers bell mouth tube ends and fixing accessories such as couples, rock nuts saddles, pipe hooks etc complete all as specified and directed by Engineer-in-Charge. |
| 46 | All as per item No 43 but with 2.5 sqmm all as specified and directed by Engr-in-Charge |
| 47 | Supply & fixing flame proof/weather proof 4 feet LED light fitting 2x18 Watt CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size etc complete all as specified and directed by Engineer-in-Charge. |
| 48 | Supply & fix flame proof/weather proof exhaust fan, 12\\" (300mm), single phase,with and including louvers complete CMRI certified recommended for gas group of IIA & IIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing complete all as specified and directed by Engineer-in-Charge.Note:-The rate quoated shall be in including making holes of suitable for exhaust fan of size 300 mm dia in PCC block masonry wall, making good the side of hole with CM (1:4) on wall with two coat of paint match with existing wall and distributed surface with 4 nos of stainless steel fastner of suitable size to fit the exhaust fan no extra payment will be allowed to contractor on this regard |
| 49 | Supply and fix Flame proof/ weather proof on/off switch with termination box in LM6, 16A 2 pole 250V |
| 50 | Supply & Fix Flame proof/ weather proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth. |
| 51 | Material & labour for sub main wiring with two runs of PVC insulated and unsheathed FRLSH cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 4 Sqmm single core, copper conductor drawn through and including conduit medium grade/new casing capping ISI marked with accessories and 4 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed by Engr-in-Charge. (Note: Three runs of conductor for phase with one run of neutral and one run for earth wire and PVC conduit/casing capping will be measured & paid as one unit) |
| 52 | Supply and fixing single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amp complete |
| 53 | Supply & fixing LED flood light 210 watt 230V AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp. |
| 54 | Supply and fixing XLPE insulated, armoured heave duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq mm two core. |
| 55 | Excavating in trenches, n exc 1.5m wide and exc 1.5m in depth, for foundation etc or for shafts, wells cesspits, manholes, pier holes etc. n 10 sq m on plan n exc 1.5 m in depth and getting out in soft/ loose soil |
| 56 | Removing excavated soil to a distance n.exc. 50 mtr and depositing where directed at a level n.exc. 1.5m above the starting points complete all as specified and directed by Engineer-in-Charge. |
| 57 | Material & labour for sand filling under floors or in foundations including watering and consolidation all as specified and directed by Engr-in-ChargeNote: Punned thickness shall be measured for payment. |
| 58 | Supply and laying un-reinforced precast concrete cable cover, class LV type I flat with peak size 300mm x 180mm x 40mm laid transverse to cable |
| 59 | Supply and fixing galvanised Medium class pipe including fittings of dia 80mm (3\\") dia complete |
| 60 | Material & labour for cutting the existing GI/DI pipe of size 80 mm dia and taking 80 mm dia branch connection including necessary fittings etc complete all as specified and directed by Engineer-in-Charge. |
| 61 | Supply & fix in replacement double door sheet metal enclosures factory made DBs protection class IP-43, suitable for fixing of MCBs, Isolators etc, confirming to IS 13032 triple pole and neutral 4 ways with 200 Amp rated bus bar 415 volts powder coated complete all as specified and directed by Engineer-in-charge |
| 62 | Supply & Fix isolator /MCBs of the under mentioned type and rating and fixing in DBs |
| 63 | SPN 240 Volts 40 Amps capacity C Series |
| 64 | SP 240 Volts 6-32 Ampx Capacity C Series |
| 65 | M & L for cement concrete in foundation filling and mass concreting type C-2 1:3:6 (40mm graded aggregate) complete all as directed by Engr-in-charge |
| 66 | Supply & fix rolled steel pipe or other steel section for post framing for cladding, fixed with angle cleats, base plates necessary nuts, bolts etc as in posts complete all as directed by Engr-in-Charge |
| 67 | Supply & Fix roof trusses (framed) trussed, purling post crane gatries rall and fastenings and heavy bracket framing (beam, tee, angle channel or flat sections) including distance pieces cleats complete all as directed by Engr-in-charge |
| 68 | M&L pre-painted aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified & directed by Engr-in-charge |
| 69 | M&L preparation of new untreated surfaces of any description not described over 10cm in width or girth and applying two coats synthetic enamel paint on over one coat of red oxide on new steel surfaces complete all as specified & directed by Engr-in-charge |
| 70 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in avg soil and as directed by Engr-in-Charge |
| 71 | Demolition of cement concrete unreinforced of any description and in any position not otherwise specifically provided for complete all as specified and as directed and as directed by Engr-in-Charge |
| 72 | M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete and as directed by Engr-in-Charge |
| 73 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for fair finished surface and as directed by Engr-in-Charge |
| 74 | M&L for reinforced cement concrete 1:2:4 Type B-1 (20mm graded aggregate as in footings, foundation beams, plinth beams, bases for column etc all as specified and as directed by Engr-in-Charge |
| 75 | S&F for TMT bars 10MM dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90MM dia and as directed by Engr-in-Charge |
| 76 | All as per item No 71 abvoe , but 6 MM dia and over upto and including 10MM dia in stirrups spacers and bindersand as directed by Engr-in-Charge |
| 77 | M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions Square rectangular on plan fair finished all as specified and as directed by Engr-in-Charge |
| 78 | M&L for reinforced cement concrete 1:2:4 Type B-1 (20mm graded aggregate) in column, pillar, piers, posts and struts all as specifiedand as directed by Engr-in-Charge |
| 79 | S&F MS Plates (plain or chequered) channels Fe 410 -W (Gde- E- 250) quality-A, square cut or notched (ordinary and counter sunk) forming holes, without any attachment all as specified and as directed by Engr-in-Charge |
| 80 | S&F Mild steel rag or lewis bolts of 20 mm of dia of neck, screwed one end, with hexagonal or square nuts and ashers, the other end enlarged and jagged or lewised, exc 15cm longand n exc 30cm long all as specified and as directed by Engr-in-Charge |
| 81 | S&F mild steel work in tubular trusses/structures of square/round/ rectangular pipes, rafters, purlins including special shaped washer etc. complete using ERW or inductuin butt welded tubes confirming to IS-1161-1998 grade St-240 including notching, drilling, fitting, rivetting and or welding or connecting bolts and nuts, cleats, gusset plates etc complete all as specified and as directed. Note : Rates quoted for all items should include working upto 10m height including all necessary scaffolding , staging ,machinery etc complete all as specified and as directed |
| 82 | M&L for rendering 10mm thick in CM 1:6 followed by 5 mm thick in CM 1:4 on brick work/concrete surface of walls finished even and smooth without using extra cement all as specified and as directed by Engr-in-Charge |
| 83 | M&L for preparation of new or previously untreated concrete or PCC block masonry external surfaces and applying two coats of exterior emulsion paint (in camouflage pattern as approved by the GE) over a coat of primer all as specified and directed by EIC. |
| 84 | M&L or preparation of new or previously untreated steel surface of any description not otherwise described , exc 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 85 | S&F for PVC coated fabric fencing mesh of size 50mmx50mm made of GI wire of dia 3 mm to achieve outer dianot less than 4 mm in required colour and shade fixed and placed on GI wire as in covering for tech bldgs to existing steel or new steel post complete all as specified and as directed by Engr-in-charge Please Enable Macros to View BoQ information |