| 1 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil : |
| 2 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of Soil @60% |
| 3 | Ordinary Rock @40% |
| 4 | Soling-Dumping of stone including cost of stone |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundation,Plinth Beam, footing bases of column. |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for: Columns, pillars, piers, abutments, posts and struts. |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platforms. |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for: Slab Edge Shuttering - Under 20cm Wide |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for: Stairs (excluding landings) except spiral staircases. |
| 13 | Random Rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with: Cement mortar 1:6 (1 Cement : 6 coarse sand) |
| 14 | Coursed rubble masonry with hard stone (first or second sort) in superstructure above plinth level and upto floor five level. Masonry work (first sort), in cement mortar 1:6 (1 cement : 6 coarse sand) |
| 15 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, column, pillars, piers, abutments, posts and struts etc. upy floor five level excluding cost of centering, shuttering, finishing and reinforcement: (1:1.5:3) 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 16 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 5.3.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 17 | Steel Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. (Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 18 | Providing & fixing upto floor five level compressed stabilized earth blocks (CEB) made an appropriate mix of dry inorganic subsoil, non-expansive clay, sand, and aggregate with 5% cement as stabilizer, in mud mortar, including cost of materials complete. |
| 19 | Providing & fixing upto floor five level precast cement concrete solid blocks including hoisting and setting in position in cement mortar 1:3 (1cement:3 coarse sand), cost of required centring, shuttering and curing complete 1:3:6(1 cement :3coarse sand :6graded stone aggregate 20 mm nominal size) |
| 20 | WALL PLASTER - EXTERIORCEMENT PLASTER (IN FINE SAND) 12mm Cement plaster of mix:1 : 4 ( 1 cement : 4 fine sand) |
| 21 | WALL PLASTER - INTERIORCEMENT PLASTER (IN FINE SAND) 12mm Cement plaster of mix:1 : 4 ( 1 cement : 4 fine sand) |
| 22 | 6mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 23 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 24 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface Water thinnable cement primer. |
| 25 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 26 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.13.88.1 1 mm thick |
| 27 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer. |
| 28 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 29 | Providing and fixing 100mm Pine wood plain lining tongue and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface. 10mm thick |
| 30 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, M.S. tube |
| 31 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished 40 mm thick with 20 mm nominal size stone aggregate |
| 32 | 20mm cement plaster finished with a floating coat of neat cement of mix :1 : 3 ( 1 cement : 3 fine sand) |
| 33 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and onforming to IS: 15622, Shade and Texture as approved by Architect In charge. Laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of tile 600x600 mm |
| 34 | LAMINATED FLOORINGProviding and fixing Interlock Laminate (AC-4) on floors including necessary fittings and accessories like base foam and edge beading.All Job Complete. |
| 35 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average)thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete asspecified and as directed by the Engineer-in-Charge. Polished Granite stone slab with Shade as approved by Architect in charge. |
| 36 | Providing and laying Localy Available Yamangs stone flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 37 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Second class kail wood. |
| 38 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Second class kail wood 35 mm thick shutters. |
| 39 | Float glass panes9.7.7.1 4 mm thick glass pane (weight not less than 10kg/sqm). |
| 40 | Providing and fixing bright finished brass handles with screws etc. complete: 100 mm |
| 41 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 42 | Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc complete. 250x10 mm |
| 43 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of leverhandles of approved quality with necessary screws etc. complete. |
| 44 | Providing and fixing ISI marked, IS : 1341, M.S. heavy weight butt hinges with necessary screws etc. complete : 125x90x4.00 mm |
| 45 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. (a) Twin rubber stopper |
| 46 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.Of make Godrej, Dorma or equivalent. |
| 47 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequenceas detailed below:1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3.On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/ grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in- Charge. (Final coat to be done in 1 or 2 layers without gap of time.) Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm)made of (big series)frame 67 x 60 mm & sash / mullion 67 x 80 mm both havingwall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead ofappropriate dimension. (Area of window above 1.50 sqm). |
| 48 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing |
| 49 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceilingwith dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, towhich the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimetre channels 0.5 mm thick 27 mm high having flanges of 20mm and 30 mm long, the perimetre of ceiling fixed to all/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimetre channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges ofthe board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimetre channels suitably fixed, all complete asper drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks). |
| 50 | Providing and fixing traditionally carved wood work (Shingstak) over doors and windows including all accessories as per the direction of the Engineer in-charge, complete with; Budloo wood |
| 51 | Dry random rubble masonry with hard stone in foundation and plinth: 7.3.1 With bond stone. |
| 52 | Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) :Medium shade pigment using 50% white cement, 50% ordinary cement |
| 53 | Providing and applying polyurethane insulation foam in the exterior cavity walls , having an eveen thickness of 3 inches.All work complete |
| 54 | Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45 Kg per square metre of area for each course, second course of roofing felt type 3 grade-I (Hessian based self finished bitumen” felt) and fourth and final course of stone grit 6mm and down size or peasized gravel spread at 6 cubic diameter per square metre including preparation of surface but excluding grading complete with : Bitumen felt (Hessian base) type 3 grade I conforming to IS : 1322. |
| 55 | Design, manufacture, supply, installation, testing, commissioning, approvals (statutory or otherwise) and handing over in satisfactory working conditions of Elevators with directional control of cars (as required) with Automated Rescue Devices Design with ACVVVF control with stainless steel hair line finish enclosures, automatic centre opening car & landing doors, including the cost of providing 4 weeks satisfactory trial operation and testing at full design load and safely checks for sudden breaks, speed, etc. as directed and including the cost of providing free comprehensive maintenance service for 12 months after final virtual completion and satisfactory handingover, complete as per specifications as required and as below :Gearless, Machine Room less Elevator traction lift with variable voltage variable frequency drive having a speed of 1.25 metre/ sec and Microprocessor based control suitable for operation on 415 V, 50 Hz, 3 phase A.C. electric supply as required and as per specifications and details given in Annex A 8 Passenger(544Kgs) lift, Travel Height 16.00 Mtr approx, 5 Stops ,speed-1.25MPSwith SS Vandal proof with full framed glass door in front side and as per design discussed & to be got approved in GAD, full collective operation, simplex,415volts,+/-10%,3phase,50Hz ac supplyCar enclosure:Full infra red screen sensor,SS railing, as per our technical specifications. Make OTIS,Schindler or equivalent |
| 56 | Providing and fixing Precast Concrete Kerb Stone blocks of size 300x300x100mm as per sample approved. |
| 57 | Providing and Fixing of Acrylic sign board with lettering)The height ,written text, colour,font and size of board to be decided as per architect in charge . To be installed with necessary signage lighting and wiring.All work complete. |
| 58 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 59 | Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gram/m2 |
| 60 | Providing and fixing plained eaves boarding.2nd class kail wood.300x40 mm (nominal size) |
| 61 | Providing and fixing up to floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc., including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required Centering complete. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size) |
| 62 | Designing, Supplying, Assembling / fabricating, Installation, finishing, testing and fixing in position of Concrete Jaali Blocks of approved make, color, shape, size & design to be installed in the External Elevation,complete to the satisfaction of the Architect & Engineer in charge and as per directions . |
| 63 | Providing and laying 60mm thick factory made cement in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 64 | Carriage of material by MT from source to site of work including loading, unloading complete job.Cement & Steel -----------20 Km |
| 65 | Sand ------20Km |
| 66 | Stone Aggregate---20 km |
| 67 | Stone Blocks -------20 Km |
| 68 | Earth-------20 Km |
| 69 | Boundary Wall items:Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:All kinds of soil |
| 70 | Soiling : Dumping of Stone Including Cost of stone |
| 71 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 72 | Centering and shuttering including strutting, propping etc. and removal of form for:Footing For Column. |
| 73 | Centering and shuttering including strutting, propping etc. and removal of form for:Foundation Tie Beam. |
| 74 | Centering and shuttering including strutting, propping etc. and removal of form for:Column + Neck Column. |
| 75 | Random Rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with:Cement mortar 1:6 (1 Cement : 6 coarse sand) |
| 76 | Providing & fixing upto floor five level precast cement concrete solid blocks including hoisting and setting in position in cement mortar 1:3 (1cement:3 coarse sand), cost of required centring, shuttering and curing complete 1:1½:3(1 cement :1½ coarse sand :3 graded stone aggregate 20 mm nominal size) |
| 77 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, column, pillars, piers, abutments, posts and struts etc. upy floor five level excluding cost of centering, shuttering, finishing and reinforcement: (1:1.5:3) 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 78 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. (Thermo-Mechanically treated bars.) |
| 79 | CEMENT PLASTER (IN FINE SAND) 12mm Cement plaster of mix:1 : 4 ( 1 cement : 4 fine sand) |
| 80 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 81 | EXTERIOR FINISHINGFinishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 82 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. |
