Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Demolition of cement concrete in ground floors and paving not exceeding 15cm thickness (below or above ground level) un- reinforced, complete all as specified and directed. |
| 2 | M&L for Cement Concrete 1:2:4, type B-1 (20mm graded stone aggregate) 25mm thick as in sub-base, sub flooring, Flooring, complete all as specified and as directed. |
| 3 | Demolition of stone or brick masonry built in cement mortar including all quoins, arches etc. But excluding ashlar facing, dressed stone work etc, complete all as specified and directed. |
| 4 | M&L for Brickwork with fly ash Old size bricks straight or curved on plan exec 6m mean radius, built in cement mortar 1:6 , complete all as specified and directed. |
| 5 | All as per ser item no 4 here in before but except bricks, completed all as per specified and as directed. |
| 6 | M & L for Brick work with Sub class 'B' , straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4 complete all as specified and as directed. |
| 7 | M&L for 75mm thick plain cement concrete 1:3:6, type C2, using 40mm graded crushed stone aggregate as in plinth protection, laid in slope of 1:12 and surface finished even and fair without using extra cement including making all necessary form work to divide the area in panel, finishing exposed edges fair or rounding or chamfering where directed and providing 6mm wide joints through out the thickness of plinth protection dully filled (comprising one part hot blown bitumen 85/25 and two part of sand) , complete all as specified and directed. |
| 8 | Taking down chowkats or frames including shutters (without taking off shutters from the frame) not exc. 1.5 Sqm each, complete all as specified and directed. |
| 9 | Taking down chowkats or frames including shutters (without taking off shutters from the frame) exc. 1.5 Sqm but n exec 4.0 sqm each, complete all as specified and directed. |
| 10 | M&L for Pressed steel frames of size 105mmx60mm made of 1.25mm thick Cold Rolled sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, complete all as specified. |
| 11 | M&L for Pressed steel frames of size 125mmx60mm made of 1.25mm thick Cold Rolled sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, complete all as specified. |
| 12 | M&L for factory made single extruded WPC (Wood Polymer composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with mitre joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length, complete as per direction of Engineer-in-Charge. Note-(i) M.S. hold fast/ lugs or SS dash fasteners shall be included.(ii) For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 13 | S&F factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as per direction of Engineer-In-Charge. Note: Stainless steel butt hinges and necessary S S screws shall be paid separately. |
| 14 | M&L for PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in hold fast iron fixing and back filing of pressed steel door frame including necessary form work all as specified. |
| 15 | S&F35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides fitted to chowkats, complete all as specified. |
| 16 | S&F 35mm thick factory made 2nd class hardwood glazed and skeleton shutters open rebated and prepare to receive glass gauge (without sash bars) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass/gauge etc size of member etc size members of shutters as specified in SSR part I Section-8 clauses 8.24(b) supplied and fitted to chowkhat, complete all as specified and directed. |
| 17 | S&F Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplied and fitted in openings as per specification and drawing shown in SSR Part-II, complete all as specified. |
| 18 | S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made of MS tube for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement from stiles and plain colour PVC sheet to be fitted with MS frame welded/sealed to the styles & rails with suitable PVC sheet beading, and jointing together with solvent cement, supplied & fitted in the frame at site as per specification & drawings shown in SSR Part-II, complete as specified. |
| 19 | S&F extruded aluminium alloy handle, fabricated type, anodised, 100mm long , complete all as specified. |
| 20 | S&F aluminium anodised, barrel tower bolt of extruded section and fixed, 150mm long , complete all as specified. |
| 21 | S&F butt hinges, stainless steel 100mm long (ISI marked), complete all as specified and directed |
| 22 | S&F extruded aluminium alloy handle, fabricated type, anodised, 150mm long (ISI marked), complete all as specified. |
| 23 | S&F aluminium anodised, barrel tower bolt of extruded section and fixed, 200mm long (ISI marked), complete all as specified. |
| 24 | S&F aluminium alloy, 16mm dia and 250mm long anodised, sliding door bolt with hasp, staple (bolt type) with and fixing clips of sheet, cast or excluded sections and fixing bolts and sliding bolts of excluded sections or cast aluminium alloy and fixed, complete all as specified.(ISI Marked) |
| 25 | S& F 300mm mild steel ordinary rat tail rod pattern springs including roller and roller plate, fixed including welding/ fixing to steel/ wooden chowkats, complete all as specified and directed. |
| 26 | M&L for door seal rubber beading 75 mm wide 4 mm thick for fixing with door shutter and similar situation including necessary drilling and cutting etc, complete all as specified and directed. |
| 27 | Excavating in soft/loose soil for post holes (or similar holes) each n exec 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and as directed. |
| 28 | M&L for PCC 1:3:6 type C2 (Using 40mm graded stone aggregate)as in foundations, filling and mass concrete, complete all as specified and directed by Engineer –in-Charge. |
| 29 | Dismantling mild steel work of any description not otherwise provided for complete all as specified and directed by Engr-in-Charge |
| 30 | S & F mild steel work in tubular trusses including angle , flat iron and tube of any size special shaped washers etc., complete using but ERW or induction butt welded tubes confirming to Fe-410W(GdeE-250) quality B complete all as specified and directed. |
| 31 | Dismantling damaged/unserviceable Galvalume, AC and Fiber Sheeting of any gauge and thickness, complete all as specified and as directed. |
| 32 | M&L for pre painted galvalume aluminium zinc coating having GI based corrugated steel sheets 0.50mm thick of any colour tensile strength of 550 Mpa as in roof covering/cladding to wall with self tapping screw complete all as specified and directed by Engr-in-charge. |
| 33 | S&F aluminium powdered coated window and ventilator shutters, sliding type with four track (two track with and including stainless steel wire cloth and fixed with tinned tacks or aluminium wire staples, two track with and including 5 mm thick tined glass including necessary fitting and fixture) without sash bars, aluminium sections of size 40x20x1.5 mm fixed in aluminium anodised double frame of section size 63X35X2 mm including necessary jointing cleats, glazing clips, aluminium anodised sap beading, screws, aluminium beading, pvc packing, aluminium anodised fitting and fixture including powder coating of thickness n.exc 50 micron on all aluminium section complete all as specified and directed. |
| 34 | S&F Powder coated aluminium door shutter having 82mm x37mm x 1.5 mm thick bottom rail, 82mm x37mm x 1.5 thick middle rail, 82mm x37mm x 1.5 thick vertical stile and top rail including necessary fitting joinery cleat, glazing packing snap beading 10 mm x 10 mm ,anodized aluminium handle 200 mm long (02 Nos) , 3 Nos 100 mm size chromium plated butt hinges, 2 Nos 200mm size Alu tower bolt, 1x aluminium alloy, 16mm dia and 250mm long anodised, sliding door bolt with hasp, staple (bolt type), 1x double legged floor door stopper aluminium alloy body and tongue, etc including frame of section 82mm x37mm x 1.5 and door shutter, top and bottom portion covered with and including 5.5mm thick tint glass ordinary quality , one mortice lock with shutter and fixing complete all as specifies and directed. |
| 35 | S & F of Aluminium die cast body door closer hydraulically regulated designation No. 3, universal type suitable for door shutter 851 to 1000 mm in width and 61 to 80 Kg in weight complete all as specified and directed. |
| 36 | S& F factory made box type glazed and gauged steel window/ventilator made out of ERW hollow P&T section. Both window to be welded together with flat iron 25x3mm to outer frames on both sides complete all as specified and shown in drawing No CEAF/STD-184/2012 Sheet No 1/3, 2/3 & 3/3, including MS grill and necessary formwork complete and including shop coat red oxide primer with following fittings welded to frame/shutter:-(a) Hold fast 150mm long 25mmx6mm iron made to shape-02 Nos in each window (both sides)(b) Handle of 'Z' section 20mmx25mm Each leaf(c) 100mm stopper-01 No per leaf.(d) MS tower bolt 150mm long - 02 Nos in each leaf.(e) Cleat 55mm long of hollow square 15mmx15mmx24mm welded to hinges gauze wall thickness welded to hinges of 50mm size-01 No per leaf.(f) MS box type hinges of size 75x12mm-03 Nos per leaf(g) Fabrication & fixing complete(h) Flat iron for fixing wire gauge to gauge window Glass pane, wire gauge and synthetic enamel painting work complete.Note:- (i) Glass panes, wire gauze and painting shall be measured & paid Separately under respectiveii) Design shall be got approved from the Engineer-in-charge as per Drg No CEAF/STD-184/2012 Sheet No 1/3, 2/3 & 3/3 before fabrication and bulk order to the manufacturer. |
| 37 | S&F Stainless Steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks, wire staples or beading etc, complete all as specified and directed. |
| 38 | S&F in repair Stainless Steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks, wire staples or beading etc, complete all as specified and directed. |
| 39 | M&L for sheet glass 3mm thick ordinary quality and glazing with oil putty or wooden beads in squares not exc. 0.5 Sqm in each pane, complete all as specified and directed. |
| 40 | M&L for figured glass, pin headed type, 3mm thick and glazing with oil putty or wooden beads in squares not exc. 0.5 Sqm in each pane, complete all as specified and directed. |
| 41 | M& L for 18mm thick solid HDHMR board with 0.9-1.20mm thick sun mica laminated sheet both side of two different colours (colour finish) as in kitchen cabinet shutter, jointed to form cabinet by means of Adhesive Solvent and fixed using Self-tapping Aluminium Screws, including bedding, providing & fixing of Stainless steel hinges suitable for 18 mm HDHMR Board (minimum of 02 Nos for Each leaf ) to hold cabinet shutter , Stainless Steel Silver chrome Door Handle 100mm long (01 No for each leaf of shutter) and Door catcher (01 no for each leaf), complete all as specified and as directed. NOTE: Quoted unit Rates are inclusive of HDHMR board, handles, hinges, screws, Door catcher and adhesive etc. |
| 42 | Taking down cement plaster on brick or concrete wall surfaces etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 43 | M&L for 5 mm thick rendering in cement mortar 1:3 on concrete surfaces of roof projection ceiling etc up to 6m height and surface finished even and fair without using extra cement, complete all as specified and directed. |
| 44 | M&L for 15 mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even and fair without using extra cement as on wall complete all as specified and directed. |
| 45 | M&L for 15 mm thick rendering in two layers i.e. 10 mm thick in cement mortar 1:4 plus 5 mm thick in cement mortar 1:4 mixed with approved water proofing compound on fair faces of brick surfaces or concrete surfaces, surface finished even and fair without using extra cement all as specified and directed.Note :Water proofing compound shall be measured & paid separately. |
| 46 | M&L for preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white wash, complete all as specified and directed. |
| 47 | Preparation of newly plastered wall surfaces of any description complete all as specified and M& L for applying Two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted ) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surface. |
| 48 | M&L for preparation of new plastered surfaces of wall and applying two coats of oil emulsion distemper over and including 2 mm thick wall care putty to achieve smooth finish surface, complete all as specified and directed. |
| 49 | M&L for complete removal of existing treatment from wall surfaces and applying two coats of oil emulsion distemper over and including 2 mm thick wall care putty to achieve smooth finish surface complete all as specified and directed. |
| 50 | M&L for preparation of plastered or unplastered old decorated surfaces on ceiling including cornices pilasters, applying two coat of white wash on ceiling complete, all as specified and directed. |
| 51 | M&L for Complete removal of existing treatment of any description, and M& L for applying Two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted ) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm ,complete all as specified and directed. |
| 52 | M&L for preparation of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed. |
| 53 | M&L for preparation of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint , complete all as specified and directed. |
| 54 | M&L for preparation of new or previously untreated wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and directed. |
| 55 | M&L for preparation of old painted surfaces, of wood and wood based material of any description over 10cm width and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 56 | M&L for preparing old painted surfaces of steel and iron surfaces, over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 57 | Demolition of reinforced cement concrete of any description in any position not otherwise specifically provided for (Reinforcement cut as required to facilitate demolition), complete all as specified. |
| 58 | M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs, shelves, landing and similar work not exceeding 200mm thick (horizontal or sloping) and to edges of concrete surface fair finished complete all as specified and as directed. |
| 59 | M&L for Reinforced cement concrete, type B-1 (1:2:4) nominal mix, using 20mm graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified. |
| 60 | M&L for TMT mild steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for column, hooking end and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 61 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed. |
| 62 | M&L for coloured glazed ceramic tiles of approved shade of size 450 x 300 mm x 7 thick as in vertical surface etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 10mm thick rendering in cement mortar 1:4, complete all as specified and directed. |
| 63 | M&L for non skid colour ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11 Sqm but n exec 0.18 Sqm, in flooring etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed. |
| 64 | M&L for non skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.18 Sqm but n exec 0.38 Sqm, in flooring etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed. |
| 65 | M&L for Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, laid on vertical surfaces such as skirting, dados and risers to steps etc laid over and including 10mm thick cement plaster in CM (1:4) set and jointed in neat cement ,complete all as specified and directed by the Engineer in Charge. |
| 66 | M&L for vitrified light shade ceramic tiles 10 mm thick (square/rectangular) area of each tiles exceeding 0.42 Sqm but n exec 1.00 Sqm, in flooring etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed. |
| 67 | M&L for vitrified light shade ceramic tiles 10 mm thick (square/ rectangular) area of each tile exceeding 0.42 Sqm but not exceeding 1.00 Sqm, laid on vertical surfaces such as skirting, dados and risers to steps etc laid over and including 10mm thick cement plaster in CM (1:4) set and jointed in neat cement paste ,complete all as specified and directed by the Engineer in Charge. |
| 68 | Demolition of stone slabs/paver block and tiles of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar, complete all as specified and directed. |
| 69 | M&L for machine cut Kota stone slab flooring 18-20 mm thick over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab, laid over and including 20mm thick screed bed in cement mortar 1:6, rubbing, grinding and polishing complete all as specified and directed. |
| 70 | M&L for Kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab, laid over and including 10mm thick rendering in cement mortar 1:4, rubbing, grinding, rounding of edges and polishing , complete all as specified and directed.Note : Kota stone shall be laid in one piece for treads and risers for step, and moulding/rounding of edge properly. |
| 71 | M&L Granite 20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like machine cut , laid over and including Cement Screed 10mm thick in Cement Mortar 1:4, cutting and Granite Polishing using White Cement in Joints including rounding Edge of Stone Slab on One Edge, complete all as specified and as directed.NOTE : Cost of Cement Screed Bed shall deem to be include in the Quoted Unit Rate. |
| 72 | S&F in repair stainless steel 20-25 mm dia drapery curtain rod including brackets and end knobs fixed with plugs & screws, complete all as specified and directed. |
| 73 | S&F in repairs Vitreous Chinaware squatting pan, Orissa pattern size 580mm x 440mm with integral foot rests, white, with cast iron ‘P’ or ‘S’ trap, front or back inlet, including provision of cement concrete, making connections to trap and to flush pipe etc. and making good to floors, complete all as specified and directed. |
| 74 | Supply and fix in repair Vitreous China wash down water closet pan (Pedestal pattern incl one toilet paper holder, one health faucet and jet ingrate controlled by two way angle valve) incl plastic water closet seat white colour closed pattern with flat bottom and cover and MS CP aluminium/PVC hinging devices complete all as directed and specified by Engr-in-charge. |
| 75 | S&F in repairs, PVC valveless, syphonic action type flushing cistern, 10 litres capacity, plunger type, low level, white with inlet, ball valve, float , 32 mm dia PVC long bend flush pipe 90cm long, complete all as specified and directed. |
| 76 | S&F in repairs stop valves(concealed) , 15mm bore, fancy type, chromium plated, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., complete all as specified and directed. |
| 77 | S&F in repairs angle valves, 15mm bore, fancy type, chromium plated, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., complete all as specified and directed. |
| 78 | S&F in repairs PVC connection 15mm dia, 600mm long, hot water grade with brass chromium plated nuts and washers at both ends, complete all as specified. |
| 79 | S&F in repairs Brass chromium plated shower rose of 125mm size with or without swivel joints with arms suitable for 15mm bore pipe, complete all as specified. |
| 80 | S&F in repairs Under counter wash hand basin vitreous China white oval shape size 440X525X195mm including PVC waste coupling 32mm size, PVC waste pipe 32mm bore complete making good the surface / joints with white cement complete all as specified and as directed. |
| 81 | S&F in repairs, wash hand basin vitreous China flat back 550 x400 mm size white, first quality, with and including PVC waste coupling 32mm size, PVC waste pipe 32mm bore, including complete fitting to walls all specified and as directed. |
| 82 | S&F in repair, looking mirror of 8mm thick properly grinding and rounding on edges with including all pivots to wall for properly fixed as per manufacture instructions, complete all as specified and directed. |
| 83 | S&F in repairs bib tap, 15mm bore, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed. |
| 84 | S&F in repair Vitreous China urinals, full stall type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; |
| 85 | S&F 15mm bore, Kitchen/WHB mixer fancy type, chromium plated, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with or without lettered `Hot’ or 'Cold’ with long screwed shanks and fly-nuts, screwed for iron pipe, complete all as specified. |
| 86 | S&F in repairs Gun-metal, globe or gate valves of 20mm dia, with iron wheel head, screwed both ends for iron pipe, complete all as specified. |
| 87 | S&F in repairs soap dish, brass chromium plated, complete all as specified and directed. |
| 88 | S&F in repairs towel rail brass chromium plated, 20mm dia, D type, 60cm long between flanges, complete all as specified and directed. |
| 89 | S&F Acrylic corner set of 3 pieces as per sample approved by Engr -in-charge all as specified and directed |
| 90 | S&F sheet glass 5.5 mm thick WHB Shelf 600 mm long and 125 mm wide as per sample approved by Engr -in-charge complete all as specified and directed. |
| 91 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc. complete all as specified and directed by engineer in charge |
| 92 | S&F PVC (SWR) pipes, 110mm dia, single socketed, in any length with rubber ring joints, fixed to wall ,including clamps complete all as specified & directed |
| 93 | S&F 110mm bore PVC (SWR) bends/ door bends any radius, complete all as specified and directed. |
| 94 | S&F 110 mm bore PVC (SWR) junction single (Single T ) with access door equal or unequal, complete all as specified. |
| 95 | S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including suitable clamps after every one meter of interval, complete all as specified and directed. |
| 96 | S&F PVC (SWR) pipes, 75 mm dia, single socketed, in any length with rubber ring joints, laid in floor , complete all as specified & directed |
| 97 | S&F 75 mm bore PVC (SWR) bends with access door any radius, complete all as specified and directed. |
| 98 | S&F 75 mm bore PVC (SWR) junction single (Single T ) with access door qual or unequal, complete all as specified. |
| 99 | S&F 110 mm bore PVC (SWR) vent cowl, complete all as specified. |
| 100 | S&F PVC (SWR) floor trap 75 mm , plain with grating including jointing with solvent cement complete all as specified and directed. |
| 101 | Taking up or down GI tubing with all connections and fittings of 15mm bore , complete all as specified and as directed by Engineer-in-Charge |
| 102 | Taking up or down GI tubing with all connections and fittings of 20mm bore complete all as specified and as directed by Engineer-in-Charge |
| 103 | S&F galvanized iron water tubing, ‘medium grade’ 15mm bore, with all fittings such as bend, tee, union etc., fixed complete to walls and ceilings or laid in floors, complete all as specified & directed. |
| 104 | S&F galvanized iron water tubing, ‘medium grade’ 20mm bore, with all fittings such as bend, tee, union etc., fixed complete to walls and ceilings or laid in floors, complete all as specified & directed. |
| 105 | Refixing old steel tubing of 15mm bore and connections in new or old position (Walls, ceiling, floors etc.), complete all as specified and directed. |
| 106 | Refixing old steel tubing of 20mm bore and connections in new or old position (Walls, ceiling, floors etc.), complete all as specified and directed. |
| 107 | Dismantling water tank of capacity exec 500 and n exec 1000 litre of any type, PVC/RCC/MS complete all as specified and directed. |
| 108 | S&F rotationally moulded polyethylene white colour triple layer water storage tank (cylindrical vertical with closed top) hoisted & fixed in position of capacity 1000 litters including ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed for 20mm bore pipe, complete all as specified and as directed. |
| 109 | Dismantling of Brick tiles or terracing tiles in roof , single layer on roofs ,complete all as specified and as directed. |
| 110 | Demolition of Mud phuska in roofs, any thickness, including plastering and leaping (whether full thickness removed or only a part thereof) , complete all as specified and as directed. |
| 111 | Cleaning of exiting surface by suitable means and other contaminants manually to attain a fairly smooth and protrusion free surface. Any protrusions shall be removed prior to laying of waterproofing membrane , joints to be grouted should be clean and dust free. Wherever required, remove the old tile grout before proceeding with new grouting |
| 112 | M&L for PCC (1:2:4), type B-0, using 12.5mm graded crushed stone aggregate as in PCC in roof kerbs,& mud stops, complete all as specified. |
| 113 | M & L for chase open construction joints in V shape of 15mm*15mm using suitable means, later cleaning the same using water jet and applying a bond coat of latex bonding agent and cement modifier mixed with cement and water in a ratio of 1:1:3 (water :Polymer: Cement), followed by filling of latex bonding agent and cement modifier admixed PMM in the groove, including, filling, finishing, curing all complete as per the direction of Engineer In-Charge. Adhesive Application:- Providing and applying 2-pack, solvent-free, thixotropic epoxy adhesive is a 2 pack solvent free epoxy resin system consisting of a off white base and black hardener in pre-weighed quantities for easy onsite mixing. The base and hardener into a suitable container shall be emptied and mixed with a paddle and slow speed heavy duty drill, ensuring the sides are scraped down. A uniform grey colour should be obtained after mixing thoroughly The mixed adhesive is applied to both surfaces to be bonded with a serrated trowel or other suitable spreader. The joint should be closed immediately, if this is not achieved the surface of the adhesive should be slightly scratched immediately prior to closing the joint to expose fresh adhesive. The joint must be closed within recommended. the open time of the adhesive . on sight monitoring of the operation using lapped asbestos cement panels is recommended. |
| 114 | M&L for Providing and laying 1.5mm thk high-performance, loose-laid, reinforced TPO (Thermoplastic Polyolefin) waterproofing membrane on the well cleaned and undulation free surface. The TPO membrane individual roll shall be laid over 300GSM, geotextile laid over the prepared surface. All additional membranes shall then be laid with its overlaps of 50mm fixed using hot air welding machine. In case of mechanically fixed TPO membrane, the side overlaps shall be minimum 100mm. Entire terrace area shall then be covered using reinforced TPO waterproofing membrane in a similar manner. Item includes termination, sealing of earthing post and other ancillaries proposed as per manufacturer's methodology. including geotextile of 300GSM over the existing surface. The termination details shall be discussed at site, once before membrane fixing. Termination and membrane laying shall be done as per manufacturer's approved methodology.The waterproofing TPO membrane shall be BBA certified and shall have:1. Tensile strength (ASTM D412)Longitudinal: > 10N/mm2Transversal: > 10N/mm22. Elongation at break (ASTM D412 and EN 12311-2)Longitudinal: >900%Transversal: >750%3. Puncture resistance: Pass test > 800mm (EN 12691 dynamic)4. Water impermeability: Pass test (EN 1298)5. Water impermeability: Pass out (EN 12691 dynamic)6. Water vapour transmission: Nil (ASTM 96)7. Tear resistance (EN 12310-1) Longitudinal: 530 N Transversal: 1.5mm - 600 N8. Root resistance: Pass test - no penetration9. Lap joint strength: Pass test-broken out joint (EN 12317 and UEATC), Durability: Pass test 2500hrs |
| 115 | M&L for termination of geotextile on the parapet wall using 1.5 mm thick, 25 mm wide aluminium strip fixed with suitable fasteners at 250 mm centres. The termination will be done on the parapet wall of around 300 mm height and sealed using a PU sealant in accordance with the manufacturer's instructions and the approved methodology. |
| 116 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 117 | M&L for cement concrete Type- E2 (1:5:10) using 40 mm graded aggregate in filling and mass concrete as in sunken portion all as specified and directed . |
| 118 | M&L for 15mm thick cement screed in CM 1:3 with liquid-based integral waterproofing admixture designed for concrete and mortar of approved make with ratio as specified by the manufacturer and latex acrylic polymer emulsion used as a high-performance bonding agent, cement modifier, and curing aid for concrete and mortar of approved make with ratio as specified by the manufacturer complete all as specified and as directed. |
| 119 | M&L for applying two coats of acrylic-based polymer water proofing coating of approved make with ratio as specified by the manufacturer on the entire surface of sunken portion all as specified and as directed. |
| 120 | M&L for galvanized iron spout pipe 40mm dia projecting at least 20cm clear of wall ‘medium grade’ including making holes in walls & making good disturbed surfaces, complete all as specified & directed. |
| 121 | Supply liquid water proofing compound (ISI marked), complete all as specified and directed. |
| 122 | M &L for chipping of spalled and loose concrete and cleaning rust from reinforcement by sand blasting scrubbing down concrete surface with wire brushes cleaning with water alloy to dry and applying a layer of zinc rich epoxy primer as in anti rush on all exposed reinforcement followed by a layer of binding coat of epoxy adhesive on complete exposed surface of concrete to be gunited and applying a layer of guniting over steel welded mesh 2mm dia. of wire and aperture 75mm. Total thickness of guniting n exc. 40mm dia. in per manufacture instruction and finally applying 15 mm thick CM 1:4 cement plaster over guniting surface of required thk to give even surface as in side , soffits to slab, chajjas, facia, parapets, lintels, columns, and beams, complete including necessary scaffolding, shuttering, chasing to brick work or RCC members at any height up to 6 storied building including removal of all small trees /shrubs etc., completed all as specified and as directed . |
| 123 | S&F 12 mm Toughened glass as in partitions and similar work including cutting to shape, drilling holes required. Complete, all as specified & directed by Engr -in charge, |
| 124 | S&F 12 mm thick toughened glass for door with proper grinding and rounding of edges , incl two no of stainless steel handle in each leaf ,handle size length 45cm and 25mm dia. With locking arrangement, hydraulic machine at the bottom and pivots as per manufacture instruction, completed all as specified and as directed . |
| 125 | Dismantling of wall and ceiling or insulation boards/ slabs / PVC panelling any thickness and in any position incl frame grid and cover fillets and framework etc complete all as specified and directed. |
| 126 | S&F for PVC Wall panelling louvers consisting of 8mm thick solid Plain/ colour PVC sheet inclusive of solvent cement and fixing at site including 5mm thick PVC sheet fillet of width 35mm frame work at a distance of 600 mm c/c. Complete all as specified & directed by Engr -in charge. |
| 127 | S&F 9mm thick perforated gypsum board/ Tile of size 600x600mm with aluminium foil another side over and including grid form GI power coated (605mm x605mm) with T section of size 24 x38x 2 mm (both cross and main) and angle of size 25 x26x2mm properly fixed to wall and fixed to ceiling with 10GA GI vertical hangers @300mm C/C again which tie up with ISA 32x32x3m @300mm C/C properly with the help of 2 no 16mm dia. 120mm long dust fastners, completed all as specified and as directed. |
| 128 | S&F 12mm thick plain gypsum board false ceiling with GI frame work including all necessary drilling, cutting to fix electrical items complete all as specified and directed with followings:-(a) GI sheet channel 30x25x20mm of 24 Gauge fixed with rawl plug and screws 450mm centre to centre along with perimeter of walls. b) GI sheet channel made to shape 50x40x40mm of 24 gauge placed @ 600mm centre to centre from perimeter of wall except long wall (in one span)(b) GI sheet channel made to shape 50x40x40mm of 24 gauge placed @ 600mm centre to centre from perimeter of wall except long wall (in one span) (c) GI sheet intermediate runners of size 45x10x10mm of 24 gauge fixed @ 1200mm centre to centre leaving frame of one side wall (in other span) (d) GI sheet 25mm wide & 20mm gauge suspenders fixed with steel fasteners to roof, ceiling @ 1200mm centre to centre incl plugging in RCC slab. Complete including tapping work with two coat of oil bound distemper with & incl 2mm wall care putty complete all as specified & directed by Engr-in-charge. |
| 129 | M&L of Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors. Complete all as specified and directed. |
| 130 | M&L Of voids in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing wall. Complete all as specified and directed. |
| 131 | Excavation in trenches, not exceeding 1.5M wide and not exceeding 1.5 M in depth for foundation etc and getting out in Soft/loose soil complete all as specified and as directed. |
| 132 | Removing excavated materials to a distance not exceeding 50 meters and depositing where directed at level not exceeding 1.5 meters above the starting point complete all as specified and as directed. |
| 133 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm using excavated soil complete all as specified and as directed. |
| 134 | M&L for PCC 1:4:8 type D-2(using 40mm graded stone aggregate ) in Cement concrete in foundations, filling and mass complete all as specified and as directed. |
| 135 | M & L for Plain cement concrete type B1 1:2:4 ( using 20 mm graded granite stone aggregate) Copings, bed plates and the like including weathering, slightly surface with gunny bags to remove all loose dirt etc. complete all as specified and as directed. |
| 136 | M & L for Brick work with Sub class 'B' , straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4 complete all as specified and as directed. |
| 137 | M&L for double wall corrugated drain pipe DWCP (SN8) 180mm (OD)/150 mm (ID) diameter, (ISI marked) drain pipes laid in trenches and tested incl fitting of same grade complete all as specified |
| 138 | M&L for double wall corrugated drain pipe DWCP (SN8) 230mm (OD)/200 mm (ID) diameter, (ISI marked) drain pipes laid in trenches and tested incl fitting of same grade complete all as specified |
| 139 | M & L for Plain cement concrete 1:3:6 type C2 (using 40mm graded granite stone aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after thy are laid and tested for 150mm dia bore complete all as specified and as directed. |
| 140 | M & L for Plain cement concrete 1:3:6 type C2 (using 40mm graded granite stone aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after thy are laid and tested for 200mm dia bore complete all as specified and as directed. |
| 141 | M & L for Precast cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in landing, cover slab (for man holes etc) shelves and similar articles with plain faces and set in CM (1:4) including use & waste of formwork complete all as specified and as directed. |
| 142 | Material and labour for cutting into existing manholes for connecting new drains, or septic tank for removing existing branch drain, making good to walling and rendering, cutting out branch channel, all as specified for (a) 150mm bore pipes |
| 143 | Material and labour for cutting into existing manholes for connecting new drains, or septic tank for removing existing branch drain, making good to walling and rendering, cutting out branch channel, all as specified for (a) 200mm bore pipes |
| 144 | M & L for P.C.C 1:2:4 type B1 (using 20 mm graded stone aggregate) as in surface channels and drain, complete all as specified and as directed. |
| 145 | M&L for Cement concrete type D- 2, 1:4:8 (40mm graded aggregate) 75 mm thick in sub base, flooring, paving's etc complete all as specified and as directed. |
| 146 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and as directed. |
| 147 | M&L for coloured rubberized Chequered cement concrete tiles 300X300X(20-22)mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigments including 15mm thick screed bed or bedding layer in Cement Mortar (1:6) as in floor finished even and rough to receive the top layer complete all as specified and as directed by Engr-in-Charge |
| 148 | Preparation of newly plastered wall surfaces of any description complete all as specified and M& L for applying Two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/ltr and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted ) with silicon additives @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10 sqm complete all as specified |
| 149 | S&F in repair 25 mm thick precast cement concrete 1:2:4 type B0 ( using 12.5mm graded stone aggregate ) designer Jafri wall jallies as per sample , area of each not exec .5 sqm fixed on wall in cement mortar 1:4 including two coat cement base paint in plain pattern to match the shade with old Jafri wall complete ass as specified and directed |
| 150 | S&F Framed Work as in Gates or doors of Angle or Other Section with Gusset Plates, Rails, Braces, etc., drilled for fixing of Steel Sheeting or Other Covering. Doors, etc. to be prepared for hanging or sliding with and including either Hooks and Hinges or Steel Hanging Door Fittings (exclusive of Steel Sheeting or Other Covering, Running Rails and Guides) and hanging; also fastening and fixing, conforming to Fe-410-W (Gde E-250), Quality A, complete all as specified and as directed. |
| 151 | Taking down carefully unserviceable copper/aluminium point wiring (light, fan, socket or power)complete including fixture and fitting such as switches, ceiling rose lamp holder, regulators, sockets, light fittings, wooden terminal boxes, plastic laminated sheet cover, including taking down of DB’s, meter board any type all as specified and as directed. |
| 152 | Dismantling and taking down fluorescent tube light single/double of any wattage or size fitting for repair or replacement of burnt/worn out accessories or carrying to MES store(Accessories or components to be provided free for replacement by department), complete all as specified and as directed. |
| 153 | Taking down unserviceable sub main wiring of any type/size including wires, conduits/batten etc, complete all as specified and as directed. |
| 154 | Taking down unserviceable DB's box including MCB's of any size/rating, complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 155 | Taking down unserviceable DB's box including MCB's of any size/rating, complete all as specified and as directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail