| 1 | Labour for cleaning the work site before and after work etc. |
| 2 | Earth Work in excavation in Foundation Trenches in Ordinary soil |
| 3 | Filling in foundation trenches and plinth in layers. Not exceeding 150 |
| 4 | Excavating supplying and filling of local earth (including royalty) by mechanic |
| 5 | Supplying chemical emulsion in sealed containers including deliveryChlorpyriphos/Lindane emulsifiable concentrate of 20% |
| 6 | Diluting and injecting chemical emulsion for POST-Along extemal wall where the apron is not provided usingWith Chlorpyriphos/Lindane E.C. 20% with 1% |
| 7 | Providing and laying in position cement concrete of specified grade 1:4:8 (1 Cement: 4 coarse sand (zone-III) 8 graded stone aggregate 40 mm nominal size |
| 8 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 |
| 9 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement All work up to plinth level.1:1.5:3 (1 cement 1.5 coarse sand (zone-ill): 3 graded stone |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15\\" landings, balconies, shelves, chajjas, lintels bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centening. shuttering, finishing and reinforcement, with 1.1.5:3 (1 cement. 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal Size |
| 11 | Centering and shuttering including strutting, propping etc. and Foundations, footings, bases of columns, etc. for mass concrete |
| 12 | Suspended floors, roofs, landings, balconies and access platform. |
| 13 | lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 14 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 15 | Small lintels not exceeding 1.5m clear span, moulding as in cornices, |
| 16 | Edges of slabs and breaks in floors and walls. Under 20 cm wide |
| 17 | Providing Tor steel reinforcement of 8mm. dia. rods as per approved |
| 18 | Providing Tor steel reinforcement of 10mm. dia. rods as per approved |
| 19 | Providing Tor steel reinforcement of 12mm. to 25 mm. dia. rods as |
| 20 | Providing designation 100A brick work with flyash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:6) in super structure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints costs of screening materials, scaffolding, raking out joints to 15mm depth curing taxes and royalty all complete as per building specification and direction of Ε/I. |
| 21 | Providing designation 112mm thick reinforced designation 100A brick |
| 22 | Extra for providing & placing in position 2 no 6mm dia ms bar every |
| 23 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Fixing with adjustable lugs with split end tail to each jamb |
| 24 | Providing and fixing aluminium work for doors, windows, ventilatorsPowder coated aluminium (minimum -do-For shutters of doors, windows & ventilators including providing and -do- |
| 25 | Powder coated aluminium (minimum |
| 26 | With float glass panes of 5 mm thickness (weight not |
| 27 | Filling the gap in between aluminium frame & adjacent RCC/Brick/ Upto 5mm depth and 5 mm width |
| 28 | Supplying, fitting and fixing 35mm thick solid core type non decorative |
| 29 | Supplying, fitting and fixing 35mm thick solid core type decorative |
| 30 | Providing and fixing aluminium extruded section body tubular type |
| 31 | Supplying fitting and fixing aluminium fittings of approved quality and -do- 300mm sliding Door Bolt |
| 32 | 250mm Sliding Door Bolt |
| 33 | Providing and fixing aluminium hanging floor door stopper ISI marked Twin rubber stopper |
| 34 | (anodic coating not less than grade AC 10 as per IS: 1868) transparent or |
| 35 | Providing and fixing bright finished brass 100 mm mortice latch and |
| 36 | 3.0 mm thick & 2100 mm long with SS screws etc .complete as per Powder coated minimum thickness 50 micron aluminium tubular |
| 37 | Providing and laying 25mm. thick kota stone slab flooring(iv) 600X600 mm Size |
| 38 | Providing and laying 25mm. thick kota stone tiles in risers |
| 39 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to |
| 40 | Providing and laying rectified Glazed Ceramic floor tiles of size |
| 41 | Providing and laying, Doublecharge vitrified floor tiles in different |
| 42 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Antiskid 600X600 |
| 43 | Water. proofing for Old and New Roof Slab :- Providing and laying(a) surface preparation-Providing and cleaning of concrete surface to(b)1st Cost:- Apply 1st coat of two component acrylic modified, ready(c) :2nd Coat-To apply the 2nd coat of two component acrylicThe Waterproofing Brand: \\"Silca Topseal 109hi/ Fosroc Brushbond4624) Slant-Shear Bond Strength -4 N/mm2 (According to FIP 5.15)D Protection of treated with pcc:- The treated surface shourd beall comers shall be charfered with 150mm X 150 mm fillet. The rain(e) Groove of PCC surface should be filled with Polysulphide Sealant |
| 44 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of |
| 45 | Providing 19 mm thick water proof cement plaster (1:3) with clean |
| 46 | Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse |
| 47 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 48 | Distempering with 1st quality acrylic distemper (ready mixed) having -do- New work (Two or more coats) -do- |
| 49 | Finishing walls with Premium Acrylic Smooth exterior paint with New work (Two or more coat applied @ 1.43 Itr/ 10 sqm over and |
| 50 | Providing precast cement concrete Jali 1:2:4 (1 cement: 2 coarse sand(zone-III): 4 graded stone aggregate 6mm nominal size), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1.3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits.40 mm thick |
| 51 | CHIPS |
| 52 | BRICKS |
| 53 | SUBHEAD-I: Sanitary InstallationsSupplying fitting and fixing 40mm high vitreous white glazed earthen E.W.C. with 'p' trap of parry hindustan or any other approved I.S.S. make including supplying and fixing 15 litres C.L. mosquito proof low down flushing cistern of approved make with complete fittings with C.L.handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450grams 15mm P.V.C. alkathene pipe 45cm. long with brass coupling at both ends and white/black plastic solid state seal and lead of commander/cuckoo or other 1.5.S. make with hinges or screws etc painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming all complete as per specification and direction of E/L.e.w.c with s trap10 ft low level pvc cistern |
| 54 | Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other 1.S.S. approved make supported on painted C.L. or R.S. brackets 32mm C.L.brass waste 15 mm dia C.L. body brass spindle stop cock of approved quality of weight not less than 350grams 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/L |
| 55 | Providing and fixing white vitreous china laboratory sink with Cl brackets C.P brass chain with rubber plug 40 mm C.P brass waste and 40 mm CP brass trap with necessary C.P brass unions complete including painting of fittings and brackets cutting and making good the wall wherever requiredSize 600x450x200 mm |
| 56 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. |
| 57 | Providing & fixing PVC waste pipe for sink including PVC waste fitting CompleteFlexible Pipe32mm Dia |
| 58 | Providing and fixing PTMT liquid soap container 109 mm wide 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms. |
| 59 | Providing & fixing PTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealed fittings arrangement of approved quality and colour weighing not less than 88 gms |
| 60 | Providing and fixing C.P. brass bib cock of approved quality confirming to IS 8931 |
| 61 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms15mm nominal bore |
| 62 | Providing and fixing cp brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a) 15 mm nominal bore15 mm nominal bore |
| 63 | providing and fixing toilet paper holderc.p brass |
| 64 | Providing and fixing flanged cleanout plug with M.S. flanged tail pieces blind flang 6mm dia nut & bolts gasket and washers fixed to C.I. Pipe with drip seal joint complete in all complete including cutting and making good the walls and floor wherever required with 10 mm dia pipe |
| 65 | Providing and fixing uplasticised PVC connection pipe with brass unions45 cm length15 mm nominal bore |
| 66 | Providing & fixing rain water Khurras' size 450x450 mm required depth with lead flashing around the pipe with one piece lead sheet of 3 mm thick set on a layer of cold bitumen Including Heavy duty CI/MS grating as per drawing complete as required. |
| 67 | SUBHEAD-II(A): INTERNAL DRAINAGE INSTALLATIONSSupplying fitting and fixing H.C.I. pipes with ear of approved make confirming to LS.I. 1729 including supplying nails and bobins short pieces cutting loose collars lead and yarn for making lead caulked joints cutting pipes to size including earth work or scaffolding where necessary etc. all complete as per specification and direction of Pl(a) 100 mm dia |
| 68 | (b) 75 mm dia |
| 69 | c) 50 mm dia |
| 70 | Supplying and fixing H.C.L. fittings of approved make confirming to 1.s.s 1729 including supplying nails and bobines lead and yam from making lead caulked joints including earth work or providing scafolding as case may be all complete as per specification and direction of e/i(A) H.C.L. single junction with door but without ear except socket(a) 100 mm dia (wt. 10.5 Kg. app.) |
| 71 | (B) H.G.I. Heal Rest bend(1) 100 mm dia (wt. 5.5 Kg. app.) |
| 72 | Supplying all tools and labours and cutting chajja, Cornice, for laying H.C.L. pipes and making good the same as per Specification and direction of E/1. |
| 73 | Cutting drain width wise above G.L. for laying H.C.L. pipe and restoring brick work in cement mortar (1:4) 12mm cement plaster in (1:4) with neat cement punning as per specification and direction |
| 74 | Making holes in walls for laying H.C.L pipes and restoring the same after pipe laying as per specification and direction of E/1.(a) 125mm dia |
| 75 | Supplying materials and labour for painting the exposed H.C. pipes and fittings with 2 coats of approved paint over a coat of red oxide primer etc, all complete as per specification and direction of E/1.(a) 50 mm dia |
| 76 | (a) 80 mm dia |
| 77 | (a) 100 mm dia |
| 78 | Providing, Fixing, testing and commissioning of UPVC pipe SWR type 'B' conforms to IS: 13592-1992 with all fittings such as bends, tees, elbow, 'Y', offset, cleaning pipe door, clamps and steel structural supports etc. including cutting the floors, walls and making good the same in cement concrete 1:2:4 & cement mortar 1:4. The wall thickness of pipe and technical characteristic conforms to IS: 13592-1992 type 'B'. The fitting dimension conforming to IS: 14735-1999. The jointing to be completed with rubber ring joint/solvent weld Joint110 mm (OD) SWR Pipe |
| 79 | SUBHEAD-III(A): WATER SUPPLY INSTALLATIONSProviding and fixing G.I. pipes complete with Gl fittings and clamps including cutting and making good the walls etc. (Exposed on wall Terrace)25 mm nominal outer dia pipes |
| 80 | Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jonting of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the wall same including testing of joints complete as per the direction of engineer incharge Concealed work including cutting chases and making good the wall etc.15 mm nominal outer dia pipes |
| 81 | 20 mm nominal outer dia pipes |
| 82 | 25 mm nominal outer dia pipes |
| 83 | Providing and fixing of gun metal gate valve with Cl wheel of approved quality32 mm dia, nominal bore |
| 84 | Painting Gl pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality25 mm dia, nominal bore |
| 85 | Providing and fixing G.I. union in G.I. pipe including cutting and threading the pipe and making long screw etc complete 32mm nominal bore |
| 86 | Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design. |
| 87 | Constructing masonry Chamber 60x45x50 cm,inside with 75 classdesignation brick work in cement mortar 1:5 (1 cement:5 fine sand) for water meter complete with C.J. Doble flap surface box 400x200x200mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement: 2 corase sand: 4 graded stonr aggregate 20mm nominal size) necessary excavation foundation concret 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortor 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard designWith F.P.S. bricks |
| 88 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.J. grating brick masonry chamber with water light C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:180 x 150mm size P-typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 89 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1) cement: 2 fine sand including testing of joints etc.complete150 mm dia R.C.C. pipe |
| 90 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement: 4 coarse sand) with R.C.C. top slab with 1:1.5:3 mix (1 cement: 1.5 coarse sand (zone- III): 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement: 4 coarse sand (zone-III): 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neatInside size 90 x 80 cm and 45 cm deep including Cl cover with frame (light duty) 455 x 610mm intemal dimensions total weight of cover and frame to be not less than 38 Kg. (weight of cover 23 Kg. and weight of frame 15 Kg.). with EPS bricks with class desionation 75With common bunt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 91 | Size 120x90 cmConstructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement:4 coarse sand) in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 mix (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement all complete as per standardConstructing brick masonry road gully chamber 50x45x60cm with bricks in cement mortar 1:4 (1 cement: 4 coarse sand) including 500x450mm precast RCC horizontal grating with frame complete as per standard design.With common bumt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 92 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank IS: 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet outlet and overflow pipes but without fittings and the base support for tank |
| 93 | FIRE FIGHTING WORKSSUBHEAD-4.0: FIRE EXTINGUSHERProviding storing handling shifting installation testing and commissioning of portable fire Extinguishers as described below.4.5 kg carbon dioxide extinguisher IS marked with high pressure discharge tube horn control valve CCE approved cylinder |
| 94 | 6 kg Mono Ammonium Phosphate (ABC) type cartridge operated extinguishers |
| 95 | INTERNAL ELECTRICAL WORKWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit with modular switch modular plate suitable Gl box etc as required.Group C |
| 96 | Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC condult alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 97 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit as requiredCIRCUIT/SUBMAIN WIRING2x1.5 sq mm + 1x1.5 sq mm earth wire |
| 98 | 2x2.5 sq mm + 1x2.5 sq mm earth wire |
| 99 | Supplying and drawing co-axial TV cable RG-6 grade 0.7 mm solid copper conductor PE insulated shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 100 | Supplying and foxing of following sizes of PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25mm dia |
| 101 | 32mm dia |
| 102 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.5/6 amps one way switch |
| 103 | 15/16 amp one way switch |
| 104 | 5/6 amp 3 pin socket outlet |
| 105 | 5/16 amp 6 pin socket outlet |
| 106 | TV anteena Socket Outlet |
| 107 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 108 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 109 | Supplying and fixing following size/ modules, Gl box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (78mm x 78mm x 45mm) - For Telephone & TV outlet. |
| 110 | 4/5 Module (78mm x140mm x 50mm) |
| 111 | 8/9 Module (78mmX230mmx60mm) |
| 112 | Supplying and fixing 2 pin 5 Amp Ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 113 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 114 | Supplying and fixing Ding dong sound call bell single phase 230 volts complete as required. |
| 115 | Installation testing and commissioning of pre wired fluorescent fitting / Compact fluorescent fitting off all type complete with all accessories and tube etc directly / wall including connection with 1.5 sq.mm FR PVC insulatted copper conductor single core cable and earthing etc. as required. |
| 116 | Installation testing and commissioning of ceiling fan including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated copper conductor single core cable etc. as required. |
| 117 | Installation of exhaust fan up 450 mm sweep in the existing opening including making the hole to suit the size of above the fan making good the damage connection testing commissioning etc. as required. |
| 118 | Supplying and fixing following ways horizontal type three pole and neutral sheet steel MCB distribution board 415 volts on surface/recess complete with tinned copper bus bar neutral bus bar earth bar din bar interconnections powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 Way (4+18) Double Door Horizontal Type |
| 119 | Supplying and fixing 6 Amp to 32 Amp rating 240 volts 10 KA \\"C\\" Curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections testing and commissioning etc. as required.6/32 Amp Single Pole |
| 120 | 6/32 Amp TPN |
| 121 | 40 Amp TPN |
| 122 | Supplying and fixing of following rating double pole (Single pole & neutral) 240 volts resudual current circuit breaker (RCCB) having a sensivity current 30 miliampere in the existing MCB DB complete with connections testing & commissioning etc as required.63 Amps |
| 123 | Providing and foxing M.V. danger Notice plate of 200mm x 150 mm of made of mild steel at least 2 mm thick and vitreous enamelded white on both side and with inscription in single red colour in front side as requird |
| 124 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required. |
| 125 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required |
| 126 | SUPPLY & INSTALLATION OF LIGHT FIXTURES & FANSS.I.T.C of following rating surface mounted LED Tube Lighting Fitting Suitable for 230V 50 Hz Single Phase Supply etc. complete as required.10/12 W LED Tube Light |
| 127 | 20/22 W LED Tube Light |
| 128 | SITC of 300 mm (12\\") Exhaust fan (Metal body) suitable for single phase 230 volts 50 Hz AC supply complete with motor louvers/shutters etc. complete as required. Make -> Usha/Crompton/Havells. |
| 129 | Supply Installation Testing & Commissioning of following sizes ceiling fan 3 Blades confirming to IS:374:2019 including wiring the down rods of standard (up to 30cm) with 1.5 sq.mm FR PVC insulated copper wire suitable for 230V 50 Hz Single phase supply etc. complete as required. Make- Usha/Crompton/Havells1200 mm (48) BLDC 5 Star rating 32W Ceiling Fan |
| 130 | Septic Tank 50 usersEarthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling, ramming the foundation trenches, removing roots of trees shurbs all complete as per approved design building specification and direction of E/I.all kinds of soil |
| 131 | Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item -B) |
| 132 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/L (Mode of measurement compacted volume) |
| 133 | Providing designation 75Bwork in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.m. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials ranking out joints to 15mm depth, curing taxes and royalty all complete as per building specification and direction of E/I. |
| 134 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plinth level 1:2:4 (1 Cement: 2 coarse sand (zone-III): 4 graded stone aggregate 40 mm nominal size) |
| 135 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 136 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15\\" landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 137 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 138 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15\\" landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 139 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 140 | Providing Toe steel reinforcement of 10mm to 16mm dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL, TATA Steel, JSPL, Electro Steel Ltd. and Vizal Steel)10mm dia |
| 141 | 12 mm dia |
| 142 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I |
| 143 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/Л. |
| 144 | Providing 1.5mm cement punning including curing, carriage of water with 5.7.11 all leads and lifts as per building specification and direction of E/L. |
| 145 | (i) Bricks Lead (1 K+7 P)8 km |
| 146 | (ii) SAND av.LEAD 10 K.M |
| 147 | (iii) Stone chips lead = 22 km |
| 148 | (v)Local Sand lead-3km |
| 149 | HYDTSupplying all materials, labours and tools and equipment for drilling 200 X 165mm dia. X 125 Mtr. bore well in all kinds of soil and rock in urban area for installation of pumps set with Hydraulic DTH Rig Machine, all complete including drilling rig, Air Compressor and equipments, as well as fuel, lubricants and cost of transporation of rig machine and over vehicles up to the site etc. all complete job as per specification and direction of E/lc.From 0-50 Meter |
| 150 | From 51-125 Meter |
| 151 | Supplying all tools, tackles & lowering of 200mm dia. MS ERW casing pipe of 6mm wall thickness including welding charges, cost of pipe etc including all taxes, VAT, Excise duty, freight charges with inspection charges etc as applicable, etc. all complete job as per specification and direction of E/lc. |
| 152 | Supplying all materials: labours, tools & equipments for fiting & fixing 200mm dia MS cap over casing pipe etc. all completes job. |
| 153 | Cleaning flushing and developing of drilled hole for testing the discharge of water development of bore well by continuous flow of water by using heavy compressor up to satisfaction of E/l. to get uninterrupted flow of water free from sand and soil etc. |
| 154 | Supplying of 150mm dia 03.00 H.P. (ISI Mark) KSB/Kirlosker/CRI/V-guard Submersible Motor Pump sets comfirming to IS 8034 and motor confirming to IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415V + 10%, 3PH, 50Hz, A.C. supply with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided. The pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined non returned valve shall be provided with pump. 3 meter submersible copper in single/double run shall be provided with each pump.(up to 20 stages) Supply rate should be increased by Rs 200/-per stage for pump with more than 20 stages. |
| 155 | FR PVC insulated 3 core 4 sq. mm. copper wire |
| 156 | Supplying of 32mm Submersible Pipe of standard make Ashirwad/Raksha/Prince/Gupta or any equivalent make for above requirement. |
| 157 | Supplying of 02 Nos. clamp, Band, Adopter, Bore Cover etc. as required for above work. |
| 158 | Supplying & Providing Rope of required size & tape. |
| 159 | Supplying & Fixing of BCH Make or Equivalent Panel Board with all accessories & Iron Box with Angle Stand and its fixing as per direction of E/l. |
| 160 | Installation Charges for Lowering of Motor Pump. |
| 161 | Supplying and of 10.0sq.mm Alluminium cable ISI mark as per specification and direction of E/l. (for connection from main line to electric Meter. |
| 162 | Good & Service Tax (GST) |
| 163 | Labour Cess Please Enable Macros to View BoQ information |