| 1 | Taking down cement plaster including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed by Engineer - in - Charge. |
| 2 | M&L rendering 15 mm thick in CM 1:6 on brick masonary wall surfaces or on other than fair faces of brick masonry finished even and smooth witout using extra cement complete all as specified and directed. |
| 3 | M&L 15mm thick rendering in cement mortar 1:4 to on brick masonary wall surfaces or on other than fair faces of brick masonary fair finished without using extra cement with using water proofing liquid @ 0.15 Ltr per bag of cement complete all as specified and directed.(Note : Water proofing liquid shall be measured and paid separately) |
| 4 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises |
| 5 | Material and labour for non skid-ceramic tiles coloured of size area of each tile exc.0.06 sqm but not exc . 0.11 sqm (300 x 300 mm) X 6mm thick in floors etc, set & jointed in neat cement slurry and pointed in white or colours cement to match over and including 15 mm thick screed bed in Cement Mortar 1:6 complete all as specified and directed |
| 6 | Material and labour for glazed ceramic tiles coloured of size 350 x 450 x 7mm thick in walls etc, set & jointed in neat cement slurry and pointed in white or colours cement to match the colour of tiles over and including 10mm thick rendring in CM (1:4) complete all as specified and directed. |
| 7 | M&L for non skid cramic tiles colured of size area of each tile exc 0.18 sqm but not exc 0.38 sqm in flooor etc, jointed in neat cement slurry and pointed in white or colours cement to match complete all as specfied and directed over and including 15 mm thick screed bed in Cement Mortar 1:6 complete all as specified and directed |
| 8 | All as per item No 7 but in skirting, vertical surface dadoes and riser etcover and including 10mm thick rendring in CM (1:4) complete all as specified and directed. |
| 9 | M & L for Demolition of Cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as specified and directed. |
| 10 | M & L for PCC mix Type( D2 1:4:8 40 mm greaded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed. |
| 11 | Material and labour PCC 1: 2 : 4 type B-1 ( using 20mm graded crushed stone agg.) 40mm thick as in floor finishing surfaces of concrete topping even and smooth with using extra cement . |
| 12 | Supply only glass dividing strips ,3mm thick, 38 mm wide laid in position conforming to design pattern as approved by Engr-in-Charge. |
| 13 | M & L PCC mix type (1:1/2:3 using 20mm graded stone aggregate) as in flooring complete all specified incorporating an approval mentallic floor hardener 4% by weight of cement even and fair laid in panels finished (except metallic hardner),complete all as specified and as directed (Note: Metallic floor hardner will be measured & paid separataly) |
| 14 | M & L for 20mm thick wearproof topping as specified incorporating an approval mentallic floor hardener 4% by even and smooth without using extra cement (except metallic hardner), with spike rolling to surface or making expended metal whilst the concrete is green complete all as specified and as directed (Note:Metallic floor hardner will be measured & paid separataly) |
| 15 | Supply only metallic floor hardner complete all as specified and as directed |
| 16 | M & L for forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade 'A'. Thickness of concrete slab 100mm complete all as specified and as directed |
| 17 | M&L Hardcore of broken stones gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface including removal of existing loose soil complete all as specified and directed. |
| 18 | Demolition of Concrete is ground floors andy pavings n exc 15 cm thickness (below or above ground level)complete all as specified and directed by Engineer-in-Charge. |
| 19 | M& L 100 mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base floor / pavings complete all as specified and directed |
| 20 | M&L Sand filling under floors or in foundation including watering and consolidation complete all as spd |
| 21 | S&F rubber moulded decorative designed coloured machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment confirming to IS 15658-2006 of 80 mm thickness M-35 Grade with grey cement and pigment complete all as specified and directed |
| 22 | Material and labour for cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate for fixing hold fast, coping, cills and filling in pressed steel door frames including necessary form work and finishing the surfaces to match with existing, complete all as specified and directed. |
