Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Demolition of un-reinforced cement concrete of any description and in any position not otherwise specially provided for complete all as specified and directed. |
| 2 | Demolition of cement concrete of Sunken portion/EWC/IWC of any description and in any position not otherwise specially provided for complete all as specified and directed. |
| 3 | Demolition of unreinforced cement concrete in ground floors and pavings not exceeding 15cm thickness (below or above ground level) complete all as specified and directed. |
| 4 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) in Man holes, roof slabs, chajjas, beams , fascias, fins and similar works complete all as specified and directed. |
| 5 | Dismantling floor, hearth or wall/stone tiling including cement mortar bedding (but not backing), removing broken tiles and rubbish off the premises from site complete all as specified and directed. |
| 6 | Demolition of brick work built in cement mortor including all quoins,arches,pillars etc complete all as specified and directed. |
| 7 | Taking up or down existing 15mm bore steel water tubing and connections,including clreaning for refixing or removal, fixed/laid in any situation, complete all as specified and directed. |
| 8 | Taking up or down existing 20mm bore steel water tubing and connections,including clreaning for refixing or removal, fixed/laid in any situation, complete all as specified and directed. |
| 9 | Dismantling structural steel work in cluding doors, gates but excluding framed truss etc complete all as specified and directed. |
| 10 | Hacking out old broken glass (any size, thickness, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed. |
| 11 | Dismantling asbestos cement/fibre (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. Hacking out old broken glass (any size, thickness, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed. |
| 12 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed. |
| 13 | Taking down cement plaster of any description on brick walls or concrete or stone and ceilings including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 14 | Roughening surfaces of old concrete floor or roof by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed. |
| 15 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) of size not exceeding 1.5 Sqm each including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fasts, and removing from site complete all as specified and directed. |
| 16 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) of size exceeding 1.5 Sqm but not exceeding 4 Sqm each including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fasts, and removing from site complete all as specified and directed. |
| 17 | Dismantling boarding, any description, fixed in any postion with nails or screws complete all as specified and directed. |
| 18 | M&L for Lean Cement Concrete (1:5:10) type E-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete and filling in Sunken portion complete all as specified and directed. |
| 19 | M&L for Lean Cement Concrete (1:3:6) type C-0 using 10mm graded crushed stone aggregate as in filling back sides of pressed steel frames complete all as specified and directed. |
| 20 | Formwork to rough finished surfaces of chullah hoods, chajjas, troughs and similar items including edges complete all as specified and as directed. |
| 21 | M&L for brick work built in cement mortar (1:6) with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed. |
| 22 | M&L for brick work (EXCEPT BRICKS) built in cement mortar (1:6) with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed. Note:- Old seviceable tiles shall be re-used retrieved after demolition of brick work. |
| 23 | M&L for Cast-in-Situ Plain Cement Concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in bed blocks for hold fasts roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including form work complete all as specified and directed. |
| 24 | S&F Pressed steel frames made of 1.25mm thick CRCA sheet of profile 125x60mm for door and window frames with one or more rebates incl lock strike plate, shock absorbers, 20mm dia 60mm long MS conduit for housing of a drop bolt, butt hinges, hold fasts/lugs etc and treating of internal surfaces of chowkhats and hold fasts/lugs with a coat of coal tar or black paint incl hinges, hold fasts/lugs etc including making good jambs portion by providing plaster in CM 1:4 and finishes as per existing complete all as specified. |
| 25 | S&F 35mm thick factory made 2nd class hard wood (Hollock), plain framed, paneled shutters, any number of panels, panels shall be of 12mm thick BWR glade veneered particle board medium density, wood particle board with commercial face veneers, size of members as specified in clause 8.24 (a) of MES Schedule Part-I section-8 complete all as specified and directed. |
| 26 | S&F 35 mm thick factory made 2nd class hard wood (Hollock), glazed and skeleton shutters open rebated and prepared to receive glass/ gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut and mitered beads for securing glass etc for doors, size of members as specified in clause 8.24 (a) of MES Schedule Part-I Section-8, complete all as specified and directed. |
