| 1 | Rebaring - Chemical-Supply and application of Lokfix E77, a heavy duty, two-component epoxy anchoring chemical, provided in 3:1 ratio side-by-side cartridges with a static mixer nozzle. Upon application, it sets and cures to securely anchor various steel fixings into concrete and solid masonry substrates. It is a pure epoxy chemical anchor grout with ETA approval from DIBt for diameters ranging from 8 mm to 40 mm at specified embedment depths, as per manufacturer's specifications. The epoxy chemical must have a working life period certified for 100 years as per ETA from DIBt, with properties including fire resistance tested to withstand 120 minutes (DIN EN 1363-1:2012, Technical Report TR 020), and must have water tightness certificate for \\"0\\" mm under 5 bar water pressure (EN 12390-8:2019). ETA approval from DIBt for Diamond Drilling is required, alongside LEED certification and compliance with LEED V4 standards (ISO 16000, EN 16516, CDPH 01350, ASTM D2369, EPA method 24). It should compilance with European approval to EAD 330499-01-0601, anchoring in cracked and un-cracked concrete, includes fire testing to 120 minutes and C1 & C2 seismic approval. It shuould have compressive strength >110MPa (EN196-1) and flexural strength >60MPa (EN196-1). Rates shall encompass labor, tools and plants for power drilling in concrete, epoxy cartridges, plastic nozzles, and complete drilling holes with dust removal by air blowing. Cost of providing, cutting, bending of rebar steel shall be paid separately as per approved item. |
| 2 | Rebar 8 mm Dia x 12 mm holes dia x 120 mm depth |
| 3 | Rebar 10 mm Dia x 14 mm holes dia x 150 mm depth |
| 4 | Rebar 12 mm Dia x 16 mm holes dia x 180 mm depth |
| 5 | Rebar 16 mm Dia x 20 mm holes dia x 240 mm depth |
| 6 | Earth Work |
| 7 | Earth Work in excavation in Foundation Trenches in Ordinary soil (vide classification of soil item -B) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I |
| 8 | CONCRETE WORK |
| 9 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded stone aggregate 20 mm nominal size |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand (zone-Ill) : 8 graded stone aggregate 20 mm nominal size (canopy) |
| 11 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. |
| 12 | Plant mix method (Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401) (ii) Rate per cum for grading-II Material |
| 13 | Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.) |
| 14 | Cement Concrete Pavement (Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing ) |
| 15 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. |
| 16 | 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern |
| 17 | Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 18 | Providing Retro-reflective regulatory sign board of size 900 mm dia meter made out of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated lens type retro -reflective sheeting as approved by Engineer-in-charge . Letter, symbols, borders etc. will be as per IRC - 67 with required colour scheme onthe boards and with the high intensity grade A. The aluminium sheet to be riveted to M.S. frame of angle iron of size 40x40x4 mm. The boards will be fixed to 1 No. 50x50 mm square post made of M.S. angle 50x50x4 mm, 4 m long welded to the frame with adequate anti-theft arrangement .Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat (primer) and back side of aluminium sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete in all respects as per direction of Engineer-in-charge. |
| 19 | REINFORCED CEMENT CONCRETE WORK |
| 20 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. |
| 21 | Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finished and reinforcement -all work up plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone -III) : 3 graded stone aggregate 20mm nominal size) |
| 22 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, cement content as per approved design mix, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. NOTE- (1) Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. |
| 23 | All works upto plinth level |
| 24 | Centering and shuttering including strutting, propping etc. and removal of form for: suspended floors,roofs,landings, balconies and access platform |
| 25 | Providing Tor steel reinforcement of 8mm. dia.TMT rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL)) |
| 26 | Providing Tor steel reinforcement of 10mm,28/32mm dia. TMT rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL)) |
| 27 | Providing Tor steel reinforcement of 12/16mm. & 20/25mm. dia. TMT rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL)) |
| 28 | BRICK WORK |
| 29 | Providing designation 75 A brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 30 | Providing designation 75A brickwork in CM (1:3) in superstructure with approved quality of clean coarse sand of FM 2 to 2,5 including providing 10mm thick mortar joints , cost of screening, materials, scaffolding, raking out joints to 15mm depth curing, taxes and royalty all complete as building specification and direction of E/I |
| 31 | Providing designation 100A brick work with flyash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:4) in super structure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints costs of screening materials, scaffolding, raking out joints to 15mm depth curing taxes and royalty all complete as per building specification and direction of E/I. |
| 32 | Providing designation 112mm thick reinforced designation 100A brick work with flyash lime brick (FLAG) in (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I. |
| 33 | Extra for providing & placing in position 2 no 6mm dia ms bar every 3rd corse of half brick masonary |
| 34 | Extra for brick work for each consecutive floor above first floor including watering and scaffolding, all complete as per direction of Ell. |
| 35 | WOOD WORK |
| 36 | Supplying, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows skylights, fanlights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all completeas per building specification and direction of E/I. |
| 37 | Supplying,fitting and fixing 38mm thick good quility well dressed and well seasoned sal wood fully paneled shutter in doors and window with 25mm thick panels with one side plain chamfered with oxidiesd iron fitting such as hinges, sliding door, bolts,tower bolts, handles or rings , hooks and eyes, cleats, sand blocks as per schedule, taxes and royalty all complete as per building specification and direction of E/I |
| 38 | Supplying, fitting and fixing 38mm , thick good quality well dressed and well seasoned Teak wood 1/3rd paneled and 2/3 glazed shutter in doors and window with 25mm thick panels with one side plain and other side chamfered with aluminium fittings such as hinges, sliding doors boltes tower bolts handles or rings, hooks and eyes, cleats, sand blocks as per schedule and 3mm thick plain glass panes fitted with teak wood beads and taxes all complete as per building specification and direction of E/I. |
| 39 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer- in-charge Profile C Fixing with adjustable lugs with split end tail to each jamb |
| 40 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 41 | For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 42 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 43 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer- in-charge Profile C Fixing with adjustable lugs with split end tail to each jamb |
| 44 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides. |
| 45 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid .in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 46 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge. (Cost of aluminium snap beading shall be paid in basic item) : With float glass panes of 5.50 mm thickness |
| 47 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With brass cover plate minimum 1.25 mm thickness |
| 48 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width |
| 49 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 50 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area of door shutter to be measured). |
| 51 | Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) : Rectangular or square. |
| 52 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S including cost of adhesive of approved quality 1.0 mm thick. |
| 53 | Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately). |
| 54 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.With 12 mm mild steel U beading |
| 55 | Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately). |
| 56 | Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete. |
| 57 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strengh congorming to is;4454-part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25mm M.S. laths with 1.25 mm thick top cover. |
| 58 | Providing and fixing ball bearing for rolling shutters. |
| 59 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 60 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: |
| 61 | 300x16 mm |
| 62 | 250x16 mm |
| 63 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete: |
| 64 | 250x10 mm |
| 65 | 150x10 mm |
| 66 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade wiIh necessary screws etc. complete : |
| 67 | 125 mm |
| 68 | 100 mm |
| 69 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete Twin rubber stopper |
| 70 | Providing and fixing bright finished brass 100 mm mortice latch and lock ISI marked with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete. |
| 71 | Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge complete 255 X 19 mm |
| 72 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 73 | Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete. Polyester Powder coated minimum thickness 50 micron aluminium. |
| 74 | Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. complete as per direction of Engineer-in-charge Polyester Powder coated minimum thickness 50 micron aluminium |
| 75 | STEEL WORK |
| 76 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 77 | Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.) |
| 78 | Supplying, fitting and fixing M.S. grill gate with M.S. grills made of 20x6mm M.S. flats or 16mm square bars fitted on 25x25x6mm M.S Angle frame including cost of fabrication , providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/l. |
| 79 | FLOORING WORK |
| 80 | Providing and laying 25mm thick. Kotah stone slab flooring of approved size, texture and colour over 19mm thick base of lime mortar (1:1:1) (lime putty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royality all complete as per building specification and direction of E/I.(iv) 600 x 600 mm size |
| 81 | Providing and laying 25mm thick kotah stone tiles in risers of steps skirting and pillars of approved size texure and colour laid over 12mm thick cement mortar (1;30 and joined with grey cement slurry mixed with pigment to match the shade of the slab including rub bing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 82 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 83 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry@ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 84 | providing and laying, vitrified step/dado tiles in with water absorption less than 0.08% and conforming to lS 15622/ of approved make in all cotours and shades, laid on 20mm thick cement mortar 1 4 (1 cement:4 coarse sand) jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of tile 1200x300 mm X15MM |
| 85 | providing and laying, Doublecharge vitrified floor tiles in different sizes (thickness to be specified by lhe manufacturer) with water absorption less than 0.08% and conforming to lS 15622/ISO 13009 of approved make in all cotours and shades, laid on 20mm thick cement mortar 1 4 (1 cement:4 coarse sand) jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of tile 600x600 mm |
| 86 | Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :Raj Nagar plain |
| 87 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills. facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, induding rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels .Granite of any colour and shade. Area of slab upto 0.50 sqm |
| 88 | Area of slab over 0.50 sqm. |
| 89 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc complete as per design approved by Engineer-in-Charge. Granite work. |
| 90 | Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. |
| 91 | Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete. |
| 92 | Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. |
| 93 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade |
| 94 | Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete. 8.mm thick Granite of any colour and shade |
| 95 | Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 metre. |
| 96 | WATERPROOFING WORK AND ROOF WORK |
| 97 | Providing & fixing Rockfone Stonewool Acotsical Ceiling PACIFIC High NRC (0.80), Fire Rating A1 (EN 13501-1), RH 100% (No visible deflection in high humidity), Superior Class Light Reflection, Sag Resistant 12mm thick Ceiling Tiles of size 600x600 A-Edge (Square) with AntiBacterial Properties & M1 Class Emission Certification made up with Natural Stone (Bassalt Rock) a complete Green Product & perfect suitable for any kind of False Ceiling application in builiding & costruction. The Visible side is a smooth white painted fleece, the Rear side: back fleece with complete facctory finish Painted edges. |
| 98 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. |
| 99 | The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all Tsections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. |
| 100 | With 16 mm thick beveled tegular mineral fibre Antimicrobial false ceiling tile confirming to ISO 5 (class 100 )specifications |
| 101 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 102 | 12.5 mm thick tapered edge gypsum moisture resistant board |
| 103 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of :v) Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. vi) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.vii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sqm of area. viii) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.) |
| 104 | Water proofrng for Old and New Roof Slab :- Providing and laying water prooflng treatment on roof slab by applying two Component, factory a designed ready to use, acrylic modified flexible material applied with brush, roller or spray waterproofi ng coating as per manufacturer specification-With following steps :- |
| 105 | (a)surface preparation :-Provrding and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika lndia Pvt.Ltd. |
| 106 | / MYK Schomberg / Dr Fixit/Fosroc or equrivallent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with '150mm X '150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent Before chamfering a prime coat shall be given with the slurry of acrylic polymer Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete. |
| 107 | (b)1st Coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application ,45 gsm oI Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/Sqmt/coat For the purpose of measurernent tte entire treated surface will be measured.\\" |
| 108 | (c) :2nd Coat:- To apply the 2nd coat of two component acrylic modified,ready to-use, flexible cementitious material right angle to the '1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 kg/ Sqmt/coat. For the purpose of measurement the entire treated surface will be measured.\\" Alter three days of drying the 2nd coal , the rain water outles to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification lo be done as per satisfation of E/c. |
| 109 | The Watqrproofing Brand:*Sil |
| 110 | 4624) Slant-Shear Bond Strength -4 N/mm2 (According to FIP 5.15) Elongation at Break -35% without Fibre Cloth and 20% wilh Fibre Cloth (According to ASTM D 2370) |
| 111 | D Protection of treated with pcc :- The treated surface shourd be covered with 25mm/50mm PCC of M-20 grade(1:1.5:3) with proper slope ( 1:120) towards the rain outlets in alternatepanels of 2 mtx2mt keeping 6 mm gap between the panel joint. integral water proofing admixture conforming to lS 2645 @ of 100 ml perbag of of cement to be added in the screed concrete (paid separately for thts ltems |
| 112 | all corners shall be charfered with 150mm X 150 mm fillet. The rain water outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of Sika lndia Pvt.Ltd / IVIYK Schomberg / Dr FixiUFosroc .For the purpose of measurement the entire treated surface will be measured.\\" |
| 113 | (e)Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand - Sika lndia Pvt Ltd / MYK Schomberg / Dr Fixit/Fosroc |
| 114 | Covering of treated surface wrth PCC :- Providing 50 mm thick Cement Concrete M20 (1:1.5:3) raintaining slope in alternate 2 mIx 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and clcaned sand of F M 2 5 io 3 including screening,shuttering,and mixing cerite nt c0ncrete in mixer with admixture of integral water proofing and placing rn position,strikirrg cLrring,t-a]glgnd royality all complete as per buildirrg specifictionJand direction of E/l.Panels that has been left should be casteci nextday.-lhere should be 6 mm gap between Panels.Brand- Sika *Plastocrate plus,MYK proof WP10, Fosroc- Conplast X421ic , Dr Frx,t Prdiproof LWr |
| 115 | Provrding and filling of Groove between 50 mm PCC Panels with Polyshlphide Sealant (Poring Grade)as per drawings and Technical specifications and dii-ection of E in Charge (with 1B% GST).Brand:-Sika- Polysulphide, Fosroc-l-hioflex 600 Dr. Fixit Pidiseal PS(42P),MYK Seal PS or Euivallent |
| 116 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design |
| 117 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement laster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 118 | FINISHING WORK |
| 119 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
| 120 | Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of FM 1.5 with 5% cico or any other approved water proofing compound including screening, curing, with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 121 | Providing 19 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 122 | Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
| 123 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 124 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Old work ( one or more coats) |
| 125 | Providing two coats of plastic emulsion paint of approved shade and make over old surface including washing cleaning and preparing the walls scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. |
| 126 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 SQM) over and including priming coat of exterior primer applied @ 2.20kg/10 SQM |
| 127 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coat applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 128 | Providing two coats of synthetic enamel paint of approved shade and make over new wooden surface including cleaning the surface after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 129 | Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 130 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. |
| 131 | (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. |
| 132 | (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. |
| 133 | WALL CLADDING WORK |
| 134 | Supply and installation of PVC sheet flooring 2 metre wide and overall thickness of 2mm of Armstrong/ Forbo/ Polyflor. The product should be homogeneous and single layered. The wear surface shall consist of impregnated polyurethane homogeneous mixture of PVCwith DIAMOND 10 technology, Plasticizers without DOP, Urethane, color pigments and filler calendered to form a sheet. Product shall conform to group \\"T\\" wear resistance as per EN 649, Flammability resistance of class Bfl-s1 as per EN13501-1, Dynamic coefficient of friction of class DS as per EN 13893, Impact sound reduction of 3dB as per ISO 10140, Slip Resistance of class R9 as per DIN 51130, Color fastness rating of ≥6 as per ISO 105-B02, total weight being 3.3 kg/m2 as per EN430. The product shall be suitable for applications in class 23/34/43 areas as per EN685. Product shall exhibit antistatic behaviour, resistance to bacteria,resistance to chemical, resistance to staining,suitability to castor chair. Equivalent to Armstrong Simpurity Installation- It is important to ensure the subfloor on which the sheet is being laid is smooth, flat, hard and free from moisture, grease etc. In case of uneven subfloor the same should be levelled using self leveling compound which will charged extra. The moisture present in the subfloor should be less than 8% before installation of the floor adhesive. The installation shall be undertaken as per manufacturers installation instructions. |
| 135 | Supplying and laying Indoor Anti-Bacterial paint over ceiling and as specified by EIC, equipped with Silver Ion Technology which kills 99% of infection-causing bacteria on the painted surfaces and providing a more hygienic environment. VOC (ASTM D 6886): < 50 gm/lit Does not contain carcinogens, mutagens, or reproductive toxins. Any trace contaminants should be less than 0.01% by weight. Certified by Indian Medical Association or any other competent organisation. (including putty, primer and other accessories) |
| 136 | CARRAIGE OF MATERIALS |
| 137 | SAND ( 10KM ) |
| 138 | CHIPS ( 22 KM ) |
| 139 | METAL ( 22KM ) |
| 140 | BRICKS ( 1+7KM ) |
| 141 | Epoxy bonding agents for bonding old Concrete & Repair materials |
| 142 | Providing and applying bond coat on the prepared surface with two component epoxy based bonding coat Nitobond EP of Fosroc make or equivalent, having specific gravity 1.15 to 1.2 gm/cc,. The bonding agent shall be applied by brush & should remain in tacky state after application for a minimum period of 5-6 hrs at 20 deg C & 2-3 hrs at 30 deg C. Laying of reinstatement polymer modified mortar or micro concrete shall be completed within the overlay time of bonding coat. |
| 143 | Provide and apply single-component, free-flowing, non-shrink cementitious microconcrete at a water-to-powder ratio of 0.15. The microconcrete should have a fresh wet density of 2200 kg/m³ at 27°C and an unrestrained expansion of 1 to 4% as per ASTM C827. It must achieve a flowable consistency and compressive strength of not less than 10 N/mm² after 24 hours, 35 N/mm² after 7 days, and 45 N/mm² after 28 days at 30°C. The cured microconcrete shall be free from metallic aggregates and chlorides, and it must be shrinkage-compensated in the plastic state. Payment will be based on the consumed dry material of the microconcrete mix (Product :- Renderoc RG 45 of Fosroc/ SikaRep® Microcrete -4 of Sika / MasterEmaco S-346 of BASF or equivalent of Pidilite)including the cost of centring and shuttering. |
| 144 | a) Without addition of aggregate |
| 145 | 20 passenger lift/1360 kgs /1.25 speed/ 3 floors/ 3 stopes stainless steel ( 1.5mm) car cabin |
| 146 | Demolishing of existing passenger lift in all complete as per engineer in charge. |
| 147 | INTERNAL EIECTRICAL WORK |
| 148 | Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box etc as required. Group C |
| 149 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group- C |
| 150 | Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, 2 way modular switch, modular plate, suitable GI box etc as required. |
| 151 | Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 152 | Wiring for light/ power plug with 4X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 153 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required |
| 154 | CIRCUIT / SUBMAIN WIRING |
| 155 | 2x1.5 sq mm + 1x1.5 sq mm earth wire |
| 156 | 2x2.5 sq mm + 1x2.5 sq mm earth wire |
| 157 | 2x4 sq mm + 1x4 sq mm earth wire. |
| 158 | 2x6 sq mm + 1x6 sq mm earth wire. |
| 159 | 4x10 sq mm + 2x6 sq mm earth wire. |
| 160 | 4x16 sq mm + 2x6 sq mm earth wire. |
| 161 | COPPER RE-WIRING IN EXISTING CONDUIT |
| 162 | TWIN CONTROL POINT RE-WIRING IN EXISTING CONDUIT |
| 163 | Rewiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in existing surface / recessed Steel/PVC conduit including dismantling as required. |
| 164 | WIRING IN EXISTING CONDUIT |
| 165 | Supplying and drawing following sizes FR PVR insulated copper conductor single core cable in existing surface / recessed Steel/PVC conduit including dismantling as required. |
| 166 | 2x1.5 sq mm |
| 167 | 2x2.5 sq mm |
| 168 | 2x4 sq mm |
| 169 | 2x6 sq mm |
| 170 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 171 | 1 run of cable |
| 172 | 2 run of cable |
| 173 | 3 run of cable |
| 174 | Supplying and fixing of following sizes of PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 175 | 20mm dia |
| 176 | 25mm dia |
| 177 | 32mm dia |
| 178 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 179 | 20mm dia |
| 180 | 25mm dia |
| 181 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 182 | 5/6 amps one way switch |
| 183 | 15/16 amp one way switch |
| 184 | 5/6 amp 3 pin socket outlet |
| 185 | 5/16 amp 6 pin socket outlet |
| 186 | Telephone Socket Outlet |
| 187 | TV anteena Socket Outlet |
| 188 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 189 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 190 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. |
| 191 | 1 or 2 Module (78mm x 78mm x 45mm) - For Telephone & TV outlet. |
| 192 | 4/5 Module (78mm x140mm x 50mm) |
| 193 | 6 Module (78mmX205mmx50mm) |
| 194 | 8/9 Module (78mmX230mmx60mm) |
| 195 | 12 Module (135mmX205mmx60mm) |
| 196 | Supplying and fixing Ding dong sound call bell single phase, 230 volts, complete as required. |
| 197 | Installation, testing and commissioning of pre wired fluorescent fitting / Compact fluorescent fitting off all type complete with all accessories and tube etc directly / wall including connection with 1.5 sq.mm FR PVC insulatted. copper conductor single core cable and earthing etc. as required. |
| 198 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, etc. as required. |
| 199 | Installation of exhaust fan up 450 mm sweep in the existing opening including making the hole to suit the size of above the fan, making good the damage, connection, testing, commissioning etc. as required. |
| 200 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 201 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). (For UPS Supply) |
| 202 | Supplying and fixing following ways, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 203 | 6 Way (4+18), Double Door Horizontal Type |
| 204 | 8 Way (4+24), Double Door Horizontal Type |
| 205 | Supplying and fixing following ways surface / recess mounting Vertical type 415 Volts TPN MCB distribution board, of sheet steel dust protected duly power painted inclusive of 200 Amps tinned copper bus bar common, neutral link, earth bar, din bar, for mounting MCB's (But without MCB's and incomer) as required. ( Note:- Vertical Type MCB TP DB is normally used where 3phase outlets are required. |
| 206 | 8 Way (4+18), Double Door Vertical Type |
| 207 | 12 Way (4+24), Double Door Vertical Type |
| 208 | Supplying and fixing 6 Amp to 32 Amp rating 240 volts, 10 KA \\"C\\" Curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc.,as required. |
| 209 | 6 / 32 Amp Single Pole |
| 210 | 50/63 Amp TPN |
| 211 | Supplying and fixing Single pole blanking plate in the existing MCB DB complete etc. as required. |
| 212 | Supplying and fixing of following rating four pole ( three phase & neutral), 415 volts, residual current circuit breaker (RCCB), having a sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc as required. |
| 213 | 40 Amps |
| 214 | 63 Amps |
| 215 | 125 Amps |
| 216 | Supplying and fixing Cable End Box (Loose wire box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415V, on surface/ recess, complete with testing and commissioning etc. as required. |
| 217 | For 6 way, Double door TPN MCBDB |
| 218 | For 8way, Double door TPN MCBDB |
| 219 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required. |
| 220 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required. |
| 221 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required |
| 222 | SUPPLY & INSTALLATION OF LIGHT FIXTURES & FANS |
| 223 | SITC of following rating recess / surface mounted LED round / square shape down light luminarie with pressure die cast housing for single phase supply voltage Luminarie shall be confirm to IS: 10322 part -5 / section -2 or IEC :62722 withh all neccesary accessories as required. |
| 224 | 12 W LED Round Down Light |
| 225 | 18 /20 W LED Round Down Light |
| 226 | 2' x 2' LED Panel Light |
| 227 | Bulk Head fitting with 9/10Watt LED. |
| 228 | S.I.T.C of following rating surface mounted LED Tube Lighting Fitting Suitable for 230V 50 Hz, Single Phase Supply etc. complete as required. 20/22 W LED Tube Light |
| 229 | SITC of 300 mm (12\\") Exhaust fan (Metal body) suitable for single phase 230 volts, 50 Hz., AC supply complete with motor, louvers/shutters etc. complete as required. |
| 230 | Supply Installation, Testing & Commissioning of following sizes ceiling fan 3 Blades confirming to IS:374:2019 including wiring the down rods of standard (up to 30cm) with 1.5 sq.mm FR PVC insulated copper wire suitable for 230V 50 Hz, Single phase supply etc. complete as required. 1200 mm ( 48\\") BLDC 5 Star rating 32W Ceiling Fan |
| 231 | HIGH MAST |
| 232 | Supply of 20mtr. High mast in two section Construction 5355 grade as per BIEN 10 025 Top Dia 150mm, bottom dia 410mm, plate thickness 3mm,2Oside polygon, galvanisation as per BS EN ISO 146L, base plate dia 570mm, base plate thickness 25mm, GI single spike lighting protection, maximum wind speed 47 m/swith 8 nos foundation bolts of PCD 490mm TS 600/ 30mm dia/850 mm long. Luminaries carriage : Material for 50 NB ERW Class B - M.S. Pipe, dia of carriage ring 535mm (ID) with 6 arm, welded,2 sections having carrying capacity upto 12 luminaries. Trailing Cable : 5 core 4sq.mm. PVC flexible copPer conductor Winch/Power Tool : Double drum, SWL 750 kg with 1HP 6 pole single speed integral motor Rope : Grade A13131'6,7 /19 construction, dia 6mm, BLC 2350 x 2 having 2 nos of continues roPe. Aviation obstmction light: twin dome aviation obstruction lights LED type as required. (But excluding Feeder Pillar) |
| 233 | For 20 mtr. High mast: ITC of the high mast and light fixture with thehelp of suitable tools and plans, wiring of luminaries with all Wiringmaterial like PVC insulate[Pvc sheathed flexible cable of suitlblbcopper conductor lugs, MCB and all labour & construction of shallow foundation with M25 grade concrete for the high mast considering safe soil bearing capacity of 10T / mhs sq. for 20 M High mast. |
| 234 | S.I.T.C of floowing rating LED Street lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protecdon) ln odsttng pole/pipe for supply voltage \WTIY AC, 50H2. Luminarie shall be confirm to IS: 1(E22 part-5/secdon-3 and shall be complete with all neccssary accessories as required. ( LED FLOOD Light 240W) |
| 235 | LED SOLAR STREET LIGHT |
| 236 | Supply and Installation of LED SOLAR STREET LIGHT 75Watt Peak.Battery capacity-≥ 12.8 V (nominal), 30 Ah at STC (1 day autonomy).Type of LED (Light source)20 Watt White LED type.Ingress protection-IP65 or better.Nominal bore size of tube -40 mm / 3.2 mm.Height of pole (in m) - 6.Battery box-Outside the luminaire enclosure in a vented, acid proof and corrosion resistant, hot dip galvanized metallic box (IP65 or better) with anti-theft locking arrangement for outdoor use.Type of PV Module-Only indigenous modules of IEC Tested used. Crystalline high power/efficiency cells used in the solar photovoltaic module.Power output of PV Module-≥ 75 Wp at 16.4 ±0.2 Volt at STC.PV Module Efficiency-≥ 14%.The open circuit voltage of the PV modules under STC (in volts)- 21.Type of Battery-Lithium Ferro Phosphate battery (LiFePo4). Operating from dusk to dawn first four hour full brightness, rest of the time at lower level, with motion sensor.Battery capacity-≥ 12.8 V (nominal), 30 Ah at STC (1 day autonomy).Cycle/ Current-Battery cycle life 2000 cycle at 80 % discharge.Type of led-20 Watt White LED type .LED chip Efficacy (Lumen/watt)-≥135.Luminaire System Efficacy - Lumen output - (Lumen/watt)-≥120. The color temperature of white LEDs used in the system-5500 degree K – 6500 degree K.The temperature of heat sink-≤ 20 degree centigrade above ambient temperature during operation.CRI-> 70 %.Lighting quality-Free from glare, flickering and UV.Wattage-Power consumption of the LED Luminaire / Lighting unit ≤ 30W (including LED and Driver power loss) |
| 237 | .Ingress protection-IP65 or better.Provision of Fuses-Fuses provided to protect against short circuit conditions. Protection-Full protection against open circuit, accidental short circuit and for reverse polarity provided.The self consumption of the charge controller-≤ 20 mA at rated voltage and rated current.Total electronics efficiency-≥ 90 %.Provision on frame structure-Frame structure have provision that the module can be oriented at the suitable tilt angle.Conformity of the specification for Steel tube for street light pole-as per IS:1161:2014 latest.Hot dip galvanized condition the zinc coating on the tubes-as per IS:4736 latestNominal bore size of tube / Thickness of tube-40 mm / 3.2 mm.Battery box-Outside the luminaire enclosure in a vented, acid proof and corrosion resistant, hot dip galvanized metallic box (IP65 or better) with anti-theft locking arrangement for outdoor use. All Work as per E/I. |
| 238 | SANITARY INSTALLATIONS |
| 239 | Supplying , fitting and fixing vitreous white glazed earthen ware I.W.C of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I 'p' trap 15 liters C.I.pull and let go flushing cistren of names or other I.S.S. equivalent make , complete with all fitting , C.I.or C.C. brackets 32mm alkathene/P.V.C telescopic flush , pipe about 2 M long with one brass coupling and clamps GI ,chain and pull including supplying and fixing a pair of vitreous white glazed earthenware ware footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less thane 50grms. 15mm P.V.C. connection pipe 450 mm. long and the exposed pipe and cistern with two coats of approved paint over a coats of red oxide primer etc. all complete as per specification and direction of E/I. |
| 240 | (A) 580 mm. long |
| 241 | (c) With 10 lit. low level PVC Cistem |
| 242 | Supplying, fitting and fixing 40mm high vitreous white glazed earthen E.W.C. with ‘p’ trap of parry hindustan or any other approved I.S.S. make including supplying and fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I.handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450grams 15mm P.V.C. alkathene pipe 45cm. long with brass coupling at both ends and white/black plastic solid state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming, all completeas per specification and direction of E/I. |
| 243 | (ii) E.W.C. with 'S' trap |
| 244 | (b) 10 lit. low level PVC Cistem |
| 245 | Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I.brass waste, 15 mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I. |
| 246 | (b)Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror. |
| 247 | (i) 600mm x 450mm size |
| 248 | (c)(iii) C.P. brass liquid soap container |
| 249 | Provinding and fixing wash basin wih C.I brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls whereever required : White Vitreous China Wash basin size 550x400 mm with a 15mm CP Brass single hole basin mixer |
| 250 | Providing and fixing white vitreous china laboratory sink with CI brackets , C.P brass chain with rubber plug 40 mm C.P brass waste and 40 mm CP brass trap with necessary C.P brass unions complete including painting of fittings and brackets , cutting and making good the wall wherever required : Size 600x450x200 mm |
| 251 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in charge. |
| 252 | Providing & fixing PVC waste pipe for sink including PVC waste fitting Complete Flexible Pipe 32mm Dia |
| 253 | Providing and fixing toilet paper holder : C.P. brass |
| 254 | Providing and fixing PTMT Bottle Trap for Wash basin. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. |
| 255 | Providing & fixing PTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealed fittings arrangement of approved quality and colour weighing not less than 88 gms |
| 256 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore |
| 257 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore |
| 258 | Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms |
| 259 | Providing and fixing CP brass single lever low flow Sink mixer with 15 mm CP brass single lever pillar cock with pop up and waste complete including cutting and making good the walls where required.ROCA make (Model -RT5A3060C00) or Equivalent. |
| 260 | Providing and fixing C.P concealed four way diverter with thermostatic mixer with shut off valve and diverter, including cutting and making good the walls, wherever required. (Make:- Jaquar - Four way diverterKUB-35421, Thermostatic mixer 35671 or Equilent) |
| 261 | Providing,Fixing satin finish stainless steel AISI 316 grade wall mounted coat hook on door complete. The rate include cost of all material & labour involved in the item complete and all as per direction of engineer incharge. MAKE JAQUAR MODEL NO.- ACN-1161N or EQUIVALENT. |
| 262 | DRAINAGE INSTALLATIONS |
| 263 | Providing, fixing, testing and commissioning of UPVC SWR pipe type 'B' conforms to IS : 13592-1992 with all fittings such as bends, tees, elbow, 'Y', offset, cleaning pipe door, clamps etc. conforming to IS:14735-1999 and steel structural supports etc. including cutting the floors, walls and making good the same in cement concrete 1:2:4 & cement mortar 1:4. The wall thickness of pipe and technical characteristic conforms to IS : 13592-1992 type 'B'. The fitting dimension conforming to IS : 14735-1999. The jointing to be completed with rubber ring joint/solvent weld joint as required/applicable. 110 mm (OD) |
| 264 | Providing, fixing, testing and commissioning of UPVC 'P' trap/floor trap/urinal trap of self cleansing design having 50 mm water seal with or without horn conforming to IS : 14735-1999 including setting with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 hard stone ballast 20 mm nominal size) including cost of cutting and making good the walls & floors wherever required. 110 mm inlet x110 mm outlet. |
| 265 | Providing, fixing, testing and commissioning of UPVC inlet fittings (hopper) receive waste from fixture waste with maximum 3 inlets 40, 50 & 63 mm OD size, fabricated from 110 OD UPVC SWR pipe, UPVC sockets, fixed to UPVC traps including solvent weld joint/rubber ring joint, complete with all civil work set in cement concreate 1:2:4 as required including cost of cutting and making good the walls & floors wherever required. |
| 266 | Providing, fixing, testing and commissioning of UPVC waste Pipe conforming to IS : 4985-2000 class III including all moulding fittings conforming to IS : 7834 (Part-1 - Part -7) 1987 such as tees, bends, reducers, coupling, adopters etc. solvent welded joint as per manufacturer recommendation including cutting and making good the walls, floors, R.C.C. work etc. (For fixtures waste). |
| 267 | 40 mm (OD) |
| 268 | 50 mm (OD) |
| 269 | Providing and fixing UPVC floor drain including all fitting and accessories fixed in cement mortar complete in all respect. 110 mm OD x 63 mm OD |
| 270 | Providing and fixing MS holder bat clamps of approved design to cast iron (spun) pipe embedded in and Including cement concrete blocks 10 x10 x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. For 100mm dia. Pipe |
| 271 | Providing and fixing PTMT grating of approved quality and colour. 125 mm nominal dia with 25 mm waste hole |
| 272 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) alround 100mm dia. SW / CI / waste pipes including bed concrete as per standard design |
| 273 | Providing, fixing, testing and commissioning of UPVC rain water pipes (IS : 4985-1983 class-III ) including injection moulded fittings (heavy duty) (plain or door) e.g. bends, junction, cowls, tees, offsets, access pieces etc. Clamps/Supports jointing with rubber ring/solvent cement joints including cutting chase or holes in walls and floors and making good as required at Site [For Balcony Drain + Terrace Rain Water Downtake Pipe]. 160 OD |
| 274 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 275 | WATER SUPPLY INSTALLATIONS |
| 276 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 277 | Providing and fixing G.I. pipes complete with GI fittings and clamps including cutting and making good the walls etc. (Exposed on wall Terrace) |
| 278 | 32 mm dia, nominal bore |
| 279 | 40 mm dia, nominal bore |
| 280 | Making connection of GI distribution branch with GI main of 50-80mm nominal bore by providing and fixing tee, including cutting and threading the pipe etc. complete. 25 to 40 mm nominal bore |
| 281 | Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends) |
| 282 | 25 mm dia, nominal bore |
| 283 | 32 mm dia, nominal bore |
| 284 | 40 mm dia, nominal bore |
| 285 | Painting GI pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality |
| 286 | 32 mm dia, nominal bore |
| 287 | 40 mm dia, nominal bore |
| 288 | Providing and fixing G.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete. |
| 289 | 20mm nominal bore |
| 290 | 25mm nominal bore |
| 291 | 32mm nominal bore |
| 292 | 40mm nominal bore |
| 293 | Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 15mm nominal bore |
| 294 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm dia nominal bore |
| 295 | Provide and fixing PTMT ball cock of approved quality, colour and make complete with epoxy coated aluminium rod with L.P/H.P.H.D. plastic ball 50 mm dia NB, 242mm long. Weighing not less than 1240 gms. |
| 296 | Providing and fixing chlorinated poly vinyl chloride (CPVC) pipes having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fitting, including fixing the pipewith clampsat 1 m spacing. This includesjointing of pipes &fittingwith one step CPVC solvent cement and cost ofcutting chases and making good the same including testing ofjoints complete as per direction of Engineer in Charge.(Concealed work including cutting chases and making good the walls etc.) |
| 297 | 15mm nominal outer dia. Pipes. |
| 298 | 20mm nominal outer dia. Pipes. |
| 299 | 25mm nominal outer dia. Pipes. |
| 300 | Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 50mm diameter |
| 301 | Butterfly valve (manual) with C.I body SS disc nitrile sheet & O ring & PN 16 Pressure rating as specified 100 mm nominal bore 50 mm dia. |
| 302 | Providing, laying, Jointing, Testing and commissioning of uPVC pressure pipes of 10Kg/Sqcm pressure rating class 5 (IS : 4985-2000) including fittings, tees, bends, clamps, coupling and adaptors supports, and jointing with solvent joint, testing and necessary earth work in excavation, backfilling, disposal of surplus earth with a lead upto 50m complete, compaction and consolidation Including laying cement concrete 1:2:4 alround UPVC pipe including bed concrete and thrust blocks at bends as per standard design. 32 OD mm. |
| 303 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 304 | Constructing masonry Chamber 60x45x50 cm,inside with 75 class designation brick work in cement mortar 1:5 (1 cement:5 fine sand) for water meter complete with C.I. Doble flap surface box 400x200x200mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size) necessary excavation foundation concret 1:5:10 (1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. With F.P.S. bricks |
| 305 | SEWERAGE & DRAINAGE INSTALLATIONS UPTO MAIN ROAD FIRST MANHOLE |
| 306 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: |
| 307 | 150 mm diameter |
| 308 | 200 mm diameter |
| 309 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : |
| 310 | 150 mm diameter S.W. pipe / RCC pipe |
| 311 | 200 mm diameter S.W. pipe / RCC pipe |
| 312 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 180 x 150mm size P-type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 313 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 250 mm dia. R.C.C. pipe |
| 314 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : |
| 315 | Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensiions total weight of cover and frame to be not less than 38 Kg. ( weight of cover 23 Kg. and weight of frame 15 Kg.), with FPS bricks with class designation 7.5 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 316 | Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 317 | Extra for depth for manholes: Size 90 x 80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 318 | Size 120x90 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 319 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
| 320 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : |
| 321 | For pipes 100 to 250 mm diameter |
| 322 | For pipes 350 to 450 mm diameter |
| 323 | Constructing brick masonry road gully chamber 50x45x60cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450mm precast RCC horizontal grating with frame complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 324 | MODULAR OPERATION THEATRE |
| 325 | EGP. puff panels for O.T wall walls |
| 326 | Supply, installation, testing and commissioning of modular OT Walland corner panels with insulated prefabricated puff Panels. The OT wall shall be constructed using EGP puff panels having 0.8 mm thick GI sheets on both sides. These panels should have been produced in a double band laminator, in which two continuously moving belts carrying 120 GSM galvanized steel sheets of 0.80 mm thickness are firmly bonded together by sprayed -in insulating foam, which hardens during the process. The core consists of rigid polyurethane foam, which has been injected under high pressure, with a minimum density of 40kg/m3. The thickness of Puff shall be minimum 40 mm. The sheet panel shall be of indigenous reputed make and be provided with manufactures test certificate. The puff panel shall be fixed to the floor with bottom track of 1.5 mm thick steel U channel section having min size of 50mm X 50mm. The bottom shall be fixed in the floor of the OT with 10mm thicknessand min. 60 mm long SS fasteners which shall be fully threaded and power drilled. The Panels of walls and ceiling shall be tied together by suitable SS coving. The individual wall panels of wall and ceiling shall be tied together by suitable SS coving. The individual wall panels shall be welded together by SS. All joints shall be filled with metal filler and shall be sand casted on site till smooth finish is obtained. Wall & panel joints shall not be visible after the final wall coating is applied. The gap between the masonry wall surfaces and the panel of the theatre shall be sufficient for the flush mounting of This gap shall be provided to accommodate the equipment at a latter date and to enable services, pipes conduits etc, to be run within the gap. All wall-mounted equipment shall be flush mounted and sealed in operation theatre. All the sharp edges and corners shall be in radius to avoid bacterial contamination. The wall panel design shall be such that it enables the installation and supports all openings required for the installations shall not affect rigidity and strength of the panel. Access boxes shall be fitted to the rear of all wall-mounted equipment to enable maintenance to be carried out from outside the operation theatre. Product should have warranty of at least 10 years. The work should be executed as per the directions of Engineer in-Charge. |
| 327 | G.I. puff panels for OT ceiling |
| 328 | modular OT ceiling panels with insulated prefabricated puff Panels. The OT ceiling shall be constructed using GI puff panels having 0.8 mm thick GI sheets on both sides. These panels should have been produced in a double band laminator, in which two continuously moving belts carrying 120 GSM galvanized steel sheets of 0.80 mm thickness are firmly bonded together by sprayed -in insulating foam, which hardens during the process. The core consists of rigid polyurethane foam, which has been injected under high pressure, with a minimum density of 40kg/m3. The thickness of Puff shall be minimum 40 mm. The sheet panel shall be of indigenous reputed make and be provided with manufactures test certificate. The puff panel shall be fixed to the floor with bottom track of 1.5 mm thick steel U channel section having min size of 50mm X 50mm. The bottom shall be fixed in the floor of the OT with 10mm thicknessand min. 60 mm long SS fasteners which shall be fully threaded and power drilled. The Panels of walls and ceiling shall be tied together by suitable SS coving. The individual panels of wall and ceiling shall be tied together by suitable SS coving. The individual wall panels shall be welded together by SS. All joints shall be filled with metal filler and shall be sand casted on site till smooth finish is obtained. Wall & panel joints shall not be visible after the final wall coating is applied. The gap between the masonry wall surfaces and the panel of the theatre shall be sufficient for the flush mounting of This gap shall be provided to accommodate the equipment at a latter date and to enable services, pipes conduits etc, to be run within the gap. All wall-mounted equipment shall be flush mounted and sealed in operation theatre. All the sharp edges and corners shall be in radius to avoid bacterial contamination. The wall panel design shall be such that it enables the Provision of openings required for the installations shall not affect rigidity and strength of the panel. Access boxes shall be fitted to the rear of all wallmounted equipment to enable maintenance to be carried out from outside the operation theatre. Product should have warranty of at least 10 years. The work should be executed as per the directions of Engineer in-Charge. |
| 329 | Antibacterial / Antifungal Paint. |
| 330 | Providing and establishing anti-bacterial & anti fungicidal sterile coating of liquid plastic paint on GI Puff/SS panel of modular OT. The paint should be seamless, easy to clean, should have vapor permeability which allows substrate moisture to escape and protects against growth of bacteria, mound and yeasts, moisture resistance, freeze / thaw resistance. Anti-bacterial anti microbial quality should remain active throughout the life of the product. Vapors permeable structure should allow damp substrates to dry out without causing blistering. It should tolerate cleaning with hospital chemical agents. Filling of all joints and cavities should be with metallic epoxy filler and sand casted flush to provide a joint-less finish. This should include all fittings, accessories, hardware, support structures, etc. required for installation. Anti-bacterial and anti-fungus sterile coating shall be applied on the finished walls & ceiling with at least 2-3 coats to achieve a thickness of minimum 200 micron. Before application of sterile wall coating an appropriate primer shall be applied. The primer shall be supplied along with the paint and should be of the same make as that of paint. and shall be applied prior to coating of anti-bacterial & anti- fungus sterile paint on walls & ceiling 2-3 coats shall be applied to achieve a thickness of 200 microns. Sterile coating and primer shall be applied on the surface by air-less spray gun. Sterile coating shall withstand against application of commonly used cleaners in the operation rooms and shall withstand against regular steam cleaning. Product should have warranty of at least 10 years. The work should be executed as per the directions of Engineer in-Charge. |
| 331 | Laminar Air Flow |
| 332 | The range of ventilated ceiling should provide the sterility and cleanliness required for OT environ ment. Perfect tightness should be guaranteed by a n epoxy seal between filters and holding structure disabling “by pass†of HEPA filters. Two nos . pressure measurement ports shall be provided in each HousingAirflow: 50 +-10% FPM Class 100/ISO c lass 5 as per international standard & meets DIN 1 946-4. D.O.P. tested point to p oint scanned MINIPLEAT HEPA FILTERS having followi ng technical specifications to be fixed in above H ousings F rame – Aluminium. Type – Flange Type. Media – Micro Fiber Glass . Se aling of media – By means of epoxy. I.P.D. -< 15 mm WG. F.P.D. – 50 mm WG. Separators – Concealed Al. or Hot melt G lue. Capacity – 500 CFM Size of LAF - 2400 x 2400 mmThe work should be executed as per the direction of Enginee r in charge |
| 333 | Homogeneous Conductive PVC Vinyl Flooring in O.T.,ICU. |
| 334 | Providing and fixing 2 mm thick homogeneous conductive PVC JEOFlor Electro + SD Roll acts as a Continous Conductive 10^6 |
| 335 | Writing White Board. |
| 336 | Supply & Installation of writing unit/white boardof size 900/600 mm having 1.60 mm thick white laminate board top, bonded to a 40 mm high density fiber board sheet for additional rigidity. The unit should open to create a wall mounted writing surface within the operating room. The work should be executed as per the direction of Engineer-in-Charge. |
| 337 | Storage Unit . |
| 338 | Supply and installation of storage unit of SS 304of reputed make and having size 1665 x 865 x350 mm and having two or more glass shelves of toughened glass 10 mm thick, supported with D type bracket (SS 304 grade) with 10 mm thickness and rubber gasket of 2mm and mounted flush on wall. The work should be executed as per the directions of Engineer–in-Charge. |
| 339 | Pressure Release Damper. |
| 340 | Supply, installation, testing & commissioning of SS Fabricated Cascade pressure stabilizer having SS blades to control Operation Theatre Room - Air Pressure of approved make as per tech. specs attached. |
| 341 | Peripheral Lights (Dimmable). |
| 342 | Supplying & fixing of sturdy writing board of size: 840mm x 640mm with perfect marker writing surface in front and back is laminated to make water proof surface. The board has to be provided with anodized aluminium framing and its back should have hooks for wall hanging of approved make and type directly on wall & |
| 343 | AHU With Outdoor Unit AC11.5 Tr including Insttalation |
| 344 | DOUBLE SKIN AIR HANDLING UNIT :Supply, installatio n, testing and commissioning of double skin constr uction AIR HANDLING UNITS. With inner Sheet SS 304 and Ouer sheet PPGI with 40 mm Panel Thickness with mixing box with FA,RA,SA dampers, fitted with 2 stage filteration arrangment completed with 10 micron filters 5 mico nfilter after fan section. suitable for outdoor in stallation with 45 mm thick panels with inner skin 0.6mm thick aluminium sheet, thermal breack and w eather proof.Motor Efficiency Factor - IE-2â– Mix ing box with manually operated fresh & return air AL dampers.â– Filter section with 50 mm thick box type pre-filter (MERV-8) & 305 mm thick rigid med ia type fine filter (MERV-10) mounted on a common filter frame & Viscous/ wasable synthetic type air pre-filterâ– Coil section with 8 Row deep DX coi l . Fin Material - Plain Aluminium Fin spacing - 1 1-13 FPI, Condensing tray - 22G SS304, Test Pressu re - 38Kg/Sq.cm. Insulation Material for Drain Tra y-13mm thick close cell Nitrile Rubber.â– UV Lamp |
| 345 | Aluminum Ductiing 22 Gaze |
| 346 | Ducting : ( Al. sheet metal )Ducting:- Supply and fixing of site fabricatedAl sheet metal ducts in a ccordance with theapproved shop drawings and as re quired as per specifications.All necessary GI /MS supports using thread rods (as directed). Angle, f lat, and anchor bolts, food grade neoprene gaskets , food grade adhesive included in the scope. |
| 347 | Insulation |
| 348 | UNDERDECK INSULATION :Supplying and fixing of unde rdeck roof insulation of 13 mm thickness of mat fi nish closed cell Antimicrobile nitrile rubber ( cl ass 'O' ) insulation on existing surface after app lying two coats of cold setting adhesive as requir ed. |
| 349 | !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! |
| 350 | Surgical Scrub (2 Bay). |
| 351 | Supplying, fixing installation, testing andcommissioning of scrub sink with the following specifications:- Compact surgical scrub sink should be designed for use in OT complex for pre procedural scrub up. (Double sink combination size 1600 mm X 450mm X 1650 mm back height& 1200 mm and front heightas suitable) • Each fixture should be fabricated from heavy gauge type 304 stainless steel (minimum thickness1.5mm) and should be seamless welded construction, polished to a satin finish • The scrub sink should be provided with a front access panel which should be easily removed for access to the water controlled valve, waste connections, stoppers and strainers.• Hands free operation should include infra-red sensors with programmable adjustment.• Thermostatic mixing, valve control should be located behind the access panel and maintain constant water temperature.• Timing should be adjustable to meet individual application requirements.• Provided with infrared sensors, thermostatic control taps with feel safe temperature controls with foam flow attachments and provide with Betadine dispensers .• All units should have reduced anti- splash fronts. • Knee/foot operated switch should be provided additionally. The work should be executed as per the directions of Engineer–in-Charge. |
| 352 | !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! |
| 353 | Sliding Type Hermitically sealed OT Door (Manual) |
| 354 | Supply & fixing of sliding type OT door having high density particle board cores, high pressure laminate face on both sides, viewing window 300 x 300mm.Standard Size: 1500 x 2100 mm (W x H) |
| 355 | Surgeon Control Panel. |
| 356 | Supply, installation, testing & commissioning of multi colour coded Surgeon Control Membrane Touch Panel, flushed in the theatre wall comprising of the following features & as per technical specification attached:1. Display of Day Clock2. Display of Elapse Time Clock3. Dimmer for peripheral lights4. Medical Gas Alarm5. Hands free telephone6. Indicator for temperature & Humidity. |
| 357 | X-Ray View Screen. |
| 358 | Supply, installation, testing & commissioning of Twin Plate X-Ray viewing screen designed to provide a high level of control luminance without Flickering & as per the technical specification attached.X-ray view screen (two screen) LEDOverall dimensions (LxHxT) 880 x 503 x 29mmView area (WxH) : 736 x 440 mmLight source : LEDPower consumption / input power : 30W / AC 100-240VIllumination intensity : 5,500 LUX approx. |
| 359 | Surgeon Pendent |
| 360 | Providing & fixing of Singale arm multi moveable surgeons pendant with load carrying capacity of 80Kg and rotational values of 330-340 degree with adjustable stopper. The pendent should be designed with service head to host, base, gas module, electric modular and shelves upto 8 gas outlets & 10 Electrical switches. Racks & Shelves should be provided to mount the equipments like monitor etc. The surgeon pendent should have two arms |
| 361 | Anaesthesia Pendant . |
| 362 | Providing & fixing of single arm (900mm) anaesthesia pendant with load carrying capacity of 80Kg and rotational values of 330-340 degree with adjustable stopper. The pendent should be designed with service head to host, base, gas module, electric modular and shelves upto 8 gas outlets & 10 Electrical switches. Racks & Shelves should be provided to mount the equipments like monitor etc. The surgeon pendent should have two arms |
| 363 | Multi Purpose OT Table with C - Arm Compitable |
| 364 | Cognate SS- is a sophisticated yet economical Operating Table Remote Control specially designed for 'C' ARM Image Intensifier. Its unique design permits it to excel over competitive offering in the areas of Micro-Neuro, Orthopaedics, Cardiovascular, Ob/Gyn, Ophthalmology, ENT, Urology and other major or minor operations, The Electro-Mechanical driving mechanism assures smooth and quiet movements of the Table Top. The Table Top is made of Radio-Translucent material for Fluroscopic capability, Operating Positions including Height Adjustment, Trendelenberg, Reverse Trendelenberg, Lateral Tilt and Back Section can be controlled quickly and accurately with the help of lightweight Hand Control Unit, The excentrically positioned Table Top, without cross members, to optimize image intensifier accessibility for both A/P & Lateral Exposures Standard Accessories L-shaped Anaesthetic Frame Shoulder Support with Pad Arm Board with S.S Top Lateral Support with pad Wrist Strap Knee Crutches Goepal Type Water proof Rubber Mattress 1 Pc. 1 Pair 2 Pcs. 1 Pair 1 Pair 1 Pair 1 Set |
| 365 | LED Operating Light |
| 366 | Providing & installation of LED operating light having Maximum illuminance (1m): 160,000 + 160,000 Lux at 1m distance, Electrical power: 150 + 90 W, Power consumption: 2x 11 A, Fitting: Ceiling anchoring ring ceiling pendant with 2 brackets and 2 spring arms, Range of movement: 1x 360° / 1x 330°, Recommended room height: at least 2.45 m, Max. ceiling load: 2x 218 Nm / 650 N, Light body weight: 9.2 + 7.5Kgs, Light body depth: 1x 130 cm / 1x 140 cm, Air shielding surface: 2 x 330 cm2 Transformers: 2x 450VA/230V/26V, Brightness regulator: 2x 20 – 500 VA (primary voltage), Provided with 2 Sterilisable handles with each dome, Easy positioning by sterilisable handle, Focus adjustable by sterilisable handle, Life time of Bulbs : 45,000 hours etc as per technical specifications attached |
| 367 | HORTICULTURE |
| 368 | Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment). |
| 369 | Supplying and stacking at site dump manure from approved source, including carriage up to 1.0 km (manure measured in stacks will be reduced by 8% for payment) |
| 370 | Screened through sieve of IS designation 20 mm |
| 371 | Screened through sieve of IS designation 16 mm |
| 372 | Screened through sieve of IS designation 4.75 mm |
| 373 | Supplying and stacking of well decayed cow dung manure at site including royalty and carriage up to 1.0 km (cow dung manure measured in stacks will reduced by 8% for Payment) |
| 374 | PREPARATION WORKS |
| 375 | Fine dressing of the ground |
| 376 | Mixing earth and sludge or manure in the required proportion specified or directed by the Engineer-in-charge |
| 377 | Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Engineer-in-charge (cost of sludge, dump manure and / or good earth to be paid separately). |
| 378 | Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts |
| 379 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) |
| 380 | Holes 1.2 m diameter and 1.2 m deep |
| 381 | Holes 90 cm diameter and 90 cm deep |
| 382 | Holes 60 cm diameter and 60 cm deep |
| 383 | Holes 45 cm diameter and 45 cm deep |
| 384 | MAINTAINANCE WORK |
| 385 | Complete maintenance of the entire garden features having as per yard stick in the garden area i.e. lawn trees, shrubs, herbs, edge, flower beds, foliages, creepers etc. including hoeing, weeding, pruning, replacement of plants, gap filling, watering, mowing of lawn, grass cutting by lawn mover and brush cutter, removal of garden waste, applying insecticide, pesticide & fertilizers (whenever required) top dressing of lawn with good earth and manure and maintenance of other garden related works as directed by office-in-charge (Cost of Good Earth, Manure, Fertilizer, Insecticide, Pesticide will be provided by the Department & lawn mover and brush cutter with fuel and other T & P material/articles shall be provided by thecontractor.) and as per direction of officer in charge. |
| 386 | TREES |
| 387 | Delonix regia Gulmohar / April fool |
| 388 | Cassia fistula Amaltash |
| 389 | Pterospermum acerifolium Makchund |
| 390 | Ficus religiosa peepal |
| 391 | Ficus benghalensis bargad / banyan |
| 392 | Cestrum nocturnum raat rani |
| 393 | Azadirachta Indica Neem |
| 394 | Bauhinia purpurea Kachnar |
| 395 | Callistemon lanceolatus Bottle brush |
| 396 | Spathodea campanulata rugtoora |
| 397 | Plumeria alba white champa |
| 398 | Plumeria rubra pink champa |
| 399 | Lagerstroemia flosreginae jarul |
| 400 | Polyalthia longifolia Ashok |
| 401 | Tectona grandis sal |
| 402 | Tamarindus indica Imli |
| 403 | Mangifera indica Mango |
| 404 | Eugenia jambolana Jamun |
| 405 | Phyllanthus emblica Amla |
| 406 | foxtail palm |
| 407 | Bottle palm |
| 408 | BAMBOO |
| 409 | Buddha belly bamboo |
| 410 | SHRUBS |
| 411 | Clerodendrum inerme Volkameria inermis |
| 412 | Ficus panda |
| 413 | Ficus benjamina Starlight Ficus Starlight |
| 414 | Gardenia jasminoides |
| 415 | Golden duranta |
| 416 | Hamelia patens |
| 417 | Hibiscus rosa-sinensis udhul |
| 418 | Raphis excelsa lady palm |
| 419 | Tecoma gaudichaudi Yellow bells |
| 420 | TMC dwarf Chandani |
| 421 | Canna dwarf |
| 422 | GROUND COVERS |
| 423 | Alternanthera red |
| 424 | Chlorophytum comosum |
| 425 | Jatropha |
| 426 | Sprenger's asparagus Foxtail fern |
| 427 | Syngonium podophyllum Syngonium butterfly |
| 428 | Tradescantia pallida |
| 429 | GRASS |
| 430 | Cynodon dactylon doob grass |
| 431 | Supply and Installation of Precast Concrete Reinforced Square Cement Flower Pots Material - CementShape (When viewed from Top) SquareArtistic /Decorative work on Pots YesPot Length (mm) 18 inchPot Width (mm) 18 inchPot Height (mm) 18.5 inch |
| 432 | Supply and Installation of Precast Concrete Reinforced Bench M-30 Grade concrete mix in accordance with IS : 10269/Latest in gray cement by using vibro - compaction technique and with reinforcement as detailed in Govng. specn. ach seating plank ( bottom ) of bench bolted with leg by help of 12 mm dia. X 65 mm length galvanized steel countersunk bolts with EVA washer – Backrest planks fitted with half threaded carriage bolts and nuts of size 165 mm X 8 mm dia with EVA & steel washer Seat / plank length ± 3 mm = 1500MMSeat height ± 3 mm = 450 MMSeat width ± 3 mm = 440 MM |
| 433 | Shifting of overhead utilities underground and upgradation of external electrical, ELV system, genset, stormwater and sewage drainage systems etc. with all complete job as per direction of E/I. |
| 434 | Add GST 18 % |
| 435 | Add Labour cess 1% Please Enable Macros to View BoQ information |