| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as spd/directed by Engr-in-Charge. |
| 2 | M& L for vitrified tiles double charge/dark shade/ wooden shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6, complete all as specified and as directed. |
| 3 | M& L for vitrified tiles double charge/dark shade/ wooden shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm n.exc 1 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6, complete all as specified and as directed. |
| 4 | All as per above but on vertical surfaces including 10mm thick screed plaster in CM 1:4 complete all as specified complete all as specified and as directed. |
| 5 | Dismantling wall and ceiling boards (fibre, plup, insulation, etc) or imsulation boards/slabs/blankets,any thickness, including cover filltes |
| 6 | S&F 12mm thick water proof gypsum board false ceiling raised and sunk incl jointing compound and tape, including two coats of OBD over a coat of primer over smooth putty finish with GI grid 80x26x0.5mm ceiling section at 457mmc/c, 15x45x15x0.9mm intermediate channel at 1220mm c/c, 20x28x30x0.5mm perimeter channel, 25x10x0.5mm ceiling angle at1220mm c/c, 9x10xx28x0.5mm shadow line bead and 2.64mm connecting clip, soffit cleat etc complete all as specified and directed by Engr-in-Charge. |
| 7 | S&F 4 mm thick non asbestos fibre cement building boards (E- Board) including 605 x 605 mm GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30 mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre / intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (Not exc 1.2m length) of 0.55 mm thick ness having kurled web of 50mm and flanges of 26 mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre including hangers 6mm dia gI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5 mm dia 40mm long compelte all as specified. |
| 8 | S&F 12mm thick WPC Charcoal louvers (premium quality) of any design and pattern including clips any type beading etc fixed on wall/ceiling all as specified and directed by Engr-in-charge. |
| 9 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 Sqm but n.exc 4 Sqm each complete all as specified and directed. |
| 10 | S&F 12 mm thick toughened glass door shutter/partition of opening size less than 4.00 Sqm in single leaf with frosted film incl logo and letter printing and pivot at top, fancy type glass handle of size not less than 300 mm on both sides of shutter to match with colour of glass shutter with suitable locking arrangement and all necessary fitting complete all as specified and directed. |
| 11 | M&L for Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover,governing pivot made of brass,other parts made of mild steel heavy duty and fixed complete all as specified and directed.make-ozone |
| 12 | Demolition of brick work of any type built in cement mortor etc complete all as specified |
| 13 | M&L for brick work built in cement and sand mortar 1:6 with sub class 'B' old size bricks straight or curved on plan exceeding 6m means radius complete all as specified. |
| 14 | Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc all as directed. |
| 15 | M&L rendering 15mm thick in cement plaster 1:6 on surfaces fair faces of brick work and surface finished fair and even complete all as specified and as directed. |
| 16 | M&L for 5 mm thick rendering in cement mortar 1:3 on concrete surfaces as on ceiling and finished fair and even complete all as specified and directed. |
| 17 | M&L rendering 15mm thick in cement mortar in 1:4 on fare face of brick work or concrete surfaces even and smooth without using extra cement complete all as specified |
| 18 | M&L for preparation of new/old plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade over a coat of primer complete all as specicified. |
| 19 | M&L for preparation of new/old plastered surfaces of ceiling and applying two coats of oil emulsion distemper (OBD) of approved shade over a coat of primer complete all as specified. |
| 20 | M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint over a coat of alkali resistant primer of approved shade/tint complete all as specified. |
| 21 | M&L for providing and injecting chemical emulsion for Post Constructional Anti termite Treatment along internal wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sqm of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc.complete all as specified and directed. |
| 22 | Dismantling of CGI/ Galvalume/ PGI sheets in roof coverings complete all as directed. |
| 23 | S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws & EPDM washer as specified |
| 24 | Only refixing of pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed. |
| 25 | S&F for prelaminated galvalume aluminium zinc coating GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 26 | S&F mild steel section such as Roof trusses (framed), trussed, ladder, rafter, purlins, crane antries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc using ERW or induction butt welded tubes conforming to IS 1161-1979 Fe-450(Gde E-250)complete all as specified and as directed. |
| 27 | Only Refixing of Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. |
| 28 | S&F mild steel section such as post, single stanchions, built up of one beam or channel section with flange plates, caps,bases. splices, angle brackets,cleats and other connections conforming to IS 1161-1979 Fe-450(Gde E-250)complete all as specified and as directed. |
| 29 | S&F MS plate as rest plate of truss forming hole for anchor bolt without any attachement complete all as specified and as directed. |
| 30 | M&L for preparation of new surfaces of steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of red oxide complete all as specified. |
| 31 | S&F IInd class hard wood plain, soild chowkhats and frames wrought,framed rebated on the solid rounded or chamfered put together with glue pined at jints all as specified and direcetd at site |
| 32 | M&L 12 mm thick plywood grade BWR type BB, fixed with screw to timber frame work block board interior grade having both sides commercial faces fixed with screws to timber frame work complete all as specified and directed. |
| 33 | S & F 0.9 mm thick Decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructionas complete all as specified and directed. |
| 34 | S & F Anodised aluminium frame work for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified. |
| 35 | S & F Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges anodised aluminium snap beading screws etc. complete all as specified. |
| 36 | M & L 4.8 mm thick sheet glass, ordinary quality in squares exc. 0.5 Sqm in each pane |
| 37 | S&F of hallow strip prelaminated PVC Wall Linning consisting of 5mm thick any color/desigened PVC sheet inclusive of nails and fixing at site on wall and PVC L-beading at top of wall lining,corner of wall,opening eadge of door & windows matching with panel as per specifications complete all as specified and as directed. |
| 38 | S&F 5 mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing . |
| 39 | Dismantling PVC water tanks and removing for capacity exceeding 500 litres & not exceeding 1000 litres etc., all as directed. |
| 40 | S&F 1000 Litre capacity Rotational moulded polyethylene water storage tanks triple layered in white colour (cylindrical, vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete, all as specified and directed. |
| 41 | S&F 20 mm ball valve high pressure of PTMT with apoxy coated aluminium rod and high density plastic ball screwed for iron pipe, all as specified. |
| 42 | S&F in repair gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20 mm bore, all as specified and as approved by GE/ Engineer-in-Charge. |
| 43 | S&F in repair 15 mm bore stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed |
| 44 | S&F in repair vitreous china floor/wall hung WC with flushing cistern, UF seat cover, hinges, accessories set of size 375 x 650 x 800/370 x 645 x 810 mm fixed to wall/floor with P/S trap complete as per manufacture's instructions complete all as specified and directed. |
| 45 | S & F in repair PVC low level flushing cistern of 10 ltrs capacity with dual push button inclusive of brackets and PVC bend long type and connection to flush pipe of any size and pattern with inlet ball valve float and handle complete of approved |
| 46 | S&F in repair vitreous china wash hand basin, pedestal type white, flat back of size 550mm x 400mm with & including a pair of cast iron brackets embedded in PCC 1:3:6 type C1 blocks of size 10x7.5x15cm, 32 mm dia PVC waste pipe and 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, (excluding tap, waste chain & plug), complete all as specified. |
| 47 | S&F in repair 15mm bore chromium plated Pillar cock screwed down high pressure, with or without lettered Hot ot Cold with long screwed shanks and flynuts screwed for iron pipe complete all as specified. |
| 48 | S&F in repair hand shower (Health faucet) with 1 Mtr flexible tube with wall hook bracket etc complete set of superior quality all as specified and directed. |
| 49 | S&F in repair CP shop dish fancy type fixed with SS screw on wall etc all as specified and directed. |
| 50 | S&F in repair toilet paper holder CP fixed complete all as specified and directed. |
| 51 | S&F in repair PVC bath cabinet with 4 mm thick looking mirror of overall size 560 x 410 mm fixed on wall etc complete all as specified and directed. |
| 52 | S&F in repair CP brass tubular towel rail, 20mm dia, ‘D’ type, 60cm long between flanges, fixed to PVC rawl plugs with chromium plated brass screws, complete all as specified. |
| 53 | S&F in repair glass corner self assembly, fancy type, made of 6 to 7mm thick sheet toughened glass of size 250x250mm, fixed with CP brackets, complete, all as specified and directed. |
| 54 | Dismanntling of stone slabs and tiles of any description or thickness in floors, platform, aprons etc., laid, bedded and pointed, in any mortar complete all as specified & directed. |
| 55 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) |
| 56 | M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub-base. complete all as specified & directed. |
| 57 | M&L for 40mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in sub-base. complete all as specified & directed. |
| 58 | S&F of ACP board of 4mm thick Cladding including alm beedings over the wall/ceiling complete all as specified & directed. |
| 59 | M&L for preparation new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over with 1-2 mm thick birla white care puty on wall etc complete all as specified & directed. |
| 60 | M&L for preparation and complete removal of existing treatment from old plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over with 1-2 mm thick birla white care puty on wall etc complete all as specified & directed. |
| 61 | Excavation in post holes ( or similar holes) each n.exc 0.50cum and getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers n.exc 25cm, watering and removing surplus soil to a distance n.exc 50mtr and making good surface in soft/loose soil complete all as specified and as directed. |
| 62 | M&L for PCC 1:3:6 type C-2 (40mm graded stone aggregate) as in posts etc all as specified and as directed. |
| 63 | S&F 110mm PVC (SWR) pipes single socketed in inany length with rubber ring jointed fixed to wall 110mm bore, complete all as specified asnd directed. |
| 64 | S&F 110mm bore PVC (SWR) bends, any radius complete all as specified and directed. |
| 65 | M&L for Chequered cement concrete tiles 30cm x 30cm x 20mm thick, set, jointed and pointed in neat cement slurry in floors over 20mm thick screed bed in CM 1:6 , cutt and polished complete as specified and as directed |
| 66 | M&L for providing, cement concrete Type B1 1:2:4 (20 mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed. |
| 67 | S&F powder coated(min thickness of powder coating 50 micron) anodised aluminum window shutter three track sliding type, section having frame size bottom with outer 92x45.5x1.5mm (section code 20617) , top and side 92x31.75x1.5 (section code 20831) & aluminum section of shutter top and bottom size 40 x 18 x 1.5 ( section code 20736) , interlock size 40 x 18x 1.45 (section code 20737), side/ middle size 40 x18 x1.55, (section code 20738) including necessary joining cleats, glazing clips rubber backing, anodised aluminum snap beading screw, anodised aluminum fitting complete as per site requirtement glazing by using 5mm thick plain sheet glass and ss wiremess of dia 0.36mm and aperture 1.4mm thick all as specified and directed. Note- 1. Glazed shutter glass thickness not less than 5mm and ss wiremess shutter with ss wiremesh as approved by GE is also included. No payment will be made separately.2. No extra payment will be made for section profiles of higher sizes. |
| 68 | S&F 50 micron powder coated for aluminium anodized grill size 6mm dia of aluminium bar mesh size75mmx75mm and fixed to aluminium window ventilator complete, all as specified and directed. |
| 69 | S & f powder coated aluminum ventilator ( louvers) shutter with 3.8 mm thick plain / tinted glass consisting of frame of size 63.5 x 44 and shutter sections weighing not less than 0.55 kg/m with locking arrangement as approved fixed including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fittings with stainless steel wiremesh of 0.36mm including necessary fixing arrangement complete all as specified and directed |
| 70 | Taking down carefully copper/aluminium point wiring ( light, fan, socket , bell or power) complete including DBs, submain,cables etc all as specified and directed by Engineer-in-charge. |
| 71 | Taking down carefully Ceiling fan/wall fan/Exhaust fan/Geysers complete and handover to Yard-I after 2 coat of spray painting with enamel paint all as specified and directed by Engineer-in-charge. |
| 72 | Taking down carefully any Light fittings/fixtures any size complete including all (electrical fittings & fixtures etc) all as specified and directed by Engineer-in-charge. |
| 73 | Material and Labour for point wiring complete with 1.5 sqmm (nominal area) FRLS grade PVC insulated, unsheathed multi stranded copper conductor single core cable 1100 volts grade in and including PVC conduit with accessories including 1.5 sqmm FRLS grade PVC insulated unsheathed stranded copper conductor cable for earth continuity conductor and connected to common earth dolly for One light/Ex-fan point controlled by one switch 5Amps SP all as specified and directed.Note :- Sunken box/cover plate for modular switches, sockets etc will be measured and paid seperately under relevant items and blank plate required if any will be deemed included in the item rate.and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall all as specified. |
| 74 | All as per Item No 4 hereinbefore but for One 5 A socket outlet on same Board all as specified and directed. |
| 75 | All as per Item No 4 hereinbefore but for One 5 A socket outlet on independent Board all as specified and directed. |
| 76 | All as per Item No 4 hereinbefore but point wiring complete with 2.5 sqmm for 3 pin 5/15 A socket outlet on independent board including 2.5 sqmm FRLS grade PVC insulated unsheathed stranded copper conductor cable for earth continuity conductor all as specified and directed. |
| 77 | Supply and fix frame plate with match cover( Coloured plate matching with the wall panelling) twelve module all as specified and directed. |
| 78 | Supply and fix frame plate with match cover ( Coloured plate matching with the wall panelling) six module all as specified and directed. |
| 79 | Supply and fix frame plate with match cover ( Coloured plate matching with the wall panelling) three module all as specified and directed. |
| 80 | Supply and fix terminal box suitable twelve modular plat of size 75X75x50 mm including cutting, grooving and plastering etc. all as specified and directed. |
| 81 | Supply and fix terminal box suitable six modular plat of size 75X75x50 mm including cutting, grooving and plastering etc. all as specified and directed. |
| 82 | Supply and fix terminal box suitable three modular plate including cutting, grooving and plastering etc. all as specified and directed. |
| 83 | Supply and fix Rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.PVC pipe 40 mm dia for protection of cables all as specified and directed by Eng-in-Charge |
| 84 | Supply and fix TV Socket 1 Module Modular all as specified and directed. |
| 85 | Supply and fix Telephone socket 1 Module Modular all as specified and directed. |
| 86 | Supply and fix Modular switch one way 6A 230V AC 50 HZ SP one module all as specified. |
| 87 | Supply and fix Modular switch one way 16A 230V AC 50 HZ SP one module all as specified. |
| 88 | Supply and fix Modular socket 2/3 pin combined 6A 230V AC 50 HZ SP two module all as specified. |
| 89 | Supply and fix Modular socket 6A/16A 2/3 pin combined 230V AC 50 HZ SP two module all as specified. |
| 90 | Supply and fix MCB SP 230V, 6-32 Amps capacity all as specified and directed. |
| 91 | Supply and fix MCB DB SPN 8 way double door type suitable for TP/FP including necessary dummy plate and necessary civil works all as specified and directed. |
| 92 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning 40 to 63 Amp capacity all as specified and directed. |
| 93 | Supply and fix Modular Regulator 230V AC 50 HZ SP two module all as specified. |
| 94 | S&F modular bell push single pole 1 module 6 Amp, 240 volt all as specified. |
| 95 | S&f call bell , ding dong / musical AC single phase 230 volts all as specified. |
| 96 | S&F Ceiling rose PVC polycarbonate all as specified and directed. |
| 97 | Supply and fixing recess mounting LED light fitting 2'x2' luminaire architectural recessed luminaire( White/Warm white colour) with CRCA housing and Molded PC diffuser with an unique angular optics for making the illumination easy on eyes for light comfort in office areas with UGR<=19. The luminaire should have a color consistency SDCM< 5, CRI > 80 and choice of CCT: 5700K. Luminaire shall be designed to emit at least 3000 lumens and an efficacy of atleast 120Lm/W and maximum system wattage of 36 Watt, designed for ambient temp 45 deg C. The metallic electronic driver shall have a power factor >0.95, THD <10%, 4KV internal surge protection and the Ripple factor should be <5% to minimise the Flicker and Stroboscopic effect and The driver should be complied with Fixed output/DALI/POE version and Fixture should have an operating voltage range of 140-270VAC incl It should have over voltage protection @320V Cut-off with auto restart features all as specified and directed. |
| 98 | Supply and fixing round shape 15watt watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by engineer in charge |
| 99 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10/12 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & directed. |
| 100 | S & F decorative wall mounted fancy light fitting made up of brass rubi lamp brand Single handed including of bulb of 9-15 watts covered by glass complete all as specified. |
| 101 | Material and Labour for Submain wiring with 2 runs of FRLS grade PVC copper conductor cable 4 sqmm, multistranded along with FRLS grade PVC insulated copper earth continuity conductor 4 Sqmm drawn through and including PVC Conduit pipe 25 mm dia including taking down of existing submain wiring and cutting chasing and making good to distrubed surface with all fittings all as specified and directed. |
| 102 | Material and Labour for Submain wiring with 2 runs of FRLS grade PVC copper conductor cable 6 sqmm, multistranded along with FRLS grade PVC insulated copper earth continuity conductor 6 Sqmm drawn through and including PVC Conduit pipe 25 mm dia including taking down of existing submain wiring and cutting chasing and making good to distrubed surface with all fittings all as specified and directed. |
| 103 | Material and Labour for Submain wiring with 4 runs of FRLS grade PVC copper conductor cable 10 sqmm, multistranded along with FRLS grade PVC insulated copper earth continuity conductor 10 Sqmm drawn through and including PVC Conduit pipe 25 mm ncluding taking down of existing submain wiring and cutting chasing and making good to distrubed surface with all fittings all as specified and directed. |
| 104 | Supply and fixing ceiling fans remote operated, led down lights on rotor complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) with copper winding incl remote all as specified and directed. Note:- Down rods of suitable length( 4feet,5 feet or 6 feet) is incl in the item rates and no extra payment will be done to the contractor for the same. |
| 105 | Supply and fixing of wall fan of 300 mm sweep, 220 - 240 volts, AC, 50 Hz 1330 RPM, 55 Watts power input, air delivery 65 Cum/min with all accessories complete all as directed by Engineer - in - charge. |
| 106 | Supply and fix in replacement single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one 20 amps SPN MCB all as specified and directed |
| 107 | Taking down any type of AC and refixing after panelling and other works incl charging of any type of gas suitable for AC, servicing all as specified complete.Note- Any extra length of copper pipe,drain pipe is incl in the item rate. |
| 108 | Material and labour Earthing complete with galvanized steel earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanized earth wire of size 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 connected to earth testing point including necessary excavation, earth work, PCC pit ,RCC cover 1:2:4 B1 with 8 mm dia MS rounds 1.5 kgs, funnel ,watering pipe etc. all specified and directed including testing on completion all as specified and directed. |
| 109 | Cutting chases in concrete wall/stone for laying PVC conduit and making good to facings where required and pointing in cement mortar 1:3, and making good, cutting not exc 20 cm girth and matching wall color. |
| 110 | Supplying /Fixing of PVC copper conductor cable of size 1.5 sqmm, 3 Core PVC insulated on wall/roof etc complete all as specified and directed. |
| 111 | Supply and fixing of wall/surface mounted integrated batten LED light luminaire of 4ft length with a system wattage of 20-22W with a nominal system lumen output of 2000-2200 lumens and a minimum system efficacy of 100Lm/W. CCT shall be 6500K and CRI ≥ 80. Housing shall be extruded aluminimum with powder coating & with IP20 protection, The luminaire shall meet IP20 rating with surge protection of 2.5KVA, THD ≤10% and PF ≥ 0.95, complete all as specified and directed. |
| 112 | Dismantling and shifting of split type AC 1.5/2.0 TR Capacity at given location including servicing of complete AC (indoor/outdoor unit) making copper tubes connections,recharging of refrigerant (required quantity) complete for making serviceable the existing Air conditioners. |
| 113 | Supply and fixing of copper tubing of size 5/8 inches with suitable size of insulation complete all as specified |
| 114 | Supply and fixing of copper tubing of size 3/8 inches with suitable size of insulation complete all as specified Please Enable Macros to View BoQ information |