| 27 | S&F in replacement Factory Made Box Type Steel Ventilators side / top hung with glazing bars or dovetailed or welded made of ERW tube \\"P\\"-section of size 60mmx25mm outer frame ( single rebated), comprises glazed shutter, frame of ERW tube and mild steel flat iron 2mm thick welded/screwed to frame for fixing of sheet glass including fixture and fittings like as Stopper, Cleat, Pintal hinges, holdfast etc all as shown onDrawing No. CEJZ/TD-1019/08 and CEJZ/TD-1020/08 Sheet No. 1/3 to 3/3 including taking down of old existing window complete all as specified and directed:- Note : 1. Grills and guard bars, Sheet glass and wiremesh shall be measured and paid separately. 2. Making good dismantled portion in PCC 1:2:4 type B-1 for hold fasts (four Nos for each window). 3. Preparation of steel surfaces of ventlators and applying one one shop coat of zinc chromate primer and two coats of synthetic enamel paint after installtion at site. 4. Area shall be measured flat for one side only for the purpose of measurement and payment . |
| 28 | S&F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 29 | S&F 50mmx47mm size solid PVC door frame made out of 5mm plain colour PVC sheet reinforced with MS square tube, complete all as specified shown on drawing and specified and directed. |
| 30 | S&F factory made 30mm thick (style) solid panel PVC door shutter consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified shown on drawing and specified and directed. |
| 31 | S&F 18mm thick Prelaminated particle board, exterior grade, prelaminated both sides with decorative choicelaminations, flat pressed, single or three layer type with BWP type phenol formaldihide adhesive as in cup board/ ward robe shutters and shelves including 6mm thick teak wood lipping on three sides of shutters and 20mm thick on hanging side fixed with glue and headless mild steel nails and shuuters fixed with screws to timber frame work complete all as specified and directed. |
| 32 | S&F Continuous (piano) hinges 30mm width of flaps (when open) ,mild steel, bright finish or electro galvanised complete all as specified and directed. |
| 33 | S&F 100mm size Butt hinges, medium weight, cold rolled mild steel bright finish complete all as specified and directed. |
| 34 | S&F 200mm long aluminium anodised barrel tower bolts of extruded section and fixed with steel screws complete all as specified and directed. |
| 35 | S&F 150mm size aluminium door handle, extruded aluminium alloy, fabricated type complete all as specified and directed. |
| 36 | S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed. |
| 37 | S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, with 150mm overall length of cover plate fixed in floor complete all as specified and directed, |
| 38 | S&F 300mm size mild steel helical door spring ordinery rat rail rod pattern spring including roller and roller plate complete all as specified and directed, |
| 39 | S&F 100mm size hasp and staple aluminium anodised including bolt to hinge plate and fixed with screws complete all as specified and directed. |
| 40 | S&F PTMT tower bolts, 200 mm long and fixed with steel screws complete all as specified and directed. |
| 41 | S&F PTMT butt hinges,100mm long, fixed with steel screws with brass /bronze hinges pin complete all as specified and directed. |
| 42 | S&F PTMT handle 125mm long fixed with steel screws complete all as specified and directed. |
| 43 | S&F in repairs 25mm dia mild steel curtain rods,fancy type, epoxy powder coated with and including finials, bubs and brackets, stops and rollers etc. complete all as specified and directed |
| 44 | S&F Stainless Steel Wire Cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 45 | S&F in repairs Stainless Steel Wire Cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 46 | S&F 3.0mm thick, plain sheet glass, ordinary quality and glazing, with oil putty or with wooden beads (supplied alongwith shutters), in squares n.exc 0.50 Sqm in each pane complete all as specified and directed. |
| 47 | M&L for 75mm thick Plain Cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate as in plinth protection, surfaces finished even and smooth without using extra cement as in plinth protection including provision of construction joints and expansion joints filled with bitumen mixed with sand in ratio (1:1) complete all as specified and directed. |
| 48 | M&L for 25mm thick Plain Cement Concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in surface finished rough to receive floor topping, surface finished even and fair complete all as specified and directed. |
| 49 | M&L for Machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed. |
| 50 | M&L for Machine cut kota stone slab 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab, in vertical surfaces such as skirtings, dados, risers and steps etc including rubbing and polishing complete over and including 10mm thick screed bed or bedding layer in cement mortar (1:4) complete all as specified and directed. |
| 51 | M&L for 7 to 8 mm thick (square/ rectangular) Non-skid Ceramic Tiles coloured, premium quality, Joint-free, area of each tile exceeding 0.11Sqm but not exceeding 0.18Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed. |
| 52 | M&L for 7 to 8 mm thick (square/ rectangular) Non-skid Ceramic Coloured Tiles, Joint-free, premium quality, area of each tile exceeding 0.11Sqm but not exceeding 0.18Sqm, in vertical surfaces such as skirtings, dados, risers and steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 10mm thick rendering cement plaster in cement mortar (1:4) complete all as specified and directed. |
| 53 | M&L for 7mm thick (Area 450 x 300mm / 450x350mm/ 350x250mm/300x200mm) Glazed Ceramic Coloured Tiles, in vertical surfacesX 7 mm th set and jonnted in cement slurry and pointed in white or coloured cement in vertical surfaces such as skirtings, dados, risers and steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 10mm thick rendering cement plaster in cement mortar (1:4) complete all as specified and directed. |
| 54 | M&L for 10mm thick rendering cement plaster in cement mortar (1:6) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 55 | M&L for Flush pointing to roof tiles in cement mortar (1:3) tiles grouted finish including racking out joints complete all as specified and directed. |
| 56 | M&L for brushing neat cenebt slurry with 3 Kg of cement per square metre complete all as specified and directed. |
| 57 | M&L for 15mm thick rendering cement plaster in cement mortar (1:4) on fair faces of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 58 | M&L for 15mm thick rendering cement plaster in cement mortar (1:4) in screed bed or bedding layer on fair furfaces of brick or concrete work on roof terrace for laying Water Proofing Memeberane surfaces, mixed with water proofing complound as per manufacturer's instructionsfinished even and fair without using extra cement complete all as specified and directed. Note: WPC shall be measured and paid separately. |
| 59 | M&L for 15mm thick rendering cement plaster in cement mortar (1:3) in screed bed or bedding layer or cement plater to the walls and floor of sunken portion, mixed with water proofing complound as per manufacturer's instructionsfinished even and fair without using extra cement complete all as specified and directed. Note: WPC shall be measured and paid separately. |
| 60 | M&L for 5mm thick rendering cement plaster in cement mortar (1:3) on ceiling surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 61 | Supply only Integral water proofing compound complete all as specified and directed. |
| 62 | M&L for water proofing treatment to sunken floors of Kitchen, toilets, laboratories, bath and WC's etc shall be as under :- (i) Application of two components of Acrylic modified Cementitious coating(aa) Clean the RCC Surface with wire brush and chisel out and mortar sticking to Surface(ab) Apply FOSROC NITOPROOF 600 PF (min 0.8mm dft) over a priming coat of NITOPROOF WB Primer or equivalent of ASIAN PAINT/SIKA/BERGER/PIDILITE DR FIXIT(ac) Provide HDPE 1.0mm thick Sheet before laying of any floor finishes. |
| 63 | M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.20 kg per sqm over a coat of bitumen primer @ 0.30 litre per Sqm including preparation of roof surfaces/ sunken portion and all surfaces of sunken portion complete all as specified and directed. |
| 64 | M&L for One layer of APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surfaceby forced application complete all as specified. Polymeric membrane shall be taken to a height of 60 cm (minimum) and then inserted inside the groove of parapet walls and shall be finished by a membrane flashing.Note: (i) Laying of APP based membranes shall be done by torch on method or as per manufacturer's instructions.(ii) A minimum overlap shall be 75mm length wise and 100 mm width wise of polymeric membranes respectively and sealed all overlaps and joints as manufacturer's instructions. |
| 65 | M&L for preparation of surfaces of platered, brick, concrete, polymeric etc, of any description, over10cm in width or girth,not otherwise describedone and applying two coats of Solar Reflective Bituminous Aluminium paint @0.1 Kg/ Sqm over APP Membrane complete all as specified and directed. |
| 66 | S&F 1.00mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap jointswith riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed. |
| 67 | S&F 3.15mm dia plain mild steel wire, galvanised class 3 as for mosquito nets and fixing to straining bolts, hooks, eyes, etcincluding straining and fixing to wood, concrete or steel posts and/or to straining bolts, including securing with and provision of galvanised iron tying wire, galvanised iron staples or steel pins, etc. as directed (each line of wire to be measured) complete all as specified and directed. |
| 68 | S&F 0.50mm thick Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw complete all as specified complete all as specified and directed. |
| 69 | M&L for preparing new plastered surfaces of walls and distempering with two coats of distemper oil emulsion white or tinted over one coat of cement primer over 01mm thick plaster of paris putty to prepare surface even and smooth complete all as directed. |
| 70 | M&L for preparing new plastered surfaces of walls and distempering with two coats of cement base paint over one coat of alkali resistant cement primer complete all as specified and directed. |
| 71 | M&L for complete removal of existing treatment on walls and distempering with two coats of cement base paint over one coat of alkali resistant cement primer complete all as specified and directed. |
