| 1 | M&L for cement concrete (type B2 1:2:4, 40 mm graded aggregate) as in foundations, filling and mass concrete including Demolition of cement concrete in ground floor & paving, n. exc 15 cm thick (below or above GL), unreinforced complete all as specified and directed and removing debris outside MD land complete all as specified and as directed by Engr-in-Charge |
| 2 | M&L for PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete and like etc including demolition of cement concrete in ground floor & paving, n. exc 15 cm thick (below or above GL), unreinforced complete all as specified and directed and removing debris outside MD land complete |
| 3 | M & L for 75mm thick cement concrete (1:2:4) type B-2, using 40mm graded stone aggregate as in plinth protection and finishing the surfaces even and smooth without using extra cement, including necessary expansion joints, filled solidly with a hot mixture of blown grade bitumen and sand 1:1 by weight including Demolition of cement concrete in ground floor & paving, n. exc 15 cm thick (below or above GL), unreinforced complete all as specified and directed and removing debris outside MD land complete |
| 4 | M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia orsecuring with clips and including welding has to be done with minimum 20 cm over lap for new and Old unserviceable of any height complete all as specified and as directed by Engr-in-Charge. |
| 5 | M & L for mild steel TMT bars 6 to 10 dia as in stirrups, spaces and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends andbinding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed by Engr-in-Charge. |
| 6 | M&L for providing reinforced cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in kitchen slab,landing, Chajja or in any position including Demolition of cement concrete (reinforced) of any position not otherwise specifically provided for and including reinforcement required to facilitate demolition upto and including fourth story and on the roof top/mumty/parapet and removal of debris and rubbish out side MoD land complete all as specified and directed. |
| 7 | Providing and fixing special water tight centering and shuttering including bolting, strutting, propping etc. so as to withstand a pressure of 0.1 Mpa including removal of form from all locationsincluding beams, columns, slabs, walls, foundations, footings, landings, stairs, balconies etc. complete all as specified and as directed by Engr-in-Charge. |
| 8 | Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles and removing debris out side MD land complete all as specified and directed by Engg-in-charge. |
| 9 | M & L for brick work in CM 1:4 using Sub class ‘B’ Bricks straight or curved on plan any radius in half brick thick wall complete all as specified and directed. |
| 10 | M & L for Except Brick work with sub class 'B' bricks, straight or curved on plan, exc 6 mtr mean radius, built in CM 1:6 complete all as specified and directed by Engg-in-charge. |
| 11 | M & L for Brick work with sub class 'B' bricks, straight or curved on plan, exc 6 mtr mean radius, built in CM 1:6 complete all as specified and directed by Engg-in-charge. |
| 12 | M&L for rendering 10 mm thick plastering in cement mortar 1:3 as in ceiling finished even and smooth without using extra cement to match with existing surface including taking down cement plaster including all necessary scafffoldingcomplete all as specified and directed. |
| 13 | M&L for rendering 15 mm thick in cement mortar 1:6 on fair face of brick work/ concrete surfaces (either surfaces) of wall and finished even and smooth without using extra cement including Taking down cement plaster of any description from brick wall surfaces etc including racking out joints and hacking for key, scrubbing down with water etc including all necessary scaffolding arrangments of any height complete all as directed. |
| 14 | M&L for rendering 15mm thick rendering in cement mortar 1:4 on fair face of brick work/ concrete surfaces of wall with water proofing admixture finished even and smooth without using extra cement (WPC will be measured and paid separatly) including Taking down cement plaster of any description from brick wall surfaces etc including racking out joints and hacking for key, scrubbing down with water etc including all necessary scaffolding arrangments of any height complete all as directed. |
| 15 | Supply only liquid water proofing compound complete all as specified and directed. |
| 16 | Taking down Chowkhats or frames n.exc 1.50 sqm each (without taking off shutters from the frames) complete all as specified and as directed by Engr-in-Charge |
| 17 | Taking down Chowkhats or frames, exc 1.50 sqm but n exc 4.00 sqm each (without taking off shutters from the frames) complete all as specified and as directed by Engr-in-Charge. |
| 18 | Taking down shutters of any description n exc 1 sq. m each complete all as specified and directed. |
| 19 | Taking down shutters of any description exc 1 sq. m and n exc 2 sqm each complete all as specified and directed. |
| 20 | Supplying and fixing factory made single extruded WPC (Wood Polymer Composite) solid door Frames/Chowkhat comprising of 100 mm X 50 mm size, applying PVC solvent cement and screwed with full body threaded, star headed SS screws having minimum frame density of 750 kg/cum and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and as directed by Engr-in-Charge |
| 21 | S & F factory made single extruded WPC (Wood Polymer Composite) solid door Frames/Chowkhat comprising of 125 mm X 65 mm size applying PVC solvent cement and screwed with full bodythreaded star headed SS screws having minimum frame density of 750 kg/cum and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and as directed by Engr-in-Charge |
| 22 | S & F factory made single extruded WPC (Wood Polymer Composite) solid door Frames/Chowkhat comprising of 45 x 70 mm size applying PVC solvent cement and screwed with full bodythreaded star headed SS screws having minimum frame density of 750 kg/cum and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and as directed by Engr-in-Charge |
| 23 | S & F factory made 28-30 mm thick single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size, modulus of elasticity 850 N/mm” and resistance to spread offlame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full bodythreaded star headed counter sunk S.S screws complete all as specified and as directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
| 24 | S & F factory made 28-30 mm thick single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size, modulus of elasticity 850 N/mm” and resistance to spread offlame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full bodythreaded star headed counter sunk S.S screws complete all as specified and as directed by Engr-in-Charge. Please Enable Macros to View BoQ information |