Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 0.00 to 1.50 m.) By Manual Means--Specification No--Bd.A.1/Page No.259 -SSR 2022-23 I No. 21.02 i) Warehouse Building = 113.40 Cum. ii) Machinery Shed = 70.85 Cum. |
| 2 | Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Manual Means-Specification No-Bd.A.1/Page No.259 -SSR 2022-23 I No.21.03 i) Warehouse Building = 56.70 Cum. ii) Machinery Shed = 35.42 Cum. |
| 3 | Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete.-Specification No-As directed by Engineer in charge. -SSR 2022-23 I No.21.40 i) Warehouse Building = 103.355 Cum. ii) Machinery Shed = 64.669 Cum. |
| 4 | Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) .--Specification No--Bd. E. 1/Page No. 287 -SSR 2022-23 I No.24.01 i) Warehouse Building = 68.90 Cum. ii) Machinery Shed = 43.113 Cum. |
| 5 | Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)--Specification No--Bd.F.3 Page One Number 298 and B.7, Page One Number38 -SSR 2022-23 I No25.11 i) Warehouse Building = 40.032 Cum. ii) Machinery Shed = 26.568 Cum. |
| 6 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)--Specification No--Bd.F.5 Page One Number 300 and B.7,Page.One Number 38 -SSR 2022-23 I No25.31 i) Warehouse Building = 28.082 Cum. ii) Machinery Shed = 10.860 Cum. |
| 7 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)--Specification No--Bd.F.9 Page One Number 303 and B.7, Page One Number38 -SSR 2022-23 I No.26.50 i) Warehouse Building = 28.39 Cum. ii) Machinery Shed = 18.16 Cum. |
| 8 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) --Specification No--Bd.F.8 Page No. 302 and B.7, Page No.38-SSR 2022-23 I No.25.70 i) Warehouse Building = 3.456 Cum. ii) Machinery Shed = 0.963 Cum. |
| 9 | Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) --Specification No--Bd.F.8 Page No. 302 and B.7, Page No.38 -SSR 2022-23 I No.26.05 i) Warehouse Building = 3.504 Cum. ii) Machinery Shed = 2.849 Cum |
| 10 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.--Specification No--Bd.F.17, Page One Number 306 -SSR 2022-23 I No.26.33 i) Warehouse Building = 10.256 Mt. ii) Machinery Shed = 5.788 Mt. |
| 11 | Filling in plinth and floors with approved excavated material in 15cm. to 20cm. layers including watering and compacting etc. complete.--Specification No--Bd.A.10 Page No. 262-SSR 2022-23 I No.21.36 i) Warehouse Building = 62.462 Cum. ii) Machinery Shed = 0.00 Cum. |
| 12 | Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete.--Specification No--Bd.A.11 Page No. 263-SSR 2022-23 I No.21.37 i) Warehouse Building = 713.405 Cum. ii) Machinery Shed = 518.125 Cum. |
| 13 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete.--Specification No--Bd.G. 1 Page No. 313-SSR 2022-23 I No.27.01 i) Warehouse Building = 12.577 Cum. ii) Machinery Shed = 11.288 Cum. |
| 14 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete--Specification No--Bd.G.5 Page One Number 315 -SSR 2022-23 I No.27.05 i) Warehouse Building = 34.914 Cum. ii) Machinery Shed = 45.885 Cum. |
| 15 | Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. : Bd.E. 3/Page No. 288/I.S. 456 (2000) -SSR 2022-23 I No.24.16 i) Warehouse Building = 2.10 Cum. ii) Machinery Shed = 1.71 Cum. |
| 16 | Providing and fixing mild steel grill work for windows, ventilators, etc. 15 kg/sqm as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete.Spec. No. : Bd.U.1 Page No. 537 -SSR 2022-23 I No.24.16 i) Warehouse Building = 19.44 Sqm. ii) Machinery Shed = 16.20 Sqm. |
| 17 | Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 mm at weight 0.547 kg/Rmt. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 kg/Rmt. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. And handle section 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. and top section 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With powder coating with box Spec. No. : Bd.U.1 Page No. 537 -SSR 2022-23 I No.24.16 i) Warehouse Building = 19.44 Sqm. ii) Machinery Shed = 16.20 Sqm. |
| 18 | Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.--Specification No--Bd. L.2 Page No. 368 -SSR 2022-23 I No.32.04 i) Warehouse Building = 245.40 Sqm. ii) Machinery Shed = 214.98 Sqm. |
| 19 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.--Specification No--Bd.L.7 Page One Number 369-SSR 2022-23 I No.32.11 i) Warehouse Building = 371.06 Sqm. ii) Machinery Shed = 318.18 Sqm. |
| 20 | Providing and laying in situ cement concrete M20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete.--Specification No--As directed by Engineer in charge-SSR 2022-23 I No.33.30 i) Warehouse Building = 594.50 Sqm. ii) Machinery Shed = 372.09 Sqm. |
| 21 | Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (Without mechanical gear)--Specification No--BD-T-55 Page One Number 510-SSR 2022-23 I No.39.25 i) Warehouse Building = 30.00 Sqm. ii) Machinery Shed = 7.50 Sqm. |
| 22 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per One Square Metre of surface area covering ten years guarantee on bond paper. Specification No--As directed by Engineer in charge.-SSR 2022-23 I No.21.22 i) Warehouse Building = 594.50 Sqm. ii) Machinery Shed = 372.09 Sqm. |
| 23 | Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete..--Specification No--Bd. L.10, Page One Number370-SSR 2022-23 I No.32.15 i) Warehouse Building = 245.40 Sqm. ii) Machinery Shed = 214.98 Sqm. |
| 24 | Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.Spec.No.: As directed by Engineer in charge.SSR 2022-23 I No.35.21 i) Warehouse Building = 245.40 Sqm. ii) Machinery Shed = 214.98 Sqm. |
| 25 | Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete.Spec.No.: As directed by Engineer in charge.SSR 2022-23 I No.35.25 i) Warehouse Building = 616.46 Sqm. ii) Machinery Shed = 533.16 Sqm. |
| 26 | Management Strategies and implementation plan (MSIP) to manage the Environmental Social Health and safety (ESHS) risks and ESHS Code of Conduct |
| 27 | ABC Types Fires estinguishers are effective for all types of fire like Class A,B & C types of Fire as well as electrical fire and also ABC powder types (Stored Pressure Fire Estinguishers multipurpose uses & ISI ISO & CE Certified product and multipurpose uses ABC Type Fire Estinguishers 6Kg. with 5 year warranty. |
| 28 | Supplying, fabricating, erecting and fixing in position of steel structures at all elevations using fusion welding quality steel E-350 (Fe490) conforming to IS:2062 - 2006. Rate shall include cost of cutting, welding, splice plates and packing plates, transporting, straightening, cleaning, fabricating and erecting in position welded/bolted Structural steelwork in columns, beams, trusses, purlins, platforms, ladders, monorails, staircases ,supports, strengthening of steel members etc. at site to line and level, supply of approved bolts/nuts/washers etc. complete as per drawings including painting as per G4/G5/G6 before erection and all materials and labour charges etc., complete and including Sand blasting & painted with 1 coats of enamel paint (Berger EPILUX SG – HHI 664002) of 35-50 micron each coat with air less spray gun over a coat of zinc chromate primer - 35-50 micron etc., complete as shown in drawings, as per specifications and as directed by the Engineer-in-Charge / Construction Manager. (The rate quoted shall include cost of bolts, nuts, washers, welding and electrodes required for the complete work). (Mecanical SSR 2022-23) i) Warehouse Building = 25.30 Mt. ii) Machinery Shed = 11.50 Mt. |
| 29 | Supplying, fabricating and erecting of Cold Formed Light Gauge structural steel members conforming to IS:801/ IS:811 hot-dip galvanised to IS:4759 - 96 including cutting, welding or bolting, splice plates and packing plates, transporting, straightening, cleaning, fabricating and erecting in position. (Mecanical SSR 2022-23) i) Warehouse Building = 5.00 Mt. ii) Machinery Shed = 2.50 Mt. |
| 30 | Supply & Fixing of PPGI sheets of 0.5 mm thick as shown in drawing or as directed by engineer incharge with all necessary accessories.(Essar) Make) (Mecanical SSR 2022-23) i) Warehouse Building = 15.89 Mt. ii) Machinery Shed = 7.98 Mt. |
| 31 | Supply & Fixing of 0.5 mm thk PPGL roof accessories as per drawing or as directed by engineer in charge. (Mecanical SSR 2022-23) i) Warehouse Building = 104.06 Rmt. ii) Machinery Shed = 89.90 Rmt. |
| 32 | Supplying, fabricating and erecting in position PPGI Eaves Gutter of required size with stop ends,all fixing accessories, drop ends, etc., at all elevations levels & heights including aligning, leveling, providing and fixing bolts, nuts, washers etc., conforming to latest specification including straightening, cutting, welding, bending to shape, bolting etc., complete and as directed as per engineer incharge (Mecanical SSR 2022-23) i) Warehouse Building = 56.12 Rmt. ii) Machinery Shed = 31.00 Rmt. |
| 33 | Providing and fixing of the rain water down take pipes of PPGI, the sectional area of rain water down take pipes provided shall be generally at the rate of 1 square cm per 70 to 80 square decimetre of roof area drained. No spout shall be less than 80 mm in diameter. The spacing of spouts shall be arranged to suit the position of openings in the wall including necessary accessories for fixing the pipe and including all materials and labour charges etc., complete as shown in drawings, as per specifications and as directed by the Engineer-in-Charge (Mecanical SSR 2022-23) i) Warehouse Building = 36.00 Rmt. ii) Machinery Shed = 24.00 Rmt. |
| 34 | Supply & Fixing of 2mm thk polycarbonate sheets as per drawing & as directed by engineer in-charge. (Mecanical SSR 2022-23) i) Warehouse Building = 21.60 Sqm. ii) Machinery Shed = 7.20 Sqm. |
| 35 | Supply & Fixing of turbo ventilator with 610 mm throat, having base ring & top plate in stainless steel of 0.8 mm thick, rotated using twin bearings of SKF - 600122 & 600322 permanently lubricated & sealed. Fixed in FRP base plate of 2mm thk clear 1.020 mtr wide & 1.7 mtr long. (Mecanical SSR 2022-23) i) Warehouse Building = 6.00 No. ii) Machinery Shed = 6.00 No. |
| 36 | Clearing grass and removal of rubbish up to a distance of 50 metres outside the periphery of the area . Specification No--MORTH 301-SSR 2022-23 I No.2.11 i) Warehouse Building = 996.72 Sqm. |
| 37 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mm Aggregate). Specification No--MORTH 309-SSR 2022-23 I No.2.18 i) Warehouse Building = 112.13 Cum. ii) Machinery Shed = 0.00 No. |
| 38 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means - Grading II (Using Screening Type B (11.2 mm) Aggregate). Specification No--MORTH 305-SSR 2022-23 I No.2.24 i) Warehouse Building = 52.33 Cum. ii) Machinery Shed = 0.00 No. |
| 39 | Providing and constructing 75 mm. thick Modified Penetration Macadam (MPM) road surface including all materials, preparing the existing road surface, spreading 40 mm. stone metal layers 30% crusher broken metal + 70% Hand broken (by breaking rubble obtained by blasting) heating and spraying the bitumen of specified grade @ 2 Kg/sqm, spreading 12 mm.size chips compacting with three wheel static roller having weight 8 to 10 MT. to achive the desired degree of compaction as per Technical Specification Clause 506 etc. complete. Including picking of existing WBM surface. (VG-30 bulk bitumen rates are considered to arrive at rates) Specification No--MORTH 305-SSR 2022-23 I No.2.31 i) Warehouse Building = 622.95 Sqm. |
| 40 | Open Graded Premix Surfacing- Providing and Laying OGC 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates premixed with bituminous binder transported to site with VTS , laid over a previously prepared surface, finished to the required grade, level, alignment, and rolling to achieve the desired compaction but excluding prime / tack and Seal coat. For Bitumen of specified grade--USING drum mix type hot mix plant with SCADA, Paver and Vibratory roller ( Over MPM Surface) (VG-30 bulk bitumen rates are considered to arrive at rates). Specification No--As directed by Engineer-in-charge-SSR 2022-23 I No.50.56 i) Warehouse Building = 622.95 Sqm. |
| 41 | 9 MM SEAL COAT: Providing and laying of Type A 9mm premix seal coat with HMP of apropriate capacity crushed stone chiping 6.7 mm size and penetration bitumen of specified grade @ 1.2kg/Sq.m, preparing existing road surface by mechanical means, spreading chips and rolling, by static roller having weight 8 to 10 MT. etc. complete.(VG-30 bulk bitumen rates are considered to arrive at rates) Specification No--As directed by Engineer-in-charge-SSR 2022-23 I No.50.57 i) Warehouse Building = 622.95 Sqm. |
| 42 | Supplying hard murum/ kankar at the road site, including conveying and stacking complete.. Specification No--As directed by Engineer-in-charge-SSR 2022-23 I No.2.29a i) Warehouse Building = 254.16 Cum. |
| 43 | Spreading hard murum/ soft murrum/ gravel or kankar for side width complete. Specification No--As directed by Engineer-in-charge-SSR 2022-23 I No.2.29b i) Warehouse Building = 254.16 Cum. |
| 44 | Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etc. complete. .. Specification No--As directed by Engineer-in-charge-SSR 2022-23 I No.50.58 i) Warehouse Building = 1694.42 Cum. |
| 45 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Specification No--As directed by Engineer-in-charge-SSR 2022-23 I No.2.30 i) Warehouse Building = 150.00 Rmt. ii) Machinery Shed = 250.00 Rmt. |
| 46 | Making trench in soft soil having 0.75 m depth and minimum 0.3 m width for laying provided cables up to voltage level of 1.1kV complete As per specification No. CW-EXN-CTR Spec.No.: As directed by Engineer-in- charge i) Warehouse Building = 9.50 Rmt. ii) Machinery Shed = 6.00 Rmt. |
| 47 | Making trench in Hard murum/Tar road having 0.75 m depth and minimum 0.3mtr width as per IS for laying provided cables up to voltage level 1.1Kv cable complete as per specification No. CW-EXN-CTR -Specification No--As directed by Engineer-in-charge SSR 2022-23 I No.50.59 i) Warehouse Building = 10.00 Rmt. ii) Machinery Shed = 6.00 Rmt. |
| 48 | Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW -Specification No--As directed by Engineer-in-charge SSR 2022-23 I No.50.61 i) Warehouse Building = 160.00 Rmt. ii) Machinery Shed = 200.00 Rmt. |
| 49 | Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 10A, 2 pin plug & earth socket and 10A, 3 pin plug top with 10A single pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron / GI frame.Specification No--As directed by Engineer-in-charge SSR 2022-23 I No.3.37b i) Warehouse Building = 2.00 No.ii) Machinery Shed = 2.00 No. |
| 50 | Point wiring for light/fan/bell in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire with flush type switch and required accessories as per specification No: WG-PW/SW Specification No--As directed by Engineer-in-charge SSR 2022-23 I No.51.139a i) Warehouse Building = 10.00 Point. ii) Machinery Shed = 6.00 Point. |
| 51 | Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22 /E-27 base. Specification No--As directed by Engineer-in-charge SSR 2022-23 I No.4.13 i) Warehouse Building = 6.00 No.ii) Machinery Shed = 5.00 No. |
| 52 | Supplying and erecting integrated LED street light fitting 23 to 25W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 1800 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50,including driver complete with 3 Years warranty as per specification No FGODF/FLS2.Specification No--As directed by Engineer-in-charge SSR 2022-23 I No.11.27 i) Warehouse Building = 15.00 No.ii) Machinery Shed = 5.00 No. |
| 53 | Supplying and erecting Street light bracket made from 40 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC. Spec. No. As directed by Engineer in Charge Specification No--As directed by Engineer-in-charge SSR 2022-23 I No.6.36 i) Warehouse Building = 15.00 No. ii) Machinery Shed = 5.00 No. |
| 54 | SProvidng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no.EA-EP Electrical CSR 2022-23 I No.7-1-7 i) Warehouse Building = 1.00 No. ii) Machinery Shed = 1.00 No. |
| 55 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no.EA-EP Electrical CSR 2022-23 I No.16-1-1 i) Warehouse Building = 1.00 No. ii) Machinery Shed = 2.00 No. |
| 56 | MSupplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB Warehouse Building = 4.00 No. ii) Machinery Shed = 2.00 No. Electrical CSR 2022-23 I No.16-1-2 i) Warehouse Building = 40.00 Rmt. ii) Machinery Shed = 5.00 Rmt. |
| 57 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB Warehouse Building = 4.00 No. ii) Machinery Shed = 2.00 No. Electrical CSR 2022-23 I No.7-1-7 i) Warehouse Building = 100.00 Rmt.ii) Machinery Shed = 40.00 Rmt. |
| 58 | Supplying and erecting GI sheet 1.6 mm (16 SWG) having zinc coating of 350 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. Warehouse Building = 2.00 Sqm. ii) Machinery Shed = 8.00 Sqm. |
| 59 | Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to IS 720:2010 Electrical CSR 2022-23 I No.2-4-2 i) Warehouse Building = 2.00 Sqm.ii) Machinery Shed = 2.40 Sqm. . |
| 60 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 Electrical CSR 2022-23 I No.2-7-3 i) Warehouse Building = 8.00 Rmt. ii) Machinery Shed = 6.00 Rmt. |
| 61 | Supplying & erecting G.I. pipe ‘A’ class 25 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE Electrical CSR 2022-23 I No.9-1-3 i) Warehouse Building = 8.00 Rmt. ii) Machinery Shed = 6.00 Rmt. |
| 62 | Supplying & erecting G.I. pipe ‘A’ class 40 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE Electrical CSR 2022-23 I No.9-1-4 i) Warehouse Building = 6.00 Rmt. ii) Machinery Shed = 6.00 Rmt. |
| 63 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. Electrical CSR 2022-23 I No.5-3-6 i) Warehouse Building = 20.00 Rmt. ii) Machinery Shed = 10.00 Rmt. |
| 64 | Supplying & erecting single compression type brass cable glands for 3 to 4 core 6 sq mm /2 to 4 core 10 sq mm for XLPE armoured cable as per specification No. CB-GL Electrical CSR 2022-23 I No.5-3-2 i) Warehouse Building = 10.00 No. ii) Machinery Shed = 4.00 No. |
| 65 | Supplying and erecting Ceiling rose / Batten holder / Slanting holder /hanging cord switch / hanging bell push / pendant holder bakelite base 6A. erected on filled polypropylene board or polished double wooden block/PVC junction box.. Electrical CSR 2022-23 I No.6-1-6 i) Warehouse Building = 5.00 No. ii) Machinery Shed = 4.00 No. |
| 66 | Point wiring for independent plug in 20 mm metal conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, flush type switch, earthing and required accessories as per specification No: WG-PW/SW Electrical CSR 2022-23 I No.6-1-14 i) Warehouse Building = 12.00 Point. ii) Machinery Shed = 3.00 Point. |
| 67 | Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/CW Electrical CSR 2022-23 I No.5-4-3 i) Warehouse Building = 12.00 Point. ii) Machinery Shed = 6.00 Point. |
| 68 | Supplying & erecting mains with 2x2.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WGMA/BW. Electrical CSR 2022-23 I No.16-5-3 i) Warehouse Building = 150.00 Rmt.ii) Machinery Shed = 200.00 Rmt. |
| 69 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW. Electrical CSR 2022-23 I No.16-5-5 i) Warehouse Building = 150.00 Rmt. ii) Machinery Shed = 200.00 Rmt. |
| 70 | Supplying and erecting modular type D.P. switch 32A with indicator, duly erected on provided plate and box with wiring connections complete. Electrical CSR 2022-23 I No.7-6-10 i) Warehouse Building = 2.00No.ii) Machinery Shed = 2.00 No. |
| 71 | Supplying, erecting and marking double pole isolator only switch version of miniature circuit breaker of 40A with required wiring connections and lugs etc. in provided distribution board..i) Warehouse Building = 4.00 No. ii) Machinery Shed = 2.00 No. |
| 72 | Supplying & erecting 3W, 230V integral type LED Lamp suitable for B-22 / E-27 base..i) Warehouse Building = 6.00 No. ii) Machinery Shed = 3.00 No. |
| 73 | Supplying and erecting IP65 and IK08 rated UV shielded polycarbonate waterproof and dustproof industrial grade LED fitting (4 feet) max. 36W with high transitivity diffuser with system lumens output of min. 4300 lumens,min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50 , IP20 rated, including driver with auto cutoff & auto restart feature at 325V with end caps on PVC Block/wooden board with 3 years warranty..i) Warehouse Building = 5.00 No. ii) Machinery Shed = 1.00 No. |
| 74 | Royalty For Sand Warehouse Building = 134.27 Cum.ii) Machinery Shed = 95.40 Cum. |
| 75 | Royalty For All Other Murum & 80mm Metal Warehouse Building = 816.76 Cum.ii) Machinery Shed = 582.79 Cum. |
| 76 | Material Testing MIX DESIGN M-20 Concrete Concrete Mix Design (With all Tests on basic materials) |
| 77 | CONCRETE CUBE TEST For M-10 (Compressive Strength OF C.C. Cube (Set of 3 cubes)) |
| 78 | CONCRETE CUBE TEST For M-20 (Compressive Strength OF C.C. Cube (Set of 3 cubes)) |
| 79 | BRICK TEST (Water Absorption (Set of 5 Bricks), Compressive Strength( Set of 5 Bricks), Efflorescence) |
| 80 | BASIC TEST OF CEMENT.(Standard Consistancy, Fineness, Specific Gravity, Setting Time ( Initial & Final ), Compressive Strength, Soundness.) |
| 81 | STEEL BAR TESTING (Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress.) |
| 82 | BASIC TEST OF AGGREGATE.(Water Absorption, Specific Gravity,Impact Value, Crushing Value.) |
| 83 | FINE AGGREGATE.(Fineness Modulus ( Sieve Analysis ),Silt & Clay Content) |
| 84 | SOIL / MURUM (Sieve Analysis.) |
| 85 | Liquid limit & plastic Limit. |
| 86 | Compaction Test ( Proctor Density ) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail