| 1 | Supplying, fittingand fixingboilingwater resistant plyconforming toIS:303 1989bondedwithphenol formaldehyde synthetic resinof approvedmakeand brandfittedandfixedasperdesignasperapprovalanddirectionofEngineer-in Charge.[excluding the cost of supporting frame work and teak woodbatten/Lipping] In Ground Floor (vi) 19mm |
| 2 | Supplyingfitting, fixingdecorativelaminationconformingtoIS:2046:1995as perapprovedmake, brand, finishand thicknesswith fitting, fixing thesameon Particle/MDF/PlyBoardswithrecommended/approvedadhesivewithproper clipping the sides for better attachment as per direction of Engineer-in charge.Therateincludes thecostof labour,adhesiveandall incidentalcharges thereof. In ground floo (ii) Thickness of laminate 1 mm |
| 3 | (C) Supplying Heavy Duty Aluminium Handle (EBCO Type) (Natural White) |
| 4 | Iron pad bolt (lock) of approved quality rod and handle single cast: (i) 115mm x 10mm dia rod 65mm x 3mm plate. |
| 5 | Supplying solid flush type doors of commercial quality, the timber frame consistingof topandbottomrailsandsidestylesofwellseasonedtimber65mm wide each and theentire frame fitted with37.5mm wide batten splaces both ways inorder tomake thedoor of solidcore and internal lippingwithGarjanor similarwoodveneersusingphenol formaldehydeasglueetc.complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. (b) 32 mm thick shutters (single leaf) |
| 6 | i)HydraulicdoorcloserofapprovedqualityasperI.S.I.standardfittedandfixed complete. (c) Light type |
| 7 | i) Ironhaspbolt of approvedquality fittedand fixedcomplete (oxidised)with 16mm dia rod with centre bolt and round fitting. |
| 8 | Supplying best Indian sheet glass panes set in putty (as per I.S specification) and fitted and fixedwith teakwoodbeads andnails complete. (Inall floorsforinternalwall&upto6mheight forexternal wall) (ii) 4 mm thick |
| 9 | Woodwork in door andwindow frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete,Iron Butt Hinge sand M.Sclamps.(Thequantumshould be correted upto three decimals). (f) Sishu, Gamar, Champ, Badam, Bhola, Mogra, Hallak |
| 10 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. (I) For structural members of specified sections weighing less than 22.5 Kg./m |
| 11 | Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) (Asian Paints, Birla, J.K. or Eqv.)SOR, PWD, P- 198, I - 5In First Floor |
| 12 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsionpaint includingscrapingandpreparingthesurfacethroughly, completeaspermanufacturer'sspecificationandasperdirectionofthe EIC. (a) One Coatfoundation, |
| 13 | (A)Painting with best quality synthetic enamel paint of approved make and brand including smooth ening surface by sand paperingetc. Including using of approved putty etc. on the surface, if necessary :(iv) Two coats (with any shade except white) |
| 14 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (ii) With 1:4 cement mortar (a) 15 mm thick plaster |
| 15 | (b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 16 | Supplying, fitting & fixing of partly glazed partly panelled or fully glazed single leaf Aluminium swing door of all aluminium sections viz door frame ( top and side frame), shutter( top rail, bottom rail, lock rail, door vertical) , glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868 1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium door with door spring,/aluminium hinges, glass / Panel board all complete as per architectural drawings and direction of Engineer-in charge. ( Excluding cost of glass/ panel board, door spring/ Al hinges, door closer, door stoper, handle, tower bolt and locking arrangment etc) 10-12 Micron thickness Annodizing film Natural white(unit wt of to Top & side frame @1.366 kg/m ; top rail @ 1.296 kg/m; bottom rail @ 1.974 kg/m; lock rail @ 1.590 kg/m; door vertical @ 1.412 kg/m; glazing clip @ 0.167 kg/m. ) [Note : for estimate purpose construction wing may consider weight of Aluminium door @ 9.0 Kg per Sq.M] |
| 17 | Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987; (A) clear, toughened glass conforming to IS: 2553-1992 (part-II) (i) 6mm thick |
| 18 | Providing and fixing exterior quality Aluminium Composite Panel(ACP) wall cladding on existing Al./MS frame work with GI brackets ,ACPfixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CPa ngles,cleat sand strainless Steel screws form inggrovesat the periphery of ACP panel. Such grooves filled with foamand silicon sealant etc. complete with all materials (but including thecost of siliconsealant), labour, scaffoldingandall other incidental charges complete in all respect as per specification and directionofEngineer-in-charge. (Modeofpayment isonfinishedsurface area of ACP) a) 3mm thick (0.25mm Al.+2.5mm LDPE +0.25mm Al. PVDF coating) |
| 19 | Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge.10-12 Micron thickness Annodizing filmNatural white[Note : for estimate purpose construction wing may consider weight of 2-track Aluminium window @ 5.5 Kg per Sq.M.and 3-track Aluminium window @ 6.5 Kg per Sq.M] |
| 20 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidentalchages such as electricity charges, labour insurance charges etc.Payment to be made on the basis of calculated weight of structuralmembers only in finished work as per IS specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finished structural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished structal members weighing less than 22.5 Kg. / m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc. and no seperate payment being made for these items, as per direction of Engineer In Charge. The rates are considered for a height of erection 8m. / 2nd floor level from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initiial 8m. or part thereof.I) For structural members of specified sections weighing less than22.5 Kg./m @ 22.00KG/SQ.M |
| 21 | Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials., |
| 22 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work PVC Pipes, 25 mm |
| 23 | ADD 18 % GST |
| 24 | ADD 1% CESS Please Enable Macros to View BoQ information |