| 1 | Supply and fix Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including necessary hangers6mm dia GI up to1200mm length adjusting level fixed to roof slab by means of cleats made out of FI 40x3mm size 60 cm long and expansion holdfast 12.5mm dia 40mm long with and including fixing of 8mm thick Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish complete all as specified and as directed.Note: Rate is inclusieve of scaffolding and necessary safety arrangements |
| 2 | M & L for 18 mm thick Perforated particle board/ tiles for insulation and accoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or with staples on snap grid complete all as specified and directed. |
| 3 | M & L Plain fillets. square, rectangular or triangular in sectional area exc 0.13 Sq.cm but not exc 0.25 Sq.cm, clean sawn, secured with screws or brads complete all as specified and directed |
| 4 | M & L for powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 5 | M & L for powder coated anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed. |
| 6 | Supply and fixing factory made uPVC door frame made of uPVC. extruded sections having an overall dimension (extruded section profile) 42x50 mm (tolerance ± 1 mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame Jointed with galvanized brackets and stainless steel screws, jointsmitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete all as specified by the manufacturer and as per directions of Engineer-in-charge welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. Making arangement for fixing of hardware, EPDM gasket, 1.2+ 0.2 mm thick galvanized steel profile to be inserted in required profile. Frame to be fixed to wall with 8 mm x 100 mm long fasteners, all complete and directed. |
| 7 | Providing and fixing factory made uPVC white colour casement (Openable) Door made of extruded profile wilh wall thickness of 2.3mm ( + -0.2mm). Window profile with hollow section with mitlti chamber, frame (60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling ol holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall wilh 8mm x 100mm long fasteners. Hardware: [casement door handle made of zinc alloyed (white powder coated). Corner striker. Secondary Strikers. Cylinder. Door transmission gear made of mild sleel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated) [and 5mm thick glazing with selected quality glass. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured forpayment purpose.) |
| 8 | M & L for glass panel of sheet glass 5.5mm thick ordinary quality and glazing with rubber gasket exc 0.5 sqm in each pane complete all as specified and directed |
| 9 | Supply and ifx solar control film 25 micron reflective type of approved colour complete all as specified and as directed. |
| 10 | M & L for plaster of paris putty of 1 mm thickness over false ceiling surface and to prpare the surface even and smooth to receive primer complete all as specified and directed |
| 11 | M & L for two coat of oil bond distemper on partilce boards complete all as specified and directed. |
| 12 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed. |
| 13 | Taking down ceiling fan, sealing cable end,dismantling blades and removing fan and blades to store carrying to the store complete all as specified and directed. |
| 14 | Hanging only ceiling fan (M.D.supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed. |
| 15 | Taking down of Split type Air Conditioner of any capacity 1.5/2 TR from existing location incl removal of outdoor unit by opening all electrical connection and suction & discharge line connection carefully & removing materials to store for keeping in safe custody for reuse at site. Filling the opening of old location with cement mortor, applying white wash on wall with matching with existing colour of the site. Refixing, installation of Split type Air Conditioner to new location as directed by Engineer-in-charge, of any capacity 1.5/2 TR by filling of refrigerent, installation of outdoor unit, fixing of suction and discharge copper tubes with replacement of insulation of suction & discharge line and making holes for passing of suction & discharge line on brick wall incl well finish with cement mortor, applying white wash, colour wash, distemper etc on wall to match with existing colour of the adjacent surface at new location etc. complete all as specified and directed. |
| 16 | Taking down the heat/smoke detectors and refixing on false ceiling by extending armoured copper cable 2 x 1.5 sq.mm. up to a lenth of 1.5 Mtr complete all as specified and directed. |
| 17 | Taking out the sprinkler and refixing just below the false ceiling by extending ERW pipe of suitable size as per site requirement up to a length of maximum 0.5 mtr complete all as specified and directed. Please Enable Macros to View BoQ information |
| 18 | Taking out the sprinkler and refixing just below the false ceiling by extending ERW pipe of suitable size as per site requirement up to a length of maximum 0.5 mtr complete all as specified and directed. Please Enable Macros to View BoQ information |