| 1 | Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with 3 nos. blades,30 cm long down rod, 2 nos, canopies, shackle kit, safety rope,copper winding, power factor not less than 0.9, Service Value (CMM/W)minimum 6.85, Air delivery minimum 215 CMM,350 PRM (tolerance as per IS:374-2019),THD less than 10%, remote for speed control and all remaining accessories including safety pin, nut bolts, washers temperature rise-75 degree C(max), insulation resistance more than 2 mega ohm, suitable for 230 V, 50Hz, single phase AC supply, earthing etc. complete as required. |
| 2 | Supply, Installation, testig and commissioning of following capacity geyser ISI marked having S.S. tank and outer ABS body BEE 5 star rating, 8.0 bar pressure,Vertical type i/c plug top complete with connection, industrial top, inlet and outlet water piping complete etc.reqired. |
| 3 | 25 liters |
| 4 | Supply, Installation, testig and commissioning of 600 x 600mm LED panel (Nomial dimension) 36 watts Surface/ Recess Type Metallic CRCA Powder coated Housing Hing efficiency Diffuser cover having minimum lumen efficacy as 100 lumens/ watt complete with accessories as required. |
| 5 | Round shaped recessed LED Down light 12/15 watt having minimum lumen efficacy as 100 lumens/watt complete with accessories as required. |
| 6 | SITC of 250 mm sweep Ventilating fan with plastic body and louvers i/c connection with 2x1.5 sqmm cu. Conductor FR PVC cable etc as required at site. (M/S HAVELLS/Crompton Greaves/Usha/ khaitan/Bajaj/ Orient). |
| 7 | Extruded Aluminium 2 ft LED Batton 10 watt having minimum lumen efficacy as 100 lumens/watt with accessories as required. |
| 8 | Extruded Aluminium 4 ft LED Batton 20 watt having minimum lumen efficacy as 100 lumens/watt with accessories as required. |
| 9 | Supply,Installation,testing and commissioning 300mm x 300mm LED panel (Nominal dimension) 24 watts Surface/Recess Type CRCA powder coated housing hing efficiency diffuser cover having minimum lumen efficacy as 100 lumens/watt complete with accessories as required. |
| 10 | LED Street Light/Flood Light luminaire 50 w with epoxy poder caated pressure die cast aluminium housing & acrylic/Polycarbonate cover with gi Bracket. |
| 11 | Supply, instaletion ,testing and commissioning of following capacity geyser ISI marked having S.S.Tank and outer ABS body BEE 5 star rating ,Vertical type i/c plug top complete with connection ,industrial top ,inlet and outer water piping complete etc. as required. 3 Litres |
| 12 | Supplying, installation, testing & commissioning of following Indoor type, compartmentalized and sectionalized cubicle panel of size 1.85 m x 1.875m x 600mm deep, fabricated from cold rolled CRCA sheet steel fo 2 mm thick, having vibration free structure chemically treated surface with seven tank process before painting, epoxy powder coated after two coats of anti-rust primer, making earth connections by providing Aluminium earth strip of minimum size 25 x 5 mm thick all along horizontal run of the panel suitable for operation on 3 phase 415 V 50 HZ AC supply i/c 400 Amp TPN Aluminium Busbar suitable for with standing fault level of 31 MVA for 1 Sec with heat shrinkable coulred sleeves i/c SMC/DMC bus bar supports at required interval.s (Current density shall be maximum 1.3 A/sqmm), providing and fixing the following switchgear to be mounted thereon complete with gaskets, interconnections and earthing with suitable size PVC insulated FRLS copper wire. The panel shall be dust free, vermin proof and totally enclosed with Degree of protection of IP 42 as per IS 2147, with suitable cable/busbar alleys and shall be mounted on MS chnnels of size not less than 50 X 50 X 6 mm iron frame on floor etc as per specification complete as required. Gland plates should be minimum 3 mm thick at top and bottom LED cluster indication lamp shall be provided on each compartment (incomer/outgoing/bus coupler) for ON, OFF and TRIP i.e. Providing and fixing following accessories in above cubicle panel board including drilling holes in cubicle panel, making connection, etc. as required. |
| 13 | INCOMING |
| 14 | 250A 4P On Load Manual Changeover Switch-Disconnector with 2 C/O, Frame-3, Type: CO3-250, Open Execution |
| 15 | 250 A 3P 25KA MCCB TM Release, Type: DN1-250C, 415 V AC, 50 Hz |
| 16 | Spreader Terminals - 3 Pole (Set of 6) for DN1, DN2-250 MCCB |
| 17 | Red Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC |
| 18 | Yellow Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC |
| 19 | Blue Gen Next Pro LED Indicator 22.5mm, Voltage: 240V AC |
| 20 | VAF + PF Meter, 3Ph, Parameters: VLL, VLN, A,F,PF, On Hrs, RPM, Apeak, Acc. CL: 1, Aux Supply: 80-300V AC/DC, Size: 96X96, Model: 4110 |
| 21 | 250/5A 15VA Resin Cast Acc. Cl: 1 Rectangular Type Current Transformer, Size: 55x20mm |
| 22 | 6A 1P 10kA, C-Curve MCB |
| 23 | 4 Sq.mm Disconnecting Terminal (Std. Color), Type: KLTD M4NV |
| 24 | End Plate (Std. Color), Type: KPLD4 for Terminal: KLTDM4 |
| 25 | Slide Clamps with fixing Screws, Type: SCUN (POLYAMIDE 6.6) |
| 26 | 32A Neutral Link, Channel Mounting, Color: Black/Grey |
| 27 | OUTGOING |
| 28 | 160A 3P 25kA MCCB TM Release, Type: DN1-250C, 415V AC, 50Hz |
| 29 | Spreader Terminals- 3 Pole (Set of 6) for DN1, DN2-250 MCCB |
| 30 | Red Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC |
| 31 | Yellow Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC |
| 32 | Blue Gen Next Pro LED Indicator 22.5mm, Voltage: 240V AC |
| 33 | VAF + PF Meter, 3Ph, Parameters: VLL, VLN, A,F,PF, On Hrs, RPM, Apeak, Acc. CL: 1, Aux Supply: 80-300V AC/DC, Size: 96X96, Model: 4110 |
| 34 | 160/5A 15VA Resin Cast Acc. Cl: 1 Ring Type Current Transformer, ID: 30mm |
| 35 | 6A 1P 10kA, C-Curve MCB |
| 36 | 4 Sq.mm Disconnecting Terminal (Std. Color), Type: KLTD M4NV |
| 37 | End Plate (Std. Color), Type: KPLD4 for Terminal: KLTDM4 |
| 38 | Side Clamps with Fixing Screws, Type: SCUN (POLYAMIDE 6.6) |
| 39 | 32A Neutral Link, Channel Mounting, Color: Black/Grey |
| 40 | O/G'S MCCB 160A 3P |
| 41 | 160A 3P 25kA MCCB TM Release, Type: DN1-250C, 415V AC, 50Hz |
| 42 | Spreader Terminals-3 Pole (Set of 6) for DN1, DN2 -250 MCCB |
| 43 | O/G's MCCB 100A 3P |
| 44 | 100A 3P 25kA MCCB TM Release, Type: DN0-100C, 415V AC, 50Hz |
| 45 | Spreaser Terminals - 3 Pole (Set of 6) for DN0-100MCCB |
| 46 | STREET LIGHT MCB 63A 4P |
| 47 | 63A 4P 10kA, C-Curve MCB |
| 48 | 20A 2P 10kA, C-Curve MCB |
| 49 | 6A 1P 10kA, C-Curve MCB |
| 50 | Astro Time Switch Mini-2 Mod, 110-240V AC |
| 51 | AC3: 40A AC1: 50A 3P Power Contactor, Coil: 240V AC, Type: MO 40 |
| 52 | Earthing and Lightning Conductor |
| 53 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 54 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 55 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 56 | Providing and fixing 25mmx5mm GI strip on surface or in recess for connections etc as required |
| 57 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 58 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300mm long, G.I. tube, having single prong at top, with 85mmdia 6mm thick G.I. base plate including holes etc. complete as required. |
| 59 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/sweating and soldering etc as required. |
| 60 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 61 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 62 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 63 | Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. Please Enable Macros to View BoQ information |