| 72 | M&L for complete removal of existing treatment on walls and distempering with two coats of distemper oil emulsion white or tinted over one coat of cement primer over 1mm thick plaster of paris putty to prepare surface even and smooth complete all as directed. |
| 73 | M&L for Complete removal of existing treatment on wall / ceiling surfaces, including cornices, pilasters, etc, by scrapping down with wire brushes or mechanically and removing existing loose finishes, loose paricles with brooming, dusting & finally washing with water to clean the surface absolutely free from any kind of existing finishes & foreign materials, making good minor surface imperfections such as holes, dents cracks etc in cement mortar (1:3) and applying two coats of Exterior Acrylic Emulsion weather proof paint white or tinted over a coat of cenet primer complete all as specified and directed. (Note:- Weatherproof painting shall be got executed through authorised applicator of the manufacturer) |
| 74 | M&L for preparing new plastered surfaces of ceiling and applying three coats of lime white wash complete all as specified and directed. |
| 75 | M&L for preparing old surfaces decorated plastered or unplastered surfaces of walls and applying two coats of lime white wash complete all as specified and directed. |
| 76 | M&L for preparing old plastered surfaces of ceiling and applying one coat of lime white wash complete all as specified and directed. |
| 77 | M&L for preparation of new wood or wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed. |
| 78 | M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer zinc chromate complete all as specified and directed. |
| 79 | M&L for preparation of old wood or wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint over one coat of pink primer complete all as specified and directed. |
| 80 | M&L for preparation of old steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 81 | S&F 75mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to walls or floors complete all as specified and directed. Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 82 | S&F 110mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches complete all as specified and directed.Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 83 | S&F 110mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to walls or floor complete all as specified and directed.Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 84 | S&F 75mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches complete all as specified and directed.Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 85 | S&F 75mm dia PVC (SWR) bends any radius complete all as specified and directed. |
| 86 | S&F 110mm dia PVC (SWR) bends any radius complete all as specified and directed. |
| 87 | S&F 110mm dia PVC (SWR) bends any radius with oval type access door complete all as specified and directed. |
| 88 | S&F 100mm dia PVC (SWR) Branch piece double (double \\"Y\\") equal or unequal complete all as specified and directed. |
| 89 | S&F 75mm dia PVC (SWR)Junction single (single or double \\"T\\") equal or unequal complete all as specified and directed. |
| 90 | S&F 110mm dia PVC (SWR)Junction single (single or double T) equal or unequal complete all as specified and directed. |
| 91 | S&F 110mm dia PVC (SWR) vent cowl complete all as specified and directed. |
| 92 | S&F 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 93 | S&F 15mm bore Galvanised Medium Grade Steel Water Tubing with all fittings and connections fixed complete to walls and celling or laid in floor, complete all as specified and directed. |
| 94 | S&F 20mm bore Galvanised Medium Grade Steel Water Tubing with all fittings and connections fixed complete to walls and celling or laid in floor, complete all as specified and directed. |
| 95 | S&F in repairs Two Way brass CP Bibcock with wall flange 50 to 65mm long (facilitate to fix the Halth faucet) (Make:Jaquar) CQTNO;23041/FLR 8041N) and Make: CERA catNo:F3002161 /F2002161 15 mm dia bore type with handle, screwed down, screwed for iron pipe or famale of quarter turn type complete all as specified and directed. |
| 96 | S&F in repairs 15mm bore Bib Taps, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 97 | S&F 15mm bore Bib Taps, long body fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 98 | S&F in repairs 15mm bore fancy type, chromium plated, Stop valves, cast copper alloy, with long shank and cup concealed type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 99 | S&F 15mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes complete all as specified and directed. |
| 100 | S&F 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes complete all as specified and directed. |
| 101 | S&F 15mm bore Pillar Taps, fancy type, chromium plated, cast copper alloy, with capstan heads, screwed down high pressure, with or without lettered 'HOT' or 'COLD' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed. |
| 102 | S&F in repair push tap 15 mm bore any colour of PTMT suitable for urinals screwed for iron pipe and fixed(minimum weight 15mm-47 gms) complete all as specified and directed. |
| 103 | S&F 32mm bore PVC waste pipe of suitable length to waste coupling pipe attached with rubber ring joints/ PVC threaded cup, fixed to waste coupling of sinks / WHBs/urinal of required length complete all as specified and directed. |
| 104 | S&F 32mm bore Waste fittings of chromium plated brass p for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed. |
| 105 | S&F 15mm PVC connections 450mm long heavy duty with brass nuts adaptors and washers and rubber gaskets at both ends complete all as specified and directed. |
| 106 | S&F 15mm bore Angle Valves, fancy type, chromium plated, cast copper alloy, with flange, one way turn, screwed down high pressure, with crutch or butterfly handle, screwed for iron pipe complete all as specified and directed. |
| 107 | S&F in replacement 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), three layered, ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including 20mm dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule hoisted and fixed including dismentling and taking down old unserviceable water tank capacity 1000 litres complete as specified in SSR Part-I. complete all as specified and directed. |
| 108 | S&F in repair 20 mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic float ball screwed for iron pipe complete all as specified and directed. |
| 109 | S&F in repairs Wash Hand Basins, Vitreous China (flat back) white of size 550mm X 400mm including cutting for and pinning in ends of brackets or erecting stand including waste fittings, 32 mm bore PVC flush pipe with long screwed shucks and fly nuts and including PVC discharge pipe complete all as specified and directed. |
| 110 | S&F in repairs Vitreous China Squatting Pan, \\"Orissa pattern\\", size 580x440mm white/ coloured with integral foot rests (excluding flushing cistern, flush pipe and waste pipe), including trap and connection to trap, and to flushing pipe, anti-syphonage pipe, etc.complete including all joints and making good to floors complete all as specified and directed. |
| 111 | S&F in repairs Vitreous China Wash Down Water Closet Pan (pedestal pattern) complete, white/ coloured including seat and cover, trap, including connection to drain (or outgoing pipe), and to flushing pipe, anti-syphonage pipe, etc. etc.complete including all joints and making good to floors complete all as specified and directed. |
| 112 | S&F in repairs Vitreous China urinals, half stall (back or corner wall type) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete including all joints and making good to floors complete all as specified and directed. |
| 113 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25m long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified complete all as specified and directed. |
| 114 | S&F pressire jet chromium plated brass with flexible PVC pipe of requred lenghth with brass adaptor nut with washer complete all as specified and directed. |
| 115 | S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms)complete all as specified and directed. |
| 116 | S&F in repairs 10 litres capacity low level PVC valveless syphonic action type flushing cistern with inlet ball valve, float and handle including brackets complete all as specified and directed. |
| 117 | S&F in repairs 125mm dia Chromium plated brass shower rose with swivel joints, any colour including shower arm 15mm dia, 195mm long with bend of 45 degree with flange of chromium plated brass including fixing complete to steel pipe or union complete all as specified and directed. |
| 118 | S&F Stainless Steel (AISI-304) Shower drain with Cockroach Trap (450 x 75mm) heavy duty including all fittings and fixed with white cement fixed complete all as specified and directed |
| 119 | S&F in repirs 600mmx450mm size of specified thickness looking mirror, bevelled edge of selected quality glass with aluminium frame made of channel around, mounted on 6mm thick commercial ply or AC building board, fitted to wooden plug with chromiumplated brass screws and cup washers complete all as specified and directed. |
| 120 | S&F in repairs tubular Towel Rail 20mm dia brass chromium plated 600mm long between flanges type \\"D\\", with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms)complete all as specified and as directed. |
| 121 | S&F in repairs chromium plated steel soap dish not less than 1mm thickness fixed with chromium plated steel screws and PVC gutties complete all as specified and directed. |
| 122 | Excavating in trenches, in soft/loose soil, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cables and pipes etc. not exceeding 10Sqm on plan and not exceeding 1.5m in depth and getting out complete all as specified and as direcetd. |
| 123 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceding 25cm in soft/loose soil complete all as directed. |
| 124 | Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 125 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 126 | M&L for point wiring with PVC insulated unsheathed single core FRLSH multistranded copper conductor cable IS-694 marked of size 1.5 Sqmm (nominal area) in and including 20mm dia non metallic rigid PVC conduit with all accessories if require such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards / round blocks(for housing lamp holders and light fittings etc) and existing mild steel pressed / cast iron sunken boxes of suitable size for mounting switches / bell pushes / sockets, fan regulator etc covered with new 3 mm thick laminated bakelite sheet top cover including continuous earth wire cable of size 1.5 Sqmm unsheated stranded copper conductor with green PVC FRLSH insulation connected to common earth dolly complete all as specified and directed for One light/fan/Bell Point controlled by one single pole one way switch. Note:- Cutting chases for conduits and sunken boxes and making good to walls, floors etc, in case of recessed and concealed conduit wiring are included in item of taking down point wiring carefully. |
| 127 | ditto all as per item No 126 but for one socket outlet on the same board controlled by one single pole one way switch |
| 128 | ditto all as per item No 126 but for one 5 amps socket outlet independent controlled by one single pole 5 Amp switch. |
| 129 | M&L for point wiring with PVC insulated unsheathed single core FRLSH multistranded copper conductor cable IS-694 marked of size 2.5 Sqmm (nominal area) in and including non metallic rigid PVC conduit with all accessories if require such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards / round blocks(for housing lamp holders and light fittings etc) and existing mild steel pressed / cast iron sunken boxes of suitable size for mounting switches / bell pushes / sockets, fan regulator etc covered with new 3 mm thick laminated bakelite sheet top cover including continuous earth wire cable of size 2.5 Sqmm unsheated stranded copper conductor with green PVC FRLSH insulation connected to common earth dolly complete all as specified and directed for one 3/5 pin 15 Amps switch socket out let on the independent board controlled by one single pole one way switch. Note:- Cutting chases for conduits and sunken boxes and making good to walls, floors etc, in case of recessed and concealed conduit wiring are included in item of taking down point wiring carefully. |
| 130 | M&L for point wiring with PVC insulated unsheathed single core FRLSH multistranded copper conductor cable IS-694 marked of size 4.0 Sqmm (nominal area) in and including non metallic rigid PVC conduit with all accessories if require such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards / round blocks(for housing lamp holders and light fittings etc) and existing mild steel pressed / cast iron sunken boxes of suitable size for mounting switches / bell pushes / sockets, fan regulator etc covered with new 3 mm thick laminated bakelite sheet top cover including continuous earth wire cable of size 4.0 Sqmm unsheated stranded copper conductor with green PVC FRLSH insulation connected to common earth dolly complete all as specified and directed for one 3/5 pin 15 Amps switch socket out let on the independent board controlled by one single pole one way switch. Note:- Cutting chases for conduits and sunken boxes and making good to walls, floors etc, in case of recessed and concealed conduit wiring are included in item of taking down point wiring carefully. |
| 131 | S & F Modular Switch one way 6 A, 1 module complete all as specified and directed. Make - Precision/Anchor/Havells/Legrand |
| 132 | S & F Modular Switch one way 16 A, 1 module complete all as specified and directed. Make - Precision/Anchor/Havells/Legrand |
| 133 | S & F Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed. Make - Precision/Anchor/Havells/Legrand |
| 134 | S & F Modular Socket, 6A/16A - 2/3 pin combined 2 module complete all as specified and directed. Make - Precision/Anchor/Havells/Legrand |
| 135 | S & F Modular white cover plate including GI box inner, 3 module complete all as specified & directed. Make : Precision/Anchor/Havells/Legrand |
| 136 | S & F Modular white cover plate including GI box inner, 4 modulecomplete all as specified & directed. Make : Precision/Anchor/Havells/Legrand |
| 137 | S & F Modular white cover plate including GI box inner, 8 module complete all as specified &directed. Make : Precision/Anchor/Havells/Legrand |
| 138 | S & F Modular step type regulator,120 W - 2 module complete all as specified and directed. Make - Precision/Anchor/Havells/Legrand |
| 139 | S&F 5/6 Amp bell push flush type, one module, ISI marked complete all as specified and directed. |
| 140 | S&F 5/6 Amp Switch piano flush type single pole one way ISI Marked complete all as specified and directed. |
| 141 | S&F 15/16 Amp Switch piano flush type single pole one way ISI Marked complete all as specified and directed. |
| 142 | S&F 5/6 Amp Socket outlet 2 in1, 3 pin flush type ISI marked complete all as specified and directed. |
| 143 | S&F 15/16 Amp Socket outlet 2 in 1, 3 pin flush type ISI marked complete all as specified and directed. |
| 144 | S&F 5/6 Amp Switch piano flush type single pole one way ISI Marked complete all as specified and directed. |
| 145 | S&F 15/16 Amp Switch piano flush type single pole one way ISI Marked complete all as specified and directed. |
| 146 | S&F 5/6 Amp Socket outlet 2 in1, 3 pin flush type ISI marked complete all as specified and directed. |
| 147 | S&F 15/16 Amp Socket outlet 2 in 1, 3 pin flush type ISI marked complete all as specified and directed. |
| 148 | S&F 5/6 Amp bell push flush type ISI marked complete all as specified and directed. |
| 149 | S&F Ceiling Roses Ceiling rose, 3 phase/PVC/polycarbonate, isolated body omplete all as specified and directed. |
| 150 | S&F Lamp holder PVC/Polycarbonate,isolated with back plate suitable for batten fittings ISI marked complete all as specified and directed. including 10W LED Bulb omplete all as specified and directed. |
| 151 | S&F bell, Ding Dong AC. 230 Volts, single pole complete all as specified and directed. |
| 152 | S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified and directed. |
| 153 | S&F 300mm sweep Exhaust Fan, steel body AC single Phase. 230V with blades and frame and louvers with Copper winding including cutting holes/ opening, grouting bolts, fixing with nuts and washers and making good in cement mortar (1:4) and finshing surfcae to match with existing surfaces complete all as specified and directed. |
| 154 | S&F 450mm sweep Exhaust Fan, steel body AC single Phase. 230V, 900 RPM with blades and frame and louvers with Copper winding including cutting holes/ opening, grouting bolts (12mm dia and 15cm long) , fixing with nuts and washers, making connection wih copper onductor PVC flexible twin wire of size 23/0.0076 and including citting holes and making good in cement mortar (1:4) and finshing surfcae to match with existing surfaces complete all as specified and directed. |
| 155 | S&F 300mm sweep Exhaust Fan, sturdy Engineering plastic body with louvers AC single Phase. 230V with blades and frame and louvers with Copper winding complete all as specified and directed. |
| 156 | Supply, hoist, fix and connect Ceiling Fan complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 157 | Hoist, fix and connect old serviceable Ceiling Fan complete with blades, down rods, electronic regulator and accessories, 230 V, any sweep, size and type, at height 3 to 5m of the building including making connection with copper onductor PVC flexible twin wire of size 23/0.0076 complete all as specified and directed. (Note:- Ceiling fans taken down during taking down point wiring shall be refixed under this item) |
| 158 | S&F LED tube light fitting 1 X 18 W decorative ultra slim linear LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient 230V, complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. Cat Part No. LHEXBLP7UN1W018 of Make - Havells or equivalent as specified in Appendix \\"B\\" of Particular Specfications, complete all as specified and directed.. |
| 159 | S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver threecore flexible copper conductor cases of suitable size complete all as specified and directed. |
| 160 | S&F LED Mirror light 7/9/18 Watt 2 ft adjustable type enegy saving curve type t as specified in Appendix \\"B\\" of Particular Specfications, complete all as specified and directed. |
| 161 | S&F LED bulb 9/10 Watt B-22, 65000K, pin type complete all as specified and directed. |
| 162 | S&F LED tube light fitting 20 Watt 4 feet long decorative ultra slim linear LED lighting three colour CCT Change LED Batten Which can change the Colour of batten FROM WHARM WHITE TO natural white to cool whitewhite the help of a simple toggle switch, fixture with extruded polycarbonate,environmental friendly, energy efficient 230V, complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 163 | S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impactand corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. complete all as specified and directed. |
| 164 | S&F sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series pre-wired VTPN DBs (Verticle type)fitted wit ABS frame, 415 Volts 200Amps rated bus bar,Neutral link,Earth bar and Din rail, 4 ways dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified. |
| 165 | S&F sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series pre-wired TPN DBs (Verticle type)fitted wit ABS frame, 415 Volts 200Amps rated bus bar,Neutral link,Earth bar and Din rail, 4 ways dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified. |
| 166 | S&F in repairs sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series pre-wired SPN DBs, 240 Volts 200 Amps rated bus bar,Neutral link,Earth bar and Din rail, 8 ways dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified. |
| 167 | S&F sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series pre-wired SPN DBs, 240 Volts 200 Amps rated bus bar,Neutral link,Earth bar and Din rail, 4 ways dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified. |
| 168 | S&F Moulded Case Circuit Breaker (MCCB) Four Poles (FP) current carrying capacity 100Amp, 415 Volts, breaking capacity 16 KA with adjustable thermal and magnetic settings, complete all as specified and directed. |
| 169 | S&F Miniature Circuit Breaker (MCB) Single Pole (SP) current carrying capacity 6 to 32 Amp, 240V, breaking capacity 10 KA, type 'B' curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 170 | S&F Miniature Circuit Breaker (MCB) Single Pole (SP) current carrying capacity 40Amp, 240V, breaking capacity 10 KA, type 'B' curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 171 | S&F Miniature Circuit Breaker (MCB) Single Pole and Neutral (SPN) current carrying capacity 32 Amp, 240V, breaking capacity 10 KA, type 'C' curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 172 | S&F Miniature Circuit Breaker (MCB) Single Pole and Neutral (SPN) current carrying capacity 40 to 63Amp, 240V, breaking capacity 10 KA, type 'C' curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 173 | S&F Single Pole two Pin and Earth Plug and Socket including one single pole MCB 20 Amp fixed in sheet Metal enclosures complete all as specified and directed. |
| 174 | M&L for submain wiring with two single core PVC insulated FRLSH cable with Copper conductor unsheathed cable of size 4.0Sqmm drawn through in and including 25mm dia non metallic rigid PVC conduit with all accessories including one 4.0Sqmm PVC insulated FRLSH cable with Copper conductor unsheathed cable single core for continuous earthing complete all as specified and directed. ( Note : Two run of single core PVC insulated cable with Copper conductor unsheathed cable of size 4.0Sqmm and one run of 4.0Sqmm PVC insulated copper conductor single core (2x4.0Sqmm+1x4.0Sqmm earth wire) and one run of PVC conduit shall be measured as single run) |
| 175 | S&F in repairs submain wiring with two single core PVC insulated FRLSH cable with Copper conductor unsheathed cable of size 6.0Sqmm drawn through in and including 25mm dia non metallic rigid PVC conduit with all accessories including one 6.0Sqmm PVC insulated FRLSH cable with Copper conductor unsheathed cable single core for continuous earthing including taking down existing submain wiring and conduits etc complete all as specified and directed. ( Note : Two run of single core PVC insulated cable with Copper conductor unsheathed cable of size 6.0Sqmm and one run of 6.0Sqmm PVC insulated copper conductor single core (2x6.0Sqmm+1x6.0Sqmm earth wire) and one run of PVC conduit shall be measured as single run) |
| 176 | Supply, lay, test, joint and commission LT XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric powercable heavy duty with aluminium conductor of size cross sectional area 35 Sqmm x 3.2 core, 1100 Volts grade (1.1 KV earthed system); laid in trenches/under floor/through ducts, fixed on pole complete all as specified and directed. Note:- Excavation & Earth work, sand cushioning, cable protection cover, pipe shall be measured and paid separately under respective items of BoQ. |
| 177 | Supply, lay, test, joint and commission LT XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric powercable heavy duty with aluminium conductor of size cross sectional area 25 Sqmm x 4 core, 1100 Volts grade (1.1 KV earthed system); laid in trenches/under floor/through ducts, on Hill / fixed on pole complete all as specified and directed. Note:- Excavation & Earth work, sand cushioning, cable protection cover, pipe shall be measured and paid separately under respective items of BoQ. |
| 178 | Supply and lay 50mm bore galvanised pipe light grade of ISI marked for passing of cable fixed to poles/walls/laid under floor/ laid in trenches as cable protection complete with and including fittings as required compete all as specified and directed.Note:- Excavation & Earth work, sand cushioning, cable protection cover, pipe and joint shall be measured and paid separately under respective items of BoQ. |
| 179 | M&L for Sand cushioning using sand suitable for plaster works to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep punned to 10cm after laying and stretching the cable complete all as specified and directed. Note : 18 cm punned thickness shall be measured and paid. |
| 180 | Supply and lay cable protection cover with Bricks; common burnt clay building bricks, sub-class ‘B’ designation 75, (size 23cmx11.5cmx7.5cm) putting accross the cable with width of protection cover equal to length of brick, abutting to each other for cable protection complete all as specified and directed. |
| 181 | M&L for Earthing complete with Galvanised Iron earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at (Earth pit not less than 2.25m deep below ground level) a depth not less than 2.25m below normal ground level with top edge of earth plate at depth not less than 1.5m below normal ground level surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using 4mm dia galvanised earth wire by means of bolts, nuts, check nuts and washers of galvanized iron and protected by 15mm bore GI pipe light grade connected to main switch board or main control board and 20mm bore GI pipe light grade for watering and including funnel, wire mesh, 80mm thick pre-cast RCC (1:2:4) type B-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4Kg/Sqm in lieu of CI cover, PCC (1:2:4) type B-1 pit/chamber including all necessary excavation: and earth work, form work, disposal of surplus soil to a distance not exceeding 50m all as specified and al shown in Electrical Plate No.3 of MES Standard Schedule of Rates 2009 Part-I complete all as specified and directed.Note:- (i) The unit rate shall deemed to include for Test point, PCC pit, 4mm dia GI earth wire from top of the earth plate up to 7.5m above ground level. In case 15mm bore GIprotection pipe required is less than 7.5m, no price adjustment shall be made. (ii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junctions, elbow etc shall be deemed to be included in the unit rate.(iii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail