| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with wooden switch board with bakelite cover and piano type switch including connection etc as required:- |
| 2 | Short Point :- |
| 3 | Medium Point :- |
| 4 | Long Point :- |
| 5 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required. |
| 6 | 2 X 1.5 sq mm |
| 7 | 2 X 2.5 sq mm |
| 8 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- |
| 9 | 1 X 1.5 sq mm |
| 10 | Supplying and fixing of the following PVC casing capping with all accessories etc. as required. |
| 11 | 25mm x 12mm |
| 12 | Supplying and fixing of the following sizes PVC conduit (medium gauge) on surface with all accessories etc. as required. |
| 13 | 19/20 mm dia |
| 14 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required. |
| 15 | 5/6 amps piano type switch |
| 16 | 3 pin 5/6 amps piano type socket |
| 17 | 2.5 mfd fan capacitor |
| 18 | 32 amps DP kit kat switch:- |
| 19 | Supplying and fixing of the following sizes wooden switch boards with 3mm thick bakelite cover etc. as required. |
| 20 | 102mm x 102mm (4\\" X 4\\") :- |
| 21 | 102mm x 178mm (4\\" X 7\\") :- |
| 22 | Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\\"x 12\\" having locking arrangement including CC work, holes on earth pipe etc. as required. |
| 23 | Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required. |
| 24 | Supply and fixing of 25mm x 5mm GI strip on wall/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals. |
| 25 | Supplying of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades (Without regulator) (ISI marked, BEE 1 star/minimum service value 4.0m3/min/W) : - |
| 26 | Installation, testing and commissioning of ceiling fan including wiring the down rod of standard length (up to 30 cm) by 2 x 1.5 Sq.mm PVC insulated copper conductor cable(FR) etc as required. |
| 27 | Supplying and fixing of the following luminaries (Surface/Recess) including necessary accessories and connection with 2x1.5 sq.mm PVC insulated coper conductor cable(FR) etc. as required. |
| 28 | Bulk head fitting with diecast aluminium alloy body and heat resistant glass cover suitable for GLS/ CFL(without lamp). |
| 29 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 30 | Surface mounted integrated 20 watt LED batten with polycarbonate diffuser:- |
| 31 | Surface mounted round/Square shaped 18/20 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
| 32 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 33 | 60 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 34 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:- |
| 35 | 9 watt LED retrofit lamp with polycarbonate body and aluminium heatsink |
| 36 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required. |
| 37 | 2 way SPN MCB DB (single door):- |
| 38 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required |
| 39 | 6 to 32 amps DP MCB:- |
| 40 | Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required:- |
| 41 | 3 core 4 Sq mm |
| 42 | Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:- |
| 43 | 40 amps DP isolator:- |
| 44 | Supplying and fixing of the following sizes PVC switch boards with cover etc. as required. |
| 45 | 75mm x 75mm (3\\" X 3\\") :- |
| 46 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:- |
| 47 | 25 mm dia |
| 48 | Excavation of earth for cable trench of 800mm depth & 300mm width in all kinds of soil including back filling of cable trench with the excavated soil with 20cm layer of sand, 3.5 nos bricks per metre for protection including ramming, consolidating to the original shape as per dirrection of Site Engineer :- |
| 49 | Drawing of armoured/un-armoured cable with proper saddling etc as required |
| 50 | Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:- Please Enable Macros to View BoQ information |