| 23 | Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed by Engineer-in-Charge. |
| 24 | M&L for brick work with fly ash bricks, straight or curved on plan exc. 6 m mean radius, built in CM (1:6) complete all as spd as directed |
| 25 | Taking down chowkats or frames not exceeding 1.5 Sqm each with shutter (without taking off shutter from the frame) removing from site complete all as specified and directed by Engineer-in-Charge. |
| 26 | Supply and fixing Pressed steel frame for doors of size 105 x 60 mm with one or more rebates one shop coat of priming and including necessary fixing lugs, hinges lock strike plate etc complete as specified made out of 1.25mm thick MS Sheet complete all as specified and as directed ( Note :- Disturbed portion of existing floor /wall / tile / plaster etc duing fixing of chowkhats shall be repaired to match with existing finish .Cost of the same will be included in this item ). |
| 27 | M&L for PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) for fixing of hold fast/filling pressed steel door frame including necessary form work complete all as specified and directed. |
| 28 | S&F 2nd class hard wood 35 mm thick factory made plain framed, panelled shutter (two panels) with lock rail and pannel of 12 mm veneered particle board with commercial veneering on both faces , the size of rail and stile as per Is- 1003 (part-I) kiln seasoned and chemically pressure treated complete all as specified and as directed |
| 29 | Supply and fixing aluminium handles extruded type of size 125mm, complete all as specified and directed. |
| 30 | Supply and fixing 150 mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete. |
| 31 | Supply and fixing 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed all as specified and directed. |
| 32 | Supply and fixing in repair 300 mm, mild steel ordinary rat tail rod pattern spring including roller and roller plate complete all as directed. |
| 33 | Dismantling of wall & celling boards (fiber pulp insulation etc) or insulation boards/slabs/blankets any thickness, including cover fillets. |
| 34 | Providing & fixing false ceiling at all heights with GRG (Glass Fiber Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanized iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 35 | Dismantling Plain or corrugated steel/ transluscent sheeting, any gauge, thickness, including Nainital or Similar pattern roof coverings etc complete |
| 36 | S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified . |
| 37 | S&F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified . |
| 38 | Dismanteling of wooden truss/ scanteling purlin rafter etc 40 Sqcm and over in section, in any position (framed work) all as specified and directed.. |
| 39 | S&F for Roof trusses (Framed), trussed, purlins, crane gantries, rails and fastening and heavy brackets framing(Beam, tee, angle, channel or flat section) including distance pieces, cleats, etc. Gde Fe 410-W (Gde-E-250) quality-A. |
| 40 | S&F of joist, channel, angle, flat iron or Tee sections, fixed independently with trusses connecting plates,such as in column etc complete all as specified and directed. |
| 41 | S&F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered , put together with glue, pinned at joints complete all as specified and directed. |
| 42 | Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed |
| 43 | M&L preparation of new steel surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 44 | Material and labour for Painting to new wood or wood based surfaces of any description not otherwise described over 10 cm in width or girth including preparation of surfaces, priming with pink primer (one coat) finished with two coats of synthetic enamel paint complete. |
| 45 | M&L prepring surfaces of wood and wood based materials, new or old of any description, not otherwise described and treated with one coat of creosote oil. |
| 46 | M&L for two coat OBD on newly plastered wall surface over including a coat of primer applied including a coat of 1mm thick wall care putty complete all as specified and directed by Engr-in-Charge. |
| 47 | M&L complete removal of existing treatment and for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed by Engr-in-Charge. |
| 48 | Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 mtr depth for foudations etc or for column footings, manholes etc not exceeding 10 Sqm on plan and not exc 1.5 mtr in depth and getting out in hard/dense Soil complete all as specified |
| 49 | Excavation in over area n exc 1.50 mtr depth in hard/dense Soi for foundation etc and getting out complete all as specified and directed. |
| 50 | Excavation in over area exc 1.50 mtr but n exc 3.00 mtr depthin hard/dense Soil for foundation etc and getting out complete all as specified and directed. |
| 51 | M&L for cement concrete type D-2 1:4:8 (using 40 mm graded crushed stone aggregates) as in foundations, filling and mass concrete complete all as specified and directed. |
| 52 | M&L for rendering 15 mm thick in Cement mortar (1:4) on fair faces of stone masonary/concrete surfaces finished even and smooth with out using extra cement complete all as specified and directed |
| 53 | M&L for Loose filling with shingle (River Bed aggregate )aggregates of gauge 80 to150 mm in soakage pits, soakage wells complete all as specified and directed |
| 54 | M&L for Loose filling with shingle or gravel (River Bed aggregate )aggregates of gauge 5 to 10 mm in soakage pits, soakage wells complete all as specified and directed |
| 55 | M&L for loose filling Coarse sand 1.5 to 2 mm in size under floor etc complete all as specified and directed |
| 56 | M&L for Reinforced cement concrete design mix M-25 (using 20 mm graded stone aggregates) in slabs supported on walls, beams & columns complete all as specified and directed. |
| 57 | M&L for mild steel TMT bars 5mm dia and overupto and including 10mm dia in stirrups, spaces and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for colomns hocking ends and binding with and including mild steel wire (annealed not less than 0.9 mm dia or securing with clips quality conforming to complete all as specified. |
| 58 | Formwork for Rough finished surfaces of concrete, to soffits and sides of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed |
| 59 | Returning & filling with excavated soil obtained from item No-1, in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thicks as in soil complete all as specified and directed |
| 60 | Removing excavated material (Hard dense soil) exc. 250 m but not exceeding 500 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 61 | M& L for Reinforced concrete pipes ,class NP-2 laid and jointed complete with collars of bore 200mm |
| 62 | M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate) concrete bed to drain pipe 200 mm bore including packing under and haunching against the sides of pipes after laid and tested complete all as specified and directed. |
| 63 | Material and labour for drilling of vertical bore well by rotary cum through direct hammering (DTH) technique in any type of strata consisting of following different dia drill bits in sequence from ground level as given below as per IS-2800 Part-I-1991 :- |
| 64 | (a) 300 mm dia drill bit from GL upto a maximum depth of 40 M. |
| 65 | (b) Supplying, assembling, jointing , lowering and fixing in position in the bore hole liner assembly, MS casing pipe of 5.4 mm thickness of 200 mm outer dia. Class 'B' conforming to IS - 4270-2001 (male / female) jointed and welded with coupler rings through out the circumference of pipe and externally painted with two coats of anti corrosive paint complete including providing pea gravel of 8 mm to 4.6 mm size for packing around the casing/ slotted pipe in bore well all as specified and directed by GE. Make Jindal/Tata |
| 66 | M & L PCC type C-2 1:3:6 (using 40mm graded stone aggt) in surface channel and drain. |
| 67 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concret using extra cement including forms, molds, mitred/stopped ends etc. |
| 68 | Add or deduct for each 25mm girth or part thereof over or under 30cm ditto |
| 69 | Taking down carefully copper/ aluminium point wiring ie. light, fan, socket or power/points complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and removing the items from site to store for taking credit (Credit for above items should be made as per conditions seperately) and making good disturbed surfaces of ceiling, walls, floors, etc complete all as specified and as directed. |
| 70 | Disconneting and taking down for main switch / MCB DBs including MCBs etc of any size and removing the items from site to store for taking credit (Credit for above items should be made as per conditions seperately) and making good distrbed surfaces to match with the existing surfaces of walls, floors etc complete all as specified and as directed. |
| 71 | Disconnecting electric connections and taking down for ceiling fans dismantling blades and removing fan and blades to store for keeping in safe custody for BER Board complete all as specified and as directed. |
| 72 | M & L in replacement of point wiring using proper colour coding complete all as specified with 1.5 sqmm PVC insulated FRLS/FR-LSZH unsheathed 1100 volts multistranded copper conductor two single core cable (Red and Black colour) confirming to IS 694:1990 Part-II with and including non metalic rigid PVC Conduit 25mm dia medium grade with all accessories including cutting chases pinning in, for concealed conduit wiring in wall/ceiling/floor/roof etc, making good of disturbed surface not exc 15cm girth, modular metal flush box or modular sunk pressed steel terminal box not less than 2mm thick, 50mm deep, covered with modular white cover plate (Outer cover) with frame (inner) including 1.5 sqmm PVC insulated FRLS unsheathed 1100 volts multistranded copper conductor one single core cable (Green colour) confirming to IS 694:1990 Part-II as continuous earth wire connected to common earth dolly all as specified and as directed for the following:- (a) One light/fan/exhaust fan point controlled by one modular switch. NOTE :- (i) Circuit conductor from MCB DB to Switch boards should not be less than 2.5sqmm. (ii) Modular white cover plate (Outer cover) with frame (inner) etc shall be measured and paid seperately under respective items. |
| 73 | Ditto- all as per above Sch \\"A\\" Item No. 70.00 but one 3 pin modular socket outlet 5 Amp on the same board with other switch. |
| 74 | Ditto- all as per above Sch \\"A\\" Item No. 70.00 but one 3 pin modular socket outlet 5 Amp independent board. |
| 75 | Ditto- all as per above Sch \\"A\\" Item No. 70.00 but one 3 pin socket outlet 15 Amp independent board with 2.50 sqmm PVC insulated FRLS unsheathed 1100 volts multistranded copper conductor single core cable (Red, Black and green colour) confirming to IS 694:1990 Part-II. |
| 76 | S & F in replacement of Modular white cover plate with frame 1 Module complete all as specified and as directed. |
| 77 | S & F in replacement of Modular white cover plate with frame 2 Module complete all as specified and as directed. |
| 78 | S & F in replacement of Modular white cover plate with frame 3 Module complete all as specified and as directed. |
| 79 | S & F in replacement of Modular white cover plate with frame 4 Module complete all as specified and as directed. |
| 80 | S & F in replacement of Modular white cover plate with frame 6 Module complete all as specified and as directed. |
| 81 | S & F in replacement of Modular white cover plate with frame 8 Module complete all as specified and as directed. |
| 82 | M & L in replacement of modular switch, 1 way 6 Amp, 1 module |
| 83 | M & L in replacement of modular switch, 1 way 16 Amp, 1 module |
| 84 | S & F in replacement of modular socket 6Amp, 2/3 pin, combined 2 module. |
| 85 | S & F in replacement of modular socket 6A/16A, 2/3 pin combined 2 module. |
| 86 | S & F in replacement of ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body of size. |
| 87 | S & F in replacement of Lamp holder (Batten/Angle) PVC/Polycarbonate type with back plate for batten/angle fittings, complete all as specified and directed. |
| 88 | S & F in replacement of Lamp LED ADORE PLUS 1 x 9 Watts, CDL, 3 Star rating, heat sink white with Polycarbonate diffuser, B-22 base cap, retrofit type, 220/230 volts, complete all as specified and directed. |
| 89 | Supply and fixing in replacement of LED lights fitting 1x 20 Watts (T-8), 4 feet long, 220V, AC, decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, prewired complete with two Nos of PVC box of size 75x75x20mm for mounting light fittings, complete all as specified and as directed. |
| 90 | S & F in replacement of LED light fitting 1x9W/1X10W Bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size with LED Lamp 1 X 9/10watts, complete all as specified and as directed. |
| 91 | S & F in replacement ofSupply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. |
| 92 | Supply and fixing in replacement of Ceiling fan 1200mm sweep, complete with blades, down rods, Electronic regulator and accessories, 230 V, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including connecting up with three core flexible copper conductor cable for suitable size, complete all as specified and as directed. |
| 93 | S & F in replacement of sheet metal enclosures MCB SPN DBs 8 Way, 240 Volts, 50Hz, AC, double door suitable for flush mounting and surface mounting with 200 Amp copper bus bar for phase, including connection, testing and making good the disturbed surfaces complete all as specified and as directed. |
| 94 | S & F in replacement of miniature circuit breaker (MCB), Single Pole & Neutral 40 to 63 Amp, rating 240V, 10 KA current carrying capacity, 'C' curve fixing in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed. |
| 95 | S & F in replacement of miniature circuit breaker (MCB), Single Pole 6 to 32 Amp, rating 240V, 10 KA current carrying capacity, 'C' curve fixing in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed. |
| 96 | S & F in replacement of GI Bracket made out from GI pipe 25/32mm dia bend to shape as required, 1.2Mtr long fixed on wall with flat iron clamps of size 25 x 4mm - 2 Nos with the help of bolts, nuts, washers etc for fixing of security light fitting, complete all as specified and as directed. |
| 97 | Taking down old service connection/UG Cable removing of site complete all as directed. |
| 98 | Supply and laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size 10 sqmm x 2 core laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles etc, complete all as specified and as directed. |
| 99 | Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth for laying of electric cables or water pipe etc, not exc 10 sqmm on plan and not exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge. Note : Rates includes removing of paver blocks carefully and stack properly for refixing after laying of cables . |
| 100 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil. |
| 101 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting pointcomplete all as specified. |
| 102 | Material and labour for river washed and screened, dry sand for cushioning of cable in trenches for cable protection including spreading, leveling and hand punning complete all as specified in SSR Part-I and as directed. Note :- Only compacted thickness of sand will be measured and paid separately. |
| 103 | Supply, laying un-reinforced precast concrete cable cover class LV type 1 flat size 250mm x 150 mmx 40 mm. |
| 104 | Material and labour for Horizontal directional drilling (HDD) is a streeable trenchless method of Laying (installing) underground cables in a shallow arc along a 40mm/50mm bore path by using a surface-launched drilling rig, with minimal impact on the sorrounding area complete all as specified and as directed by Engr-in-charge. |
| 105 | M&L for GI pipe ,light grade 40mm dia for road crossing of cable for cable protection laid in trenches or above ground surface, complete all as specified and directed. |
| 106 | M & L in replacement Earth continunity conductor or main earth ing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of 4.00 mm dia GI or steel wire all as specified. |
| 107 | M&L for Earthing complete with galvanized iron earth plate electrode 600 x600x6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.6 meter below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts check nuts galvanized iron or steel all as shown in Electrical plate No. 3 of SSR PT- I testing on completion with & incl. 15 mm bore light grade GI protection pipe 7.5 mtr long for earth lead, PCC (1:3:6) pit with pre cast RCC (1:2:4) type B1 cover slab with one handle made out of 8mm dia round bar, watering arrangement with funnel, wire mesh 20 mm bore light grade GI pipe, common salt & charcoal alternative layers, necessary excavation earth work, including earthing test point all as specified or indicated including testing on completion and as directed. |
| 108 | Supply, laying, conecting and testing of ISI marked GI steel water tubing medium grade Including S & F all fittings and fixed complete to walls and celling or laid in floors complete of following sizes :- |
| 109 | (a) 50 mm bore |
| 110 | (b) 25 mm bore |
| 111 | S & F 25 mm bore Gun metal globe valve or gate valve with iron wheel head , screwed both ends with 01 No union for iron pipe heavy duty with ISI marked all as specified and directed. |
| 112 | S & F 50mm bore Gun metal globe valve or gate valve with iron wheel head, screwed both ends with 01 No Union for iron pipe heavy duty with ISI marked all as specified and as directed. Please Enable Macros to View BoQ information |