| Sl. No. | Item Description |
| 1 | Civil works |
| 2 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonary in 15cm layers with compaction including disposal of all surplus soil as directed within a lead of 30 meters complete in all respects & to entire satisfction of Engineer-in-Charge |
| 3 | Providing & laying Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type complete in all respects & to entire satisfction of Engineer-in-Charge |
| 4 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth complete in all respects & to entire satisfction of Engineer-in-Charge |
| 5 | Damp proof course 4cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at 1.65 Kg per sqm laid hot and sanded complete in all respects & to entire satisfction of Engineer-in-Charge |
| 6 | First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level complete in all respects & to entire satisfction of Engineer-in-Charge |
| 7 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth |
| 8 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 9 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 10 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 11 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. |
| 12 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 13 | Plastering on underside of ceiling 10mm thick cement plaster 1:3 |
| 14 | Scraping Cement plaster |
| 15 | 20mm thick cement plaster 1:4 in two coat work |
| 16 | 12.5mm thick cement plaster 1:4 |
| 17 | Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. |
| 18 | Providing and fixing 110 mm dia. SWR U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 19 | Providing and fixing 110 mm dia. SWR U.P.V.C Coupling/Sockets for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 20 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50 thick cement concrete 1:8:16 |
| 21 | Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3 |
| 22 | Providing and fixing in position gratings 150mm x 150mm for top Khura HCI grating. |
| 23 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing without cost of bitumen |
| 24 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 25 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material |
| 26 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm |
| 27 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix and finishing complete as per direction of Engineer-in-charge. Size 600x600 mm. |
| 28 | Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. |
| 29 | Providing and fixing beading to door and windows chowkats of commercial hard wood, such as Hollock, Champ, Chirassy Chaplash etc (Non coniferous timber other than teak conforming to ISI specification no 100., kiln seasoned) with iron screws, fixed in position complete as per design and shape required50mmx12mm |
| 30 | Providing and laying Polished Granite stone 18 mm thick flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 31 | Extra labour for projected nosing of stair case of any shape and design |
| 32 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. |
| 33 | Door and window frame of size 113mmx60mmx with 35mm wide single rebate |
| 34 | Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter. |
| 35 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 (a) Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-(iv) 35mm thick |
| 36 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt)For shutter area above 0.50 sqm |
| 37 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. completeI.S.I Designation No. III (size of door 851mm to 1000mm) |
| 38 | Providing and fixing 0.50mm thick aluminum sheet including cost of necessary fittings i.e. screws, etc. Complete |
| 39 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :300mm x 16mm |
| 40 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 41 | Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash-welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items) |
| 42 | Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects. |
| 43 | Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area |
| 44 | Extra for providing & fixing Steel beading of approved shape steel tube beading size 12mm X 12mm, 18 gauge of approved shape and section with screw for fixing of glass panes instead of glazing clips and metal slash putty in steel doors , windows & Ventilators complete in all respect |
| 45 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 46 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 47 | Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 48 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 49 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade including priming coat & preparation of surface. |
| 50 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade & applying priming coat with metal primer on new steel or iron work including preparation of surface |
| 51 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) : |
| 52 | For fixed portion and chawkhats |
| 53 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required |
| 54 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge.Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side. |
| 55 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item)Float glass panes of 5 mm thickness |
| 56 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece MS sheet outer box with slide plate and with stainless steel cover plate etc. complete as per the direction of Engineer-in-charge. |
| 57 | Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work.For fixed portion and chawkhatsFor shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required |
| 58 | Providing & fixing 100mm with Plate 150mm X 32 mm anodized aluminum Mat Finish handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. |
| 59 | Providing & fixing 250 X 10 mm anodized aluminum Mat Finish tower bolts ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. |
| 60 | Providing & fixing 150 X 10 mm anodized aluminum Mat Finish tower bolts ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. |
| 61 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminum doors including necessary cutting and making good etc. complete. |
| 62 | Providing Polyester Powder coating 50 micron any coloured specified to alumnum fittings various sizes including carriage of material from market to workshop & workshop to site of work..Tower Bolt 100mm to 300 mm Long |
| 63 | Providing Polyester Powder coating 50 micron any coloured specified to alumnum fittings various sizes including carriage of material from market to workshop & workshop to site of work..Handles all Sizes |
| 64 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) size 595x595 mm |
| 65 | Providing and Fixing ceiling consisting of 12.5mm thick Gypsum Board of any size G.I. Cradling hanged from the ceiling by means of G.I. hanger complete as per drawings,specifications and tothe entire satisfaction of engineer-in- charge. |
| 66 | Providing & fixing Outer logo of clinic |
| 67 | Providing & fixing Inner logo of clinic |
| 68 | Dismantling First class mud roofing |
| 69 | Dismantling of brick work, tile masonary of tile lining in cement |
| 70 | Dismantling reinforced cement concrete |
| 71 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. |
| 72 | Doors of area 3 sqm and below. |
| 73 | Windows of area 3 sqm and below |
| 74 | Dismantling cement conglomerate floors 25mm to 50mm thick without concrete base |
| 75 | Removal of malba with 5km lead |
| 76 | credit of brick bats |
| 77 | credit of old brick/tiles |
| 78 | credit of old steel scrap |
| 79 | credit of old doors |
| 80 | credit of old windows |
| 81 | PUBLIC HEALTH SERVICES |
| 82 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with Stone aggregate 40mm guage and 100mm sand filling using mechanical mixer for mixing of material |
| 83 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shadecomplete. |
| 84 | Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring or laid with cement based high polymer modified quick set tile adhesive (water based) of approved make IS 15477 marked using 5 Kg adhesive per Sqm of tile area in average 3mm thickness over existing floor, including pointing the joints with white cement and matching pigments etc., complete |
| 85 | Screed of 50mm thick cement concrete 1:8:16 to with aggregate be laid below the topping using mechanical mixer for mixing of material |
| 86 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:2 (1 cement : 2 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete. |
| 87 | For pipes 100 to 250 mm Diametre |
| 88 | Disilting of manhole including all safety measures, cost of container T & P and disposal of silt upto 5km complete in all respects. |
| 89 | Depth upto 3 m. |
| 90 | De-Silting and Cleaning of Sewer lines using Super Suction machine and taking out of debris/silt etc. inclidng safe disposal of silt with in municipals limit as directed by EIC. |
| 91 | 8\\" i/d Sewer Line |
| 92 | Plugging sullage sewer line 8\\"/10\\" with the help of sand filled bags including shuttering at the mouth of sewer in manhole and removing the same i.e. Sand filled bags & Shuttering material from manhole complete in all respects |
| 93 | Pumping of sullage water from main out fall sewer for repair and plugging with sludge pump 800 LPM capacity. |
| 94 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. |
| 95 | 11.43 cm thickness of walls |
| 96 | 22.86 cm thickness of walls |
| 97 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. |
| 98 | Single Socket Type B |
| 99 | 110mm o/d SWR UPVC pipe lines laid complete |
| 100 | 90mm o/d SWR UPVC pipe lines laid complete |
| 101 | Cement concrete 1:2:4 |
| 102 | With stone ballast or shingle |
| 103 | mixing by manual means |
| 104 | Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge ) |
| 105 | 110mm o/d |
| 106 | 90mm o/d |
| 107 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. |
| 108 | 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm |
| 109 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with coats of black bitumastic paint conforming to I.S.I complete as per standard design. |
| 110 | 450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal |
| 111 | Providing, laying, jointing, fixing and testing ISI Marked G.I. Pipe (as per IS 1239) B-Class Premium make such as (Jindal Hisar) including cost of specials (such as tees, bends, sockets, elbows etc.), painting with anti corrosive bitumastic paint, testing, cutting, threading Inside building complete. |
| 112 | 15 mm i/d |
| 113 | 20 mm i/d |
| 114 | 25 mm i/d |
| 115 | Providing, fixing and jointing G.I Union Couplings (of approved make with the approval of EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. |
| 116 | 15 mm i/d G.I. Union |
| 117 | 20 mm i/d G.I. Union |
| 118 | 25 mm i/d G.I. Union |
| 119 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition. |
| 120 | Size 75 mm x 75 mm |
| 121 | Size 150 mm x 150 mm |
| 122 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 123 | Extra for providing and fixing 10 litres capacity Chinaware low level flushing cistern with PVC internal fitting, instead of 10 litres capacity PVC flushing cistern. |
| 124 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. |
| 125 | Size 550 mm x 400 mm x 815 mm |
| 126 | Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect. |
| 127 | Providing and fixing jet spray with 2'-6\\" long PVC pipe. |
| 128 | With C.P. Brass nut |
| 129 | Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 130 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge) complete in all respect. |
| 131 | C.P.brass 15mm Concealed stop cock with flange. |
| 132 | C.P.brass 15mm Angle valve without flange |
| 133 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 134 | PVC tube connection of size 15 mm x 450 mm with C.P. Brass nut |
| 135 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. |
| 136 | C.P. brass Bib cock long nose/ long body foam flow without flange |
| 137 | Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects. |
| 138 | Providing and fixing PVC Floor Trap of size 3\\" including Cement Concrete block 1:2:4 of size 0.45x0.45x0.30 including cost of material and labour complete in all respect. |
| 139 | Providing and fixing in position C.P. Brass Auto close Pillar Cock of approved make (to the approval of Engineer-in-charge) (optional) |
| 140 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. |
| 141 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) |
| 142 | Size 600mmx450mm |
| 143 | Providing and fixing in position paper holders of approved make (to the approval of Engineer-in-charge ) fixed in to wall with C.P brass screws complete in all respect. |
| 144 | C.P. brass toilet paper holder |
| 145 | Providing and fixing in position towel rails /ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. |
| 146 | C.P brass towel ring |
| 147 | Providing and fixing in position C.P.brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
| 148 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge)with various fixtures complete in all respect. |
| 149 | C.P. Brass extension piece, 25mm long to 50mm long |
| 150 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. |
| 151 | Making RCC slab of size 6'-0\\" x 2'-0\\" including cost of material, centering and shuttering, labour, chasing in wall and all other works contingent thereto. |
| 152 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 153 | Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.) |
| 154 | Providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 155 | Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect. |
| 156 | Sink with drain board overall size 1070x464mm bowl size 430x355x200mm and waste coupling |
| 157 | Providing & fixing in postion C.P. brass Sink Cock swinging casted spout (table mounted) of approved make (to the approval of Engineerin- charge) complete in all respect. |
| 158 | Making connection with the existing G.I. branch main up to 40mm size pipe including cutting of existing pipe line, threading of pipe lines from both ends and fixing of G.I Tee etc. in the pipe line (including cost of G.I Tee) complete in all respects. |
| 159 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. |
| 160 | Triple Layer Tanks |
| 161 | Construction of Brick Masonary Platform For Placing Water Storage Tank Of 1000 Litres Capacity Complete In All Respects. |
| 162 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. |
| 163 | G.I. tank nipple 25mm i/d |
| 164 | Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete. |
| 165 | 20mm i/d Brass Ball valves |
| 166 | 25mm i/d Brass Ball valves |
| 167 | Providing and fixing in position automatic brass Ball Cock in tanks. |
| 168 | Brass Ball Cock with rod and Plastic Ball |
| 169 | 20mm i/d |
| 170 | 25mm i/d |
| 171 | Providing and fixing in position SWR UPVC specials for soil waste vent or anti syphonage pipes as per as per IS - 14735 of approved make (to the approval of Engineer-in-charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. |
| 172 | For 110 mm o/d pipes |
| 173 | Single Tee With Door Changed) |
| 174 | Single Tee |
| 175 | Elbow 90 Degree (All side socketed) |
| 176 | Coupler |
| 177 | Vent Cowls |
| 178 | P Trap/Floor Trap 110mm x 110mm |
| 179 | P Trap/Floor Trap 110mm x 75mm |
| 180 | Nahani trap without jali 110mmx90mm |
| 181 | For 90 mm o/d pipes |
| 182 | Single Tee With Door (Description |
| 183 | Single Tee |
| 184 | Coupler |
| 185 | Elbow 90 degree (all side socket) |
| 186 | Vent Cowls |
| 187 | Providing & fixing in position Water Dispenser Top Loading (with refrigration capacity 15 ltr) of approved make (to the approval of Engineerin- charge ) dispensing hot/cold/ambient water including cost of two no. 20 ltrs packaged drinking water bottles and carriage complete in all respect. |
| 188 | Providing and fixing RCC manhole covers only 455 x 610 mm rectangular RCC manhole cover only as per ISI with medium duty |
| 189 | Repair of existing toilet fixtures and fittings , complete job for unforseen expenditure (such repair of floor tiles , fixtures ,accessories, Deep cleaing of floor and fixtures etc.). Complete job |
| 190 | Providing and fixing of FIRE EXTINGUISHER,CO2typeasper IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect. |
| 191 | 2kg capacity |
| 192 | Providing & fixing in positionWater Cooler without Stablizer of approvedmake (to the approval of Engineer-in-charge ) including carriage complete in all respect |
| 193 | Water Cooler Full Steel Body40/80 ltr Capacity without Stablize |
| 194 | Providing & fixing in positionWater Geyser of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect |
| 195 | Providing & fixing in positionWater filter of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect |
| 196 | Providing and installing O-General / Carrier / Mitsubishi /Hitachi make with EER>3.5 Fixed Speed Model Split Type (Cooling only) with installation kit i.e. Copper Pipe) or any other equivalent make Air Conditioner of 1.5 Ton capacity Durawhite PRO+ Cx complete in all respect.(R32) |
| 197 | Providing and installing O-General / Carrier / Mitsubishi /Hitachi make with EER>3.5 Fixed Speed Model Split Type (Cooling only) with installation kit i.e. Copper Pipe) or any other equivalent make Air Conditioner of 2.0 Ton capacity Indus Cx complete in all respect.(R32) |
| 198 | Providing and fixing Plug Top for fixing with stabilizer complete in all respect. |
| 199 | Providing and installing Automatic Voltage Stabilizer copper winding and having suitable range for input and output of 4 KVA capacity of reputed make along with Ampere Meter, Volt Meter & 3 core wire of 1½ metre length complete in all respect make V-Guard, Liv Guard, Luminous and any other equivalent make. |
| 200 | Providing and fixing refrigerant copper pipe for Split type Air Conditioner including insulation complete suitable for 1.5 TR Cap Air Conditioner make Total Line or any other equivalent make. |
| 201 | Providing and fixing 15 mm i/d PVC drain pipe with specials for Split type Air Conditioner complete in all respects of approved make. |
| 202 | Providing and fixing PVC 70/76, 3 Core Electrical Wire for Split type Air Conditioner complete in all respects make Finolex, Havels or any other equivelant make. |
| 203 | Providing and fixing PVC 4 Core Power Cable for Split type Air Conditioner of make Finolex/Havels or any other equivelant make complete in all respects. |
| 204 | Cutting upto 23cm through stone masonry or B.B. in cement wall for laying Copper Pipe, Electrical Wire and Drain Pipe of Split tyoe Air Conditioners 1.5 / 2.0 Ton capacity and making good the same with Cement / Plaster of Paris (POP) to its original condition complete in all respect(Through Wall 22.86 Cm thick) |
| 205 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition. |
| 206 | Size 75 mm x 75 mm |
| 207 | Providing and fixing powder coated angle iron stand heavy duty including grouting for out door unit complete in all respects. |
| 208 | ELECTRICAL SERVICES |
| 209 | Providing Internal Electrical Installations: REPLACEMENT OF WIRES, COVER FRAMES, MODULAR SWITCHES, CONCEALED METAL BOXES AND OTHER ACCESSORIES IN THE EXISTING RECESSED CONDUIT PIPE WIRING SYSTEM (WITH MODULAR TYPE ACCESSORIES) Derived from 34.01:Replacement of PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in existing heavy gauge welded conduit pipe 20 mm/25 mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- (Derived From CSR 34.01)Wiring fan point (With fan box) |
| 210 | Wiring light point |
| 211 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-Wiring fan point (With fan box) |
| 212 | Wiring light point |
| 213 | Wiring call-bell point |
| 214 | Wiring 6Amp. wall socket point |
| 215 | Wiring 6Amp. Plug control comprising wall socket point |
| 216 | Wiring 16/20Amp. power plug control point |
| 217 | RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories). |
| 218 | RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-Wiring Networking socket point RJ45 (one module) |
| 219 | RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. |
| 220 | SUPPLY AND ERECTION OF WIRING ACCESSORIES:Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:-Ceiling Rose (Flush Piano type) |
| 221 | Call Bell 220/230 volts AC Ding Dong |
| 222 | COPPER WIRES & CONDUIT PIPE:PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1sq.mm (Un-sheathed) |
| 223 | Overall size 1.5sq.mm (Un-sheathed) |
| 224 | Overall size 2.5sq.mm (Un-sheathed) |
| 225 | Overall size 4sq.mm (Un-sheathed) |
| 226 | Overall size 10sq.mm (Un-sheathed) |
| 227 | COPPER CONDUCTOR CABLES FOR SPECIAL ELECTRICAL SERVICES:Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-CAT 6 LAN cable |
| 228 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 229 | Heavy gauge PVC conduit pipe 40mm dia. (ISI marked) Flushed |
| 230 | Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:-PVC Flexible Pipe 25mm dia. |
| 231 | HEAVY GUAGE WELDED CONDUIT PIPES:Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:-Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan. |
| 232 | G.I. EARTHING :- Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling).Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 8Metre in length) |
| 233 | G.I. EARTHING WIRE/ ROPE (AS ADDITIONAL LENGTH):Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (Flushed in wall and floor) with sockets, elbows and Steel hooks including the cost of cutting and filling up of chases (with finishing the surface):-Additional length G.I. wire 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe (Flushed) |
| 234 | Copper EarthingEarthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long |
| 235 | Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:-Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed) |
| 236 | MCB'S & MCB DISTRIBUTION BOARDS:MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 237 | MCB Double Pole 32 amp. (10kA, Curve-C) |
| 238 | MCB Double Pole 40amp. (10kA, Curve-C) |
| 239 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's:Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-SP&N Double Door Distribution Board 12 way each |
| 240 | SP&N Double Door Distribution Board 4 way each |
| 241 | XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:-Overall size 6sq.mm (2Core) Un-armoured (On-Surface) |
| 242 | LT CABLESXLPE INSULATED UN-ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-Overall size 10sq.mm (4Core) Un-armoured (Loose) |
| 243 | Overall size 6sq.mm (2Core) Un-armoured (Loose) |
| 244 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-Double walled corrugated (DWC) HDPE pipe 63/51 mm (outer/ inner dia.) |
| 245 | SHEET METAL IRON CLAD CHANGEOVER SWITCHES:Supply and erection of sheet metal Iron Clad Changeover Switch on existing surface with G.I. bolts & nuts/rag bolts and nuts etc., according to the size of holes in the body of the switch including connections with suitable size of thimbles and bonding to the existing earth as per PWD General Specifications:-ICDP Changeover Switch 63amp., 415volts |
| 246 | GI PIPE POLES & BRACKETS:SINGLE ARM BRACKETS FOR GI PIPE POLE:Supply and erection of G.I. Pipe 40mm dia. (A-class) Single arm bracket of suitable length give a total overhang at a tentative angle of 100/105º, the bracket should be fixed on the top of the GI pipe pole having top outer dia. 80mm/100mm with GI reducer of suitable size with two coats of an approved aluminium paint complete in all respect as approved by the Engineer-in-charge at site:-Single Arm Bracket 1 metre Long with G.I. Reducer 80mm x 40mm |
| 247 | LED'S FIXTURES & FANS:Supply and erection of LED batten 20watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary |
| 248 | Supply and erection of LED batten 40watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary |
| 249 | Supply and erection of Recessed mounted 36watt LED 2x2 panel (including constant LED driver) with CRCA sheet having with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers and hanging GI wire with top roof complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary. |
| 250 | Supply and erection of Recessed mounted 18watt LED Downlighter(including LED driver) with Pressure Die Cast with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary. |
| 251 | Supply and erection of LED Street Light 45 watt (including LED driver) with pressure die cast aluminium housing with control gear ( IP 66 protection),THD< 10%, CRI minimum 70, High power LED with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, efficacy of LED fixture minimum 120 lumens per watt, complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to CM Punjab vide letter No. AT-2021/GL 1410-1422 Dated 06/05/2021 |
| 252 | Supply and erection of Ceiling Fans 1200 mm Sweep (48\\") 3-Star fan without fan regulator copper wound including flexible wire & petty material etc.complete in all respects as appd. and desired by the Engineer in-charge at site. |
| 253 | Supply and erection of Ventile Air Fan 230/250mm with aluminium louver shutter longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. The fan should conform to Technical Specifications attached. |
| 254 | Supply and erection of Wall Fan Size 400MM complete in all respect as approved and desired by the Engineer in-charges at site. The fan should conform to Technical Specifications attached. |
| 255 | Supply and erection of sine wave Inverter copper wound 1100 VA with Tubular Battery 200AH with Trolley stand complete in all respects as approved and desired by the Engineer in-charge at site. |
| 256 | Providing -2 Way Phone, Patient Token System,Local Area Networking :Supply Installation Testing and Commissioning of 10 port 10/100 PoE switch, 8*10/100 PoE port + 2 10/100 uplink, power budget 120W, IEEE 802.3af/at extended range 250 mtr complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 257 | Supply, installation, testing & commissioning of 1 KVA UPS with Input power factor - 0.99, Output power factor - 0.8, OVCD inbuilt , DC V 24v, Efficiency : Above 90%. .complete in all respects as approved and desired by the Engineer-in-charge at site |
| 258 | S/I/T/C of intercom facility 1+1 Basic Plan Phone Ringer volume control switch Tone/ Pulse Switchable Redial Mute Flash Pause Intercom facility Call T, Holding the line / Music on Hold during call transfer Line use LED Indication, Secrecy during conversation between both phones, including connecting cables complete in all respect as approved and desired by the Engineer in-charges at site |
| 259 | S/I/T/C of Token Calling Display System having screen size 4 inches, Voice calling/ Bell System, complete key pad Etc, calling display up to 60 meter cable (5 meter length included), serial communication design, Text Color Red Display Shape Rectangle,Power 5 W,Sound Type Mono Display Technology 7 Segment Voltage 220-240 V AC Suitable for Clinic, Hospital,Cash counter etc, Warranty 1 Year,220 VAC Operating Voltage Character Capacity 3 Character, Power Consumption,Rectangular Metal body ,complete in all respect as approved and desired by the Engineer in-charges at site |
| 260 | Supply and erection of Wall Mounted 6U Rack with power point and fan. complete in all respect as approved and desired by the Engineer in-charges at site |
| 261 | Supply and erection of PVC Telephone wire 2 Pair 0.50mm. complete in all respects as approved and desired by the Engineer-in-charge at site. Total A+B+C Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail