| 1 | CONSTRUCTION OF SUMP-CIVIL WORKS |
| 2 | 2.31Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees andsaplings of girth up to 30 cm measured at a height of 1 m above ground level andremoval of rubbish up to a distance of 50 m outside the periphery of the area cleared |
| 3 | 2.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposedearth to be levelled and neatly dressed.All kinds of soil |
| 4 | 2.25Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 5 | 4.1.8Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4coarse sand : 8 graded stone aggregate 40 nominal size) |
| 6 | 5.9.6Centering and shuttering including strutting, etc. and removal of form for:Columns,Pillars, Piers, Abutments, Posts and Struts |
| 7 | 5.9.3Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform |
| 8 | 5.2.2Reinforced cement concrete work in walls (any thickness), including attachedpilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. up tot floor five level excluding cost of centering,shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 gradedstone aggregate 20 mm nominal size) |
| 9 | 5.22A.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo - MechanicallyTreated bars of grade Fe-500D or more |
| 10 | 13.7.212 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1cement : 4 fine sand) |
| 11 | 22.3Providing and laying water proofing treatment to vertical and horizontal surfaces ofdepressed portions of W.C. kitchen and the like consisting of : i) I course of applyingcement slurry @ 4.4 Kg/ sqm mixed with water proofing compound conforming toIS: 2645 in recommended proportions including rounding off junction of vertical andhorizontal surface. ii) II course of 20 mm cement plaster 1:3 ( 1 cement : 3 coarsesand) mixed with water proofing compound in recommended proportion includingrounding off junction of vertical and horizontal surface. iii) III course of applyingblown or residual bitumen applied hot at 1.7 kg per sqm of area. iv) IV course of 400micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wideand pasted to each other with bitumen @ 1.7 Kg/ sqm |
| 12 | CONSTRUCTION OF SUMP-PLUMBING WORKS |
| 13 | 50.18.9.13.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 25 mmdia 10 Kgf/cm2- External work - Exposed on wall |
| 14 | 50.18.9.15.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 40 mmdia 10Kgf/cm2- External work- Exposed on wall |
| 15 | 50.18.9.16.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 10Kgf/cm2 - External work - Exposed on wall |
| 16 | OD40762/2025-2026Supply and fixing 1" PVC valve and other accessories |
| 17 | OD40760/2025-2026Supply and fixing 1.5" PVC valve and other accessories |
| 18 | OD40764/2025-2026Supply and fixing 2" PVC valve and other accessories |
| 19 | OD40761/2025-2026Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 40mm dia Elbow |
| 20 | OD40763/2025-2026Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 40 mm dia Tee |
| 21 | OD40759/2025-2026Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 50 mm dia Elbow |
| 22 | OD40765/2025-2026Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipesincluding jointing with PVC solvent cement - 50mm dia Tee |
| 23 | OD40766/2025-2026Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 50x40 mm dia Reducer |
| 24 | 18.48Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes but without fittings and the basesupport for tank |
| 25 | 19.18.1Supplying and fixing C.I with out frame for manholes:455 x 610 mm rectangular C.Icover ( light duty ) the weight of the cover to be no less than 23 kg |
| 26 | FABRICATION OF IRON STAIRCASE-CIVIL WORKS |
| 27 | 2.31Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees andsaplings of girth up to 30 cm measured at a height of 1 m above ground level andremoval of rubbish up to a distance of 50 m outside the periphery of the area cleared |
| 28 | 2.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposedearth to be levelled and neatly dressed.All kinds of soil |
| 29 | 4.1.3Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarsesand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 30 | 10.2Structural steel work riveted, bolted or welded in built up sections, trusses and framedwork, including cutting, hoisting, fixing in position and applying a priming coat ofapproved steel primer all complete. |
| 31 | 13.61.1Painting with synthetic enamel paint of approved brand and manufacture to give aneven shade:Two or more coats on new work |
| 32 | 15.7.4Demolishing brick work manually / by mechanical means including stacking ofserviceable material and disposal of unserviceable material within 50 metres lead asper direction of Engineer-in-Charge.In cement mortar |
| 33 | 14.1.1Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters andunder, including cutting the patch in proper shape, raking out joints and preparing andplastering the surface of the walls complete, including disposal of rubbish to thedumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : finesand) |
| 34 | 13.43.1Applying one coat of water thinnable cement primer of approved brand andmanufacture on wall surface:Water thinnable cement primer |
| 35 | 9.147C.1Providing and fixing factory made uPVC white colour casement/ Casement cumfixed glazed door comprising of uPVC multi-chambered frame, sash and mullion(where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thickgalvanized mild steel section made from roll forming process of required length(shape & size according to uPVC profile), uPVC extruded glazing beads ofappropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hingesand one handle on each side of panels along with zinc plated mild steel multipoint locking having transmission gear, cylinder with keeps and one side key,G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessarystainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusionwelded at all corners, mullion (if required) shall be also fusion welded includingdrilling of holes for fixing hardware's and drainage of water etc. After fixingframe the gap between frame and adjacent finished wall shall be filled withweather proof silicon sealent over backer rod of required size and of approvedquality, all complete as per approved drawing & direction of Engineer-in-Charge.(Single / double glass panes and silicon sealent shall be paid separately).Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable.Casement door with3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both havingwall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead ofappropriate dimension. (Area of door upto 2.00 sqm). |
| 36 | OD40789/2025-2026Supplying and fixing Chequered plate 3MM Thickness fixing in position andapplying a priming coat of approved steel primer all complete |
| 37 | CONSTRUCTION OF PUMP HOUSE-CIVIL WORKS |
| 38 | 2.31Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees andsaplings of girth up to 30 cm measured at a height of 1 m above ground level andremoval of rubbish up to a distance of 50 m outside the periphery of the area cleared |
| 39 | 2.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposedearth to be levelled and neatly dressed.All kinds of soil |
| 40 | 2.25Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 41 | 4.1.8Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4coarse sand : 8 graded stone aggregate 40 nominal size) |
| 42 | 7.1.1Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarsesand) |
| 43 | 50.6.1.8Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etccomplete |
| 44 | 5.9.5Centering and shuttering including strutting, etc. and removal of form for:Lintels,beams, plinth beams, girders bressumers and cantilevers |
| 45 | 5.9.3Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform |
| 46 | 5.2.2Reinforced cement concrete work in walls (any thickness), including attachedpilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. up tot floor five level excluding cost of centering,shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 gradedstone aggregate 20 mm nominal size) |
| 47 | 5.22A.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo - MechanicallyTreated bars of grade Fe-500D or more |
| 48 | 13.7.212 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1cement : 4 fine sand) |
| 49 | 50.13.19 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost ofmaterials, labour charges etc complete |
| 50 | Applying one coat of water thinnable cement primer of approved brand andmanufacture on wall surface:Water thinnable cement primer |
| 51 | 13.60.1Wall painting with acrylic emulsion paint of approved brand and manufacture to givean even shade:Two or more coats on new work |
| 52 | 13.47.1 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additivesof required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over andincluding priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 53 | 13.61.1Painting with synthetic enamel paint of approved brand and manufacture to give aneven shade:Two or more coats on new work |
| 54 | 11.40Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm ormore (thickness to be specified by the manufacturer) of Ist quality conforming to IS:15622 of approved make in all colours, shades, except white, Ivory, Grey Fume RedBrown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) includingpointing the joints with white cement and matching pigments etc., complete. |
| 55 | 9.1.3Providing wood work in frames of doors, windows, clerestory windows and otherframes, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia & length (hold fast lugs or dash fastener shall be paid forseparately).Kiln seasoned and chemically treated Hollock wood |
| 56 | 9.5.2.2Providing and fixing panelled or panelled and glazed shutters for shutters for doors,windows and clerestory windows, including ISI marked M.S. pressed butt hingesbright finished of required size with necessery screws, excluding panelling which willbe paid for separately, all complete as per direction of Engineer - in-charge.30 mmthick shutters |
| 57 | 9.48.2Providing and fixing M.S. Grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steelprimer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc |
| 58 | 9.76Providing and fixing bright finished brass 100 mm mortice latch and lock with 6levers and a pair of lever handles of approved quality with necessary screws etc.complete |
| 59 | 9.55.1Providing and fixing ISI marked M.S. pressed butt hinges bright finished withnecessary screws etc, complete:125x65x2.12 mm |
| 60 | 9.66.1Providing and fixing ISI marked oxidised M.S. handles conforming to IS : 4992 withnecessary screws etc. complete:125 mm |
| 61 | 9.74.1Providing and fixing bright finished brass tower bolts (barrel type) with necessaryscrews etc. complete:250x10 mm |
| 62 | 9.147D.4Providing and fixing factory made uPVC white colour sliding glazed window upto1.50 m in height dimension comprising of uPVC multi-chambered frame with in-builtroller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thickgalvanized mild steel section made from roll forming process of required length(shape & size according to uPVC profile), appropriate dimension of uPVC extrudedglazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy(white powder coated) touch locks with hook, zinc alloy body with single nylonrollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixingframe to finished wall and necessary stainless steel screws etc. Profile of frame &sash shall be mitred cut and fusion welded at all corners, including drilling of holesfor fixing hardware's and drainage of water etc. After fixing frame the gap betweenframe and adjacent finished wall shall be filled with weather proof silicon sealentover backer rod of required size and of approved quality, all complete as per approveddrawing & direction of Engineer-in-Charge. (Single / double glass panes, wire meshand silicon sealent shall be paid separately)Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimensioni.e. in depth & width of profile shall be acceptable.Three track three panels slidingwindow with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels)made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wallthickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead ofappropriate dimension. (Area of window above 1.75 sqm). |
| 63 | CONSTRUCTION OF PUMP HOUSE-ELECTRICAL WORKS |
| 64 | 1.10.3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C |
| 65 | 1.7.4Wiring for circuit/ sub main wiring along with earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 66 | 1.7.6Wiring for circuit/ sub main wiring along with earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2 X 16 sq. mm + 1 X 6 sq. mm earth wire |
| 67 | 90.11.1.21Supply and installation of sheet steel, phosphatised and painted, dust and verminproof enclosure of MCB DB including copper /brass bus bar, neutral link, earth busand DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitableanchor bolts or fixed in recess including cutting hole on the wall , making good thedamages, colour washing etc. as required12 way (8+12) - double cover TPN verticalDB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP42/43) |
| 68 | 5.4Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick includingaccessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt asrequired |
| 69 | 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps |
| 70 | 2.10.3Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCB DBcomplete with connections, testing and commissioning etc. as required.Double pole |
| 71 | 2.14.3Supplying and fixing following rating, double pole, (single phase and neutral), 240volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes inthe existing MCB DB complete with connections, testing and commissioning etc. asrequired.63 amps |
| 72 | OD40807/2025-2026Supplying and fixing Single Tube set ( Electronics ) and other accessories |
| 73 | OD40806/2025-2026Supplying and fixing 48; Ceiling fan and other accessories Please Enable Macros to View BoQ information |