| 83 | Providing and fixing up to floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc., including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required Centering complete. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size) |
| 84 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including Hot finished seamless type tubes |
| 85 | Carriage of material by MT from source to site of work including loading, unloading complete jobCement & Steel -----------20 Km |
| 86 | Sand ------20Km |
| 87 | Stone Aggregate---20 km |
| 88 | Stone Blocks -------20 Km |
| 89 | INTERNAL PLUMPING ITEMS:SANITARY FIXTURES & CP FITTINGS:Supply and install white vitreous china Rimless single piece water closet (European type) with Soft close slim seat cover (size: 655mmx355mmx720mm), and CP flush bend with fittings and C.I. brackets, 40mm flush bend, S Trap 220mm, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required(Make: Jaguar Cat No.CNS-WHT-851S300SPP, Essel Cat No. 77091653, or equivalent) |
| 90 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :17.1.1 White Vitreous china Orissa pattern W.C. pan of size 590x445mm with integral type foot rests.(Make Essel Cat No. 75013010 , Jaguar CatNo. CNS-WHT-OP01 or Equivalent) |
| 91 | Providing and fixing of white vitreous china European raised seat water closet for handicap toilet including providing & fixing CP bolts, nuts, fisher/anchor bolt are required for hangong of WC, exposed low volume compatiable dual flush chinaware cistern with CP bolts, nuts, supporting arrangements, bakelite/ poly propylene seat & cover with CP hinges & rubber buffers, WC pan connector (straight/offset type Macfit single body push fit type WC pan connector with factory supplied spring loaded seal guard with integral single mould sealing fins made of flexible EVA body, including bush/adaptor for use with C.I./PP/uPVC Pipe as supplied with the pan connector), wall mounted 32 mm dia seamless stainless steel tube coated with nylon non-slip gripping surface hinged Hand Rail 750 x 100 mm complete with all accessories. Including cutting & making good the walls & floors wherever required. |
| 92 | Supply and install white vitreous china urinal with spreader of size 355x340x535mm approx. having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer. (Make:Jaguar Cat No. URS-WHT-13261H, Essel Cat No. 73011010, or equivalent) |
| 93 | Providing & fixing glass urinal partition of Height: 900mm,Width: 450mm &Frosted Safety Glass: 8 mm with fixed with expandable anchor fasteners with C.P. brass bolts and washers, embedded in wall with anchor and set in cement concrete complete including cutting and making good the walls wherever required (Make: Jaguar Model No. 1810-US/1810-UC or equivalent) |
| 94 | Supply and install thin rim Wash basin vanity in white color for over counter mounting (Size:463mm x 325x 135mm), specially fabricated brackets, painted white, 32mm dia CP waste coupling and 12 \\" bottle trap with nipple, nut, ring and rubber washer etc complete. with C.P. wall flange and rubber adopter for waste connection, complete including cutting and making good the walls, wherever required. (Make: Jaguar Cat No. Solo SLS-WHT-6901, Essel Cat No. 72031300, or equivalent) |
| 95 | Supply and install CP brass single lever hi flow wash basin mixer with wall mounted exposed part and concealed installation- Diverter (35mm) complete including cutting and making good the walls where required. (Make: Jaguar Cat No. OPP-15233NKPM, Essel Cat No. 132301(Exposed Part) ,180208(Concealed Part) , or equivalent) |
| 96 | Fixing testing and commissioning of white vitreous china adjustable type wash basin with elbow oprated tap for handicap toilet (size as per architect/client), specially fabricated C.I./M.S. brackets, painted with two or three coats of enamel paint of approved shade over a coat of primer, 32 mm C.P. brass waste and C.P.brass cast brass bottle trap and pipe to wall with C.P. brass flange and rubber adopter for waste connection complete including filling gap between counter and wash basin with approved type poly sulphide sealant, 32 mm dia seamless stainless steel tube coated with nylon non-slip gripping surface 600 mm long grab bar complete with all accessories. Including cutting & making good the walls & floors wherever required. |
| 97 | Supply and install Stainless Steel kitchen sink (Size: 24\\"' x 18\\" x 9\\") (SS 304)without drain board as per manufacturers specification and direction of Engineer with CI brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. (Make: Essel Cat No. 534124, or equivalent) |
| 98 | Supply and install CP brass Sink mixer - wall mounted with full motion 355mm extended spout and aerator complete including cutting and making good the walls where required.(Make: Jaguar Cat No. LYR-CHR-38165, Essel Cat No. 131269, or equivalent) |
| 99 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115 mm nominal bore |
| 100 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 101 | Providing and fixing toilet paper holder :C.P. brass |
| 102 | Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colours weighing not less than 105 gms |
| 103 | Providing and fixing ABS/Plastic body paper towel dispenser complete with brackets fixed to wall with PVC rawl plug with CP brass screws complete in all respects, including cutting and making good the wall wherever required. |
| 104 | SOIL, WASTE & VENT PIPING:Providing and fixing soundproof Multilayer Polyproplene piping system as per EN 1451-Part 1-6 with 3 layer pipe made of PP + PP-MD + PP in white color and three layer fittings in PP MD, push-fit type,Halogen and Calcium free, having high impact resistance as per DIN EN ISO 291:2008-08 , Ring stiffness SN6 6KN/m2 as per ISO 9969, offering sound levels of not more than 17 dBA as per EN 14366 at a flow rate of 4 l/s, water tightness as per EN 1451-1 minimum of 0.5 bar for 15 minutes, density of pipe = 1.15gms/cm3, elongation = 0.09mm/m0K and E modulus 2300-3000 as per ISO 178, along with factory fitted EPDM lip ring. (Including pipe, fittings and supports complete in all respect.)40 mm OD (class 3 (6 kg/cm2) |
| 105 | 50 mm OD (class 3 (6 kg/cm2) |
| 106 | 63 mm OD (class 3 (6 kg/cm2) |
| 107 | 100 mm Dia |
| 108 | Providing and fixing Polyproplelene (PP) P-Trap including setting with cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 hand stone ballast 20 MM nominal size) the inlet from floor level to trap rim to be grouted and cemented neat manner including cutting and making good the floor & wall wherever requiredcomplete in all respects.100 x 100 mm outlet |
| 109 | Providing & fixing (PP) inlet fitting with one or more inlets fabricated from 110 mm outer dia (PP) pipe and solvent welded sockets and fixed to (PP) Trap and set in cement concrete as per drawing complete |
| 110 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources |
| 111 | Providing, fixing and testing of reducing floor drain of 110x63 mm OD as floor drain in cement concrete 1 : 2 : 4 float with floor complete in all respects as directed by Engineer-incharge complete as per standard design. |
| 112 | Providing and fixing 125 mm dia, 1 mm thick CP grating with frame for floor traps or drains of required pattern including cutting and making good the floors complete in all respects as directed by Engineer-incharge complete as per standard design.125 mm dia |
| 113 | Providing and fixing in position 125x125 mm square / 125 mm dia stainless steel cockroch trap consisting of 0.45 mm thick inner and outer cup and 1.0 mm thick top grating (Jali) with ring to be fixed inside uPVC ‘P’ traps with cement concrete. (for kitchen and pantry) |
| 114 | RAIN WATER PIPES:Providing, fixing, jointing and testing of uPVC pipes conforming to IS 4985 class III (6 kg/cm2) including injection moulded fittings with bosses like tees, bends, access door bends, single/double 'Y' , crosses, reducers, end caps, cowl etc. with or without access doors jointed with approved solvent cement as per manufacturer's recommendations, including under floor or fixed to walls and ceilings with Hilti powder coated pipe support channel, clamp with EPDM rubber, rod/hardness, fastner, nuts, bolts etc. as per manufacturer's recommendations complete including cutting and making good the floors and walls where required complete in all respects as directed by Engineer-incharge complete as per standard design. 110 mm |
| 115 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams. |
| 116 | INTERNAL WATER SUPPLY:Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes SDR 7.4 U V stabilized & anti -microbial fusion welded, having thermal stability for hot & cold water supply including all PP - R plain & brass threaded polypropylene random fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer in Charge. (Internal work exposed on wallPN - 16 Pipe, 25mm OD (SDR-7.4) |
| 117 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes SDR 7.4 U V stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Chajge. (Concealed work including cutting chases and making good the walls etc.)PN-16 Pipe, 20 mm OD (SDR-7.4) |
| 118 | PN-16 Pipe, 25 mm OD (SDR-7.4) |
| 119 | PN-16 Pipe, 32 mm OD (SDR-7.4) |
| 120 | PN-10 Pipe, 50 mm OD |
| 121 | Providing & fixing of material for the insulation of pipe with nitrile tube, tapping with cello tape, rockwool 6 inch per side wire mesh , polyethlene tapping with cello tape aluminium sheet 26 gauge cladding with dia complete job including carriage19mm thick 50mm dia (OD) PPR 20mm |
| 122 | 19mm thick 50mm dia (OD) PPR 32mm |
| 123 | Providing & fixing of material for the insulation of pipe with nitrile tube, tapping with cello tape for inner wall fittings, complete job including carriage, 19mm thick 50mm dia (OD) PPR 25mm |
| 124 | Providing & fixing heat tape 33 watt on PPR pipes made of denforced or chromelox or equivalent make , as approved by engineer in charge , complete job |
| 125 | Providing and fixing ball valve (brass) of approved quality complete : High or low pressure with plastic floats:20 mm nominal bore |
| 126 | 25 mm nominal bore |
| 127 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :50 mm dia |
| 128 | Providing and fixing motorised valve (with by pass line including ball valve) with float type sensors suitable for 240 volts with working pressure rating of not less than 5 kg/cm2 with control panel and sensors to open valve when water level is low in tanks and to close when water level is high in water tanks including necessary cables, conduits, upto junction box, pipe, butter fly/ball valves, flanges, union, nutbolt etc., complete in all respects as directed by Engineer-incharge complete as per standard design.32 mm dia |
| 129 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources. |
| 130 | Providing and Fixing of material for the insulation of water storage tank of with nitrile sheet, tapping with cello tape, rockwood 6 inch per side, wire mesh, polythene, aluminum sheet 26 gauge cladding with dia of, complete job. 19 mm thick nitrile sheet. |
| 131 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI :12701 marked with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank |
| 132 | EXTERNAL SERVICES:EXTERNAL SEWERAGE SYSTEM:Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kind of soil Pipes cables etc exceeding 80 mm dia but not exceeding 300 mm dia. |
| 133 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :200 mm diameter |
| 134 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 135 | Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :With Solid Block |
| 136 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as perstandard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.Extra for depth for manholesSize 90x80 cmWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 137 | Extra for depthfor manholesSize 120x90cmwith common burnt clay F.P.S (non modular) bricks of class desihnation 7.5 |
| 138 | EXTERNAL STORM WATER DRAINAGE:Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kind of soil Pipes cables etc exceeding 80 mm dia but not exceeding 300 mm dia. |
| 139 | Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.200 mm dia. |
| 140 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 141 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 455x610 mm and 45 cm deep for single pipe line :With Solid Block |
| 142 | Extra for depth beyond 45 cm of brick masonry chamber :For 455x610 mm sizeWith Solid Block |
| 143 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as perstandard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
| 144 | EXTERNAL WATER SYPPLY:Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kind of soilPipes cables etc exceeding 80 mm dia but not exceeding 300 mm dia. |
| 145 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes SDR 7.4 U V stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings i/c trenching .refilling & testing of joints complete as per direction of Engineer in Charge. (External work)PN-16 Pipe, 25 mm OD (SDR-7.4) |
| 146 | Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size ) necessary excavation7foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :With Solid Block |
| 147 | P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls and floors:80mm dia nominal bore |
| 148 | PUMPS & SOLAR WATER HEATING:Supplying, installing, testing, and commissioning of a 2000 LPD solar water heating system with a heat exchanger type, including electrical heater backup, 1000 Ltrs. make-up water tank, recirculation pump, and electrical Panel. (As per the Approved Technical Data sheet). |
| 149 | INTERNAL ELECTRICAL WORKS:SUB-A POINT WIRING , DISTRIBUTION BOARD & SOCKETS:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A |
| 150 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as requiredGroup A |
| 151 | wiring of following light point with 1.5 sq.mm FRLS PVC insulated copper conductor cable in PVC conduit recessed including chasing of wall, filling of chases with cement mortar 1:3 mix and /or fixing conduit on surface of wall/ceiling including fixing of saddles etc. including modular range of plate switches, modular cover plate, ceiling rose, surface or deep tee, circuit wiring (2x2.5+1x2.5), 1.5 sq.mm FRLS PVC insulated copper earth wire, etc. complete as required. One point controlled by one number 10 Amp MCB (First point) |
| 152 | Looping Point above |
| 153 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 154 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 155 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 156 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 157 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 158 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 159 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 160 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 161 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 162 | Supply & fixing of Universal Socket with 4.0 sq.mm PVC insulated multistranded copper conductor cable (FRLS Type) in surface / recess 1.8 mm thick PVC conduit including cutting the chases in wall & making good the same including providing & fixing of M.S. Switch & outlet box, modular range 13Amp switch with 3 pin 13Amp socket, modular cover plate, earthing with 4.0sq.mm PVC insulated copper conductor cable / wire (FRLS Type) etc. complete as required & as per specifications. |
| 163 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)6 way (4 + 12), Double door |
| 164 | 8 way (4 + 18), Double door |
| 165 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door |
| 166 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 167 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 168 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 169 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 170 | MAIN PANEL:Incoming:1 no. of 160 Amp FP MCCB of 25KA breaking capacity.Metering for incoming:Digital Multifunction meter with RS-485 communication port for measurement of PF, V, A & Hz , equivalent to EM6459,with CT as required.Phase indicating lamps RYB with 2 Amps SP MCB back up.ON / OFF indicating lamps Bus Bars:Electrolytic high conductivity aluminium three phase and neutral busbars rated at 200 Amps, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. Current density of Bus Bar to be 1.3 sq.mm / amp.Outgoings\\"10 no. of 63 Amp 4P MCB of 16KA breaking capacity.5 no. of 40 Amp DP MCB of 16KA breaking capacity.GROUND FLOOR PANEL-1 as described above . |
| 171 | SUB-B LIGHTS & FANS:SITC OF 9 W LED 6500 K Slim, compact, auminum die cast edge lit panel. Recess mounted round fixture with opal diffuser and separate electronic driver. MAKE :- Havells |
| 172 | Supply installation testing commissioning of TRIM CLIPON LED PANEL SQUARE 24 W LED 6500 K Make:- Havells Model:-LHEAABP7IN1W024 |
| 173 | SITC of 10 W WH LED Bulkhead Light as/Specification,PDC AL Housing,system watage -10 w,Lumen pack - 800 with eficacy - 800lm/w,CRI-80. , IP -65,Surge protection - up to 5 kv with IS 10322 (part 5/Sec.1)-2012. |
| 174 | SITC of 5W Led Mirror Light |
| 175 | Supply installation testing commissioning of 1400 mm fan |
| 176 | SITC of Track Light (Decorative Item to be confirmed by interior) |
| 177 | SITC OF 12 W LED LIGHT (Decorative Item to be confirmed by interior) |
| 178 | SUB-C ELV SYSTEM (LAN ,CCTV & EPABX)Supply, installation, testing and commissioning of 24-Port Gigabit Smart Managed Switch having 48 x 10/100/1000BASE-T ports, 4 x Combo 10/100/1000BASE-T/SFP ports , 104 Gbps Gbps Switch Capacity, 77.4 Mpps Max. Packet Forwarding Rate , 992,594 hours MTBF, etc complete as required.(Make:- D-LINK/CISCO/HP) |
| 179 | Supply, installation, testing and commissioning of 24 Port cat-6 Patch panel available with Identification: ID plate, PVC, Transparent color with paper,Six Port RJ45 modules applied ,Compatible with both 110& Krone punch down tools, Improved Cable Management with optional cable management bar, Insertion force: 20N max.etc as required.(AMP/D-LINK/MOLEX) |
| 180 | Supply, installation, testing and commissioning of 1meter cat-6 patch cord for connecting socket module/modular wall face plate outlet and work stations in the premises etc complete as required..(AMP/D-LINK/MOLEX) |
| 181 | Supply, installation, testing and commissioning of 4 U Floor mounting rack with Front Door with Toughened Glass quality. Adjustable Mounting rails - Front and Back, Fan Mounting provision, bottom cable entry provides Optimal flexibility for cable management, power poins, Frame structure with max loading capacity, etc complete as required.(NETRACK / VALRACK / D-LINK) |
| 182 | Supply, Installation, Testing & Commissioning of Network WDR 2MP IR Rugged Mini Dome Camera having 12.8” 2 Megapixel progressive CMOS image sensor, Min. Illumination required 0.002ux/F1.5(color,30IRE) 0Lux/F1.5(IR on), 120dB True WDR, H.265/H.264B/Smart Codec / MJPEG (Sub Stream), 2.7mm~13.5mm, Motorized, F1.5 lens, Smart IR with upto 40m IR distance, Up to 128 GB microSDHC card, Class 10 (not included), DC12V, PoE (802.3af) (Class 0), ingress protection IP67, vandal resistance IK10, ONVIF Profile S/G/Q, FCC Part 15B, EN 55032,EN 50130-4,UL 60950-1, EN 62368-1,EN 50581,etc as required. (HONEYWELL/BOSCH/AXIS) |
| 183 | Supply, Installation, Testing & Commissioning of Network WDR 2MP IR Bullet Camera having 1/2.8” 2 Megapixel progressive CMOS,2.7 mm – 13.5 mm MFZ Lens,True day/night (IR-cut filter),Wide dynamic range up to 120 dB,Low-light performance down to 0.002 Lux / F1.5 (color, 30IRE), 0 Lux (IR ON),Up to 197 ft (60 m) IR lumination, H.264/H.264B/H.265/Smart Codec/MJPEG (Sub Stream) , Support up to Up to 128 GB micro SDHC card, Class 10 (not included), DC12V or PoE (802.3af)(Class 0), IP67 INGRESS PROTECTION ,ONVIF Profile S/G/Q, FCC Part 15B, EN 55032, EN 50130-4, UL 60950-1, ROHS- EN 62368-1, certifications, etc as required.(HONEYWELL/BOSCH/AXIS) |
| 184 | Supply Installation Testing and Commissioning of 8 Channel DVR (Digital Vedio Recorder) having Quad-core embedded processor , Embedded LINUX ,1 HDMI (up to 3840 × 2160);1 VGA , H.265/H.264/MJPEG/MPEG4 compression, 2 SATA ports, up to 16 TB, Input 320 Mbps; Output 320 Mbps network throughput , 8 ports (802.3af/at) POE, FCC , ROHS , UL Certifications,etc as required. (HONEYWELL/BOSCH/AXIS) |
| 185 | Supply, installation, testing and commissioning of 4TB Surveillance Hard Disk S V SERIES-offer high capacities, durable reliability and performance tuned to the high-write workloads of today’s 24×7 video surveillance systems as required. ( SEAGATE/WD/HITACHI) |
| 186 | Suppling,Laying & fixing of 15 MTR HDMI cable on surface as reqd .(Stackfine/Extron/Kramer) |
| 187 | Supply, installation, testing and commissioning of 1 KVA UPS with 30 minutes back-up with inbuilt battery complete etc as required. (APC/MICTOTEK/VGUARD) |
| 188 | Supplying and commissioning of 9 U rack with 1 no extra tray , Power Distribution Unit of 05Amps of 05 nos.Socket in a Single Pole / Screw,Mountable,etc as required.(WQ/VALRACK/D LINK) |
| 189 | Supply, installation, testing and commissioning of 10 Port Managed POE Switch having 8 nos 10/100/1000 PoE ports with 62W power budget and 2 Combo mini-GBIC ports , Static routing, QoS, Voice/Guest VLAN, GVRP, MSTP, IGMP Snooping, Time-based Access Control Lists , 802.1x including DVA, Web-based Authentication, IP/MAC Binding, Private VLAN Edge, IPv6 First Hop Security, IP Source Guard as requird.(Make – CISCO – Model - SG – 350/ 10 /HP/JUNIPER) |
| 190 | Supply, installation, testing and commissioning of 32\\" LED monitor includes Screen size :32\\" Diagonal Size, LED BLU type technology, resolution- 3840 X 2160 ,250 nits brightness, 4700:1 contrast ratio, stereo mini jack, HDMI I/p-2 , USB-1, compatability for wifi, bluetooth suitable for operation on AC Power supply AC 240 V~ (+/- 10 %), 50/60 Hz,etc required.(SAMSUNG, Model – BE 43TH/SONY/LG) |
| 191 | Supply Installation, Testing and Commissioning of TEC approved as IP Enabled PBX- Voice Server expandable upto 100 extensions & configured, Personal Assistant, UCaaS Hybrid Cloud Solution for Business Collaboration and Communications, Pimphony Basic 100 license CTI Integration, Voice mail 1 Hr/2ports default, Distribution list and online recording feature license, 6 party meet me conference license, Automatic Route Selection (ARS), Hot desking 2 user license, 16 inbuilt Voice compression DSP resource, IP ready from day1, SIP Openess, Inbuilt PMS/HMS Link. Presently Configuration as Below . CO Line 1Nos. PRI 1Nos. Digital Extensionss 1Nos Analogue Extensions 10Nos. Make: Avaya, Alcatel, Unify, Cisco |
| 192 | Supply Installation, Testing and Commissioning of Operator Phone : INT Premium Deskphone Moon Grey, 4 grey level display, white backlight, Handsfree, Comfort handset, Magnetic alphabetic keyboard, Jack 3,5 mm 4 pole. Make: Avaya, Alcatel, Unify, Cisco |
| 193 | Supply Installation Testing and Commissioning of Analogue phone with CLI & speaker. Make: Avaya, Alcatel, Beetel . |
| 194 | Supplying & Fixing of Non- PCB based Information Outlet (I/O) RJ45, Termination TIA-568C Category-6, Termination of Catergory-6 UTP Cable, UL listed ,Shall conform to Category-6 as per the EIA/TIA-568C.2,Shall support network line speeds up to 1 Gbps, Shall have RJ-45 type connector with bend limiting and strain relief boot for securing IDC contacts from external forces and for maintaining the bend radius of the cable, Shall have minimum duraility of 950 or Above mating cycles and 200 termination cycles. Certified by independent labs like ETL/GHMT/3P for compliance to EIA/TIA-568C.2 complete in all respect.( For Data, EPBAX and CCTV) . Make- Legrand, Molex, Panduit. |
| 195 | Supplying & Fixing of Single Faceplate dimension as per commercially available modular office furniture.Shall have spring shuttered front access for preventing ingress of dust,Shall be supplied with Gang Box of the same size by System Integrator complete in all respect. .Make- Legrand, Molex, Panduit. |
| 196 | Supplying & Fixing of Floor Standing Network Rack - 15U /600d, with Heavy Duty Extruded. PDU 5/15Amps with MCB, Mounting Hardware (Pkt. Of 3) Cable manager 3Nos -1U with Loops complete in all respect. Make- Rittal, Valrack, APC. |
| 197 | Supply Laying Testing and Commissioning of 2 Pair Solid Annealed Bare Copper, Armoured Jelly Filled Cables, Nominal Diameter of each strand No./mm 1/0.5, Solid polythene confirming to ASTMD-1248 Type-II or III, Class-A Cat. 4 or 5 (cl.4.0 of TEC GR/CUG-01/03 Aug.03), Screening- Material Polyal Tape ( as per Cl.No. 9.0), Thickness mm 0.3 +/- 15%,. Make- Delton, Finolex, Polycab. |
| 198 | Supplying of 4-pair Unshielded twisted pair with a cross filler (+), meeting Category 6 standards as per TIA-568C.2, The cable should be tested till 250 MHz , Shall be Fire-Retardant, Low-Smoke & Zero-Halogen as per IEC 60332-1, IEC 61034-2 & IEC 60754-1 respectively.. conisidered for DATA, CCTV+ Voice) Make- Legrand, Molex, Panduit. |
| 199 | Supply, Laying, testing and commissioning of 10 lines Floors MDF Box complete as required. |
| 200 | SUB-D (FIRE ALARM & DETECTION):Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS systemwith open protocol BACnet/ Modbus over IP complete as per specificationsTwo Loop Panel |
| 201 | Supplying, installation, testing & commissioning of fault isolator complete with base as required |
| 202 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. (If the device does not have inbuilt isolator module then the bidder has to provide isolator module after every 15 devices within the cost of the detector and for this nothing extra shall be paid.) |
| 203 | Supplying, installation, testing & commissioning of addressable manual call point complete as requiredApproved by EN54/VDS/LPCB/UL. |
| 204 | SITC of contact dual input module used for monitoring contacts and signals to the Fire Controller, status of monitored contacts and wiring to the contacts can monitor a single normally closed contact. Approved by EN54/VDS/LPCB/UL. |
| 205 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required |
| 206 | Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. |
| 207 | Supplying & laying of 2 x 1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. |
| 208 | Supplying, installation, testing & commissioning of addressable fire control module complete as required. |
| 209 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25mm |
| 210 | SITC of Digital 250 W (mini.) Class D, high efficiency amplifier shall be an EN54-16 compliant and certified system device in a 2 RU, 19”cabinet. The amplifier shall be permanently monitored by the system controller.A special standby mode shall be provided for saving energy during the time the amplifier is not is use with respect to all economical and supervision aspects.• 480 Watt Class D amplifier• 4 channel input on RJ45 connector, amp link in and out(4 channel dynamic input channel switching for each amplifier• Amplifier efficiency >= 78%• Limiter prevents audible distortionSignal to noise ratio, A-weighted: >104 dB |
| 211 | Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. |
| 212 | Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc.complete as required |
| 213 | Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. |
| 214 | HVAC ITEMS:SUB-HEAD :-1 INDOOR UNIT-4-WAY CASSETTE TYPE:Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor)BASEMENT FLOOR Cassette unit : 1.28 TR |
| 215 | CASSETTE PANELS:Supply, Installation, Testing and Commissioning of decorative panels for cassette type indoor units. |
| 216 | SUB-HEAD:- 2 PIPING WITH INSULATION:COPPER REFRIGERANT PIPING:Supply, installation, testing and comissioning of interconnecting copper refrigerant piping of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified 'Class O' in Fire Propagation as per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work.Pipe Size Thickness of CSE(O.D.) Insulation19.1 mm O.D., wall thinkness ≥ 1.0mm (insulation – 13 mm thick) |
| 217 | 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) |
| 218 | 9.5 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) |
| 219 | 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) |
| 220 | CONDENSATE DRAIN PIPING -cPVCProviding & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work. 25mm dia |
| 221 | SUB-HEAD:- 3 MECHANICAL VENTILATION WORK:INLINE FAN:Supply , installation , testing and commissoning , of duct mounted circular / rectangular inline fans complete with direct driven centrifugal fan , TEFC squirrel cage induction motor , with efficiency class IE-3 , direct drive arrangement , heavy gauge sheet metal casing , rubber isolator mounts and other accessories.The fan shall be complete in all respect and should match the specification ,Drawings and Schedule. Inline fans shall be of following capacities.750 CFM Total static pressure of 10 mm WG |
| 222 | SUB HEAD:- 4 DUCTING & GRILLESGSS DUCT (FACTORY FABRICATED)Supply, fabrication, installation, testing and commissioning of GSS sheet metal ducting for supply & return air with all the accessories and hanging arrangement. It shall include bends,elbow,tees, spliter,fittings,gaskets and all accessories for complete installation of ducting . Refer tender specification for detail description:24 G (0.60 mm) |
| 223 | LINEAR BAR GRILLSupply, installation, testing,balancing and fixing of Powder coated aluminium extruded grill with aluminium construction collar damper for supply / Return air 150 mm wide as per specification & the sizes will be as per schedules and drawing.Refer technical specification for detail description. |
| 224 | EXHAUST AIR GRILL:Supplying, Installing, testing and commissioning of powder coated extruded aluminium exhaust air grille with min.60 % free area, with metallic frame work & fixing accessories, to be fixed on external wall to exhaust air from basement area to ambient , it shall be suitable for exhausting required air in CFM . Louvers need to be suitable in order avoid rain water entry in to basement @ 15 degree deflection with bird screen complete as per specification approved drawings and schedules. |
| 225 | Supplying, installing, testing and commissioning of GI construction fresh/exhaust air louvers with min. 60 % free area, bird screen and painted in baked enamel shade as per clients or architect approval with metallic frame work complete as per specification approved drawings and schedules. |
| 226 | SUB HEAD:- 5 SPLIT AIR CONDITIONING SYSTEM'HI-WALL TYPE SPLIT UNIT:Supply, Installation ,testing & commissioning of Hi Wall split air-conditioning unit of below mentioned capacity suitable to operate from 230+10% volt, 50 Hz, 1/3 phase power supply, with air-cooled evaporator with coil, fan, and fan motor, air-cooled condenser with thermetically sealed scroll/rotary type compressor condenser coil, propeller fans controls, control panel, drain pan. The charging of ref/oil if required shall be included in the cost, including Remote Thermostat,Stablizer,outdoor unit stand & with all accessories. Including control wiring, necessary power cable, drain piping & pair of copper piping upto 18m length. The Unit should be 3 Star rated (on the date of procurements the minimum EER value of the units should be as per BEE Standard ).1.5 TR (5.2 KW) |
| 227 | Fire Fighting Items:SUB HEAD-A (PIPING & VALVES):Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges ,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 25 mm dia. |
| 228 | 100mm dia |
| 229 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required :100 mm dia |
| 230 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore. |
| 231 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :150 mm dia. |
| 232 | 100 mm dia. |
| 233 | Providing and fixing dial type pressure gauge with isolation cock and copper pipe at hydrant station.Dial diameter 100 mm calibration 0-15 kg/ sq.cm. |
| 234 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100mm dia |
| 235 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. |
| 236 | SUB HEAD-B (FIRE HYDRANT ACCESSORIES):Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Gunmetal |
| 237 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve &nozzle. Drum and brackets for fixing the equipmets on wall.Connections from riser with 25 mm dia stop gun metalvalve & M.S. Pipe and socket.30m |
| 238 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Gun Metal |
| 239 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling asrequired :Gun Metal |
| 240 | Providing and fixing door with frame for all internal fire hydrants fabricated from 20x20x3 mm and 40x20x3 mm aluminium hollow box sections mounted with 3 no. of 100 mm Aluminium butt hinge on Aluminium angle frame of 45x45x5 mm size with hold fasts fixed to wall with P.C.C. (1:2:4) blocks 100x100x100 mm including 2 nos allen key lock for locking along with padlock arrangement & fully glazed with 4 mm thick float glass approved by local Fire Authority, powder coated fire red finish with \\" fire hose' written on front suitable to house 15 mm long two length of canvas hose with couplings, one no of branch pipe, one fire mans axe and two numbers of portable extinguishers, first aid fire hose and supports for hoses, branch pipes, Axe and hose reel. Size 1200x 600 mm complete as per approved design including necessary fixing arrangement for hoses & axe and branch pipe.) |
| 241 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904as required :2 way-100 mm dia M.S. Pipe |
| 242 | 3 way - 150 mm dia M.S. Pipe |
| 243 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. |
| 244 | SUB HEAD-C (FIRE EXTINGUISHERS & MISC. ITEMS)Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylindrical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 15683 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge. Capacity 4.5 kg. ISI Marked.( Contractor should submit test certificate form manufacturer along with serial number of every extinguishers supplied.) |
| 245 | Providing and fixing water Co2(ISI marked) extinguishers including all accessories as per IS specification with wall bracket with rawl plugCapacity 9 liters.(IS:15683) |
| 246 | Providing and fixing of self illuminated / auto glow \\"EXIT\\" signs printed on photoluminescent sheet containing self illuminated base chemical, of appropriate size not less than 400 x 150 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site. |
| 247 | SUB HEAD-D (FIRE PUMPS & ACCESSORIES)Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads.450 lpm at 35 m Head |
| 248 | Providing and fixing liquid level controller for fire pump to stop fire pump in case of low level of water in tank , cost of conduit, cable and panel including making connection to pump panel and commissioning complete.Float type Sensor with panel and installation |
| 249 | Providing and fixing rubber expansion joint (to provide relief from stresses at pipe flanges) as per specification of the manufacturers and direction of Engineer in chief PN-16 rating100 mm dia |
| 250 | Supply ,install, testing and commissioning of 3 Phase 25kw On Grid Solar Power Plant Solar module (545-550Wp) Mono PERC, with the following specifications: 1)System Capacity : [3Phase ongrid 25kw]2)Type of System: [ongrid solar]3)Module Wattage: [ 545-550 Wp]4) Inverter Model:[Ongrid 25kw, 3 Phase]5) Mounting Structure: [Hot-Dip Galvanized]6) Warranty: [25 years on solar modules, 2 years on inverter]7) Module mounting structure = 1 set (as per requirement).8) Array Junction Box = 1 no (as per requirement).9) DCDB = 1 no.10) 3 phase, 25kW, (200-850V) MPPT, PCU(inverter) On Grid based =1no.11) 1C x 4 sqmm DC copper cable = 30 mtr ).12) 3.5C x 20 sqmm AL unarmoured AC cable =20 mtr13) MC4 connectors = (as per requirement).14) ACDB = 1 no.15) Earthing = 10no.16) Installation Kit (cable tie, Thimble, Ferrules, aluminium earthing strips, Earthinginsulators, saddles, PVC conduit and bands, etc.)17) Installation included Make: Luminous, Tata Power Solar,Adani Solar or equivalent. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail