| 1 | Complete removal of existing roof treatment from RCC roof including old hussion felt, tiles etc and preparation of surface with bire brush and cleaning with water complete all as directed. |
| 2 | Material and Labour for 10mm thick cement paster in CM 1:4 mixed with WPC finised even and smooth without using extra cement on roof surface and wall (WPC will be measured and paid seperately as supply only ). |
| 3 | Supply only liquid water proofing compound. ISI Marked |
| 4 | M&L for applying a coat of bitumen primer @ 0.3L/sqm on roof surfaces. complte all as specified and directed |
| 5 | M&L for applying 3mm thick APP modified polymeric membrane over the bitumen coat surface weight not less than 3kg/sqm and over lap 100mm and sealed by torch application as per manufacture insteructions complte all as specified and directed |
| 6 | M&L for applying two coats aluminium paint over bituminous surface of membrane |
| 7 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.complte all as specified and directed |
| 8 | M&L for rendering 15 mm thick in cement mortar 1:4 on wall of brick work or concrete surface, finished fair and even all as specified and directed. |
| 9 | M&L for rendering 10 mm thick in cement mortar 1:6 on wall of brick work or concrete surface, finished fair and even all as specified and directed. |
| 10 | M&L for rendering 5 mm thick in cement mortar 1:3 on ceiling of brick or concrete surface, finished fair and even all as specified and directed. |
| 11 | M&L for preparing new plastered surfaces and applying two coats of distember oil emulsion white or tinted over 1mm thick putty after one coat of white primer complete all as specified and directed. |
| 12 | M&L for preparing of old surfaces, washing, rubbing down and stopping of disstempered and painted surfaces and applying two coats of distember oil emulsion on wall over 1mm thick putty complete all as specified and directed. |
| 13 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.complte all as specified and directed |
| 14 | M&L for cleaning ther old surface of all the dirt and green algae with wire brush without disturbing the old plaster and then Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over Old surfaces. complte all as specified and directed |
| 15 | Material and labour for preparation of OLD plastered surfaces of ceiling and applying three coats of white wash complete all as specified & directed. |
| 16 | Material and labour for preparation of NEW plastered surfaces of ceiling and applying three coats of white wash complete all as specified & directed. |
| 17 | M&L for repair and rendering 10mm thick in CM 1 :3 on chajjas, facia, roof projection, column sides, beam bottom and sides including throating after removing cracked plaster and concrete including cleaning of viisible reinforcement and treating with cement slurry also necessary repair to cracked concrete if any with cement concrete 1:2:4 Type B-0 using 12.5mm graded stone aggregate including necessary scafolding work for double/single storey bldgs all as directed . |
| 18 | Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) n.exc 1.50 Sqm each.complte all as specified and directed |
| 19 | S&F Powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weeighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fitings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed. |
| 20 | S&F in repairs decorative curtain rod made out of 25mm dia (outer dia) MS pipe having wall thickness 0.63mm, PVC coated of any colour and pattern as approved overall dia 28 to 28mm, includiing and including two nos brackets on each ends alongwith globe on each ends for earch window/door fro fixing complete all as specified and directed with fancy design and approved by GE. |
| 21 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safecustody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. etc complete all as specified and directed. |
| 22 | Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6 sqmm from surface/concealed at any height and removing the materials from site and making good the disturbed surfaces of walls,floors roofs etc complete all as specified and directed. |
| 23 | Taking down Old/ Unserviceable MCB DBs SPN/TPN/ Main Switches by disconnection of electric connection including old unsv MCCBs,MCBs, isolators etc and making good to distrubed surface complete all as specified and directed. |
| 24 | M&L point wiring for One light/Fan point controlled by one five amps one way single pole switch complete with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed FRLSH cable 1100 Volts grade , drawn through PVC concealed conduit 20/25 mm dia on wall/ceiling ,including replacement by new modular sheet top covers and sunk type CI/steel terminal boxes ,cromium plate screw as suitable size for mounting of switch & scoket including 1.5 sqmm size pvc insulated unsheathed copper conductor to common earth and connecting to earth dolly complete all as specified and directed.Note: The rate quoted is deemed to be included for modular sheet and steel terminal box, for fixing of switch and scoket including cutting chases in wall making good to disturbed surface and matching with existing surfaces. |
| 25 | All as per Ser item No 24 here-in-before but one 3 Pin Socket out let 5 Amps on the same board. |
| 26 | All as per Ser item No 24 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board. |
| 27 | All as per Ser item No 24 here-in-before but point wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly. |
| 28 | S&F Switch modular 1 way 6 Amps single pole complete all as specified & directed. |
| 29 | S&F Switch modular single pole , one way 16 Amps complete all as specified and directed. |
| 30 | S&F Socket modular 2/3 pin combined 6 Amps complete all as specified and directed. |
| 31 | S&F Socket modular 2/3 pin combined 6/16 Amps complete all as specified & directed. |
| 32 | S&F Ceiling rose, 3 terminal PVC/polycarbonate complete all as specified and directed. |
| 33 | S&F modular Fan step regulator 230 Volts single phase 120 watt, 2 module complete all as specified and directed. |
| 34 | M&L for submain complete with 2x4 sqmm, single core, multi stranded copper conductor , PVC insulated and unsheathed FRLSH cable 1100 Volts grade, drawn in with and including PVC concealed conduit 20/25 mm dia as per site requirement along walls/ceiling etc including 4 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. Note:- (i) all three wire(Phase red colour,neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs(ii) painting over surface conduit to be done to match with walls/ceiling existing surfaces. (iii) Two run of wire (phase & neutral) and one run of wire (earth conductor) be measured as one length) |
| 35 | Supply and fix MCB DB SPN 8 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed at site. |
| 36 | Supply and fix MCCB DB VTPN 4 way with metal door suitable for Provision of incommer and out going MCCBs/MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed. |
| 37 | Supply and fix in replacement MCCB 100 Amp 415 volts 16kA 4 pole complete all as specified and directed. |
| 38 | S&F in replacement of MCB SP 6 to 32 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed. |
| 39 | S&F in replacement of MCB DP 40 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles. |
| 40 | S&F in replacement of isolator DP 63 Amps 'C' Series fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed. |
| 41 | S&F in replacement of LED tube light fitting 20 watt 230 Volt decorative ultra slim linear LED Lighting with aluminium housing & integrated electronic driver , including all internally pre-wired and inncluding connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed at site. |
| 42 | S&F exhaust fan steel body AC single phase, 230Volts of size 300 mm sweep complete with louver shutter and including making of hole suitable size fan base after cutting of brick/stone wall /suitable size of water proof ply wood complete all as specified and directed. |
| 43 | S & F Ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep, Min air dilivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 44 | S&F in replacement of building LED security light fitting 25 Watt in aluminium pressure die cast aluminium housing with high power LED as lightning sourse and lens embedded PC Cover having IP 65 protection and impect resistance of IK07 with 10 KV Built in super protection device. luminaire with high power LED as light source including suitable size of GI bracket fixed with two Nos GI clamp nut,bolt,washer etc complete all as specified and directed at site. |
| 45 | Supply, Laying on replacement ,connecting, testing and commissioning of XLPE LT UG cable of size 35 sqmm 3 1/2 core PVC insulated and sheathed armoured heavy duty cable 1100 V grade with alu conductor cable all as directed. |
| 46 | Excavation in trenches in loose/soft soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables, poles/stays and struts etc and getting out including trimming sides and forming bottom surface complete, all as specified. |
| 47 | Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified. |
| 48 | Returning & filling in including spearing, leveling watering and well ramming in layers not exc 25cm thick |
| 49 | Supply and Spread dry river sand for cable cushioning in trenches all as specified and directed. Note : Punned down thickness shall be considered for measurement |
| 50 | Supply and lay burnt bricks sub class ‘B’ old size laid dry in trenches across the cable protection all as specified and as directed Please Enable Macros to View BoQ information |
| 51 | Supply and lay burnt bricks sub class ‘B’ old size laid dry in trenches across the cable protection all as specified and as directed Please Enable Macros to View BoQ information |